首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An improved flow-based procedure is proposed for turbidimetric sulphate determination in waters. The flow system was designed with solenoid micro-pumps in order to improve mixing conditions and minimize reagent consumption as well as waste generation. Stable baselines were observed in view of the pulsed flow characteristic of the systems designed with solenoid micro-pumps, thus making the use of washing solutions unnecessary. The nucleation process was improved by stopping the flow prior to the measurement, thus avoiding the need of sulphate addition. When a 1-cm optical path flow cell was employed, linear response was achieved within 20–200 mg L−1, described by the equation S = −0.0767 + 0.00438C (mg L−1), r = 0.999. The detection limit was estimated as 3 mg L−1 at the 99.7% confidence level and the coefficient of variation was 2.4% (n = 20). The sampling rate was estimated as 33 determinations per hour. A long pathlength (100-cm) flow cell based on a liquid core waveguide was exploited to increase sensitivity in turbidimetry. Baseline drifts were avoided by a periodical washing step with EDTA in alkaline medium. Linear response was observed within 7–16 mg L−1, described by the equation S = −0.865 + 0.132C (mg L−1), r = 0.999. The detection limit was estimated as 150 μg L−1 at the 99.7% confidence level and the coefficient of variation was 3.0% (n = 20). The sampling rate was estimated as 25 determinations per hour. The results obtained for freshwater and rain water samples were in agreement with those achieved by batch turbidimetry at the 95% confidence level.  相似文献   

2.
It has been developed an automatic stop-flow procedure for sequential photometric determination of anionic and cationic surfactants in a same sample of water. The flow system was based on multicommutation process that was designed employing two solenoid micro-pumps and six solenoid pinch valves, which under microcomputer control carry out fluid propelling and reagent solutions handling. A homemade photometer using a photodiode as detector and two light emitting diodes (LEDs) with emission at 470 nm (blue) and 650 nm (red) as radiation sources, which was tailored to allow the determination of anionic and cationic surfactants in waters. The procedure for anionic surfactant determination was based on the substitution reaction of methyl orange (MO) by the anionic surfactant sodium dodecylbenzene sulfonate (DBS) to form an ion-pair with the cetyl pyridine chloride (CPC). Features such as a linear response ranging from 0.35 to 10.5 mg L−1 DBS (R = 0.999), a detection limit of 0.06 mg L−1 DBS and a relative standard deviation of 0.6% (n = 11) were achieved. For cationic surfactant determination, the procedure was based on the ternary complex formation between cationic surfactant, Fe(III) and chromazurol S (CAS) using CPC as reference standard solution. A linear response range between 0.34 and 10.2 mg L−1 CPC (R = 0.999), a detection limit of 0.05 mg L−1 CPC and a relative standard deviation of 0.5% (n = 11) were obtained. In both cases, the sampling throughput was 60 determinations per hour. Reagents consumption of 7.8 μg MO, 8.2 μg CPC, 37.2 μg CAS and 21.6 μg Fe(III) per determination were achieved. Analyzing river water samples and applying t-test between the results found and those obtained using reference procedures for both surfactant types provide no significant differences at 95% confidence level.  相似文献   

3.
Analytical procedure for the determination of toxicologically relevant arsenic (the sum of arsenite, arsenate, monomethylarsonate and dimethylarsinate) in urine by flow injection hydride generation and collection of generated inorganic and methylated hydrides on an integrated platform of a transverse-heated graphite atomizer for electrothermal atomic absorption spectrometric determination (ETAAS) is elaborated. Platforms are pre-treated with 2.7 μmol of zirconium and then with 0.10 μmol of iridium which serve both as an efficient hydride sequestration medium and permanent chemical modifier. Arsine, monomethylarsine and dimethylarsine are generated from diluted urine samples (10–25-fold) in the presence of 50 mmol L−1 hydrochloric acid and 70 mmol L−1 l-cysteine. Collection, pyrolysis and atomization temperatures are 450, 500, 2100 and 2150 °C, respectively. The characteristic mass, characteristic concentration and limit of detection (3σ) are 39 pg, 0.078 μg L−1 and 0.038 μg L−1 As, respectively. The limits of detection in urine are ca. 0.4 and 1 μg L−1 with 10- and 25-fold dilutions. The sample throughput rate is 25 h−1. Applications to several urine CRMs are given.  相似文献   

4.
Hydrogen peroxide in basic media is proposed as a means for dissolving whole blood samples to be analyzed by electrothermal atomization atomic absorption spectrometry, ET AAS. Approximately 2 g of the whole blood sample were directly weighed in a 150 mL volumetric flask; 3 mL of a NaOH 0.2 mol L−1 solution, two drops of 1-octanol, as an antifoaming agent, and 1 mL of 30% volume hydrogen peroxide were added to the flask to promote oxidation. The solution was then manually shaken and after approximately three minutes of shaking, a clear solution, with no apparent suspended solids or greasy layers, was obtained. Distilled-deionized water was used to complete the volume. Ten μL of the resulting solution along with 10 μL of a solution containing 5000 mg L−1 of NH4H2PO4 and 300 mg L−1 of Mg(NO3)2 as a modifier, were injected into transversely heated graphite tubes for lead determination. Both aqueous standards and standard addition calibration curves produced results not significantly different at a 95% confidence limit level. Accuracy of the measurements was assessed by analysis of the IAEA A-13 (concentration of trace and minor elements in freeze dried animal blood) standard reference material containing 0.18 mg L−1 lead on a dry basis and by means of recovery tests. Analysis of the IAEA A-13 standard produced 0.17 ± 0.02 mg L−1 lead on a dry basis; recovery tests afforded values from 95 to 105%. Ten consecutive measurements of a 5 ppb lead solution gave a characteristic mass of 47.2 pg and a (3S) detection limit of 1.77 μg L−1 Pb. Results obtained from analysis of whole blood samples of volunteer donors covered a lead concentration range between 8 and 21 μg L−1 with a mean value of 11.9 ± 4.7 μg L−1.  相似文献   

5.
Souza DD  Machado SA  Pires RC 《Talanta》2006,69(5):1200-1207
This paper reports on the use of multiple square wave voltammetry (MSWV) for analytical determination of paraquat herbicide at gold microelectrode (Au-ME) in different samples of natural water, food, and beverages. In this work, the MSWV consisted in a sequence of four pairs of potential pulse in the same step and the interval potential evaluated was of the 0.0 V at −1.2 V versus Ag/AgCl 3.0 mol L−1. The paraquat herbicide presented two reduction peaks, in −0.69 V and −0.99 V, with profile of the redox process totally reversible, and the use of multiple pulses allowed a detection of nanomolar levels after the optimization of experimental and voltammetric conditions. Analytical curves were constructed for pulse potential frequency of 250 s−1, pulse amplitude of 50 mV, scan increment of 2 mV and pulse number of 8 pulses in a same step. The two reduction peaks showed that the peak currents were found to be directly proportional to the pesticide concentration in the range comprised between 5.0 × 10−7 mol L−1 and 1.04 × 10−5 mol L−1. With this, it was possible to determine detection limits (DL), which resulted in 0.044 μg L−1 (0.044 ppb) and 0.146 μg L−1 (0.146 ppb), respectively, for peak 1 and peak 2. DL results, obtained using MSWV, were 2–3 orders of magnitude lower (10−2 to 10−3) less than those observed for traditional square wave voltammetry or published in literature, clearly pointing to the advantages arising from the possibility of using a MSWV for analytical purposes in contaminated matrices. In addition, the proposed methodology was applied in different samples of natural water, food and beverages without pre-treatment or pre-concentration step, where a recovery measurement indicated that the methodology could be employed to analyze paraquat in such matrices.  相似文献   

6.
Maya F  Estela JM  Cerdà V 《Talanta》2008,74(5):1534-1538
A multisyringe flow injection system (MSFIA) with spectrophotometric detection is proposed as a fast, robust and low-reagent consumption system for the determination of chloride (Cl) in waters. The system is based in the classic reaction of Cl with Fe3+ and Hg(SCN)2, but due to the hazardous properties of this last reagent, the proposed methodology has been developed with the aim to minimize the consumption of this one, consuming less than 0.05 mg of Hg for a Cl determination, being the system of this type with the lowest Hg consumption. The linear working range was between 1 and 40 mg L−1 Cl and the detection limit was 0.2 mg L−1 Cl. The repeatability (RSD) was 0.8% for a 10 mg L−1 Cl solution, and the injection throughput was 130 h−1. The proposed system is compared with other chloride monitoring flow systems, this comparison is realized with a point of view of the equilibrium between the obtained analytical features and produced residues toxicity. The proposed system was applied to the determination of Cl in mineral, tap and well water.  相似文献   

7.
In this work an automatic photometric procedure for the determination of chlorine in bleach samples employing N,N′-diethyl-p-phenylenediamine (DPD) as chromogenic reagent is described. The procedure was based on a falling drop system where the analyte (Cl2) was collected by a DPD solution drop (50 μL) after its delivery from the sample bulk that was previously acidified. The flow system was designed based on the multicommutation process assembling a set of three-way solenoid valves, which under microcomputer control afforded facilities to handle sample and reagent solution in order to control analyte delivering and solution drop generation. The analyte volatilization was improved by coupling online a little heating device. The detection system comprised a green LED (515 nm) and a phototransistor. Aiming to prove the usefulness of the proposed procedure a set of bleach samples was analyzed. Comparing the results with those obtained with reference method no significant difference at 95% confidence level was observed. Other profitable features such as a linear response ranging from 15 up to 100 mg L−1 Cl2 (R = 0.999); a detection limit of 4.5 mg L−1 Cl2 estimated based on the 3σ criterion; a relative standard deviation of 2.5% (n = 10) using a typical bleach sample containing 25.0 mg L−1 Cl2; a consumption of 55 μg of DPD per determination; and a analytical frequency of 20 determinations per hour were also achieved.  相似文献   

8.
Caffeine (1,3,7-trimethylxanthine), theobromine (3,7-dimethylxanthine) and theophylline (1,3-dimethylxanthine) are the most important naturally occurring methylxanthines. Caffeine is a constituent of coffee and other beverage and included in many medicines. Theobromine and theophylline are formed as metabolites of caffeine in humans, and are also present in tea, cocoa and chocolate products.

In order to improve the chromatographic resolution (Rs) with a good analysis time, experimental designs were applied for multivariate optimisation of the experimental conditions of an isocratic reversed-phase high-performance liquid chromatographic (RP-HPLC) method used for the simultaneous determination of caffeine, theobromine and theophylline. The optimisation process was carried out in two steps using full three-level factorial designs. The factors optimised were: flow rate and mobile phase composition. Optimal conditions for the separation of the three methylxanthines were obtained using a mixture of water/ethanol/acetic acid (75:24:1%, v/v/v) as mobile phase and a flow rate of 1.0 mL min−1. The RP-HPLC/UV method was validated in terms of limit of detection (LOD), limit of quantitation (LOQ), linearity, recovery and the precision, calculated as relative standard deviation (R.S.D.). In these conditions, the LOD was 0.10 μg L−1 for caffeine, 0.07 μg L−1 for theobromine and 0.06 μg L−1 for theophylline. The proposed method is fast, requires no extraction step or derivatization and was suitable for quantification of these methylxanthines in coffee, tea and human urine samples.  相似文献   


9.
Cui X  Fang G  Jiang L  Wang S 《Analytica chimica acta》2007,590(2):2139-259
A simple and sensitive kinetic-spectrophotometric method was developed for the determination of ultra trace amount of formaldehyde in food samples. The method was based on the oxidation of rhodamine B (RhB) by potassium bromate in sulfuric acid medium (formaldehyde as catalyst). The reaction was monitored by measuring the decrease in absorbance of the dye at 515 nm after 6 min. The developed method allowed the determination of formaldehyde in the range of 10–100 μg L−1 with good precision, accuracy and the detection limit was down to 2.90 μg L−1. The relative standard deviations for the determination of 10 and 60 μg L−1 of formaldehyde were 3.0% and 1.9% (n = 10), respectively. The method was found to be sensitive, selective and was applied to the determination of formaldehyde in foods with satisfactory results.  相似文献   

10.
Campuzano S  Pedrero M  Pingarrón JM 《Talanta》2005,66(5):1310-1319
The construction and performance under flow-injection conditions of an integrated amperometric biosensor for hydrogen peroxide is reported. The design of the bioelectrode is based on a mercaptopropionic acid (MPA) self-assembled monolayer (SAM) modified gold disk electrode on which horseradish peroxidase (HRP, 24.3 U) was immobilized by cross-linking with glutaraldehyde together with the mediator tetrathiafulvalene (TTF, 1 μmol), which was entrapped in the three-dimensional aggregate formed.

The amperometric biosensor allows the obtention of reproducible flow injection amperometric responses at an applied potential of 0.00 V in 0.05 mol L−1 phosphate buffer, pH 7.0 (flow rate: 1.40 mL min−1, injection volume: 150 μL), with a range of linearity for hydrogen peroxide within the 2.0 × 10−7–1.0 × 10−4 mol L−1 concentration range (slope: (2.33 ± 0.02) × 10−2 A mol−1 L, r = 0.999). A detection limit of 6.9 × 10−8 mol L−1 was obtained together with a R.S.D. (n = 50) of 2.7% for a hydrogen peroxide concentration level of 5.0 × 10−5 mol L−1. The immobilization method showed a good reproducibility with a R.S.D. of 5.3% for five different electrodes. Moreover, the useful lifetime of one single biosensor was estimated in 13 days.

The SAM-based biosensor was applied for the determination of hydrogen peroxide in rainwater and in a hair dye. The results obtained were validated by comparison with those obtained with a spectrophotometric reference method. In addition, the recovery of hydrogen peroxide in sterilised milk was tested.  相似文献   


11.
Dessuy MB  Vale MG  Souza AS  Ferreira SL  Welz B  Katskov DA 《Talanta》2008,74(5):1321-1329
A method has been developed for the determination of lead in wine by electrothermal atomic absorption spectrometry without any sample preparation and calibration against aqueous standards, using 7.5 μg Pd as a chemical modifier. The results obtained for seven wines using the proposed method and an acid digestion procedure did not show any significant difference using a Student's t-test. Atomization in a transversally heated filter atomizer (THFA) was compared with atomization in a conventional transversally heated platform furnace. The former provided a 2.6-fold higher sensitivity, improving the characteristic mass from 34 to 12 pg and a 1.6-fold better limit of detection (0.3 μg L−1 compared to 0.5 μg L−1) for aqueous solutions using the same injection volume of 20 μL. However, the average precision, expressed as the relative standard deviation for the determination of lead in wine under routine conditions was improved from 4.6% with platform atomization to 0.6% in the THFA. The lead content found in seven arbitrarily chosen white and red wines, five from Brazil, one from Chile and one from Spain, ranged from 6 to 60 μg L−1 Pb with an average content of 11.4 μg L−1 Pb for the wines from South America.  相似文献   

12.
The paper presents a rapid method for the determination of dioxopromethazine hydrochloride (DPZ), an antihistamine drug, by the capillary electrophoresis with electrochemiluminescene detection (CE–ECL) using tris(2,2′-bipyridyl)ruthenium(II) (Ru(bpy)32+) reagent. This CE–ECL detection method has high sensitivity, good selectivity and reproducibility for DPZ analysis. Under the optimized conditions: separation capillary, 38 cm length (25 μm i.d.); sample injection, 10 s at 8 kV; separation voltage, 12.5 kV; running buffer, 20 mmol L−1 sodium phosphate of pH 6.0; detection potential, 1.15 V; 50 mmol L−1 of phosphate buffer (pH 7.14) containing 5 mmol L−1 of Ru(bpy)32+ in ECL detection cell, the detection limit of DPZ was 0.05 μmol L−1 (S/N = 3). The linear range extended from 5 to 100 μmol L−1. The linear curve obtained was Y = 181.62 + 9.28X with a correlation coefficient of 0.9970. The relative standard deviations of the ECL intensity and the migration time for six continuous injections of 5 μmol L−1 DPZ were 3.7% and 0.92%, respectively. The CE–ECL method was applied to analyze DPZ in real samples including tablets, rat serum and human urine, and satisfactory results were obtained without interference from samples matrix. The CE–ECL technique was proved to be a potential method for the detection of DPZ in clinic analysis.  相似文献   

13.
Li YS  Ju X  Gao XF  Zhao YY  Wu YF 《Analytica chimica acta》2008,610(2):249-256
A new method for the determination of lactic acid based on the immobilization enzyme fluorescence capillary analysis (IE-FCA) was proposed. Lactic dehydrogenase (LDH) was immobilized on inner surface of a capillary with glutaraldehyde, and an immobilized enzyme lactate capillary bioreactor (IE-LCBR) was formed for the determination of lactic acid. After nicotinamide adenine dinucleotide (NAD+) is mixed with lactic acid solution, it was sucked into the IE-LCBR and was detected at λex 353 nm/λem 466 nm. Optimized conditions are as follows: the temperature is 38 °C; the reaction time is 15 min; the concentrations of Tris buffer (pH 8.8) and NAD+ are 0.1 mol L−1 and 4 mmol L−1, respectively; the concentration of LDH used for immobilization is 15 kU L−1. The concentration of lactic acid is directly proportional to the fluorescence intensity measured from 0.50 to 2.0 mmol L−1; and the analytical recovery of added lactic acid was 99–105%. The minimum detection limit of the method is 0.40 mmol L−1 and sensitivity of the IE-CBR is 4.6 F mmol−1 L−1 lactate. Its relative standard deviation (R.S.D.) is ≤2.0%. This IE-FCA method was employed for determination of lactate in milk drink.  相似文献   

14.
Jin Pan  Yuming Huang  Weiqun Shu  Jia Cao 《Talanta》2007,71(5):1861-1866
At pHs ≥ 11.45, trace Al was found to enhance the CL from luminol–KMnO4 system. However, at pHs ≤ 10.42, it was found to inhibit strongly the CL from luminol–KMnO4 system. The effect of pH, luminol and potassium permanganate concentrations on the kinetic characteristics of CL system was investigated in the presence of trace Al. On this basis, a flow injection inhibition chemiluminescence method was established for the determination of trace Al in this study. Under optimized conditions, the CL decreased linearly with Al(III) concentration in the range of 8–500 μg L−1 and the detection limit (3σ) of 2 μg L−1. The relative standard deviation (R.S.D.) is 3.6% for 100 μg L−1 Al(III) (n = 11). The method has been applied to the determination of trace Al in real water samples with satisfactory results without the pretreatment of samples. The results given by the proposed method are in good agreement with those given by ICP-AES detection method.  相似文献   

15.
The behavior of selenium in thermospray flame furnace atomic absorption spectrometry (TS-FF-AAS) was studied and the developed procedure was applied for selenium determination in biological materials after microwave-assisted sample digestion. A sample volume of 600 μL was introduced into the hot metallic Ni tube at a flow rate of 0.4 mL min−1 using water as carrier. The limit of detection obtained for Se was 8.7 μg L−1 (3sblank/slope, n = 10), which is 95-fold better than that typically obtained using FAAS. The applicability of the TS-FF-AAS procedure was evaluated for selenium determination in biological materials. Certified reference materials of pig kidney (BCR 186) and mussel (GBW 08571) were analyzed and a t-test had not shown any statistically significant difference at a 95% confidence level between determined and certified values for both materials. The procedure was successfully applied for determination of Se in pig kidney and shellfish. It was demonstrated that TS-FF-AAS improved the performance of FAAS (flame atomic absorption spectrometry) for determination of Se.  相似文献   

16.
Xiaohong Li  Yingying Su  Kailai Xu  Xiandeng Hou  Yi Lv   《Talanta》2007,72(5):1728-1732
A simple, sensitive and interference-free method was proposed for the determination of arsenic, based on the generation of volatile arsenic trichloride coupled with atomic fluorescence spectrometry. Thiourea, together with l-ascorbic acid, was used to reduce As(V) to As(III), and the chloride generation was based on the reaction between As(III) and hydrochloric acid. Under the optimized experimental conditions, the present procedure allows for the quantification of arsenic in the concentration range of 0.01–4.0 mg L−1, with a limit of detection (3σ) of 6.0 μg L−1. The relative standard deviation (R.S.D.) is 4.0% for 0.1 mg L−1 arsenic (n = 7). Finally, the proposed method was successfully applied to the determination of arsenic in several certified reference samples (stainless steel, alloy steel, copper alloy and water sample) and real samples (brass material and spiked cobalt material), with analytical results well-agreed with those by ICP-MS.  相似文献   

17.
Duan T  Song X  Jin D  Li H  Xu J  Chen H 《Talanta》2005,67(5):968-974
In this work, a method was developed for determination of ultra-trace levels of Cd in tea samples by atomic fluorescence spectrometry (AFS). A flow injection solid phase extraction (FI-SPE) separation and preconcentration technique, to on-line couple with a sequential injection hydride generation (SI-HG) technique is employed in this study. Cd was preconcentrated on the SPE column, which was made from a neutral extractant named Cyanex 923, while other matrix ions or interfering ions were completely or mostly separated off. Conditions for the SPE separation and preconcentration, as well as conditions for the HG technique, were studied. Due to the separation of interfering elements, Cd hydride generation efficiency could be greatly enhanced with the sole presence of Co2+ with a concentration of 200 μg L−1, which is much lower than those in other works previously reported. Interferences on both the Cd separation and preconcentration, and Cd hydride generation (HG) were investigated; it showed that both the separation and preconcentration system, and the HG system had a strong anti-interference ability. The SPE column could be repeatedly used at least 400 times, a R.S.D. of 0.97% was obtained for 6 measurements of Cd with 0.2 μg L−1 and a correlation coefficiency of 1.0000 was obtained for the measurement of a series of solutions with Cd concentrations from 0.1 to 2 μg L−1. The method has a low detection limit of 10.8 ng L−1 for a 25 mL solution and was successfully validated by using two tea standard reference materials (GBW08513 and GBW07605).  相似文献   

18.
A procedure for chromium preconcentration and speciation with a dual mini-column sequential injection system coupled with electrothermal atomic absorption spectrometry (ETAAS) was developed. At pH 6, the sample solution was firstly aspirated to flow through a Chlorella vulgaris cell mini-column on which the Cr(III) was retained. The effluent was afterwards directed to flow through a 717 anion exchange resin mini-column accompanied by the retention of Cr(VI). Thereafter, Cr(III) and Cr(VI) were eluted by 0.04 mol L− 1 and 1.0 mol L− 1 nitric acid, respectively, and the eluates were quantified with ETAAS. Chemical and flow variables governing the performance of the system were investigated. By using a sampling volume of 600 µL, sorption efficiencies of 99.7% for Cr(III) and 99% for Cr(VI) were achieved along with enrichment factors of 10.5 for Cr(III) and 11.6 for Cr(VI), within linear ranges of 0.1–2.5 µg L− 1 for Cr(III) and 0.12–2.0 µg L− 1 for Cr(VI). Detection limits of 0.02 µg L− 1 for Cr(III) and 0.03 µg L− 1 for Cr(VI) along with RSD values of 1.9% for Cr(III) and 2.5% for Cr(VI) (1.0 µg L− 1, n = 11) were obtained. The procedure was validated by analyzing a certified reference material of GBW08608 and further demonstrated by chromium speciation in river and tap water samples.  相似文献   

19.
A direct immersion solid-phase microextraction coupled with gas chromatography-electron capture detection (SPME-GC-ECD) method was optimized and validated for the quantitative determination of 18 organochlorine pesticides in ground water. Ionic strength, stirring speed, adsorption and desorption time and pH were some of the parameters investigated in order to select the optimum conditions for SPME with a 50/30 DVB/CAR/PDMS fiber coating. The SPME-GC/ECD method showed good linear response below 10 ng L−1 with R2 values in the range of 0.9950–0.9997. The repeatability of the measurements were lower than 10%. Values of relative recoveries located within the acceptable range (80–120%). Limits of quantification (LOQ) from 4.5 × 10−3 to 1.5 ng L−1 were obtained. On average 8 organochlorines were found per sample, even so all the 18 organochlorines were quantified among them. Substances such as endrin ketone, γ-BHC and β-BHC were the pesticides determined in larger concentration (0.06–305 ng L−1), while methoxychlor and aldrin in smaller amounts (0.151–1.55 ng L−1). Measured levels of organochlorine pesticides were above the limits established by Brazilian regulations.  相似文献   

20.
The proposed flow system was developed in order to minimize the drawbacks related to the PGEs determination by quadrupole-inductively coupled plasma-mass spectrometry (Q-ICP-MS). It was intended not only to lower the limits of detection (LODs) but also to eliminate the interferences originating from some atomic and molecular ions produced in the argon plasma. This was accomplished by means of an on-line sample clean-up/pre-concentration step, using a chelating resin (Metalfix™ Chelamine™) in which Rh, Pd and Pt were preferably retained when compared with the interfering species.

The results obtained by using the developed flow system in the analysis of urine samples are presented. With a sampling rate of 9 samples h−1 (i.e., 27 determinations) and a sample consumption of ca. 10 mL, the developed flow system allowed linear calibration plots up to 100 ng L−1 with detection limits of 1.2 ng L−1 (Rh), 0.4 ng L−1 (Pd) and 0.9 ng L−1 (Pt). Repeatability studies showed good precision (R.S.D.%, n = 5): 3.7% (Rh); 2.6% (Pd) and 2.4% (Pt), for 10 ng L−1; 2.4% (Rh); 1.4% (Pd) and 1.9% (Pt), for 50 ng L−1; and 1.3% (Rh); 0.58% (Pd) and 0.62% (Pt), for 100 ng L−1. By spiking human urine samples, recovery tests were performed, and the values obtained ranged between 89% and 105% (Rh); 90% and 104% (Pd); and 93% and 105% (Pt).  相似文献   


设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号