首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This paper describes a sensitive, specific and rapid high‐performance liquid chromatography (HPLC) method for the determination of curcumin in rat plasma. After a simple step of protein precipitation in 96‐well format using acetonitrile containing the internal standard (IS), emodin, plasma samples were analyzed by reverse‐phase HPLC. Curcumin and the IS emodin were separated on a Diamonsil C18 analytical column (4.6 × 100 mm, 5 µm) using acetonitrile–5% acetic acid (75:25, v/v) as mobile phase at a flow rate of 1.0 mL/min. The method was sensitive with a lower limit of quantitation of 1 ng/mL, with good linearity (r2 ≥ 0.999) over the linear range 1–500 ng/mL. All the validation data, such as accuracy and precision, were within the required limits. A run time of 3.0 min for each sample made high‐throughput bioanalysis possible. The assay method was successfully applied to the study of the pharmacokinetics of curcumin liposome in rats. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

2.
A sensitive, specific and efficient high‐performance liquid chromatography/tandem mass spectrometry assay for the simultaneous determination of vinorelbine and its metabolite 4‐O‐deacetylvinorelbine in human and mouse plasma is presented. Heated electrospray ionization was applied followed by tandem mass spectrometry. A 50 µL plasma aliquot was protein precipitated with acetonitrile–methanol (1:1, v/v) containing the internal standard vinorelbine‐d3 and 20 µL volumes were injected onto the HPLC system. Separation was achieved on a 50 × 2.1 mm i.d. Xbridge C18 column using isocratic elution with 1 mm ammonium acetate–ammonia buffer pH 10.5–acetonitrile–methanol (28:12:60, v/v/v) at a flow rate of 0.4 mL/min. The HPLC run time was 5 min. The assay quantifies both vinorelbine and 4‐O‐deacetylvinorelbine from 0.1 to 100 ng/mL using sample volumes of only 50 µL. Mouse plasma samples can be quantified using calibration curves prepared in human plasma. Validation results demonstrate that vinorelbine and 4‐O‐deacetylvinorelbine can be accurately and precisely quantified in human and mouse plasma with the presented method. The assay is now in use to support (pre‐)clinical pharmacologic studies with vinorelbine in humans and mice. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

3.
A rapid and sensitive LC‐electrospray ionization‐MS method was developed for determining vinorelbine in rat plasma. A 100 µL plasma sample was treated using a protein precipitation procedure and was chromatographed within 4 min using an Inertsil ODS‐3 C18 (2.1 × 50 mm, 5 µm) column. The selected ion monitoring ions [M + H]+ were m/z 779 and m/z 811 for vinorelbine and vinblastine (internal standard), respectively. The method validation showed that the calibration curve for vinorelbine was linear over a concentration range of 1–1000 ng/mL with lower limit of quantification at 1 ng/mL. The method has been successfully applied to pharmacokinetics in rat plasma. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

4.
A rapid high‐performance liquid chromatography–tandem mass spectrometry method has been developed and validated for simultaneous measurement of venlafaxine and O‐desmethylvenlafaxine in human plasma using fluoxetine as an internal standard. In the liquid–liquid extraction method, compounds and internal standard were extracted from plasma using methyl tertiary butyl ether as an extraction solvent. The HPLC separation of the analytes was performed on a Zorbax SB‐C18, 50 × 4.6 mm, 5 µm column, using a isocratic elution program using a mobile phase consisting of HPLC‐grade methanol: 5 mm ammonium acetate (80:20 v/v) at a flow‐rate of 1.0 mL/min with a total runtime of 3.0 min. The proposed method has been validated with a linear range of 4–400 ng/mL for venlafaxine and 5–500 ng/mL for O‐desmethyl venlafaxine. The method was applied for a bio‐equivalence study of 75 mg tablets formulation in 32 Indian male healthy subjects under fasting conditions. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

5.
A simple, rapid, and sensitive HPLC method based on 9H‐fluoren‐9‐ylmethyl chloroformate derivatization for the quantification of sertraline in rat plasma has been developed, requiring a plasma sample of only 0.1 mL, which was deproteinized and derivatized for 5 min in two single steps. The obtained derivative was stable at room temperature and was determined by HPLC using a fluorescence detector. The analytical column was a C(18) column and the mobile phase was acetonitrile and water (80:20, v/v). Calibration curves were linear in the range of 10–500 ng/mL. The limit of detection was approximately 3 ng/mL, and the lower limit of quantification was established at 10 ng/mL. The bias of the method was lower than 10%, and the within day as well as between day, relative standard deviations were lower than 12%. This analytical method was successfully applied to characterize sertraline pharmacokinetics in rats following intravenous (t1/2 = 213 ± 48 min, Cl = 43.1 ± 8.7 mL/min, Vd = 11560 ± 1861 mL) and oral (Cmax = 156 ± 76 ng/mL, tmax = 63.8 ± 16.3 min) administration of 2 and 5 mg, respectively.  相似文献   

6.
A simple and cost‐effective HPLC method was established for quantification of 5‐hydroxyeicosatetraenoic acid (5‐HETE) in human lung cancer tissues. 5‐HETE from 27 patients' lung cancer tissues were extracted by solid‐phase extraction and analyzed on a Waters Symmetry C18 column (4.6 × 250 mm, 5 µm) with a mobile phase consisting of methanol, 10 mm ammonium acetate, and 1 m acetic acid (70:30:0.1, v:v:v) at a flow rate of 1.0 mL/min. The UV detection wavelength was set at 240 nm. The calibration curve was linear within the concentration range from 10 to 1000 ng/mL (r2 > 0.999, n = 7), the limit of detection was 1.0 ng/mL and the limit of quantitation was 10.0 ng/mL for a 100 µL injection. The relative error (%) for intra‐day accuracy was from 93.14 to 112.50% and the RSD (%) for intra‐day precision was from 0.21 to 2.60% over the concentration range 10–1000 ng/mL. By applying this method, amounts of 5‐HETE were quantitated in human lung cancer tissues from 27 human subjects. The established HPLC method was validated to be a simple, reliable and cost‐effective procedure that can be applied to conduct translational characterization of 5‐HETE in human lung cancer tissues. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

7.
A high‐performance liquid chromatography (HPLC) method for assay of d ‐Lys6–GnRH contained in a microemulsion‐type formulation is described. The peptide is extracted from the microemulsion matrix and quantified using a two‐step gradient method. Separation from microemulsion compounds and potential peptide oxidation products was achieved on a Jupiter C18 column at 40°C, using a gradient of 10–35% CH3CN for peptide elution. The correlation of peak intensity measured at 220 nm and peptide concentration was linear over the range 2.5–60 µg/mL with a correlation coefficient of 0.9997 and a y‐intercept not significantly different from zero (p > 0.05). Intraday and interday variability of the assay was less than 5% for multiple injections of samples containing 7.5, 30 and 60 µg/mL. The lower limit of quantitation was calculated to be 0.38 µg/mL, and the lower limit of detection was 0.13 µg/mL. The assay was applied to samples that were stressed under physiological conditions (37°C, pH 7.4) over 4 days. Three degradation peaks were well resolved from the parent peptide, demonstrating the selectivity of the assay. Off‐line MALDI TOF mass spectrometry was applied to identify these degradation species as oxidation products of the peptide. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

8.
A simple and rapid reversed‐phase HPLC method for determination of rifaximin in rat serum and urine was developed. Separation of rifaximin from biological matrix was achieved by direct injection of rat serum and urine onto a restricted‐access medium, Supelco LC‐Hisep, a shielded hydrophobic stationary phase, using acetonitrile:water:acetic acid (18:82:0.1 v/v/v) as a mobile phase. The linear range was 0.10–20 µg/mL (r2 > 0.999, n = 6), intraday and interday variation was <6.10%. The limits of detection and quantification were 0.03 (signal‐to‐noise ratio >3) and 0.10 µg/mL (signal‐to‐noise ratio >10), respectively. The method was successfully applied to pharmacokinetic studies of rifaximin after an oral administration to rats. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

9.
A direct large volume injection high‐performance liquid chromatography (HPLC) method with homemade restricted‐access media (RAM) pre‐column and combined with a column‐switching valve was established and developed for determination rifampicin (RIP) in rat plasma. The rat plasma samples (100 μL) were injected directly onto pre‐column, where RIP was retained and pre‐concentrated, while proteins were washed to waste using a methanol–water (5:95) as the mobile phase at a flow rate of 1 mL/min. Then, by rotation of the switching valve at 5 min, the RIP were eluted from the pre‐column and transferred to an Luna C18 analytical column by the chromatographic mobile phase consisting of methanol–acetonitrile–10 mm ammonium format (60:5:35) at a flow rate of 1 mL/min. The total analytical run time was 15 min with UV detection wavelength at 254 nm. Carbamazepine was used as the internal standard. Excellent linear correlation (r = 0.9993) was obtained in the range of 0.25–8 µg/mL for rat plasma. The intra‐day and inter‐day precisions of RIP were all <5.0%. The recoveries were in the range of from 99.98–113.66% for plasma. This on‐line RAM‐HPLC method was successfully applied to the pharmacokinetic study of RIP in rat plasma. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

10.
Opicapone is a novel potent, reversible and purely peripheral third generation catechol‐O‐methyltransferase inhibitor, currently under clinical trials as an adjunct to levodopa therapy for Parkinson's disease. To support additional nonclinical pharmacokinetic studies, a novel high‐performance liquid chromatographic method coupled to a diode array detector (HPLC‐DAD) to quantify opicapone and its active metabolite (BIA 9–1079) in rat plasma and tissues (liver and kidney) is herein reported. The analytes were extracted from rat samples through a deproteinization followed by liquid‐liquid extraction. Chromatographic separation was achieved in less than 10 min on a reversed‐phase C18 column, applying a gradient elution program with 0.05 M monosodium phosphate solution (pH 2.45 ± 0.05) and acetonitrile. Calibration curves were linear (r2 ≥ 0.994) within the ranges of 0.04‐6.0 µg/mL for both analytes in plasma, 0.04‐4.0 µg/mL for opicapone in liver and kidney homogenates, and 0.07‐4.0 µg/mL and 0.06‐4.0 µg/mL for BIA 9–1079 in liver and kidney homogenates, respectively. The overall intra‐ and inter‐day accuracy ranged from ?12.68% to 7.70% and the imprecision values did not exceed 11.95%. This new HPLC‐DAD assay was also successfully applied to quantify opicapone and BIA 9–1079 in a preliminary pharmacokinetic study. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

11.
The objective of this study was to qualitatively and quantitatively evaluate bovine lactoferrin (bLf) and its stability using a rapid RP‐HPLC method. bLf could be rapidly detected within 20 min and quantitated at levels down to 5 µg/mL, and the equation of linearity was y = 86.10x + 178.31 with the correlation coefficient (r2) 0.9997. Quantitative data obtained in the present study proved the improved RP‐HPLC method to be a sensitive and accurate analytical tool for bLf determination. The proteolytic cleavage of bLf in simulated human gastrointestinal fluids was further analyzed by RP‐HPLC, and found to follow pseudo‐first‐order kinetics. The typical equation obtained by pepsin was log10 [At]/[A0] = ?0.03x (r2 = 0.85), and log10 [At]/[A0] = ?0.01x (r2 = 0.81) for trypsin and chymotrypsin combination. Pepsinolysis of bLf in simulated gastric fluid was relatively fast with the half‐life t1/2 23.1 min. The digestion of bLf in simulated intestinal fluid was slower with about a 3‐fold increase in half‐life (69.3 min). After the complete proteolysis of bLf, small cleaved peptide fragments were fully separated and identified by RP‐HPLC. The proteolytic study indicated that this validated RP‐HPLC was able to evaluate bLf stability though monitoring the derivatization products. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

12.
A simple HPLC‐UV method was developed and validated for the quantification of pterostilbene (3,5‐dimethoxy‐4'‐hydroxy‐trans‐stilbene), a pharmacologically active phytoalexin in rat plasma. The assay was carried out by measuring the UV absorbance at 320 nm. Pterostilbene and the internal standard, 3,5,4'‐trimethoxy‐trans‐stilbene eluted at 5.7 and 9.2 min, respectively. The calibration curve (20–2000 ng/mL) was linear (R2 > 0.997). The lower limits of detection and of quantification were 6.7 and 20 ng/mL, respectively. The intra‐ and inter‐day precisions in terms of RSD were all lower than 6%. The analytical recovery ranged from 95.5 ± 3.7 to 103.2 ± 0.7% while the absolute recovery ranged from 101.9 ± 1.1 to 104.9 ± 4.4%. This simple HPLC method was subsequently applied in a pharmacokinetic study carried out in Sprague–Dawley rats. The terminal elimination half‐life and clearance of pterostilbene were 96.6 ± 23.7 min and 37.0 ± 2.5 mL/min/kg, respectively, while its absolute oral bioavailability was 12.5 ± 4.7%. Pterostilbene appeared to have better pharmacokinetic characteristics than its natural occurring analog, resveratrol. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

13.
A simple, rapid, selective and sensitive HPLC‐UV method has been developed and validated for the determination of ponicidin in rat plasma. The analyte was extracted from rat plasma by liquid–liquid extraction with ethyl acetate as the extraction solvent. The LC separation was performed on a Zorbax Eclipse XDB C18 analytical column (150 × 4.6 mm i.d., 5 µm) with an isocratic mobile phase consisting of methanol–water–phosphoric acid (45:55:0.01, v/v/v) at a flow rate of 1.0 mL/min. There was a good linearity over the range of 0.1–25 µg/mL (r = 0.9995) with a weighted (1/C2) least square method. The lower limit of quantification was proved to be 0.1 µg/mL. The accuracy was within ±10.0% in terms of relative error and the intra‐ and inter‐day precisions were less than 9.1% in terms of relative standard deviation. After validation, the method was successfully applied to characterize the pharmacokinetics of ponicidin in rats. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

14.
A rapid high‐performance liquid chromatographic method was developed and validated for determination of tetrahydropalmatine (THP), an active component of Rhizoma Corydalis, in rat plasma. The samples were prepared using protein precipitation and separated on an Agilent XDB‐C18 column (150 × 4.6 mm, 5 µm) with the mobile phase consisting of methanol–0.1% phosphate acid solution, adjusted with triethylamine to pH 5.5 (65:35). Good linearity was found within 0.10–10.00 µg/mL of THP in rat plasma sample. The intra‐ and inter‐day precision values were less than 10%. The developed method was successfully applied to assess the pharmacokinetics of THP in spontaneously hypertensive rats (SHR) and normotensive rats. After oral administration of a single dose of THP (60 mg/kg), the maximum plasma concentrations were 6.15 ± 2.1 and 7.54 ± 2.9 µg/mL for normotensive rats and SHR, respectively. The mean values of AUC0–∞ of THP in SHR were 81.44 ± 45.0 µg h/mL, significantly higher (p < 0.05) than in normotensive rats (44.06 ± 19.6 µg h/mL). The t1/2 and MRT in SHR were much longer than that in healthy Sprague–Dawley rats, indicating slow elimination of THP in SHR. The results indicated that there are some differences in pharmacokinetics of THP in SHR and Sprague–Dawley rats and it is very important to investigate the pharmacokinetic properties of drugs in pathological conditions. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

15.
A specific and sensitive HPLC‐MS/MS method was developed and validated for the simultaneously quantification of isoliquiritigenin (ISL) and neoisoliquiritin (NIS) in rat plasma by oral administration. Analytes were analyzed on an Agilent 6460 LC‐MS/MS system (Agilent, USA) using an Agilent Zorbax SB‐C18 column (4.6 × 150 mm, 5 μm). Gradient elution was applied for the analyte separation using a mobile phase composed of 0.1% formic acid aqueous solution and methanol at a flow rate of 1.0 mL/min with a total running time of 12 min. The calibration curves for ISL and NIS showed good linearity in the concentrations ranging from 0.001 to 4.000 μg/mL with correlation coefficients >0.998. The precision, accuracy, recovery and stability were deemed acceptable. The method was applied to the pharmacokinetics study of ISL and NIS in rats by single and combination administration. The result showed that Cmax and AUC0→t of ISL were markedly increased from 0.53 to 1.20 μg/mL, and from 69.63 to 200.74 min μg/mL by combination administration. The mean t1/2 value was also prolonged from 64.55 to 203.74 min in the combination group. These results indicated that NIS may have been metabolized to ISL which increased the absorption and extended the elimination of ISL. However, little difference was found for NIS pharmacokinetics parameters between single NIS and the combination group, which suggested that there was no significant biotransformation of ISL to NIS. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

16.
Verproside, isovanilloylcatalpol, catalposide and 6‐O‐veratroyl catalpol are bioactive iridoid glucosides isolated from in a number of folk medicinal plants. A rapid, sensitive and selective liquid chromatography/mass spectrometric (LC/MS) method for the simultaneous determination of verproside, isovanilloylcatalpol, catalposide and 6‐O‐veratroyl catalpol in rat plasma was developed. The analytes were extracted from 50 µL of rat plasma with ethyl acetate using 7‐carboxymethyloxy‐3',4',5‐trimethoxyflavone as internal standard and analyzed on an X‐Bridge C18 column within 6.5 min with 40% methanol in 10 mm ammonium formate (pH 3.0). The analytes were quantified using an electrospray ionization mass spectrometry in the selected ion monitoring mode. The standard curves were linear over the concentration ranges of 10–2000 ng/mL for verproside, isovanilloylcatalpol and catalposide and 20–2000 ng/mL for 6‐O‐veratroyl catalpol. The coefficients of variation and relative errors of verproside, isovanilloylcatalpol, catalposide and 6‐O‐veratroyl catalpol for intra‐ and inter‐assay at four quality control levels were 2.5–8.0 and–4.0–6.6%, respectively. This method was successfully applied to the pharmacokinetic study of verproside and its possible metabolite isovanilloylcatalpol after intravenous administration of verproside, a candidate anti‐asthma drug, in male Sprague–Dawley rats. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

17.
A sensitive and specific ultra‐performance liquid chromatography–tandem mass spectrometry (UPLC‐MS‐MS) method for quantification of a newly developed anticancer agent NPD‐103 has been established. An aliquot of human plasma sample (200 µL) was spiked with 13C‐labeled paclitaxel (internal standard) and extracted with 1.3 mL of tert‐butyl methyl ether. NPD‐103 was quantitated on a C18 column with methanol–0.1% formic acid (75:25, v/v) as mobile phase using UPLC‐MS‐MS operating in positive electrospray ionization mode with a total run time of 3.0 min. For NPD‐103 at the concentrations of 1.0, 5.0 and 10.0 µg/mL in human plasma, the absolute extraction recoveries were 95.58, 102.43 and 97.77%, respectively. The linear quantification range of the method was 0.1–20.0 µg/mL in human plasma with linear correlation coefficients greater than 0.999. The intra‐ and inter‐day accuracy for NPD‐103 at 1.0, 5.0 and 10.0 µg/mL levels in human plasma fell into the ranges of 95.29–100.00% and 91.04–94.21%, and the intra‐ and inter‐day precisions were in the ranges of 8.96–11.79% and 7.25–10.63%, respectively. This assay is applied to determination of half‐life of NPD‐103 in human plasma. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

18.
A high‐performance liquid chromatographic method was developed for the analysis of 3'‐hydroxypterostilbene. This method involves the use of a Luna® C18 column with ultraviolet detection at 325 nm. The mobile phase consisted of acetonitrile, water and formic acid (50:50:0.01, v/v/v) with a flow rate of 0.8 mL/min. The calibration curves were linear over the range 0.5–100.0 µg/mL. The mean extraction efficiency was between 97.40 and 111.16%. The precision of the assay was 0.196–14.39% (RSD%), and within 15% at the limit of quantitation (0.5 µg/mL). The bias of the assay was <16% and within 15% at the limit of quantitation. This assay was successfully applied to pre‐clinical pharmacokinetic samples from rat urine and serum. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

19.
A simple and rapid RP‐HPLC‐DAD method was developed and validated for simultaneous determination of the dopamine antagonists haloperidol, its diazepane analog, and the dopamine agonist bromocriptine in rat plasma, to perform pharmacokinetic drug‐interaction studies. Samples were prepared for analysis by acetonitrile (22.0 μg/mL) plasma protein precipitation with droperidol as an internal standard, followed by a double‐step liquid‐liquid extraction with hexane : chloroform (70:30) prior to C‐18 separation. Isocratic elution was achieved using a 0.1% (v/v) trifluoroacetic acid in deionized water, methanol and acetonitrile (45/27.5/27.5, v/v/v). Triple‐wavelength diode‐array detection at the λmax of 245 nm for haloperidol, 254 nm for the diazepane analog and droperidol, and 240 nm for bromocriptine was carried out. The LLOQ of DAL, HAL, and BCT were 45.0, 56.1, and 150 ng/mL, respectively. In rats, the estimated pharmacokinetic parameters (i.e., t1/2, CL, and Vss) of HAL when administered with DAL and BCT were t1/2 = 16.4 min, Vss = 0.541 L/kg for HAL, t1/2 = 28.0 min, Vss = 2.00 L/kg for DAL, and t1/2 = 24.0 min, Vss = 0.106 L/kg for BCT. The PK parameters for HAL differed significantly from those previously reported, which may be an indication of a drug‐drug interaction. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

20.
A rapid and simple reverse‐phase high‐performance liquid chromatography (RP‐HPLC) was developed and validated for the quantification of kirenol in rat plasma after oral administration. Kirenol and darutoside (internal standard, IS) were extracted from rat plasma using Cleanert™ C18 solid‐phase extraction (SPE) cartridge. Analysis of the extraction was performed on a Thermo ODS‐2 Hypersil C18 reversed‐phase column with a gradient eluent composed of acetonitrile and 0.1% phosphoric acid. The flow rate was 1.0 mL/min and the detection wavelength was set at 215 nm. The calibration curve was linear over the range of 9.756–133.333 µg/mL (r2 = 0.9991) in rat plasma. The lower limits of detection and quantification were 2.857 and 9.756 µg/mL, respectively. The intra‐ and inter‐day precisions (relative standard deviation, RSD) were between 2.24 and 4.46%, with accuracies ranging from 91.80 to 102.74%. The extraction recovery ranged from 98.16 to 107.62% with RSD less than 4.81%. Stability studies showed that kirenol was stable in preparation and analytical process. The present method was successfully applied to the pharmacokinetic study of kirenol in male Sprague–Dawley rats after oral administration at a dose of 50 mg/kg. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号