首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 359 毫秒
1.
Some of the polybrominated biphenyls (PBBs) found in the environment are axially chiral, due to hindered rotation about the interannular phenyl-phenyl bond. This applies for PBB congeners having two or more bromine substituents in ortho-position to this bond. In this study analytical methods were developed that allow determining the enantiomer fraction (EF) of axially chiral (atropisomeric) PBBs in environmental samples. A white-tailed sea eagle egg was used as test sample. The egg extract was purified and further fractionated by normal phase (NP) high performance liquid chromatography (HPLC), yielding enriched fractions of axially chiral PBB 132 and PBB 149. Gas chromatographic (GC) enantioseparation of the atropisomers of PBB 149 was achieved on one of nine tested modified cyclodextrin phases. Due to coelution with an unknown brominated compound, conventional GC/ECNI-MS, which is based on the detection of the bromide ion, did not allow for the establishment of the EF. However, by means of GC/EI-MS-MS it was possible to verify an EF of 0.42-0.43, i.e. a significant enantiomeric enrichment of the second eluting atropisomer of PBB 149 in the white-tailed sea eagle egg. This is the first proof of non-racemic proportions of a chiral PBB in environmental samples. Despite the testing of nine different chiral stationary phases, GC enantioseparation of PBB 132 or other atropisomeric PBB congeners failed. For this reason, an enantioselective reversed-phase HPLC method was developed. This method proved to be a powerful tool for the separation of PBB atropisomers. It was found that even a standard of the di-ortho substituted PBB 153 could be partially separated into atropisomers at 0 degrees C but already enantiomerized at 5 degrees C. For establishing the EF of PBB 132 in the bird egg sample a combination of enantioselective HPLC followed by non-chiral gas chromatography was employed. Using enantioselective HPLC, the atropisomers of PBB 132 were quantitatively targeted into two separate fractions at room temperature (20 degrees C). After addition of internal standards for volume adjustment the relative amounts of the atropisomers in the isolated fractions were quantified by using non-chiral GC/EI-MS analysis. A deviation from the racemic mixture of the atropisomers of PBB 132 in the egg extract could not be statistically proven.  相似文献   

2.
Enantioselective determination of the atropisomers of 2,2',3,4',5',6-hexabromobiphenyl (PBB 149) in a purified sample from a bird egg was attempted in this work. By application of the classic method for PBB determination, i.e. gas chromatography coupled to electron capture negative ionization mass spectrometry (GC/ECNI-MS) using the bromide ions, the enantiomers interfered with another brominated compound. Subsequent measurements clarified that this interference did not occur in the mass chromatogram of the molecular ion of PBB 149. Therefore, a GC/ECNI tandem mass spectrometry (MS/MS) method was developed, based on the fragmentation of [M]-. A suitable precursor-product ion transition was found for m/z 627.5 --> 80 +/- 1.5, representing the most abundant ion trace of the molecular ion and the bromide ions. Optimization of the ion source temperature, the methane gas pressure, and the collision voltages resulted in a robust method that could solve the problem. Subsequent injections of a technical PBB product (Firemaster BP-6) resulted in the anticipated racemic proportion (enantiomer fraction (EF) = 0.50 +/- 0.02 (n = 8)). By contrast, the EF in the purified extract of a bird egg was found to be 0.42 +/- 0.02 (n = 10), indicative of a significant enantioenrichment of the second eluting atropisomer. Additional measurements were performed on a non-chiral column. These measurements allowed for the detection of 16 hexabromobiphenyls (hexa-BBs) in Firemaster BP-6. These comparisons verified that PBB 149 enantiomers did not interfere with an isomer that could falsify the enantiomer fraction in the sample. The novel method using GC/ECNI-MS/MS in the selected reaction monitoring (SRM) mode was eight times more sensitive than application of conventional GC/ECNI-MS selected ion monitoring (SIM) analysis of the molecular ion.  相似文献   

3.
Pure enantiomers of chiral (atropisomeric) polychlorinated biphenyls (PCBs) obtained by high-performance liquid chromatography were used to establish the gas chromatographic elution sequences of the (+)- and (−)-enantiomers of six PCB atropisomers on Chirasil-Dex. The elution order was found to be (−/+) for PCBs 84, 132, 136, and 176 and (+/−) for PCBs 135 and 174. The retention characteristics of all 19 tri- and tetra-ortho atropisomeric PCBs were also investigated. Nine of the atropisomers could be separated using this chiral selector. PCBs 95, 132, and 149 were completely resovled and PCBs 84, 91, 135, 136, 174, and 176 were partially separated (R = 0.7–0.9). All of the separated congeners are 2,3,6-substituted in at least one ring, and conversely – none of the congeners that lacks 2,3,6-substitution could be separated. Thus, chiral recognition and enantiomer separation seems to be strongly governed by 2,3,6-substitution.  相似文献   

4.
气相色谱法测定多溴联苯的蒸气压   总被引:1,自引:0,他引:1  
采用气相色谱法,以二氯二苯三氯乙烷(DDT)为参考化合物,测定了6个多溴联苯(PBBs)在不同温度条件下的蒸气压, 然后使用Slide数理统计软件、以最小二乘法回归计算出Antoine方程的A,B,C参数,从而建立了6个PBBs的蒸气压与温度 的关联式。初步探讨了分子连接性指数与蒸气压的相关性,结果发现一阶拓扑指数与蒸气压表现出很好的线性关系,两者 的相关系数的平方大于0.99,标准偏差小于0.08。  相似文献   

5.
We report an efficient method for the preparation and purification of the Ih and the D5h isomers of Tm3N@C80. Following preparation in a Kratschmer-Huffman electric-arc generator, the Tm3N@C80 isomers were obtained by a chemical separation process followed by a one-stage isomer selective chromatographic high-performance liquid chromatography (HPLC) separation (pyrenyl, 5PYE column). The HPLC chromatographic retention behavior on a pentabromobenzyl (5PBB) column suggests a charge transfer of approximately 6 electrons; [M3N] 6+@C80(6-) and the chromatographic retention mechanisms of the Ih and the D5h isomers of Tm3N@C80 on both 5PBB and 5PYE columns are discussed. Single-crystal X-ray diffraction data demonstrate that the Tm3N cluster has a planar structure but represents a tight fit for trapping the Tm3N cluster inside the I h - and the D 5h -C 80 cages. Specifically, the Tm atoms punch out the cage carbon atoms adjacent to them. The "punched out" effect can be demonstrated by cage radii and pyramidal angles at cage carbon atoms near the Tm atoms. The magnetic susceptibility (chiT) for Tm3N@ Ih -C80 was found to exhibit Curie-Weiss behavior with C = 23.4 emu.K/mol, which is consistent with the calculated value for three uncoupled Tm3+ ions by considering the spin and orbital contributions with no quenching of the orbital angular momentum ( L = 5, S = 1, and J = 6; Ccalcd = 23.3 emu.K/mol). The electrochemical measurements demonstrate that both the Ih and the D5h isomers of Tm3N@C80 have a large electrochemical gap.  相似文献   

6.
A rapid and uncomplicated method for the fractionation of PCBs leading to an isolation of the highly toxic non-ortho substituted PCBs is described. The liquid chromatographic separation was achieved on a stationary phase consisting of activated carbon and Celite 545. Using eluents with different polarity, isolation of the non-ortho substituted PCBs in a single fraction was achieved. The fractions were analysed by GC/MS. The method was tested by the determination of non-ortho substituted PCBs in technical mixtures (Aroclor 1254 and Aroclor 1242). The results were compared with those obtained by using an HPLC fractionation on a porous graphitic carbon column. Finally, the micro-column fractionation was used for the determination of non-ortho substituted PCBs in native soil samples. Received: 5 March 1997 / Revised: 4 June 1997 / Accepted: 6 June 1997  相似文献   

7.
Polybrominated biphenyls (PBBs) have been used as flame-retardants mainly in the 1970s. Nowadays, they are found as ubiquitous contaminants in environmental samples. 2,2',4,4',5,5'-hexabromobiphenyl (PBB 153) is one of the persistent organic pollutants whose global ban is currently under discussion. Like the polychlorinated biphenyls (PCBs), 209 PBB congeners are existing in theory. However, only approximately 40 PBBs have been identified to date. In this work, we therefore used UV light, a sun simulator and natural sunlight for the photochemical debromination of PBB 209. All techniques led to the reductive debromination of PBB 209 albeit at different speed. Shifts of bromine substituents were not observed. Normal phase and reversed phase high performance liquid chromatography (HPLC) was used for the isolation of 12 reaction products some of which could be identified by (1)H NMR (PBB 202, 201, 197, 208, and 207). The other isolates (PBB 179, 178, 176, 199, 197, 196, and 194) were identified by realization of photolytic transformation studies with all isolates followed by comparison and evaluation of the obtained product spectra. In this way, we were able to establish (relative) retention times of the three nonabromobiphenyls, 9 of the 12 octabromobiphenyls, 14 of the 24 heptabromobiphenyl, and 16 of the 42 hexabromobiphenyls. Data on 24 PBBs are presented for the first time. Evaluation of the samples showed that Br was alternately removed from both phenyl rings and that positions with two vicinal Br substituents were most affected. Likewise, ortho-substituted PBBs were enriched.  相似文献   

8.
Enantioseparation and determination of selenomethionine enantiomers in selenized yeast was investigated using chiral separation techniques based on different principles, coupled on-line to inductively coupled plasma mass spectrometry (ICP-MS) for selenium-specific detection. High performance liquid chromatography (HPLC) on a beta-cyclodestrin (beta-CD) column, cyclodextrin-modified micellar electrokinetic chromatography (CD-MEKC), gas chromatography (GC) on a Chirasil-L-Val column, and HPLC on a Chirobiotic T column have been investigated as the chiral separation techniques. For HPLC separation on the beta-CD column, and also for CD-MEKC, selenomethionine enantiomers were derivatized with NDA/CN(-). For chiral separation by GC, selenomethionine enantiomers were converted into their N-trifluoroacetyl (TFA)-O-alkyl esters. The developed hybridation methodologies are compared with respect to enantioselectivity, sensitivity and analysis time. The usefulness of the best-suited method [HPLC (Chirobiotic T)-ICP-MS] was demonstrated by its application to the successful chiral speciation of selenium and D-and L-selenomethionine content determination in selenized yeast.  相似文献   

9.
A simple dual-column gas chromatographic system with a six-port switching valve has been used to separate the atropisomers of PCB congeners 84, 91, and 95 in technical PCB formulations and in extracts of soil and river sediment. A capillary column coated with a methylphenylsiloxane stationary phase (CP-Sil 8) was used as the first column, for retention window selection, and a permethylated β-cyclodextrin (ChirasilDex) capillary column as the main separation column. Because peak overlap could not be eliminated by optimization of column temperature, the enantiomeric ratios of PCB congeners could not be determined from the original chromatograms. The correct enantiomer ratio was determined from the peak areas obtained by deconvolution of the chromatograms. Whereas the PCB atropisomers considered were present in equal concentrations in the technical PCB formulations, analysis of a river sediment sample confirmed different residual concentrations of the atropisomers of congener 95.  相似文献   

10.
Two gas chromatography/mass spectrometry (GC/MS) methods for the determination of polybrominated biphenyls (PBBs) by isotope dilution analysis (IDA) using 13C12‐PBB 153 in the presence of polybrominated diphenyl ethers (PBDEs) were compared. Recovery of 13C12‐PBB 153 which was added to the extracted lipids before sample purification was commenced ranged from 88–117% (mean value 98.2 ± 8.9%). Nevertheless, IDA analysis of PBBs using 13C12‐labelled congeners is limited by the potential co‐elution of PBBs with polybrominated diphenyl ethers (PBDEs). The pair PBB 153 and BDE 154 was inspected since M+ and [M–2Br]+ ions of 13C12‐PBB 153 and BDE 154 were only separated by 4 u. Gas chromatography/electron ionization high‐resolution mass spectrometry with selected ion monitoring (GC/EI‐HRMS‐SIM) was suitable when m/z 475.7449 and m/z 477.7429 were used for 13C12‐PBB 153 because they are below the monoisotopic peak of the [M–2Br]+ fragment ion of hexaBDEs at m/z 479.7. Gas chromatography/electron capture negative ion tandem mass spectrometry selected reaction monitoring (GC/ECNI‐MS/MS‐SRM) measurements could be applied because 13C12‐PBB 153 and BDE 154 were separated by GC on a 25‐m Factor Four CP‐Sil 8MS column. Comparative measurements with GC/EI‐HRMS‐SIM and GC/ECNI‐MSMS‐SRM were carried out with samples of Tasmanian devils from Tasmania (Australia), an endangered species due to a virus epidemy which has already proved fatal for half of the population. Both techniques verified concentrations of PBB 153 in the range 0.3–11 ng/g lipids with excellent agreement of the levels in all but two samples. The PBB residue pattern demonstrated that PBB pollution originated from the previous discharge with technical hexabromobiphenyl which is dominated by PBB 153. Other congeners such as PBB 132 and PBB 138 were detected in the Tasmanian devils but the proportions relative to PBB 153 were lower than in the technical product. Samples of healthy and affected Tasmanian devils showed no significant difference in the PBB pollution level. The PBB concentrations in the Tasmanian devils were significantly below those causing toxic effects. On the other hand, PBB concentrations were one level or even higher than PBDEs. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

11.
A rapid and uncomplicated method for the fractionation of PCBs leading to an isolation of the highly toxic non-ortho substituted PCBs is described. The liquid chromatographic separation was achieved on a stationary phase consisting of activated carbon and Celite 545. Using eluents with different polarity, isolation of the non-ortho substituted PCBs in a single fraction was achieved. The fractions were analysed by GC/MS. The method was tested by the determination of non-ortho substituted PCBs in technical mixtures (Aroclor 1254 and Aroclor 1242). The results were compared with those obtained by using an HPLC fractionation on a porous graphitic carbon column. Finally, the micro-column fractionation was used for the determination of non-ortho substituted PCBs in native soil samples.  相似文献   

12.
Hexahalogenated 1,1′-dimethyl-2,2′-bipyrroles (HDBPs) are a group of marine halogenated natural products (HNPs) that have been detected in environmental samples from all over the world. The most frequently described congener is the 5,5′-dichloro-1,1′-dimethyl-3,3′,4,4′-tetrabromo-2,2′-bipyrrole (DBP-Br4Cl2, BC-10). This compound is axially chiral, by virtue of hindered rotation about the interannular pyrrole–pyrrole bond forming stable atropisomers. This effect was proven by the separation of synthesized racemic DBP-Br4Cl2 by enantioselective high performance liquid chromatography (HPLC). Pure enantiomers were isolated using enantioselective HPLC. Crystallization led to white crystals studied by X-ray analyses to determine the absolute configuration. Subsequent polarimetric measurements verified the first eluting enantiomer on HPLC as Ra-(+)-DBP-Br4Cl2 and the second as Sa-(−)-DBP-Br4Cl2. We also investigated the gas chromatography (GC) enantioseparation of DBP-Br4Cl2. However, too high temperatures in the injector port led to partial racemization at temperatures >150 °C. GC coupled to mass spectrometry was used to study DBP-Br4Cl2 in marine mammal samples. All samples contained both atropisomers of the natural product DBP-Br4Cl2 with enrichment of the levo (−) enantiomer. This led to the assumption that both enantiomers of DBP-Br4Cl2 were already produced in the environment.  相似文献   

13.
A gas chromatography–mass spectrometry (GC–MS) method was investigated for the simultaneous analysis of two types of endocrine disrupting compounds (EDCs), i.e., alkylphenol ethoxylates and brominated flame retardants (BFRs), by extraction and derivatization followed by GC–MS. Different solid phase extraction (SPE) cartridges (Cleanert PestiCarb, C18, Cleanert-SAX and Florosil), solvents (toluene, tetrahydrofuran, acetone, acetonitrile and ethyl acetate) and bases (NaHCO3, triethylamine and pyridine) were tested and the best chromatographic analysis was achieved by extraction with Strata-X (33?μm, Reverse Phase) cartridge and derivatization with heptafluorobutyric anhydride at 55?°C under Na2CO3 base in hexane. It was observed that APE together with lower substituted PBBs (PBB1, PBB10, PBB18 and PBB49), HBCD and TBBPA can be determined simultaneously under the same GC conditions. This simple and reliable analytical method was applied to determining trace amounts of these compounds from wastewater treatment plant samples. The recoveries of the target compounds from simulated water were above 60?%. The limit of detection ranged from 0.01 to 0.15?μg L?1 and the limit of quantification ranged from 0.05 to 0.66?μg L?1. There were no appreciable differences between filtered and unfiltered wastewater samples from Leeuwkil treatment plant although concentration of target analytes in filtered influent was slightly lower than the concentration of target analytes in unfiltered influent water. The concentrations of the target compounds from the wastewater treatment were determined from LOQ upwards.  相似文献   

14.
Recent achievements and anticipated future progress in high performance liquid chromatography of synthetic electroneutral polymers (polymer HPLC) are briefly reviewed. Basic retention mechanisms of polymer HPLC are explained and corresponding separation procedures are discussed. Advantages, drawbacks and pitfalls are presented of the most important polymer HPLC method, namely size exclusion chromatography. Principles of polymer HPLC methods combining various separation mechanisms within one chromatographic column (coupled procedures) or in a set of different chromatographic columns (two- and multi-dimensional procedures) are outlined.  相似文献   

15.

A gas chromatography–mass spectrometry (GC–MS) method was investigated for the simultaneous analysis of two types of endocrine disrupting compounds (EDCs), i.e., alkylphenol ethoxylates and brominated flame retardants (BFRs), by extraction and derivatization followed by GC–MS. Different solid phase extraction (SPE) cartridges (Cleanert PestiCarb, C18, Cleanert-SAX and Florosil), solvents (toluene, tetrahydrofuran, acetone, acetonitrile and ethyl acetate) and bases (NaHCO3, triethylamine and pyridine) were tested and the best chromatographic analysis was achieved by extraction with Strata-X (33 μm, Reverse Phase) cartridge and derivatization with heptafluorobutyric anhydride at 55 °C under Na2CO3 base in hexane. It was observed that APE together with lower substituted PBBs (PBB1, PBB10, PBB18 and PBB49), HBCD and TBBPA can be determined simultaneously under the same GC conditions. This simple and reliable analytical method was applied to determining trace amounts of these compounds from wastewater treatment plant samples. The recoveries of the target compounds from simulated water were above 60 %. The limit of detection ranged from 0.01 to 0.15 μg L−1 and the limit of quantification ranged from 0.05 to 0.66 μg L−1. There were no appreciable differences between filtered and unfiltered wastewater samples from Leeuwkil treatment plant although concentration of target analytes in filtered influent was slightly lower than the concentration of target analytes in unfiltered influent water. The concentrations of the target compounds from the wastewater treatment were determined from LOQ upwards.

  相似文献   

16.
Gas chromatographic separations of the stereoisomers of menthol derivatives, important intermediates in the synthesis of physiologically active natural products, were carried out on several substituted beta-cyclodextrin (CD) columns, including per-O-methyl-beta-cyclodextrin (PME-beta-CD), heptakis(2,3-di-O-acetyl-6-tert-butyldimethylsilyl)-beta-CD (DIAC-6-TBDS-beta-CD), and heptakis(2,3-di-O-methyl-6-tert-butyldimethylsilyl)-beta-CD (DIME-6-TBDS-beta-CD) as chiral stationary phases (CSPs). With the DIME-6-TBDS-beta-CD column, a separation of the Z- and E-isomers of methylidenementhol was accomplished; no separation was achieved with the other columns. The stereoisomers of methylidenementhol and the corresponding tert-butyldimethylsilyl (TBS) ether were separated on both the beta-CD and the heptakis(2,3,6-tri-O-methyl)-beta-cyclodextrin (TME-beta-CD) columns by high-performance liquid chromatography (HPLC) with a mobile phase involving acetonitrile and H(2)O. For the separation of the Z- and E-isomers of methylidenementhol, the TME-beta-CD column was superior. In contrast, the beta-CD column was preferable in the case of the corresponding TBS ether.  相似文献   

17.
采用Shim-Pack WCX-1型阳离子交换高压色谱柱对中国东亚钳蝎全蝎毒进行了分离,在鉴定了其中的抗癫痫肽、镇痛肽和抗肿瘤肽活性峰的基础上,应用Shim-Pack DIOL-300型凝胶排阻高压色谱柱对它们进行了进一步分离和鉴定,可以得到较纯的3种多肽。在高压色谱所提供的全蝎毒分离信息的基础上,应用与Shim-Pack WCX-1色谱柱具有相同交换基团的、具有较大吸附容量的CM Sepharose CL-6B软胶介质在低压色谱上对全蝎毒进行了分离,并分别对其中的抗癫痫肽、镇痛肽和抗肿瘤肽进行了鉴定。  相似文献   

18.
Aryl benzyl oximes having the configuration Z give rise to stereolabile atropisomers when a halogen atom is present in the ortho position of the aryl moiety, as a consequence of the restricted aryl-CN bond rotation. By means of dynamic (1)H NMR spectroscopy it has been possible to determine the corresponding rotation barrier, hence the lifetime of the atropisomers that, in the case of the iodine derivative, was found sufficiently long as to allow a physical separation to be achieved on an appropriately cooled enantioselective HPLC column. Comparison of the barriers determined by dynamic NMR and dynamic HPLC proved the equivalence of the two techniques. When the iodine atom was substituted by an alpha-naphthyl group, two dynamic processes were observed. That with the lower barrier could be determined by NMR and that with the higher barrier by HPLC, thus outlining the complementarity of these two techniques.  相似文献   

19.
李芳  李佳杨  张华燕  郭兴杰 《色谱》2008,26(6):766-768
采用直链淀粉手性固定相高效液相色谱法在正相条件下直接拆分了比索洛尔对映异构体。分别以异丙醇、乙醇为有机改性剂,考察了流动相的组成与配比、流速及柱温等因素对比索洛尔对映体分离的影响。确定了比索洛尔对映体的最佳拆分条件:流动相正己烷-乙醇-二乙胺(体积比为88∶12∶0.1),流速0.6 mL/min,检测波长270 nm,柱温20 ℃。该方法可快捷、简便地拆分比索洛尔对映体。  相似文献   

20.
18-Crown-6 tetracarboxylic acid (18C6H4) has been successfully used as a chiral selector for capillary electrophoretic (CE), high-performance liquid chromatographic (HPLC), and gas chromatographic (GC) separation of the enantiomers of DL-amino compounds. We have previously used X-ray crystallographic analysis and HPLC with an immobilized 18C6H4 chiral stationary phase to study chiral recognition by 18C6H4 of several DL amino acids (DL-AA). In this study CE was used for chiral recognition of several DL-AA in electrolyte solution containing 18C6H4, in which the analyte (D or L amino acid) interacts freely. Among 14 DL-AA investigated, the enantiomers of nine (Glu, Ile, Met, PheG, Phe, Ser, Tyr, Val, and Thr) were successfully recognized in 4-15 mM 18C6H4. Indirect photometric detection with a cationic dye, chrysoidine, was used to monitor non-chromophoric DL-AA. Among nine successfully recognized DL-AA, the D forms of Ser, Thr and Met migrated faster than the corresponding L forms. The strengths of interactions predicted from the order of migration of each enantiomer in CE were different from those in HPLC analysis. The different enantiomer recognition probably can be ascribed to the difference between CE in which the selector is not immobilized and HPLC in which the selector is immobilized by means of a spacer.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号