首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 29 毫秒
1.
Three stability indicating assay methods are developed for the determination of norfloxacin (Nor) in the presence of its decarboxylated degradation product and in mixture with tinidazole (Tnd). The proposed methods are reversed phase ion pair liquid chromatography (LC), thin layer densitometry (TLC) and second derivative ratio spectra zero crossing spectrophotometry ((2)DD). Chromatographic separation was achieved on mu-Bondapack C18 column 5 microm (300 mm x 3.9 mm, I.D.) and precoated silica gel TLC stationary phases for LC and TLC methods, respectively. Mobile phases consisting of phosphate buffer pH 3.2 : methanol (3 : 1, v/v) containing 0.005 M pentane sulfonic acid sodium salt and isopropanol : butanol : concentrated ammonia : water (25 : 50 : 5 : 25, v/v/v/v) were used for resolution of Nor and Tnd by both techniques, respectively. Detection was carried at 280 nm. In the ratio spectra method, detection of Nor was carried at 282 nm. Linearity, accuracy and precision were found to be acceptable over concentration ranges of 20-225 microg/ml, 0.8-4 microg/spot and 1-7 microg/ml for Nor by LC, TLC and (2)DD methods and over concentration ranges of 37.5-375 microg/ml and 4.8-20 microg/spot for Tnd by LC and TLC methods respectively. The suggested methods were successfully applied for the determination of both drugs in bulk powder, laboratory prepared mixtures and in commercial samples. Statistical comparison between the results obtained by the proposed and the reference methods was carried out using Student t-test, F ratio and one way ANOVA.  相似文献   

2.
New, simple, rapid, and precise reversed-phase high-performance liquid chromatographic (LC) methods were developed for the simultaneous determination of chlorzoxazone (CH) and ketoprofen (KT) in binary mixtures and in ternary mixtures containing the CH degradation product, 2-amino-4-chlorophenol (CD). The analytes were separated by LC on a Lichrosphere 60 C18 column (250 x 4 mm, 5 microm). The mobile phases, methanol-water (40:60, v/v) at 1 mL/min and methanol-0.05% phosphoric acid (60:40, v/v, pH 2.81) at 1.5 mL/min, satisfactorily resolved the binary and ternary mixtures, respectively. The UV detector was operated at 280 nm for the determination of CH and at 254 nm for the determination of KT and CD. Linearity, accuracy, and precision were found to be acceptable over the concentration ranges of 20-240 and 5-60 microg/mL for CH and KT, respectively, in the binary mixtures and 50-300, 10-60, and 20-160 microg/mL for CH, KT, and CD, respectively, in the ternary mixtures. The optimized methods proved to be specific, robust, and accurate for the quality control of CH and KT in pharmaceutical preparations.  相似文献   

3.
A simple, precise and rapid RP-HPLC method was developed for the determination of repaglinide in pharmaceutical dosage forms. The method was carried out on a Shim-pack, RP-C18 column using a mixture of methanol: 0.1% v/v triethylamine (pH adjusted to 7 with orthophosphoric acid) and detection was done at 235 nm using nimesulide as internal standard. The linearity range was 0.1 to 0.5 microg/ml. The intra-day and inter-day precision were in the range of 0.48 to 1.01 and 0.15 to 1.15, respectively.  相似文献   

4.
Thin-layer chromatography, first derivative, ratio spectra derivative spectrophotometry and Vierordt's method have been developed for the simultaneous determination of paracetamol and drotaverine HCl. TLC densitometric method depends on the difference in Rf values using ethyl acetate:methanol:ammonia (100:1:5 v/v/v) as a mobile phase. The spots of the two drugs were scanned at 249 and 308 nm over concentration ranges of 60-1200 microg/ml and 20-400 microg/ml with mean percentage recovery 100.11%+/-1.91 and 100.15%+/-1.87, respectively. The first derivative spectrophotometric method deals with the measurements at zero-crossing points 259 and 325 nm with mean percentage recovery 99.25%+/-1.08 and 99.45%+/-1.14, respectively. The ratio spectra first derivative technique was used at 246 and 305 nm with mean percentage recovery 99.75%+/-1.93 and 99.08%+/-1.22, respectively. Beer's law for first derivative and ratio spectra derivative methods was obeyed in the concentration range 0.8-12.8 and 0.4-6.4 microg/ml of paracetamol and drotaverine HCl, respectively. Vierordt's method was applied to over come the overlapping of paracetamol and drotaverine HCl in zero-order spectra in concentration range 2-26 and 2-40 microg/ml respectively. The suggested methods were successfully applied for the analysis of the two drugs in laboratory prepared mixtures and their pharmaceutical formulation. The validity of the methods was assessed by applying the standard addition technique. The obtained results were statistically agreed with those obtained by the reported method.  相似文献   

5.
ABSTRACT: A simple reversed phase high performance liquid chromatographic method with diode array detector (HPLC-DAD) has been developed and subsequently validated for the determination of fexofenadine hydrochloride (FEX) and its related compounds; keto fexofenadine (Impurity A), meta isomer of fexofenadine (Impurity B), methyl ester of fexofenadine (Impurity C) in addition to the methyl ester of ketofexofenadine (Impurity D). The separation was based on the use of a Hypersil BDS C-18 analytical column (250 × 4.6 mm, i.d., 5 μm). The mobile phase consisted of a mixture of phosphate buffer containing 0.1 gm% of 1-octane sulphonic acid sodium salt monohydrate and 1% (v/v) of triethylamine, pH 2.7 and methanol (60:40, v/v). The separation was carried out at ambient temperature with a flow rate of 1.5 ml/min. Quantitation was achieved with UV detection at 215 nm using lisinopril as internal standard, with linear calibration curves at concentration ranges 0.1-50 μg/ml for FEX and its related compounds. The optimized conditions were used to develop a stability-indicating HPLC-DAD method for the quantitative determination of FEX and its related compounds in tablet dosage forms. The drugs were subjected to oxidation, hydrolysis, photolysis and heat to apply stress conditions. Complete separation was achieved for the parent compounds and all degradation products. The method was validated according to ICH guidelines in terms of accuracy, precision, robustness, limits of detection and quantitation and other aspects of analytical validation.  相似文献   

6.
A well‐known analgesic (paracetamol, PAR) and skeletal muscle relaxant [dantrolene sodium (DNS)] have been analyzed without interference from their toxic impurities and degradation products. The studied PAR impurities are the genotoxic and nephrotoxic p‐amino phenol (PAP) and the hepatotoxic and nephrotoxic chloroacetanilide, while 5‐(4‐nitrophenyl)‐2‐furaldehyde is reported to be a mutagenic and carcinogenic degradation product of DNS. The five studied components were determined and quantified by TLC–densitometric and RP‐HPLC methods. TLC–densitometry (method 1) used TLC silica gel and chloroform–ethyl acetate–acetic acid–triethylamine (7:3:0.5:0.05, by volume) as the mobile phase with UV scanning at 230 nm, while RP‐HPLC (method 2) was based on separation on a C18 column using methanol–water (55:45, v/v pH 3 with aqueous formic acid) as mobile phase at 1 mL/min and detection at 230 nm. The developed methods were used for determination and quantification of the five studied components in different laboratory‐prepared mixtures. The were also applied for analysis of Dantrelax® compound capsules where no interference among the studied components with each other or from excipients was observed. The methods were validated as per International Conference on Harmonization guidelines, and they compared favorably with the reported ones.  相似文献   

7.
ABSTRACT: BACKGROUND: A simple, specific, and fast stability indicating reverse phase liquid chromatographic method was established for instantaneous determination of moxifloxacin and prednisolone in bulk drugs and pharmaceutical formulations. RESULTS: Optimum chromatographic separations among the moxifloxacin, prednisolone and stressinduced degradation products were achieved within 10 minutes by use of BDS Hypersil C8 column (250 X 4.6 mm, 5 mum) as stationary phase with mobile phase consisted of a mixture of phosphate buffer (18 mM) containing 0.1% (v/v) triethylamine, at pH 2.8 (adjusted with dilute phosphoric acid) and methanol (38:62 v/v) at a flow rate of 1.5 mL min-1. Detection was performed at 254 nm using diode array detector. The method was validated in accordance with ICH guidelines. Response was a linear function of concentrations over the range of 20-80 mug mL-1 for moxifloxacin (r2 [greater than or equal to] 0.998) and 40-160 mug mL-1 for prednisolone (r2 [greater than or equal to] 0.998). The method was resulted in good separation of both the analytes and degradation products with acceptable tailing and resolution. The peak purity index for both the analytes after all types of stress conditions was [greater than or equal to] 0.9999 indicated a complete separation of both the analyte peaks from degradation products. The method can therefore, be regarded as stabilityindicating. CONCLUSIONS: The developed method can be applied successfully for simultaneous determination of moxifloxacin and prednisolone in pharmaceutical formulations and their stability studies.  相似文献   

8.
Citicoline and piracetam were subjected separately to different stress conditions as recommended by the international conference on harmonization. In addition, new stability indicating thin layer chromatographic and ultra high performance liquid chromatographic methods have been developed and validated for simultaneous determination of citicoline and piracetam in presence of their degradation products. Separation on the proposed thin layer chromatographic method was carried out using a developing system containing methanol:chloroform:ammonium chloride buffer (9:1:2, v/v/v) on silica gel plates at 230 nm. On the other hand, the mobile phase in the ultra high performance liquid chromatographic method was composed of water (containing 0.1% triethylamine):ethanol (92:8, v/v). The flow rate was 1 mL/min and ultraviolet detection was at 230 nm. Moreover, results of the developed methods were statistically compared to those obtained by the reported high‐performance liquid chromatography method and no significant difference between them was found. The greenness profile of ultra high performance liquid chromatographic method was assessed and compared with those of the previously published high‐performance liquid chromatography methods, it was noticed that the proposed ultra high performance liquid chromatographic method more environmentally friendly and greener than other methods.  相似文献   

9.
Two sensitive and reproducible methods were developed and validated for the determination of ziprasidone (ZIP) in the presence of its degradation products in pure form and in pharmaceutical formulations. The fi rst method was based on reversed-phase high-performance liquid chromatography (HPLC), on a Lichrosorb RP C(18) column using water:acetonitrile:phosphoric acid (76:24:0.5 v/v/v) as the mobile phase at a fl ow rate of 1.5 mL min(-1) at ambient temperature. Quantification was achieved with UV detection at 229 nm over a concentration range of 10-500 micro g mL(-1) with mean percentage recovery of 99.71 +/- 0.55. The method retained its accuracy in presence of up to 90% of ZIP degradation products. The second method was based on TLC separation of ZIP from its degradation products followed by densitometric measurement of the intact drug spot at 247 nm. The separation was carried out on aluminium sheet of silica gel 60 F(254) using choloroform:methanol:glacial acetic acid (75:5:4.5 v/v/v) as the mobile phase, over a concentration range of 1-10 micro g per spot and mean percentage recovery of 99.26 +/- 0.39. Both methods were applied successfully to laboratory prepared mixtures and pharmaceutical capsules.  相似文献   

10.
Hegazy  Maha A.  Yehia  Ali M.  Mostafa  Azza A. 《Chromatographia》2011,74(11):839-845

Simple, sensitive, selective, precise, and stability-indicating thin-layer chromatography (TLC) and high-performance liquid chromatography (HPLC) methods for the determination of mosapride and pantoprazole in pharmaceutical tablets were developed and validated as per the International Conference on Harmonization guidelines. The TLC method employs aluminum TLC plates precoated with silica gel 60F254 as the stationary phase and ethyl acetate/methanol/toluene (4:1:2, v/v/v) as the mobile phase to give compact spots for mosapride (R f 0.73) and pantoprazole (R f 0.45) separated from their degradation products; the chromatogram was scanned at 276 nm. The HPLC method utilizes a C18 column and a mobile phase consisting of acetonitrile/methanol/20 mM ammonium acetate (4:2:4, v/v/v) at a flow rate of 1.0 mL min−1 for the separation of mosapride (t R 11.4) and pantoprazole (t R 4.4) from their degradation products. Quantitation was achieved with UV detection at 280 nm. The same HPLC method was successfully used in performing calibrations in lower concentration ranges for both drugs in human plasma using ezetimibe as internal standard. The methods were validated in terms of accuracy, precision, linearity, limits of detection, and limits of quantification. Mosapride and pantoprazole were exposed to acid hydrolysis and then analyzed by the proposed methods. As the methods could effectively separate the drugs from their degradation products, these techniques can be employed as stability-indicating methods that have been successively applied to pharmaceutical formulations without interference from the excipients. Moreover the HPLC method was successfully used in the determination of both drugs in spiked human plasma.

  相似文献   

11.
Simple, sensitive, selective, precise, and stability-indicating thin-layer chromatography (TLC) and high-performance liquid chromatography (HPLC) methods for the determination of mosapride and pantoprazole in pharmaceutical tablets were developed and validated as per the International Conference on Harmonization guidelines. The TLC method employs aluminum TLC plates precoated with silica gel 60F254 as the stationary phase and ethyl acetate/methanol/toluene (4:1:2, v/v/v) as the mobile phase to give compact spots for mosapride (R f 0.73) and pantoprazole (R f 0.45) separated from their degradation products; the chromatogram was scanned at 276 nm. The HPLC method utilizes a C18 column and a mobile phase consisting of acetonitrile/methanol/20 mM ammonium acetate (4:2:4, v/v/v) at a flow rate of 1.0 mL min?1 for the separation of mosapride (t R 11.4) and pantoprazole (t R 4.4) from their degradation products. Quantitation was achieved with UV detection at 280 nm. The same HPLC method was successfully used in performing calibrations in lower concentration ranges for both drugs in human plasma using ezetimibe as internal standard. The methods were validated in terms of accuracy, precision, linearity, limits of detection, and limits of quantification. Mosapride and pantoprazole were exposed to acid hydrolysis and then analyzed by the proposed methods. As the methods could effectively separate the drugs from their degradation products, these techniques can be employed as stability-indicating methods that have been successively applied to pharmaceutical formulations without interference from the excipients. Moreover the HPLC method was successfully used in the determination of both drugs in spiked human plasma.  相似文献   

12.
This work presents an HPLC method for the quantification of free amino acids in lyophilized protein fraction from shrimp waste hydrolysate which is obtained by acid lactic fermentation and analyzed using pre-column derivatization with 9-fluorenylmethyl-chloroformate. The amino acids were separated in a Hypersil ODS 5 microm column (250 mm x 4.6 mm) at 38 degrees C. The mobile phase was a mixture of phase A: 30 mM ammonium phosphate (pH 6.5) in 15:85 (v/v) methanol/water; phase B: 15:85 (v/v) methanol/water; and phase C: 90:10 (v/v) acetonitrile/water, with flow rate 1.2 ml/min. Fluorescence detection was used at an excitation wavelength of 270 nm and an emission wavelength of 316 nm. Method precisions for the different amino acids were between 4.4 and 7.1% (relative standard deviation, RSD); detection limits were between 23 and 72 ng/ml; and the recoveries were between 89.0 and 95.0%. The amino acid present at the highest concentration was tyrosine.  相似文献   

13.
Four methods have been developed for the simultaneous determination of phenylephrine hydrochloride and chlorpheniramine maleate without previous separation. In the first method both drugs are determined using first derivative UV spectrophotometry, with zero-crossing measurement. The second method depends on first derivative of the ratios spectra. The third method describes the use of multivariate spectrophotometric calibration for the simultaneous determination of the analyzed binary mixture where the resolution is accomplished by using partial least squares (PLS) regression analysis. In the fourth method (HPLC), a reversed-phase column and a mobile phase of methanol:water:acetonitrile (80:12:8 v/v/v/) at 0.9 ml/min flow rate have been used to separate both drugs with a UV detection at 270 nm. All the proposed methods are extensively validated. They have the advantage to be economic and time saving. All the described methods can be readily utilized for analysis of pharmaceutical formulations. The results obtained using the proposed methods are statistically analyzed and compared with some reported methods.  相似文献   

14.
A simple sensitive, selective and accurate reversed-phase high performance liquid chromatographic method was developed and validated for the quantitative determination of lansoprazole, omeprazole and pantoprazole sodium sesquishydrate in the presence of their acid-induced degradation products. The three compounds were monitored at 280 nm using Nova-Pak C(18) column and a mobile phase consisting of 0.05 M potassium dihydrogen phosphate : methanol : acetonitrile (5 : 3 : 2 v/v/v). Linearity ranges were 2-20 mug ml(-1), 2-36 mug ml(-1) and 0.5-20 mug ml(-1) for lansoprazole, omeprazole and pantoprazole, respectively. The corresponding recoveries were 100.61+/-0.84%, 100.50+/-0.80% and 99.78+/-0.88%. The minimum detection limits were 0.55, 0.54 and 0.03 mug ml(-1) for lansoprazole, omeprazole and pantoprazole, respectively. The method could be successfully applied to the determination of pure, laboratory prepared mixtures and pharmaceutical dosage forms. The results obtained were compared with the reported methods for lansoprazole and pantoprazole or the official U.S.P method for omeprazole.  相似文献   

15.
Two sensitive and selective methods were developed for the determination of some oxicams, namely, lornoxicam (LOX), tenoxicam (TEX), and meloxicam (MEX), in the presence of their alkaline degradation products. The first method is based on the thin-layer chromatographic separation of the 3 drugs from their alkaline degradation products, followed by densitometric measurement of the intact drug spots for LOX, TEX, and MEX at 380, 370, and 364 nm, respectively. The developing systems used for separation are ethyl acetate-methanol-26% ammonia (17 + 3 + 0.35, v/v/v) for LOX and TEX and chloroform-n-hexane-96.0% acetic acid (18 + 1 + 1, v/v/v) for MEX. The linear ranges were 0.25-6.0 microg/spot for LOX and TEX and 0.5-10 microg/spot for MEX, with mean recoveries of 99.80 +/- 1.32, 100.57 +/- 1.34, and 100.71 +/- 1.57%, respectively. The second method is based on the liquid chromatographic separation of the 3 drugs from their alkaline degradation products on a reversed-phase C18 column, using mobile phases of methanol-acetonitrile-acetate buffer, pH 4.6 (4.5 + 0.5 + 5.0, v/v/v) for LOX and MEX and methanol-acetonitrile-acetate buffer, pH 4.6 (1.9 + 0.1 + 3.0, v/v/v) for TEX at ambient temperature. Quantification is achieved by UV detection at 280 nm, based on peak area. The linear ranges were 0.5-20 microg/mL for LOX and TEX and 1.25-50 microg/mL for MEX, with mean recoveries of 99.81 +/- 1.01, 98.90 +/- 1.61, and 100.86 +/- 1.55%, respectively. The methods were validated according to guidelines of the International Conference on Harmonization. The developed methods were successfully applied to the determination of LOX, TEX, and MEX in bulk powder, laboratory-prepared mixtures containing different percentages of degradation products, and pharmaceutical dosage forms.  相似文献   

16.
Accurate, sensitive, and precise high performance thin layer chromatographic (HPTLC) methods were developed and validated for the determination of sumatriptan and zolmitriptan in presence of their degradation products. Sumatriptan was separated from its degradation products and analyzed on TLC silica gel 60 F254 plates using chloroform–ethyl acetate–methanol–ammonia (4:3:3:0.1, v/v) as a developing system followed by densitometric measurement of the bands at 228 nm. Zolmitriptan was determined using chloroform–ethyl acetate–methanol–ammonia (3:3:3:1, v/v) as a developing system followed by densitometric measurement at 222 nm. The methods were validated over a range of 0.5–4 μg/spot for sumatriptan and 0.5–3 μg/spot for zolmitriptan. The proposed methods were successfully applied for the determination of the studied drugs in bulk powder and in their pharmaceutical formulations.  相似文献   

17.
《Analytical letters》2012,45(9):1641-1653
Abstract

High performance thin layer chromatographic (HPTLC) and high performance liquid chromatographic (HPLC) methods were developed for the simultaneous determination of Tinidazole and Furazolidone in suspension.

In the HPTLC method the separation of Tinidazole and Furazolidone was carried out on silica gel 60F254 HPTLC glass plate using chloroform:methanol:ammonia (9:1:0.1 v/v) as a mobile phase. Rf values obtained were 0.63 and 0.79 for Furazolidone and Tinidazole respectively. Densitometric evaluation was done at 335 nm. Linearity was obtained within the concentration range 10–50 μg/ml and 3.5–17.5 μg/ml for Tinidazole and Furazolidone respectively.

The second method is based on high performance liquid chromatography on a reversed phase column (μ Bondapak C18) using a mobile phase comprised of water: acetonitrile: triethylamine (80:20:0.1 v/v) adjusted to pH = 3.0 with dil. phosphoric acid. Retention times were 5.24 and 7.82 min for Tinidazole and Furazolidone respectively at a flow rate of 1.5 ml/min. Detection was done at 335 nm. Linearity was obtained within the concentration range 30–180 μg/ml and 10.5–63 μg/ml for Tinidazole and Furazolidone resp.  相似文献   

18.
In this work, two stability‐indicating chromatographic methods have been developed and validated for determination of flecainide acetate (an antiarrhythmic drug) in the presence of its degradation products (flecainide impurities; B and D). Flecainide acetate was subjected to a stress stability study including acid, alkali, oxidative, photolytic and thermal degradation. The suggested chromatographic methods included the use of thin layer chromatography (TLC‐densitometry) and high‐performance liquid chromatography (HPLC). The TLC method employed aluminum TLC plates precoated with silica gel G.F254 as the stationary phase and methanol–ethyl acetate–33% ammonia (3:7:0.3, by volume) as the mobile phase. The chromatograms were scanned at 290 nm and visualized in daylight by the aid of iodine vapor. The developed HPLC method used a RP‐C18 column with isocratic elution. Separation was achieved using a mobile phase composed of phosphate buffer pH 3.3–acetonitrile–triethylamine (53:47:0.03, by volume) at a flow rate of 1.0 mL/min and UV detection at 292 nm. Factors affecting the efficiency of HPLC method have been studied carefully to reach the optimum conditions for separation. The developed methods were validated according to the International Conference on Harmonization guidelines and were applied for bulk powder and dosage form. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

19.
Two stability-indicating methods, namely densitometric TLC and derivative spectrophotometry for the determination of the fluoroquinolone antibacterials lomefloxacin (Lfx), moxifloxacin (Mfx), and sparfloxacin (Sfx) in the presence of their acid degrades are described. Acid degradation was adopted and the main decarboxylated product separated by TLC. Degradation products were identified confirming a previously mentioned degradation scheme. The densitometric method is based on the separation of the intact drug from its acid degradation product on silica gel G plates using different mobile phases and the spots of the intact drugs were scanned at 288, 290, and 292 nm for Lfx, Mfx, and Sfx, respectively. The derivative spectrophotometric method utilizes first derivative D(1) UV spectrophotometry with zero crossing points at 295.2 nm for Lfx, 280.4 and 303.4 nm for Mfx, and 280.8 nm for Sfx. Regression analysis of Beer's plots showed good correlation in the concentration ranges 0.2-1.2, 0.1-1.4, and 0.5-2.0 microg/spot for Lfx, Mfx, and Sfx, respectively, in the densitometric method and 2-16 microg/ml for all drugs in the derivative spectrophotometric method. The proposed methods were successfully applied for the determination of the investigated drugs in bulk powder with mean percentage accuracy ranges from 98.93 to 101.25% for the TLC method and from 98.18 to 100.35% for the D(1) method. The proposed methods were also applied for the determination of the investigated drugs in their pharmaceutical dosage forms and their validity was assessed using the standard addition technique with mean percentage recovery ranging from 100.25 to 101.70% in the TLC method and from 99.27 to 102.12% in the D(1) method. The selectivity of the proposed methods was tested by the analysis of laboratory-prepared mixtures containing different percentages of the studied drugs and their acid degrades. The proposed methods were found selective for the determination of the intact drugs in the presence of up to 90% of their degrades in the TLC method and 70% for Lfx and 90% for Mfx and Sfx in the D(1) method.  相似文献   

20.
《Analytical letters》2012,45(11):2033-2043
Abstract

A simple isocratic high performance liquid chromatography (HPLC) method was developed for the determination of Clindamycin palmitate hydrochloride in drug substance and oral solutions. The XTerra RP18 250 mm × 4.6 mm × 5 µ column was used as stationary phase, and the mobile phase was a 0.5% solution of Triethylamine in a 1:9 (v/v) water:methanol mixture adjusted to pH 5.0 with orthophosphoric acid. The detector wavelength was selected at 210 nm and flow rate was maintained at 1.50 ml/min. Forced degradation studies were performed for drug substance, 75 mg/5 ml oral solution and placebo, using acid, base, oxidation, temperature, humidity, and photolytic degradation to demonstrate the specificity of the method. The developed method was validated as per ICH method validation guidelines.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号