An anodic stripping voltammetric procedure for the determination of Cu(II) at an in situ-plated stannum film electrode (SnFE) was described. The results indicated that the SnFE had an attractive electroanalytical performance, with two distinct voltammetric stripping signals for copper and stannum, and showed the superior advantage for the determination of copper compared with the bismuth film electrode. Several experimental parameters were optimized. The SnFE exhibited highly linear behavior in the concentration range from 1.0 to 100.0 μg L−1 of Cu(II) (r = 0.994) with the detection limit of 0.61 μg L−1 (S/N = 3), and the relative standard deviation for a solution containing 40.0 μg L−1 Cu(II) was 2.2% (n = 8). The procedure has been successfully applied for the determination of Cu(II) in lake water sample.  相似文献   

2.
The development of a direct competitive enzyme-linked immunosorbent assay based on polyclonal antibodies for N-methylcarbamate insecticide metolcarb is described. Two new haptens for the metolcarb were designed and synthesized. Both haptens were conjugated with keyhole limpet hemocyanin to form the immunogens. Four rabbits were immunized with the immunogens for production of polyclonal antibodies against metolcarb. Antisera titers were tested on the homologous coating antigens using a noncompetitive indirect enzyme-linked immunosorbent assay. The high titer antisera were used to develop the direct competitive enzyme-linked immunosorbent assay for the detection of metolcarb. The antibody–antigen combination with the highest selectivity for metolcarb was further optimized and its tolerance to changes in chemical conditions (ionic strength, pH value, and organic solvent) was studied. Under optimum conditions, the sensitivity and the limit of detection were determined to be 22 μg L−1 and 1.2 μg L−1 respectively. Determination of metolcarb in fruit juices and vegetables was accomplished by simple, rapid, and efficient extraction methods. Recoveries of metolcarb from spiked samples ranged from 80.5% to 109.5%. Validation of the developed immunosorbent assay was conducted by comparison of results from high-performance liquid chromatography. The correlation between the data obtained using developed immunosorbent assay and high-performance liquid chromatography was high (R 2 = 0.9884). Therefore, the developed immunosorbent assay in this study was suitable for the rapid quantitative determination of metolcarb in agricultural products.  相似文献   

3.
The development and characterization of one rat monoclonal antibody (mAb) for 2,4-dinitroaniline and of two rat mAbs for 2,6-dinitroaniline are described. With the immunization of rats with 2,4,6-trinitrophenyl-glycylglycine–keyhole limpet hemocyanine (KLH) conjugate one mAb (PK 5H6) has been developed and formatted into a competitive enzyme-linked immunosorbent assay (ELISA). This assay no. 1 is very sensitive for 2,4-dinitroaniline with a test midpoint of 0.24 ± 0.06 μg L−1 (n = 19) in 40 mM phosphate-buffered saline (PBS). A second hapten, 3-(4-amino-2,6-dinitrophenyl)propionic acid, which was also conjugated to KLH and used for the immunization of rats, led to two sensitive ELISAs for 2,6-dinitroaniline in 40 mM PBS with test midpoints of 0.61 ± 0.08 μg L−1 (n = 15; mAb DNT4 3C6; assay no. 2) and 0.94 ± 0.29 μg L−1 (n = 17; mAb DNT4 1A7, assay no. 3). Selectivities of all mAbs were checked with more than 20 compounds, including nitroaromatic compounds, 2,6-dinitroaniline pesticides, and other substituted derivatives of aniline. As very noticeable cross-reactivities, all mAbs recognize 2-chloro-4,6-dinitroaniline, 4-chloro-2,6-dinitroaniline and 2-bromo-4,6-dinitroaniline, the last of these being a major metabolite of the azo dye Disperse Blue 79. As first demonstrations of applications, two ELISAs (assays no. 1 and 2) were used for the analysis of 2,4- or 2,6-dinitroaniline in spiked water and soil samples. Recovery data were determined and the majority of these data were in the range of 90–120%. These assays can contribute to a very cost-effective and environmentally friendly immunochemical surveillance monitoring of environmental samples for contaminations with these compounds. To the best of the authors’ knowledge, these are the first antibodies described for 2,4-dinitroaniline and for 2,6-dinitroaniline.  相似文献   

4.
Benzene is classified as a Group I carcinogen by the International Agency for Research on Cancer (IARC). The risk assessment for benzene can be performed by monitoring environmental and occupational air, as well as biological monitoring through biomarkers. The present work developed and validated methods for benzene analysis by GC/MS using SPME as the sampling technique for ambient air and breath. The results of the analysis of air in parks and avenues demonstrated a significant difference, with average values of 4.05 and 18.26 μg m−3, respectively, for benzene. Sampling of air in the occupational environment furnished an average of 3.41 and 39.81 μg m−3. Moreover, the correlations between ambient air and expired air showed a significant tendency to linearity (R 2 = 0.850 and R 2 = 0.879). The results obtained for two groups of employees (31.91 and 72.62 μg m−3) presented the same trend as that from the analysis of environmental air.  相似文献   

5.
A sensitive and effective method for simultaneous determination of triazolopyrimidine sulfonamide herbicide residues in soil, water, and wheat was developed using ultra-performance liquid chromatography coupled with tandem mass spectrometry. The four herbicides (pyroxsulam, flumetsulam, metosulam, and diclosulam) were cleaned up with an off-line C18 SPE cartridge and detected by tandem mass spectrometry using an electrospray ionization source in positive mode (ESI+). The determination of the target compounds was achieved in <2.0 min. The limits of detection were below 1 μg kg−1, while the limits of quantification did not exceed 3 μg kg−1 in different matrices. Quantitation was determined from calibration curves of standards containing 0.05–100 μg L−1 with r 2 > 0.997. Recovery studies were conducted at three spiked levels (0.2, 1, and 5 μg kg−1 for water; 5, 10, and 100 μg kg−1 for soil and wheat). The overall average recoveries for this method in water, soil, wheat plants, and seeds at three levels ranged from 75.4% to 106.0%, with relative standard deviations in the range of 2.1–12.5% (n = 5) for all analytes.  相似文献   

6.
A mid-infrared enzymatic assay for label-free monitoring of the enzymatic reaction of fructose-1,6-bisphosphatase with fructose 1,6-bisphosphate has been proposed. The whole procedure was done in an automated way operating in the stopped flow mode by incorporating a temperature-controlled flow cell in a sequential injection manifold. Fourier transform infrared difference spectra were evaluated for kinetic parameters, like the Michaelis–Menten constant (K M) of the enzyme and V max of the reaction. The obtained K M of the reaction was 14 ± 3 g L−1 (41 μM). Furthermore, inhibition by adenosine 5′-monophosphate (AMP) was evaluated, and the K MApp value was determined to be 12 ± 2 g L−1 (35 μM) for 7.5 and 15 μM AMP, respectively, with V max decreasing from 0.1 ± 0.03 to 0.05 ± 0.01 g L−1 min−1. Therefore, AMP exerted a non-competitive inhibition.  相似文献   

7.
A rapid and simple miniaturized liquid–liquid extraction method has been developed for the determination of topramezone in soil, corn, wheat, and water samples using ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-electrospray ionization (ESI)/MS/MS). The established method for the extraction and purification procedure was based on liquid–liquid partitioning into an aqueous solution at a low pH (pH ≈ 2.5), followed by back-partitioning into water at pH > 9. Two precursor, product ion transitions for topramezone were measured and evaluated to provide the maximum degree of confidence in the results. Under negative ESI conditions, quantitation was achieved by monitoring the fragment at m/z = 334 and the qualitative fragment at m/z = 318, whereas also collecting the corresponding parent ion at m/z = 362. Chromatographic separation was achieved using gradient elution with a mobile phase consisting of methanol and a 0.01% aqueous ammonium hydroxide solution. Recovery studies for soil, corn, wheat, and water were conducted at four different topramezone concentrations (5 or 10, 50, 100, and 1,000 μg kg−1); the overall average recoveries ranged from 79.9% to 98.4% with intra-day relative standard deviations (RSD) of 3.1~8.7% and inter-day RSD of 4.3~7.5%. Quantitative results were determined from calibration curves of topramezone standards containing 1–500 μg L−1 with an R 2 ≥ 0.9994. Method sensitivities expressed as limits of quantitation were typically 6, 8, 9, and 1 μg kg−1 in soil, corn, wheat, and water, respectively. The results of the method validation confirmed that this proposed method was convenient and reliable for the determination of topramezone residues in soil, corn, wheat, and water.  相似文献   

8.
A simple and efficient method, based on ultrasound-enhanced surfactant-assisted dispersive liquid–liquid microextraction (UESA-DLLME) followed by high-performance liquid chromatography (HPLC) has been developed for extraction and determination of ketoconazole and econazole nitrate in human blood samples. In this method, a common cationic surfactant, cetyltrimethylammonium bromide (CTAB), was used as dispersant. Chloroform (40 μL) as extraction solvent was added rapidly to 5 mL blood containing 0.068 mg mL−1 CTAB. The mixture was then sonicated for 2 min to disperse the organic chloroform phase. After the extraction procedure, the mixture was centrifuged to sediment the organic chloroform phase, which was collected for HPLC analysis. Several conditions, including type and volume of extraction solvent, type and concentration of the surfactant, ultrasound time, extraction temperature, pH, and ionic strength were studied and optimized. Under the optimum conditions, linear calibration curves were obtained in the ranges 4–5000 μg L−1 for ketoconazole and 8–5000 μg L−1 for econazole nitrate, with linear correlation coefficients for both >0.99. The limits of detection (LODs, S/N = 3) and enrichment factors (EFs) were 1.1 and 2.3 μg L−1, and 129 and 140 for ketoconazole and econazole nitrate, respectively. Reproducibility and recovery were good. The method was successfully applied to the determination of ketoconazole and econazole nitrate in human blood samples.  相似文献   

9.
Experimental work performed was aimed at the assessment of a competitive capillary electrophoresis immunoassay with laser-induced fluorescence (CEIA-LIF) detection for the determination of the Cry1Ab endotoxin from Bacillus thuringensis. The binding constant of a monoclonal antibody, raised against the insecticide protein Cry1Ab, was determined on a microplate by indirect enzyme-linked immunosorbent assay (ELISA) and compared with that obtained in-capillary under nonequilibrium separation conditions. The two binding constants appear comparable—(5.0 ± 1.2) × 106 M−1 and (9.06 ± 5.7) × 106 M−1—reflecting good preservation of the antibody binding behavior in the capillary electrophoresis format. These results allow use of a calibration curve possible between 0.2 and 150 nM of endotoxin protein, with a limit of detection of 0.5 nM (33 μg L−1). Preliminary recovery experiments on maize extracts spiked with known amounts of Cry1Ab endotoxin also showed promising results in detecting the toxin in complex real matrices.  相似文献   

10.
This work presents a comparison of convective interaction media (CIM) and controlled pore glass (CPG) as solid supports for immunoglobulin antibodies used in bioanalytical detection of allergens in foodstuffs. A flow-injection manifold with highly sensitive thermal lens spectrometric detection was used for this purpose. Using beta-lactoglobulin, a milk allergen, as a model analyte, CIM disc supports had a higher linear range (0.2–3.5 μg L−1), better reproducibility (intra-day RSD = 1%, inter-day RSD = 10%), lower consumption of reagents, and better immunocolumn stability (1 month, over 240 injections of substrate), while providing comparable LODs (0.1 μg L−1). Application of CIM discs as solid supports in immunocolumns for allergen detection enables fast and sensitive screening of allergens in foodstuffs with sample throughput of up to eight samples per hour.  相似文献   

11.
In this study, a panel of haptens was synthesized for immunoconjugate preparation, and several haptens for heterologous tracer conjugates were also prepared. A highly sensitive polyclonal antibody against the organophosphorus insecticide phosmet was obtained and competitive direct enzyme-linked immunosorbent assays (cd-ELISA) for this pesticide were developed. In the cd-ELISA, the limit of detection (IC15) was 0.6 μg kg−1 and the sensitivity (IC50) was 20 μg kg−1. The suitability of the ELISA for pesticide quantification in peach, apple, orange juice, and apple juice was also studied. Good accuracy and precision were obtained with mean recoveries between 78% and 102.3% and mean coefficients of variation below 13.63%. Validation of the ELISA was conducted by high-performance liquid chromatography. The correlation between the data obtained using the microwell assay and the high-performance liquid chromatography was good (R 2 = 0.9849). The developed immunoassay methods were suitable for the rapid quantitative or qualitative determination of phosmet in food samples.  相似文献   

12.
A fast and sensitive liquid chromatography–mass spectrometry method was developed for the determination of ursolic acid (UA) in rat plasma and tissues. Glycyrrhetinic acid was used as the internal standard (IS). Chromatographic separation was performed on a 3.5 μm Zorbax SB-C18 column (30 mm × 2.1 mm) with a mobile phase consisting of methanol and aqueous 10 mM ammonium acetate using gradient elution. Quantification was performed by selected ion monitoring with (m/z) 455 for UA and (m/z) 469 for the IS. The method was validated in the concentration range of 2.5 − 1470 ng mL−1 for plasma samples and 20 − 11760 ng g−1 for tissue homogenates. The intra- and inter-day assay of precision in plasma and tissues ranged from 1.6% to 7.1% and 3.7% to 9.0%, respectively, and the intra- and inter-day assay accuracy was 84.2 − 106.9% and 82.1 − 108.1%, respectively. Recoveries in plasma and tissues ranged from 83.2% to 106.2%. The limits of detections were 0.5 ng mL−1 or 4.0 ng g−1. The recoveries for all samples were >90%, except for liver, which indicated that ursolic acid may metabolize in liver. The main pharmacokinetic parameters obtained were T max = 0.42 ± 0.11 h, C max = 1.10 ± 0.31 μg mL−1, AUC = 1.45 ± 0.21 μg h mL−1 and K a = 5.64 ± 1.89 h−1. The concentrations of UA in rat lung, spleen, liver, heart, and cerebellum were studied for the first time. This method is validated and could be applicable to the investigation of the pharmacokinetics and tissue distribution of UA in rats.  相似文献   

13.
A piezoelectric quartz crystal (PQC) sensor based on a molecularly imprinted polymer (MIP) has been developed for enantioselective and quantitative analysis of d-(+)-methamphetamine (d(+)-MA). The sensor was produced by bulk polymerization and the resulting MIP was then coated on the gold electrode of an AT-cut quartz crystal. Conditions such as volume of polymer coating, curing time, type of PQC, baseline solvent, pH, and buffer type were found to affect the sensor response and were therefore optimized. The PQC-MIP gave a stable response to different concentrations of d(+)-MA standard solutions (response time = 10 to 100 s) with good repeatability (RSD = 0.03 to 3.09%; n = 3), good reproducibility (RSD = 3.55%; n = 5), and good reversibility (RSD = 0.36%; n = 3). The linear range of the sensor covered five orders of magnitude of analyte concentration, ranging from 10−5 to 10−1 μg mL−1, and the limit of detection was calculated as 11.9 pg d(+)-MA mL−1 . The sensor had a highly enantioselective response to d(+)-MA compared with its response to l(−)-MA, racemic MA, and phentermine. The developed sensor was validated by applying it to human urine samples from drug-free individuals spiked with standard d(+)-MA and from a confirmed MA user. Use of the standard addition method (SAM) and samples spiked with d(+)-MA at levels ranging from 1 × 10−3 to 1 × 10−2 μg mL−1 showed recovery was good (95.3 to 110.9%).  相似文献   

14.
Specific polyclonal antibodies against s-triazine herbicides were obtained by preparing immunogens coupling home-synthesized haptens derivatives of simazine (6-chloro-N-ethyl-N′-ethyl-1,3,5-triazine-2,4-diamine) to lysine groups of hemocyanin from keyhole limpets and bovine serum albumin carrier proteins. Three highly sensitive rabbit antisera were obtained and evaluated with a battery of six enzyme tracers derived from triazine structures in an optimized ELISA format. The antiserum As8 and the HRP-2f tracer, which yield the best assay sensitivity for simazine (detection limit 0.11 ± 0.02 μg L−1, IC50 0.88 ± 0.04 μg L−1), were applied to the development of a sensitive flow-through immunoassay for the analysis of this herbicide. The automated assay was based on a direct competitive immunosorbent assay and fluorescence detection. The optimized method presents an IC50 value of 0.35 ± 0.04 μg L−1 with a detection limit of 1.3 ± 0.9 ng L−1 and a dynamic range from 0.010 to 7.5 μg L−1 simazine. The generic nature of the antiserum was shown by good relative cross-reactivities with other triazines such as atrazine (420%) or propazine (130%) and a lower response to terbutylazine (6.4%) and desethyl-atrazine (2.2%). No cross-reactivity was obtained for nonrelated pesticides such as 2,4-dichlorophenoxyacetic acid or linuron and the assay could be applied as a screening method for triazine herbicides. The total analysis time was 30 min per determination and the immunosensor could be reused for more than 150 cycles without significant loss of activity. The immunosensor has been successfully applied to the direct analysis of simazine in surface water samples at the nanogram per liter level. The results obtained by comparative analysis of the immunosensor with a chromatographic procedure for triazines showed a close correspondence.  相似文献   

15.
There is a lack of fundamental knowledge about the scale up of biosurfactant production. In order to develop suitable technology of commercialization, carrying out tests in shake flasks and bioreactors was essential. A reactor with integrated foam collector was designed for biosurfactant production using Bacillus subtilis isolated from agricultural soil. The yield of biosurfactant on biomass (Y p/x), biosurfactant on sucrose (Y p/s), and the volumetric production rate (Y) for shake flask were obtained about 0.45 g g−1, 0.18 g g−1, and 0.03 g l−1 h−1, respectively. The best condition for bioreactor was 300 rpm and 1.5 vvm, giving Y x/s, Y p/x, Y p/s, and Y of 0.42 g g−1, 0.595 g g−1, 0.25 g g−1, and 0.057 g l−1 h−1, respectively. The biosurfactant maximum production, 2.5 g l−1, was reached in 44 h of growth, which was 28% better than the shake flask. The obtained volumetric oxygen transfer coefficient (K L a) values at optimum conditions in the shake flask and the bioreactor were found to be around 0.01 and 0.0117 s−1, respectively. Comparison of K L a values at optimum conditions shows that biosurfactant production scaling up from shake flask to bioreactor can be done with K L a as scale up criterion very accurately. Nearly 8% of original oil in place was recovered using this biosurfactant after water flooding in the sand pack.  相似文献   

16.
A novel, simple, and rapid reversed-phase liquid chromatography–tandem mass spectrometric methodology was developed for the analysis of natamycin in wine samples. Natamycin was protonated to form singly charged ions in an electrospray positive ion mode. Data acquisition under MS/MS was achieved by applying multiple reaction monitoring (MRM) of three fragment ion transitions (666.3 → 648.2, 666.3 → 503.3, and 666.3 → 485.2) to provide a high degree of sensitivity and specificity. Chromatographic separation was performed on a rapid resolution column using a mobile phase consisting of an acetonitrile/water mixture with a total run time of 5.0 min. After only filtration as pretreatment, the sample was injected into the chromatographic system. The proposed method was validated in terms of selectivity, trueness, precision, decision limit (CCα), and detection capability (CCβ) according to 2002/657/EC Commission decision. The values for trueness, reported as bias (%), agreed with those established by the aforementioned document. Repeatability (intraday variability) values were 12.37% at a concentration of 1.0 μg L−1 and 8.99–4.19% at concentrations between 2.5 and 10 μg L−1. The overall within-laboratory (interday variability) reproducibility was 15.47% at a concentration of 1.0 μg L−1, which was significantly lower than the indicative value reported in the EU decision. The results indicated that the proposed approach is a sensitive, fast, reproducible, and robust methodology suitable for the analysis of natamycin levels in wine samples.  相似文献   

17.
The purpose of this study was the development and validation of an LC–MS–MS method for simultaneous analysis of ibuprofen (IBP), 2-hydroxyibuprofen (2-OH-IBP) enantiomers, and carboxyibuprofen (COOH-IBP) stereoisomers in fungi culture medium, to investigate the ability of some endophytic fungi to biotransform the chiral drug IBP into its metabolites. Resolution of IBP and the stereoisomers of its main metabolites was achieved by use of a Chiralpak AS-H column (150 × 4.6 mm, 5 μm particle size), column temperature 8 °C, and the mobile phase hexane–isopropanol–trifluoroacetic acid (95: 5: 0.1, v/v) at a flow rate of 1.2 mL min−1. Post-column infusion with 10 mmol L−1 ammonium acetate in methanol at a flow rate of 0.3 mL min−1 was performed to enhance MS detection (positive electrospray ionization). Liquid–liquid extraction was used for sample preparation with hexane–ethyl acetate (1:1, v/v) as extraction solvent. Linearity was obtained in the range 0.1–20 μg mL−1 for IBP, 0.05–7.5 μg mL−1 for each 2-OH-IBP enantiomer, and 0.025–5.0 μg mL−1 for each COOH-IBP stereoisomer (r ≥ 0.99). The coefficients of variation and relative errors obtained in precision and accuracy studies (within-day and between-day) were below 15%. The stability studies showed that the samples were stable (p > 0.05) during freeze and thaw cycles, short-term exposure to room temperature, storage at −20 °C, and biotransformation conditions. Among the six fungi studied, only the strains Nigrospora sphaerica (SS67) and Chaetomium globosum (VR10) biotransformed IBP enantioselectively, with greater formation of the metabolite (+)-(S)-2-OH-IBP. Formation of the COOH-IBP stereoisomers, which involves hydroxylation at C3 and further oxidation to form the carboxyl group, was not observed.  相似文献   

18.
Nickel(II) and lead(II) ionic imprinted 8-hydroxyquinoline polymers were synthesized by a precipitation polymerization technique and were used as selective solid phase extraction supports for the determination of nickel and lead in seawater by flow injection solid phase extraction on-line inductively coupled plasma-optical emission spectrometry. An optimum loading flow rate of 2.25 mL min−1 for 2 min and an elution flow rate of 2.25 mL min−1 for 1 min gave an enrichment factor of 15 for nickel. However, a low dynamic capacity and/or rate for adsorption and desorption was found for lead ionic imprinted polymer and a flow rate of 3.00 mL min−1 for 4-min loading and a flow rate of 2.25 mL min−1 for 1-min elution gave a enrichment factor of 5. The limit of detection was 0.33 μg L−1 for nickel and 1.88 μg L−1 for lead, with a precision (n = 11) of 8% (2.37 μg Ni L−1) for nickel and 11% (8.38 μg Pb L−1) for lead. Accuracy was also assessed by analyzing SLEW-3 (estuarine water) and TM-24 (lake water) certified reference materials, and the values determined were in good agreement with the certified concentrations.  相似文献   

19.
A novel molecularly imprinted polymer (MIP) for the separation and concentration of ractopamine (RAC) was prepared by a covalent imprinting approach and the template was removed successfully by hydrolysis, so that four carboxylic acid groups were left in the cavities and could specifically rebind RAC through noncovalent interaction: hydrogen bonding. The conditions for synthesis of the MIP were optimized during the polymerization process, and a molar ratio of template–functional monomer complexes to cross-linker of 1:3 was confirmed. The adsorption capacity of the MIP was 4.1-fold that of the nonimprinted polymer, and the adsorption reaction reached equilibrium after 25 min at 50 mg L-1 concentration. The results of the competitive adsorption test showed that the MIPs had specific recognition ability for the analyte RAC. In addition, the important factors affecting the efficiency of the method which was developed using the MIPs as a solid-phase sorbent for separation and determination of RAC combined with high-performance liquid chromatography with fluorescence detection were optimized. Under the optimum experimental conditions, the linear range of the calibration curve in the method was 0.05-5 μg L-1 (R 2 = 0.98) and the limit of detection (signal-to-noise ratio of 3) was 0.01 μg L-1. The proposed method was applied to determination of RAC in spiked feedstuffs and urine samples, with recoveries ranging from 74.17 to 114.46% and relative standard deviation (n = 3) below 4.55 in all cases.  相似文献   

20.
A novel and environmentally friendly microextraction method, termed ionic liquid dispersive liquid-phase microextraction (IL-DLPME), has been developed for rapid enrichment of triclosan and triclocarban before analysis by high-performance liquid phase chromatography–electrospray tandem mass spectrometry (HPLC–ESI-MS–MS). Instead of using toxic organic solvents, an ionic liquid was used as a green extraction solvent. This also avoided the instability of the suspending drop in single-drop liquid-phase microextraction, and the heating and cooling step in temperature-controlled ionic liquid dispersive liquid phase microextraction. Factors that may affect the enrichment efficiency, for example volume of ionic liquid, type and volume of dispersive solvent, pH, extraction time, and NaCl content were investigated in detail and optimized. Under optimum conditions, linearity of the method was observed over the range 0.2–12 μg L−1 for triclocarban and 1–60 μg L−1 for triclosan with correlation coefficients ranging from 0.9980 to 0.9990, respectively. The sensitivity of the proposed method was found to be excellent, with limits of detection in the range 0.040–0.58 μg L−1 and precision in the range 7.0–8.8% (RSD, n = 5). This method has been successfully used to analyze real environmental water samples and satisfactory results were achieved. Average recoveries of spiked compounds were in the range 70.0–103.5%. All these results indicated that the developed method would be a green method for rapid determination of triclosan and triclocarban at trace levels in environmental water samples.  相似文献   