首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 109 毫秒
1.
Here, task‐specific ionic liquid solid‐phase extraction is proposed for the first time. In this approach, a thiourea‐functionalized ionic liquid is immobilized on the solid sorbent, multiwalled carbon nanotubes. These modified nanotubes packed into a solid‐phase extraction column are used for the selective extraction and preconcentration of ultra‐trace amounts of lead(II) from aqueous samples prior to electrothermal atomic absorption spectroscopy determination. The thiourea functional groups act as chelating agents for lead ions retaining them and so, give the selectivity to the sorbent. Elution of the retained ions can be performed using an acidic thiourea solution. The effects of experimental parameters including pH of the aqueous solution, type and amount of eluent, and the flow rates of sample and eluent solutions on the separation efficiency are investigated. The linear dependence of absorbance of lead on its concentration in the initial solution is in the range of 0.5–40.0 ng/mL with the detection limit of 0.13 ng/mL (3sb/m, n = 10). The proposed method is applicable to the analysis of red lipstick, pine leaves, and water samples for their lead contents.  相似文献   

2.
3.
Novel poly(ionic liquids) were synthesized and immobilized on prepared magnetic nanoparticles, which were used to extract pesticides from fruit and vegetable samples by dispersive solid‐phase extraction prior to high‐performance liquid chromatography analysis. Compared with monomeric ionic liquids, poly(ionic liquids) have a larger effective contact area and higher viscosity, so they can achieve higher extraction efficiency and be used repeatedly without a decrease in analyte recovery. The immobilized poly(ionic liquids) were rapidly separated from the sample matrix, providing a simple approach for sample pretreatment. The nature and volume of the desorption solvent and amount of poly(ionic liquid)‐modified magnetic material were optimized for the extraction process. Under optimum conditions, calibration curves were linear (R2 > 0.9988) for pesticide concentrations in the range of 0.100–10.000 μg/L. The relative standard deviations for repeated determinations of the four analytes were 2.29–3.31%. The limits of detection and quantification were 0.29–0.88 and 0.97–2.93 μg/L, respectively. Our results demonstrate that the developed poly(ionic liquid)‐modified material is an effective absorbent to extract pesticides from fruit and vegetable samples.  相似文献   

4.
Room temperature ionic liquids are regarded as “Green solvents” for their nonvolatile and thermally stable properties. They are employed to replace traditional volatile organic solvents in organic synthesis, solvent extraction, and electrochemistry. In this work, a water immiscible room temperature ionic liquid, 1‐butyl‐3‐methylimidazolium hexafluorophosphate [C4mim][PF6], was used as an alternative solvent for liquid/liquid extraction of copper ions. Metal chelators, including dithizone, 8‐hydroxyquinoline, and 1‐(2‐pyridylazo)‐2‐naphthol, were employed to form neutral metal‐chelate complexes with copper ions so that copper ions were extracted from aqueous solution into [C4mim][PF6]. The parameters that affect the extraction of copper ions with this biphasic system were investigated. The extraction behavior in this novel biphasic system is shown to be consistent with that of traditional solvents. For example, the extraction with this biphasic system is strongly pH dependent. So, the extraction efficiency of coppers ion from an aqueous phase can be manipulated by tailoring the pH value of the extraction system. Hence, the extraction, separation and preconcentraction of copper ions can be accomplished by controlling the pH value of the extraction system. It appears that the use of ionic liquid as an alternate solvent system in liquid/liquid extraction of copper ions is very promising.  相似文献   

5.
不同离子液体双水相萃取钯   总被引:3,自引:0,他引:3  
为实现贵金属钯的绿色、高效萃取,本文使用有“绿色溶剂”之称的离子液体与磷酸钾形成的双水相体系,不加入其它萃取剂对钯(Ⅱ)进行萃取,并采用浊点法对所研究的6种咪唑类离子液体的双结线和系线进行测定。 结果表明,基于氯离子和溴离子的离子液体成相能力和萃取率无显著差异。 阳离子上支链的疏水性是影响咪唑类离子液体成相能力的关键因素之一。 与不含官能团的离子液体相比,支链上嵌入氨基和腈基的离子液体,成相能力较低,但萃取率分别提高了11.57%和34.26%。 当含腈基的离子液体浓度和磷酸钾浓度分别为5.00%和39.55%时,离子液体双水相体系对钯(Ⅱ)的萃取率可达到100%。 本文的研究成果为设计/选择可利用其双水相体系高效萃取钯(Ⅱ)的离子液体提供了理论基础和数据支持。  相似文献   

6.
The extraction of strontium and cesium ions from high ionic strength acid, base, and salt solutions into an organic extractant consisting of alkyl cobalt dicarbollide and polyethylene glycol (PEG) in diethylbenzene was investigated. Adding hexaethylene glycol or PEG-400 improved the strontium extraction ≥100-fold, while cesium extraction was decreased at high PEG concentrations. The extractions are rapid and selective, even in the presence of molar concentrations of sodium ion, suggesting that alkyl cobalt dicarbollide extractants are useful for the treatment of alkaline nuclear wastes. A method for the synthesis of tetra-n-hexyl(cobalt dicarbollide) is described.  相似文献   

7.
We evaluated an ionic‐liquid‐based ultrasound/microwave‐assisted extraction method for the extraction of 2,4‐dihydroxy‐7‐methoxy‐1,4‐benzoxazin‐3‐one and 6‐methoxy‐benzoxazolin‐2‐one from etiolated maize seedlings. We performed single‐factor and central composite rotatable design experiments to optimize the most important parameters influencing this technique. The best results were obtained using 1.00 M 1‐octyl‐3‐methylimidazolium bromide as the extraction solvent, a 50°C extraction temperature, a 20:1 liquid/solid ratio (mL/g), a 21 min treatment time, 590 W microwave power, and 50 W fixed ultrasonic power. We performed a comparison between ionic‐liquid‐based ultrasound/microwave‐assisted extraction and conventional homogenized extraction. Extraction yields of 2,4‐dihydroxy‐7‐methoxy‐1,4‐benzoxazin‐3‐one and 6‐methoxy‐benzoxazolin‐2‐one by the ionic‐liquid‐based ultrasound/microwave‐assisted extraction method were 1.392 ± 0.051 and 0.205 ± 0.008 mg/g, respectively, which were correspondingly 1.46‐ and 1.32‐fold higher than those obtained by conventional homogenized extraction. All the results show that the ionic‐liquid‐based ultrasound/microwave‐assisted extraction method is therefore an efficient and credible method for the extraction of 2,4‐dihydroxy‐7‐methoxy‐1,4‐benzoxazin‐3‐one and 6‐methoxy‐benzoxazolin‐2‐one from maize seedlings.  相似文献   

8.
A series of novel tetramethylguanidinium ionic liquids and hexaalkylguanidinium ionic liquids have been synthesized based on 1,1,3,3‐tetramethylguanidine. The structures of the ionic liquids were confirmed by 1H NMR spectroscopy and mass spectrometry. A green guanidinium ionic liquid based microwave‐assisted extraction method has been developed with these guanidinium ionic liquids for the effective extraction of Praeruptorin A from Radix peucedani. After extraction, reversed‐phase high‐performance liquid chromatography with UV detection was employed for the analysis of Praeruptorin A. Several significant operating parameters were systematically optimized by single‐factor and L9 (34) orthogonal array experiments. The amount of Praeruptorin A extracted by [1,1,3,3‐tetramethylguanidine]CH2CH(OH)COOH is the highest, reaching 11.05 ± 0.13 mg/g. Guanidinium ionic liquid based microwave‐assisted extraction presents unique advantages in Praeruptorin A extraction compared with guanidinium ionic liquid based maceration extraction, guanidinium ionic liquid based heat reflux extraction and guanidinium ionic liquid based ultrasound‐assisted extraction. The precision, stability, and repeatability of the process were investigated. The mechanisms of guanidinium ionic liquid based microwave‐assisted extraction were researched by scanning electron microscopy and IR spectroscopy. All the results show that guanidinium ionic liquid based microwave‐assisted extraction has a huge potential in the extraction of bioactive compounds from complex samples.  相似文献   

9.
《Analytical letters》2012,45(5):863-877
Abstract

This paper describes a highly sensitive and selective extraction spectrophotometric method for determination of trace germanium in natural water with new a chromogenic reagent methybenzeneazosalicylfluorone abbreviated as MBASF, in which a typical room temperature ionic liquid, 1‐butyl‐3‐methylimidazolium hexafluorophosphate abbreviated as [C4mim][PF6] was used as novel medium for liquid/liquid extraction of germanium(IV). In the presence of TritonX‐100, MBASF reacted with germanium(IV) to form a red complex rapidly, the complex was then extracted into the [C4mim][PF6] phase, the absorbance of the complex in ionic liquid at 496 nm was recorded and used to determine trace germanium(IV). The apparent molar absorptivity of the complex and the detection limit for the real sample were found to be 3.12×106 L mol?1 cm?1 and 0.2 ng mL?1, respectively. The absorbance of the complex at 496 nm increases linearly with the concentration up to 4 µg of germanium (IV) in 250 mL of aqueous solution. The interference study show the determination of germanium is free from the interference of almost all positive and negative ions found in the natural water samples. The determination of germanium in natural water was carried out by the present method and electrothermal atomic absorption spectrometry (AAS). The results were satisfactorily comparable so that the applicability of the proposed method was confirmed using the real samples. Moreover, the extraction mechanism with the ionic liquid system was also investigated. We think the extraction performance of the ionic liquid system is a combination of ion‐pairing effect between imidazolium cation and basic solute in the aqueous phase with the dissolution of polar molecule in ionic liquid phase. A wise choice of the appropriate combination of anion with imidazolium cation hydrophobicity allows playing with solute selectivity.  相似文献   

10.
The circularly polarized luminescence (CPL) of chiral disubstituted liquid‐crystalline polyacetylene (di‐LCPA) can be dynamically switched and amplified from left‐ to right‐handed CPL and vice versa through the selective transmission of CPL across a thermotropic chiral nematic liquid crystal (N*‐LC) phase. By combining a chiral di‐LCPA CPL‐emitting film with an N*‐LC cell and tuning the selective reflection band of the N*‐LC phase to coincide with the CPL emission band, a CPL‐switchable cell was constructed. The phase change induced by the thermotropic N*‐LC cell by varying the temperature leads to a change in the selective transmission of CPL, which enables the dynamic switching and amplification of CPL. It is anticipated that CPL‐switchable devices might find applications in switchable low‐threshold lasers and optical memory devices.  相似文献   

11.
芦丁在离子液体双水相中分配性能   总被引:2,自引:1,他引:1  
建立了室温离子液体四氟硼酸1-丁基-3-甲基咪唑([Bmim]BF4)和NaH2PO4组成的双水相萃取体系并用于对芦丁的萃取分离研究。考察了离子液体用量、芦丁的浓度、盐的加入量、溶液酸度和加入其它物质对芦丁在两相中分配的影响。结果表明,离子液在1.0~2.5 mL,磷酸二氢钠加入量在1.0~2.0 g,加入卢丁溶液0.5~2.5 mL,酸度在pH值为2~7范围,卢丁在离子液体双水相体系中有较高的萃取率(E%>90)。除阳离子表面活性剂外,其余大部分物质不影响相比和卢丁的测定。离子液相中卢丁的最大吸收波长为358 nm,与乙醇水溶液中比较,最大吸收波长发生紫移,表明离子液与卢丁发生了作用。利用离子液体双水相体系,测定了银杏叶中卢丁的含量。  相似文献   

12.
A novel two‐step extraction technique combining ionic‐liquid‐based dispersive liquid–liquid microextraction with magnetic solid‐phase extraction was developed for the preconcentration and separation of aflatoxins in animal feedstuffs before high‐performance liquid chromatography coupled with fluorescence detection. In this work, ionic liquid 1‐octyl‐3‐methylimidazolium hexafluorophosphate was used as the extractant in dispersive liquid–liquid microextraction, and hydrophobic pelargonic acid modified Fe3O4 magnetic nanoparticles as an efficient adsorbent were applied to retrieve the aflatoxins‐containing ionic liquid. Notably, the target of magnetic nanoparticles was the ionic liquid rather than the aflatoxins. Because of the rapid mass transfer associated with the dispersive liquid–liquid microextraction and magnetic solid phase steps, fast extraction could be achieved. The main parameters affecting the extraction recoveries of aflatoxins were investigated and optimized. Under the optimum conditions, vortexing at 2500 rpm for 1 min in the dispersive liquid–liquid microextraction and magnetic solid‐phase extraction and then desorption by sonication for 2 min with acetonitrile as eluent. The recoveries were 90.3–103.7% with relative standard deviations of 3.2–6.4%. Good linearity was observed with correlation coefficients ranged from 0.9986 to 0.9995. The detection limits were 0.632, 0.087, 0.422 and 0.146 ng/mL for aflatoxins B1, B2, G1, and G2, respectively. The results were also compared with the pretreatment method carried out by conventional immunoaffinity columns.  相似文献   

13.
A vortex‐assisted liquid–liquid microextraction method was developed for the chromatographic determination of strontium in aqueous samples. In the method, strontium was complexed with 4′,4″(5″)‐di‐(tert‐butylcyclohexano)‐18‐crown‐6 in the presence of tetraphenylborate as the counter anion, which increased the hydrophobicity of the ion‐association complex, resulting in its improved extraction into 1‐octanol. Strontium from the organic phase was stripped with nitric acid back to aqueous solution and determined by ion chromatography. The optimum microextraction conditions were as follows: 2.0 mL aqueous samples with 3 mM tetraphenylborate; 150 μL of 1‐octanol as the extractant phase with 10 mM DtBuCH18C6; vortex extraction time for 10 s; centrifugation at 6000 rpm for 4 min; stripping by 0.1 M nitric acid. Under the optimum conditions, the detection limit for strontium was 0.005 mg/L. The calibration curves showed good linearity over the range between 0.01 and 2.5 mg/L. Intra‐ and interday precisions of the present method were satisfactory with relative standard deviations of 1.7 and 2.1%, respectively.  相似文献   

14.
Labeling is critical for the detection, quantitation, and structural identification of saccharides. However, conventional liquid‐phase labeling suffers from apparent disadvantages, such as time‐consuming, the presence of excessive labeling reagent, and high applicable saccharide concentration. A solid‐phase approach is presented for highly efficient labeling of saccharides, using boronic acid functionalized mesoporous silica nanoparticles (MSNs) as a selective extraction sorbent and nanoscale reactor. The solid‐phase labeling approach exhibited several significant advantages, including: much faster reaction speed (taking only 2 min), high product purity, and much lower applicable saccharide concentration (four orders of magnitude lower than that of liquid‐phase labeling). Thus, this labeling approach opens up new avenues to the facile and efficient labeling of saccharides.  相似文献   

15.
Poly(ionic liquid)‐bonded magnetic nanospheres were easily synthesized and applied to the pretreatment and determination of phenolic compounds in water samples, which have detrimental effects on water quality and the health of living beings. The high affinity of poly(ionic liquid)s toward the target compounds as well as the magnetic behavior of Fe3O4 were combined in this material to provide an efficient and simple magnetic solid‐phase extraction approach. The adsorption behavior of the poly(ionic liquid)‐bonded magnetic nanospheres was examined to optimize the synthesis. Different parameters affecting the magnetic solid‐phase extraction of phenolic compounds were assessed in terms of adsorption and recovery. Under the optimal conditions, the proposed method showed excellent detection sensitivity with limits of detection in the range of 0.3–0.8 ng/mL and precision in the range of 1.2–3.3%. This method was also applied successfully to the analysis of real water samples; good spiked recoveries over the range of 82.5–99.2% were obtained.  相似文献   

16.
A dispersive liquid–liquid microextraction method using a lighter‐than‐water phosphonium‐based ionic liquid for the extraction of 16 polycyclic aromatic hydrocarbons from water samples has been developed. The extracted compounds were analyzed by liquid chromatography coupled to fluorescence/diode array detectors. The effects of several experimental parameters on the extraction efficiency, such as type and volume of ionic liquid and disperser solvent, type and concentration of salt in the aqueous phase and extraction time, were investigated and optimized. Three phosphonium‐based ionic liquids were assayed, obtaining larger extraction efficiencies when trihexyl‐(tetradecyl)phosphonium bromide was used. The optimized methodology requires a few microliters of a lighter‐than‐water phosphonium‐based ionic liquid, which allows an easy separation of the extraction solvent phase. The obtained limits of detection were between 0.02 and 0.56 μg/L, enrichment factors between 109 and 228, recoveries between 60 and 108%, trueness between 0.4 and 9.9% and reproducibility values between 3 and 12% were obtained. These figures of merit combined with the simplicity, rapidity and low cost of the analytical methodology indicate that this is a viable and convenient alternative to the methods reported in the literature. The developed method was used to analyze polycyclic aromatic hydrocarbons in river water samples.  相似文献   

17.
We present new results on the liquid–liquid extraction of uranium (VI) from a nitric acid aqueous phase into a tri‐n‐butyl phosphate/1‐butyl‐3‐methylimidazolium bis(trifluoromethylsulfonyl)imide (TBP/[C4mim][Tf2N]) phase. The individual solubilities of the ionic‐liquid ions in the upper part of the biphasic system are measured over the whole acidic range and as a function of the TBP concentration. New insights into the extraction mechanism are obtained through the in situ characterization of the extracted uranyl complexes by coupling UV/Vis and extended X‐ray absorption fine structure (EXAFS) spectroscopy. We propose a chemical model to explain uranium (VI) extraction that describes the data through a fit of the uranyl distribution ratio DU. In this model, at low acid concentrations uranium (VI) is extracted as the cationic complex [UO2(TBP)2]2+, by an exchange with one proton and one C4mim+. At high acid concentrations, the extraction proceeds through a cationic exchange between [UO2(NO3)(HNO3)(TBP)2]+ and one C4mim+. As a consequence of this mechanism, the variation of DU as a function of TBP concentration depends on the C4mim+ concentration in the aqueous phase. This explains why noninteger values are often derived by analysis of DU versus [TBP] plots to determine the number of TBP molecules involved in the extraction of uranyl in an ionic‐liquid phase.  相似文献   

18.
Benzophenone-3 (BZ3), one of the compounds most commonly used as UV filter in cosmetic products, can be absorbed through the skin into the human body, since it can be found at trace levels in urine from users of cosmetic products that contain BZ3. Moreover, different undesirable effects have been attributed to this compound. Thus, sensitive analytical methods to monitor urinary excretion of this compound should be developed. This paper presents a selective and sensitive methodology for BZ3 determination at ultratrace levels in human urine samples. The methodology is based on a novel microextraction technique, known as single-drop microextraction (SDME). An ionic liquid (IL) has been used as extractant phase instead of an organic solvent. After the microextraction process, the extractant phase was injected into a liquid chromatography system. The variables of interest in the SDME process were optimized using a multivariate optimization approach. A Plackett-Burman design for screening and a circumscribed central composite design for optimizing the significant variables were applied. Ionic strength, extraction time, stirring speed, pH, ionic liquid type, drop volume and sample volume were the variables studied. The optimum experimental conditions found were: sodium chloride concentration, 13% (w/v); extraction time, 25 min; stirring speed, 900 rpm; pH, 2; ionic liquid type, 1-hexyl-3-methylimidazolium hexafluorophosphate ([C(6)MIM][PF(6)]); drop volume, 5 microL; and sample volume, 10 mL. The proposed method requires a standard addition calibration approach, and it has been successfully employed to determine free BZ3 in urine samples coming from human volunteers who applied a sunscreen cosmetic containing this UV filter. The limit of detection was in the order of 1.3 ng mL(-1) and repeatability of the method, expressed as relative standard deviation, was 6% (n=8).  相似文献   

19.
Cofactors such as coenzyme A and its derivatives acetyl‐coenzyme A and malonyl‐coenzyme A are involved in many metabolic pathways. Due to trace level concentrations in biological samples and the high reactivity of cofactors, a fast, sensitive, and selective method for quantification is mandatory. In this study, online solid‐phase extraction was coupled successfully to hydrophilic interaction liquid chromatography with tandem mass spectrometry for isolation of analytes in complex matrix and quantification by external calibration. Online solid‐phase extraction was carried out by application of a weak anion‐exchange column, whereas hydrophilic interaction liquid chromatography separation was performed on an amide modified stationary phase. Sample preparation of the extracts before the analysis was reduced to a centrifugation and dilution step. Moreover, the applied online solid‐phase extraction significantly reduced matrix effects and increased the signal‐to‐noise ratio. The limit of detection and the limit of quantification were in the lower nanomolar range. Finally, the applicability of this method was demonstrated on MCF‐7 breast cancer cell cultures, a commonly used model system, where acetyl‐coenzyme A and malonyl‐coenzyme A were determined using standard addition procedure in concentrations of 1.98 μM and 41 nM, respectively.  相似文献   

20.
An orthogonal two‐dimensional solid‐phase extraction strategy was established for the selective enrichment of three aminoglycosides including spectinomycin, streptomycin, and dihydrostreptomycin in milk. A reversed‐phase liquid chromatography material (C18) and a weak cation‐exchange material (TGA) were integrated in a single solid‐phase extraction cartridge. The feasibility of two‐dimensional clean‐up procedure that experienced two‐step adsorption, two‐step rinsing, and two‐step elution was systematically investigated. Based on the orthogonality of reversed‐phase and weak cation‐exchange procedures, the two‐dimensional solid‐phase extraction strategy could minimize the interference from the hydrophobic matrix existing in traditional reversed‐phase solid‐phase extraction. In addition, high ionic strength in the extracts could be effectively removed before the second dimension of weak cation‐exchange solid‐phase extraction. Combined with liquid chromatography and tandem mass spectrometry, the optimized procedure was validated according to the European Union Commission directive 2002/657/EC. A good performance was achieved in terms of linearity, recovery, precision, decision limit, and detection capability in milk. Finally, the optimized two‐dimensional clean‐up procedure incorporated with liquid chromatography and tandem mass spectrometry was successfully applied to the rapid monitoring of aminoglycoside residues in milk.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号