首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The bidentate ligand diformylhydrazine (OHC-HN-NH-CHO), DFH, combines with iron(II) and iron(III) in alkaline media in the pH range 7.3-9.3 to form an intensely colored red-purple iron(III) complex with an absorption maximum at 470 nm. Beer's law is obeyed for iron concentrations from 0.25 to 13 microg mL(-1). The molar absorptivity was in the range 0.3258x10(4)-0.3351x10(4) L mol(-1) cm(-1) and Sandell's sensitivity was found to be 0.0168 microg cm(-2). The method has been applied to the determination of iron in industrial waste, ground water, and pharmaceutical samples.  相似文献   

2.
Cloud point extraction (CPE) was applied as a preconcentration step prior to graphite furnace atomic absorption spectrometry (GFAAS) determination of manganese(II) and iron(III) in water samples. After complexation with 1-phenyl-3-methyl-4-benzoyl-5-pyrazolone (PMBP), the analytes could be quantitatively extracted to the phase rich in the surfactant p-octylpolyethyleneglycolphenylether (Triton X-100) and be concentrated, then determined by GFAAS. The parameters affecting the extraction efficiency, such as solution pH, concentration of PMBP and Triton X-100, equilibration temperature and time, were investigated in detail. Under the optimum conditions, preconcentration of 10 ml of sample solution permitted the detection of 0.02 ng ml(-1) of Mn(II) and 0.08 ng ml(-1) of Fe(III) with enrichment factors of 31 and 25 for Mn(II) and Fe(III), respectively. The proposed method was applied to determination of trace manganese(II) and iron(III) in water samples with satisfactory results.  相似文献   

3.
The solution properties of nickel complex with 4-(2'-benzo-thiazolylazo) salicylic acid (BTAS) have been studied by zero-order absorption spectrophotometry in 40% (v/v) ethanol at 20 degrees C and an ionic strength of 0.1 mol dm(-3) (KNO(3)). The equilibria that exist in solution were established and the basic characteristics of complexes formed were determined. A new direct spectrophotometric method for the determination of trace amounts of the nickel is proposed based on the formation of the Ni (BTAS) complex at pH 7.0. The absorption maximum, molar absorbtivity, and Sandell's sensitivity of 1:1 (M:L) complex are 525 nm, 0.6 x 10(4) l mol(-1) cm(-1) and 2.824 x 10(-9) microg cm(-2), respectively. The use of first-derivative spectrophotometry eliminates the interference of iron and enables the simultaneous determination of nickel and iron using BTAS. Quantitative determination of Ni(II) and Fe(III) is possible in the range (0.59-7.08) and (2.1-8.4) microg ml(-1), respectively with a relative standard deviation of 0.5%. The proposed method has been successfully applied to the simultaneous spectrophotometric determination of nickel and iron in steel alloys and aluminum alloys.  相似文献   

4.
Parkash R  Bala R  Lal Singhal R 《Talanta》1979,26(7):575-576
Iron(III) has been determined by DCTA titration with p-aminosalicylic acid and sodium azide as indicator at pH 1.4-3.5. The titrations are rapid, simple, accurate and reversible and as little as 0.15 mg of iron(III) can be determined in the presence of up to 100 times as much of certain ions. Cadmium, zinc, lead, copper(II), aluminium, thorium, oxalate, phosphate, fluoride and sulphide interfere. The method is utilized for determination of iron(III) in presence of copper(II) or lead and in limestone, cement and haemetite.  相似文献   

5.
Mudasir  Yoshioka N  Inoue H 《Talanta》1997,44(7):1195-1202
A reversed phase ion-paired chromatographic method that can be used to determine trace amounts of iron (II,III), nickel (II) and copper (II) was developed and applied to the determination of iron (II) and iron (III) levels in natural water. The separation of these metal ions as their 4,7-diphenyl-1,10-phenanthroline (bathophenanthroline) chelates on an Inertsil ODS column was investigated by using acetonitrile-water (80/20, v/v) containing 0.06 M perchloric acid as mobile phase and diode array spectrophotometric detection at 250-650 nm. Chromatographic parameters such as composition of mobile phase and concentration of perchloric acid in mobile phase were optimized. The calibration graphs of iron (II), nickel (II) and copper (II) ions were linear (r > 0.991) in the concentration range 0-0.5, 0-2.0 and 0-4.0 mug ml(-1), respectively. The detection limit of iron (II), nickel (II) and copper (II) were 2.67, 5.42 and 18.2 ng ml(-1) with relative standard deviation (n = 5) of 3.11, 5.81 and 7.16% at a concentration level of 10 ng ml(-1) for iron (II) and nickel (II) and 25 ng ml(-1) for copper (II), respectively. The proposed method was applied to the determination of iron(II) and iron(III) in tap water and sea water samples without any interference from other common metal ions.  相似文献   

6.
The usefulness of coprecipitation with lanthanum phosphate for separation and preconcentration of some heavy metals has been investigated. Although lanthanum phosphate coprecipitates iron(III) and lead quantitatively at pH 2.3, iron(II) can barely be collected at this pH. This coprecipitation technique was applicable to the separation and preconcentration of iron(III) before inductively coupled plasma atomic-emission spectrometric (ICP-AES) determination; the recoveries of iron(III) and iron(II) from spiked water samples were 103-105% and 0.2-0.7%, respectively. The coprecipitation was also useful for separation of 20 microg lead from 100 mL of an aqueous solution that also contained 1-100 mg iron. Coprecipitation of iron was substantially suppressed by addition of ascorbic acid, which enabled recovery of 97-103% of lead added to the solution, bringing the recovery to within 1.6-5.0% of the relative standard deviations. Lanthanum phosphate can also coprecipitate cadmium and indium quantitatively, although chromium(III), cobalt, and nickel and large amounts of sodium, potassium, magnesium, and calcium are barely coprecipitated at pH approximately/= 3.  相似文献   

7.
The reagent bis(isovalerylacetone)ethylenediimine(H2IVA2en) has been examined for HPLC separation and UV determination of cobalt, copper, iron and platinum using off-line precolumn derivatization and extraction in chloroform. The complexes of cobalt(II), cobalt(III), iron(II), iron(III) and the reagent have been subsequently separated on a Microsorb C-18 column. The complexes were eluted isocratically using ternary mixtures of methanol/water/acetonitrile. Detection was achieved by UV monitoring. Detection limits for Co(II), Co(III), Fe(II) and Fe(III) were 2.5–5.0 ng/injection, based on 0.5–1.0 g/ml with 5 l/injection. The concentration of cobalt(II) and cobalt(III) in aqueous solution have been determined. The presence of oxovanadium(IV), platinum(II), and nickel(II) did not affect the determinations. The HPLC method developed has been applied to the determination of cobalt, copper, iron and platinum in pharmaceutical preparations at the 30 g/g to 15 mg/g level and the obtained results were compared to those of atomic absorption spectrometry.  相似文献   

8.
Summary The use of a strong orthophosphoric acid medium enables a direct titration of iron(II) to be made at room temperature (in an inert atmosphere) with potassium bromate using a potentiometric endpoint. Various organic substances like oxalate, tartrate, citrate, sucrose and glucose do not interfere. The method is, therefore, likely to be important for the determination of ferrous and ferric iron in pharmaceutical products.
Zusammenfassung Die direkte Titration von Eisen(II) mit Kaliumbromat kann in stark phosphorsaurer Lösung bei Zimmertemperatur (in inerter Atmosphäre) mit potentiometrischer Endpunktsbestimmung durchgeführt werden. Organische Verbindungen wie Oxalat, Tartrat, Citrat, Saccharose und Glucose stören nicht. Das Verfahren könnte daher bei der Eisen(II)- und Eisen(III)-bestimmung in Arzneimitteln Verwendung finden.
  相似文献   

9.
A simultaneous determination with UV detection/capillary electrophoresis for Fe(II) and Fe(III) was achieved using a sulfonated bathophenantholine and desfferioxamine B. When the electrophoretic buffer was 60 mmol l(-1) SDS, 10 mmol l(-1) acetic acid (pH 4.0) and 10 mmol l(-1) ascorbic acid and at -10 kV, the iron(II) and iron(III) could not only be completely separated, but also be sensitively determined.  相似文献   

10.
Pu X  Hu B  Jiang Z  Huang C 《The Analyst》2005,130(8):1175-1181
A method has been developed for the speciation of trace dissolved Fe(II) and Fe(III) in water by coupling gallic acid (GA) modified nanometer-sized alumina micro-column separation with inductively coupled plasma mass spectrometry (ICP-MS). The separation of Fe(II) and Fe(III) was achieved based on the obvious difference in reaction kinetics between Fe(II) and Fe(III) with GA. Fe(III) was selectively retained on the micro-column at pH 5.5-6.5, while Fe(II) could not be retained by the micro-column at the whole tested pH range of 1.0-6.5, and passed through the micro-column. The Fe(II) can be determined by ICP-MS directly without preconcentration/separation procedure, while Fe(III) retained on the micro-column was then eluted with 1.0 mL of 1 mol L(-1) HCl and determined by ICP-MS. The parameters affecting the separation of Fe(II) and Fe(III) were investigated systematically and the optimum separation conditions were established. Under the optimized conditions, the detection limits of 0.48 microg L(-1) and 0.24 microg L(-1) with relative standard deviation of 5.6% and 4.3%(C= 5 microg L(-1), n= 7) for Fe(II) and Fe(III) were found, respectively. No obvious effect on the speciation of Fe(II) and Fe(III) was found with the change of the ratio of Fe(II) and Fe(III) from 0 ratio 10 to 10 ratio 0. The proposed method was applied for the determination of trace Fe(II) and Fe(III) in environmental water and the recoveries for spiked samples were found to be in the range of 97-105%.  相似文献   

11.
A pneumatic flow injection-tandem spectrometer system, without a delivery pump was used for the speciation of iron. In this system, the suction force of a pneumatic nebulizer of a flame absorption spectrometer was used for solution delivery through the manifold. The Fe(III) and total Fe concentrations were determined using thiocyanate ion in a UV-Vis spectrometer and a FAAS, respectively. The Fe(II) was determined by the difference. The calibration curves were linear up to 18 microg mL(-1) and 25 microg mL(-1) with detection limits of 0.09 microg mL(-1) and 0.07 microg mL(-1) for Fe(III) and Fe(II), respectively. The mid-range precision and accuracy were <2.5% and +/-3% for the two species, respectively, at a sampling rate of 120 h(-1). This system was applied for the determination of Fe(III) and Fe(II) in industrial water, natural water and spiked samples.  相似文献   

12.
Watanabe H 《Talanta》1974,21(4):295-302
A simple and highly selective spectrophotometric method for the determination of cobalt based upon the rapid reaction with PAN in the presence of surfactants and minute amounts of ammonium persulphate at pH 5.0 is described. The cobalt(III) chelate is made water-soluble by a neutral surfactant. Triton X-100, combined with sodium dodecylbenzene sulphonate (DBS). Iron(III), bismuth, tin(IV) and aluminium are masked with oxalate or citrate. Iron(II) must be absent. The other metal-PAN chelates, except that of nickel, are readily decomposed by EDTA. Up to 150 microg of nickel does not interfere. When larger amounts up to 625 microg are present, the absorbance can be corrected by measurements at two wavelengths. In a strongly acid medium (below pH 0.5) the nickel and other metal chelates are completely and instantaneously decomposed, while the cobalt(III) chelate remains unchanged. When, in place of EDTA, several ml of 6M hydrochloric acid are added after the colour development, nickel in quantities up to 1250 microg can be tolerated. A several hundredfold excess of zinc and manganese does not interfere. At 620 nm Beer's law is obeyed over the cobalt concentration range 0.4-3.2 microg/ml. The precision (95% confidence) is +/- 1.0 microg for 100 microg of cobalt. The molar absorptivity is 1.90 x 10(4) l. mole(-1) .cm(-1).  相似文献   

13.
Khuhawar MY  Lanjwani SN 《Talanta》1998,46(4):485-490
The complexing reagent 2-thiophenaldehyde-4-phenyl-3-thiosemicarbazone (TAPT) was examined for high performance liquid chromatographic (HPLC) separations of cobalt(II), copper(II) and iron(II) or cobalt(II), nickel(II), iron(II), copper(II) and mercury(II) as metal chelates on a Microsorb C-18, 5-mum column (150x4.6 mm i.d.) (Rainin Instruments Woburn, MA, USA). The complexes were eluted isocratically with methanol:acetonitrile:water containing sodium acetate and tetrabutyl ammonium bromide (TBA). UV detection was at 254 nm. The solvent extraction procedure was developed for simultaneous determination of the metals, with detection limits within 0.5-2.5 mug ml(-1) in the final solution. The method was applied for the determination of copper, cobalt and iron in pharmaceutical preparation.  相似文献   

14.
The H-point standard addition method was applied to kinetic data for simultaneous determination of Fe(II) and Fe(III) or selective determination of Fe(II) in the presence of Fe(III). The method is based on the difference in the rate of complex formation between iron in two different oxidation states and methylthymol blue (MTB) at pH 3.5 in mixed cetyltrimethylammonium bromide (CTAB) and Triton X-100 micellar medium. Fe(II) can be determined in the range 0.25-2.5 microg ml(-1) with satisfactory accuracy and precision in the presence of excess Fe(III) and other metal ions that rapidly form complexes with MTB under working condition. The proposed method was successfully applied to the simultaneous determination of Fe(II) and Fe(III) or selective determination of Fe(II) in the presence of Fe(III) in spiked real environmental and synthetic samples with complex composition.  相似文献   

15.
First- and second-derivative spectrophoto-metric methods for the simultaneous determination of aluminium and iron in their mixtures are described. The methods are based on the colored complexes formed by aluminium and iron with hematoxylin in the presence of cetyltrimethylammonium bromide as a surfactant. The zero-crossing method has been utilized to measure the first- and second-derivative value of the derivative spectrum. Aluminium (0.05-1 microg ml(-1)) could be determined in the presence of iron (0.09-1.6 microg ml(-1)) and vice versa. The detection limits of aluminium and iron are 0.01 and 0.09 microg ml(-1), respectively in the first-derivative mode and 0.014 and 0.1 microg ml(-1) in the second-derivative mode. The proposed method has been applied to the simultaneous determination of aluminium and iron in glasses, phosphate rocks, cement and magnesite alloy.  相似文献   

16.
A rapid, simple, and selective method was developed for the determination of etodolac. The method depends on complexation of etodolac with copper (II) acetate and iron (III) chloride followed by extraction of complexes with dichloromethane and then measuring the extracted complexes spectrophotometrically at 684 and 385 nm in case of Cu (II) or Fe (III), respectively. Different factors affecting the reaction, such as pH, reagent concentration, and time, were studied. By use of Job's method of continuous variation, the molar ratio method, and elemental analysis, the stoichiometry of the reaction was found to be in the ratio of 1:2 and 1:3, metal:drug in the case of Cu (II) and Fe (III), respectively. The method obeys Beer's law in a concentration range of 2.00-9.00 and 0.50-2.00 mg/mL in case of Cu (II) and Fe (III), respectively. The stability of the complexes formed was also studied, and the reaction products were isolated for further investigation. The complexes have apparent molar absorptivities of about 32.14 +/- 0.97 and 168.32 +/- 1.12 for Cu (II) and Fe (III), respectively. The suggested procedures were successfully applied to the analysis of pure etodolac and its pharmaceutical formulations. The validity of the procedures was further ascertained by the method of standard additions, and the results were compared with other reported spectrophotometric methods and showed no significant difference in accuracy and precision.  相似文献   

17.
A flow injection-photometric method has been developed for the determination of iron(II+III). The method is based on the catalytic effect of iron(III) on the hydrogen peroxide oxidation of 3,3',5,5'-tetramethylbenzidine to form a blue compound (lambda(max)=650 nm). In this catalyzed reaction, 1,10-phenanthroline acted as an effective activator. Iron(II) is also determined, being oxidized by hydrogen peroxide. Calibration graphs for iron(II) and iron(III) obtained under the optimized conditions were identical with each other and linear in the range 0.2-200 ng ml(-1) with a detection limit of 0.05 ng ml(-1) iron. The reproducibility was satisfactory with a relative S.D. of 1.0% for ten determinations of 5 ng ml(-1) iron(III). The proposed method was successfully applied to the determination of iron in river and lake water samples and can be determined free iron species.  相似文献   

18.
A sequential injection analysis (SIA) system is proposed for the determination of iron (II). Fe(II) was determined by SIA based on the reaction between 1,10-phenanthroline and iron (II), yielding an orange–red colour complex with absorption maximum at 512 nm. The method involved aspiration of 187 μl sample/standard zone followed by a zone of a reagent solution containing 140 μl of 7.8 × 10−4 mol l−1 1,10-phenanthroline into a carrier stream to be stacked inside a holding coil and flow reversed through a reaction coil to a detector. The optimum condition was evaluated and the calibration curve is linear over a range of 0.25 to 5.0 mg l−1 of Fe(II) with detection limit of 18 μg l−1. A sample throughput of 40 h−1 was established. This technique is found to be simple, accurate, reproducible and sensitive. The proposed method was successfully applied for the determination of total iron as Fe(II) in pharmaceutical products (multi-vitamin tablets) and is especially useful for the determination of iron (II) in tablets with lower iron (II) contents. The results were found to be in good agreement with the results obtained by manual UV/Vis spectrophotometry and flame atomic absorption spectrometry (FAAS) and with claimed values by the manufacturers.  相似文献   

19.
A simple and sensitive spectrophotometric method is suggested for analysis of 3 antihistaminic drugs, acrivastine (I), mequitazine (II), and dimethindene maleate (III). The method is based on reaction of the drugs with 7,7,8,8-tetracyanoquinodimethane (TCNQ) in acetonitrile to form highly stable colored products that are measured at 750, 766, and 844 nm for I and II, and 480 and 618 nm for III. Beer's law is obeyed in the ranges of 5-60 microg/mL for 1, 5-50 microg/mL for II, and 10-70 microg/mL for III. The optimum assay conditions and their applicability to the determination of the cited drugs in pharmaceutical formulations are described. The method is statistically analyzed as compared with the European Pharmacopoeia (2001) method for the analysis of dimethindene maleate and reference methods for acrivastine and mequitazine drugs revealing good accuracy and precision.  相似文献   

20.
Zenki M  Tanishita A  Yokoyama T 《Talanta》2004,64(5):1273-1277
Ascorbic acid (AA) could be determined in large quantities of a co-existing oxidant. The incorporation of an on-line reagent regeneration step based on redox reaction eliminates the baseline drift in the procedure. This makes it possible to adopt a circulatory flow injection method (cyclic FIA) and to determine AA repetitively. The method is based on the reduction of iron(III) to iron(II) by the analyte, the reaction of the produced iron(II) with 1,10-phenanthroline (phen) in a weak acidic medium to form a colored complex, and the subsequent oxidation reaction of iron(II) to iron(III) by the co-existing peroxodisulfate. A solution (50 ml) of 3.0×10−4 mol l−1 ferric chloride, 9.0×10−4 mol l−1 phen and 5.0×10−2 mol l−1 ammonium peroxodisulfate in acetate buffer (0.2 mol l−1, pH 4.5) is continuously circulated at a constant flow rate of 1.0 ml min−1. Into this stream, an aliquot (20 μl) of the sample solution containing AA is quickly injected by means of a six-way valve. The complex formed is monitored spectrophotometrically (at 510 nm) in the flow system. The stream then returns to the reservoir after passing through a time-delay coil (50 m). The iron(II)–(phen)3 complex is oxidized to iron(III)–(phen)3 complex by peroxodisulfate which exists excessively in the circulating reagent solution. The proposed method allows as many as 300 repetitive determinations of 15 mg l−1 AA with only 50 ml reservoir solution. The contents of AA in commercial pharmaceutical products were analyzed to demonstrate the capability of the developed system.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号