 共查询到20条相似文献,搜索用时 31 毫秒
1.
A simple and rapid flow injection (FI) method is reported for the determination of phosphate (as molybdate reactive P) in freshwaters based on luminol chemiluminescence (CL) detection. The molybdophosphoric heteropoly acid formed by phosphate and ammonium molybdate in acidic conditions generated chemiluminescence emission via the oxidation of luminol. The detection limit (3× standard deviation of blank) was 0.03 μg P l−1 (1.0 nM), with a sample throughput of 180 h−1. The calibration graph was linear over the range 0.032–3.26 μg P l−1 (r2=0.9880) with relative standard deviations (n=4) in the range 1.2–4.7%. Interfering cations (Ca(II), Mg(II), Ni(II), Zn(II), Cu(II), Co(II), Fe(II) and Fe(III)) were removed by passing the sample through an in-line iminodiacetate chelating column. Silicate interference (at 5 mg Si l−1) was effectively masked by the addition of tartaric acid and other common anions (Cl, SO42−, HCO3, NO3 and NO2) did not interfere at their maximum admissible concentrations in freshwaters. The method was applied to freshwater samples and the results (26.1±1.1–62.0±0.4 μg P l−1) were not significantly different (P=0.05) from results obtained using a segmented flow analyser method with spectrophotometric detection (24.4±4.45–84.0±16.0 μg P l−1).  相似文献   

2.
A sequential injection analysis (SIA) spectrophotometric method for the determination of trace amounts of zinc(II) with 1-(2-pyridylazo)-2-naphthol (PAN) is described. The method is based on the measurement of absorbance of the zinc(II)–PAN chelate solubilized with a non-ionic surfactant, Triton X-100, no extraction procedure is required in the proposed method, yielding a pink colored complex at pH 9.5 with absorption maximum at 553 nm. The SIA parameters that affect the signal response have been optimized in order to get the better sensitivity and minimum reagent consumption. A linear relationship between the relative peak height and concentration was obtained in the concentration range of 0.1–1.0 μg ml−1. The limit of detection (LOD, defined as 3σ) and limit of quantification (LOQ, defined as 10σ) were 0.02 and 0.06 μg ml−1, respectively. The sample throughput about 40 samples/h was obtained. The repeatability were 1.32 and 1.24% (n = 10) for 0.1 and 0.5 μg ml−1, respectively. The proposed method was successfully applied to the assay of zinc(II) in three samples of multivitamin tablets. The results were found to be in good agreement with those obtained by flame atomic absorption spectrophotometric method and with the claimed values by the manufactures. The t-test showed no significant difference at 95% confidence level.  相似文献   

3.
A HPLC method with automated column switching and UV-diode array detection is described for the simultaneous determination of Vitamin D3 and 25-hydroxyvitamin D3 (25-OH-D3) in a sample of human plasma. The system uses a BioTrap precolumn for the on-line sample cleanup. A sample of 1 ml of human plasma was treated with 2 ml of a mixture of ethanol–acetonitrile (2:1 (v/v)). Following centrifugation, the supernatant was evaporated to dryness under a stream of dry and pure nitrogen. The residue was reconstituted in 250 μL of a solution of methanol 5 mmol l−1 phosphate buffer, pH 6.5 (4:1 (v/v)), and a 200 μl aliquot of this solution was injected onto the BioTrap precolumn. After washing during 5 min with a mobile phase constituted by a solution of 6% acetonitrile in 5 mmol l−1 phosphate buffer, pH 6.5 (extraction mobile phase), the retained analytes were then transferred to the analytical column in the backflush mode. The analytical separation was then performed by reverse-phase chromatography in the gradient elution mode with the solvents A and B (Solvent A: acetonitrile–phosphate buffer 5 mmol l−1, pH 6.5; 20:80 (v/v); solvent B: methanol–acetonitrile–tetrahydrofuran, 65:20:15 (v/v)). The compounds of interest were detected at 265 nm. The method was linear in the range 3.0–32.0 ng ml−1 with a limit of quantification of 3.0 ng ml−1. Quantitative recoveries from spiked plasma samples were between 91.0 and 98.0%. In all cases, the coefficient of variation (CV) of the intra-day and inter-day-assay precision was ≤2.80%. The proposed method permitted the simultaneous determination of Vitamin D3 and 25-OH-D3 in 16 min, with an adequate precision and sensitivity. However, the overlap of the sample cleanup step with the analysis increases the sampling frequency to five samples h−1. The method was successfully applied for the determination of Vitamin D3 and 25-OH-D3 in plasma from 46 female volunteers, ranging from 50 to 94 years old. Vitamin D3 and 25-OH-D3 concentrations in plasma were found from 4.30–40.70 ng ml−1 (19.74 ± 9.48 ng ml−1) and 3.1–36.52 ng ml−1 (7.13 ± 7.80 ng ml−1), respectively. These results were in good agreement with data published by other authors.  相似文献   

4.
An atomic absorption spectrophotometric method for the determination of trace copper after adsorption of its 1-nitroso-2-naphthol-3,6-disulfonic acid chelate on Ambersorb 572 has been developed. This chelate is adsorbed on the adsorbent in the pH range 1–8. The copper chelate is eluted with 5 ml of 0.1 mol l−1 potassium cyanide and determined by flame atomic absorption spectrometry (FAAS). The selectivity of the proposed procedure was also evaluated. Results show that iron(III), zinc(II), manganese(II) and cobalt(II) at the 50 μg l−1 level and sodium(I), potassium(I), magnesium(II), calcium(II) and aluminium(III) at the 1000 μg l−1 level did not interfere. A high enrichment factor, 200, was obtained. The detection limit (3σ) of copper was 0.34 μg l−1. The precision of the method, evaluated by seven replicate analyses of solutions containing 5 μg of copper was satisfactory and the relative standard deviation was 1.7%. The adsorption of copper onto Ambersorb 572 can formally be described by a Langmuir equation with a maximum adsorption capacity of 14.3 mg g−1 and a binding constant of 0.00444 l mg−1. The accuracy of the method is confirmed by analysing tomatoes leaves (NIST 1573a) and lead base alloy (NBS 53e). The results demonstrated good agreement with the certified values. This procedure was applied to the determination of copper in waters (tap, river and thermal waters), aluminium foil and tea samples.  相似文献   

5.
Soylak M  Tuzen M  Mendil D  Turkekul I 《Talanta》2006,70(5):1129-1135
A solid phase extraction procedure based on biosorption of copper(II), lead(II), zinc(II), iron(III), nickel(II) and cobalt(II) ions on Aspergillus fumigatus immobilized Diaion HP-2MG has been investigated. The analytical conditions including amounts of A. fumigatus, eluent type, flow rates of sample and eluent solutions were examined. Good recoveries were obtained to the spiked natural waters. The influences of the concomitant ions on the retentions of the analytes were also examined. The detection limits (3sigma, N = 11) were 0.30 μg l−1 for copper, 0.32 μg l−1 for iron, 0.41 μg l−1 for zinc, 0.52 μg l−1 for lead, 0.59 μg l−1 for nickel and 0.72 μg l−1 for cobalt. The relative standard deviations of the procedure were below 7%. The validation of the presented procedure is performed by the analysis of three standard reference materials (NRCC-SLRS 4 Riverine Water, SRM 1515 Apple leaves and GBW 07605 Tea). The procedure was successfully applied for the determination of analyte ions in natural waters microwave digested samples including street dust, tomato paste, black tea, etc.  相似文献   

6.
In this work an automatic photometric procedure for the determination of chlorine in bleach samples employing N,N′-diethyl-p-phenylenediamine (DPD) as chromogenic reagent is described. The procedure was based on a falling drop system where the analyte (Cl2) was collected by a DPD solution drop (50 μL) after its delivery from the sample bulk that was previously acidified. The flow system was designed based on the multicommutation process assembling a set of three-way solenoid valves, which under microcomputer control afforded facilities to handle sample and reagent solution in order to control analyte delivering and solution drop generation. The analyte volatilization was improved by coupling online a little heating device. The detection system comprised a green LED (515 nm) and a phototransistor. Aiming to prove the usefulness of the proposed procedure a set of bleach samples was analyzed. Comparing the results with those obtained with reference method no significant difference at 95% confidence level was observed. Other profitable features such as a linear response ranging from 15 up to 100 mg L−1 Cl2 (R = 0.999); a detection limit of 4.5 mg L−1 Cl2 estimated based on the 3σ criterion; a relative standard deviation of 2.5% (n = 10) using a typical bleach sample containing 25.0 mg L−1 Cl2; a consumption of 55 μg of DPD per determination; and a analytical frequency of 20 determinations per hour were also achieved.  相似文献   

7.
Moneeb MS 《Talanta》2006,70(5):1035-1043
Polarographic chemometric methods were applied to the determination of zinc and nickel in aqueous solutions previously acidified with 0.1 M acetate buffer (pH 4.2). The studied methods are multivariate methods including classical least squares (CLS), principal component regression (PCR) and partial least squares (PLS); derivative ratio methods (first, 1D and second, 2D derivative ratio). A comparative study was considered. The studied chemometric methods do not need the presence of any reduction potential shift reagent in spite of the great overlap between the two metals polarograms. A training set consisting of 10 binary mixture solutions in the possible combinations containing 0.13–9.30 μg/ml Zn(II) and 0.20–12.25 μg/ml Ni(II) was used to develop the chemometric calibrations (CLS, PCR and PLS). A validation set containing the synthetic mixtures in the range of 0.29–9.00 μg/ml for Zn(II) and 0.30–11.60 μg/ml for Ni(II) was used to validate the multivariate calibrations. Same mixtures were used to develop the derivative ratio methods. The polarograms were recorded and their current values were measured within the potential range −920 to −1052 mV at 2 mV intervals. The mean percentage recoveries obtained using CLS, PCR and PLS were found to be 99.5 ± 1.5%, 100.0 ± 1.1% and 100.0 ± 1.0% for Zn(II) and 99.4 ± 1.3%, 99.7 ± 1.2% and 99.9 ± 1.0% for Ni(II), respectively. The mean percentage recoveries obtained using 1D at −950 mV, 1D at −1010 mV, 1D at −950 mV–1D at −1010 mV and 2D at −986 mV for Zn(II) were found to be 99.7 ± 1.2%, 99.2 ± 1.6%, 99.4 ± 1.4% and 99.4 ± 1.4%; and using 1D at −1030 mV and 2D at −1010 mV for Ni(II) were found to be 100.5 ± 1.3% and 100.4 ± 1.3%, respectively. Interferences due to the presence of Cd, Co, Pb, Fe, Mn, Ca, Mg, Cu and Al were studied. The applicability of the proposed methods was assessed through the determination of both metals in tap drinking-water. Samples were subjected if required up to a 20-fold preconcentration step by microwaving in pyrex vessels. The results were compared with those obtained using the zincon and the heptoxime colorimetric reference methods for the determination of zinc and nickel, respectively.  相似文献   

8.
Ruengsitagoon W 《Talanta》2008,74(5):1236-1241
A simple reversed flow injection colourimetric procedure for determining iron(III) was proposed. It is based on the reaction between iron(III) with chlortetracycline, resulting in an intense yellow complex with a suitable absorption at 435 nm. A 200 μl chlortetracycline reagent solution was injected into the phosphate buffer stream (flow rate 2.0 ml min−1) which was then merged with iron(III) standard or sample in dilute nitric acid stream (flow rate 1.5 ml min−1). Optimum conditions for determining iron(III) were investigated by univariate method. Under the optimum conditions, a linear calibration graph was obtained over the range 0.5–20.0 μg ml−1. The detection limit (3σ) and the quantification limit (10σ) were 0.10 and 0.82 μg ml−1, respectively. The relatives standard deviation of the proposed method calculated from 12 replicate injections of 2.0 and 10.0 μg ml−1 iron(III) were 0.43 and 0.59%, respectively. The sample throughput was 60 h−1. The proposed method has been satisfactorily applied to the determination of iron(III) in natural waters.  相似文献   

9.
Automated sequential injection (SIA) method for chemiluminescence (CL) determination of nonsteroidal anti-inflammatory drug indomethacin (I) was devised. The CL radiation was emitted in the reaction of I (dissolved in aqueous 50% v/v ethanol) with intermediate reagent tris(2,2′-bipyridyl)ruthenium(III) (Ru(bipy)33+) in the presence of acetate. The Ru(bipy)33+ was generated on-line in the SIA system by the oxidation of 0.5 mM tris(2,2′-bipyridyl)ruthenium(II) (Ru(bipy)32+) with Ce(IV) ammonium sulphate in diluted sulphuric acid. The optimum sequence, concentrations, and aspirated volumes of reactant zones were: 15 mM Ce(IV) in 50 mM sulphuric acid 41 μL, 0.5 mM Ru(bipy)32+ 30 μL, 0.4 M Na acetate 16 μL and I sample 15 μL; the flow rates were 60 μL s−1 for the aspiration into the holding coil and 100 μL s−1 for detection. Calibration curve relating the intensity of CL (peak height of the transient CL signal) to concentration of I was curvilinear (second order polynomial) for 0.1–50 μM I (r = 0.9997; n = 9) with rectilinear section in the range 0.1–10 μM I (r = 0.9995; n = 5). The limit of detection (3σ) was 0.05 μM I. Repeatability of peak heights (R.S.D., n = 10) ranged between 2.4% (0.5 μM I) and 2.0% (7 μM I). Sample throughput was 180 h−1. The method was applied to determination of 1 to 5% of I in semisolid dosage forms (gels and ointments). The results compared well with those of UV spectrophotometric method.  相似文献   

10.
A highly sensitive cathodic stripping voltammetric method for the determination of naringin is presented. It is based on the formation and accumulation of two naringin–mercury complexes at the electrode surface, followed by reduction of the surface species during a differential pulse voltammetric scan. The cathodic stripping responses at −0.25 V and −0.42 V, are evaluated with respect to various experimental conditions, such as composition and pH of the supporting electrolyte, naringin concentration, accumulation potential and preconcentration time. The new method is suitable for the determination of naringin concentrations between 0.1 mg l−1 (1.72×10−7 mol l−1) and 40 mg l−1 (6.88×10−5 mol l−1). A 3σ limit of detection of 32 μg l−1 (55 nmol l−1) can be reached. The relative standard deviation (r.s.d.) is <1.5%. Recovery experiments yielded a mean recovery of 97% (r.s.d.=4.1%). The application of the procedure to the selective determination of naringin in grapefruit juice is demonstrated.  相似文献   

11.
A novel method for the spectrophotometric determination of nitrite in water   总被引:4,自引:0,他引:4  
Aydın A  Ercan O  Taşcıoğlu S 《Talanta》2005,66(5):1181-1186
A rapid, simple, selective and sensitive method for the spectrophotometric determination of nitrite in water has been developed and optimum reaction conditions along with other analytical parameters have been evaluated. Nitrite reacts with barbituric acid in acidic solution to give the nitroso derivative, violuric acid. At analytical wavelength of 310 nm, Beer's law is obeyed over the concentration range 0.00–3.22 ppm of nitrite. The molar absorptivity is 15330 ± 259.7 (95%) with pooled standard deviation of 355.57 and R.S.D. of 2.32%. As well as the method is sensitive (2.99 × 10−3 μg NO2 cm−2) and selective, it tolerates most of the potential interferents. It has been successfully applied to nitrite determination in natural waters by use of a calibration graph with determination limit of 1.66 μg NO2 in 100 mL working solution corresponding to minimum 9.5 ppb NO2–N in water samples. Lower concentrations of nitrite (3.0 μg NO2/L sample) is precisely analyzed by using the method of dilution with sample, with R.S.D. of lower than 0.5%. The results were compared with standard N-(1-naphtyl)ethylenediamine dihydrochloride method and very good agreement between the data was observed. The method can easily be applied in the field.  相似文献   

12.
An automated method is described for the determination of zinc in human saliva by electrothermal atomic absorption spectrometry (ET AAS) after on-line dilution of samples with a significant reduction of sample consumption per analysis (<0.4 mL including the dead volume of the system). In order to fulfill this aim without changing the sample transport conduits during the experiments, a flow injection (FI) dilution system was constructed. Its principal parts are: one propulsion device (peristaltic pump, PP) for either samples, standards or washing solution all located in an autosampler tray and for the surfactant solution (Triton X-100) used as diluent, and a two-position time based solenoid injector (TBSI1) which allowed the introduction of 10 μL of either solution in the diluent stream. To avoid unnecessary waste of samples, the TBSI1 also permitted the recirculation of the solutions to their respective autosampler cups. The downstream diluted solution fills a home made sampling arm assembly. The sequential deposition of 20 μL aliquots of samples or standards on the graphite tube platform was carried out by air displacement with a similar time based solenoid injector (TBSI2). The dilution procedure and the injection of solutions into the atomizer are computer controlled and synchronized with the operation of the temperature program. Samples or standards solutions were submitted to two drying steps (at 90 and 130 °C), followed by pyrolysis and atomization at 700 and 1700 °C, respectively. The aqueous calibration was linear up to 120.0 μg L−1 for diluted standard solutions/samples and its slope was similar (p > 0.05) to the standard addition curve, indicating lack of matrix effect. The precision tested by repeated analysis of real saliva samples was less than 3% and the detection limit (3σ) was of 0.35 μg L−1. To test the accuracy of the proposed procedure, recovery tests were performed, obtaining mean recovery of added zinc of 97.8 ± 1.3%. Furthermore, Zn values estimated by the procedure developed in this work were compared with those obtained by a standard addition flame-AAS method applied to 20 randomly selected saliva samples. No significant differences (p > 0.05) were obtained between the two methods. Zinc levels in saliva samples from 44 healthy volunteers, 15 male and 29 female, with ages between 20 and 51 years (mean 30.50 ± 9.14 years) were in the range 22–98 μg L−1 (mean of 55 ± 17 μg L−1), similar to some and different from others reported in the literature. It was found that zinc values for male were statistically higher (p = 0.006) than for female.  相似文献   

13.
Pons C  Miró M  Becerra E  Estela JM  Cerdà V 《Talanta》2004,62(5):887-895
An intelligent and versatile flow system is proposed for the in-line speciation and/or concentration of metal ions at a wide range of concentrations without requiring manifold reconfiguration. On one hand, sample enrichment strategies are accomplished using packed-bed reactors, on the other hand speciation procedures are readily performed exploiting the selective complexation of the different oxidation states with the appropriate chromogenic reagents.

The potentials of the automated methodology were evaluated using the spectrophotometric monitoring of iron as a model of chemistry. Under the optimised physical and chemical variables, linear analytical curves over the ranges 0.025–0.5 or 2.0–40 mg l−1 Fe were attained. The 3σ detection limit, the repeatability at the 0.5 mg l−1 level, the enrichment factor for a sampling volume of 10 ml, and the maximum injection throughput were 8.4 ng ml−1 Fe, 2.5%, 58.6 and 22 h−1, respectively. The flowing system was applied to the speciation analysis of iron in waters, pharmaceutical formulations and agricultural products, using ICP-OES detection as an external reference method for total iron determination.

A remarkable feature of the expert system hereby presented is the ability to decide by itself if the pre-concentration and/or oxidation of the sample zone is required.  相似文献   


14.
The effect of arsenate on phosphate determination by the malachite green spectrophotometric method was investigated. The molar absorptivities of the molybdophosphate and malachite green–molybdoarsenate species at 625 nm and a final acidity of 0.38 M were calculated as 10.4±0.13×104 and 7.2±0.17×104 l mol−1 cm−1 respectively, indicating that arsenate could interfere in phosphate measurement. Arsenate concentrations as low as 23 μg l−1 caused increase in colour development in phosphate solutions. However, the extent of colour development for both anions depended on the final acid concentration of the solution. An acidified sodium sulphite solution (0.83 M NaSO3, 0.83 M H2SO4) quantitatively prevented arsenate colour development up to 300 μg l−1 As(V). It was also demonstrated that the method removed As(V) interferences in mixed As/P solutions and therefore can be used to treat natural water samples with elevated arsenate concentrations before phosphate measurement.  相似文献   

15.
The objective of this study was to investigate the retention of phosphate anions, H2PO4 and HPO42−, by nanofiltration. The first part of this study deals with the characterisation of the NF200 membrane used in permeation experiments with aqueous solutions of neutral organic and charged inorganic solutes. In the second part the effects of feed pressure, ionic strength, concentration and pH on the retention of phosphate anions were investigated. Results show that the membrane is negatively charged, its pore radius is around 0.5 nm and the retention order for the salts tested was R(Na2SO4) > R(NaCl) > R(CaCl2). The retentions of phosphate anions are in the order of 85% for H2PO4 and 96% for HPO42−. They are relatively high when compared to retentions of other anions with the same charge. The retentions of phosphate anions, particularly the monovalent species, depend on the chemical parameters (feed concentration, ionic strength, and pH) and applied pressure. The experimental data were analysed using the Speigler–Kedem model and the transport parameters, i.e., the reflection coefficient (σ) and solute permeability (Ps) have been determined.  相似文献   

16.
Meneses SR  Maniasso N  Zagatto EA 《Talanta》2005,65(5):1313-1317
A flow-injection procedure for spectrophotometric determination of sulphate in soil solutions is proposed. Samples are directly soaked from the soils under field conditions, in-line filtered through ceramic plates, and preserved with thymol. The method involves reaction with barium dimethylsulphonazo(III) (DMSA) in the presence of dimethylsulphoxide (DMSO) with further measuring the decrease in absorbance at 668 nm. A linear response is observed up to about 5 mgl −1 SO4, and detection limit (3σ criterion) is 0.1 mg l−1 SO4. Only 4.5 μg DMSA is consumed per determination. The system is rugged and baseline drift is not observed during extended operation periods. About 60 samples are injected per hour, and the results are precise (r.s.d. <2%) and in agreement with ion chromatography.  相似文献   

17.
Silva AR  Nogueira JM 《Talanta》2008,74(5):1498-1504
Stir bar sorptive extraction and liquid desorption followed by high performance liquid chromatography with diode array detection (SBSE-LD-LC-DAD) is proposed for the determination of triclosan in personal care products, biological and environmental matrices, which is included in the priority lists, set by several international regulatory organizations. Instrumental conditions and experimental parameters that affecting SBSE-LD efficiency are fully discussed. Throughout systematic assays on 25 mL water samples spiked at the 10.0 μg L−1 level, it had been established that stir bars coated with 126 μL of polydimethylsiloxane, an equilibrium time of 1 h (1000 rpm) and acetonitrile under sonification (60 min) as back-extraction solvent, allowed the best analytical performance to determine triclosan in water matrices. From the data obtained, good recovery and remarkable repeatability were attained, providing experimental average yields (78.5 ± 2.2%), although slightly lower than the theoretical equilibrium (99.7%) described by the octanol–water partition coefficients (KPDMS/W < KO/W). The analytical performance proved suitable precision (<3.6%), convenient detection limits (0.1 μg L−1) and excellent linear dynamic range (r2 > 0.9992) from 0.4 to 108.0 μg L−1. The application of the present method to determine triclosan in real matrices such as commercial toothpaste, saliva and urban wastewater samples, allowed appropriate selectivity, high sensitivity and accuracy using the standard addition methodology. The proposed method showed to be feasible and sensitive with a low-sample volume requirement to monitor triclosan in personal care products, biological and environmental matrices at the trace level, in compliance with international regulatory directives.  相似文献   

18.
For the first time a new, sensitive, and simple bead injection spectroscopy–flow injection analysis (BIS–FIA) system with spectrofluorimetric detection is described for the sequential determination of two metals. The sensor is based on the alternate use of two carriers and a commercially available flow cell (Hellma 176-QS). The flow cell is filled by injecting in the flow system 500 μl of a homogeneous bead suspension of an appropriate solid support (Sephadex QAE A-25) previously loaded with the fluorogenic reagent morin (2′,3,4′,5,7-pentahydroxyflavone). A sequential reaction of Al(III) and Be(II) with morin (immobilized on beads) to form their fluorescent complexes is performed on the bead sensing support and their respective fluorescence emission monitored, after doing two successive injections from the mixture solution. Firstly, Al(III) could be determined in the sample using 0.5 M NaCl/HCl, pH 6 as carrier. Then, the carrier solution was changed (0.3 M NaCl/NaOH, pH 12) making possible the elution of Al(III) and the restoration of the baseline, then allowing the reaction of Be(II). At the end of the analysis, beads are automatically discarded from the flow cell, by reversing the flow, and transported out of the system. The analytical signals are measured at an excitation wavelength of 440 nm and an emission wavelength of 520 nm. Using a sample volume of 600 μl, the analytical signal showed a very good linearity in the range 0.1–8 ng ml−1 and 0.1–1 μg ml−1 with detection limits of 0.024 ng ml−1 and 0.010 μg ml−1 for Be(II) and Al(III), respectively. R.S.D.s (%) lower than 5% were obtained for both analytes and the selectivity was improved using EDTA as masking reagent. The sensor was satisfactorily applied to the determination of these metals in waters and simulated alloy samples.  相似文献   

19.
Li YS  Ju X  Gao XF  Zhao YY  Wu YF 《Analytica chimica acta》2008,610(2):249-256
A new method for the determination of lactic acid based on the immobilization enzyme fluorescence capillary analysis (IE-FCA) was proposed. Lactic dehydrogenase (LDH) was immobilized on inner surface of a capillary with glutaraldehyde, and an immobilized enzyme lactate capillary bioreactor (IE-LCBR) was formed for the determination of lactic acid. After nicotinamide adenine dinucleotide (NAD+) is mixed with lactic acid solution, it was sucked into the IE-LCBR and was detected at λex 353 nm/λem 466 nm. Optimized conditions are as follows: the temperature is 38 °C; the reaction time is 15 min; the concentrations of Tris buffer (pH 8.8) and NAD+ are 0.1 mol L−1 and 4 mmol L−1, respectively; the concentration of LDH used for immobilization is 15 kU L−1. The concentration of lactic acid is directly proportional to the fluorescence intensity measured from 0.50 to 2.0 mmol L−1; and the analytical recovery of added lactic acid was 99–105%. The minimum detection limit of the method is 0.40 mmol L−1 and sensitivity of the IE-CBR is 4.6 F mmol−1 L−1 lactate. Its relative standard deviation (R.S.D.) is ≤2.0%. This IE-FCA method was employed for determination of lactate in milk drink.  相似文献   

20.
Recent developments in the field of microbiology and research on the origin of life have suggested a possible significant role for reduced, inorganic forms of phosphorus (P) such as phosphite [HPO32−, P(+III)] and hypophosphite [H2PO2, P(+I)] in the biogeochemical cycling of P. New, robust methods are required for the detection of reduced P compounds in order to confirm the importance of these species in the overall cycling of P in the environment. To this end, we have developed new batch and flow injection (FI) methods for the determination of P(+III) in aqueous solutions. The batch method is based on the reaction of P(+III) with a mixed-iodide solution containing tri-iodide (I3) and penta-iodide (I5). The oxidation of P(+III) consumes free I3 and I5 in solution. The remaining I3 and I5 subunits are then allowed to react with the amylose content in starch to form a blue complex, which has a λmax of 580 nm. The measurement of this blue complex is directly correlated with the concentration of P(+III). The on-line FI method employs the same reaction between P(+III) and mixed-iodide producing phosphate [P(+V)] that is determined spectrophotometrically by the molybdenum blue method employing ascorbic acid at a λmax of 710 nm. The linear range for both the batch and FI determination of P(+III) was 1.0–50 μM with detection limits of 0.70 and 0.36 μM, respectively. Interference studies for the batch method show that arsenite [As(+III)] and sulfite [S(+IV)] can also be determined by this technique; however, these interferences can be circumvented by oxidizing As(+III) and S(+IV) using KMnO4 which is an ineffective oxidant for P(+III). Both methods were applied to P(+III) determinations in ultra-pure water and simulated creek water. Results and analytical figures of merit are reported and future work is considered.  相似文献   