首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Xu C  Wang M  Yin X 《The Analyst》2011,136(19):3877-3883
A simple three-dimensional (3D) hydrodynamic focusing microfluidic device integrated with continuous sampling, rapid dynamic lysis, capillary electrophoretic (CE) separation and detection of intracellular content is presented. One of the major difficulties in microfluidic cell analysis for adherent cells is that the cells are prone to attaching to the channel surface. To solve this problem, a cross microfluidic chip with three sheath-flow channels located on both sides of and below the sampling channel was developed. With the three sheath flows around the sample solution-containing cells, the formed soft fluid wall prevents the cells from adhering to the channel surface. Labeled cells were 3D hydrodynamically focused by the sheath-flow streams and smoothly introduced into the cross-section one by one. The introduction of sheath-flow streams not only ensured single-cell sampling but avoided blockage of the sampling channel by adherent cells as well. The maximum rate for introduction of individual cells into the separation channel was about 151 cells min(-1). With electric field applied on the separation channel, the aligned cells were driven into the separation channel and rapidly lysed within 400 ms at the entry of the channel by sodium dodecylsulfate (SDS) added in the sheath-flow solution. The microfluidic system was evaluated by analysis of reduced glutathione (GSH) and reactive oxygen species (ROS) in single HepG2 cells. The average analysis throughput of ROS and GSH in single cells was 16-18 cells min(-1).  相似文献   

2.
Hydrodynamic focusing—a versatile tool   总被引:1,自引:0,他引:1  
The control of hydrodynamic focusing in a microchannel has inspired new approaches for microfluidic mixing, separations, sensors, cell analysis, and microfabrication. Achieving a flat interface between the focusing and focused fluids is dependent on Reynolds number and device geometry, and many hydrodynamic focusing systems can benefit from this understanding. For applications where a specific cross-sectional shape is desired for the focused flow, advection generated by grooved structures in the channel walls can be used to define the shape of the focused flow. Relative flow rates of the focused flow and focusing streams can be manipulated to control the cross-sectional area of the focused flows. This paper discusses the principles for defining the shape of the interface between the focused and focusing fluids and provides examples from our lab that use hydrodynamic focusing for impedance-based sensors, flow cytometry, and microfabrication to illustrate the breadth of opportunities for introducing new capabilities into microfluidic systems. We evaluate each example for the advantages and limitations integral to utilization of hydrodynamic focusing for that particular application.  相似文献   

3.
This paper describes a micro flow cytometer system designed for efficient and non-damaging analysis of samples with small numbers of precious cells. The system utilizes actuation of Braille-display pins for micro-scale fluid manipulation and a fluorescence microscope with a CCD camera for optical detection. The microfluidic chip is fully disposable and is composed of a polydimethylsiloxane (PDMS) slab with microchannel features sealed against a thin deformable PDMS membrane. The channels are designed with diffusers to alleviate pulsatile flow behaviors inherent in pin actuator-based peristaltic pumping schemes to maximize hydrodynamic focusing of samples with minimal disturbances in the laminar streams within the channel. A funnel connected to the microfluidic channel is designed for efficient loading of samples with small number of cells and is also positioned on the chip to prevent physical damages of the samples by the squeezing actions of Braille pins during actuation. The sample loading scheme was characterized by both computational fluidic dynamics (CFD) simulation and experimental observation. A fluorescein solution was first used for flow field investigation, followed by use of fluorescence beads with known relative intensities for optical detection performance calibration. Murine myoblast cells (C2C12) were exploited to investigate cell viability for the sample loading scheme of the device. Furthermore, human promyelocytic leukemia (HL60) cells stained by hypotonic DNA staining buffer were also tested in the system for cell cycle analysis. The ability to efficiently analyze cellular samples where the number of cells is small was demonstrated by analyzing cells from a single embryoid body derived from mouse embryonic stem cells. Consequently, the designed microfluidic device reported in this paper is promising for easy-to-use, small sample size flow cytometric analysis, and has potential to be further integrated with other Braille display-based microfluidic devices to facilitate a multi-functional lab-on-a-chip for mammalian cell manipulations.  相似文献   

4.
Precise cell detecting and counting is meaningful in circulating tumor cells (CTCs) analysis. In this work, a simple cyclic olefin copolymer (COC) microflow cytometer device was developed for size-resolved CTCs counting. The proposed device is constructed by a counting channel and a pinched injection unit having three channels. Through injection flow rate control, microspheres/cells can be focused into the centerline of the counting channel. Polystyrene microspheres of 3, 9, 15, and 20 µm were used for the microspheres focusing characterization. After coupling to laser-induced fluorescence detection technique, the proposed device was used for polystyrene microspheres counting and sizing. A count accuracy up to 97.6% was obtained for microspheres. Moreover, the proposed microflow cytometer was applied to CTCs detecting and counting. To mimic blood sample containing CTCs and CTCs mixture with different subtypes, an MDA-MB-231 (human breast cell line) spiked red blood cells sample and a mixture of MDA-MB-231 and MCF-7 (human breast cell line) sample were prepared, respectively, and then analyzed by the developed pinched flow-based microfluidic cytometry. The simple fabricated and easy operating COC microflow cytometer exhibits the potential in the point-of-care clinical application.  相似文献   

5.
A microfabricated flow cytometer has been developed that is capable of detecting nearly all of the microparticles in an aqueous suspension. Current design allows for integrated coupling between an optical fiber-based detection system and the particle stream via hydrodynamic focusing. By adjusting the relative flow-rates at the auxiliary inputs of the focusing manifold, the particle stream can be steered out-of-plane relative to the illuminating laser, and similarly the particle stream can be squeezed or expanded. The microfabricated device was constructed in polydimethylsiloxane with cross-sectional microfluidic dimensions of 125 μm×125 μm. Using the present device and method, fluorescent microparticles in aqueous solution were counted at an absolute counting efficiency of 91±4%. The coefficient of variation of the fluorescence pulse-heights for far-red fluorescent microparticles was 15%. The device exhibited a linear response to fluorescence intensity calibration microparticles as shown by comparison with a commercial cytometer instrument.  相似文献   

6.
In recent years, researchers are paying the increasing attention to the development of portable microfluidic diagnostic devices including microfluidic flow cytometry for the point‐of‐care testing. Microfluidic flow cytometry, where microfluidics and flow cytometry work together to realize novel functionalities on the microchip, provides a powerful tool for measuring the multiple characteristics of biological samples. The development of a portable, low‐cost, and compact flow cytometer can benefit the health care in underserved areas such as Africa or Asia. In this article, we review recent advancements of microfluidics including sample pumping, focusing and sorting, novel detection approaches, and data analysis in the field of flow cytometry. The challenge of microfluidic flow cytometry is also examined briefly.  相似文献   

7.
Polyimide-based microfluidic devices   总被引:1,自引:0,他引:1  
This paper describes the development of polyimide-based microfluidic devices. A layer transfer and lamination technique is used to fabricate flexible microfluidic channels in various shapes and with a wide range of dimensions. High bond strengths can be achieved by cure cycle adaptation and surface treatment of the polyimide layers prior to bonding. The polyimide microchannels can be combined with metallization layers to fabricate electrodes inside and outside channels. The resulting devices can be used for flexible fluidic and electrical connectors, implantable fluid delivery devices, microelectrodes with embedded fluidic channels, chip-based flow cytometry and for a great variety of other applications in medical, chemical or biological research.  相似文献   

8.
Zhuang G  Jensen TG  Kutter JP 《Electrophoresis》2012,33(12):1715-1722
In this paper, we describe a microfluidic device composed of integrated microoptical elements and a two-layer microchannel structure for highly sensitive light scattering detection of micro/submicrometer-sized particles. In the two-layer microfluidic system, a sample flow stream is first constrained in the out-of-plane direction into a narrow sheet, and then focused in-plane into a small core region, obtaining on-chip three-dimensional (3D) hydrodynamic focusing. All the microoptical elements, including waveguides, microlens, and fiber-to-waveguide couplers, and the in-plane focusing channels are fabricated in one SU-8 layer by standard photolithography. The channels for out-of-plane focusing are made in a polydimethylsiloxane (PDMS) layer by a single cast using a SU-8 master. Numerical and experimental results indicate that the device can realize 3D hydrodynamic focusing reliably over a wide range of Reynolds numbers (0.5 < Re < 20). Polystyrene particles of three sizes (2, 1, and 0.5 μm) were measured in the microfluidic device with integrated optics, demonstrating the feasibility of this approach to detect particles in the low micrometer size range by light scattering detection.  相似文献   

9.
The sensitivity of a microfluidic impedance flow cytometer is governed by the dimensions of the sample analysis volume. A small volume gives a high sensitivity, but this can lead to practical problems including fabrication and clogging of the device. We describe a microfluidic impedance cytometer which uses an insulating fluid to hydrodynamically focus a sample stream of particles suspended in electrolyte, through a large sensing volume. The detection region consists of two pairs of electrodes fabricated within a channel 200 μm wide and 30 μm high. The focussing technique increases the sensitivity of the system without reducing the dimensions of the microfluidic channel. We demonstrate detection and discrimination of 1 μm and 2 μm diameter polystyrene beads and also Escherichia coli. Impedance data from single particles are correlated with fluorescence emission measured simultaneously. Data are also compared with conventional flow cytometry and dynamic light scattering: the coefficient of variation (CV) of size is found to be comparable between the systems.  相似文献   

10.
This paper describes a method to create stable chemical gradients without requiring fluid flow. The absence of fluid flow makes this device amenable to cell signaling applications where soluble factors can impact cell behavior. This device consists of a membrane-covered source region and a large volume sink region connected by a microfluidic channel. The high fluidic resistance of the membrane limits fluid flow caused by pressure differences in the system, but allows diffusive transport of a chemical species through the membrane and into the channel. The large volume sink region at the end of the microfluidic channel helps to maintain spatial and temporal stability of the gradient. The chemical gradient in a 0.5 mm region near the sink region experiences a maximum of 10 percent change between the 6 and 24 h data points. We present the theory, design, and characterization of this device and provide an example of neutrophil chemotaxis as proof of concept for future quantitative cell-signaling applications.  相似文献   

11.
We describe a microfluidic cytometer that performs simultaneous optical and electrical characterisation of particles. The microfluidic chip measures side scattered light, signal extinction and fluorescence using integrated optical fibres coupled to photomultiplier tubes. The channel is 80 μm high and 200 μm wide, and made from SU-8 patterned and sandwiched between glass substrates. Particles were focused into the analysis region using 1-D hydrodynamic focusing and typical particle velocities were 0.1 ms(-1). Excitation light is coupled into the detection channel with an optical fibre and focused into the channel using an integrated compound air lens. The electrical impedance of particles is measured at 1 MHz using micro-electrodes fabricated on the channel top and bottom. This data is used to accurately size the particles. The system is characterised using a range of different sized polystyrene beads (fluorescent and non-fluorescent). Single and mixed populations of beads were measured and the data compared with a conventional flow cytometer.  相似文献   

12.
A four-electrode impedance-based microfluidic device has been designed with tunable sensitivity for future applications to the detection of pathogens and functionalized microparticles specifically bound to molecular recognition molecules on the surface of a microfluidic channel. In order to achieve tunable sensitivity, hydrodynamic focusing was employed to confine the electric current by simultaneous introduction of two fluids (high- and low-conductivity solutions) into a microchannel at variable flow-rate ratios. By increasing the volumetric flow rate of the low-conductivity solution (sheath fluid) relative to the high-conductivity solution (sample fluid), increased focusing of the high-conductivity solution over four coplanar electrodes was achieved, thereby confining the current during impedance interrogation. The hydrodynamic and electrical properties of the device were analyzed for optimization and to resolve issues that would impact sensitivity and reproducibility in subsequent biosensor applications. These include variability in the relative flow rates of the sheath and sample fluids, changes in microchannel dimensions, and ionic concentration of the sample fluid. A comparative analysis of impedance measurements using four-electrode versus two-electrode configurations for impedance measurements also highlighted the advantages of using four electrodes for portable sensor applications.
A four-electrode sensor with hydrodynamic focusing to confine that the current was characterized for tunable sensitivity  相似文献   

13.
Kang YJ  Yang S 《Lab on a chip》2012,12(10):1881-1889
Fluctuations in flow rate invariably occur in microfluidic devices. This fluidic instability results in a deteriorating performance and the suspension of their unique functions occasionally. In this study, a fluidic-LPF (low pass filter), which is composed of an ACU (air compliance unit) and a FCSP (fluidic channel with high fluidic resistance for sufficient preload), has been proposed for providing the stabilization of hydrodynamic flow in microfluidic devices. To investigate the characteristics of various fluidic networks including our fluidic-LPF, we used a parametric identification method to estimate the time constants via a transient response that was based on a discrete parameter model. In addition, we propose the use of a pulsation index (PI) to quantify the fluctuations in flow rate. We verified the formula for PI derived herein by varying individually both the periods and the air compliance volumes in the ACU, both theoretically and experimentally. We found that the PI depended strongly on either the time constants or the periods of the flow rates at the inlet. Additionally, the normalized differences between the experimental results and the theoretical estimations were less than 6%, which shows that the proposed formula for PI can provide an accurate quantification of the fluctuations in flow, and estimate the parametric effects. Finally, we have successfully demonstrated that our fluidic-LPF can regulate fluctuations in the flow at extremely low flow rates (~ 10 μL h(-1)) and can also control severe fluidic fluctuations (PI = 0.67) with excessively long periods (100 s) via a microfluidic viscometer. We therefore believe that the stabilization of hydrodynamic flow using a fluidic-LPF could be used easily and extensively with a range of microfluidic platforms that require constant flow rates.  相似文献   

14.
The ability to quickly measure flow parameters in microfluidic devices is critical for micro total analysis system (μTAS) applications. Macrofluidic methods to assess flow suffer from limitations that have made conventional methods unsuitable for the flow behavior profiling. Single molecule fluorescence correlation spectroscopy (FCS) has been employed in our study to characterize the fluidic vortex generating at a T-shape junction of microscale channels. Due to its high spatial and temporal resolution, the corresponding magnitudes relative to different flow rates in the main channel can be quantitatively differentiated using flow time (τF) measurements of dye molecules traversing the detection volume in buffer solution. Despite the parabolic flow in the channel upstream, a heterogeneous distribution of flow has been detected across the channel intersection. In addition, our current observations also confirmed the aspect of vortex-shaped flow in low-shear design that was developed previously for cell culture. This approach not only overcomes many technical barriers for examining hydrodynamic vortices and movements in miniature structures without physically integrating any probes, but it is also especially useful for the hydrodynamic studies in polymer-glass based micro -reactor and -mixer.  相似文献   

15.
A high-discernment microflow cytometer with microweir structure   总被引:1,自引:0,他引:1  
Fu LM  Tsai CH  Lin CH 《Electrophoresis》2008,29(9):1874-1880
Using a simple and reliable isotropic wet etching process, we fabricated a microflow cytometer in which cells/particles are concentrated in the center of the sample stream using a 2-D hydrodynamic focusing technique and an microweir structure. Having focused the cells/particles, they are detected and counted using a LIF method. The experimental and numerical results confirm the effectiveness of the hydrodynamic sheath flows in squeezing the cells/particles into a narrow stream in the horizontal X-Y plane. Furthermore, it is shown numerically that the microweir structure results in the separation of the cells/particles in the vertical X-Z plane such that they pass through the detection region in a sequential fashion and can therefore be counted with a high degree of precision. The experimental results obtained using fluorescent polystyrene beads with diameters of 5 and 10 microm, respectively, confirm the suitability of the proposed device for microfluidic applications requiring the high-precision counting of particles or cells within a sample flow.  相似文献   

16.
Long Z  Shen Z  Wu D  Qin J  Lin B 《Lab on a chip》2007,7(12):1819-1824
An integrated microfluidic device was developed for online coupling of solid-phase extraction to microchip electrophoresis (chip SPE-CE). With a nanoporous membrane sandwiched between two PDMS substrates, SPE preconcentration and electrophoretic separation can be carried out in upper and lower fluidic layers, separately and sequentially. During the SPE process, the thin membrane can act as a fluid isolator to prevent intermixing between two fluidic channels. However, when a pulse voltage is applied, the membrane becomes a gateable interconnect so that a small plug of concentrated analytes can be online injected into the lower channel for subsequent separations. This multilayer design provides a universal solution to online SPE-CE hyphenation. Both electroosmotic flow and hydrodynamic pumps have been adopted for SPE operation. SPE was performed on a 2.5 mm long microcolumn, with two weirs on both sides to retain the C(18)-coated silica beads. Rhodamine 123 and FITC-labelled ephedrine were used to test the operational performance of the hyphenation system. High separation efficiency and thousand-fold signal enhancement were achieved.  相似文献   

17.
Mao X  Waldeisen JR  Huang TJ 《Lab on a chip》2007,7(10):1260-1262
We introduce a novel fluid manipulation technique named "microfluidic drifting" to enable three-dimensional (3D) hydrodynamic focusing with a simple single-layer planar microfluidic device.  相似文献   

18.
Lee JM  Kim JE  Kang E  Lee SH  Chung BG 《Electrophoresis》2011,32(22):3133-3137
We developed an integrated microfluidic culture device to regulate embryonic stem (ES) cell fate. The integrated microfluidic culture device consists of an air control channel and a fluidic channel with 4×4 micropillar arrays. We hypothesized that the microscale posts within the micropillar arrays would enable the control of uniform cell docking and shear stress profiles. We demonstrated that ES cells cultured for 6 days in the integrated microfluidic culture device differentiated into endothelial cells. Therefore, our integrated microfluidic culture device is a potentially powerful tool for directing ES cell fate.  相似文献   

19.
Suppression of non-specific adsorption using sheath flow   总被引:1,自引:0,他引:1  
The use of a confining sheath fluid within a microfluidic channel in order prevent non-specific adsorption of analytes to the walls of microchannels is demonstrated. A sheath-flow channel fabricated using laser cutting of Mylar films is developed. Numerical simulations of convective and diffusive mass transport within the channel are presented. The device is characterized experimentally using epifluorescence microscopy. It is demonstrated that the device is capable of preventing the adsorption of Rhodamine B to the walls of the channel for a period that would allow for adsorption-free T-sensor measurements to be made within the core of the flow channel. Generalized scaling rules based on the diffusion coefficient, sheath thickness and affinity of the potential adsorbant for the surface material are discussed. The controlled adsorption of the protein bovine serum albumin (BSA) to a gold surface is also demonstrated using SPR microscopy.  相似文献   

20.
This paper introduces a method of combining open and closed microchannels in a single component in a novel way which couples the benefits of both open and closed microfluidic systems and introduces interesting on-chip microfluidic behaviour. Fluid behaviour in such a component, based on continuous pressure driven flow and surface tension, is discussed in terms of cross sectional flow behaviour, robustness, flow-pressure performance, and its application to microfluidic interfacing. The closed-open-closed microchannel possesses the versatility of upstream and downstream closed microfluidics along with open fluidic direct access. The device has the advantage of eliminating gas bubbles present upstream when these enter the open channel section. The unique behaviour of this device opens the door to applications including direct liquid sample interfacing without the need for additional and bulky sample tubing.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号