首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This work compared the performance of four navigator gating algorithms [accept/reject (A/R), diminishing variance algorithm (DVA), phase ordering with automatic window selection (PAWS) and retrospective gating (RETRO)] in suppressing respiratory motion artifacts in free-breathing 3D balanced steady-state free precession coronary MRA. In 10 volunteers, the right coronary artery (RCA) or the left anterior descending artery (LAD) was imaged (both if time permitted) at 1.5 T with the four gating techniques in random order. Vessel signal, vessel contrast and motion suppression were scored by the consensus of two blinded readers. In 15 imaged vessels (nine RCA and six LAD), PAWS provided significantly better image quality than A/R (P<.05), DVA (P=.02) and RETRO (P=.002). While the quality difference between A/R and DVA was not statistically significant, both algorithms yielded significantly better image quality than RETRO. PAWS and DVA were the most efficient algorithms, providing an approximately 20% and 40% relative increase in average navigator efficiency compared to A/R and RETRO, respectively.  相似文献   

2.

Purpose

To prospectively evaluate diffusion-weighted (DW) magnetic resonance (MR) imaging for differentiation of postobstructive consolidation from centrally located lung carcinomas by using apparent diffusion coefficients (ADCs).

Materials and Methods

An institutional review board approved this study; informed consent was obtained from patients. Forty-nine consecutive patients (3 women, 46 men; mean age, 63.6 years; age range, 42–85 years) with lung carcinoma underwent DW MR imaging. Forty patients had central and nine patients had peripheral lung carcinomas. ADC of each lung carcinoma was calculated from DW MR images obtained with two different b values (0, 1000 s/mm2).In the final study group including 27 patients with central lung carcinoma accompanying distal lung consolidation (mean age, 67.2 years; 3 women, 24 men), ADCs of lung carcinomas were statistically compared among cytologic/histologic types and accompanying postobstructive consolidations. Unpaired t test was used for measurable variables with normal distribution, and Kruskal–Wallis variance analysis and Mann–Whitney U tests were used for the measurable variables without normal distribution.

Results

There was no significant difference between mean ADC values of all types of carcinomas (P=.302) and also between mean ADC values of central (1.91 ± 0.7×10−3 mm2/s) and peripheral carcinomas (1.58 ± 0. 6×10−3 mm2/s) (P=.224). The mean ADC value for the masses of central lung carcinoma with postobstructive consolidations was 1.83 ± 0.75×10−3 mm2/s, and for consolidation was 2.50 ± 0.76×10−3 mm2/s. ADC of central carcinoma masses was significantly lower than that of postobstructive consolidations (P=.003).

Conclusions

ADC values of central lung carcinoma masses appear to be lower than accompanying postobstructive consolidations. ADC values could be considered useful as a differentiating parameter among central lung carcinomas and accompanying postobstructive consolidations.  相似文献   

3.

Purpose

The objective of this study was to evaluate diffusion anisotropy of the breast parenchyma and assess the range and repeatability of diffusion tensor imaging (DTI) parameters in normal breast tissue.

Materials and Methods

The study was approved by our institutional review board and included 12 healthy females (median age, 36 years). Diffusion tensor imaging was performed at 1.5 T using a diffusion-weighted echo planar imaging sequence. Diffusion tensor imaging parameters including tensor eigenvalues (λ1, λ2, λ3), fractional anisotropy (FA) and apparent diffusion coefficient (ADC) were measured for anterior, central and posterior breast regions.

Results

Mean normal breast DTI measures were λ1=2.51×10−3 mm2/s, λ2=1.89×10−3 mm2/s, λ3=1.39×10−3 mm2/s, ADC=1.95±0.24×10−3 mm2/s and FA=0.29±0.05 for b=600 s/mm2. Significant regional differences were observed for both FA and ADC (P<.05), with higher ADC in the central breast and higher FA in the posterior breast. Comparison of DTI values calculated using b=0, 600 s/mm2 vs. b=0, 1000 s/mm2, showed significant differences in ADC (P<.001), but not FA. Repeatability assessment produced within-subject coefficient of variations of 4.5% for ADC and 11.4% for FA measures.

Conclusion

This study demonstrates anisotropy of water diffusion in normal breast tissue and establishes a normative range of breast FA values. Attention to the influence of breast region and b value on breast DTI measurements may be important for clinical interpretation and standardization of techniques.  相似文献   

4.

Purpose

The purpose of this study was to investigate the combined effect of hypertension and type 2 diabetes mellitus (DM2) on aortic stiffness and endothelial dysfunction by using an integrated MRI approach.

Materials and Methods

A total of 31 non-hypertensive DM2 patients and 31 hypertensive DM2 patients underwent 3.0-T MRI. Aortic distensibility (AD), pulse wave velocity (PWV) and brachial artery flow-mediated dilation (FMD) were assessed. Student's t-test, Mann–Whitney U test, chi-squared test, Pearson correlation analysis, and univariable and multiple linear regression analyses were used for statistical analyses.

Results

The hypertensive patients showed lower AD at multiple levels (ascending aorta [AA]: 2.07 ± 0.98 × 10− 3 mm Hg− 1 vs. 3.21 ± 1.70 × 10− 3 mm Hg− 1, p < 0.01; proximal thoracic descending aorta [PDA]: 2.58 ± 0.72 × 10− 3 mm Hg− 1 vs. 3.58 ± 1.47 × 10− 3 mm Hg− 1, p < 0.01; distal descending aorta [DDA]: 3.11 ± 1.84 × 10− 3 mm Hg− 1 vs. 4.27 ± 1.75 × 10− 3 mm Hg− 1, p < 0.01); faster PWV (7.46 ± 2.28 m/s vs. 5.82 ± 1.12 m/s, p < 0.05) and lower FMD (12.67% ± 6.49% vs. 20.66% ± 9.7%; p < 0.01). Systolic blood pressure was an independent predictor of PWV, AA-AD, DDA-AD and FMD. FMD was statistically significantly associated with PWV (r = − 0.37, p < 0.01) and AD (p < 0.01).

Conclusions

Hypertension has a contributive effect on aortic stiffness and endothelial dysfunction in DM2 patients.  相似文献   

5.

Objectives

The purpose of this study was to (a) investigate the image quality of phase-sensitive dual-inversion recovery (PS-DIR) coronary wall imaging in healthy subjects and in subjects with known coronary artery disease (CAD) and to (b) investigate the utilization of PS-DIR at 3 T in the assessment of coronary artery thickening in subjects with asymptomatic but variable degrees of CAD.

Materials and Methods

A total of 37 subjects participated in this institutional review board-approved and HIPAA-compliant study. These included 21 subjects with known CAD as identified on multidetector computed tomography angiography (MDCT). Sixteen healthy subjects without known history of CAD were included. All subjects were scanned using free-breathing PS-DIR magnetic resonance imaging (MRI) for the assessment of coronary wall thickness at 3 T. Lumen–tissue contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR) and quantitative vessel parameters including lumen area and wall thickness were measured. Statistical analyses were performed.

Results

PS-DIR was successfully completed in 76% of patients and in 88% of the healthy subjects. Phase-sensitive signed-magnitude reconstruction, compared to modulus-magnitude images, significantly improved lumen–tissue CNR in healthy subjects (26.73 ± 11.95 vs. 14.65 ± 9.57, P < .001) and in patients (21.45 ± 7.61 vs. 16.65 ± 5.85, P < .001). There was no difference in image CNR and SNR between groups. In arterial segments free of plaques, coronary wall was thicker in patients in comparison to healthy subjects (1.74 ± 0.27 mm vs. 1.17 ± 0.14 mm, P < .001), without a change in lumen area (4.51 ± 2.42 mm2 vs. 5.71 ± 3.11 mm2, P = .25).

Conclusions

This is the first study to demonstrate the feasibility of successfully obtaining vessel wall images at 3 T using PS-DIR in asymptomatic patients with known variable degrees of CAD as detected by MDCT. This was achieved with a fixed subject-invariant planning of blood signal nulling. With that limitation alleviated, PS-DIR coronary wall MRI is capable of detecting arterial thickening and positive arterial remodeling at 3 T in asymptomatic CAD.  相似文献   

6.

Purpose

To predict malignancy of mediastinal lymphadenopathy with diffusion-weighted imaging.

Material and methods

A prospective study was conducted on 35 patients with mediastinal lymphadenopathy (28 malignant and seven benign nodes). They underwent echoplanar diffusion-weighted magnetic resonance imaging of the mediastinum with b-factors of 0, 300 and 600 s/mm2. The apparent diffusion coefficient (ADC) values of the mediastinal lymph nodes were calculated. The ADC values were correlated with the biopsy results and statistical analysis was done. A value of P<.05 was considered significant.

Results

The mean ADC value of malignant mediastinal lymphadenopathy (1.06±0.3×10−3 mm2/s) was significantly lower (P=.001) than that of benign lymphadenopathy (2.39±0.7×10−3 mm2/s). There was an insignificant difference in the ADC values between metastatic and lymphomatous mediastinal lymph nodes (P=.32) as well as within benign nodes (P=.07). When an ADC value of 1.85×10−3 mm2/s was used as a threshold value for differentiating malignant mediastinal nodes from benign nodes, the best results were obtained with an accuracy of 83.9%, a sensitivity of 96.4%, a specificity of 71.4%, a negative predictive value of 95.2% and a positive predictive value of 77.1%. The area under the curve was 0.98.

Conclusion

Diffusion weighted magnetic resonance imaging is a promising noninvasive imaging modality that can be used for characterization of mediastinal lymphadenopathy and differentiation of malignant from benign mediastinal lymph nodes.  相似文献   

7.
To shorten scanning time and increase the feasibility of experimental results, we performed right coronary artery magnetic resonance angiography (CMRA) at 3.0 T using dual acceptance window weighting function in 25 normal subjects. We examined these subjects using conventional navigator with fixed gating window and 6 dual acceptance window weighted gating (DAWG) sequences with different central weighted ratio (CWR). Compared with the conventional navigator sequence, DAWG sequences with CWRs of 20% and 25% increased the scanning efficiency by 30% and 26% respectively (P<.05), while maintaining good image quality; further the corresponding scanning time decreased from 2.12–1.64 and 1.69 min, respectively (P<.05). However, CWRs less than 15% caused image degradation to some extent. The coronary artery lengths and diameters did not show statistically significant differences between the two techniques (P>.05). Briefly, to avoid the problems caused by low navigator efficiency and to maintain comparable image quality, the weighted gating parameters of 3 mm width central acceptance window and 15 mm width outer acceptance window with CWR between 20% and 25% are recommended for right CMRA at 3 T.  相似文献   

8.

Object

To assess the feasibility of measuring diffusion and perfusion fraction in vertebral bone marrow using the intravoxel incoherent motion (IVIM) approach and to compare two fitting methods, i.e., the non-negative least squares (NNLS) algorithm and the more commonly used Levenberg–Marquardt (LM) non-linear least squares algorithm, for the analysis of IVIM data.

Materials and Methods

MRI experiments were performed on fifteen healthy volunteers, with a diffusion-weighted echo-planar imaging (EPI) sequence at five different b-values (0, 50, 100, 200, 600 s/mm2), in combination with an STIR module to suppress the lipid signal. Diffusion signal decays in the first lumbar vertebra (L1) were fitted to a bi-exponential function using the LM algorithm and further analyzed with the NNLS algorithm to calculate the values of the apparent diffusion coefficient (ADC), pseudo-diffusion coefficient (D*) and perfusion fraction.

Results

The NNLS analysis revealed two diffusion components only in seven out of fifteen volunteers, with ADC = 0.60 ± 0.09 (10− 3 mm2/s), D* = 28 ± 9 (10− 3 mm2/s) and perfusion fraction = 14% ± 6%. The values obtained by the LM bi-exponential fit were: ADC = 0.45 ± 0.27 (10− 3 mm2/s), D* = 63 ± 145 (10− 3 mm2/s) and perfusion fraction = 27% ± 17%. Furthermore, the LM algorithm yielded values of perfusion fraction in cases where the decay was not bi-exponential, as assessed by NNLS analysis.

Conclusion

The IVIM approach allows for measuring diffusion and perfusion fraction in vertebral bone marrow; its reliability can be improved by using the NNLS, which identifies the diffusion decays that display a bi-exponential behavior.  相似文献   

9.

Purpose

To evaluate the semiquantitative DCE and quantitative DWI parameters in endometrial cancer, in order to assess the presence of neoplastic tissue and normal myometrium and to ascertain a potential relationship with tumor grade.

Methods and materials

A total of 57 patients with biopsy-proven endometrial adenocarcinoma who underwent MR imaging examination for staging purposes were retrospectively evaluated. Imaging protocol included multiplanar T1- and T2-weighted TSE, DCE T1-weighted (THRIVE; 0, 30, 90 and 120 seconds after intravenous injection of gadolinium) and DWIBS sequences (b values = 0 and 1000 mm2/s). Color perfusion and ADC maps were automatically generated on dedicated software. Relative enhancement (RE, %), maximum enhancement (ME, %), maximum relative enhancement (MRE, %), time to peak (TTP, s) and mean apparent diffusion coefficient (ADC) were calculated by manually drawing a region of interest (ROI) both on the neoplastic tissue and the normal myometrium. Histopathology was used as reference standard.

Results

Histopathological analysis confirmed the presence of endometrial carcinoma in all patients. Neoplastic tissue demonstrated significantly lower (P < 0.001) values of RE (%) 63.92 ± 35.68; ME (%) 864.91 ± 429.54 and MRE (%) 75.97 ± 38.26 as compared to normal myometrium (RE (%) 151.43 ± 55.99; ME (%) 1800.73 ± 721.32; MRE (%) 158.28 ± 54.05). TTP was significantly higher (P < 0.05) in tumor lesion (385.51 ± 1630.27 vs 195.44 ± 78.69). Mean ADC value of neoplastic tissue (775.09 ± ?220.73 × 10− 3 mm2/s) was significantly lower (P < 0.05) than in myometrium (1602.37 ± 378.54 × 10− 3 mm2/s). The analysis of perfusion and diffusion parameters classified according to tumor grades, showed a statistically significant difference only for RE (P = 0.043) and ME (P = 0.007).

Conclusions

Perfusion parameters and mean ADC differ significantly between endometrial cancer and normal myometrium, potentially reflecting the different microscopical features of cellularity and vascularity; however a significant relationship with tumor grade was not found in our series.  相似文献   

10.

Objective

To evaluate the correlation between findings from diffusion weighted imaging (DWI) and microvascular density (MVD) measurements in VX2 liver tumors after transarterial embolization ablation (TEA).

Materials and Methods

Eighteen New Zealand white rabbits were used in this study. VX2 tumor cells were implanted in livers by percutaneous puncture under computed tomography (CT) guidance. Two weeks later, all rabbits underwent conventional magnetic resonance imaging (MRI) (T1 and T2 imaging), DWI, (b = 100, 600, and 1000 s/mm2) and TEA. MRI was performed again1 week after TEA. Liver tissue was then harvested and processed for hematoxylin and eosin (H&E) staining and immunohistochemical staining for CD31to determine MVD.

Results

VX2 liver tumors were successfully established in all 18 rabbits. Optimal contrast was achieved with a b value of 600 s/mm2.The maximum pre-operative apparent diffusion coefficient (ADC)difference value was 0.28 × 10− 3 ± 0.10 × 10− 3 mm2/s, and was significantly different (P < 0.001) from the maximum postoperative ADCdifference value of 0.47 × 10− 3 ± 0.10 × 10− 3 mm2/s. However, the mean ADC value for the entire tumor was not significantly correlated with MVD (r = 0.221, P = 0.379), nor was the ADC value for the regions of viable tumor (r = − 0.044, P = 0.862). However, the maximum postoperative ADCdifference value was positively correlated with MVD(r = 0.606, F = 12.247, P = 0.003).

Conclusion

DWI is effective to evaluate the therapeutic efficacy of TEA. The maximum ADCdifference offers a promising new method to noninvasively assess tumor angiogenesis.  相似文献   

11.

Purpose

This retrospective study was designed to evaluate the apparent diffusion coefficient (ADC) of line scan diffusion images (LSDI) in normal prostate and prostate cancer. Single-shot echo planner images (SS-EPI) were used for comparison.

Materials and Methods

Twenty prostate tumors were examined by conventional MRI in 14 patients prior to radical prostatectomy. All patients were examined with a 1.5-T MR imager (Signa CV/i ver. 9.1 GE Medical System Milwaukee, WI, USA). Diffusion-weighted MR imaging (DWI) using LSDI was performed with a pelvic phased-array coil, with b values of 5 and 800 s/mm2. DWI using SS-EPI was performed with a body coil, with b values of 0 and 800 s/mm2. The ADCs of each sequence for 14 normal prostate and 20 prostate cancers were histopathologically assessed. Signal-to-noise ratio (SNR) on DWI was estimated and compared for each sequence.

Results

The mean ADCs (±S.D.) of normal peripheral zones (PZ), transition zones (TZ) and cancer (in 10−3 mm2/s) that used LSDI were 1.42±0.12, 1.23±0.10 and 0.79±0.19, respectively. Those that used SS-EPI were 1.76±0.26, 1.38±0.20 and 1.05±0.27, respectively. Using unpaired t test (P<.05), we found a significant difference in each sequence between normal tissue (both PZ and TZ) and the cancer. Paired t test (P<.05) also registered a significant difference between LSDI and SS-EPI. Mean SNR for DWI using LSDI was 16.49±5.03, while the DWI using SS-EPI was 18.85±9.26. The difference between the SNR of each sequence was not statistically significant by paired t test.

Conclusion

We found that ADCs using LSDI and SS-EPI showed similar tendencies in the same patients. However, in all regions, LSDI ADCs had smaller standard deviations than SS-EPI ADCs.  相似文献   

12.
Recently, 3-T magnetic resonance imaging (MRI) has been introduced for bone imaging. Through higher signal-to-noise ratios, as compared to 1.5-T MRI, it promises to be a more powerful tool for the assessment of cortical and trabecular bone measures. The goal of our study was to compare MRI-derived cortical and trabecular bone measures to quantitative computed tomography (QCT)-derived bone mineral density (BMD). Using 3-T MRI in 51 postmenopausal women, apparent (app.) measures of bone volume/total volume, trabecular number (Tb.N), trabecular thickness (Tb.Th) and trabecular separation were derived at the distal radius, distal tibia and calcaneus. Cortical thickness (Ct.Th) was calculated at the distal radius and distal tibia. These measures were compared to QCT-derived BMD of the spine, hip and radius. Significant correlations (?P<.05; ??P<.001; ???P<.0001) were found between spine BMD- and MRI-derived Ct.Th (rradius=.55, ?P<.05; rtibia=.67, ???P<.0001) and app. Tb.N (rradius=.33, ?P<.05; rtibia=.35, ?P<.05) at the radius and tibia. Furthermore, within the first 10 mm at the radius, an inverse correlation for Ct.Th and app. BV/TV (r6mm=−.56, P<.001; r10mm=−.36, P<.05) and app. Tb.Th (r6mm=−.54, P<.001; r10mm=−.41, P<.05) was found.  相似文献   

13.

Purpose

To evaluate the usefulness of diffusion-weighted magnetic resonance imaging (DW-MRI) in the differentiation of cystic pancreatic lesions.

Materials and Methods

Institutional review board approval was obtained, and written informed consent was taken from all enrolled subjects. Fifty-four patients with cystic pancreatic lesions of at least 1 cm in diameter (range:10–96 mm) at ultrasonography and/or computed tomography and 10 normal subjects underwent MRI at 1.5 T. These subjects included thirty-four patients with intraductal papillary mucinous tumors (IPMTs), 10 with pseudocysts, 5 with serous cystoadenoma and 5 with mucinous cystoadenoma. The MR protocol included axial T1w and T2w sequences and coronal MR cholangiopancreatography images. DW-MRI was performed using a breath-hold single-shot echo-planar sequence with a b gradient factor value of 500 s/mm2 in the three orthogonal axes. Apparent diffusion coefficient (ADC) was calculated for cerebrospinal fluid, normal pancreatic parenchyma, and for each focal pancreatic lesion. Imaging results were correlated with endoscopic retrograde cholangiopancreatography, endoscopic ultrasound-guided fine needle aspiration, surgery and/or imaging follow-up.

Results

Mean ADC value was 4.1×10−3 mm2/s for cerebrospinal fluid, 1.73×10−3 mm2/s for normal pancreatic parenchyma, 4.09×10−3 mm2/s for IPMT, 3.89×10−3 mm2/s for mucinous cystoadenoma, 3.65×10−3 mm2/s for serous cystoadenoma and 2.83×10−3 mm2/s for pseudocyst. Mean ADC values of each of the different types of pancreatic lesions were statistically different (P<.05).

Conclusion

DW-MRI may be helpful in the differential diagnosis of cystic pancreatic lesions.  相似文献   

14.

Purpose

To evaluate which mathematical model (monoexponential, biexponential, statistical, kurtosis) fits best to the diffusion-weighted signal in prostate magnetic resonance imaging (MRI).

Materials and Methods

24 prostate 3-T MRI examinations of young volunteers (YV, n= 8), patients with biopsy proven prostate cancer (PC, n= 8) and an aged matched control group (AC, n= 8) were included. Diffusion-weighted imaging was performed using 11 b-values ranging from 0 to 800 s/mm2.

Results

Monoexponential apparent diffusion coefficient (ADC) values were significantly (P<.001) lower in the peripheral (PZ) zone (1.18±0.16 mm2/s) and the central (CZ) zone (0.73±0.13 mm2/s) of YV compared to AC (PZ 1.92±0.17 mm2/s; CZ 1.35±0.21 mm2/s). In PC ADCmono values (0.61±0.06 mm2/s) were significantly (P<.001) lower than in the peripheral of central zone of AC. Using the statistical analysis (Akaike information criteria) in YV most pixels were best described by the biexponential model (82%), the statistical model, respectively kurtosis (93%) each compared to the monoexponential model. In PC the majority of pixels was best described by the monoexponential model (57%) compared to the biexponential model.

Conclusion

Although a more complex model might provide a better fitting when multiple b-values are used, the monoexponential analyses for ADC calculation in prostate MRI is sufficient to discriminate prostate cancer from normal tissue using b-values ranging from 0 to 800 s/mm2.  相似文献   

15.

Purpose

To retrospectively identify apparent diffusion coefficient (ADC) values of pediatric abdominal mass lesions, to determine whether measured ADC of the lesions and signal intensity on diffusion-weighted (DW) images allow discrimination between benign and malignant mass lesions.

Materials and Methods

Approval for this retrospective study was obtained from the institutional review board. Children with abdominal mass lesions, who were examined by DW magnetic resonance imaging (MRI) were included in this study. DW MR images were obtained in the axial plane by using a non breath-hold single-shot spin-echo sequence on a 1.5-T MR scanner. ADCs were calculated for each lesion. ADC values were compared with Mann–Whitney U test. Receiver operating characteristic curve analysis was performed to determine cut-off values for ADC. The results of visual assessment on b800 images and ADC map images were compared with chi-square test.

Results

Thirty-one abdominal mass lesions (16 benign, 15 malignant) in 26 patients (15 girls, 11 boys, ranging from 2 days to 17 years with 6.9 years mean) underwent MRI. Benign lesions had significantly higher ADC values than malignant ones (P<.001). The mean ADCs of malignant lesions were 0.84±1.7×10−3 mm2/s, while the mean ADCs of the benign ones were 2.28±1.00×10−3 mm2/s. With respect to cutoff values of ADC: 1.11×10−3 mm2/s, sensitivity and negative predictive values were 100%, specificity was 78.6% and positive predictive value was 83.3%. For b800 and ADC map images, there were statistically significant differences on visual assessment. All malignant lesions had variable degrees of high signal intensity whereas eight of the 16 benign ones had low signal intensities on b800 images (P<.001). On ADC map images, all malignant lesions were hypointense and most of the benign ones (n=11, 68.7%) were hyperintense (P<.001).

Conclusion

DW imaging can be used for reliable discrimination of benign and malignant pediatric abdominal mass lesions based on considerable differences in the ADC values and signal intensity changes.  相似文献   

16.
17.
Previous studies investigated the effect of successful coronary artery bypass grafting (CABG) upon left ventricular function. The relationship between myocardial metabolism and heart function after CABG remains unclear. We investigated the relationship between high-energy phosphate (HEP) and cardiac function following CABG using cine magnetic resonance imaging (cine-MRI) and phosphorus-31 magnetic resonance spectroscopy (31P-MRS). A retrospective study was approved by the institutional review board. MRI and 31P-MRS examinations were reviewed of 37 patients with multivessel disease who underwent CABG. 13 of these patients selected for the retrospective analysis had ≥70% stenosis in the proximal left anterior descending artery (LAD) and left ventricular ejection fraction (LVEF) <40%. LVEF was evaluated using cine-MRI. HEP such as phosphocreatine (PCr) and adenosine triphosphate (β-ATP) was measured using 31P-MRS to calculate PCr/β-ATP ratio. Cine-MRI and 31P-MRS measurements were performed before and after CABG, respectively. Ten normal healthy volunteers served as controls. 31P-MRS in 13 patients showed that post-CABG PCr/β-ATP ratio was significantly higher than that of pre-CABG (pre-CABG vs. post-CABG, 1.43±0.24 vs. 1.71±0.29, P<.05), but both ratios were significantly lower than control group (2.13±0.21, P<.05). With the change of the ratio, the left ventricle function was significantly improved (LVEF: pre-CABG vs. post-CABG: 35.7±12.9 vs. 45.6±17.2, P<.05).  相似文献   

18.
EPR study of the Cr3+ ion doped l-histidine hydrochloride monohydrate single crystal is done at room temperature. Two magnetically inequivalent interstitial sites are observed. The hyperfine structure for Cr53 isotope is also obtained. The zero field and spin Hamiltonian parameters are evaluated from the resonance lines obtained at different angular rotations and the parameters are: D=(300±2)×10−4 cm−1, E=(96±2)×10−4 cm−1, gx=1.9108±0.0002, gy=1.9791±0.0002, gz=2.0389±0.0002, Ax=(252±2)×10−4 cm−1, Ay=(254±2)×10−4 cm−1, Az=(304±2)×10−4 cm−1 for site I and D=(300±2)×10−4 cm−1, E=(96±2)×10−4 cm−1, gx=1.8543±0.0002, gy=1.9897±0.0002, gz=2.0793±0.0002, Ax=(251±2)×10−4 cm−1, Ay=(257±2)×10−4 cm−1, Az=(309±2)×10−4 cm−1 for site II, respectively. The optical absorption studies of single crystals are also carried out at room temperature in the wavelength range 195-925 nm. Using EPR and optical data, different bonding parameters are calculated and the nature of bonding in the crystal is discussed. The values of Racah parameters (B and C), crystal field parameter (Dq) and nephelauxetic parameters (h and k) are: B=636, C=3123, Dq=2039 cm−1, h=1.46 and k=0.21, respectively.  相似文献   

19.
From the electroreflectance spectra measured under hydrostatic pressure to 7 kbar we have determined the pressure coefficients for germanium (dE1/dP = 7.8 ± 0.4−6eV/bar, dP = 1.4 ± 0.8 10−6eV/bar), for Si (dEo/dP = 1 ± 1 10−6eV/bar, dE1dP = 6.2 ± 0.4 10−6eV/bar) and for GeSi alloys in the entire composition region. For the composition 80–100% of Si which is widely discussed in the literature, we could distinguish two maxima with substantially different pressure coefficients. The absolute experimental values of dE/dP agree rather well with theoretical values which, together with composition shift of electroreflectance peaks, enable us to connect the peak E1 predominantly with λ and L and Eo with Г and Δ transitions in the entire composition region.  相似文献   

20.
The aim of the study was to evaluate the relationship between the presence of right ventricular abnormalities detected by cardiac magnetic resonance (CMR) and QRS dispersion, the strongest independent predictor of sudden death in ARVC. A consecutive series of 40 patients from a single institution were recruited with a clinical diagnosis of ARVC based on the diagnostic criteria. All patients underwent systematic clinical evaluation, including history and examination, electrocardiography, 24-h Holter monitor, chest radiography, echocardiography and CMR examination and were divided into two groups according to the QRS dispersion: group I, QRS dispersion ≥ 40 ms; group II, QRS dispersion < 40 ms. The relationship between the characteristic parameters of CMR image and QRS dispersion were analyzed in two groups. There were significant differences in QRS dispersion (57±14 ms vs. 26±11 ms), right ventricular end-diastolic diameter (57±10 mm vs. 48±11 mm, P=.012), right ventricular end-systolic diameter (52±10 mm vs. 44±11 mm, P=.010), right ventricular end-diastolic volume (260±105 ml vs. 180±66 ml, P=.006), right ventricular end-systolic volume (222±98 ml vs. 148±61 ml, P=.006) and myocardial fibrosis detection rate (74% vs. 38%, P=.024) between two groups. For all patients with ARVC, QRS dispersion and right ventricular end-diastolic volume (r= 0.66, P<.001), right ventricular end-systolic volume (r= 0.67, P<.001), right ventricular outflow tract area (r= 0.68, P<.001) showed a moderate positive correlation. Right ventricular outflow tract area, right ventricular end-diastolic volume and end-systolic volume detected by CMR in patients with ARVC were positively correlated to the extent of QRS dispersion (≥ 40 ms), the strongest independent predictor of sudden cardiac death.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏