The present study investigated the effects of binaural spectral mismatch on binaural benefits in the context of bilateral cochlear implants using acoustic simulations. Binaural spectral mismatch was systematically manipulated by simulating changes in the relative insertion depths across ears. Sentence recognition, presented unilaterally and bilaterally, were measured in normal-hearing listeners in quiet and noise at +5 dB signal-to-noise ratio. Significant binaural benefits were observed when the interaural difference in insertion depth was 1 mm or less. This result suggests a dependence of the binaural benefit on redundant speech information, rather than on similarity in performance across ears.  相似文献   

2.
Tone languages differ from English in that the pitch pattern of a single-syllable word conveys lexical meaning. In the present study, dependence of tonal-speech perception on features of the stimulation was examined using an acoustic simulation of a CIS-type speech-processing strategy for cochlear prostheses. Contributions of spectral features of the speech signals were assessed by varying the number of filter bands, while contributions of temporal envelope features were assessed by varying the low-pass cutoff frequency used for extracting the amplitude envelopes. Ten normal-hearing native Mandarin Chinese speakers were tested. When the low-pass cutoff frequency was fixed at 512 Hz, consonant, vowel, and sentence recognition improved as a function of the number of channels and reached plateau at 4 to 6 channels. Subjective judgments of sound quality continued to improve as the number of channels increased to 12, the highest number tested. Tone recognition, i.e., recognition of the four Mandarin tone patterns, depended on both the number of channels and the low-pass cutoff frequency. The trade-off between the temporal and spectral cues for tone recognition indicates that temporal cues can compensate for diminished spectral cues for tone recognition and vice versa. An additional tone recognition experiment using syllables of equal duration showed a marked decrease in performance, indicating that duration cues contribute to tone recognition. A third experiment showed that recognition of processed FM patterns that mimic Mandarin tone patterns was poor when temporal envelope and duration cues were removed.  相似文献   

3.
Speech recognition was measured as a function of spectral resolution (number of spectral channels) and speech-to-noise ratio in normal-hearing (NH) and cochlear-implant (CI) listeners. Vowel, consonant, word, and sentence recognition were measured in five normal-hearing listeners, ten listeners with the Nucleus-22 cochlear implant, and nine listeners with the Advanced Bionics Clarion cochlear implant. Recognition was measured as a function of the number of spectral channels (noise bands or electrodes) at signal-to-noise ratios of + 15, + 10, +5, 0 dB, and in quiet. Performance with three different speech processing strategies (SPEAK, CIS, and SAS) was similar across all conditions, and improved as the number of electrodes increased (up to seven or eight) for all conditions. For all noise levels, vowel and consonant recognition with the SPEAK speech processor did not improve with more than seven electrodes, while for normal-hearing listeners, performance continued to increase up to at least 20 channels. Speech recognition on more difficult speech materials (word and sentence recognition) showed a marginally significant increase in Nucleus-22 listeners from seven to ten electrodes. The average implant score on all processing strategies was poorer than scores of NH listeners with similar processing. However, the best CI scores were similar to the normal-hearing scores for that condition (up to seven channels). CI listeners with the highest performance level increased in performance as the number of electrodes increased up to seven, while CI listeners with low levels of speech recognition did not increase in performance as the number of electrodes was increased beyond four. These results quantify the effect of number of spectral channels on speech recognition in noise and demonstrate that most CI subjects are not able to fully utilize the spectral information provided by the number of electrodes used in their implant.  相似文献   

4.
Chinese sentence recognition strongly relates to the reception of tonal information. For cochlear implant (CI) users with residual acoustic hearing, tonal information may be enhanced by restoring low-frequency acoustic cues in the nonimplanted ear. The present study investigated the contribution of low-frequency acoustic information to Chinese speech recognition in Mandarin-speaking normal-hearing subjects listening to acoustic simulations of bilaterally combined electric and acoustic hearing. Subjects listened to a 6-channel CI simulation in one ear and low-pass filtered speech in the other ear. Chinese tone, phoneme, and sentence recognition were measured in steady-state, speech-shaped noise, as a function of the cutoff frequency for low-pass filtered speech. Results showed that low-frequency acoustic information below 500 Hz contributed most strongly to tone recognition, while low-frequency acoustic information above 500 Hz contributed most strongly to phoneme recognition. For Chinese sentences, speech reception thresholds (SRTs) improved with increasing amounts of low-frequency acoustic information, and significantly improved when low-frequency acoustic information above 500 Hz was preserved. SRTs were not significantly affected by the degree of spectral overlap between the CI simulation and low-pass filtered speech. These results suggest that, for CI patients with residual acoustic hearing, preserving low-frequency acoustic information can improve Chinese speech recognition in noise.  相似文献   

5.
Understanding speech in background noise, talker identification, and vocal emotion recognition are challenging for cochlear implant (CI) users due to poor spectral resolution and limited pitch cues with the CI. Recent studies have shown that bimodal CI users, that is, those CI users who wear a hearing aid (HA) in their non-implanted ear, receive benefit for understanding speech both in quiet and in noise. This study compared the efficacy of talker-identification training in two groups of young normal-hearing adults, listening to either acoustic simulations of unilateral CI or bimodal (CI+HA) hearing. Training resulted in improved identification of talkers for both groups with better overall performance for simulated bimodal hearing. Generalization of learning to sentence and emotion recognition also was assessed in both subject groups. Sentence recognition in quiet and in noise improved for both groups, no matter if the talkers had been heard during training or not. Generalization to improvements in emotion recognition for two unfamiliar talkers also was noted for both groups with the simulated bimodal-hearing group showing better overall emotion-recognition performance. Improvements in sentence recognition were retained a month after training in both groups. These results have potential implications for aural rehabilitation of conventional and bimodal CI users.  相似文献   

6.
A series of three experiments used the method of magnitude estimation to examine binaural summation of the loudness of a 1000-Hz tone heard in the quiet and against various backgrounds of masking noise. In the quiet, binaural loudness as measured in sones, is twice monaural loudness. Two conditions of noise masking acted to increase the ratio of binaural/monaural loudness in sones above 2:1--that is, to produce supersummation. (1) When tone was presented to both ears, but masking noise to just one ear (dichotic stimulation), the loudness of the binaural tone was 30%-35% greater than the sum of the loudness of the monaural components. This increase in summation provides a suprathreshold analog to increases in threshold sensitivity observed with dichotic stimulation (masking-level differences). (2) Supersummation was also evident when tone and noise alike were presented to both ears (diotic stimulation); here, the binaural tone's loudness was 10%-25% greater than the sum of the monaural components. The increase in summation with diotic stimulation may be related to the characteristics of binaural summation of the noise masker itself.  相似文献   

7.
Frequency resolution was evaluated for two normal-hearing and seven hearing-impaired subjects with moderate, flat sensorineural hearing loss by measuring percent correct detection of a 2000-Hz tone as the width of a notch in band-reject noise increased. The level of the tone was fixed for each subject at a criterion performance level in broadband noise. Discrimination of synthetic speech syllables that differed in spectral content in the 2000-Hz region was evaluated as a function of the notch width in the same band-reject noise. Recognition of natural speech consonant/vowel syllables in quiet was also tested; results were analyzed for percent correct performance and relative information transmitted for voicing and place features. In the hearing-impaired subjects, frequency resolution at 2000 Hz was significantly correlated with the discrimination of synthetic speech information in the 2000-Hz region and was not related to the recognition of natural speech nonsense syllables unless (a) the speech stimuli contained the vowel /i/ rather than /a/, and (b) the score reflected information transmitted for place of articulation rather than percent correct.  相似文献   

8.
Tone recognition is important for speech understanding in tonal languages such as Mandarin Chinese. Cochlear implant patients are able to perceive some tonal information by using temporal cues such as periodicity-related amplitude fluctuations and similarities between the fundamental frequency (F0) contour and the amplitude envelope. The present study investigates whether modifying the amplitude envelope to better resemble the F0 contour can further improve tone recognition in multichannel cochlear implants. Chinese tone and vowel recognition were measured for six native Chinese normal-hearing subjects listening to a simulation of a four-channel cochlear implant speech processor with and without amplitude envelope enhancement. Two algorithms were proposed to modify the amplitude envelope to more closely resemble the F0 contour. In the first algorithm, the amplitude envelope as well as the modulation depth of periodicity fluctuations was adjusted for each spectral channel. In the second algorithm, the overall amplitude envelope was adjusted before multichannel speech processing, thus reducing any local distortions to the speech spectral envelope. The results showed that both algorithms significantly improved Chinese tone recognition. By adjusting the overall amplitude envelope to match the F0 contour before multichannel processing, vowel recognition was better preserved and less speech-processing computation was required. The results suggest that modifying the amplitude envelope to more closely resemble the F0 contour may be a useful approach toward improving Chinese-speaking cochlear implant patients' tone recognition.  相似文献   

9.
Four adult bilateral cochlear implant users, with good open-set sentence recognition, were tested with three different sound coding strategies for binaural speech unmasking and their ability to localize 100 and 500 Hz click trains in noise. Two of the strategies tested were envelope-based strategies that are clinically widely used. The third was a research strategy that additionally preserved fine-timing cues at low frequencies. Speech reception thresholds were determined in diotic noise for diotic and interaurally time-delayed speech using direct audio input to a bilateral research processor. Localization in noise was assessed in the free field. Overall results, for both speech and localization tests, were similar with all three strategies. None provided a binaural speech unmasking advantage due to the application of 700 micros interaural time delay to the speech signal, and localization results showed similar response patterns across strategies that were well accounted for by the use of broadband interaural level cues. The data from both experiments combined indicate that, in contrast to normal hearing, timing cues available from natural head-width delays do not offer binaural advantages with present methods of electrical stimulation, even when fine-timing cues are explicitly coded.  相似文献   

10.
Studies of speech perception in various types of background noise have shown that noise with linguistic content affects listeners differently than nonlinguistic noise [e.g., Simpson, S. A., and Cooke, M. (2005). "Consonant identification in N-talker babble is a nonmonotonic function of N," J. Acoust. Soc. Am. 118, 2775-2778; Sperry, J. L., Wiley, T. L., and Chial, M. R. (1997). "Word recognition performance in various background competitors," J. Am. Acad. Audiol. 8, 71-80] but few studies of multi-talker babble have employed background babble in languages other than the target speech language. To determine whether the adverse effect of background speech is due to the linguistic content or to the acoustic characteristics of the speech masker, this study assessed speech-in-noise recognition when the language of the background noise was either the same or different from the language of the target speech. Replicating previous findings, results showed poorer English sentence recognition by native English listeners in six-talker babble than in two-talker babble, regardless of the language of the babble. In addition, our results showed that in two-talker babble, native English listeners were more adversely affected by English babble than by Mandarin Chinese babble. These findings demonstrate informational masking on sentence-in-noise recognition in the form of "linguistic interference." Whether this interference is at the lexical, sublexical, and/or prosodic levels of linguistic structure and whether it is modulated by the phonetic similarity between the target and noise languages remains to be determined.  相似文献   

11.
Preliminary data [M. Epstein and M. Florentine, Ear. Hear. 30, 234-237 (2009)] obtained using speech stimuli from a visually present talker heard via loudspeakers in a sound-attenuating chamber indicate little difference in loudness when listening with one or two ears (i.e., significantly reduced binaural loudness summation, BLS), which is known as "binaural loudness constancy." These data challenge current understanding drawn from laboratory measurements that indicate a tone presented binaurally is louder than the same tone presented monaurally. Twelve normal listeners were presented recorded spondees, monaurally and binaurally across a wide range of levels via earphones and a loudspeaker with and without visual cues. Statistical analyses of binaural-to-monaural ratios of magnitude estimates indicate that the amount of BLS is significantly less for speech presented via a loudspeaker with visual cues than for stimuli with any other combination of test parameters (i.e., speech presented via earphones or a loudspeaker without visual cues, and speech presented via earphones with visual cues). These results indicate that the loudness of a visually present talker in daily environments is little affected by switching between binaural and monaural listening. This supports the phenomenon of binaural loudness constancy and underscores the importance of ecological validity in loudness research.  相似文献   

12.
This study evaluated the effects of time compression and expansion on sentence recognition by normal-hearing (NH) listeners and cochlear-implant (CI) recipients of the Nucleus-22 device. Sentence recognition was measured in five CI users using custom 4-channel continuous interleaved sampler (CIS) processors and five NH listeners using either 4-channel or 32-channel noise-band processors. For NH listeners, recognition was largely unaffected by time expansion, regardless of spectral resolution. However, recognition of time-compressed speech varied significantly with spectral resolution. When fine spectral resolution (32 channels) was available, speech recognition was unaffected even when the duration of sentences was shortened to 40% of their original length (equivalent to a mean duration of 40 ms/phoneme). However, a mean duration of 60 ms/phoneme was required to achieve the same level of recognition when only coarse spectral resolution (4 channels) was available. Recognition patterns were highly variable across CI listeners. The best CI listener performed as well as NH subjects listening to corresponding spectral conditions; however, three out of five CI listeners performed significantly poorer in recognizing time-compressed speech. Further investigation revealed that these three poorer-performing CI users also had more difficulty with simple temporal gap-detection tasks. The results indicate that limited spectral resolution reduces the ability to recognize time-compressed speech. Some CI listeners have more difficulty with time-compressed speech, as produced by rapid speakers, because of reduced spectral resolution and deficits in auditory temporal processing.  相似文献   

13.
Speech intelligibility and localization in a multi-source environment.   总被引:1,自引:0,他引:1  
Natural environments typically contain sound sources other than the source of interest that may interfere with the ability of listeners to extract information about the primary source. Studies of speech intelligibility and localization by normal-hearing listeners in the presence of competing speech are reported on in this work. One, two or three competing sentences [IEEE Trans. Audio Electroacoust. 17(3), 225-246 (1969)] were presented from various locations in the horizontal plane in several spatial configurations relative to a target sentence. Target and competing sentences were spoken by the same male talker and at the same level. All experiments were conducted both in an actual sound field and in a virtual sound field. In the virtual sound field, both binaural and monaural conditions were tested. In the speech intelligibility experiment, there were significant improvements in performance when the target and competing sentences were spatially separated. Performance was similar in the actual sound-field and virtual sound-field binaural listening conditions for speech intelligibility. Although most of these improvements are evident monaurally when using the better ear, binaural listening was necessary for large improvements in some situations. In the localization experiment, target source identification was measured in a seven-alternative absolute identification paradigm with the same competing sentence configurations as for the speech study. Performance in the localization experiment was significantly better in the actual sound-field than in the virtual sound-field binaural listening conditions. Under binaural conditions, localization performance was very good, even in the presence of three competing sentences. Under monaural conditions, performance was much worse. For the localization experiment, there was no significant effect of the number or configuration of the competing sentences tested. For these experiments, the performance in the speech intelligibility experiment was not limited by localization ability.  相似文献   

14.
It is generally accepted that the fusion of two speech signals presented dichotically is affected by the relative onset time. This study investigated the hypothesis that spectral resolution might be an additional factor influencing spectral fusion when the spectral information is split and presented dichotically to the two ears. To produce speech with varying degrees of spectral resolution, speech materials embedded in +5 dB S/N speech-shaped noise were processed through 6-12 channels and synthesized as a sum of sine waves. Two different methods of splitting the spectral information were investigated. In the first method, the odd-index channels were presented to one ear and the even-index channels to the other ear. In the second method the lower frequency channels were presented to one ear and the high-frequency channels to the other ear. Results indicated that spectral resolution did affect spectral fusion, and the effect differed across speech materials, with the sentences being affected the most. Sentences, processed through six or eight channels and presented dichotically in the low-high frequency condition were not fused as accurately as when presented monaurally. Sentences presented dichotically in the odd-even frequency condition were identified more accurately than when presented in the low-high condition.  相似文献   

15.
Spectral resolution has been reported to be closely related to vowel and consonant recognition in cochlear implant (CI) listeners. One measure of spectral resolution is spectral modulation threshold (SMT), which is defined as the smallest detectable spectral contrast in the spectral ripple stimulus. SMT may be determined by the activation pattern associated with electrical stimulation. In the present study, broad activation patterns were simulated using a multi-band vocoder to determine if similar impairments in speech understanding scores could be produced in normal-hearing listeners. Tokens were first decomposed into 15 logarithmically spaced bands and then re-synthesized by multiplying the envelope of each band by matched filtered noise. Various amounts of current spread were simulated by adjusting the drop-off of the noise spectrum away from the peak (40-5 dBoctave). The average SMT (0.25 and 0.5 cyclesoctave) increased from 6.3 to 22.5 dB, while average vowel identification scores dropped from 86% to 19% and consonant identification scores dropped from 93% to 59%. In each condition, the impairments in speech understanding were generally similar to those found in CI listeners with similar SMTs, suggesting that variability in spread of neural activation largely accounts for the variability in speech perception of CI listeners.  相似文献   

16.
Currently there are few standardized speech testing materials for Mandarin-speaking cochlear implant (CI) listeners. In this study, Mandarin speech perception (MSP) sentence test materials were developed and validated in normal-hearing subjects listening to acoustic simulations of CI processing. Percent distribution of vowels, consonants, and tones within each MSP sentence list was similar to that observed across commonly used Chinese characters. There was no significant difference in sentence recognition across sentence lists. Given the phonetic balancing within lists and the validation with spectrally degraded speech, the present MSP test materials may be useful for assessing speech performance of Mandarin-speaking CI listeners.  相似文献   

17.
The comparison of measured binaural performance with the better of two monaural measures (one from each ear) may lead to underestimated binaural benefit due to statistical sampling bias that favors the monaural condition. The mathematical basis of such bias is reviewed and applied to speech reception thresholds measured in 32 bilateral cochlear implant (CI) users for coincident and spatially separated speech and noise. It is shown that the bias increases with test-retest variation and is maximal for uncorrelated samples of identical underlying performance in each ear. When measured differences between ears were assumed to reflect actual underlying performance differences, the bias averaged across the CI users was about 0.2 dB for coincident target and noise, and 0.1 dB for spatially separated conditions. An upper-bound estimate of the bias, based on the assumption that both ears have the same underlying performance and observed differences were due to test-retest variation, was about 0.7 dB regardless of noise location. To the extent that the test-retest variation in these data is comparable to other studies, the results indicate that binaural benefits in bilateral cochlear implant users are not substantially underestimated (on for average) when binaural performance is compared with the better ear in each listening configuration.  相似文献   

18.
Nonlinear sensory and neural processing mechanisms have been exploited to enhance spectral contrast for improvement of speech understanding in noise. The "companding" algorithm employs both two-tone suppression and adaptive gain mechanisms to achieve spectral enhancement. This study implemented a 50-channel companding strategy and evaluated its efficiency as a front-end noise suppression technique in cochlear implants. The key parameters were identified and evaluated to optimize the companding performance. Both normal-hearing (NH) listeners and cochlear-implant (CI) users performed phoneme and sentence recognition tests in quiet and in steady-state speech-shaped noise. Data from the NH listeners showed that for noise conditions, the implemented strategy improved vowel perception but not consonant and sentence perception. However, the CI users showed significant improvements in both phoneme and sentence perception in noise. Maximum average improvement for vowel recognition was 21.3 percentage points (p<0.05) at 0 dB signal-to-noise ratio (SNR), followed by 17.7 percentage points (p<0.05) at 5 dB SNR for sentence recognition and 12.1 percentage points (p<0.05) at 5 dB SNR for consonant recognition. While the observed results could be attributed to the enhanced spectral contrast, it is likely that the corresponding temporal changes caused by companding also played a significant role and should be addressed by future studies.  相似文献   

19.
There is a tendency across languages to use a rising pitch contour to convey question intonation and a falling pitch contour to convey a statement. In a lexical tone language such as Mandarin Chinese, rising and falling pitch contours are also used to differentiate lexical meaning. How, then, does the multiplexing of the F(0) channel affect the perception of question and statement intonation in a lexical tone language? This study investigated the effects of lexical tones and focus on the perception of intonation in Mandarin Chinese. The results show that lexical tones and focus impact the perception of sentence intonation. Question intonation was easier for native speakers to identify on a sentence with a final falling tone and more difficult to identify on a sentence with a final rising tone, suggesting that tone identification intervenes in the mapping of F(0) contours to intonational categories and that tone and intonation interact at the phonological level. In contrast, there is no evidence that the interaction between focus and intonation goes beyond the psychoacoustic level. The results provide insights that will be useful for further research on tone and intonation interactions in both acoustic modeling studies and neurobiological studies.  相似文献   

20.
Speech recognition performance was measured in normal-hearing and cochlear-implant listeners with maskers consisting of either steady-state speech-spectrum-shaped noise or a competing sentence. Target sentences from a male talker were presented in the presence of one of three competing talkers (same male, different male, or female) or speech-spectrum-shaped noise generated from this talker at several target-to-masker ratios. For the normal-hearing listeners, target-masker combinations were processed through a noise-excited vocoder designed to simulate a cochlear implant. With unprocessed stimuli, a normal-hearing control group maintained high levels of intelligibility down to target-to-masker ratios as low as 0 dB and showed a release from masking, producing better performance with single-talker maskers than with steady-state noise. In contrast, no masking release was observed in either implant or normal-hearing subjects listening through an implant simulation. The performance of the simulation and implant groups did not improve when the single-talker masker was a different talker compared to the same talker as the target speech, as was found in the normal-hearing control. These results are interpreted as evidence for a significant role of informational masking and modulation interference in cochlear implant speech recognition with fluctuating maskers. This informational masking may originate from increased target-masker similarity when spectral resolution is reduced.  相似文献   