首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
On-line coupled size exclusion chromatography-pyrolysis gas chromatography mass spectrometry (SEC-Py-GC-MS) is studied as a novel tool for the characterization of complex polymer samples. An automated system for on-line SEC-Py-GC-MS allowing transfer of multiple fractions was developed based on stop-flow operation of the SEC dimension, syringe-based transfer of the SEC fraction to the GC instrument and solvent elimination with subsequent pyrolysis in a programmed temperature vaporization (PTV) injector. After optimization the system was applied to the characterization of a complex terpolymer composed of very similar monomers. The use of the system for combined pyrolysis and additive analyses in polycarbonate was also demonstrated. Results obtained with the new method indicate the interesting potentials of the method for detailed characterization of polymeric materials.  相似文献   

2.
Polar-bonded stationary phases (CN-silica and Diol-silica) are used with nonaqueous eluents in adsorption mode or with aqueous eluents in partition mode. This enables the application of these systems in two-dimensional separations because of the different selectivity and application to the separation of closely related compounds of similar physicochemical properties and retention behaviour. Similarly, multiphase plates, connected with C18 strips and silica layers, are used with aqueous and nonaqueous eluents. Such layers were applied for the separation of selected coumarins. Thus, differences in separation selectivity are applied for the separation of coumarin fractions from plant extracts of the Apiaceae family by two-dimensional thin-layer chromatography.  相似文献   

3.
Separation of polar compounds on polar stationary phases with partly aqueous eluents is by no means a new separation mode in LC. The first HPLC applications were published more than 30 years ago, and were for a long time mostly confined to carbohydrate analysis. In the early 1990s new phases started to emerge, and the practice was given a name, hydrophilic interaction chromatography (HILIC). Although the use of this separation mode has been relatively limited, we have seen a sudden increase in popularity over the last few years, promoted by the need to analyze polar compounds in increasingly complex mixtures. Another reason for the increase in popularity is the widespread use of MS coupled to LC. The partly aqueous eluents high in ACN with a limited need of adding salt is almost ideal for ESI. The applications now encompass most categories of polar compounds, charged as well as uncharged, although HILIC is particularly well suited for solutes lacking charge where coulombic interactions cannot be used to mediate retention. The review attempts to summarize the ongoing discussion on the separation mechanism and gives an overview of the stationary phases used and the applications addressed with this separation mode in LC.  相似文献   

4.
AA-AM-AN三元共聚物的合成及其溶液性能的研究   总被引:3,自引:0,他引:3  
采用自由基水溶液共聚法制备了水溶性丙烯酸-丙烯酰胺-丙烯腈共聚物。对聚合反应温度、引发剂用量、尿素用量、聚合物浓度、电解质浓度、剪切速率、温度等因素对聚合物溶液性能的影响进行了研究。结果表明,合成的水溶性聚合物具有良好的增稠作用及耐温抗盐抗剪切等性能。  相似文献   

5.
The elution of ketones through ion-exchange resins with aqueous solutions of acetic acid or the lower alcohols as eluents has been studied. A mixture of seven ketones, the highest being undecanone-2, was separated by this technique. The elution of ketones with aqueous solutions of a salting-in salt was also studied.  相似文献   

6.
Selected alkaloids are chromatographed on cyanopropyl-silica thin layers using various nonaqueous and aqueous eluents. Because of the strong retention of these basic compounds, nonaqueous eluents containing medium polar diluents, strongly polar modifiers, and silanol blockers (ammonia or diethylamine) are required for separation. Likewise, aqueous eluents containing modifiers (acetonitrile, methanol, and tetrahydrofuran), buffered aqueous solutions at pH 2-8, ion-pair reagents [octane sulfonic acid sodium salt, sodium dodecyl sulphate, and bis-(2-ethylhexyl)phosphoric acid], or silanol blockers (ammonia, tetrabutyl ammonium chloride, and diethyl amine) are investigated. The separation selectivity as well as spot symmetry and efficiency system in the applied eluent systems are analyzed. The most selective and efficient systems are used in two-dimensional separations of isoquinoline alkaloids' mixture and the plant extracts Chelidonium majus, Fumaria officinalis, and Glaucium flavum. Two-dimensional thin-layer chromatography on cyanopropyl layer with diode array detection densitometry enables the separation and identification of some alkaloids in plant extracts.  相似文献   

7.
Poly(vinyl alcohol) (PVOH) samples may contain several heterogeneities requiring the development of chromatographic techniques for characterization. Size exclusion separations have been carried out using a number of aqueous eluents, incorporating electrolyte, or electrolyte/organic modifier, or surfactant. The most favourable molecular size separation was obtained using 0.25% w/v sodium lauryl sulfate as eluent. Reasonable values for molecular weights of PVOH samples have been determined. Compositional distributions in copolymer systems can be assessed using high-performance liquid chromatography employing a reversed-phase separation mechanism. For poly(vinyl alcohol), gradient elution with water/tetrahydrofuran (THF) with a wide pore polystyrene-based packing produced separations dependent on degree of hydrolysis and sequence length distribution. The elution results were verified with a column packed with non-porous beads. Partially hydrolysed PVOH samples appeared to have a broad distribution of composition.  相似文献   

8.
Li Y  Feng Y  Chen T  Zhang H 《Journal of chromatography. A》2011,1218(35):5987-5994
An imidazoline was prepared by solvent-free microwave-assisted organic synthesis and immobilized on porous silica particles by polymerization. The resulting material was composed of both hydrophobic alkyl ester chains and hydrophilic imidazoline rings, which gave it both hydrophilic interaction and reversed-phase characteristics. The titration curve suggests that the new material has buffering capacity and acquires increasing positive charge over the pH range 9-4, and is "zwitterionic" in the upper part of this pH range. Through investigating the effect of column temperature, the water content, pH and ion strength of mobile phase on the retention time of polar compounds in highly organic eluents, it was found that the new material could be used as a hydrophilic interaction liquid chromatography (HILIC) stationary phase which involved a complex retention process consisting of partitioning, surface adsorption and electrostatic interactions. In addition, the retention behavior of aromatic compounds in different mobile phase conditions was also studied, which showed the new material mainly exhibited a partitioning mechanism in the reversed-phase liquid chromatography (RPLC) mode. The separation of six water-soluble vitamins and five aromatic compounds were achieved by using the new material in the HILIC and RPLC modes, respectively.  相似文献   

9.
A new method of chromatography is proposed, utilizing a thermo-responsive polymer carrying an amino acid ester residue for the stationary phase of high-performance liquid chromatography (HPLC). We have been investigating the new concept of chromatography, a temperature-responsive chromatography, using temperature-responsive poly(N-isopropylacrylamide) (PNIPAAm)-modified surface for HPLC with a constant aqueous media as the mobile phase. In this study, we designed and synthesized thermo-responsive poly(acryloyl-L-proline methyl ester) and its copolymer with N-isopropylacrylamide (NIPAAm). Homopolymers of acryloyl-L-proline methyl ester and copolymer were prepared by the reaction of radical telomerization. These polymers underwent a reversible phase transition from water-soluble forms into aggregates by changing the temperature, similar to PNIPAAm. The surface properties and functions of stationary phases modified with poly(acryloyl-L-proline methyl ester) were controlled by the external temperature. In the chromatographic system, we separated steroids and amino acids with a variety of hydrophobicities using a sole aqueous mobile phase. In contrast to a PNIPAAm-modified surface, a poly(acryloyl-L-proline methyl ester)-modified surface showed a greater affinity for hydrophobic amino acids.  相似文献   

10.
杨丙成  李宗英 《色谱》2021,39(2):130-133
电渗析器件通常定义为在电场作用下操纵离子从一种溶液穿过离子交换膜迁移到另外一种溶液的一种设备。它可以通过电解水产生氢离子或氢氧根离子,从而用于离子色谱系统的淋洗液在线制备、抑制或检测。相较于人工配制淋洗液或再生液,电渗析技术具有绿色、高效、纯度高、自动化程度高等优势。因此基于电渗析器件的离子色谱系统应用范围越来越大。该文简要评述了近几年该器件的研究进展,具体包括电致淋洗液发生器、电致膜抑制器和电渗析样品前处理器。  相似文献   

11.
水溶性增粘剂;增粘性能;协同增效作用;疏水缔合作用;剪切作用;NaCMC与甲基丙烯酰氧乙基二甲基辛基溴化铵及AM接枝共聚物的性能  相似文献   

12.
The gel permeation chromatography (GPC) of polyelectrolytes is discussed. The electrostatic exclusion is demonstrated using simple electrolytes with different eluents. The data for aqueous free salt solutions of polyelectrolytes are interpreted. The osmotic coefficient is deduced and its dependence on molecular weight and polymer concentration reported. In salt eluents, the Donnan exclusion is discussed. The universal calibration obtained with different standards in aqueous solution is shown to be valid and identical to that obtained in an organic solvent using polystyrene standards.  相似文献   

13.
Li Y  Li J  Chen T  Liu X  Zhang H 《Journal of chromatography. A》2011,1218(11):1503-1508
The mixed sulfated/methacryloyl polysaccharide derivative was prepared and successfully immobilized onto the surface of porous silica particles by polymerization. Polysaccharide derivative was calculated as 10.33% in the stationary phase prepared. The new stationary phase (PMSP) showed both hydrophilic interaction (HILIC) and per aqueous liquid chromatography (PALC) characteristics. The effects of column temperature, the water content, pH and ion strength of mobile phase on the retention time of test compounds in highly aqueous eluents were investigated to evaluate the PALC features of PMSP. The column efficiency is about 31,000 plates/m for benzoic acid in water/ACN (97/3, v/v) mobile phase at a flow rate of 1.0 mL/min. Compared with C18 column, the PMSP had shorter retention time for weak polar and non-polar compounds, but also showed stronger retention for strong polar compounds. It indicated that PALC was a suitable mode of chromatography as replacement of HILIC and complementarity of reversed-phase liquid chromatography (RPLC).  相似文献   

14.
The influence of different eluents in positive and negative ion mode thermospray liquid chromatography-mass spectrometry was studied with several groups of pesticides, including carbamates, chlorotriazines, phenylureas, phenoxy acids and organophosphorus and quaternary ammonium compounds, and the corresponding degradation products. Using the positive ion mode in combination with reversed-phase eluents the base peaks generally corresponded either to [M + H]+ for the chlorotriazines and their hydroxy metabolites or to [M + NH4]+ for the carbamates, the phenylureas, the organophosphorus pesticides and their oxygen analogues. In the negative ion mode different processes such as (dissociative) electron-capture and anion attachment mechanisms occurred. Fragment ions such as [M - CONHCH3]- for the carbamates, [M - H]- for the chlorotriazines, phenylureas and chlorinated phenoxy acids and [M].-, [M - R]- (R being a methyl or ethyl group) for organophosphorus pesticides were usually formed. Depending on the eluent additive used (ammonium acetate, ammonium formate and/or chloroacetonitrile), three different adduct ions were formed: [M + CH3COO]-, [M + HCOO]- and [M + Cl]-. Normal-phase eluents with cyclohexane, n-hexane and/or dichloromethane provided more structural information and enhanced the response of several compounds. The positive ion mode was useful for the detection of chlorinated phenoxy acids and chlorophenols which could not be detected in the positive ion mode using reversed-phase systems. The base peaks generally corresponded to [M].+, [M + H]+ or [M - Cl]+. For the characterization of difenzoquat, a quaternary ammonium pesticide of which trace level analysis is troublesome, a post-column ion-pair extraction system was used. An aqueous mobile phase with a sulphonate-type counter ion was applied and an extraction solvent containing cyclohexane-dichloromethane-n-butanol (45:45:10) was used in thermospray liquid chromatography-mass spectrometry. Illustrative examples of the determination of residue levels of pesticides in soil matrices are shown.  相似文献   

15.
Summary By modification of a given conventional high pressure liquid chromatography (HPLC) unit a microbore system was built up useful for separations of S-containing anions in small aqueous samples. The sample volume could be lowered down to 0.5 l. Mixtures of a lipophilic reagent (TPAOH or TBAOH) with boric acid and acetonitrile were used as eluents.  相似文献   

16.
Temperature gradient interaction chromatography (TGIC) is a powerful technique for molecular weight fractionation of polymers, in which the interaction strength is controlled by varying the column temperature. In the present paper, the effects of the sign of the temperature dependence of the retention and the direction of the temperature gradient (raising or lowering) on TGIC in the normal-phase mode were studied for the molecular weight fractionation of polystyrene samples in organic mobile phases. It was found that a positive temperature gradient was effective in the system consisting of amino-modified silica (NH(2)) column and the eluent mixture of tetrahydrofuran and n-hexane where retention decreased with increasing temperature. A negative temperature gradient was effective for the systems consisting of a bare-silica column//chloroform/n-hexane and NH(2)-column//chloroform/n-hexane, where retention increased with increasing temperature. Increasing retention with increasing temperature has been found, so far, only for a water-soluble polymer (PEO) in an aqueous mobile phase in RP-TGIC.  相似文献   

17.
 The synthesis, viscometric, and fluorescence properties of a water-soluble zwitterionic sulfobetaine copolymer, poly(ADMMAPS)/NA, are reported. When fluorescent hydrophobes (naphthyl group) are incorporated into the zwitterionic copolymer, the photophysical response may effectively probe solution behavior on the microscopic level. Experimental results indicate that I E/I M steadily increases with increases in polymer concentration. I E/I M in aqueous solution is greater than that in aqueous potassium chloride solution. Dynamic light scattering (QELS) measurements show that hydrodynamic diameters of the naphthalene-labeled zwitterionic sulfobetaine copolymer increase with an increasing salt concentration. Viscosity studies reveal that the polymer coil expanded as more salt is added. In fluorescence quenching study, the reduction in the quenching efficiency of Tl+ with salt addition can arise from enhanced compartmentalization of naphthalene labels as added electrolyte enhances intrapolymer micellization. The intrapolymer micelle is easily formed, indicating that the thallium ion has difficulty reacting with bound naphthalenes located in the polymer coil. The naphthalene-labeled zwitterionic sulfobetaine copolymer is depicted as a compacted polymer coil conformation in deionized water because of intra-and inter-associations. Consequently, salt addition breaks up the associations and enhances the intrapolymer micellization. The microscopic and macroscopic behaviors of zwitterionic sulfobetaine copolymer differ a lot from those of the corresponding cationic copolymer. Received: 4 February 1997 Accepted: 1 May 1997  相似文献   

18.
Two-dimensional reversed-phase liquid chromatography/hydrophilic interaction liquid chromatography (2D-RPLC/HILIC) system was successfully applied for comprehensive characterization of steviol glycosides from Stevia rebaudiana. The experiments were performed in offline mode using an XCharge C18 column in first dimension and an XAmide column in second dimension. In first dimension, preliminary separation of Stevia aqueous extract was accomplished and 30 fractions were collected. Then fractions 1-20 were selected for further purification and 13 compounds with high purity were obtained in second dimension. Comprehensive characterization of these compounds was completed by determination of their retention time, accurate molecular weight, diagnostic fragmentation ions, and nuclear magnetic resonance spectroscopy. As a result, all nine known steviol glycosides, as well as other four steviol glycosides were fully purified. The result demonstrated that this procedure is an effective approach for the preparative separation and comprehensive characterization of steviol glycosides in Stevia. This 2D-RPLC/HILIC method will be a promising tool for the purification of low-abundance compounds from natural products.  相似文献   

19.
Extensive research has been carried out on functional polymers which are currently playing important roles in various fields such as medicine and engineering. Such functional polymers which respond to various kinds of stimuli are termed 'intelligent materials'. Poly(N-isopropylacrylamide) (PNIPAAm), a temperature-responsive polymer, was utilized as a chromatography column matrix modifier for a novel chromatographic approach in which only aqueous media are used as a mobile phase. The ability of the developed temperature-responsive chromatography system to separate solutes without using an organic solvent is advantageous from the point of view of maintaining the structure and activity of bioactive compounds. Recently, we designed and synthesized a new pH- and temperature-responsive copolymer as a representative of such environment-responsive polymers and grafted it onto aminopropyl silica beads. The products were evaluated as HPLC packing materials for separation systems based on a new concept, according to which the properties of the stationary phase surface are altered by external stimuli such as pH and temperature. This chromatography system utilizing the PNIPAAm copolymer is very useful for the separation of bioactive substances, such as proteins and peptides, because separation in the aqueous mobile phase is controlled solely by changing the temperature. This analytical system reduces organic waste because no organic solvent is used to separate the solutes and can therefore be classified as environmentally friendly. Future medical and pharmaceutical applications are expected.  相似文献   

20.
Temperature-responsive chromatography for the separation of biomolecules   总被引:2,自引:0,他引:2  
Temperature-responsive chromatography for the separation of biomolecules utilizing poly(N-isopropylacrylamide) (PNIPAAm) and its copolymer-modified stationary phase is performed with an aqueous mobile phase without using organic solvent. The surface properties and function of the stationary phase are controlled by external temperature changes without changing the mobile-phase composition. This analytical system is based on nonspecific adsorption by the reversible transition of a hydrophilic-hydrophobic PNIPAAm-grafted surface. The driving force for retention is hydrophobic interaction between the solute molecules and the hydrophobized polymer chains on the stationary phase surface. The separation of the biomolecules, such as nucleotides and proteins was achieved by a dual temperature- and pH-responsive chromatography system. The electrostatic and hydrophobic interactions could be modulated simultaneously with the temperature in an aqueous mobile phase, thus the separation system would have potential applications in the separation of biomolecules. Additionally, chromatographic matrices prepared by a surface-initiated atom transfer radical polymerization (ATRP) exhibit a strong interaction with analytes, because the polymerization procedure forms a densely packed polymer, called a polymer brush, on the surfaces. The copolymer brush grafted surfaces prepared by ATRP was an effective tool for separating basic biomolecules by modulating the electrostatic and hydrophobic interactions. Applications of thermally responsive columns for the separations of biomolecules are reviewed here.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号