首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
MS Binding Assays represent a label‐free alternative to radioligand binding assays. In this study, we present an LC‐ESI‐MS/MS method for the quantification of (R,R)‐4‐(2‐benzhydryloxyethyl)‐1‐(4‐fluorobenzyl)piperidin‐3‐ol [(R,R)‐D‐84, (R,R)‐ 1 ], (S,S)‐reboxetine [(S,S)‐ 2 ], and (S)‐citalopram [(S)‐ 3 ] employed as highly selective nonlabeled reporter ligands in MS Binding Assays addressing the dopamine [DAT, (R,R)‐D‐84], norepinephrine [NET, (S,S)‐reboxetine] and serotonin transporter [SERT, (S)‐citalopram], respectively. The developed LC‐ESI‐MS/MS method uses a pentafluorphenyl stationary phase in combination with a mobile phase composed of acetonitrile and ammonium formate buffer for chromatography and a triple quadrupole mass spectrometer in the multiple reaction monitoring mode for mass spectrometric detection. Quantification is based on deuterated derivatives of all three analytes serving as internal standards. The established LC‐ESI‐MS/MS method enables fast, robust, selective and highly sensitive quantification of all three reporter ligands in a single chromatographic run. The method was validated according to the Center for Drug Evaluation and Research (CDER) guideline for bioanalytical method validation regarding selectivity, accuracy, precision, calibration curve and sensitivity. Finally, filtration‐based MS Binding Assays were performed for all three monoamine transporters based on this LC‐ESI‐MS/MS quantification method as read out. The affinities determined in saturation experiments for (R,R)‐D‐84 toward hDAT, for (S,S)‐reboxetine toward hNET, and for (S)‐citalopram toward hSERT, respectively, were in good accordance with results from literature, clearly demonstrating that the established MS Binding Assays have the potential to be an efficient alternative to radioligand binding assays widely used for this purpose so far.  相似文献   

2.
Rapid, simple and reliable HPLC/UV and LC‐ESI‐MS/MS methods for the simultaneous determination of five active coumarins of Angelicae dahuricae Radix, byakangelicol (1), oxypeucedanin (2), imperatorin (3), phellopterin (4) and isoimperatorin (5) were developed and validated. The separation condition for HPLC/UV was optimized using a Develosil RPAQUEOUS C30 column using 70% acetonitrile in water as the mobile phase. This HPLC/UV method was successful for providing the baseline separation of the five coumarins with no interfering peaks detected in the 70% ethanol extract of Angelicae dahuricae Radix. The specific determination of the five coumarins was also accomplished by a triple quadrupole tandem mass spectrometer equipped with an electrospray ionization source (LC‐ESI‐MS/MS). Multiple reaction monitoring (MRM) in the positive mode was used to enhance the selectivity of detection. The LC‐ESI‐MS/MS methods were successfully applied for the determination of the five major coumarins in Angelicae dahuricae Radix. These HPLC/UV and LC‐ESI‐MS/MS methods were validated in terms of recovery, linearity, accuracy and precision (intra‐ and inter‐day validation). Taken together, the shorter analysis time involved makes these HPLC/UV and LC‐ESI‐MS/MS methods valuable for the commercial quality control of Angelicae dahuricae Radix extracts and its pharmaceutical preparations. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

3.
This study is the first to detail the development and validation of a rapid, sensitive and specific LC‐ESI‐MS/MS method for the determination of eriodictyol‐8‐C‐β‐d ‐glucopyranoside (EG) in rat plasma. A simple protein precipitation method was used for plasma sample preparation. Chromatographic separation was successfully achieved on an Agilent Zorbax XDB C18 column (2.1 × 50 mm, 3.5 µm) using a step gradient program with the mobile phase of 0.1% formic acid aqueous solution and acetonitrile with 0.1% formic acid. EG and the internal standard (IS) were detected using an electrospray negative ionization mass spectrometry in the multiple reaction monitoring mode. This method demonstrated good linearity and did not show any endogenous interference with the active compound and IS peaks. The lower limit of quantification of EG was 0.20 ng/mL in 50 μL rat plasma. The average recoveries of EG and IS from rat plasma were both above 80%. The inter‐day precisions (relative standard deviation) of EG determined over 5 days were all within 15%. The present method was successfully applied to a quantification and bioavailability study of EG in rats after intravenous and oral administration. The oral absolute bioavailability of EG in rats was estimated to be 7.71 ± 1.52%. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

4.
Lipopeptide biosurfactants produced by the Bacillus licheniformis V9T14 strain showed an interesting anti‐adhesion activity against biofilm formation of human pathogenic bacterial strains. The chemical characterisation of the crude extract of V9T14 strain was first developed through electrospray ionisation mass spectrometry (ESI‐MS) and ESI‐MS/MS direct infusions: two sets of molecular ion species belonging to the fengycin and surfactin families were revealed and their structures defined, interpreting their product ion spectra. The LC/ESI‐MS analysis of the crude extract allowed to separate in different chromatogram ranges the homologues and the isoforms of the two lipopeptide families. The extract was then fractionated by silica gel chromatography in two main fractions, I and II. The purified biosurfactants were analysed through a new, rapid and suitable LC/ESI‐MS/MS method, which allowed characterising the composition and the structures of the produced lipopeptides. LC/ESI‐MS/MS analysis of fraction I showed the presence of C13, C14 and C15 surfactin homologues, whose structures were confirmed by the product ion spectra of the sodiated molecules [M + Na]+ at m/z 1030, 1044 and 1058. LC/ESI‐MS/MS analysis of fraction II confirmed the presence of two main fengycin isoforms, with the protonated molecules [M + H]+ at m/z 1478 and 1506 corresponding to C17 fengycin A and C17 fengycin B, respectively. Other homologues (C14 to C16) were revealed and confirmed as belonging to fengycin A or B according to the retention times and the product ions generated, although with the same nominal mass. Finally, a relative percentage content of each homologue for both lipopeptides families in the whole extract was proposed. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

5.
A rapid and sensitive LC–MS/MS method with good accuracy and precision was developed and validated for the pharmacokinetic study of quercetin‐3‐O‐β‐d ‐glucopyranosyl‐7‐O‐β‐d ‐gentiobioside (QGG) in Sprague–Dawley rats. Plasma samples were simply precipitated by methanol and then analyzed by LC–MS/MS. A Venusil® ASB C18 column (2.1 × 50 mm, i.d. 5 μm) was used for separation, with methanol–water (50:50, v/v) as the mobile phase at a flow rate of 300 μL/min. The optimized mass transition ion‐pairs (m/z) for quantitation were 787.3/301.3 for QGG, and 725.3/293.3 for internal standard. The linear range was 7.32–1830 ng/mL with an average correlation coefficient of 0.9992, and the limit of quantification was 7.32 ng/mL. The intra‐ and inter‐day precision and accuracy were less than ±15%. At low, medium and high quality control concentrations, the recovery and matrix effect of the analyte and IS were in the range of 89.06–92.43 and 88.58–97.62%, respectively. The method was applied for the pharmacokinetic study of QGG in Sprague–Dawley rats. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

6.
Rapid, simple and reliable HPLC/DAD and LC‐ESI‐MS methods for the simultaneous determination of baicalin and forsythin in the traditional Chinese medicinal preparation Shuanghuanglian oral liquid were described and validated. The separation condition for HPLC/DAD was optimized using a BDS hypersil C18 column (Thermo, 2.1 × 150 mm, particle size 5 μm) by gradient elution using methanol‐0.2 % ammonium acetate as the mobile phase. The suitable detection wavelength was set at 277 nm for the quantitative analysis of baicalin and forsythin in this method. Some operational parameters of the ESI interface were optimized, negative m/z 445[M?H]? for baicalin and negative m/z 593[M+CH3COO]? for forsythin, positive m/z 447[M+H]+ for baicalin and positive m/z 552[M+NH 4]+ for forsythin, respectively. These HPLC/DAD and LC‐ESI‐MS methods were validated in terms of recovery, linearity, accuracy and precision (intra‐ and inter‐day validation). These methods can be used as a complementary method for the commercial quality control of Shuanghuanglian oral liquid and its pharmaceutical preparations.  相似文献   

7.
A simple and sensitive liquid chromatography–electrospray ionization–tandem mass spectrometry (LC‐ESI‐MS/MS) technique was developed and validated for the determination of sibutramine and its N‐desmethyl metabolites (M1 and M2) in human plasma. After extraction with methyl t‐butyl ether, chromatographic separation of analytes in human plasma was performed using a reverse‐phase Luna C18 column with a mobile phase of acetonitrile–10 mm ammonium formate buffer (50:50, v/v) and quantified by ESI‐MS/MS detection in positive ion mode. The flow rate of the mobile phase was 200 μL/min and the retention times of sibutramine, M1, M2 and internal standard (chlorpheniramine) were 1.5, 1.4, 1.3 and 0.9 min, respectively. The calibration curves were linear over the range 0.05–20 ng/mL, for sibutramine, M1 and M2. The lower limit of quantification was 0.05 ng/mL using 500 μL of human plasma. The mean accuracy and the precision in the intra‐ and inter‐day validation for sibutramine, M1 and M2 were acceptable. This LC‐MS/MS method showed improved sensitivity and a short run time for the quantification of sibutramine and its two active metabolites in plasma. The validated method was successfully applied to a pharmacokinetic study in human. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

8.
A sensitive and reliable liquid chromatography tandem mass spectrometry (LC–MS/MS) method was developed to determine cyanidin‐3‐O‐glucoside (Cy‐3G) in normal and streptozotocin‐induced diabetic rat plasma. Chromatographic separation was carried out on a Zorbax SB‐C18 (50 × 4.6 mm, 5 μm) column and mass spectrometric analysis was performed using a Thermo Finnigan TSQ Quantum Ultra triple‐quadrupole mass spectrometer coupled with an ESI source in the negative ion mode. Selected reaction monitoring mode was applied for quantification using target fragment ions m/z 447.3 → 285.2 for Cy‐3G and m/z 463.0 → 300.1 for quercetin‐3‐O‐glucoside (internal standard). The calibration curve was linear over the range 3.00–2700 ng/mL (r2 ≥ 0.99) with the lower limit of quantitation at 3.00 ng/mL. Intra‐ and inter‐day precision was <14.5% and mean accuracy was from −11.5 to 13.6%. Stability testing showed that Cy‐3G remained stable during the whole analytical procedure. After validation, the assay was successfully used to support a preclinical pharmacokinetic comparison of Cy‐3G between normal and diabetic rats. Results indicated that diabetes mellitus significantly altered the in vivo pharmacokinetic characteristics of Cy‐3G after oral administration in rats.  相似文献   

9.
Vitamin D deficiency in an infant is associated with a wide range of adverse health outcomes in later life. A method for the quantification of 25‐hydroxyvitamin D3 [25(OH)D3, the best‐established indicator of vitamin D status] in neonatal dried blood spots (DBSs) using LC/ESI‐MS/MS has been developed and validated. The method employed two steps of derivatization, a Diels–Alder reaction with 4‐phenyl‐1,2,4‐triazoline‐3,5‐dione followed by acetylation, to enhance the detectability of 25(OH)D3 in ESI‐MS/MS and to separate 25(OH)D3 from 3‐epi‐25‐hydroxyvitamin D3 [3‐epi‐25(OH)D3], a potent interfering metabolite. 25(OH)D3 was extracted from two DBS punches (3 mm in diameter, equivalent to 5.3 μL of whole blood), purified using an Oasis HLB® cartridge, and subjected to derivatization prior to analysis with LC/ESI‐MS/MS. 25‐Hydroxyvitamin D4 was used as the internal standard. This method was reproducible (intra‐ and inter‐assay RSDs, <6.9%) and accurate (analytical recovery, 95.2–102.7%), and the LOQ was 3.0 ng/mL. The developed method enabled specific quantification of 25(OH)D3 in neonatal DBSs and detection of vitamin D deficiency without interference from 3‐epi‐25(OH)D3.  相似文献   

10.
Methylation is one of the important posttranslational modifications of biological systems. At the metabolite level, the methylation process is expected to convert bioactive compounds such as amino acids, fatty acids, lipids, sugars, and other organic acids into their methylated forms. A few of the methylated amino acids are identified and have been proved as potential biomarkers for several metabolic disorders by using mass spectrometry–based metabolomics workstation. As it is possible to encounter all the N‐methyl forms of the proteinogenic amino acids in plant/biological systems, it is essential to have analytical data of all N‐methyl amino acids for their detection and identification. In earlier studies, we have reported the ESI‐MS/MS data of all methylated proteinogenic amino acids, except that of mono‐N‐methyl amino acids. In this study, the N‐methyl amino acids of all the amino acids ( 1 ‐ 21 ; including one isomeric pair) were synthesized and characterized by ESI‐MS/MS, LC/MS/MS, and HRMS. These data could be useful for detection and identification of N‐methyl amino acids in biological systems for future metabolomics studies. The MS/MS spectra of [M + H]+ ions of most N‐methyl amino acids showed respective immonium ions by the loss of (H2O, CO). The other most common product ions detected were [MH‐(NH2CH3]+, [MH‐(RH)]+ (where R = side chain group) ions, and the selective structure indicative product ions due to side chain and N‐methyl group. The isomeric/isobaric N‐methyl amino acids could easily be differentiated by their distinct MS/MS spectra. Further, the MS/MS of immonium ions inferred side chain structure and methyl group on α‐nitrogen of the N‐methyl amino acids.  相似文献   

11.
A simple, specific, sensitive and rapid LC‐ESI‐MS/MS method has been developed and validated for the quantification of 4‐methylpyrazole in dog plasma using N‐methylnicotinamide‐d4 as an internal standard (IS) as per regulatory guidelines. Sample preparation was accomplished through a simple protein precipitation. Chromatographic separation of 4‐methylpyrazole and the IS was performed on a monolithic (Chromolith RP18e) column using an isocratic mobile phase comprising 0.2% formic acid in water and acetonitrile (20:80, v/v) at a flow rate of 1.0 mL/min. Elution of 4‐methylpyrazole and the IS occurred at ~1.60 and 1.56 min, respectively. The total chromatographic run time was 3.2 min. A linear response function was established in the concentration range of 4.96–4955 ng/mL. The intra‐ and inter‐day accuracy and precision were in the ranges 1.81–12.9 and 3.80–11.1%, respectively. This novel method has been applied to a pharmacokinetic study in dogs.  相似文献   

12.
A simple, sensitive and specific high‐performance liquid chromatography mass spectrometry (LC‐MS/MS) method was developed and validated for the quantification of β‐hydroxy‐β‐methyl butyrate (HMB) in small volumes of rat plasma using warfarin as an internal standard (IS). The API‐4000 LC‐MS/MS was operated under the multiple reaction‐monitoring mode using the electrospray ionization technique. A simple liquid–liquid extraction process was used to extract HMB and IS from rat plasma. The total run time was 3 min and the elution of HMB and IS occurred at 1.48 and 1.75 min respectively; this was achieved with a mobile phase consisting of 0.1% formic acid in a water–acetonitrile mixture (15:85, v/v) at a flow rate of 1.0 mL/min on a Agilent Eclipse XDB C8 (150 × 4.6, 5 µm) column. The developed method was validated in rat plasma with a lower limit of quantitation of 30.0 ng/mL for HMB. A linear response function was established for the range of concentrations 30–4600 ng/mL (r > 0.998) for HMB. The intra‐ and inter‐day precision values for HMB were acceptable as per Food and Drug Administration guidelines. HMB was stable in the battery of stability studies, viz. bench‐top, autosampler freeze–thaw cycles and long‐term stability for 30 days in plasma. The developed assay method was applied to a bioavailability study in rats. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

13.
Melatonin (MEL) and its chemical precursor N‐acetylserotonin (NAS) are believed to be potential biomarkers for sleep‐related disorders. Measurement of these compounds, however, has proven to be difficult due to their low circulating levels, especially that of NAS. Few methods offer the sensitivity, specificity and dynamic range needed to monitor MEL and its precursors and metabolites in small blood samples, such as those obtained from pediatric patients. In support of our ongoing study to determine the safety, tolerability and PK dosing strategies for MEL in treating insomnia in children with autism spectrum disorder, two highly sensitive LC‐MS/MS assays were developed for the quantitation of MEL and precursor NAS at pg/mL levels in small volumes of human plasma. A validated electrospray ionization (ESI) method was used to quantitate high levels of MEL in PK studies, and a validated nanospray (nESI) method was developed for quantitation of MEL and NAS at endogenous levels. In both assays, plasma samples were processed by centrifugal membrane dialysis after addition of stable isotopic internal standards, and the components were separated by either conventional LC using a Waters SymmetryShield RP18 column (2.1 × 100 mm, 3.5 µm) or on a polyimide‐coated, fused‐silica capillary self‐packed with 17 cm AquaC18 (3 µm, 125 Å). Quantitation was done using the SRM transitions m/z 233 → 174 and m/z 219 → 160 for MEL and NAS, respectively. The analytical response ratio versus concentration curves were linear for MEL (nanoflow LC: 11.7–1165 pg/mL, LC: 1165–116500 pg/mL) and for NAS (nanoflow LC: 11.0–1095 pg/mL). Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

14.
A sensitive and specific LC–MS/MS assay for determination of β ‐eudesmol in rat plasma was developed and validated. After liquid–liquid extraction with ethyl ether , the analyte and IS were separated on a Capcell Pak C18 column (50 × 2.0 mm, 5 μm) by isocratic elution with acetonitrile—water–formic acid (77.5:22.5:0.1, v /v/v) as the mobile phase at a flow rate of 0.4 mL/min. An ESI source was applied and operated in positive ion mode; a selected reaction monitoring scan was used for quantification by monitoring the precursor–product ion transitions of m/z 245.1 → 163.1 for β ‐eudesmol and m/z 273.4 → 81.2 for IS. Good linearity was observed in the concentration range of 3–900 ng/mL for β ‐eudesmol in rat plasma. Intra‐ and inter‐day precision and accuracy were both within ±14.3%. This method was applied for pharmacokinetic studies after intravenous bolus of 2.0 mg/kg or intragastric administration of 50 mg/kg β ‐eudesmol in rats.  相似文献   

15.
A highly sensitive and selective on‐line two‐dimensional reversed‐phase liquid chromatography/electrospray ionization–tandem mass spectrometry (2D‐LC‐ESI/MS/MS) method was developed and validated to determine rifaximin in rat serum by direct injection. The 2D‐LC‐ESI/MS/MS system consisted of a restricted access media column for trapping proteins as the first dimension and a Waters C18 column as second dimension using 0.1% aqueous acetic acid:acetonitrile as mobile phase in a gradient elution mode. Rifampacin was used as an internal standard. The linear dynamic range was 0.5–10 ng/mL (r2 > 0.998). Acceptable precision and accuracy were obtained over the calibration range. The assay was successfully used in analysis of rat serum to support pharmacokinetic studies. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

16.
Dexmedetomidine (Dex) is a selective central α2‐agonist with anesthetic properties and has been used in clinical practice for sedation in the intensive care unit (ICU) after operations. In this study, an analytical assay for the determination of Dex in a small amount of plasma was developed for the application to pediatric ICU trials. The quantification of Dex was constructed using the original stable isotope Dex‐d3 for electrospray ionization‐tandem mass spectrometry (ESI‐MS/MS) in the selected reaction monitoring mode. A rapid ultra‐performance liquid chromatography technique was adopted using ESI‐MS/MS with a runtime of 3 min. Efficacious concentration levels (50 pg/mL to 5 ng/mL) could be evaluated using a very small amount of plasma (10 μL) from patients. The lower limit of the quantification was 5 pg/mL in the plasma (100 µL). For sample preparation, a solid‐phase extraction was used along with the OASIS‐HLB cartridge type. Recovery values ranged from 98.8 to 100.3% for the intra‐ [relative standard deviation (RSD), 0.9–1.3%] and inter‐ (RSD, 0.9–1.5%) day assays. A stable test had recovery values that ranged from 97.8 to 99.7% with an RSD of 1.0–1.9% for the process/wet extract, bench‐top, freeze–thaw and long‐term tests. This method was used to measure the Dex levels in plasma from pediatric ICU patients. In the clinical ICU trial, the small amount of blood (approximate plasma volume, 200 μL) remaining from blood gas analysis was reused and targeted for the clinical analysis of Dex in plasma. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

17.
A thalidomide analog, (4‐(1,3‐dioxo‐1,3‐dihydro‐2H‐isoindol‐2‐yl)‐N ′‐[(4‐ethoxyphenyl) methylidene] benzohydrazide), has been identified as a promising broad‐spectrum anti‐inflammatory agent in previous study. In this study, a sensitive and selective UPLC‐MS/MS assay was developed and validated for its determination in rat plasma samples. The chromatographic separation was performed on an Aquity BEH C18 column using mobile phase comprising of acetonitrile and 10 mm ammonium acetate in the ratio of 85: 15, at flow rate of 0.3 mL/min. The detection and quantification were performed in positive multiple reaction monitoring mode by parent to daughter ion transition of 414.06 ˃ 148.05 for analyte and 411.18 ˃ 191.07 for internal standard (risperidone), respectively using electrospray ionization source. The sample extraction process consisted of liquid–liquid extraction method using diethyl ether as the extracting solvent. The assay was validated by following FDA guidelines and all parameters were found to be within acceptable limits. The linearity was between 10.1 and 2500 ng/mL and the lower limit of quantification was 10.1 ng/mL. The reported results indicate that the assay could meet the requirement for analysis of this compound in amounts expected to the present in actual samples. Further, in vitro metabolic stability study was performed in rat liver microsomes by using the validated assay.  相似文献   

18.
CSUOH0901, a novel anticancer derivative of nimesulide, exhibits very promising anticancer activities in various cancer cell lines. In order to support further pharmacological and toxicological studies of this promising anticancer drug candidate, an LC‐MS/MS method was developed and validated in accordance with the US Food and Drug Administration guidelines. The drug molecules were extracted from plasma samples by protein precipitation and then analyzed with LC‐ESI‐MS/MS. An excellent analyte separation was achieved using a phenomenex C18 column with a mobile phase of 90% methanol and 5 m m of ammonium formate. The validated linear dynamic range was between 0.5 and 100 ng/mL and the achieved correlation coefficient (r2) was >0.9996. The results of inter‐ and intra‐day precision and accuracy were satisfactory, that is, <12% for accuracy and within ±5% for precision at a low and high quality control concentrations, respectively. In addition, the analyte and internal standard (JCC76) were found to be stable under the storage conditions at ?20°C for about 2 months. Hence, the acquired results proved that the LC‐ESI‐MS/MS method developed is precise, accurate and selective for the quantification of CSUOH0901 in plasma, and can be used for pharmacokinetic studies. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

19.
β‐Asarone (BAS), a phenylpropanoid from Acorus calamus Linn., has shown biological effects in the management of cognitive impairment conditions such as Alzheimer's disease. The present paper describes a selective and sensitive liquid chromatography–tandem mass spectrometric method (HPLC‐MS/MS) using electrospray ionization source (ESI) for quantification of BAS in rat plasma. Briefly, the plasma samples were pre‐treated using a simple solid‐phase extraction method. The separation of BAS and the internal standard, caffeine, was achieved on an Agilent Zorbax XDB C18 column (50 × 2.1 mm i.d., 5 µm) using 0.2 mL/min isocratic mobile phase flow. The detection was performed using an Applied Biosystems Hybrid Q‐Trap API 2000 mass spectrometer equipped with an ESI source operated in positive mode. Also, the developed bioanalytical method was validated as per the US FDA bioanalytical guidelines over the concentration range of 9.79–4892.50 ng/mL (r2 ≥ 0.9951) for BAS from rat plasma. The mean percentage recovery (n = 3) for the low, middle and high quality control samples was 86.92 ± 3.89, 85.30 ± 1.09 and 87.24 ± 4.03%, respectively. The applicability of the validated HPLC‐MS/MS method was demonstrated by successful measurement of BAS from plasma following oral administration of Acorus calamus rhizome extracts to three female albino Wistar rats. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

20.
A very accurate and selective LC‐MS/MS method was developed and validated for the quantification of 2′‐C‐modified nucleoside triphosphate in liver tissue samples. An efficient pretreatment procedure of liver tissue samples was developed, using a fully automated SPE procedure with 96‐well SPE plate (weak anion exchange sorbent, 30 mg). Nucleotide hydrophilic interaction chromatography has been performed on an aminopropyl column (100 mm×2.0 mm, 3 μm) using a gradient mixture of ACN and ACN/water (5:95 v/v) with 20 mM ammonium acetate at pH 9.45 as mobile phase at 300 μL/min flow rate. The 2′‐C‐modified nucleoside triphosphate was detected in the negative ESI mode in multiple reaction monitoring (MRM) mode. Calibration curve was linear over the 0.05–50 μM concentration range. Satisfying results, confirming the high reliability of the established LC‐MS/MS method, were obtained for intraday precision (CV = 2.5–9.1%) and accuracy (92.6–94.8%) and interday precision (CV = 9.6–11.5%) and accuracy (94.4–102.4%) as well as for recovery (82.0–112.6%) and selectivity. The method has been successfully applied for pharmacokinetic studies of 2′‐C‐methyl‐cytidine‐triphosphate in liver tissue samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号