首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 109 毫秒
1.
Incorporation of palladium nanoparticles on the surface of multi-walled carbon nanotubes and modification of glassy carbon electrode with the prepared nano-hybrid material led to the fabrication of a novel electrode. The modified electrode showed attractive electrocatalytic activity and sensitizing effect on luminol-O(2) and luminol-H(2)O(2) electrochemiluminescence (ECL) reactions at neutral media. The sensitized luminol-O(2) and luminol-H(2)O(2) reactions were successfully applied for the ECL determination of dissolved O(2) and glucose, respectively. Under the optimal conditions for luminol-O(2) system, the ECL signal intensity of luminol was linear with the concentration of dissolved oxygen in the range between 0.08 and 0.94 mM (r=0.9996) and for luminol-H(2)O(2) system, the ECL signal intensity of luminol was linear with the concentration of glucose in the range between 0.1 and 1000 μM (r=0.9998). The limits of detection (S/N=3) for dissolved oxygen and glucose were 0.02 mM and 54 nM, respectively. The relative standard deviations (RSD) for repetitive measurements of 0.50 mM oxygen (n=10) and 10 μM glucose (n=30) were 3.5% and 0.3%, respectively. Also, under the optimal conditions for luminol-H(2)O(2) system, the ECL signal intensity of luminol was linear with the concentration of H(2)O(2) in the range between 1 nM and 0.45 mM (r=0.9997). The limit of detection (S/N=3) for H(2)O(2) detection was 0.5 nM and the relative standard deviation for repetitive measurements of 10 μM H(2)O(2) (n=10) was 0.8%.  相似文献   

2.
Electrogenerated chemiluminescence (ECL) of luminol on a gold-nanorod-modified gold electrode was studied, and five ECL peaks were obtained under conventional cyclic voltammetry in both neutral and alkaline solutions. Among them, four ECL peaks (ECL-1-4) were also observed on a gold-nanosphere-modified gold electrode, but the intensities of these ECL peaks were enhanced about 2-10-fold on a gold-nanorod-modified gold electrode in neutral solution. One new strong ECL peak (ECL-5) was obtained at -0.28 V (vs SCE) on a gold-nanorod-modified gold electrode in both neutral and alkaline solutions and enhanced with an increase in pH. In strong alkaline solutions, ECL-1 and ECL-2 on a gold-nanosphere-modified electrode were much stronger than those on a gold-nanorod-modified gold electrode, while ECL-3-5 appeared to only happen on a gold-nanorod-modified gold electrode. The emitter of all the ECL peaks was identified as 3-aminophthalate. The ECL peaks were found to depend on the scan direction, the electrolytes, the pH, and the presence of O(2) and N(2). The reaction pathways for ECL-4 have been further elucidated, and the mechanism of the new ECL peak (ECL-5) has been proposed. The results indicate that a gold-nanorod-modified gold electrode has a catalytic effect on luminol ECL different from that of a gold-nanosphere-modified gold electrode, revealing that the shape of the metal nanoparticles has an important effect on the luminol ECL behavior. The strong ECL of luminol in neutral solution obtained on a gold-nanorod-modified electrode may be used for the sensitive detection of biologically important compounds in physiological conditions.  相似文献   

3.
In this paper, we describe the electrochemiluminescent (ECL) behavior of Ru(bpy)33+-incorporated clay colloids. Experimental results based on the electrochemical-quartz-crystal-microbalance (EQCM) techniques showed that Ru(bpy)33+ could be adsorbed by the clay colloids (montmorillonite K10, denoted K10). The resulting clay particles could emit light (λem 610 nm) when they were fabricated as thin films sandwiched by two conductive ITO electrodes with opposite biases. These Ru(bpy)33+-incorporated clay-modified electrodes could also emit light in aqueous oxalate solutions (pH 10) when potentials more positive than 0.9 V vs. SCE were applied. EDTA was an effective promoter for the Ru(bpy)3 (clay)3+-oxalate ECL reaction. The resulting ECL showed a remarkable sensitivity to oxygen. A glucose optrode was thus fabricated based on the Ru(bpy)33+-incorporated K10 colloids and glucose oxidase (GOx). The ECL signals behaved as a function of [glucose], covering a range from 0.1 to 10 mM at pH 10. The detection limits reached a level of 0.1 mM at this pH.  相似文献   

4.
Yu Z  Wei X  Yan J  Tu Y 《The Analyst》2012,137(8):1922-1929
With TiO(2) nanoparticles as carrier, a supported nano-material of Au atomic cluster/TiO(2) nano-hybrid was synthesized. It was then modified onto the surface of indium tin oxide (ITO) by Nafion to act as a working electrode for exciting the electrochemiluminescence (ECL) of luminol. The properties of the nano-hybrid and the modified electrode were characterized by XRD, XPS, electronic microscopy, electrochemistry and spectroscopy. The experimental results demonstrated that the modification of this nano-hybrid onto the ITO electrode efficiently intensified the ECL of luminol. It was also revealed that the ECL intensity of luminol on this modified electrode showed very sensitive responses to oxygen and hydrogen peroxide. The detection limits for dissolved oxygen and hydrogen peroxide were 2 μg L(-1) and 5.5 × 10(-12) M, respectively. Besides the discussion of the intensifying mechanism of this nano-hybrid for ECL of luminol, the developed method was also applied for monitoring dissolved oxygen and evaluating the scavenging efficiency of reactive oxygen species of the Ganoderma lucidum spore.  相似文献   

5.
A carbon nanotube paste (CNTP) electrode and a carbon nanotube paste/glucose oxidase (CNTP/GOx) electrode were prepared, and the electrochemiluminescent (ECL) behavior of luminol in the presence of glucose was investigated in detail at each of these electrodes. Compared to the classical carbon paste (CP) electrode, the CNTP electrode incorporating glucose oxidase greatly enhanced the response of the ECL sensor to glucose due to the electrocatalytic activity of the carbon nanotubes, the specificity of the enzymatic reaction, and the sensitivity of the luminol ECL reaction. Under optimal conditions, the electrode was found to respond linearly to glucose in the concentration range 1.0x10(-6) approximately 2.0x10(-3) mol/L, and the detection limit (defined as the concentration that can be detected at a signal-to-noise ratio of 3) was found to be a glucose concentration of 5.0x10(-7) mol/L. The method used to prepare the CNTP/GOx electrode was very convenient, and the electrode surface could be renewed in the case of fouling by simply polishing or cutting it to expose a new and fully active surface. The relative standard deviations (RSD) were found to be 6.8% and 8.9% for the CNTP electrode and the CNTP/GOx electrode (n=6). The electrode retained 95% of its initial response after two weeks.  相似文献   

6.
It was found that chloroauric acid (HAuCl(4)) could be directly reduced by the luminescent reagent luminol in aqueous solution to form gold nanoparticles (AuNPs), the size of which depended on the amount of luminol. The morphology and surface state of as-prepared AuNPs were characterized by transmission electron microscopy, UV/visible spectroscopy, X-ray photoelectron spectroscopy, FTIR spectroscopy, and thermogravimetric analysis. All results indicated that residual luminol and its oxidation product 3-aminophthalate coexisted on the surface of AuNPs through the weak covalent interaction between gold and nitrogen atoms in their amino groups. Subsequently, a luminol-capped AuNP-modified electrode was fabricated by the immobilization of AuNPs on a gold electrode by virtue of cysteine molecules and then immersion in a luminol solution. The modified electrode was characterized by cyclic voltammetry, electrochemical impedance spectroscopy, and scanning electron microscopy. The as-prepared modified electrode exhibited an electrochemiluminescence (ECL) response in alkaline aqueous solution under a double-step potential. H2O2 was found to enhance the ECL. On this basis, an ECL sensor for the detection of H2O2 was developed. The method is simple, fast, and reagent free. It is applicable to the determination of H2O2 in the range of 3x10(-7)-1x10(-3) mol L(-1) with a detection limit of 1x10(-7) mol L(-1) (S/N=3).  相似文献   

7.
Mononuclear ruthenium complex 1 and dinuclear complex 2 were synthesized by reaction of the appropriate bidentate pyrazolyl-pyridyl-based ligand L (L = 1,4-bis(3-(2-pyridyl)pyrazol-1-ylmethyl)benzene) with cis-Ru(bipy)(2)Cl(2)·2H(2)O. They were characterized by elemental analyses, ESI-MS, (1)H spectroscopy, and X-ray crystallography for 2. Compounds 1 and 2 both emit strongly in solid states and in solutions at 298 K with the lifetimes in the microsecond range. Electrogenerated chemiluminescence (ECL) of complexes 1 and 2 in the absence or presence of coreactant tri-n-propylamine (TPrA) or 2-(dibutylamino)ethanol (DBAE) at different working electrodes in acetonitrile and phosphate buffer solutions (PBS, pH 7.5) was studied. The ECL spectra are identical to the photoluminescence spectra, indicating that the ECL emissions are due to the metal to ligand charge transfer (MLCT). In all cases, ECL quantum efficiencies of dinuclear complex 2 are higher than those of mononuclear complex 1, and ECL quantum efficiencies of complexes 1 and 2/TPrA system are higher than those of DBAE system. It is noted that diuretic furosemide tends to decrease the ECL intensity of complex 2/TPrA system in PBS (pH 7.5) at GC working electrode. A novel ECL method for the determination of diuretic furosemide was developed with a linear range between 2.0 × 10(-7) mol L(-1) and 1.0 × 10(-6) mol L(-1), and a detection limit of 1.2 × 10(-8) mol L(-1) based on 3 times the ratio of signal-to-noise.  相似文献   

8.
Wang J  Chen G  Huang J 《The Analyst》2005,130(1):71-75
A glassy carbon electrode (GCE) modified with nickel(II) tetrasulfophthalocyanine (NiTSPc) and Nafion was used for the investigation of the catalytic oxidation of luminol. The modified electrode was found to much more effectively improve the emission of electrochemiluminescence(ECL) of luminol in a solution containing hydrogen peroxide. The enhanced ECL signal corresponded to the catalytic oxidation of both luminol and H(2)O(2) by NiTSPc. Attached Ni(II) on GCE was oxidised to Ni(III) and then used as the catalyst for the chemiluminescence of luminol. The enhanced stability of the ECL signal with Nafion would mainly result from the prevention of the dissolution of NiTSPc and the adsorption of the oxidation product of luminol on the electrode surface. The proposed method enables a detection limit for luminal of 6.0 x 10(-8) mol L(-1) to be achieved in the presence of H(2)O(2) in the neutral solution. The enhanced ECL intensity had a linear relationship with the concentration of luminol in the range of 1.0 x 10(-7)-8.0 x 10(-6) mol L(-1).  相似文献   

9.
Wang K  Dai L  Liu Q  Li H  Ju C  Wu J  Li H 《The Analyst》2011,136(20):4344-4349
We report a novel and facile electrodeposition method to fabricate a nano-structure film of the unsubstituted metal phthalocyanine on a glassy carbon electrode (GCE). In this electrodeposition system, unsubstituted iron(II) phthalocyanine (u-FePc) was chosen as the model complex of the unsubstituted metalphthalocyanine, and the ionic liquid 1-octyl-3-methylimidazolium trifluoroacetate was employed as the solvent and electrolyte, thus avoiding the use of additional costly supporting electrolyte. Excellent electrocatalytic performance of the u-FePc nano-structure film was first evaluated by electrocatalytic oxidation of ascorbic acid (AA). Compared with the bare GCE, the oxidation peak potential of AA at u-FePc/GCE shifted negatively about 264 mV, and the oxidation peak current increased about 1.8 times. Furthermore, the as-prepared film was employed for the investigation of luminol electrochemiluminescence (ECL) behavior in neutral solution, which showed excellent performance including under selected experimental conditions, the ECL intensity showing an acceptable linear relationship for luminol concentrations between 5 × 10(-8) and 5 × 10(-6) M, and a linear response to H(2)O(2) over a wide concentration range, from 1.0 × 10(-8) to 1.0 × 10(-5) M in 3.0 μM luminol solution.  相似文献   

10.
Lei R  Xu X  Yu F  Li N  Liu HW  Li K 《Talanta》2008,75(4):1068-1074
Quercetin greatly enhanced luminol electrochemiluminescence of quercetin in alkaline solution. When the concentration of luminol was 0.1 mol L(-1), the detection limit for quercetin was 2.0x10(-8) mol L(-1) with a linear range from 1.0x10(-7) to 2x10(-5) mol L(-1). The pH and buffer substantially affected ECL intensity. Quercetin was autoxidized in alkaline aqueous solution. The rate of autoxidation of quercetin in various pH buffers and borate concentrations were measured. Borate was found to inhibit quercetin autoxidation and compromise quercetin enhancement effect on luminol ECL to some extent. Two final autoxidation products were identified with LC-MS methods. Autoxidation process was associated with enhancement of ECL intensity. The ROS generated during quercetin autoxidation enhanced the ECL intensity.  相似文献   

11.
Cheng L  Deng S  Lei J  Ju H 《The Analyst》2012,137(1):140-144
A novel disposable solid-state electrochemiluminescent (ECL) biosensor was fabricated by immobilizing glucose oxidase and surface-unpassivated CdTe quantum dots (QDs) on a screen-printed carbon electrode (SPCE). The surface morphology of the biosensor was characterized with scanning electron microscopy and atomic force microscopy. With dissolved O(2) as an endogenous coreactant, QDs/SPCE showed strong ECL emission in pH 9.0 HCl-Tris buffer solution with low ECL peak potential at -0.89 V. The ECL intensity was twice that with hydrogen peroxide as coreactant at the same concentration. This phenomenon meant the ECL decreased upon consumption of dissolved O(2) and thus could be applied to the construction of oxidase-based ECL biosensors. With glucose oxidase as a model enzyme, the biosensor showed rapid response to glucose with a linear range of 0.8 to 100 μM and a detection limit of 0.3 μM. Further detection of glucose contained in human serum samples showed acceptable sensitivity and selectivity. This work provided a promising application of QDs in ECL-based disposable biosensors.  相似文献   

12.
在碳纳米管(CNTs)和K3Fe(CN)6修饰的铂电极上吸附固定胆碱氧化酶,以鲁米诺为发光试剂,研制了胆碱电化学发光(ECL)生物传感器.CNTs可有效提高电极表面的电荷传输能力、提高电极表面的生物相容性和对酶分子的固载能力;K3Fe(CN)6对酶活性具有激活作用,同时对H2O2增敏的鲁米诺ECL有增强作用,均有利于提...  相似文献   

13.
An electrochemiluminescent glucose biosensor was proposed based on gold nanoparticle-catalyzed luminol electrochemiluminescence (ECL). Gold nanoparticles were self-assembled onto silica sol–gel network, and then glucose oxidase was adsorbed on the surface of gold nanoparticles. The surface assembly process and the electrochemistry and ECL behaviors of the biosensor were investigated. The assembled gold nanoparticles could efficiently electrocatalyze luminol ECL. ECL intensity of the biosensor depended on scan rate, luminol concentration, and size of gold nanoparticles. The response of the ECL biosensor was linear over the range 1 μM to 5 mM with a detection limit of 0.2 μM glucose and showed satisfying reproducibility, stability and selectivity.  相似文献   

14.
鲁米诺在氧化铟锡玻璃上的电聚合及电化学发光性能研究   总被引:5,自引:0,他引:5  
研究了鲁米诺在氧化铟锡(Indium-tinoxide,ITO)玻璃上的电聚合。通过循环伏安和紫外吸收光谱表征,在酸性条件下可以实现鲁米诺对ITO电极的电聚合修饰,聚合在ITO玻璃表面的鲁米诺保持其良好的电化学发光性能,考察了此修饰电极的性能以及相关因素对聚合膜的电化学发光强度的影响。  相似文献   

15.
The reaction of Ln(NO(3))(3).aq with K(3)[Fe(CN)(6)] or K(3)[Co(CN)(6)] and 2,2'-bipyridine in water led to five one-dimensional complexes: trans-[M(CN)(4)(mu-CN)(2)Ln(H(2)O)(4) (bpy)](n)().XnH(2)O.1.5nbpy (M = Fe(3+) or Co(3+); Ln = Sm(3+), Gd(3+), or Yb(3+); X = 4 or 5). The structures for [Fe(3)(+)-Sm(3+)] (1), [Fe(3)(+)-Gd(3+)] (2), [Fe(3)(+)-Yb(3+)] (3), [Co(3)(+)-Gd(3+)] (4), and [Co(3)(+)-Yb(3+)] (5) have been solved; they crystallize in the triclinic space P1 and are isomorphous. The [Fe(3+)-Sm(3+)] complex is a ferrimagnet, its magnetic studies suggesting the onset of weak ferromagnetic 3-D ordering at 3.5 K. The [Fe(3+)-Gd(3+)] interaction is weakly antiferromagnetic. The isotropic nature of Gd(3+) allowed us to evaluate the exchange interaction (J = 0.77 cm(-)(1)).  相似文献   

16.
We developed an FIA system equipped with a chemiluminescence detector using a mixed chemiluminescence reagent of luminol and 1,10-phenanthroline for the detection of metal ions and metal complexes. The carrier, mixed chemiluminescence reagent comprising luminol, 1,10-phenanthroline, and cethyltrimethylammonium bromide, and H2O2 solutions were fed by corresponding pumps at a definite flow rate. Sample solutions dissolving hematin, [Co(NH3)4(H2O)2]2(SO4)3, CuSO4, NiCl2, K3[Fe(CN)6], and K4[Fe(CN)6] were analyzed as models by the means of the present FIA system. Solutions of hematin, [Co(NH3)4(H2O)2]2(SO4)3, CuSO4, and NiCl2 were detected as positive peaks, as usual. The order of the catalytic activity of these samples for the present chemiluminescence reaction using the mixed chemiluminescence reagent was [Co(NH3)4(H2O)2]2(SO4)3 > hematin > CuSO4 > NiCl2. On the other hand, sample solutions of K3[Fe(CN)6] and K4[Fe(CN)6] were detected as negative peaks and were determined over the ranges of 1 x 10(-8) - 1 x 10(-6) M with a detection limit of 1 x 10(-8) M and 2 x 10(-8) - 4 x 10(-6) M with a detection limit of 2 x 10(-8) M, respectively. Their negative peaks were observed reproducibly with a relative standard deviation of 2 - 5%.  相似文献   

17.
A sensor for H(2)O(2) amperometric detection based on a Prussian Blue (PB) bulk modified carbon screen-printed electrode was developed. It has been optimised with respect to the lowest limit of detection achieved. PB was made chemically by the reaction of FeCl(3) with K(4)[Fe(CN)(6)]. The resulting powder, obtained by forced crystallisation induced by acetone, was dried and activated at 150 degrees C for 10 h. PB microparticles (<38 mum) were prepared and mixed with carbon ink. The limit of detection achieved was 0.4 muM with the linear range up to 100 muM of H(2)O(2) with the sensitivity of 137 muA mM(-1) cm(-2), that was comparable with sensors based on electrodeposited PB film. The transducer was applied for a glucose biosensor, that exhibited LOD of 0.22 mM, linear range up to 3 mM, K(M)(app) of 4.6 mM, and the sensitivity of 3.21+/-0.16 muA mM(-1) cm(-2). The peroxide sensor, as well as the glucose biosensor, were totally insensitive to oxygen, ascorbate, urate, and paracetamol.  相似文献   

18.
Qin X  Lu W  Luo Y  Chang G  Asiri AM  Al-Youbi AO  Sun X 《The Analyst》2012,137(4):939-943
The present paper reports on the first preparation of 2,4,6-tris(2-pyridyl)-1,3,5-triazine nanobelts (TPTNBs) by adjusting the pH value of the solution and the subsequent synthesis of Ag nanoparticle (AgNP)-decorated TPTNBs (AgNP-TPTNBs) by mixing an aqueous AgNO(3) solution with preformed TPTNBs without use of any external reducing agent. It is found that the resultant AgNP-TPTNBs exhibit notable catalytic performance for H(2)O(2) reduction. A glucose biosensor was fabricated by immobilizing glucose oxidase (GOD) onto a AgNP-TPTNBs-modified glassy carbon electrode (GCE) for glucose detection. The constructed glucose sensor has a wide linear response range from 3 mM to 20 mM (r: 0.999) with a detection limit of 190 μM. It is further shown that this glucose biosensor can be used for glucose detection in human blood serum.  相似文献   

19.
Chiang MT  Lu MC  Whang CW 《Electrophoresis》2003,24(17):3033-3039
A simple and cost-effective electrochemiluminescence (ECL) detector for capillary electrophoresis (CE) has been developed. The detector was constructed by vertically gluing a 0.5 mL plastic sample vial onto a piece of 1.5 cm x 1 cm x 0.6 mm indium/tin oxide (ITO)-coated glass plate. End-column ECL detection was performed in a wall-jet configuration. Potential control of the ITO electrode was provided using a direct current (DC) battery. Tris(2,2'-bipyridyl)ruthenium(III) (Ru(bpy)3(3+))-based ECL reaction was used for sensitive detection of four trialkylamines (trimethylamine, triethylamine, tripropylamine, tributylamine) and two amino acids (proline, hydroxyproline). With 15 mM sodium borate (pH 9.5) plus 3.5 mM Ru(bpy)3(2+) present in the detection cell and the ITO electrode biased at 1.7 V (vs. platinum wire reference), the test analytes can be efficiently separated and sensitively detected by the developed CE-ECL system. Linearity (r > or = 0.995) over two orders of magnitude and an average number of theoretical plates of 160 000/m were generally obtained. Reproducibility on peak height and migration times (n = 42) was 3.3% and 1.2% for tripropylamine, and 2.4% and 1.5% for proline, respectively. The detection limits were in the range of 2-5 microM (1-2 fmol) for the test analytes.  相似文献   

20.
Cao X  Wang N 《The Analyst》2011,136(20):4241-4246
Fe(2)O(3) was generally considered to be biologically and electrochemically inert, and its electrocatalytic functionality has been rarely realized directly in the past. In this work, Fe(2)O(3) nanowire arrays were synthesized and electrochemically characterized. The as prepared Fe(2)O(3) nanomaterial was proved to be an ideal electrode material due to the intrinsic peroxidase-like catalytic activity. The Fe(2)O(3) nanowire array modified glucose sensor exhibited excellent biocatalytic performance towards the oxidation of glucose with a response time of <6 s, a linear range between 0.015-8 mM, and sensitivity of 726.9 μA mM(-1)cm(-1). Additionally, a high sensing selectivity towards glucose oxidation in the presence of ascorbic acid (AA) and dopamine (DA) has also been obtained at their maximum physiological concentrations, which makes the Fe(2)O(3) nanomaterial promising for the development of effective electrochemical sensors for practical applications.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号