1.
Four stereoisomeric components were produced during the synthesis of the antidepressant drug (1S, 4S)‐sertraline hydrochloride due to the two chiral carbon centers in its chemical structure, including (1S, 4S), (1R, 4R), (1S, 4R), and (1R, 4S)‐isomer. Stereoselective separation of the target isomer (1S, 4S)‐sertraline from the medicinal reaction mixtures by countercurrent chromatography using hydroxypropyl‐β‐cyclodextrin as the stereoselective selector was investigated. A biphasic solvent system composed of n‐hexane/0.20 mol/L phosphate buffer solution with pH 7.6 containing 0.10 mol/L of hydroxypropyl‐β‐cyclodextrin (1:1, v/v) was selected for separation of cis‐sertraline and trans‐sertraline using reverse phase elution mode and (1S, 4S)‐sertraline was separated with (1R, 4R)‐sertraline using recycling elution mode. A fabricated in‐house analytical countercurrent chromatographic apparatus was used for optimization of the separation conditions. Stationary phase retention and peak resolution were investigated for separation of cis‐sertraline and trans‐sertraline by the analytical apparatus.  相似文献   

2.
Recycling countercurrent chromatography was successfully applied to the resolution of 2‐(4‐bromomethylphenyl)propionic acid, a key synthetic intermediate for synthesis of nonsteroidal anti‐inflammatory drug loxoprofen, using hydroxypropyl‐β‐cyclodextrin as chiral selector. The two‐phase solvent system composed of n‐hexane/n‐butyl acetate/0.1 mol/L citrate buffer solution with pH 2.4 (8:2:10, v/v/v) was selected. Influence factors for the enantioseparation were optimized, including type of substituted β‐cyclodextrin, concentration of hydroxypropyl‐β‐cyclodextrin, separation temperature, and pH of aqueous phase. Under optimized separation conditions, 50 mg of 2‐(4‐bromomethylphenyl)propionic acid was enantioseparated using preparative recycling countercurrent chromatography. Technical details for recycling elution mode were discussed. The purities of both the S and R enantiomers were over 99.0% as determined by high‐performance liquid chromatography. The enantiomeric excess of the S and R enantiomers reached 98.0%. The recovery of the enantiomers from eluted fractions was 40.8–65.6%, yielding 16.4 mg of the S enantiomer and 10.2 mg of the R enantiomer. At the same time, we attempted to enantioseparate the anti‐inflammatory drug loxoprofen by countercurrent chromatography and high‐performance liquid chromatography using a chiral mobile phase additive. However, no successful enantioseparation was achieved so far.  相似文献   

3.
The separation of ten epimeric aromatic acid (−)‐menthol esters by countercurrent chromatography with hydroxypropyl‐β‐cyclodextrin as the mobile phase additive was investigated, and methods for the analysis of all the epimeric esters by reversed‐phase high‐performance liquid chromatography were established. A biphasic solvent system composed of n‐hexane/20–70% methanol containing 50 mmol/L of hydroxypropyl‐β‐cyclodextrin (1:1, v/v) was selected, which provided high separation factors for five of the epimeric esters, and successful separations by countercurrent chromatography were achieved. The complete separation of five pairs of epimeric ester was obtained with the purity being over 98% for each peak fractions, as determined by high‐performance liquid chromatography. The recovery of each analyte from the eluted fractions reached around 80–88%.  相似文献   

4.
High‐speed countercurrent chromatography (HSCCC) combined with biphasic chiral recognition was successfully applied to the resolution of phenylsuccinic acid enantiomers. d ‐Isobutyl tartrate and hydroxypropyl‐β‐cyclodextrin were employed as lipophilic and hydrophilic selectors dissolved in the organic stationary phase and aqueous mobile phase, respectively. The two‐phase solvent system was made up of n‐hexane/methyl tert‐butyl ether/water (0.5:1.5:2, v/v/v). Impacts of the type and concentration of chiral selectors, the pH value of the aqueous phase solution as well as the temperature on the separation efficiency were investigated. By means of preparative HSCCC, pure enantiomer was obtained by separating 810 mg of racemate with a purity >99.5% and a recovery rate between 82 and 85%. The experimental results indicate that biphasic recognition HSCCC provide a promising means for efficient separation of racemates.  相似文献   

5.
This work concentrates on extending the utilization of multiple dual mode (MDM) counter‐current chromatography in chiral separations. Two aromatic acids, 2‐(6‐methoxy‐2‐naphthyl)propionic acid (NAP) and 2‐phenylpropionic acid (2‐PPA), were enantioseparated by MDM counter‐current chromatography using hydroxypropyl‐β‐cyclodextrin (HP‐β‐CD) as chiral selector. The two‐phase solvent systems consisting of n‐hexane/ethyl acetate 0.1 mol/L phosphate buffer pH 2.67 containing 0.1 mol/L HP‐β‐CD (7.5:2.5:10 for NAP and 7:3:10 for 2‐PPA, v/v/v) were used. Conventional MDM and modified MDM were compared according to peak resolution under current separation mechanism. The influence of elution time after the first‐phase inversion and number of cycles for MDM were investigated. Peak resolution of NAP and 2‐PPA increased from 0.62 to 1.05 and 0.72 to 0.84, respectively, using optimized MDM conditions. Being an alternative elution method for counter‐current chromatography, MDM elution greatly improved peak resolution in chiral separations.  相似文献   

6.
Recycling high‐speed counter‐current chromatography was successfully applied to the preparative separation of oxybutynin enantiomers. The two‐phase solvent system consisted of n‐hexane, methyl tert‐butyl ether, and 0.1 mol/L phosphate buffer solution (pH = 5.0) with the volume ratio of 6:4:10. Hydroxypropyl‐β‐cyclodextrin was employed as the chiral selector. The influence of factors on the chiral separation process, including the concentration of chiral selector, the equilibrium temperature, the pH value of the aqueous phase were investigated. Under optimum separation conditions, 15 mg of oxybutynin racemate was separated with the purities of both the enantiomers over 96.5% determined by high‐performance liquid chromatography. Recovery for the target compounds reached 80–82% yielding 6.00 mg of (R)‐oxybutynin and 6.15 mg of (S)‐oxybutynin. Technical details for recycling elution mode were discussed.  相似文献   

7.
Acetyltropic acid is an important synthetic intermediate for preparation of tropane alkaloid derivatives, which can be used as anticholinergic drugs, deliriants, and stimulants. In the present work, acetyltropic acid was successfully enantioseparated by countercurrent chromatography using sulfobutyl ether‐β‐cyclodextrin as chiral selector. A biphasic solvent system composed of n‐butyl acetate/n‐hexane/0.1 mol/L citrate buffer at pH = 2.2 containing 0.1 mol/L of sulfobutyl ether‐β‐cyclodextrin (7:3:10, v/v) was selected, which produced a suitable distribution ratio D= 1.14, D= 2.31 and a high enantioseparation factor α = 2.03. Baseline separation was achieved for preparative enantioseparation of 50 mg of racemic acetyltropic acid. A method for chiral analysis of acetyltropic acid by conventional reverse phase liquid chromatography with hydroxylpropyl‐β‐cyclodextrin as mobile phase additive was established, and formation constants of inclusion complex were determined. It was found that different substituted β‐cyclodextrin should be selected for enantioseparation of acetyltropic acid by countercurrent chromatography and reverse phase liquid chromatography.  相似文献   

8.
An efficient method for the simultaneous enantioseparation of cyproconazole, bromuconazole, and diniconazole enantiomers was developed by CD‐modified MEKC using a dual mixture of neutral CDs as chiral selector. Three neutral CDs namely hydroxypropyl‐β‐CD, hydroxypropyl‐γ‐CD, and γ‐CD were tested as chiral selectors at different concentrations ranging from 10, 20, 30 and 40 mM, but enantiomers of the studied fungicides were not completely separated. The best dual chiral recognition mode for the simultaneous separation of cyproconazole, bromuconazole, and diniconazole enantiomers was achieved with a mixture of 27 mM hydroxypropyl‐β‐CD and 3 mM hydroxypropyl‐γ‐CD in 25 mM phosphate buffer (pH 3.0) containing 40 mM SDS to which methanol‐acetonitrile (10%:5% v/v) was added as organic modifiers. The best separation was based on the appearance of 10 peaks simultaneously, with good resolution (Rs 1.1–15.9), and peak efficiency (N>200 000). Good repeatabilities in the migration time, peak area, and peak height were obtained in terms of RSD ranging from (0.72 to 1.06)%, (0.39 to 3.49)%, and (1.90 to 4.84)%, respectively.  相似文献   

9.
A simple procedure for the synthesis of three new oxazolinyl‐substituted β‐cyclodextrins (6‐deoxy‐6‐R‐(–)‐4‐phenyl‐4,5‐dihydrooxazolinyl‐β‐cyclodextrin, 6‐deoxy‐6‐S‐(–)‐4‐phenyl‐4,5‐dihydrooxazolinyl‐β‐cyclodextrin, and 6‐deoxy‐6‐S‐(–)‐(4‐pyridin‐1‐ium‐4‐methyl‐benzenesulphonate)‐4,5‐dihy‐drooxazolinyl‐β‐cyclodextrin) and their covalent bonding to silica are reported. The ability of these chiral stationary phase columns for separating compounds is also presented and discussed. Twenty‐eight compounds were examined in the polar‐organic mobile phase mode, and 11 β‐nitroethanols were tested in the reversed‐phase mode. Excellent enantioseparations were achieved for most of the analytes, even for several challenging compounds. The rigid and flexible structures of mono‐substituted chiral groups and the fragments around the rim of the β‐cyclodextrin cavity played an important role in the separation process. Factors such as π–π stacking, dipole–dipole interactions, ion‐pairing, and steric hindrance effects were found to affect the chromatographic performance. Moreover, the buffer composition, and percentages of organic modifiers in the mobile phase, were investigated and compared. The mechanisms involved in the separation were postulated based on the chromatographic data.  相似文献   

10.
Native cyclofructans and their isopropyl derivatives were studied as chiral selectors in capillary electrophoresis and compared with α‐ and β‐cyclodextrin. R,S‐1,1’‐Binaphthalene‐2,2’‐diyl hydrogen phosphate was used as a model chiral compound. The empirical observation of the enantioselectivity of native cyclofructans and isopropyl derivatives of cyclofructans was described and compared with the cyclodextrins. The influence of methanol and acetonitrile, as the most commonly used organic solvents, and sodium dodecyl sulfate as a micelle forming additive on the separation of R,S‐1,1’‐binaphthalene‐2,2’‐diyl hydrogen phosphate atropisomers was achieved. The different enantiorecognition abilities resulting from unlike interaction mechanism with R,S‐1,1’‐binaphthalene‐2,2’‐diyl hydrogen phosphate were observed for the studied cyclodextrins and cyclofructans, especially when methanol or sodium dodecyl sulfate were used as modifiers of the separation conditions.  相似文献   

11.
New single‐isomer, cationic β‐cyclodextrins, including mono‐6‐deoxy‐6‐pyrrolidine‐β‐cyclodextrin chloride (pyCDCl), mono‐6‐deoxy‐6‐(N‐methyl‐pyrrolidine)‐β‐cyclodextrin chloride (N‐CH3‐pyCDCl), mono‐6‐deoxy‐6‐(N‐(2‐hydroxyethyl)‐pyrrolidine)‐β‐cyclodextrin chloride (N‐EtOH‐pyCDCl), mono‐6‐deoxy‐6‐(2‐hydroxymethyl‐pyrrolidine)‐β‐cyclodextrin chloride (2‐MeOH‐pyCDCl) were synthesized and used as chiral selectors in capillary electrophoresis for the enantioseparation of carboxylic and hydroxycarboxylic acids and dansyl amino acids. The unsubstituted pyCDCl exhibited the greatest resolving ability. Most analytes were resolved over a wide range of pH from 6.0 to 9.0 with this chiral selector. In general, increasing pH led to a decrease in resolution. The effective mobilities of all the analytes were found to decrease with increasing CD concentration. The optimal concentration for most carboxylic acids and dansyl amino acid was in the range 5–7.5 mM and >15 mM for hydroxycarboxylic acids. 1H NMR experiments provided direct evidence of inclusion in the CD cavity.  相似文献   

12.
目的:建立刺激胰岛素分泌的新型降糖药物(-)-2 (S)-苄基-4-酮-4-(顺式-全氢化异吲哚-2-基)丁酸钙对映体的HPLC拆分方法。方法:采用Sumichiral OA-3300手性柱(250 × 4.6 mm I.D., 5 μm), 柱温35℃,以0.05 mol·L-1醋酸铵的甲醇溶液为流动相,检测波长为210 nm。结果:本品两对映体在22分钟内实现良好分离,分离度达3以上,S-异构体分别在0.028 ~ 5.6 μg mL-1和0.03 ~ 6.0 μg mL-1范围内线性关系良好,回归方程分别为:Y=1.32×103x-2.54 (r=0.9997)和Y=1.15×103x-1.78 (r=0.9998),最低检测限分别为0.15 ng和0.10 ng,方法精密度RSD低于1.0% (n=5)。结论:建立的对映体分离方法可用于本品光学异构体的质量控制。  相似文献   

13.
A nanoliquid chromatographic method for the stereoisomer separation of some flavanone aglycones and 7‐O‐glycosides has been proposed employing a C18 capillary column and a chiral mobile‐phase additive such as cyclodextrin. The chiral separation of eriodictyol, naringenin, and hesperitin was obtained by addition of carboxymethyl‐β‐cyclodextrin to the mobile phase, whereas eriocitrin, naringin, narirutin, and hesperidin diastereoisomers were resolved by using sulfobutyl ether‐β‐cyclodextrin. The influence of the composition of the mobile phase, the length of the capillary column, and the flow rate on the chiral recognition were investigated. At optimum conditions, baseline separation for the selected aglycones and glycosylated forms were achieved with a mobile phase consisting of 50 mM sodium acetate buffer pH 3 and 30% methanol containing 20 mM of carboxymethyl‐β‐cyclodextrin and 10 mM of sulfobutyl ether‐β‐cyclodextrin, respectively. Precision, linearity, and sensitivity of the method were tested. Limits of detection and quantification for the studied flavanone glycosides were in the range 1.3‐2.5 and 7.5‐12.5 µg/mL, respectively. The method was used for the determination of the diastereomeric composition of the flavanone‐7‐O‐glycosides in Citrus juices after solid‐phase extraction procedure.  相似文献   

14.
A new member of the family of methoxylalkylamino monosubstituted β‐cyclodextrins, mono‐6A‐(4‐methoxybutylamino)‐6A‐β‐cyclodextrin, has been developed as a chiral selector for enantioseparation in capillary electrophoresis. This amino cyclodextrin exhibited good enantioselectivities for 16 model acidic racemates including three dansyl amino acids at an optimum pH of 6.0. Excellent chiral resolutions over six were obtained for α‐hydroxy acids and 2‐phenoxypropionic acids with 3.0 mM chiral selector. The good chiral recognition for α‐hydroxyl acids was attributed to inclusion complexation, electrostatic interactions, and hydrogen bonding. The hydrogen‐bonding‐enhanced chiral recognition was revealed by NMR spectroscopy. The chiral separation of acidic racemates was further improved with the addition of methanol (≤10 vol%) as an organic additive.  相似文献   

15.
The application of a chiral ligand‐exchange column for the direct high‐performance liquid chromatographic enantioseparation of unusual β‐amino acids with a sodium N‐((R)‐2‐hydroxy‐1‐phenylethyl)‐N‐undecylaminoacetate‐Cu(II) complex as chiral selector is reported. The investigated amino acids were isoxazoline‐fused 2‐aminocyclopentanecarboxylic acid analogs. The chromatographic conditions were varied to achieve optimal separation. The effects of temperature were studied at constant mobile phase compositions in the temperature range 5–45°C, and thermodynamic parameters were calculated from plots of lnk or lnα versus 1/T. Δ(ΔH°) ranged from –2.3 to 2.2 kJ/mol, Δ(ΔS°) from –3.0 to 7.8 J mol?1 K?1 and –Δ(ΔG°) from 0.1 to 1.7 kJ/mol, and both enthalpy‐ and entropy‐controlled enantioseparations were observed. The latter was advantageous with regard to the shorter retention and greater selectivity at high temperature. Some mechanistic aspects of the chiral recognition process are discussed with respect to the structures of the analytes. The sequence of elution of the enantiomers was determined in all cases.  相似文献   

16.
Photoirradiation surface molecularly imprinted polymers for the separation of 6‐O‐α‐d ‐maltosyl‐β‐cyclodextrin were synthesized using functionalized silica as a matrix, 4‐(phenyldiazenyl)phenol as a light‐sensitive monomer, and 6‐O‐α‐d ‐maltosyl‐β‐cyclodextrin as a template. Fourier transform infrared spectroscopy results indicated that 4‐(phenyldiazenyl)phenol was grafted onto the surface of functionalized silica. The obtained imprinted polymers exhibited specific recognition toward 6‐O‐α‐d ‐maltosyl‐β‐cyclodextrin. Equilibrium binding experiments showed that the photoirradiation surface molecularly imprinted polymers obtained the maximum adsorption amount of 6‐O‐α‐d ‐maltosyl‐β‐cyclodextrin at 20.5 mg/g. In binding kinetic experiments, the adsorption reached saturation within 2 h with binding capacity of 72.8%. The experimental results showed that the adsorption capacity and selectivity of imprinted polymers were effective for the separation of 6‐O‐α‐d ‐maltosyl‐β‐cyclodextrin, indicating that imprinted polymers could be used to isolate 6‐O‐α‐d ‐maltosyl‐β‐cyclodextrin from a conversion mixture containing β‐cyclodextrin and maltose. The results showed that the imprinted polymers prepared by this method were very promising for the selective separation of 6‐O‐α‐d ‐maltosyl‐β‐cyclodextrin.  相似文献   

17.
Pressure‐assisted stereospecific capillary electrophoresis method was developed for the determination of enantiomeric purity of the antiparkinsonian agent (R)‐rasagiline. The optimized method, 50 mM glycine‐HCl buffer pH 2, supplied with 30 mM sulfobutylether‐β‐cyclodextrin, at 35°C, applying 12 kV in reversed polarity, and –8 mbar pressure (vacuum), short‐end injection with ‐25 mbar × 2 s, was successful for baseline separation of rasagiline enantiomers (Rs = 3.5 ± 0.1) in a short analysis time. The method was validated according to current guidelines and proved to be reliable, linear, precise and accurate for determination of 0.15% S‐enantiomer as chiral impurity in R‐rasagiline sample, as well as quantification of the eutomer. Method application was tested on a commercial tablet formulation. Determination of spatial structure of diastereomeric associates was based on 1H and 2D ROESY NMR, indicating that the aromatic moiety of the molecule can enter the cyclodextrin cavity. NMR titration and molecular modeling revealed that S‐rasagiline formed a more stable inclusion complex with sulfobutylether‐β‐cyclodextrin, than its antipode, which is in agreement with electrophoretic results.  相似文献   

18.
Facile, alternative synthetic routes to 6 , (R)‐6 , and (S)‐6 ‐3‐benzyl‐N‐(2,6‐dimethylphenyl)‐1,3‐oxazolidine‐4‐carboxamides ( 6 ), a chiral oxazolidine derivative of tocainide, are reported. The synthetic routes described herein also afforded 11 ‐, (R)‐11 ‐, and 12 , which present the imidazolidin‐4‐one core and belong to a class of compounds interesting for their biological activities. All the final compounds and intermediates were fully characterized. Enantiomeric excesses of homochiral 6 and 11 were determined by capillary electrophoresis analysis using 2‐hydroxypropyl‐β‐cyclodextrin or highly sulfated γ‐cyclodextrin as chiral selectors. J. Heterocyclic Chem., (2010)  相似文献   

19.
To further evaluate the feasibility and applicability of the one‐pot strategy in monolithic column preparation, two novel β‐cyclodextrin‐functionalized organic polymeric monoliths were prepared using two β‐cyclodextrin derivatives, i.e. mono(6‐amino‐6‐deoxy)‐β‐cyclodextrin and heptakis(6‐amino‐6‐deoxy)‐β‐cyclodextrin. In this improved method, mono(6‐amino‐6‐deoxy)‐β‐cyclodextrin or heptakis(6‐amino‐6‐deoxy)‐β‐cyclodextrin reacted with glycidyl methacrylate to generate the corresponding functional monomers and were subsequently copolymerized with ethylene dimethacrylate. The polymerization conditions for both monoliths were carefully optimized to obtain satisfactory column performance with respect to column efficiency, reproducibility, permeability, and stability. The obtained poly(glycidyl methacrylate‐mono(6‐amino‐6‐deoxy)‐β‐cyclodextrin‐co‐ethylene dimethacrylate) and poly(glycidyl methacrylate‐heptakis(6‐amino‐6‐deoxy)‐β‐cyclodextrin‐co‐ethylene dimethacrylate) monoliths exhibited a uniform structure, good permeability, and mechanical stability as indicated by scanning electron microscopy and micro‐high‐performance liquid chromatography experimental results. Because of the probable existence of multi‐glycidyl methacrylate linking spacers on the poly(glycidyl methacrylate‐heptakis(6‐amino‐6‐deoxy)‐β‐cyclodextrin‐co‐ethylene dimethacrylate) monolith, the effect of the ratio of glycidyl methacrylate/heptakis(6‐amino‐6‐deoxy)‐β‐cyclodextrin was especially studied, and satisfactory reproducibility could still be achieved by strictly controlling the composition of the polymerization mixture. To investigate the effect of the degree of amino substitution of β‐cyclodextrin on column performance, a detailed comparison of the two monoliths was also carried out using series of analytes including small peptides and chiral acids. It was found that the β‐cyclodextrin‐functionalized monolith with mono‐glycidyl methacrylate linking spacers demonstrated better chiral separation performance than that with multi‐glycidyl methacrylate linking spacers.  相似文献   

20.
A novel single‐isomer cyclodextrin derivative, heptakis {2,6‐di‐O‐[3‐(1,3‐dicarboxyl propylamino)‐2‐hydroxypropyl]}‐β‐cyclodextrin (glutamic acid‐β‐cyclodextrin) was synthesized and used as a chiral selector in capillary electrophoresis for the enantioseparation of 12 basic drugs, including terbutaline, clorprenaline, tulobuterol, clenbuterol, procaterol, carvedilol, econazole, miconazole, homatropine methyl bromide, brompheniramine, chlorpheniramine and pheniramine. The primary factors affecting separation efficiency, which include the background electrolyte pH, the concentration of glutamic acid‐β‐cyclodextrin and phosphate buffer concentration, were investigated. Satisfactory enantioseparations were obtained using an uncoated fused‐silica capillary of 50 cm (effective length 40 cm) × 50 μm id with 120 mM phosphate buffer (pH 2.5–4.0) containing 0.5–4.5 mM glutamic acid‐β‐cyclodextrin as background electrolyte. A voltage of 20 kV was applied and the capillary temperature was kept at 20°C. The results proved that glutamic acid‐β‐cyclodextrin was an effective chiral selector for studied 12 basic drugs. Moreover, the possible chiral recognition mechanism of brompheniramine, chlorpheniramine and pheniramine on glutamic acid‐β‐cyclodextrin was investigated using the semi‐empirical Parametric Method 3.  相似文献   