首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 199 毫秒
1.
《Analytical letters》2012,45(6):1125-1135
Abstract

A HPLC method has been developed to determine the concentrations of SAZ-VII-23 (3-benzoyl-7-isopropyl-3,7-diazabicyclo[3.3.1]nonane HClO4), a novel antiarrhythmic agent, in dog plasma and urine. Plasma treated with acetonitrile and alkalinized urine were extracted with chloroform- propanol (9:1). An aliquot was injected on to HPLC system using a C6 reversed-phase column and acetonitrile-methanol-37.5 mM phosphate buffer, pH 6.8 (28.5:28.5:43 v/v) containing 4.0 mM triethylamine as mobile phase. Detection wavelength was 255 nm. The linear range were 0.04–8 μg/ml, and the lower limit of quantitation was 0.04 μg/ml in plasma and urine, respectively. The method was applied to determine plasma and urine concentrations and preliminary pharmacokinetic profiles of SAZ-VII-23 in a dog.  相似文献   

2.
Lamotrigine is an investigational anticonsulvant drug undergoing clinical trials. A simultaneous assay was developed to quantitate lamotrigine and its major metabolite, lamotrigine 2-N-glucuronide, from guinea pig whole blood. The extraction procedure and reversed-phase high-performance liquid chromatographic (HPLC) assay employed sodium dodecylsulfate (SDS) as an ion-pairing reagent to selectively separate lamotrigine and lamotrigine 2-N-glucuronide from endogenous blood components, other anti-convulsant drugs, and their metabolites. The mobile phase was composed of acetonitrile-50 mM phosphoric acid (pH 2.2) containing 10 mM SDS (33:67, v/v), and components were detected at 277 nm. The total coefficients of variance (C.V.) for the blood assay were less than or equal to 9.4% for lamotrigine (0.25-20.0 micrograms/ml) and less than or equal to 13.4% for the glucuronide metabolite (0.25-10.0 micrograms/ml). Separate assays for lamotrigine and its glucuronide in urine were developed. In order to quantitate low levels of lamotrigine in guinea pig urine, lamotrigine was extracted with tert.-butyl methyl ether-ethyl acetate (1:1). The total C.V. for lamotrigine quantitation in urine was less than or equal to 7.5% (0.10-10.0 micrograms/ml). For the determination of lamotrigine 2-N-glucuronide, urine was diluted with an SDS-phosphoric acid buffer (1:4) and injected directly onto the HPLC system, total C.V. less than or equal to 4.2% (0.5-50 micrograms/ml).  相似文献   

3.
A novel high-performance liquid chromatographic method for the determination of codeine, norcodeine and morphine in plasma and urine has been developed. The compounds were separated on a cyano column (15 cm x 4.6 mm, 5 microns particle size) using a mobile phase of acetonitrile-triethylamine-distilled water (4:0.1:95.9, v/v) pH 3.1 and then determined by fluorescence detection. Calibration curves in the range 5-200 ng/ml for plasma and 0.1-10 micrograms/ml for urine were linear and passed through the origin. The imprecision and inaccuracy of the assay were less than 10% and the limits of detection were 2 ng/ml for all three compounds in human plasma.  相似文献   

4.
A rapid, simple and sensitive column-switching high-performance liquid chromatographic procedure for the determination of captopril in plasma and urine had been developed. p-Bromophenacyl bromide was used as a derivatizing reagent to react with captopril to form a product that showed ultraviolet-absorbing properties. For plasma samples the protein was removed with 6% perchloric acid before injection. The urine samples were directly injected into the chromatograph. The column-switching system was equipped with a pre-column (5 cm x 0.5 cm I.D.) packed with muBondapak C18 (37-50 microns) and an analytical column (15 cm x 0.5 cm I.D.) packed with YWG-C18, 10 microns. Impurities were washed from the pre-column with 0.2% acetic acid and the retained substances were eluted into the analytical column with acetonitrile-water-acetic acid (35:65:0.4, v/v). Captopril was detected at 260 nm. The calibration curve was linear in the range 20-1000 ng/ml for plasma and 10-200 micrograms/ml for urine. The recoveries averaged 103.2 and 99.5% for plasma and urine, respectively. The coefficients of variation were all less than 10%.  相似文献   

5.
A quantitative method for the simultaneous high-performance liquid chromatographic (HPLC) resolution and determination of the enantiomers of 5-dimethylsulphamoyl-6,7-dichloro-2,3-dihydrobenzofuran-2-carboxyl ic acid, a new diuretic, and its N-monodemethylated metabolite in monkey plasma and urine is described. The method includes diethyl ether extraction of the samples and S-(-)-alpha-methylbenzylamide derivatization of the extract, followed by reversed-phase solid-phase extraction and injection of the resulting diastereoisomers onto a reversed-phase HPLC column. Baseline separation was obtained. The assay showed linearity over the range 0.1-50 micrograms/ml of plasma and 0.25-500 microliters of urine, with a lower limit of detection of ca. 0.01 micrograms/ml for each of the enantiomers. The method is adequate for pharmacokinetic and enantioselective disposition studies of both the diuretic and its metabolite.  相似文献   

6.
A rapid, sensitive and specific high-performance liquid chromatographic (HPLC) assay was developed for the determination of 8-chloro-6-(2-chlorophenyl)-4H-imidazo-[1,5-alpha]-[1,4]-benzodiazepine-3-carboxamide [I] and its 4-hydroxy metabolite, 8-chloro-6-(2-chlorophenyl)-4-hydroxy-4H-imidazo-[1,5-alpha] [1,4]-benzodiazepine-3-carboxamide [II] in whole blood, plasma or urine. The assay for both compounds involves extraction into diethyl ether-methylene chloride (70:30) from blood, plasma, or urine buffered to pH 9.0. The overall recoveries of [I] and [II] are 92.0 +/- 5.4% (S.D.) and 90.3 +/- 4.9% (S.D.), respectively. The sensitivity limit of detection is 50 ng/ml of blood, plasma, or urine using a UV detector at 254 nm. The HPLC assay was used to monitor the blood concentration-time fall-off profiles, and urinary excretion profiles in the dog following single 1 mg/kg intravenous and 5 mg/kg oral doses, and following multiple oral doses of 100 mg/kg/day of compound [I].  相似文献   

7.
A high-performance liquid chromatographic method for the quantification of rufloxacin in human serum and urine has been developed and validated. The compounds, rufloxacin and internal standard, are extracted from buffered serum and urine using dichloromethane. They are then separated on an anion-exchange column using 0.05 M phosphate buffer-acetonitrile (80:20, v/v). The eluate is quantified by measuring the ultraviolet absorbance at 296 nm. The lower limit of detection for the analyte is 0.1 microgram/ml in serum and 0.05 micrograms/ml in urine. The method is linear from 0.3 to 10 micrograms/ml for serum and 0.1 to 10 micrograms/ml for urine. The method has been applied in a pharmacokinetic study in volunteers.  相似文献   

8.
A method is described for the extraction of a phosphonic acid angiotensin-converting enzyme inhibitor from either urine or plasma, and subsequent quantitation using high-performance liquid chromatographic (HPLC) analysis and post-column o-phthalaldehyde reagent derivatization. The compound cannot be quantitatively extracted from the body fluids, but use of a fluorinated internal standard allowed for the computation of accurate results. With the use of an internal standard, excellent precision, linearity, and recovery were obtained for analyte response in both urine and plasma. In urine a working range of 0.2-10 micrograms/ml was found, with a limit of detection of 0.1 micrograms/ml. For plasma the working range was found to be 2-500 ng/ml, and the limit of detection was established as 1 ng/ml. Due to the non-polar character of the analyte at low pH values, it was possible to use novel extraction (solid-phase C8 column) and HPLC [poly(styrenedivinyl benzene) HPLC column] conditions to separate and quantitate the compound from plasma and urine.  相似文献   

9.
A reversed-phase high-performance liquid chromatographic (HPLC) method has been developed for the determination of neomycin in plasma and urine. The plasma was deproteinated with trichloroacetic acid and centrifuged. The supernatant was mixed with ion-pair concentrate and centrifuged again. The resultant supernatant was analyzed by HPLC. Urine was centrifuged to remove debris, if any, mixed with ion-pair concentrate and analyzed directly by HPLC. The HPLC conditions consisted of an ion-pairing mobile phase, a reversed-phase column, post-column derivatization with o-phthalaldehyde (OPA) reagent and fluorescence detection. The overall average recovery of neomycin was 97 and 113% from plasma spiked at 0.25-1.0 micrograms/ml, using standard curves prepared in plasma extract and in water, respectively, and 94% for urine spiked at 1-10 micrograms/ml using a standard curve prepared in water. The method was used to detect neomycin in plasma and urine obtained from animals injected intramuscularly with neomycin. Various pharmacokinetic parameters of neomycin were also determined from its profile of plasma concentration versus time.  相似文献   

10.
A high-performance liquid chromatographic method for the determination of the histamine H1-receptor antagonist cetirizine in human urine was developed. Cetirizine and the internal standard are extracted from acidified (pH 5) urine (0.5 ml) into chloroform and the organic layer is evaporated to dryness. The residue is chromatographed on a Spherisorb 5ODS-2 column using Pic A (5 mM aqueous tetrabutylammonium phosphate)-methanol-tetrahydrofuran (33:65:2, v/v) as the mobile phase with ultraviolet detection (230 nm). The calibration graph is linear from 0.1 to 10 micrograms/ml and using 0.5 ml of urine the detection limit is 20 ng/ml. The within-run relative standard deviation is less than 6% and the accuracy is within 10% of the theoretical value at concentrations between 0.1 and 10 micrograms/ml in urine. There is a good correlation (r = 0.99606) with a previously described capillary gas chromatographic assay.  相似文献   

11.
A HPLC-UV method has been developed for assaying rifampicin in plasma and liver. The assay involved a liquid-liquid extraction procedure with dichloromethane-pentane (1:1). An Ultrabase-C18 column and a simple mobile phase consisting of a water (pH 2.27)-acetonitrile (40:60, v/v) mixture were used. The flow-rate was 1 ml/min and the effluent was monitored at 333 nm. Results from the HPLC analyses showed that the assay method is linear in the ranges 0.1-1 and 1-50 microg/ml for plasma, and 0.6-40 microg/g for liver. Intra- and inter-day R.S.D. were below 15% for all the sample types. Recoveries averaged 83 and 95% for plasma and liver, respectively. The method is being successfully applied to determine rifampicin in plasma and liver samples taken during pharmacokinetic studies in rats.  相似文献   

12.
High-performance liquid chromatographic methods for quantification of a novel carbapenem anti-infective agent, I, in plasma and urine have been developed, validated, and applied to clinical samples. The carbapenem is stabilized in the matrix by the addition of a non-nucleophilic buffer, rapid freezing, and storage at -70 degrees C. After addition of another carbapenem, II, as internal standard, plasma proteins are precipitated with acetonitrile, which is subsequently extracted from the sample with methylene chloride. A portion of the aqueous phase is injected onto a reversed-phase phenyl column that is eluted with 4% (v/v) acetonitrile in 15 mM ammonium phosphate (pH 7.4). The urine assay entails addition of the internal standard II to buffered urine, which is subsequently extracted with methylene chloride prior to injection of the aqueous phase onto a cation-exchange column. The urine assay mobile phase is 5% v/v tetrahydrofuran in 100 mM sodium acetate (pH 5.4). The detector response at 313 nm is a linear (r greater than 0.99) function of concentration over the ranges 0.50-100 micrograms/ml and 2.0-200 micrograms/ml for the plasma and urine assays, respectively. Thermal degradation products do not interfere with either assay. These assays have proven to be accurate, precise, reproducible, and rugged during clinical sample analyses.  相似文献   

13.
A high-performance liquid chromatographic (HPLC) method for the determination of sulbactam in human and rat plasma and urine has been developed. Sulbactam was reacted with 1,2,4-triazole to yield a product having an ultraviolet absorption maximum at 326 nm. The product was separated using reversed-phase HPLC from the regular components of plasma and urine with an ion-pair buffer at 50 degrees C and detected at the ultraviolet maximum. The limits of accurate determination were 0.2 and 1.0 micrograms/ml in plasma and urine, respectively. The coefficients of variation of inter- and intra-assays in human plasma spiked at 4.0 micrograms/ml (n = 5) were 1.02 and 3.05%, respectively. Coexisting cefoperazone, penicillins, or the alkaline degradation product(s) of sulbactam did not interfere in the sulbactam assay. The pharmacokinetic behaviour of sulbactam and cefoperazone coadministered to rats was estimated by moment analysis.  相似文献   

14.
A method was developed for the quantitative analysis of the novel anticancer agent ES-285 (spisulosine; free base) in human, mouse, rat, and dog plasma using high-performance liquid chromatography/electrospray ionization tandem mass spectrometry in order to support pre-clinical and clinical studies with the drug. Sample preparation was carried out by protein precipitation with acetonitrile, containing isotopically labeled (d(3)) ES-285 as internal standard. Aliquots of 10 micro l of the supernatant were injected directly on to an Inertsil ODS-3 column (50 x 2.0 mm i.d., 5 micro m). Elution was carried out using methanol-10 mM ammonium formate (pH 4) in water (80 : 20, v/v) pumped at a flow-rate of 0.2 ml min(-1) with a run time of 8 min. Multiple reaction monitoring chromatograms obtained on an API365 triple-quadrupole mass spectrometer were used for quantification. The lower limit of quantitation (LLOQ) was 10 ng ml(-1) in human, mouse, rat, and dog plasma and the linear dynamic range extended to 500 ng ml(-1). A full validation of the method was performed in human plasma, and partial validations were performed in mouse, rat and dog plasma. Accuracies and precisions were <20% at the LLOQ concentration and <15% for all other concentrations in all matrices. ES-285 was stable during all steps of the assay. Thus far this method has been used successfully to analyze over 500 samples in pre-clinical trials, and will be implemented in the planned clinical phase I studies.  相似文献   

15.
A high-performance liquid chromatographic method for the determination of picotamide in human plasma and urine is described. After addition of an internal standard (bamifylline), the plasma and urine samples were subjected to liquid-liquid extraction and clean-up procedures. The final extracts were evaporated to dryness and the resulting residues were reconstituted in 100 microliters of methanol-water (50:50, v/v) and chromatographed on a LiChrosorb RP-SELECT B reversed-phase column coupled to an ultraviolet detector monitored at 230 nm. Chromatographic analysis takes about 10 min per sample. The assay was linear over a wide range and has a limit of detection of 0.005 and 0.1 micrograms/ml in plasma and urine, respectively. It was selective for picotamide, accurate and robust and thus suitable for routine assays after therapeutic doses of picotamide.  相似文献   

16.
A rapid, sensitive and specific high-performance liquid chromatographic (HPLC) assay was developed for the determination of amdinocillin (formerly mecillinam) in human plasma and urine. The assay is performed by direct injection of a plasma protein-free supernatant or a dilution of urine. A 10 micrometer muBondapak phenyl column with an eluting solvent of water--methanol--1 M phosphate buffer, pH 7 (70:30:0.5) was used, with UV detection of the effluent at 220 nm. Azidocillin potassium salt [potassium-6-(D-(-)-alpha-azidophenyacetamido)-penicillanate] was used as the internal standard and quantitation was based on peak height ratio of amdinocillin to that of the internal standard. The assay has a recovery of 74.4 +/- 6.3% (S.D.) in the concentration ranges of 0.1-20 microgram per 0.2 ml of plasma with a limit of detection equivalent to 0.5 microgram/ml plasma. The urine assay was validated over a concentration range of 0.025-5 mg/ml of urine, and has a limit of detection of 0.025 mg/ml (25 microgram/ml) using a 0.1-ml urine specimen per assay. The assay was applied to the determination of plasma and urine concentrations of amdinocillin following intravenous administration of a 10 mg/kg dose of amdinocillin to two human subjects. The HPLC and microbiological assays were shown to correlate well for these samples.  相似文献   

17.
A sensitive, selective, and rapid high-performance liquid chromatographic procedure was developed for the determination of isoxicam in human plasma and urine. Acidified plasma or urine were extracted with toluene. Portions of the organic extract were evaporated to dryness, the residue dissolved in tetrahydrofuran (plasma) or acetonitrile (urine) and chromatographed on a mu Bondapak C18 column preceded by a 4-5 cm X 2 mm I.D. column packed with Corasil C18. Quantitation was obtained by UV spectrometry at 320 nm. Linearity in plasma ranged from 0.2 to 10 micrograms/ml. Recoveries from plasma samples seeded with 1.8, 4 and 8 micrograms/ml isoxicam were 1.86 +/- 0.077, 4.10 +/- 0.107 and 8.43 +/- 0.154 micrograms/ml with relative standard deviations of 3.3%, 2.5% and 5.4%, respectively. The linearity in urine ranged from 0.125 to 2 micrograms/ml. The precision of the method was 3.3-9.0% relative standard deviation over the linear range.  相似文献   

18.
A sensitive and reproducible high-performance liquid chromatographic method was developed to assay ampherotericin B in plasma, blood, urine and various tissue samples. Amphotericin B was isolated from each sample matrix by solid-phase extraction (Bond-Elut). The eluate from Bond-Elut containing amphotericin B was injected onto a reversed-phase C18 column (Waters, mu Bondpak, 10 microns, 300 mm x 3.9 mm I.D.) with a mobile phase of 45% acetonitrile in 2.5 mM Na2EDTA at 1 ml/min. Detection of amphotericin B was by ultraviolet absorption at 382 nm. Blood and tissues were homogenized and extracted with methanol prior to Bond-Elut extraction. The extraction efficiencies of amphotericin B from plasma, blood and tissues were approximately 90, 70 and 75%, respectively. The sensitivity of the assay was less than or equal to 5 ng/ml for plasma, less than or equal to 25 ng/ml for blood, 2.5 ng/ml for urine and 50 ng/g for tissues. The linearity of the assay method was up to 2.5 micrograms/ml for plasma, 5 micrograms/ml for blood, 500 ng/ml for urine and 500 micrograms/g for tissues. The assay was reproducible with an intra-day coefficient of variation (C.V., n = 3) of less than 5% in general for plasma, blood and tissues. The inter-day C.V. of the assay was less than 5% for plasma (n = 5), less than 10% for blood (n = 4) and less than 5% for tissues (n = 3). The overall variability in the urine assay was generally less than 10%. This method has demonstrated significant improvement in the sensitivity and reproducibility in assaying amphotericin B in plasma and especially in blood, urine and tissues. We have employed this assay to compare the pharmacokinetic and tissue distribution profiles of amphotericin B in rats and dogs following administration of Fungizone and ABCD (amphotericin B-cholesteryl sulfate colloidal dispersion), a lipid-based dosage form. In addition, the assay method for plasma and urine samples can also be applied to pharmacokinetics studies of amphotericin B in man.  相似文献   

19.
A rapid and sensitive high-performance liquid chromatographic procedure was developed for the analysis of the new, long-acting neuromuscular blocker doxacurium in the plasma and urine of dog and man and in the bile of dog. Samples were prepared on solid-phase extraction cartridges containing a methyl (C1) bonded phase and were chromatographed on a 15 cm reversed-phase column (C1) using a mobile phase of 0.05 M monobasic potassium phosphate-acetonitrile (30:70, v/v). The compound was detected at 210 nm with a lower limit of quantitation of 10 ng/ml. An inter-assay accuracy of 90-92% was obtained for the analysis of the drug from biological fluids. The method was applied to studies of doxacurium after intravenous administration to dog and man.  相似文献   

20.
A rapid, sensitive and selective method was developed for the determination of a novel steroidal androgen receptor antagonist (Win 49596, I) in human plasma. The procedure involved extraction from plasma using a solid-phase phenyl support and elution directly onto a reversed-phase C8 column using a mobile phase consisting of 0.2 mol/l sodium acetate buffer at pH 7-acetonitrile (45:55, v/v). Drug was monitored by ultraviolet detection at a wavelength of 238 nm. Linear responses were observed for standards over the range 0.01-5.0 micrograms/ml. The minimum quantifiable level was 0.02 microgram/ml, using a 0.5-ml plasma sample. The precision was 5.5% and the accuracy ranged from -9.4% to 0.23%. The analytical method has been used to quantify I in plasma from dogs and rats and is projected for use with human plasma from clinical trials.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号