首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Zhen Hai Li  Koji Oshita 《Talanta》2010,82(4):1225-637
Flow-injection analysis system (FIA system), which was based on Fe(II)-catalyzed oxidation of chromotropic acid with hydrogen peroxide, was developed for the determination of hydrogen peroxide. The chromotropic acid has a fluorescence measured at λem = 440 nm (emission wavelength) with λex = 235 nm (excitation wavelength), and the fluorescence intensity at λem = 440 nm quietly decreased in the presence of hydrogen peroxide and Fe(II), which was caused by Fe(II)-catalyzed oxidation of chromotropic acid with hydrogen peroxide. By measuring the difference of fluorescence intensity, hydrogen peroxide (1.0 × 10−8-1.0 × 10−3 mol L−1) could be determined by the proposed FIA system, whose analytical throughput was 40 samples h−1. The relative standard deviation (RSD) was 1.03% (n = 10) for 4.0 × 10−8 mol L−1 hydrogen peroxide. The proposed FIA technique could be applied to the determination of hydrogen peroxide in rain water samples.  相似文献   

2.
A novel flow injection analysis (FIA) system based on liquid-liquid microextraction and fluorimetric determination was developed for the determination of traces of the Zn2+ ion using 5-(8-hydroxy-2-quinolinylmethyl)-2,8-dithia-5-aza-2,6-pyridinophane (L) as a sensitive and selective fluorimetric sensor, with λex = 373 nm and λem = 530 nm, and hexanol as the extracting organic solvent. In the designed FIA system, the phase separation takes place via gravitation forces in the absence of any segmenter. The influence of pH and ionic strength of the solution, amount of ligand, nature of counter ion, volume of organic solvent, extraction time and coil length was investigated. Under optimized experimental conditions, the calibration curve found to be liner over a concentration range of 0.025-4.53 μg mL−1 (R2 = 0.9951) with a limit of detection of 2.3 ng mL−1. The enrichment factor was 45 and relative standard deviation for 7 replicate determinations was 2.43%. The method is very fast and uses low levels of organic solvents. The proposed method was applied successfully to the determination of zinc(II) in human hair, human serum and two inorganic sludge samples.  相似文献   

3.
Fluorescence and terbium-sensitised luminescence properties of new quinolone garenoxacin have been studied. The fluorimetric method allows the determination of 0.060-0.600 μg ml−1 of garenoxacin in aqueous solution containing HCl/KCl buffer (pH 1.5) with λexc=282 nm and λem=421 nm. Micellar-enhanced fluorescence was also studied, leading to a higher than 400% increase in analytical signal in presence of 12 mM sodium dodecyl sulphate (SDS), allowing the determination of 0.020-0.750 μg ml−1 of garenoxacin. The terbium-sensitised luminescence method allows the determination of 0.100-1.500 μg ml−1 of garenoxacin in 12 mM SDS solution containing 0.08 M acetic acid/sodium acetate buffer (pH 4.1) and 7.5 mM Na2SO3 (chemical deoxygenation agent), with λexc=281 nm and λem=546 nm. Relative standard deviation (R.S.D.) values for the three methods were in the range 1.0-2.0%. The proposed procedures have been applied to the determination of garenoxacin in spiked human urine and serum.  相似文献   

4.
A high-performance liquid chromatographic method has been developed for the determination in human plasma of the specific serotonin reuptake inhibitor (SSRI) antidepressant paroxetine and its three main metabolites (M1, M2, M3). Fluorescence detection was used, exciting at λ = 294 nm and monitoring emission at λ = 330 nm for paroxetine (λexc = 280 nm, λem = 330 nm for M1 and M2; λexc = 268 nm, λem = 290 nm for M3). Separation was obtained on a reversed-phase C18 column using a mobile phase composed of 66.7% aqueous phosphate at pH 2.5 and 33.3% acetonitrile. Imipramine (λexc = 252 nm, λem = 390 nm) was used as the internal standard. A careful pre-treatment of plasma samples was developed, using solid-phase extraction with C8 cartridges (50 mg, 1 mL). The calibration curves were linear over a working range of 2.5-100 ng mL−1 for paroxetine and of 5-100 ng mL−1 for all metabolites. The limit of detection (LOD) was 1.2 ng mL−1 for PRX and 2.0 ng mL−1 for the metabolites. The method was applied with success to plasma samples from depressed patients undergoing treatment with paroxetine. Hence, the method seems to be suitable for the therapeutic drug monitoring of paroxetine and its main metabolites in depressed patients’ plasma.  相似文献   

5.
In this work, and for the first time, it was developed an automatic and fast screening miniaturized flow system for the toxicological control of glibenclamide in beverages, with application in forensic laboratory investigations, and also, for the chemical control of commercially available pharmaceutical formulations. The automatic system exploited the multipumping flow (MPFS) concept and allowed the implementation of a new glibenclamide determination method based on the fluorometric monitoring of the drug in acidic medium (λex = 301 nm; λem = 404 nm), in the presence of an anionic surfactant (SDS), promoting an organized micellar medium to enhance the fluorometric measurements.The developed approach assured good recoveries in the analysis of five spiked alcoholic beverages. Additionally, a good agreement was verified when comparing the results obtained in the determination of glibenclamide in five commercial pharmaceutical formulations by the proposed method and by the pharmacopoeia reference procedure.  相似文献   

6.
A normal spectrophotometric and a stopped-flow (SF) spectrofluorimetric method have been developed and optimized for the determination of alendronic acid (ALD) in its pharmaceutical formulations. Both methods are automated using the sequential injection analysis (SIA) principle. The spectrophotometric assay is based on the reaction of the analyte with Cu(II) ions in acidic medium to form an UV-absorbing derivative (λmax = 240 nm). The SF spectrofluorimetric method is based on the reaction of ALD with o-phthalaldehyde (OPA) in the presence of 2-mercaptoethanol at basic medium (λex = 340 nm/λem = 455 nm). Linear calibration curves were obtained in the range 1.0-60.0 mg l−1 ALD for the UV method, and in the range 0.13-10.0 mg l−1 ALD for the SF spectrofluorimetric one. The sampling rates were 60 and 30 h−1, respectively. The developed assays are critically compared and their advantages are discussed. Both methods were applied to the analysis of an ALD containing pharmaceutical formulation with satisfactory accuracy and precision.  相似文献   

7.
Two accurate, reliable, and highly sensitive spectrofluorimetric methods were developed for simultaneous determination of binary mixture gemfibrozil and rosiglitazone in human plasma without prior separation steps. The first method is based on synchronous fluorescence spectrometry using double scans. At Δλ = 27 nm, gemfibrozil yields detectable signal that is independent of the presence of rosiglitazone. Similarly, at Δλ = 120 nm the signal of rosiglitazone is not influenced by the presence of gemfibrozil. Signals at two wavelengths, 301 (Δλ = 27 nm) and 368 nm (Δλ = 120 nm) vary linearly with gemfibrozil and rosiglitazone concentrations over the range 100-700 ng mL−1 (for gemfibrozil) and 20-140 ng mL−1 (for rosiglitazone), respectively. The limits of detection (LOD) were 2.3 and 2.72 ng mL−1 for gemfibrozil and rosiglitazone, respectively. The second method is based on the technique of simultaneous equations (Vierodt's method), in which 258 nm was selected as the excitation wavelength. Two equations are constructed based on the fact that at (λEm2=302 nm of gemfibrozil) and (λEm2=369 nm of rosiglitazone) the fluorescence of the mixture is the sum of the individual fluorescence of gemfibrozil and rosiglitazone. The limits of detection (LOD) were 28.1 and 23.63 ng mL−1 for gemfibrozil and rosiglitazone, respectively. The proposed methods were successfully applied for the determination of the two compounds in synthetic mixtures and in human plasma with a good recovery.  相似文献   

8.
A new, simple and highly sensitive method for spectrofluorimetric determination of amiloride (AMI) and furosemide (FUR) in pharmaceuticals is presented. The proposed method is based on the separation of AMI from FUR by solid-phase extraction using a nylon membrane, followed by spectrofluorimetric determination of both drugs, on the solid surface and the filtered aqueous solution, respectively. AMI shows low native fluorescence, but its separation-preconcentration by immobilization (solid-phase extraction) on nylon membrane surface provides a considerable enhancement in fluorescence intensity. The fluorescence determination is carried out at λex = 237, λem = 415 nm for FUR; and λex = 365, λem = 406 nm for AMI. The calibration graphs are linear in the range 3.20 × 10−4 to 0.8 μg mL−1and 1.33 × 10−3 to 4.0 μg mL−1, for AMI and FUR, respectively, with a detection limit of 9.62 × 10−5 and 4.01 × 10−4 μg mL−1 (S/N = 3). The commonly found excipients in commercial pharmaceutical formulations do not interfere. The developed method is successfully applied to the determination of both drugs in pharmaceutical formulations.  相似文献   

9.
Zisiou EP  Pinto PC  Saraiva ML  Siquet C  Lima JL 《Talanta》2005,68(2):226-230
A sensitive sequential injection analysis (SIA) methodology for the fluorimetric determination of naproxen is proposed. The developed automatic analytical procedure is based on the complexation of naproxen with β-cyclodextrin (β-CD) yielding an enhanced fluorimetric signal (λex = 280 nm, λem = 356 nm).Linear calibration plots were obtained for naproxen concentrations up to 1 × 10−5 mol l−1. The developed methodology exhibited a good precision, with a R.S.D. < 2.1% (n = 15). The detection limit of the determination was 1.9 × 10−7 mol l−1 with a sampling rate of about 70 h−1. The automatic method was applied to the determination of naproxen in pharmaceutical formulations. The obtained results were compared with those furnished by the reference procedure and the relative deviations were lower than 3.6%. No interference was found from the excipients usually used in solid pharmaceutical formulations.  相似文献   

10.
A new, simple and sensitive spectrofluorimetric method for the determination of salicylic acid (λex = 315 nm, λem = 408 nm) using As(III) as a sensitizing reagent has been investigated by measuring the increase of fluorescence intensity of salicylic acid due to the complexation of As(III)-salicylic acid in presence of sodium dodecyl sulfate (SDS) 10−3 M. Under optimum conditions, a significant relationship was obtained between the fluorescence intensity and salicylic acid concentration. A linear calibration curve was obtained in the range 13.8-13812 μg l−1 with product-moment correlation coefficient (R) 0.99985 and detection limit 4.2 μg l−1. The R.S.D. is 2.35% (n = 5).The method was applied successfully to the determination of salicylic acid in human serum.  相似文献   

11.
Xia Gao  Gui-qin Shang 《Talanta》2007,73(4):770-775
A new highly sensitive and selective colorimetric method for fluoride determination in water is described. The novel reagent used is a hemicyanine dye (HC), which forms a stable complex with Zr-EDTA, the fluoride-binding site, through the hydroxyl groups. The hemicyanine-chelating Zr-EDTA complex (HC-Zr-EDTA) is ready to react with fluoride ion to release HC. This result in remarkable color change of the sensing solutions from red (λmax = 513 nm) to yellow (λmax = 427 nm) at pH 4.40. When applied to the colorimetric determination of fluoride ions, a linear range from 3.0 × 10−6 to 5.0 × 10−5 mol/L and a detection limit of 2.8 × 10−6 mol/L with a correlation coefficient of 0.9993 can be achieved under the optimized conditions. Because of the specific affinity of fluorides for the [Zr-EDTA], there is little interference by other ions. This method has been successfully applied to the determination of fluorides in toothpaste samples.  相似文献   

12.
Teshima N  Fernández SK  Ueda M  Nakai H  Sakai T 《Talanta》2011,84(5):1205-1208
A flow injection (FI) spectrophotometric method is proposed for the determination of low concentration of formaldehyde (HCHO) in liquid media. It is based on the condensation of HCHO with hydroxylamine sulfate, followed by the reduction reaction of iron(III)-ferrozine complex with the residual hydroxylamine to form a purple iron(II)-ferrozine complex (λmax = 562 nm). In the first reaction, hydroxylamine decreases proportionally to the concentration of HCHO, and therefore the produced purple iron(II)-ferrozine complex decreases with increasing HCHO (a negative FI peak is obtained). The detection limit (S/N = 3) was 1.6 μg L−1. The method can be applied to the determination of HCHO in industrial wastewater.  相似文献   

13.
Biswas S  Chowdhury B  Ray BC 《Talanta》2004,64(2):308-312
A highly sensitive and virtually specific method has been developed for the trace and ultra trace 5 ng ml−1-1 μg ml−1 fluorimetric analysis of nitrite. The method is based on the quenching action of nitrite on the native fluorescence of murexide (ammonium purpurate) [λex=349.0 nm, λem=444.5 nm] in the acid range of 0.045-0.315 (M) H2SO4. The method is very precise and accurate (S.D.=±0.4877 and R.S.D.=0.4878% for the determination of 0.1 μg ml−1 of nitrite in 11 replicates). Relatively large excesses of over 35 cations and anions do not interfere. The proposed technique has been successfully applied for the determination of nitrite and nitrate in ground water, surface water and sea water, nitrite in soil and nitrate in forensic samples. The method has also been extended for the analysis of NOx in air.  相似文献   

14.
A highly sensitive catalytic quenching spectrofluorimetric method was described for the determination of V(V) based on its catalytic effect on the oxidation of 1,8-diaminonaphthalene by potassium bromate with Tiron as an activator in weakly acidic medium and the reaction mechanism was investigated. The reaction was followed spectrofluorimetrically by measuring the fluorescence intensity of 1,8-diaminonathphlene (DAN) (λex=356 nm, λem=439 nm) at a fixed time of 5 min from initiation of the reaction. Under the optimum conditions, vanadium(V) can be determined in the range 0.05-50.0 ng ml−1 with a S.D.=0.024 for 15 times measurements. The detection limit of the method was down to 0.0088 ng ml−1 and the catalytic reaction activation energy was found to be 43.92 kJ mol−1. The proposed method was tested for the determination of vanadium(V) in rice and natural water samples.  相似文献   

15.
A flow injection analysis (FIA) procedure for the determination of anisidine value (AV) in palm olein using a triiodide detector is described. Undiluted oil sample and chloramine-T reagent were added to a reaction chamber, and reaction was accelerated by applying a short vortex action (typically for 30 s). After allowing the emulsified oil phase to be separated from the aqueous phase (bottom layer), an aliquot of the aqueous phase (containing unreacted chloramine-T) was aspirated into a carrier stream that contained I where the chloramine-T oxidized the I to form I3 which was finally detected by a flow-through triiodide potentiometric detector. Variables that affect the FIA signals such as size of the reaction chamber, oil and reagent flow rates, chloramine-T concentration, vortex time, time for phase separation, carrier stream pH and injected volume were studied. The optimized FIA procedure is linear over 1.0-23.0 AV. The method exhibits good repeatabililty (R.S.D. of ±3.16% (n = 4) for the determination of 5.0 AV) and a sampling rate of 40 samples per hour was achieved. Good correlation (r2 = 0.996 (n = 4)) between the proposed method and the manual American Oil Chemists’ Society procedure was found when applied to the determination of twenty different types of palm olein samples.  相似文献   

16.
This study reports a sensitive solvent extraction flow-injection (FI) method for the simultaneous spectrophotometric determination of free cyanide and thiocyanate in human saliva and pralidoxime solutions. Cyanide and thiocyanate form colored (λmax=540 nm) ternary complexes with copper and 2,2′-dipyridyl-2-quinolylhydrazone (DPQH) that are extractable into chloroform. The determination of thiocyanates in the presence of cyanides is accomplished after on-line masking of the latter with formaldehyde through a binary inlet static mixer (BISM). Total thiocyanates and cyanides are determined in a second run, without the use of the masking agent. The proposed method allows the determination of the analytes in the range of 0-4 mg l−1 thiocyanates and 0-3 mg l−1 cyanides, with the 3σ detection limits being 0.007 and 0.004 mg l−1, respectively. The precision of the method (sr<1.0% at 1 mg l−1 CN or SCN, n=12 in both cases) and the sampling rates were quite satisfactory (60 injections per hour). The method was applied to the analysis of human saliva and pralidoxime solutions and gave recoveries in the range of 98.0-102.2% for both analytes whereas the mean relative error was er=1.7%.  相似文献   

17.
A flow injection analysis (FIA) method for the determination of peroxide value (PV) in edible oils is described. Oil sample (undiluted) and KI reagent were aspirated into a homemade reaction chamber where the redox reaction between iodide in the aqueous phase and hydroperoxides in the oil was effected by applying a short (typically 30 s) vortex action. After allowing for the emulsified oil phase to be separated from the aqueous phase (bottom layer), an aliquot of the aqueous phase containing triiodide was next aspirated to the surface of a triiodide-selective membrane for detection. The optimized FIA procedure is linear over 0.35-28.0 PV (mequiv. O2/kg) with a detection limit of 0.32 PV. Exhibiting good reproducibility (R.S.D. of 2.7% (n = 8) for the determination of 1.1 PV) and sampling rate of 80 samples h−1, the proposed method, unlike previous FIA procedures, completely eliminated the use of organic solvents (except the use of 2-propanol for cleaning of reaction chamber). Excellent correlation (R2 = 0.9949) between the proposed method and the manual official AOCS method was found when applied to the determination of PV in diverse type of edible oils (n = 20).  相似文献   

18.
The nickel-aluminum layered double hydroxide (Ni-Al LDH) was synthesized by a simple co-precipitation method and used as a solid-phase extraction (SPE) sorbent for separation and pre-concentration of trace levels of salicylic acid (SA) from aqueous solutions. Extraction of analyte is based on the adsorption of salicylate ions on the Ni-Al (NO3) LDH and/or their exchanging with LDH interlayer NO3 ions. The retained analyte on the LDH was stripped by 3 mol L−1 NaOH solution and its concentration was subsequently determined spectrofluorometrically at λem = 400 nm with excitation at λex = 270 nm. Various parameters affecting the extraction efficiency of SA on the Ni-Al (NO3) LDH, such as pH, amount of nano-sorbent, sample loading flow rate, elution conditions, sample volume and matrix effects were investigated. In the optimum experimental conditions, the limit of detection (3 s) and enrichment factor were 0.12 μg L−1 and 40, respectively. The relative standard deviation (RSD) for six replicate determinations of 10 μg L−1 SA was 2.3%. The calibration graph using the pre-concentration system was linear in the range of 0.3-45 μg L−1 with a correlation coefficient of 0.9985. The optimized method was successfully applied to the determination of SA in blood serum, willow leaf and aspirin tablet.  相似文献   

19.
Based on the characteristics of synchronous fluorescence spectroscopy (SFS), a new method with high sensitivity and selectivity was developed for rapid determination of silver ion with functional cadmium sulphide (CdS) nanoparticles as a fluorescence probe. When Δλ (λem − λex) = 215 nm, maximum synchronous fluorescence is produced at 304 nm. Under optimal conditions, functional cadmium sulphide displayed a calibration response for silver ion over a wide concentration range from 0.8 × 10−10 to 1.5 × 10−8 mol L−1. The limit of detection was 0.4 × 10−10 mol L−1 and the relative standard deviation of seven replicate measurements for the lowest concentration (0.8 × 10−10 mol L−1) was 2.8%. Compared with several fluorescence methods, the proposed method had a wider linear range and improved the sensitivity. Furthermore, the concentration dependence of the synchronous fluorescence intensity is effectively described by a Langmuir-type binding isotherm.  相似文献   

20.
The present work reports the first spectrofluorimetric gas-diffusion flow injection (GD-FI) assay for the determination of chlorine dioxide in water samples (tap, mineral and soda water). The method is based on the fluorescence quenching of chromotropic acid (CA) (λex. = 347 nm, λem. = 371 nm) caused by the analyte. The chemical and instrumental variables of the system were studied in terms of maximum sensitivity. The gas-diffusion cell was thermostated at 40 °C to enhance the vaporization of chlorine dioxide and thus the sensitivity of the method. The quenching effect of chlorine dioxide on CA was linear in the range 0.09-3.41 mg l− 1, while the precisions either close to the quantitation limit or near to the middle of the linear section of the calibration graph were satisfactory in both cases (sr = 2.6% and 1.5% (n = 10) at 0.17 and 1.71 mg l− 1 level, respectively). The developed method proved to be adequately selective and sensitive with 3σ limit of detection equal to cL = 0.03 mg l− 1. The application of the assay to spiked tap, mineral and soda water samples yielded accurate results with recovery values in the range 94.1-105.9%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号