Wu XZ  Zhang LH  Onoda K 《Electrophoresis》2005,26(3):563-570
Carrier ampholyte-free isoelectric focusing (IEF) sample injection (concentration) for capillary electrophoresis (CE) is realized in a single capillary. A short section of porous capillary wall was made near the injection end of a capillary by HF etching. In the etching process, an electric voltage was applied across the etching capillary wall and electric current was monitored. When an electric current through the etching capillary was observed, the capillary wall became porous. The etched part was fixed in a vial, where NaOH solution with a certain concentration was added during the sample injection. The whole capillary was filled with pH 3.0 running buffer. The inlet end vial was filled with protein sample dissolved in the running buffer. An electric voltage was applied across the inlet end vial and etched porous wall. A neutralization reaction occurs at the boundary (interface) of the fronts of H+ and OH-. A pH step or sharp pH gradient exists across the boundary. When positive protein ions electromigrate to the boundary from the sample vial, they are isoelectricelly focused at points corresponding to their pH. After a certain period of concentration, a high voltage is applied across the whole capillary and a conventional CE is followed. An over 100-fold concentration factor has been easily obtained for three model proteins (bovine serum albumin, lysozyme, ribonuclease A). Furthermore, the IEF sample concentration and its dynamics have been visually observed with the whole-column imaging technique. Its merits and remaining problem have been discussed, too.  相似文献   

2.
A new sample introduction method of capillary electrophoresis, in which field-amplified sample injection was combined with a pre-concentration of non-uniform field electrophoresis, is presented in this paper. With an additional pre-concentration voltage applied to sample solution, a non-uniform electric field was generated, with which analytical cations or anions were pre-concentrated around an electrode adjacent to the injection end of capillary. After the pre-concentration, analytical ions were injected into the capillary and stacked at the boundary between sample and buffer solution inside capillary by field-amplified injection technique. In contrast to the conventional field-amplified injection, larger concentration factor and higher analytical sensitivity were obtained with the improved pre-concentration method. Its concentration factor was about 10 approximately 15 fold as that of field-amplified sample injection.  相似文献   

3.
Hadamard transform capillary electrophoresis (HTCE) based on electrokinetic injection allows laser-induced fluorescence detection using a small laser, namely the laser-diode-pumped YAG laser, as an excitation source. A small hole is fabricated at the center of a capillary by laser ablation; this hole functions as an inlet port for a sample solution. Therefore, the sample solution can be introduced electrophoretically into the capillary through the small hole. Multiple sample injection is accomplished by introducing a buffer solution from the end of the capillary and the sample solution through the hole. Both solutions are injected using two sets of high-voltage power supplies and migrate toward the opposite end of the capillary. A fluorescent analyte, rhodamine B, is successfully detected in the case of both single and multiple injection according to the Hadamard sequence code. By transforming the data encoded by the Hadamard matrix, the decoded data showed an increase in the signal-to-noise (S/N) ratio by a factor of 9.8. In the case of the sample containing two amino acids labeled with rhodamine B isothiocyanate (RBITC), although the concentration of every component including free RBITC is lower than the concentration limit of detection obtained by single injection, a substantial improvement in the sensitivity is achieved and all components are identified by the Hadamard transform technique.  相似文献   

4.
Z Liu  K Otsuka  S Terabe 《Electrophoresis》2001,22(17):3791-3797
The feasibility of open-tubular capillary electrochromatography (OTCEC) with UV detector for quantitation of enantiomers is explored, and a simple on-line sample concentration method to improve detection sensitivity of negatively charged enantiomers more than 1000-fold is described. With a capillary of 25 microm ID, the limits of detection (LODs) for absolute concentration and for enantiomeric ratio are 10(-6) M and 0.6-0.8% (signal-to-noise ratio S/N = 10). Good linearity and reproducibility are observed. The detection sensitivity is enhanced by combination with field-enhanced sample injection (FESI). A water plug is introduced hydrodynamically into the capillary inlet end and then the sample solution prepared with water is introduced with electrokinetic injection. With this concentration technique, the LOD for absolute concentration is reduced to a 10(-9) M level. On the other hand, due to the peak-sharpening effect of FESI, the LOD for enantiomeric ratio for the first-eluted enantiomer is significantly improved, being 0.3%. Effects of the injection conditions, such as length of water plug, buffer concentration, injection voltage, and injection time on the enrichment efficiency are investigated. Online concentration of a racemic compound with two chiral centers is demonstrated.  相似文献   

5.
A quantitative sample introduction method based upon inkjet injection was applied to capillary electrophoresis coupled with stacking and sweeping on‐line concentration techniques. Methylxanthines were used as model compounds for the proof‐of‐concept of the method. The volume of injected sample could be easily manipulated by controlling the number of ejected droplets in the injection procedure. Under optimized conditions, a linear relationship between the ejected droplet number and peak area was obtained when the droplet number introduced into the capillary was less than 100. Under optimized quantitative on‐line concentration conditions, the limits of detection for theobromine, caffeine, and theophylline were 1.0, 2.0, and 1.0 μM, respectively. The inkjet injection system was evaluated by comparing it with conventional injection methods. The electropherogram of the inkjet injection mode was the same as that for hydrodynamic injection mode, and no sample discrimination was observed compared with the electrokinetic injection mode. The established method was applied to the determination of methylxanthines in bottled green tea. The recoveries of theobromine, caffeine, and theophylline were 94.1, 110.6, and 86.8%, respectively. We conclude that proposed method can be used for quantitative concentration for capillary electrophoresis, thus resulting in an improved accuracy.  相似文献   

6.
A single step on-line concentration and separation method for peptides in non-aqueous capillary electrophoresis was developed. ACN containing 50 mM tetraethylammonium perchlorate was used as the electrophoretic medium; angiotensins I-IV were separated as a result of the differences in the magnitudes of their interactions with perchlorate anions. When the sample solution (ACN containing 0.5% trifluoroacetic acid and angiotensins) was injected as a large-volume plug, the analytes were concentrated at the inlet end of the capillary by both sweeping and stacking mechanisms; the separation procedure then started automatically without any operations such as polarity change. It was found that the concentration of analytes, injection period, and concentration of tetraethylammonium perchlorate in the electrophoretic medium were important factors for both separation and concentration efficiencies. The angiotensins were concentrated and separated with the large-volume injection of up to 80% of the effective capillary length.  相似文献   

7.
Wang J  Chen L 《Talanta》1995,42(3):385-389
Ultrasmall-volume measurements of oxidizable compounds have been accomplished by coupling a capillary flow injection system with amperometric detection. Remarkably low (femtomole) mass detection limits result from the combination of nanoliter sample volume and the inherent sensitivity of the wall-jet detector. A substantial economy of reagent consumption and disposal accrues from the operation of the nl/min flow regime. Variables influencing the physical dispersion in the capillary flow injection system, including capillary length, sample volume or flow rate, are explored and optimized.  相似文献   

8.
Fan L  Cheng Y  Li Y  Chen H  Chen X  Hu Z 《Electrophoresis》2005,26(22):4345-4354
A simple, effective, and continuous online concentration method for the sensitive detection of alkaloids applying CE-flow injection analysis with head-column field-amplified sample stacking was developed. A series of samples was continuously introduced into the capillary by electrokinetic means without interrupting the high voltage. A short water plug was introduced by the EOF at the capillary inlet end prior to sample introduction. Under optimum conditions, 15-fold improvement in concentration sensitivity was achieved, giving an LOD of about 0.67 and 0.73 microg/mL for ephedrine (E) and pseudoephedrine (PE), respectively. The separation could be achieved within 4 min and sample throughput rate could reach up to 7/h. The repeatability (defined as RSD) was 3.62, 1.51% with peak area evaluation and 1.30, 2.58% with peak height evaluation for E and PE, respectively. This method has been successfully applied to the analysis of commercial pharmaceutical preparations containing E and PE, and the recoveries were 92.3-102.4%.  相似文献   

9.
Shihabi ZK 《Electrophoresis》2002,23(15):2394-2398
The work presented here demonstrates that electroinjection can be performed using discontinuous buffers, which can result in better stacking than that obtained by hydrodynamic injection. The sample can be concentrated at the tip of the capillary leaving practically the whole capillary for sample separation. This results in several advantages, such as better sample concentration, higher plate number and shorter time of stacking. However, sample introduction by electromigration is suited for samples free or low in salt content. Samples, which are high in salt content, are better introduced by the hydrodynamic injection for stacking by the discontinuous buffers. Different simple methods to introduce the discontinuity in the buffer for electroinjection are discussed.  相似文献   

10.
Cheng YQ  Yao B  Zhang HD  Fang J  Fang Q 《Electrophoresis》2010,31(19):3184-3191
A high-speed DNA fragment separation system was developed based on a short capillary and a slotted-vial array automated sample introduction system. The injection process of DNA sample in a short capillary was investigated systematically with three injection techniques including constant-field-strength, low-field-strength and translational spontaneous injections. Under the optimized conditions, picoliter-scale sample plugs (corresponding to ca. 20-μm plug length) were obtained, which ensure the high-speed and high-efficiency separation for DNA fragments with a short effective separation length. Other separation conditions including the sieving matrix concentration, separation field strength and effective separation length were also optimized. The present system was applied in the separation of ΦX174-Hae III digest DNA marker. With an effective separation length of 2.5 cm, the separation could be achieved in <100 s with plate heights ranging from 0.21 to 0.74 μm (corresponding to plate numbers from 4.86 × 10(6) to 1.36 × 10(6)/m). The repeatabilities for the migration time of the eleven fragments were between 0.4 and 1.1% RSD (n=8). By using the automated continuous injection method, the separation for four different DNA samples could be achieved within 250 s. The present system was further applied in the fast sizing of real DNA samples of PCR products.  相似文献   

11.
Electrokinetic supercharging (EKS), a new and powerful on-line preconcentration method for capillary electrophoresis, was utilized in non-aqueous capillary electrophoresis (NACE) to enhance the sensitivity of phenolic acids. The buffer acidity and concentration, leader and terminator length and electrokinetic injection time were optimised, with the optimum conditions being: a background electrolyte of 40 mM Tris-acetic acid (pH 7.9), hydrodynamic injection of 50 mM ammonium chloride (22 s, 0.5 psi) as leader, electrokinetic injection of the sample (180 s, -10 kV), hydrodynamic injection of 20 mM CHES (32 s, 0.5 psi) as terminator, before application of the separation voltage (-25 kV). Under these conditions the sensitivity was enhanced between 1333 and 3440 times when compared to a normal hydrodynamic injection with the sample volume <3% of the capillary volume. Detection limits for the seven phenolic acids were in the range of 0.22-0.51 ng/mL and EKS was found to be 3.6-7.9 times more sensitive than large-volume sample stacking and anion selective exhaustive injection for the same seven phenolic acids.  相似文献   

12.
A simple construction of a split-flow injector eliminating some common problems connected with the use of such devices is described. It consists of a low-pressure pump, an injection valve and a delivery tube in which the separating capillary inlet is fixed. The sample is injected without moving the separating capillary inlet and without interrupting the applied voltage. The grounded electrophoretic electrode is close to the injection valve so that all metal parts of the injector are kept at a sufficiently low potential. Minimum length and small internal diameter of delivery tube minimizes additional sample zone broadening. The effects of some experimental parameters, such as the position of the separation capillary inlet with respect to the background solution flow direction and background solution flow-rate are experimentally studied. The injector was tested primarily for the electrokinetic injection.  相似文献   

13.
Fang N  Meng P  Zhang H  Sun Y  Chen DD 《The Analyst》2007,132(2):127-134
The combination of exhaustive electrokinetic injection and sweeping micellar electrokinetic chromatography (sweeping-MEKC) in capillary electrophoresis often provides a several thousand-fold improvement in concentration detection limit. However, reproducibility of this method has been a major issue that often prevents its use as a quantitative tool for the analysis of ultra-trace analytes in complex matrices. In this paper, we demonstrate that such a technique can be systematically optimized with five key factors: the conductivity of the sample solution, the conductivities of the separation buffers, the fraction of the capillary that is filled with the high conductivity buffer, the electrokinetic injection time, and the surfactant concentration. By controlling the sample conductivity, we were able to achieve highly reproducible results, while still maintaining the sensitivity of field-amplified sample injection. At optimal conditions, we were able to analyze three amine drugs (amphetamine, methamphetamine, and methylenedioxymethamphetamine) with limits of detection of 6 to 8 pg ml(-1) (ppt), which is a several thousand-fold improvement over normal sample injection using CE with a photodiode array detector.  相似文献   

14.
A novel, rapid and continuous on-line concentration approach based on dynamic pH junction for the analysis of trimethoprim (TMP) and sulfamethoxazole (SMZ) by microfluidic capillary electrophoresis (CE) combined with flow injection analysis is developed in this paper. Stacking is due to decreases in the velocity of analytes when migrating from the low-pH sample zone (sample was dissolved in 50 mM HCl) to a relatively high-pH buffer (30 mM phosphate buffer, pH 8.5) filled in the capillary. This results in 2.9-4.7-fold improvement in concentration sensitivity relative to conventional capillary electrophoresis methods. The separation could be achieved within 2 min and sample throughput rate can reach up to 38 h(-1).  相似文献   

15.
A capillary electrophoresis method for the analysis of intact heparin was developed using a phosphate buffer and a fused silica capillary. Operational parameters such as pH and concentration of the running buffer were investigated. The short end injection configuration permitted a gain on peak efficiency, on the analysis time and on the repeatability of both migration times and peak areas, through a reduction of the migration distance. Moreover, the beneficial effect of the presence of sodium chloride in the heparin sample on the peak efficiency was demonstrated and the influence of the salts on the conformation of the heparin was discussed. The optimized method (short end injection configuration, 50mM phosphate buffer pH 3, heparin sample prepared in 10 g/L NaCl solution) was validated in terms of linearity, reproducibility and specificity according to ICH requirements.  相似文献   

16.
When using capillary electrophoresis (CE) for the analysis of biological samples, it is often necessary to employ techniques to overcome peak-broadening that results from having a high-conductivity sample matrix. To improve the concentration detection limits and separation efficiency of cationic pharmaceuticals in CE, pH-mediated acid stacking was performed to electrofocus the sample, improving separation sensitivity for the analyzed cations by 60-fold. However, this method introduces a large titrated acid plug into the capillary. To overcome the limitations this low-conductivity plug poses to stacking, the plug was removed prior to the separation step by applying reverse pressure to force it out of the anode of the capillary. Employing this technique allows for roughly twice the volume of sample to be injected. A maximum sample injection time of 240 s was attainable with baseline peak resolution compared to a maximum sample injection time of 120 s without reverse pressure, leading to a twofold decrease in the limits of detection of the analytes used. Separation efficiency overall is also improved when utilizing the reverse pressure step. For example, a 60 s sample injection time results in 94,000 theoretical plates as compared to 60,500 theoretical plates without reverse pressure. This reverse-pressure method was used for detection and quantitation of several cationic pharmaceuticals that were prepared in Ringer's solution to simulate microdialysis sampling conditions.  相似文献   

17.
An on-line sample introduction technique in capillary gas chromatograph (CGC) for the analysis of high-pressure gas-liquid mixtures has been designed and evaluated. A sample loop of 0.05 microL and a washing solvent loop of 0.5 microL are mounted on a 10-port switching valve, which serves as the injection valve. A capillary resistor was connected to the vent of sample loop in order to maintain the pressure of the sample. Both the sample and the washing solvent are transferred into the split-injection port through a narrow bore fused silica capillary inserted into the injection liner through a septum. The volume of the liner is used both as the pressure-release damper and evaporation chamber of the sample. On-line analysis of both reactants and resultants in ethylene olimer reaction mixture at 5 MPa was carried out, which demonstrated the applicability of the technique.  相似文献   

18.
A capillary electrophoresis method with UV-absorbance detection was studied and optimized for the determination of underivatized amino acids in urine. To improve concentration sensitivity the utility of in-capillary analyte stacking via dynamic pH junction was investigated with phenylalanine (Phe) and tyrosine (Tyr) as model amino acids. Before sample injection, a plug of ammonium hydroxide solution was injected to enable analyte concentration. Samples were 1:1 (v/v) mixed with background electrolyte (1 M formic acid) prior to injection. The effect of the injected sample volume, and the injected ammonium hydroxide volume and concentration on analyte stacking and separation performance was investigated. The optimal volume of ammonium hydroxide depended on the injected sample volume. Using a dynamic pH junction good resolution (1.4) was obtained for a sample injection volume of 10% of the capillary (196 nl) with Phe and Tyr dissolved in water. Limits of detection (LODs) were 0.036 and 0.049 μM for Phe and Tyr, respectively. For urine samples, the optimized procedure comprised a 1.7-nl injection of 12.5% ammonium hydroxide, followed by a 196-nl injection of urine spiked with Phe and Tyr. Satisfactory resolution was obtained and amino acid peak widths at half height were only 1.6 s indicating efficient stacking. Calibration plots for Phe and Tyr in urine showed good linearity (R(2) > 0.96) in the concentration range 10-175 μM, and LODs for Phe and Tyr were 0.054 and 0.019 μM, respectively. RSDs for peak area and migration time for Phe and Tyr were below 7.5% and 0.75%, respectively.  相似文献   

19.
A two-dimensional capillary electrophoresis platform, combining isoelectric focusing (IEF) and capillary zone electrophoresis (CZE), was established on a microchip with the channel width and depth as 100 mum and 40 mum, respectively. With polyacrylamide as permanent coating, EOF in the microchannel, which could impair the separation, was decreased to 3.4x10(-9)m(2).V(-1).s(-1), about 1/10 of that obtained in the uncoated set-up. During the separation, peptides were first focused by IEF in the first dimensional channel, and then directly driven into the perpendicular channel by controlling the applied voltages, and separated by CZE. Effects of various experimental parameters, including the electric field strength, channel length, and injection frequency from the first to the second dimensional separation channel, were studied. Under optimized condition, the digests of BSA and proteins extracted from E. coli were separated, and a peak capacity of 540 was obtained, which was far greater than that obtained by each single dimensional separation. All these results showed the promise of multidimensional separation on a microchip for the high-throughput and high-resolution analysis of complex samples.  相似文献   

20.
E Morcos  N P Wiklund 《Electrophoresis》2001,22(13):2763-2768
Nitrite and nitrate have been widely used as markers for nitric oxide (NO) formation in vivo and represent the major NO oxidation products in biological fluids. In the present study, the use of capillary electrophoresis (CE) in the measurement of nitrite and nitrate in human urine is described. Urine samples were electrophoresed in an extended light path fused-silica capillary (104 cm; 75 microm ID) at an applied negative potential of 30 kV, and UV detection at 214 nm. Using electrokinetic sample injection (-6 kV x 20 s), we found that urine concentration, pH, sodium and chloride interfered with nitrite and nitrate detection. The detection of nitrite and nitrate was decreased when hydrodynamic sample injection was used (30 mbar x 60 s). However, basal levels of urinary nitrite (0.25 +/- 0.05 microM) and nitrate (591 +/- 115 microM) were detected and no interference by variations in urine concentration and pH was noted when hydrodynamic sample injection was used. Thus, hydrodynamic sample injection is convenient for the measurement of urinary nitrite and nitrate and avoids the effect of variations in urine matrices and pH on nitrite and nitrate detection.  相似文献   