1.
Reduction of through-pore size and skeleton size of a monolithic silica column was attempted to provide high separation efficiency in a short time. Monolithic silica columns were prepared to have various sizes of skeletons (approximately 1-2 microm) and through-pores (approximately 2-8 microm) in a fused-silica capillary (50-200 microm I.D.). The columns were evaluated in HPLC after derivatization to C18 phase. It was possible to prepare monolithic silica structures in capillaries of up to 200 microm I.D. from a mixture of tetramethoxysilane and methyltrimethoxysilane. As expected, a monolithic silica column with smaller domain size showed higher column efficiency and higher pressure drop. High external porosity (> 80%) and large through-pores resulted in high permeability (K = 8 x 10(-14) -1.3 x 10(-12) m2) that was 2-30 times higher than that of a column packed with 5-mirom silica particles. The monolithic silica columns prepared in capillaries produced a plate height of about 8-12 microm with an 80% aqueous acetonitrile mobile phase at a linear velocity of 1 mm/s. Separation impedance, E, was found to be as low as 100 under optimum conditions, a value about an order of magnitude lower than reported for conventional columns packed with 5-microm particles. Although a column with smaller domain size generally resulted in higher separation impedance and the lower total performance, the monolithic silica columns showed performance beyond the limit of conventional particle-packed columns under pressure-driven conditions.  相似文献   

2.
The analysis of complex real-world samples of vegetable origin requires rapid and accurate routine methods, enabling laboratories to increase sample throughput and productivity while reducing analysis costs. This study examines shortening enantioselective-GC (ES-GC) analysis time following the approaches used in fast GC. ES-GC separations are due to a weak enantiomer-CD host-guest interaction and the separation is thermodynamically driven and strongly influenced by temperature. As a consequence, fast temperature rates can interfere with enantiomeric discrimination; thus the use of short and/or narrow bore columns is a possible approach to speeding-up ES-GC analyses. The performance of ES-GC with a conventional inner diameter (I.D.) column (25 m length x 0.25 mm I.D., 0.15 microm and 0.25 microm d(f)) coated with 30% of 2,3-di-O-ethyl-6-O-tert-butyldimethylsilyl-beta-cyclodextrin in PS-086 is compared to those of conventional I.D. short column (5m length x 0.25 mm I.D., 0.15 microm d(f)) and of different length narrow bore columns (1, 2, 5 and 10 m long x 0.10 mm I.D., 0.10 microm d(f)) in analysing racemate standards of pesticides and in the flavour and fragrance field and real-world-samples. Short conventional I.D. columns gave shorter analysis time and comparable or lower resolutions with the racemate standards, depending mainly on analyte volatility. Narrow-bore columns were tested under different analysis conditions; they provided shorter analysis time and resolutions comparable to those of conventional I.D. ES columns. The narrow-bore columns offering the most effective compromise between separation efficiency and analysis time are the 5 and 2m columns; in combination with mass spectrometry as detector, applied to lavender and bergamot essential oil analyses, these reduced analysis time by a factor of at least three while separation of chiral markers remained unaltered.  相似文献   

3.
A sensitive, specific and reliable liquid chromatography/tandem mass spectrometry (LC/MS/MS) method has been developed for simultaneous determination of D-amino acids in the central nervous system (CNS) of Aplysia californica. In order to correct for any potential matrix effects on measured signals, deuterium-labeled L-Asp-d3 was used as an internal standard. Pre-column derivatization of the sample with 7-fluoro-4-nitrobenzoxadiazole (NBD-F) allowed both effective in-line pre-concentration and sensitive MS/MS detection of the analytes. An extraction column (50x0.25 mm, 5 microm C18 silica particles) was used to pre-concentrate/stack samples. Enantiomeric separation of amino acid enantiomers was achieved on a chiral column packed with teicoplanin aglycone bonded silica particles (170x0.25 mm, 5 microm) with an MS-friendly mobile phase. The characteristic precursor to product ion transitions, m/z 297-->279 (for NBD-Asp), m/z 269-->223 (For NBD-Ser), m/z 311-->293 (for NBD-Glu) and m/z 300-->282 (for NBD-L-Asp-d3) were monitored for the quantification. Samples from the CNS of A. californica and heart tissues were analyzed. D-Asp was detected at high levels in all the ganglia and nerve tissues, but not in the heart tissue. Further, neither D-Ser nor D-Glu was detected in Aplysia, a widely used neuronal model.  相似文献   

4.
Ultra performance LC (UPLC) was evaluated as an efficient screening approach to facilitate method development for drug candidates. Three stationary phases were screened: C-18, phenyl, and Shield RP 18 with column dimensions of 150 mm x 2.1 mm, 1.7 microm, which should theoretically generate 35,000 plates or 175% of the typical column plate count of a conventional 250 mm x 4.6 mm, 5 microm particle column. Thirteen different active pharmaceutical ingredients (APIs) were screened using this column set with a standardized mobile-phase gradient. The UPLC method selectivity results were compared to those obtained for these compounds via methods developed through laborious trial and error screening experiments using numerous conventional HPLC mobile and stationary phases. Peak capacity was compared for columns packed with 5 microm particles and columns packed with 1.7 microm particles. The impurities screened by UPLC were confirmed by LC/MS. The results demonstrate that simple, high efficiency UPLC gradients are a feasible and productive alternative to more conventional multiparametric chromatographic screening approaches for many compounds in the early stages of drug development.  相似文献   

5.
Oligonucleotides and double stranded DNA fragments were separated in 200 microm I.D. capillary columns packed with micropellicular, octadecylated, 2.1 microm poly(styrene-divinylbenzene) particles by ion-pair reversed-phase high-performance liquid chromatography (IP-RP-HPLC). Both the length and the diameter of the connecting capillaries (150 x 0.020 mm I.D.) as well as the detection volume (3 nl) had to be kept to a minimum in order to maintain the high efficiency of this chromatographic separation system with peak widths at half height in the range of a few seconds. Three different types of frits, namely sintered silica particles, sintered octadecylsilica particles, and monolithic poly(styrene-divinylbenzene) (PS-DVB) frits were evaluated with respect to their influence on chromatographic performance. Best performance for the separation of oligonucleotides and long DNA fragments was observed with the PS-DVB frits, whereas the short DNA fragments were optimally resolved in columns terminated by octadecylsilica frits. The maximum loading capacity of 60 x 0.20 mm I.D. columns ranged from 20 fmol (7.7 ng) for a 587 base pair DNA fragment to 500 fmol (2.4 ng) for a 16-mer oligonucleotide. Lower mass- and concentration detection limits in the low femtomol and low nanomol per liter range, respectively, make capillary IP-RP-HPLC with UV absorbance detection highly attractive for the separation and characterization of minute amounts of synthetic oligonucleotides, DNA restriction fragments, and short tandem repeat sequences amplified by polymerase chain reaction.  相似文献   

6.
Evaluation of frontal chromatograms   总被引:3,自引:0,他引:3  
A novel pressure-balanced injection valve was evaluated for use with ultrahigh pressure liquid chromatography (UHPLC) at pressures up to 120 MPa (1,200 bar). Fused-silica capillaries (30-33 cm x 100 microm I.D.) packed with nonporous 1.5 microm isohexylsilane-modified (C6) silica particles were employed to study maximum pressure, injection reproducibility, injection time, and sample amount consumed for an injection. The new valve was more reproducible, convenient, and required much less sample than previously used injection systems. The effect of column diameter on efficiency and sensitivity was studied. The 100 microm I.D. columns demonstrated approximately 40% lower efficiency but 10-fold higher sensitivity than the 29 microm I.D. columns. Columns packed with nonporous C6 particles produced higher efficiencies than columns packed with a 1.5 microm porous octadecylsilane-modified (C18) material.  相似文献   

7.
High efficiency separations (200 000 plates) were obtained on conventional LC equipment by coupling 8 x 25 cm x 2.1 (or 4.6) mm id x 5 microm d(p) ODS columns (total length 2 m) and operation at 60 degrees C using a dedicated LC oven. The peak capacity in this 1-D set-up was 900 for the separation of human serum tryptic peptides analyzed after depletion of six highly abundant proteins. The chromatographic performance of an elevated temperature-extended column length conventional LC is highlighted.  相似文献   

8.
In the paper we demonstrate a new approach for the preparation and application of continuous silica bed columns that involve encapsulation (entrapment) of functionalized silica microparticles, which can be used as packing material in micro high performance liquid chromatography (micro-HPLC) and capillary electrochromatography (CEC). Like traditional packed columns, these capillaries possess characterized silica particles that offer high phase ratio and narrow pore size distribution leading to high retention and separation efficiency, respectively. More importantly, immobilization of the microparticles stabilizes the separation bed and eliminates the need for retaining frits. The developed capillary columns were fabricated in exactly the same way as a packed capillary column (slurry packing) but with an additional entrapment step. This immobilization of the packed bed was achieved by in situ polymerization of styrene and divinylbenzene in presence of decanol as a porogen and azobisisobutyronitrile as thermal initiator. Silica particles with different particle sizes and pore sizes ranging from 60 to 4000 A were studied. In addition different modified silica was used, including C-18 reversed phase, anion exchange and chiral stationary phases. Efficient separation of polyphenolic compounds, peptides, proteins and even DNA mutation were achieved using the developed technique depending on the properties of the silica particles used (particles pore size). For example, using 3 microm ProntoSIL C-18 particles with 300 A pore size, separation efficiencies in the range of 120,000-200,000 plates/m were obtained for protein separation, in a 6 cm x 200 microm i.d. capillary column. Using encapsulated silica C-18 with 1000 A pore size, separation of DNA homo and hetero duplexes were achieved under denaturing HPLC conditions for mutation detection. In addition, nucleotides were separated using anion exchange material encapsulated with poly(styrene-divinylbenzene) (PS/DVB), which indicated that the chromatographic properties of the silica packing material were still active after polymerization. The prepared capillary columns were found to be stable and could easily be operated continuously up to a pressure of 350 bar without column damage and capillary can be cut to any desired length.  相似文献   

9.
Babú YN  Nemec M  Solich P  Wsól V 《Talanta》2008,75(2):494-502
Glucuronidation of the non-steroidal anti-inflammatory chiral drug flobufen and its major metabolite M17203 has been implicated as an important mechanism of flobufen elimination. To characterize flobufen metabolism by O-glucuronidation, new liquid chromatographic method (LC) coupled with ESI-MS was developed to detect the conjugates of flobufen and its metabolites formed in vitro in rat liver microsomes. Discovery DSC-18 LT cartridge columns were utilized for solid phase extraction (SPE) and Discovery C18 column (150 mm x 2.1 mm, 5 microm particle size) was used for LC separation. Chiral inversion of flobufen and its metabolites enantiomers was checked by special 1-allyl-(5R,8S,10R)-terguride column (150 mm x 4.6 mm). O-Glucuronidation of the S-enantiomer displayed a typical Michaelis-Menten kinetics, whereas the R-enantiomer exhibited a substrate inhibition type of kinetics. The study of glucuronidation of M17203 led to kinetics with sigmoidal characteristics.  相似文献   

10.
Continuous-bed columns containing sol-gel bonded 3 microm silica particles with mixed-mode octadecyl and propylsulfonic acid functional groups (ODS/SCX) were prepared by first packing the ODS/SCX particles into a fused-silica capillary, then filling the packed capillary with a siliceous sol-gel, curing the sol-gel, and finally drying the column with supercritical carbon dioxide. The performance of the sol-gel bonded ODS/SCX columns was evaluated for capillary electrochromatography using acetonitrile aqueous mobile phase containing phosphate buffer. The columns were mechanically strong and permeable. Both EOF velocity and current increased linearly with elevation of the applied electric field strength. The EOF velocity was high at low pH and nearly constant over a range of pH 2-9. Higher buffer concentration resulted in higher current and lower EOF velocity. The acetonitrile content had no significant effect on the EOF. Without thermosetting the column, no bubble formation was noticed with currents up to 2.5 microA. The minimum plate height of a 25/34 cm x 75 microm I.D. sol-gel bonded 3 microm ODS/SCX column was 5.7 microm (1.75 x 10(5) plates per meter) at an optimum EOF velocity of 0.92 mm s(-1). Mixtures of test aromatic compounds and aromatic hydrocarbon homologues gave symmetrical peaks when using a low pH mobile phase. The retention and elution order of aromatic compounds represented a typical reversed-phase separation mechanism similar to conventional ODS columns. The run-to-run and column-to-column retention factor reproducibility was better than 2.5% and 8.0% RSD, respectively.  相似文献   

11.
In this study, 1-D and 2-D liquid chromatographic systems, namely, conventional HPLC, UPLC, HPLC x HPLC and HPLC x UPLC systems were developed and evaluated for the separation of phenolic acids in wine and juices. In the LC x LC studies, the first dimension separation was based on RPLC and the second dimension was performed with ion-pair chromatography. Three different columns, namely two short columns packed with either 2.5 or 1.7 microm particles and a monolithic column, were tested for the fast second dimension separation. The best results were obtained when the monolithic column was applied for the second dimension separation. The peak capacities for comprehensive 2-D systems varied from 330 to 616.  相似文献   

12.
Monolithic silica capillary columns were successfully prepared in a fused silica capillary of 530 microm inner diameter and evaluated in HPLC after octadecylsilylation (ODS). Their efficiency and permeability were compared with those of columns pakked with 5-microm and 3-microm ODS-silica particles. The monolithic silica columns having different domain sizes (combined size of through-pore and skeleton) showed 2.5-4.0-times higher permeability (K= 5.2-8.4 x 10(-14) m2) than capillary columns packed with 3-mm particles, while giving similar column efficiency. The monolithic silica capillary columns gave a plate height of about 11-13 microm, or 11 200-13 400 theoretical plates/150 mm column length, in 80% methanol at a linear mobile phase velocity of 1.0 mm/s. The monolithic column having a smaller domain size showed higher column efficiency and higher pressure drop, although the monolithic column with a larger domain size showed better overall column performance, or smaller separation impedance (E value). The larger-diameter (530 microm id) monolithic silica capillary column afforded a good peak shape in gradient elution of proteins at a flow rate of up to 100 microL/min and an injection volume of up to 10 microL.  相似文献   

13.
Vancomycin-capped (3-(2-O-β-cyclodextrin)-2-hydroxypropoxy)-propylsilyl-appended silica particles (VCD-HPS), a new type of substituted β-cyclodextrin-bonded chiral stationary phase (CSP) for liquid chromatography (LC), have been synthesized by treatment of bromoacetate-substituted-(3-(2-O-β-cyclodextrin)-2-hydroxypropoxy)-propylsilyl-appended silica particles (BACD-HPS) with vancomycin in anhydrous methanol. The stationary phase is characterized by elemental analysis. This new CSP has a chiral selector with two recognition sites: vancomycin and β-cyclodextrin (β-CD), which can provide multiple interactions with the solutes. The chromatographic performance of VCD-HPS was studied with several disubstituted benzenes and some chiral drug compounds as solutes in reversed-phase LC. The results show that VCD-HPS has excellent selectivity for the separation of aromatic positional isomers and enantiomers of chiral compounds.  相似文献   

14.
In this work a new type of chiral monolith silica column was developed for the chiral separation by micro high-performance liquid chromatography (micro-HPLC). The chiral monolith column with a continuous skeleton and a large through-pore structure was prepared inside a capillary of 100 microm I.D. by a sol-gel process, and chemically modified with chiral selectors, such as L-phenylalaninamide, L-alaninamide and L-prolinamide, on the surface of the monolithic silica column. Based on the principle of ligand exchange, these chiral monolithic columns were successfully used for the separation of dansyl amino acid enantiomers, as well as hydroxy acid enantiomers by micro-HPLC. The chromatographic conditions, the enantioselectivity and the performance of columns are discussed.  相似文献   

15.
A hydride-based octadecyl stationary phase on both 4.0 and 1.8 microm silica particles is tested in both the capillary LC and the pressurized capillary electrochromatography (pCEC) modes. These two materials are compared to standard C18 stationary phase made by organosilanization and to the hydride material packed into a convention 4.6mm I.D. column. The performance of the capillary columns is evaluated in terms of analysis times for various mixtures as well as efficiency. Of particular interest are the differences between the LC mode where only laminar flow is present and pCEC operation where a flat electrodriven flow profile is superimposed on the parabolic pressurized flow. Differences in performance between columns packed with 4.0 and 1.8 microm particle silica are also evaluated.  相似文献   

16.
Porous sol-gel frits are fabricated in a capillary column by filling it with a solution of 3-(trimethoxysilyl)propyl methacrylate, hydrochloric acid, water, toluene (porogen), and a photoinitiator (Irgacure 1800) and exposing it to UV light at 365 nm for 5 min. The separation column (30 cm x 75 microm I.D.) contains between the inlet and outlet frits a 15-cm packed segment filled with 5-microm silica particles modified with the chiral compound (S)-N-3,5-dinitrobenzoyl-1-naphthylglycine. A detection window (1 mm long) is placed immediately after the outlet frit. To demonstrate the performance of this chiral separation column, mixtures of 16 different amino acids (three of which are not naturally occurring) derivatized with the fluorogenic reagent 4-fluoro-7-nitro-2,1,3-benzoxadiazole were separated by capillary chromatography. The enantiomeric separation of the column results in a resolution ranging from 1.21 to 8.29, and a plate height ranging from 8.7 to 39 microm.  相似文献   

17.
Fritless particle-loaded monoliths for chiral capillary electrochromatographic (CEC) separation were prepared. Silica particles containing a chiral selector are suspended in a monomer solution, which is drawn into the capillary followed by in situ polymerization. Thereby the silica-based particles containing the chiral selector are embedded in a nonchiral continuous bed. This kind of chiral stationary phase is inexpensive, easy, and reproducible to prepare and circumvents the preparation of frits. As a model, teicoplanin aglycone as chiral selector bonded to 3 microm silica particles was used. The applicability of this approach is demonstrated by means of the chiral separation of aliphatic and aromatic amino acids and dipeptides. As a further application, the chiral selector ristocetin A bonded to 3 microm silica particles was used for the enantiomeric separation of chiral alpha-hydroxy acids. Since alpha-hydroxy acids migrate toward the anode, a cationic charge-providing agent was copolymerized with the matrix. This served to reverse the direction of the electroosmatic flow (EOF).  相似文献   

18.
An enantioselective silica rod type chiral stationary phase (CSP) is presented as a novel combination of the well-known enantiomer separation properties of immobilized tert-butyl-carbamoylquinine chiral anion-exchanger selector with the unique properties of monolithic silica material. The chromatographic behavior of the tert-butyl-carbamoylquinine silica rod was studied and compared with a similar prepared particulate material. Good selectivities were achieved for a spectrum of chiral test components like N-derivatized amino acids (DNB- Ac-, DNZ-, Bz-, Z-amino acids) and for Suprofen. The influence of mobile phase parameters, as well as the effect of serially coupling up to six 10 cm monolithic silica columns was studied and put in context to conventional columns of particulate 5 microm type CSP. Using that 60 cm long monolithic column it was possible to improve the enantiomer separation of Suprofen and achieve a baseline separation in less than 10 min of total separation time.  相似文献   

19.
Miniaturization embracing instrumentation, column particle size, and column dimensions is one of the major current trends in separation techniques. This leads to shortening of analysis time and great savings in solvent consumption. Ultra performance liquid chromatography (UPLC) is one of the new developments in liquid chromatography. An ultra-high pressure system allows using of small particle-packed columns with small diameter, which has a positive effect on both system efficiency and analysis time. An analytical method for determination of the active substance diclofenac, the degradation product 1-(2,6-dichlorphenyl)-2-indolinone, and the preservatives methylparaben and propylparaben was used for testing and comparing LC systems. Various octadecylsilica-based analytical columns were examined. Acquity UPLC BEH C18 (2.1 x 50 mm, 1.7 microm) and (2.1 x 100 mm, 1.7 microm) were tested for UPLC. The following analytical columns were used in a test for HPLC: Purospher RP 18e (125 x 4.0 mm, 5 microm), Zorbax Eclipse XDB C18 (75 x 4.6 mm, 3.5 microm), Zorbax Eclipse SB C18 (50 x 4.6 mm, 1.8 microm), as was a monolithic column (Chromolith Performance RP-18e (100 x 4.6 mm). Results of a System Suitability Test (SST) were calculated and compared for each chromatographic peak. System efficiency and analysis duration were compared with regard to solvent consumption and system maintenance  相似文献   

20.
High plate numbers were obtained in conventional LC by coupling columns and by using temperature to reduce the viscosity of the mobile phase. At 80 degrees C up to eight columns of 25 cm x 4.6 mm I.D. packed with 5 microm ODS particles could be coupled generating 180,000 effective plates while the pressure drop was only 350bar. For routine work, a set of four columns is preferred. The analysis times on one column operated at 30 degrees C and 1 mL/min flow rate and on four columns at 80 degrees C and 2 mL/min flow rate are the same in isoeluotropic conditions while the resolution is doubled. Multicolumn systems were successfully applied in isocratic and gradient mode for the analysis of pharmaceutical and environmental samples.  相似文献   