1.
The total current and selected ion currents from the electrospray ionization (ES1) of 10?5 M solutions of cocaine hydrochloride and deoxycytidine monophosphate (dCMP) monosodium salt in methanol and water solvents were compared in positive and negative ion modes, respectively, without and with SF6, gas as a discharge suppressant. The ESI onset voltages (Von), were the same for the positive and negative ion modes. The Von, for methanol was much lower than that for water and in agreement with the equation of D. P. H. Smith, who attributes the difference to the higher surface tension of water. The onset of electric discharge (Vdis) without SF6, occurred at lower capillary voltages for the negative relative to the positive ion mode for methanol; but Vdis is much higher than Von for methanol, and discharges do not interfere with ESI operation. For water, Von ≈ Vdis in the absence of SF6, in the negative ion mode, and ESI operation is impossible without SF6, discharge suppression. The discharge problem in the positive ion mode is less severe, but SF6, is still very useful. A dynamic range of 10 ?7–10?5 M was obtained by selected ion monitoring of [dCMP - H]? at 4.5 and 20 μL/min. flows. Subpicomole detection limits for the nucleotide salt were obtained under these conditions.  相似文献   

2.
Department of Chemistry, University of New Orleans, New Orleans, Louisiana, USA The effect of solvent composition on negative ion electrospray ionization (ESI) mass spectrometry was examined. The onset potentials for ES1 of a series of chlorinated solvents and methanol were found to be within the range predicted by D. P. H. Smith, based on differences in the surface tension of the solvents used. The tendency toward electric discharge decreased with increasing percent weight of chlorine in the solvent. This effect has been attributed to an increasing propensity for electron capture for more highly chlorinated solvents. Addition of the electron scavenger gas SF, was even more effective at suppressing corona discharge phenomena. In a comparison of ultimate signal intensity obtainable for a test analyte in 10% methanol, the highest signal, which was stable over the widest range of temperatures, was exhibited by chloroform compared to dichloromethane, 1,2-dichloroethane, carbon tetrachloride, and methanol (100%). Chloroform, thus, is a recommended solvent for negative ion electrospray mass spectrometry (ES/MS) when solubility is not a limiting issue. Solvent polarity was shown to exhibit a profound influence on the distribution of charge states in negative ion ES/MS. For both chlorinated and nonchlorinated organic solvents, the higher the solution dielectric constant, the more the charge-state distribution is shifted toward higher charge states. These observations build on the “electrophoretic” mechanism of droplet charging. Solvents with high solution dielectric constants are considered to be most effective at stabilizing multiply charged ions (where charge separation is greatest), and they are likely to increase the level of droplet charging. Solvents with high basicities (gas phase and solution phase) and high proton affinities, yet low dielectric constants, favor lower charge states in ES mass spectra of lipid A and cardiolipin from Escherichia coli. This indicates that gas-phase processes and solvent basicity contribute much less toward ion formation than solution-phase solvation via preferred orientation of the solvent dipole.  相似文献   

3.
Analytical and Chemical Sciences, Research Triangle Institute, Research Triangle Park, North Carolina, USA Negative ion electrospray (ES) operating on a single quadrupole mass spectrometer for the detection of low-molecular-weight molecules is discussed. The ES interface was operated at a positive cylindrical electrode potential to produce negative ions, and the results obtained were compared to the positive ion mode. As in the case of operation in the more common positive mode, negative ions with varying degrees of solvation and structurally relevant fragments can be obtained from a variety of solute species, including β-lactam antibiotics, aminoglycosides, aminocyclitols, tetracyclines, sulfonamides, nucleotides, peptides, and explosives. No fragmentation of parent species, except those from some labile explosives, was provided because low potential differences are applied between the capillary and the first skimmer, and electrical discharge is avoided in the gas phase. An increase in the capillary voltage resulted in collision-induced decomposition to produce structurally relevant fragment ions in both operation modes. An evaluation of representative chromatographic solvents indicated that 2-propanol added with oxygen in the ES bath gas is best suited to suppress electrical (corona) discharge phenomena in negative ion operation, whereas it aids in solution nebulization, desolvation, and transfer of ions in solution to the gas phase. For positive ion mode, no such precaution was necessary. Conditions that promote the formation of ions in solution usually improve ES response. Therefore, an increase in the solvent pH can increase the sensitivity in negative ion ES ionization. Negative ion ES offers the advantage of providing complementary structural information to help in the characterization of an unknown compound or to confirm a certain tentatively proposed structure. Nucleotides and explosives were best characterized in negative ion mode owing to the ease with which they form anions in solution, and they could be detected down to the l-pg /gML level.  相似文献   

4.
We report here the development of a corona discharge (CD) initiated electrochemical (EC) electrospray ionization (ESI) technique using a standard electrospray ion source. This is a new ionization technique distinct from ESI, electrochemistry inherent to ESI, APCI, and techniques using hydroxyl radicals produced under atmospheric pressure conditions. By maximizing the observable CD at the tip of a stainless steel ESI capillary, efficient electrochemical oxidation of electrochemically active compounds is observed. For electrochemical oxidation to be observed, the ionization potential of the analyte must be lower than Fe. Ferrocene labeled compounds were chosen as the electrochemically active moiety. The electrochemical cell in the ESI source was robust, and generated ions with selectivity according to the ionization potential of the analytes and up to zeptomolar sensitivity. Our results indicate that CD initiated electrochemical ionization has the potential to become a powerful technique to increase the dynamic range, sensitivity, and selectivity of ESI experiments.  相似文献   

5.
The factors determining the sensitivity of space-charge-dominated (SCD) unipolar ion sources, such as electrospray (ESP) and corona atmospheric pressure ionization (API) have been studied theoretically. The most important parameters are the ion density and ion drift time in the vicinity of the sampling orifice. These are obtained by solving a system of differential equations, “the space-charge problem.” For some simple geometries, analytical solutions are known. For a more realistic “needle-in-can” geometry, a solution to the space-charge problem was obtained using a finite-element method. The results illustrate some general characteristics of SCD ion sources. It is shown that for typical operating conditions the minimum voltage required to overcome the space-charge effect in corona API or ESP ion sources constitutes a dominant or significant fraction of total applied voltage. Further, the electric field and the ion density in the region of the ion-sampling orifice as well as the ion residence time in the source are determined mainly by the space charge. Finally, absolute sensitivities of corona API ion sources were calculated by using a geometry-independent treatment of space charge.  相似文献   

6.
The mechanism of atmospheric pressure (AP) laser ionization of water and water/glycerol liquid samples at a 3-microm wavelength is studied experimentally. For the ion desorption, an in-house built Yb : YAG-pumped optical parametric oscillator (OPO) infrared (IR) laser has been coupled with AP MALDI ion source interfaced to an ion trap mass spectrometer (MS). It has been shown that water is primarily responsible for ion generation in water/glycerol samples, while glycerol increases the solution viscosity and decreases the water evaporation rate and sample losses. In contrast to AP UV-MALDI, the electric field in the case of AP IR-MALDI does not assist in ion production. It was found that the absence of the electrical field provides the optimum ionization condition both for water and water/glycerol liquid samples at the 3-microm laser irradiation. A two-stage ion formation mechanism, which includes the initial emission of microdroplets and release of molecular ions at the second stage, can explain the experimentally observed ion signal dependencies upon the voltage applied between MS inlet and the MALDI sample plate. Postionization using additional corona discharge APCI increases the observed signal by approximately 50%, which indicates that some portion of the analyte is desorbed in the form of neutral molecules.  相似文献   

7.
Charge assisted laser desorption/ionization mass spectrometry of droplets   总被引:1,自引:1,他引:0  
We propose and evaluate a new mechanism to account for analyte ion signal enhancement in ultraviolet-laser desorption mass spectrometry of droplets in the presence of corona ions. Our new insights are based on timing control of corona ion production, laser desorption, and peptide ion extraction achieved by a novel pulsed corona apparatus. We demonstrate that droplet charging rather than gas-phase ion-neutral reactions is the major contributor to analyte ion generation from an electrically isolated droplet. Implications of the new mechanism, termed charge assisted laser desorption/ionization (CALDI), are discussed and contrasted with those of the laser desorption atmospheric pressure chemical ionization method (LD-APCI). It is also demonstrated that analyte ion generation in CALDI occurs with external electric fields about one order of magnitude lower than those needed for atmospheric pressure matrix assisted laser desorption/ionization or electrospray ionization of droplets.  相似文献   

8.
Three plasma-based ambient pressure ion sources were investigated; laboratory constructed dielectric barrier and rf glow discharges, as well as a commercial corona discharge (DART source). All were used to desorb and ionize a model analyte, providing sampling techniques for ambient mass spectrometry (MS). Experimental parameters were optimized to achive highest signal for acetaminophen as the analyte. Insight into the mechanisms of analyte desorption and ionization was obtained by means of emission spectrometry and ion current measurements. Desorption and ionization mechanisms for this analyte appear to be identical for all three plasma sources. Emission spectra differ only in the intensities of various lines and bands. Desorption of solid analyte requires transfer of thermal energy from the plasma source to sample surface, in the absence of which complete loss of MS response occurs. For acetaminophen, helium was the best plasma gas, providing 100- to 1000-fold higher analyte response than with argon or nitrogen. The same trend was also evident with background ions (protonated water clusters). MS analyte signal intensity correlates with the ion density (expressed as ion current) in the plasma plume and with emission intensity from excited state species in the plasma. These observations support an ionization process which occurs via proton transfer from protonated water clusters to analyte molecules.  相似文献   

9.
In previous studies, the production of ions in an APCI source without any corona discharge was observed, and the intensity of the ion signals showed significant increases on placing a metallic surface at 45 degrees inside an orthogonal ion source. This method was named surface-activated chemical ionization (SACI). The present study was performed to investigate the mechanisms of ion production with or without the presence of the metallic surface, by varying instrumental parameters and the geometrical configuration. Approximate calculations show that, in the absence of corona discharge and of any additional surfaces, ions cannot be produced by collisional phenomena, because of their low kinetic energy, in the 10(-2) to 10(-3) eV range. Two alternative possibilities have been considered: the first takes into account that ions may originate by collision of neutral clusters of polar solvent molecules with the APCI source surfaces through clusterelectric effect. The second takes into account that the water dissociation constant k(w) is temperature dependent, passing from 10(-14.1669) at 20 degrees C to 10(-12.4318) at 90 degrees C. It means that the [H(+)] varies from 8.3 x 10(-8) to 6.1 x 10(-7) M going from 20 to 90 degrees C. Hence, at the high temperatures experimented in the APCI vaporizer, H(+) becomes available in solution in molar quantities analogous to those of analyte, and the protonation of the analyte itself can consequently occur. The activation of further ionization processes in the presence of the metallic surface can be reasonably attributed to interactions between gas-phase analyte molecules and solvent molecules adsorbed on the surface. Experiments performed with a thin layer of deuterated glycerol on the surface led to unequivocal results, i.e. the production of [M + D](+) ions of the analyte.  相似文献   

10.
Atmospheric humidity causes the major problem using ion mobility spectrometers (IMS) under ambient conditions. Significant changes of the spectra are decreasing sensitivity as well as selectivity. Therefore, the influence of humidity on the IMS signal was investigated in case of direct introduction of the analyte into the ionisation chamber and in case of pre-separation by help of a multi-capillary column (MCC). For direct analyte introduction, a significant decrease of the total number of ions in the range of 28-42% with increasing relative humidity was found. Simultaneously additional peaks in the spectra were formed, thus complicating the identification of the analytes. In case of pre-separation of the analyte, the spectra do not change with increasing relative humidity, due to the successive appearance of the analyte and the water molecules in the ionisation chamber. Detection limits were found in the range of 5 μg/m3 (about 1 ppbv) for selected terpenes and—with pre-separation—independent on relative humidity of the analyte. Without pre-separation, detection limits are in the same range for dry air as carrier gas but in the range of 200-600 μg/m3 when relative humidity reaches 100%. Thus, MCC-UV ion mobility spectrometry is optimally capable for the detection of trace substances in ambient air (e.g. indoor air quality control, process control, odour detection) without further elaborate treatment of the carrier gas containing the analyte and independent on relative humidity.  相似文献   

11.
The major reactant ion in conventional ion mobility spectrometry (IMS) is the hydronium ion, H3O+ which is produced in the usual ionization sources such as corona discharge or radioactive sources. Using the hydronium reactant ion, mostly the analytes with proton affinity higher than that of water are ionized. A broader range of compounds can be detected by IMS if other alternative ionization channels, such as charge transfer from NO+, are employed. In this work we introduce a simple and novel method for producing NO+ as the major reactant ion in IMS. This was achieved by adding neutral NO to the corona discharge ionization source. The neutral NO was prepared via an additional discharge in an air stream, flowing into the corona discharge source. A curtain plate was mounted in front of the corona discharge to prevent the influence of the analyte on the production of NO+. Using this technique, the reactant ion could easily and quickly switch between the H3O+ and NO+. The performance of the new source was evaluated by recording ion mobility spectra of test compounds with both H3O+ and NO+ reactant ions.  相似文献   

12.
Despite the recent, successful efforts to detect mycotoxins, new methods are still required to achieve higher sensitivity, more simplicity, higher speed, and higher accuracy at lower costs. This paper describes the determination of ochratoxin A (OTA) using corona discharge ion mobility spectrometry (IMS) in the licorice root. A quick screening and measuring method is proposed to be employed after cleaning up the extracted OTA by immunoaffinity columns. The ion mobility spectrometer is used in the inverse mode to better differentiate the OTA peak from the neighboring ones. After optimization of the experimental conditions such as corona voltage, injection port temperature, and IMS cell temperature, a limit of detection (LOD) of 0.010 ng is obtained. Furthermore, the calibration curve is found to be in the range of 0.01-1 ng with a correlation coefficient (R2) of 0.988. Licorice roots were analyzed for their OTA content to demonstrate the capability of the proposed method in the quantitative detection of OTA in real samples.  相似文献   

13.
In this work, the microextraction in packed syringe technique combined with corona discharge ion mobility spectrometry was used for determining diazinon in water samples. A new porous composite of nanoclay and polysiloxane was prepared using a sol–gel process. An amount of 2.0 mg of the sorbent was packed in a 250 μL syringe and used for extraction. A volume of 2 mL of the sample was passed through the sorbent bed, and the entrapped analyte was eluted by 25 μL of methanol. Important parameters influencing the extraction performance were investigated. Under optimum experimental conditions, the detection limit for diazinon was 0.07 ng/mL. The intra‐ and inter‐day relative standard deviations were 5.0 and 12.3%, respectively. The calibration curve was linear in the concentration range from 0.2 to 20.0 ng/mL (r= 0.999). The applicability of the method was demonstrated by analyzing spiked real water samples and the spiking recoveries were in the range of 95 to 106%.  相似文献   

14.
Matrix assisted laser desorption/ionization (MALDI) is studied at atmospheric pressure using liquid sampling methods. A time-of-flight mass spectrometer couples to an open sample stage accessed by a UV laser for desorption and ionization. Also coupled to the sampling state is a corona discharge for auxiliary ionization of desorbed neutral molecules. The interaction of the laser desorption and corona ionization is studied for a range of desorption conditions, showing enhanced analyte ionization, but the effect is analytically advantageous only at low desorption rates. The effect of corona discharge voltage was also explored. The decoupling of neutral molecule formation and subsequent ionization provides an opportunity to study each process separately.  相似文献   

15.
The technique of atmospheric pressure photoionization (APPI) has several advantages over electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI), including efficient ionization of nonpolar or low charge affinity compounds, reduced susceptibility to ion suppression, high sensitivity, and large linear dynamic range. These benefits are greatest at low flow rates (i.e., 相似文献   

16.
We present the design and implementation of a home-built point-to-plane corona discharge probe, which rapidly and efficiently charge reduces biological ions generated by electrospray ionization (ESI). The molecules analysed ranged from small peptides such as Glu-fibrinopeptide B (1.5 kDa), small proteins such as myoglobin (16.9 kDa), polymers such as polyethylene glycol (PEG 10 k) which all showed intense singly charged ions; to large native multiprotein complexes such as GroEL (802 kDa) which show a broad range of charge-reduced species. The corona discharge probe operates at atmospheric pressure and was directly interfaced with a standard-ESI or nanoflow-ESI source of quadrupole ion mobility time-of-flight mass spectrometer. The corona discharge probe is completely modular and could potentially be mounted to any commercial or research grade mass spectrometer with an ESI source. The level of charge reduction is precisely controlled by the applied voltage and/or probe gas flow rate and when in operation, results in approximately a 50 % reduction in total ion current. We also present the combination of corona discharge and travelling wave ion mobility and assign helium collision cross-section values (ΩHe) to the charge reduced species of the native protein complex pyruvate kinase. It would appear that the ΩHe of the +20 charge state for pyruvate kinase is approximately 20 % smaller than the +35 charge state. Finally, we discuss the potential benefits and concerns of utilising charge reduced protein species as a means of extending the travelling wave collision cross-section calibration range over that which is already published.  相似文献   

17.
OH radical in the corona discharge with pipe–nozzle–plate electrode has been diagnosed by optical emission spectroscopy. Spatial variations of OH radical emission in discharge gap have been measured. Relative intensity of OH radical emission spectroscopy increases with increasing water vapor flux injected into the reactor or intensity of electric field supported. In positive pulsed corona discharge, relative intensity is higher than that in positive DC corona discharge and lower than that in negative DC corona discharge. Strongest intensity of OH radical spectrum appears within the range of 5 mm near the discharge nozzle- electrode. In addition, it is proved that the efficiency of desulphurization from flue gas by pulsed corona discharge plasma processes can be improved when OH radical is produced in the reactor.  相似文献   

18.
Jafari MT  Khayamian T 《Talanta》2008,76(5):1189-1193
In this study, direct determination of ammoniacal nitrogen residues in water samples using corona discharge ion mobility spectrometry (CD-IMS) was investigated. Pyridine was used as an alternate reagent gas to enhance selectivity and sensitivity of the method. The results indicate that the limit of detection (LOD) was about 9.2x10(-3)mugmL(-1) and the linear dynamic range was obtained from 0.03 to 2.00mugmL(-1). The relative standard deviation was about 11%. Furthermore, this method was successfully applied to the direct determination of ammoniacal nitrogen in river and tap water samples and the results were compared with the Nessler method. The comparison of the results validates the potential of the proposed method as an alternative technique for the analysis of the ammoniacal nitrogen in water samples.  相似文献   

19.
Corona discharge ionization sources are often used in ion mobility spectrometers (IMS) when a non-radioactive ion source with high ion currents is required. Typically, the corona discharge is followed by a reaction region where analyte ions are formed from the reactant ions. In this work, we present a simple yet sufficiently accurate model for predicting the ion current available at the end of this reaction region when operating at reduced pressure as in High Kinetic Energy Ion Mobility Spectrometers (HiKE-IMS) or most IMS-MS instruments. It yields excellent qualitative agreement with measurement results and is even able to calculate the ion current within an error of 15%. Additional interesting findings of this model are the ion current at the end of the reaction region being independent from the ion current generated by the corona discharge and the ion current in High Kinetic Energy Ion Mobility Spectrometers (HiKE-IMS) growing quadratically when scaling down the length of the reaction region.
Graphical Abstract ?
  相似文献   

20.
Mobilities of 11 substituted benzoates and 3 nitrophenolates were determined in non-aqueous methanol with Li+, Na+, K+, Rb+, and tetrabutylammonium (Bu4N+) as counter-ions of the background electrolyte. The influence of the ionic concentration of the background electrolyte on the mobility of the analyte anions is more pronounced compared to aqueous solutions. The deviation from the dependence of the mobilities on the ionic strength from the Debye-Hückel-Onsager theory indicates the occurrence of ion-pair formation. For a given ion concentration (10 mmol/L), the decrease of the analyte mobility follows the counter-ion sequence Li+ < Na+ < K+ < Rb+, which is the inverse order of their Stokes radii. Bu4N+ as counter-ion has a similar effect on the analyte mobility than Li+ (which has the same Stokes radius, but a six times smaller crystal radius). Exceptions are some di- and trihydroxybenzoates. The mobilities in methanol and in water with the same counter-ion (Na+) at a given ionic concentration show very low correlation.  相似文献   