首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 109 毫秒
1.
In this paper, we described a simple and rapid method, capillary electrophoresis with electrochemiluminescence (CE–ECL) detection using tris(2,2′-bipyridyl)ruthenium(II) (Ru(bpy)32+), to simultaneously detect pethidine and methadone. Analytes were injected to separation capillary of 67.5 cm length (25 μm i.d., 360 μm o.d.) by electrokinetic injection for 10 s at 10 kV. Under the optimized conditions: ECL detection at 1.20 V, 30 mM sodium phosphate (pH 6.0) as running buffer, separation voltage at 14.0 kV, 5 mM Ru(bpy)32+ with 50 mM sodium phosphate (pH 6.5) in the detection cell, the linear range from 2.0 × 10− 6 to 2.0 × 10− 5 M for pethidine and 5.0 × 10− 6 to 2.0 × 10− 4 M for methadone and detection limits of 0.5 μM for both of them were achieved (S/N = 3). Relative standard derivations of the ECL intensity were 2.09% and 6.59% for pethidine and methadone, respectively.  相似文献   

2.
In this study a PVC membrane electrode for determination of ketotifen fumarate is reported, where ketotifen tetraphenylborate (Keto-TPB) was used as ion exchanger. The electrode has linear range of 5.6 × 10− 6–1.0 × 10− 2 and 1.0 × 10− 5–1.0 × 10− 2 mol/L, with detection limits 2.37 × 10− 6and 4.60 × 10− 6 mol/L in batch and flow injection analysis (FIA), respectively. The electrodes show a Nernstian slope value (58.40 and 61.50 mV/decade in batch and FIA, respectively), and the response time is very short (≤ 10 s). The potential is nearly stable over the pH range 2.0–8.0. Selectivity coefficient values towards different inorganic cations, sugars and amino acids reflect high selectivity of the prepared electrodes. These are used for determination of Ketotifen using potentiometric titration and standard addition methods in pure samples and its pharmaceutical preparations (Zaditen tablets and syrup). The average recovery values are 99.5 and 99.2% with RSD 1.4 and 1.2% for potentiometric titrations and standard addition methods, respectively. The electrode response at different temperatures was also studied.  相似文献   

3.
Gold nanorods (GNRs) with suitable aspect ratio were synthesized with a template technique and then dispersed in a saturated sodium citrate solution by ultrasonication to form a GNR suspension. A GNR-modified electrode was fabricated using the GNR suspension. The oxidation of dopamine at the GNR/GC electrode exhibited surprisingly high electrocatalytic activity and adsorption-controlled characteristics. Square-wave voltammetry was used to detect dopamine. At the GNR/GC electrode, the linear concentration range of DA is from 1 × 10−8 M to 1 × 10−7 M and the detection limit (s/n = 3) is as low as 5.5 × 10−9 M. The current sensitivity is 3.280 μA/μM, and 1000-fold ascorbic acid (AA) cannot interfere with the determination of DA. All these performances are greatly superior to those of the bare GC electrode.  相似文献   

4.
Some organosulphur ligands have been found to inhibit the mercury(II) catalyzed substitution of cyanide in hexacyanoferrate(II) by N-methylpyrazinium ion (Mpz+). The inhibitory effect is due to the binding tendency of catalyst Hg2+ with these inhibitors. This effect has been used as a basis to develop a kinetic method for the determination of trace amounts of two organosulphur ligands viz. cysteine and MNDT. The reaction was followed spectrophotometrically at 655 nm by measuring the decrease in absorbance of the product [Fe(CN)5Mpz]2−. The influence of the reaction variables has also been studied. A general mechanistic scheme of the indicator reaction system including the role of inhibitor has been proposed and applied to determine the organosulphur ligands. Under the selected experimental conditions cysteine and MNDT have been determined in the range of 2–20 × 10− 7 M and 5 × 10− 8 M to 12 × 10− 7 M respectively in various aqueous samples. The analytical concentration range depends upon the amount of Hg2+ present in the indicator reaction and also on the stability of the Hg2+-inhibitor complex in question. Under specified conditions, the detection limit for cysteine and MNDT are 2 × 10− 7 M and 5 × 10− 8 M respectively. The influences of possible interference by major amino acids, on the determination of cysteine and their limits have been investigated.  相似文献   

5.
《Electroanalysis》2005,17(18):1681-1686
Adsorptive‐stripping voltammetry and chronopotentiometry were used to study the adsorption and oxidation of quercetin at both graphite‐nujol paste electrode (GPE) and carbon nanotubes‐nujol paste electrode (CNTPE) for the potential application of carbon nanotube to flavonoids determination. As compared with GPE, CNTPE showed very great power to adsorb quercetin and resulted in a considerable signals enhancement. The adsorption isotherm of quercetin on CNTPE was of Langmuir type, and the stripping of quercetin adsorbed on CNTs showed a quasi‐reversible oxidation reaction involving two‐electron and two‐proton. The high adsorbtive activity of CNTPE was contributed to the high specific surface area and the special surface characteristics of carbon nanotubes. The peak current response of differential pulse voltammetry depended linearly on quercetin concentration. A linear equation Ip(μA)=0.987c(μmol L?1)+0.023 with a correlation coefficient of 0.994 was obtained over the concentration range 0.1–1.0 μmol L?1.  相似文献   

6.
A new approach for decreasing the detection limit for a copper(II) ion-selective electrode (ISE) is presented. The ISE is designed using salicylidine-functionalized polysiloxane in carbon paste. This work describes the attempts to develop the electrode and measurements of its characteristics. The new type of renewable three-dimensional chemically modified electrode could be used in a pH range of 2.3–5.4, and its detection limit is 2.7 × 10−8 mol L−1 (1.2 μg L−1). This sensor exhibits a good Nernstian slope of 29.4 ± 0.5 mV/decade in a wide linear concentration range of 2.3 × 10−7 to 1.0 × 10−3 mol L−1 of Cu(II). It has a short response time (8 s) and noticeably high selectivity over other Cu(II) selective electrodes. Finally, it was satisfactorily used as an indicator electrode in complexometric titration with EDTA and determination of copper(II) in miscellaneous samples such as urine and various water samples.  相似文献   

7.
The preparation and electrochemical characterization of a carbon paste electrode modified with copper(II) hexacyanoferrate(III) (CuHCF) as well as its behavior as electrocatalyst toward the oxidation of N-acetylcysteine were investigated. The electrochemical behavior of the modified electrode and the electrooxidation of N-acetylcysteine were explored using sweep linear voltammetry. The best voltammetric response was observed for a paste composition of 20% (w/w) copper(II) hexacyanoferrate(III) complex, acetate buffer solution at pH of 6.0 as the electrolyte and scan rate of 10 mV s− 1. A linear voltammetric response for N-acetylcysteine was obtained in the concentration range from 1.2 × 10− 4 to 8.3 × 10− 4 mol L− 1, with a detection limit of 6.3 × 10− 5 mol L− 1. The proposed electrode is useful for the quality control and routine analysis of N-acetylcysteine in pharmaceutical formulations.  相似文献   

8.
A poly-amidosulfonic acid and multi-wall carbon nanotubes composite (PASA/MWNTs) modified electrode has been constructed by electropolymerization on glassy carbon electrode (GCE). The electrochemical behaviors of hydroquinone (HQ) and catechol (CC) were investigated using cyclic and differential pulse voltammetries (DPVs) at the prepared electrode. Separation of the reductive peak potentials for HQ and CC was about 120 mV in pH 6.0 phosphate buffer solution (PBS), which makes it suitable for simultaneous determination of these compounds. In the presence of 1.0 × 10−4 mol L−1 isomer, the reductive peak currents of DPV are proportional to the concentration of HQ in the range of 6.0 × 10−6 to 4.0 × 10−4 mol L−1, and to that of CC in the range of 6.0 × 10−6 to 7.0 × 10−4 mol L−1. When simultaneously changing the concentration of both HQ and CC, the linear concentration range of HQ (or CC) is 6.0 × 10−6 to 1.0 × 10−4 mol L−1 (or 6.0 × 10−6 to 1.8 × 10−4 mol L−1), and the corresponding detection limits are 1.0 × 10−6 mol L−1. The proposed method has been applied to simultaneous determination of HQ and catechol in water sample, and the results are satisfactory.  相似文献   

9.
The characteristics, performance, and application of an electrode, namely, Pt|Hg|Hg2(IBP)2|Graphite, where IBP stands for ibuprofenate ion, are described. This electrode responds to IBP with sensitivity of (58.6 ± 0.9) mV decade 1 over the range 5.0 × 10 5–1.0 × 10 1 mol L 1 at pH 6.0–9.0 and a detection limit of 3.8 × 10 5 mol L 1. The electrode is easily constructed at a relatively low cost with fast response time (within 15–30 s) and can be used for a period of 5 months without any considerable divergence in potentials. The proposed sensor displayed good selectivity for ibuprofen in the presence of several substances, especially concerning carboxylate and inorganic anions. It was used for the direct assay of ibuprofen in commercial tablets by means of the standard additions method. The analytical results obtained by using this electrode are in good agreement with those given by the United States Pharmacopeia procedure.  相似文献   

10.
Quantum dots (QDs) or semiconductor nanocrystals have been receiving great interest in the last few years. In this paper, L-cysteine-coated CdSe/CdS core-shell QDs (λem = 585 nm) have been prepared, which have excellent water-solubility. The full width at half maximum (FWHM) of the photoluminescence of these nanocrystals is very narrow (about 30 nm), and the quantum yield (QY) is 15% relative to Rhodamine 6G in ethanol (QY = 95%). With excess free L-cysteine in the solution, the fluorescence intensity of L-cysteine-coated CdSe/CdS QDs showed improved stability. It was found that the fluorescence of L-cysteine-capped CdSe/CdS QDs could be quenched only by copper (II) ions and was insensitive to other physiologically important cations, such as Ca2+, Mg2+, Zn2+, Al3+, Fe3+, Mn2+ and Ni2+ etc. Based on this finding, the quantitative analysis of Cu2+ with L-cysteine-capped CdSe/CdS QDs has been established. The linear range was from 1.0 × 10− 8 to 2.0 × 10− 7 mol L− 1 and the limit of detection (LOD) was 3.0 × 10− 9 mol L− 1 (S/N = 3). The proposed method has first been applied to the determination of Cu2+ in vegetable samples with recoveries of 99.6–105.8%.  相似文献   

11.
A novel taurine modified glassy carbon electrode was prepared by electropolymerization method. The electrochemical behaviors of epinephrine (EP) and dopamine (DA) at the modified electrode were studied by cyclic voltammetry. The modified electrode exhibited enhanced sensitivity and excellent electrochemical discrimination to DA and EP. The cathodic peaks of the two species were well-separated with a potential difference of about 390 mV, so the poly(taurine) modified electrode was used for simultaneous voltammetric measurement of EP and DA by differential pulse voltammetry. Under the optimum conditions, the cathodic peak currents were linear to concentrations of EP and DA in the range of 2.0 × 10−6 to 6.0 × 10−4 mol L−1 and 1.0 × 10−6 to 8.0 × 10−4 mol L−1, respectively. The detection limits for EP and DA were 3.0 × 10−7 and 1.0 × 10−7 mol L−1, respectively. Because the oxidation of ascorbic acid (AA) is an irreversible reaction at modified electrode, the interference of AA for determining EP and DA was eliminated. The modified electrode has been satisfactorily used for the simultaneous determination of EP and DA in pharmaceutical injections.  相似文献   

12.
Herein, a novel electrochemical method was developed for the determination of tryptophan based on the poly(4-aminobenzoic acid) film modified glassy carbon electrode (GCE). The electrochemical behaviors of tryptophan at the modified electrode were investigated. It was found that the oxidation peak current of tryptophan at the modified GCE was greatly improved compared with that at the bare GCE. The effects of supporting electrolyte, pH value, scan rate, accumulation potential and time were examined. The oxidation peak current of tryptophan was proportional to its concentration over the range from 1.0 × 10−6 to 1.0 × 10−4 mol L−1. The limit of detection was evaluated to be 2.0 × 10−7 mol L−1. The proposed method was sensitive and simple. It was successfully employed to determine tryptophan in pharmaceutical samples.  相似文献   

13.
A simple, sensitive, selective and rapid kinetic catalytic method has been developed for the determination of Hg(II) ions at micro-level. This method is based on the catalytic effect of Hg(II) ion on the rate of substitution of cyanide in hexacyanoruthenate(II) with nitroso-R-salt (NRS) in aqueous medium and provides good accuracy and precision. The concentration of Hg(II) catalyst varied from 4.0 to 10.0 × 10−6 M and the progress of reaction was followed spectrophotometrically at 525 nm (λmax of purple-red complex [Ru(CN)5NRS]3−,  = 3.1 × 103 M−1 s−1) under the optimized reaction conditions; 8.75 × 10−5 M [Ru(CN)64−], 3.50 × 10−4 M [nitroso-R-salt], pH 7.00 ± 0.02, ionic strength, I = 0.1 M (KCl), temp 45.0 ± 0.1 °C. The linear calibration curves, i.e. calibration equations between the absorbance at fixed times (t = 15, 20 and 25 min) versus concentration of Hg(II) ions were established under the optimized experimental conditions. The detection limit was found to be 1.0 × 10−7 M of Hg(II). The effect of various foreign ions on the proposed method has also been studied and discussed. The method has been applied to the determination of mercury(II) in aqueous solutions.  相似文献   

14.
Salicylaldehyde rhodamine B hydrazone (SRBH) was developed as a new spectrofluorimetric probe for the selective and sensitive detection of CrO42− in acidic conditions. The proposed method was based on the special oxidation reaction between non-fluorescent SRBH by potassium dichromate to produce a highly fluorescent rhodamine B, as a product. Under the optimum conditions described, the fluorescence enhancement at 591 nm was good linearly related to the concentration of CrO42− from 1.0 × 10−8 to 3.0 × 10−7 M (0.42–12.6 ng mL−1) with a correlation coefficient of R2 = 0.9989 (n = 10) and a detection limit of 1.5 × 10−9 M (0.063 ng mL−1). The relative standard deviation (R.S.D.) was 2.0% (n = 6). The proposed method was also successfully applied to the determination of chromium (VI) in drinking water, river water and synthetic samples.  相似文献   

15.
Heterogeneous electrocatalytic reduction of hydrogen peroxide (H2O2) by C60 is reported for the first time. C60 is embedded in tetraoctylammonium bromide (TOAB) film and is characterized by scanning electron microscopy and cyclic voltammetry. Electrocatalytic studies show that the trianion of C60 mediates the electrocatalytic reduction of H2O2 in aqueous solution containing 0.1 M KCl. Application of such film modified electrode as an amperometric sensor for H2O2 determination is also examined. The sensor shows a fast response within 1 s and a linear response is obtained (R = 0.9986) in the concentration range from 3.33 × 10−5 to 2.05 × 10−3 mol L−1 for H2O2, with the detection limit of 2 × 10−5 mol L−1 and the sensitivity of 1.65 μA mM−1. A good repeatability and stability is shown for the sensor during the experiment.  相似文献   

16.
The mediated oxidation of N-acetyl cysteine (NAC) and glutathione (GL) at the palladized aluminum electrode modified by Prussian blue film (PB/Pd–Al) is described. The catalytic activity of PB/Pd–Al was explored in terms of FeIII[FeIII(CN)6]/FeIII[FeII(CN)6]1− system by taking advantage of the metallic palladium layer inserted between PB film and Al, as an electron-transfer bridge. The best mediated oxidation of NAC and GL on the PB/Pd–Al electrode was achieved in 0.5 M KNO3 + 0.2 M potassium acetate of pH 2. The mechanism and kinetics of the catalytic oxidation reactions of the both compounds were monitored by cyclic voltammetry and chronoamperometry. The charge transfer-rate limiting step as well as overall oxidation reaction of NAC or GL is found to be a one-electron abstraction. The values of transfer coefficients α, catalytic rate constant k and diffusion coefficient D are 0.5, 3.2 × 102 M−1 s−1 and 2.45 × 10−5 cm2 s−1 for NAC and 0.5, 2.1 × 102 M−1 s−1 and 3.7 × 10−5 cm2 s−1 for GL, respectively. The modifying layers on the Pd–Al substrate have reproducible behavior and a high level of stability in the electrolyte solutions. The modified electrode is exploited for hydrodynamic amperometry of NAC and GL. The amperometric calibration graph is linear in concentration ranges 2 × 10−6–40 × 10−6 for NAC and 5 × 10−7–18 × 10−6 M for GL and the detection limits are 5.4 × 10−7 and 4.6 × 10−7 M, respectively.  相似文献   

17.
The voltammetric behavior of 4-methylbenzelidene camphor (MBC) was studied by square wave voltammetry (SWV) using mercury electrode. The experimental condition that provided the highest peak current with the best reduction signal definition of MBC was found in Britton-Robinson buffer and cationic surfactants, cetyltrimethylammoniun bromide (CTABr). A single peak of MBC reduction was observed at − 1.21 V versus Ag/AgCl. The developed methodology was applied for determination of MBC in commercial sunscreen SPF 15, 20 and 30 and for the simultaneous determination when other protection agents were associated, such as benzophenone-3 (BENZO) and octyl methoxycinammate (OMC). Both methodologies had shown good determination values for the analyzed samples. The calculated detection limit was 2.99 × 10− 9 mol L− 1 and the quantification limit was 9.98 × 10− 9 mol L− 1.  相似文献   

18.
Direct electrochemistry of glucose oxidase (GOx) has been achieved by its direct immobilization on carbon ionic liquid electrode (CILE) with a conductive hydrophobic ionic liquid, 1-butyl pyridinium hexafluophosphate ([BuPy][PF6]) as binder for the first time. A pair of reversible peaks is exhibited on GOx/CILE by cyclic voltammetry. The peak-to-peak potential separation (ΔEP) of immobilized GOx is 0.056 V in 0.067 M phosphate buffer solution (pH 6.98) with scan rate of 0.1 V/s. The average surface coverage and the apparent Michaelis–Menten constant are 6.69 × 10−11 mol·cm−2 and 2.47 μM. GOx/CILE shows excellent electrocatalytic activity towards glucose determination in the range of 0.1–800 μM with detection limit of 0.03 μM (S/N = 3). The biosensor has been successfully applied to the determination of glucose in human plasma with the average recoveries between 95.0% and 102.5% for three times determination. The direct electrochemistry of GOx on CILE is achieved without the help of any supporting film or any electron mediator. GOx/CILE is inexpensive, stable, repeatable and easy to be fabricated.  相似文献   

19.
Semiautomatic methods are described for the catalytic titrimetric determination of microamounts of silver and mercury(II) using a chloramine-T-selective electrode as monitor. The methods are based on the inhibitory effect of Ag(I) and Hg(II) on the iodide-catalyzed chloramine-T-arsenite and chloramine-T-H2O2 reactions. Microamounts of silver in the range 0.2–200 μg (1 × 10−7−1 × 10−4 M) and of mercury(II) in the range 0.1–200 μg (2.5 × 10−8−5 × 10−5 M) were determined using the chloramine-T-As(III) indicator reaction. Mercury(II) in the range 4–2000 μg (1 × 10−6−5 × 10−4 M) was also determined using the chloramine-T-H2O2 indicator reaction. The accuracy and precision were in the range 0.1–1%.  相似文献   

20.
A mesoporous TiO2 was synthesized according to the reported method, and then used to modify the carbon paste electrode (CPE). The electrochemical behavior of hypoxanthine was investigated with great detail. Compared with the unmodified CPE, the mesoporous TiO2-modified CPE greatly enhances the oxidation signal of hypoxanthine. Due to huge surface area, well-defined and special mesopores, the mesoporous TiO2-modified CPE shows considerable enhancement effect toward hypoxanthine. Based on this, a sensitive, rapid and convenient electrochemical method was developed for the determination of hypoxanthine. The linear range is over the range from 2.0 × 10−7 to 5.0 × 10−5 mol L−1, and the limit of detection is estimated to be 5.0 × 10−8 mol L−1. The relative standard deviation (RSD) for 10 mesoporous TiO2-modified CPEs is 5.7%. Finally, this sensing method was successfully used to determine hypoxanthine in human blood serum samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号