首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
《Electroanalysis》2004,16(20):1653-1659
Detection techniques for biosensors often require bulky instruments or cells that are not feasible for in‐field analysis. Our single‐drop cell design, optimized in this work, comprised a screen‐printed three‐electrode (SPE), strip in horizontal position onto which a volume of 100 μL of sample or substrate solution was placed to ensure electrical contact (complete circuit). Together with optimized linear sweep voltammetry (LSV), parameters for the detection of the enzyme alkaline phosphatase (AP), the system was applied to a biosensor for the analysis of polycyclic aromatic hydrocarbons (PAHs), in environmental samples. A limit of detection (LOD), of 0.15 ppb was achieved for a model system with an IC50 value of 0.885 ppb and a linear range (LR), of 0.2–10 ppb. Application of the single drop analysis (SDA), format to a PAH biosensor gave a LOD of 1.4 ppb for detection of phenanthrene with an IC50 value of 29.3 ppb and linear range of 2–100 ppb. Proof of concept is shown with spiked sample analysis of phenanthrene in matrices such as sea, river and tap water.  相似文献   

2.
In recent years, a number of approaches have emerged that enable far‐field fluorescence imaging beyond the diffraction limit of light, namely super‐resolution microscopy. These techniques are beginning to profoundly alter our abilities to look at biological structures and dynamics and are bound to spread into conventional biological laboratories. Nowadays these approaches can be divided into two categories, one based on targeted switching and readout, and the other based on stochastic switching and readout of the fluorescence information. The main prerequisite for a successful implementation of both categories is the ability to prepare the fluorescent emitters in two distinct states, a bright and a dark state. Herein, we provide an overview of recent developments in super‐resolution microscopy techniques and outline the special requirements for the fluorescent probes used. In combination with the advances in understanding the photophysics and photochemistry of single fluorophores, we demonstrate how essentially any single‐molecule compatible fluorophore can be used for super‐resolution microscopy. We present examples for super‐resolution microscopy with standard organic fluorophores, discuss factors that influence resolution and present approaches for calibration samples for super‐resolution microscopes including AFM‐based single‐molecule assembly and DNA origami.  相似文献   

3.
Accurate quantification of the copy numbers of noncoding RNA has recently emerged as an urgent problem, with impact on fields such as RNA modification research, tissue differentiation, and others. Herein, we present a hybridization‐based approach that uses microscale thermophoresis (MST) as a very fast and highly precise readout to quantify, for example, single tRNA species with a turnaround time of about one hour. We developed MST to quantify the effect of tRNA toxins and of heat stress and RNA modification on single tRNA species. A comparative analysis also revealed significant differences to RNA‐Seq‐based quantification approaches, strongly suggesting a bias due to tRNA modifications in the latter. Further applications include the quantification of rRNA as well as of polyA levels in cellular RNA.  相似文献   

4.
Three fluorescent BINOL-Si complexes (FS1, FS2 and FS3) were rationally designed and synthesized to detect diethyl chlorophosphate (DCP), a mimic of lethal nerve agents. These three fluorescent probes showed green, yellow and orange fluorescence, respectively. Moreover, the series of fluorescent probes has the characteristics of fast response time (≤4 s), low detection limit (0.0097 μmol/L), high sensitivity and naked eye detection. More important, a fiber optic sensor capable of detecting DCP vapor in real time was also prepared for the first time, the lowest detection limits (down to 4.4 ppb) were all lower than that of the IDLH (immediately dangerous to life or health) concentration of Sarin (7.0 ppb).  相似文献   

5.
《中国化学快报》2020,31(11):2960-2964
Three fluorescent BINOL-Si complexes (FS1, FS2 and FS3) were rationally designed and synthesized to detect diethyl chlorophosphate (DCP), a mimic of lethal nerve agents. These three fluorescent probes showed green, yellow and orange fluorescence, respectively. Moreover, the series of fluorescent probes has the characteristics of fast response time (≤ 4 s), low detection limit (0.0097 μmol/L), high sensitivity and naked eye detection. More important, a fiber optic sensor capable of detecting DCP vapor in real time was also prepared for the first time, the lowest detection limits (down to 4.4 ppb) were all lower than that of the IDLH (immediately dangerous to life or health) concentration of Sarin (7.0 ppb).  相似文献   

6.
Bisphenol A (BPA) is an environmental endocrine‐disrupting chemicals that is widely used in common consumer products. There is an increasing concern regarding human exposure to BPA owing to the potential adverse effects associated with its estrogenic activity. For assessing environmental exposure to BPA, it is essential to have a sensitive, accurate and selective analytical method, especially one that can detect low BPA levels in complex sample matrices. In this study, we developed and validated an accurate, sensitive, and robust liquid chromatography–tandem mass spectrometry method for simultaneous quantification of free BPA and BPA β‐d ‐glucuronide (BPA‐gluc) concentrations in human urine with only a single injection. Calibration curves were linear over a concentration range of 1–100 ng/mL for BPA and 10–1000 ng/mL for BPA‐gluc. The levels of the analytes were determined quantitatively with HPLC/ESI‐MS/MS by using negative electrospray ionization in the select ion monitoring mode and a pentaflouraphenyl propyl column. The validated method was applied to the analysis of spot urine specimens collected from randomly selected healthy human subjects. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

7.
We present a fast and sensitive nanosensor that can detect organic mercury, exploiting the combination of the catalytic and plasmonic properties of gold nanoparticles (AuNPs). The method is one‐step and completely instrument‐free, and has a colorimetric readout clearly detectable by simple visual inspection. The AuNPs catalyze efficient organic mercury reduction to the metallic form (Hg0), allowing its nucleation and amalgam formation on particle surface, with consequent aggregation‐induced plasmon shift. This leads to very rapid (1 min) and specific colorimetric detection of mercury species. The achieved limit of detection (20 ppb) is compliant with current regulatory limits in food.  相似文献   

8.
Building‐related health effects are frequently observed. Several factors have been listed as possible causes including temperature, humidity, light conditions, presence of particulate matter, and microorganisms or volatile organic compounds. To be able to link exposure to specific volatile organic compounds to building‐related health effects, powerful and comprehensive analytical methods are required. For this purpose, we developed an active air sampling method that utilizes dual‐bed tubes loaded with TENAX‐TA and Carboxen‐1000 adsorbents to sample two parallel air samples of 4 L each. For the comprehensive volatile organic compounds analysis, an automated thermal desorption comprehensive two‐dimensional gas chromatography high‐resolution time‐of‐flight mass spectrometry method was developed and used. It allowed targeted analysis of approximately 90 known volatile organic compounds with relative standard deviations below 25% for the vast majority of target volatile organic compounds. It also allowed semiquantification (no matching standards) of numerous nontarget air contaminants using the same data set. The nontarget analysis workflow included peak finding, background elimination, feature alignment, detection frequency filtering, and tentative identification. Application of the workflow to air samples from 68 indoor environments at a large hospital complex resulted in a comprehensive volatile organic compound characterization, including 178 single compounds and 13 hydrocarbon groups.  相似文献   

9.
Polymer modification through silane grafting and its subsequent crosslinking allows the rheological properties of a polymer to be tuned from those of a viscous melt to those of a crosslinked elastic network. In this study, a metallocene polyolefin resin is grafted with vinyl trimethoxy silane (VTMS) using dicumyl peroxide (DCP) as the initiator and is subsequently crosslinked in an oxidative environment. Dynamic rheological experiments are conducted to elucidate the effects of DCP and VTMS concentrations on the grafting and ensuing crosslinking processes. We find that the addition of VTMS alone to the polymer produces no grafting. In contrast, the presence of DCP by itself leads to direct crosslinking between polymer chains as suggested by an increase in elastic modulus and complex viscosity. Samples containing both DCP and VTMS undergo silane grafting, with the extent of grafting increasing with increasing DCP concentration. This conclusion is borne out by both rheological and Fourier transform infrared measurements. The grafted samples undergo silane crosslinking only in an oxidative environment and at temperatures equal to or greater than 190 °C. During crosslinking, the samples undergo a transition from a viscous melt with frequency‐dependent moduli to a gel exhibiting frequency‐independent moduli with the elastic modulus exceeding the viscous modulus. However, the kinetics of crosslinking and the extent of the modulus increase are a function of the DCP concentration, with both exhibiting a maximum at a specific DCP and VTMS combination. © 2000 John Wiley & Sons, Inc. J Polym Sci B: Polym Phys 38: 2468–2479, 2000  相似文献   

10.
《Electroanalysis》2017,29(3):686-695
In this work, we report on the determination of trace manganese (Mn) using cathodic stripping voltammetry (CSV) using a microfabricated sensor with a Pt thin‐film working electrode. While an essential trace metal for human health, prolonged exposure to Mn tends to gradually impair our neurological system. The potential sources of Mn exposure make it necessary to monitor the concentration in various sample matrices. Previous work by us and others suggested CSV as an effective method for measuring trace Mn. The analytical performance metrics were characterized and optimized, leading to a calculated limit of detection (LOD) of 16.3 nM (0.9 ppb) in pH 5.5, 0.2 M acetate buffer. Further, we successfully validated Mn determination in surface water with ∼90% accuracy and >97% precision as compared with inductively coupled plasma mass spectrometry (ICP‐MS) “gold standard” measurement. Ultimately, with stable, accurate and precise electrochemical performance, this Pt sensor permits rapid monitoring of Mn in environmental samples, and could potentially be used for point‐of‐use measurements if coupled with portable instrumentation.  相似文献   

11.
Polymer containing chalcone moiety showed a cis–trans isomerism. Two novel acrylate monomers, 4‐[3‐(2,4‐dichloro‐phenyl)3‐oxoprop‐1‐en‐1‐yl]phenylacrylate (DCP) and 4‐(3‐(4‐((4‐(4‐(3‐(2,4‐dichlorophenyl)‐3‐oxoprop‐1‐en‐1‐yl)phenoxy)‐6‐((4‐nitrophenyl)amino)‐1,3,5‐triazin‐2‐yl)oxy)phenyl)‐3‐oxoprop‐1‐en‐1‐yl)phenyl acrylate (TCP) were synthesized and copolymer with acrylic acid. All the monomers and polymer were characterized by IR, NMR and UV techniques. The Mw of the DCP based polymer and TCP based polymer were 4000 and 10,000 g/mol respectively. DCP and TCP based polymer showed double stage and single stage decomposition respectively. The reactivity ratio of the polymers showed that the poly(DCP‐co‐AA) formed random polymerization whereas poly(TCP‐co‐AA) formed alternate copolymerization. The poly(TCP‐co‐AA) showed excellent photoisomerism whereas poly(DCP‐co‐AA) showed photocycloaddition reaction. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

12.
《Electroanalysis》2017,29(2):514-520
A long‐life electrochemical sensor for the continuous analysis of heavy metal ions (Zn(II), Cd(II), Pb(II), Cu(II), and Hg(II)) was developed using the graphene oxide (GO) anchored‐functionalized polyterthiophene (poly[3′‐(2‐aminopyrimidyl)‐2,2′:5′,2′′‐terthiophene], polyPATT) composite. The PATT monomer was synthesized and polymerized with GO to form the composite using a potential cycling method, followed by Nafion coating. The modified sensor surface was characterized employing electrochemical and surface analysis methods. Experimental variables affecting the analytical performance were optimized. Interference effects of other metal ions having similar redox potentials were also investigated. The performance of chronocoulometry (CC) without predeposition was compared with the results of square wave anodic stripping voltammetry (SWASV) with predeposition. The dynamic range of CC for the target ions were between 1 ppb and 10 ppm, respectively with the detection limits between 0.05 (±0.05) and 0.20 (±0.15) ppb for the CC method without predeposition, and between 0.08 (±0.05) and 0.30 (±0.12) ppb for the SWASV with 300 sec of deposition time (n=3 ). The reliability of the method was evaluated by continuously analysing environmental water samples using a single sensor probe in a flow system for 93 days.  相似文献   

13.
《Electrophoresis》2018,39(19):2431-2438
Dispersive liquid–liquid microextraction (DLLME) coupled with CE was developed for simultaneous determination of five types of chlorophenols (CPs), namely 2‐chlorophenol (2‐CP), 4‐chlorophenol (4‐CP), 2,4‐dichlorophenol (2,4‐DCP), 2,6‐dichlorophenol (2,6‐DCP), and 2,4,6‐trichlorophenol (2,4,6‐TCP) in water samples. Several parameters affecting DLLME and CE conditions were systematically investigated. Under the optimized DLLME‐CE conditions, the five CPs were separated completely within 7.5 min and good enrichment factors were obtained of 40, 193, 102, 15, and 107 for 4‐CP, 2,4,6‐TCP, 2,4‐DCP, 2‐CP, and 2,6‐DCP, respectively. Good linearity was attained in the range of 1–200 μg/L for 2,4,6‐TCP, 2,4‐DCP, 2−300 μg/L for 4‐CP and 2‐CP, and 1−300 μg/L for 2,6‐DCP, with correlation coefficients (r) over 0.99. The LOD (S/N = 3) and the LOQ (S/N = 10) were 0.31−0.75 μg/L and 1.01−2.43 μg/L, respectively. Recoveries ranging from 60.85 to 112.36% were obtained with tap, lake, and river water spiked at three concentration levels and the RSDs (for n = 3) were 1.31–11.38%. With the characteristics of simplicity, cost‐saving, and environmental friendliness, the developed DLLME‐CE method proved to be potentially applicable for the rapid, sensitive, and simultaneous determination of trace CPs in complicated water samples.  相似文献   

14.
Single‐molecule force spectroscopy based on atomic force microscopy (AFM‐SMFS) has allowed the measurement of the intermolecular forces involved in protein‐protein interactions at the molecular level. While intramolecular interactions are routinely identified directly by the use of polyprotein fingerprinting, there is a lack of a general method to directly identify single‐molecule intermolecular unbinding events. Here, we have developed an internally controlled strategy to measure protein–protein interactions by AFM‐SMFS that allows the direct identification of dissociation force peaks while ensuring single‐molecule conditions. Single‐molecule identification is assured by polyprotein fingerprinting while the intermolecular interaction is reported by a characteristic increase in contour length released after bond rupture. The latter is due to the exposure to force of a third protein that covalently connects the interacting pair. We demonstrate this strategy with a cohesin–dockerin interaction.  相似文献   

15.
A sensitive method of CZE‐ultraviolet (UV) detection based on the on‐line preconcentration strategy of field‐amplified sample injection (FASI) was developed for the simultaneous determination of five kinds of chlorophenols (CPs) namely 4‐chlorophenol (4‐CP), 2‐chlorophenol (2‐CP), 2,4‐dichlorophenol (2,4‐DCP), 2,4,6‐trichlorophenol (2,4,6‐TCP), and 2,6‐dichlorophenol (2,6‐DCP) in water samples. Several parameters affecting CZE and FASI conditions were systematically investigated. Under the optimal conditions, sensitivity enhancement factors for 4‐CP, 2‐CP, 2,4‐DCP, 2,4,6‐TCP, and 2,6‐DCP were 9, 27, 35, 43, and 43 folds, respectively, compared with the direct CZE, and the baseline separation was achieved within 5 min. Then, the developed FASI‐CZE‐UV method was applied to tap and lake water samples for the five CPs determination. The LODs (S/N = 3) were 0.0018–0.019 µg/mL and 0.0089–0.029 µg/mL in tap water and lake water, respectively. The values of LOQs in tap water (0.006–0.0074 µg/mL) were much lower than the maximum permissible concentrations of 2,4,6‐TCP, 2,4‐DCP, and 2‐CP in drinking water stipulated by World Health Organization (WHO) namely 0.3, 0.04, and 0.01 µg/mL, respectively, and thereby the method was suitable to detect the CPs according to WHO guidelines. Furthermore, the method attained high recoveries in the range of 83.0–119.0% at three spiking levels of five CPs in the two types of water samples, with relative standard deviations of 0.37–8.58%. The developed method was proved to be a simple, sensitive, highly automated, and efficient alternative to CPs determination in real water samples.  相似文献   

16.
Ethylene propylene diene rubber‐fullerene (EPDM/C60) composite, partially crosslinked by ultraviolet (UV) radiation, was prepared and characterized for crosslink density, mechanical properties and thermal behavior. FT‐IR analysis showed peak disappearance at 1688 cm?1, corresponding to the unsaturation of EPDM, and the appearance of new peaks relating to the formation of oxidation products of C60, such as epoxide, keto, aldehyde and carboxylic groups. Solubility studies demonstrated the dissolution of pristine EPDM in toluene even after a longer period of UV exposure, whereas EPDM/C60 composite became insoluble and/or swollen after 6 hr of UV exposure, indicating the formation of partial crosslinking between EPDM and C60. Differential scanning calorimetry (DSC) measurements revealed an increase in the glass transition temperature peak of UV‐cured EPDM. Thermogravimetric analysis (TGA) showed that UV exposure reduced the thermal decomposition temperature of EPDM/C60, pristine EPDM and dicumyl peroxide (DCP)‐cured EPDM. The modulus, tensile stress and elongation at break of EPDM/C60 composites were greatly influenced by the duration of UV irradiation. Comparison of UV‐cured EPDM/C60 composite with DCP‐cured EPDM confirmed the superior strength properties of the former system. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

17.
Redox reactions are central to energy conversion and life metabolism. Herein we present electrochemical measurements with fluorescent readout of the redox‐sensitive dye Methylene Blue (MB), at the single‐molecule (SM) level. To overcome the low fluorescence quantum yield of MB we enhanced fluorescence by using individual gold nanorods to achieve the required sensitivity. By measuring the same molecule at different electrochemical potentials we determined the mid‐point potential of each single molecule through its redox‐induced fluorescence blinking dynamics.  相似文献   

18.
Electroanalytical methods can be used for the reliable detection of the toxic heavy metal lead in drinking water samples. Inkjet printed electrodes have potential for the rapid and affordable assessment of drinking water. Researchers have shown the electrochemical sensing applicability of inkjet printed electrodes. In this work, Pb2+ was detected using an inkjet printed multi‐walled carbon nanotube (IJP‐MW‐CNT) electrode with silver tracks printed underneath. The silver tracks provide the sensor with the conductivity needed for sensitive measurements. MW‐CNT were dispersed in water using bile salts as a surfactant to prepare the ink. The IJP‐MW‐CNT electrode was used as the working electrode with a platinum wire and Ag/AgCl as auxiliary and reference electrode, respectively. The electrodes performance was optimized in 0.1 M acetate buffer (pH=4.3) and had two linear ranges of 5 to 20 ppb (R2=0.99) with a sensitivity of 38 nA/ppb and 20 to 50 ppb (R2=0.98) with a sensitivity of 15 nA/ppb and a limit of detection (LOD) of 1.0 ppb for Pb2+. The analytical applicability of electrode was determined by constructing a calibration curve in an unaltered drinking water sample (i. e.) Cincinnati tap water with two linear ranges of 15 to 40 ppb (R2=0.99) with a sensitivity of 1.5 nA/ppb and 40 to 70 ppb (R2=0.99) with a sensitivity of 3.5 nA/ppb and a LOD of 1.0 ppb for Pb2+. Effects of copper and cadmium as potential interferents are reported.  相似文献   

19.
Gas chromatography (GC) has been interfaced very simply and inexpensively with a flame photometric detector (FPD) and a direct current plasma (DCP) atomic emission spectrometer in order to perform highly specific and selective determination of organotins in fish and shellfish samples. GC–FPD studies employed a fused-silica, megabore column with a thin, immobilized stationary phase of DB-17 (1 μm thickness), with a commercially available GC–FPD instrument. No prior alkylation or hydridization reactions were performed on the organotins; rather they were separated as the original, native species. Separate GC–FPD and GC–DCP injections and quantitative determinations have been performed, though simultaneous FPD/DCP detection on a single injection is suggested. This permitted routine qualitative and quantitative determinations of organotin species in complex food matrices (fish/shellfish) via both element selective detectors. Isothermal GC–FPD/DCP conditions permitted baseline resolution of all four tin species of interest today: monobutyl-, dibutyl-, tributyl- (TBT), and tetrabutyl-tin. Optimization of the GC–DCP interface was accomplished, followed by a determination of detection limits and linearity of the calibration plots, and a comparison of the results with those obtained by the newer GC–FPD approach (which was also developed here). In three sample instances, qualitative and quantitative results for naturally occurring and spiked levels agreed for both the GC–FPD and GC–DCP approaches. Improved sample preparation and extraction procedures have been developed for organotins from fish samples involving extraction with an organic solvent, concentration, saponification, back-extraction, and injection of the eluent onto the GC column. Quantitative levels of organotins (solely TBT) in fish and shellfish are reported for samples from Europe, Korea, Scandinavia, and the USA.  相似文献   

20.
A simple method for benzene, toluene, and xylenes (BTX) quantitative analyses in human urine was developed, using headspace solid-phase microextraction (HS-SPME) and gas chromatography coupled to mass spectrometry detection in the single ion monitoring mode. The developed method is solventless, non-invasive, requires small volume of sample (1 ml), shows high selectivity, sensitivity, repeatability, and linearity (correlation coefficients >0.998), providing a useful alternative to assess human exposure to BTX compounds due to occupational reasons or eventual exposure to organic solvents. Detection limit varies from 0.28 to 0.5 ppb (v/v).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号