A carbon nanotubes‐based amperometric cholesterol biosensor has been fabricated through layer‐by‐layer (LBL) deposition of a cationic polyelectrolyte (PDDA, poly(diallyldimethylammonium chloride)) and cholesterol oxidase (ChOx) on multi‐walled carbon nanotubes (MWNTs)‐modified gold electrode, followed by electrochemical generation of a nonconducting poly(o‐phenylenediamine) (PPD) film as the protective coating. Electrochemical impedance measurements have shown that PDDA/ChOx multilayer film could be formed uniformly on MWNTs‐modified gold electrode. Due to the strong electrocatalytic properties of MWNTs toward H2O2 and the low permeability of PPD film for electroacitve species, such as ascorbic acid, uric acid and acetaminophen, the biosensor has shown high sensitivity and good anti‐interferent ability in the detection of cholesterol. The effect of the pH value of the detection solution on the response of the biosensor was also investigated. A linear range up to 6.0 mM has been observed for the biosensor with a detection limit of 0.2 mM. The apparent Michaelis‐Menten constant and the maximum response current density were calculated to be 7.17 mM and 7.32 μA cm?2, respectively.  相似文献   

2.
A novel biosensor for hydrogen peroxide was prepared by immobilizing horseradish peroxidase (HPR) on newly synthesized dendritic silver/silicon dioxide nanocomposites, which were coated on a glassy carbon electrode. The modified electrode was characterized with XPS, SEM, and electrochemical methods. This biosensor showed a very fast amperometric response to hydrogen peroxide with a linear range from 0.7 to 120 μM, a limit of detection of 0.05 μM and a sensitivity of 1.02 mA mM?1 cm?2. The Michaelis‐Menten constant of the immobilized HRP was estimated to be 0.21 mM, indicating a high affinity of the HRP to H2O2 without loss of enzymatic activity. The preparation of the proposed biosensor was convenient, and it showed high sensitivity and good stability.  相似文献   

3.
A novel method to fabricate a third‐generation hydrogen peroxide biosensor was reported. The electrode was first derivatized by electrochemical reduction of in situ generated 4‐carboxyphenyl diazonium salt (4‐CPDS) in acidic aqueous solution yielded stable 4‐carboxyphenyl (4‐CP) layer. The horseradish peroxidase (HRP) enzyme was then covalently immobilized by amidation between NH2 terminus of enzyme and COOH terminus of 4‐CP film making use of the carbodiimide chemistry. Electrodeposition conditions used to control electrode functionalization density and film electron transfer kinetics were assessed by chronoamperometry and electrochemical impedance spectroscopy. The immobilized HRP displayed excellent electrocatalytic activity towards the reduction of hydrogen peroxide (H2O2) without any mediators. The effect of various operational parameters was explored for optimum analytical performance. The reported biosensor exhibited fast amperometric response (within 5 s) to H2O2. The detection limit of the biosensor was 5 μM, and linear range was from 20 μM to 20 mM. Furthermore, the biosensor exhibited high sensitivity, good reproducibility, and long‐term stability.  相似文献   

4.
《Electroanalysis》2017,29(6):1518-1523
A sensitive and selective amperometric H2O2 biosensor was obtained by utilizing the electrodeposition of Pt flowers on iron oxide‐reduced graphene oxide (Fe3O4/rGO) nanocomposite modified glassy carbon electrode (GCE). The morphology of Fe3O4/rGO and Pt/Fe3O4/rGO was characterized by transmission electron microscopy (TEM) and scanning electron microscopy (SEM), respectively. The step‐wise modification and the electrochemical characteristics of the resulting biosensor were characterized by cyclic voltammetry (CV) and chronoamperometry methods. Thanks to the fast electron transfer at the Pt/Fe3O4/rGO electrode interface, the developed biosensor exhibits a fast and linear amperometric response upon H2O2. The linear range of Pt/Fe3O4/rGO is 0.1∼2.4 mM (R2=0.998), with a sensitivity of 6.875 μA/mM and a detection limit of 1.58 μM (S/N=3). In addition, the prepared biosensor also provides good anti‐interferent ability and long‐term stability due to the favorable biocompatibility of the electrode interface. The proposed sensor will become a reliable and effective tool for monitoring and sensing the H2O2 in complicate environment.  相似文献   

5.
《Electroanalysis》2003,15(3):219-224
A novel hydrogen peroxide biosensor has been constructed based on the characteristics of the carbon nanotube. The multiwall carbon nanotube (MWNT) was used as a coimmobilization matrix to incorporate horseradish peroxidase (HRP) and electron transfer mediator methylene blue (MB) onto a glassy carbon electrode surface. Cyclic voltammetry and amperometric measurements were employed to demonstrate the feasibility of methylene blue as an electron carrier between the immobilized peroxidase and the surface of glassy carbon electrode. The amperometric response of this resulting biosensor to H2O2 shows a linear relation in the range from 4 μM to 2 mM. The detection limit was 1 μM when the signal to noise ratio is 3. The presence of dopamine and ascorbic acid hardly affects the sensitive determination of H2O2. This biosensor also possesses very good stability and reproducibility.  相似文献   

6.
A novel amperometric glucose biosensor based on layer‐by‐layer (LbL) electrostatic adsorption of glucose oxidase (GOx) and dendrimer‐encapsulated Pt nanoparticles (Pt‐DENs) on multiwalled carbon nanotubes (CNTs) was described. Anionic GOx was immobilized on the negatively charged CNTs surface by alternatively assembling a cationic Pt‐DENs layer and an anionic GOx layer. Transmission electron microscopy images and ζ‐potentials proved the formation of layer‐by‐layer nanostructures on carboxyl‐functionalized CNTs. LbL technique provided a favorable microenvironment to keep the bioactivity of GOx and prevent enzyme molecule leakage. The excellent electrocatalytic activity of CNTs and Pt‐DENs toward H2O2 and special three‐dimensional structure of the enzyme electrode resulted in good characteristics such as a low detection limit of 2.5 μM, a wide linear range of 5 μM–0.65 mM, a short response time (within 5 s), and high sensitivity (30.64 μA mM?1 cm?2) and stability (80% remains after 30 days).  相似文献   

7.
Urchin‐like Ag nanowires were prepared by reacting AgNO3(aq) with Cu metal in the presence of cetyltrimethylammonium chloride and HNO3(aq) on a screen printed carbon electrode at room temperature. The diameters of the nanowires were about 100 nm, while the lengths were up to 10 μm. Cyclic voltammetric experiments using the Ag nanowires as the working electrode showed electrocatalytic H2O2 reduction. The electrode exhibited a high sensitivity of 4705 μA mM‐1 mg‐1 cm‐2 from 50 μM to 10.35 mM and a measurable detection limit of 10 μM in amperometric detection. This is the first report on Ag NWs for non‐enzymatic H2O2 sensing.  相似文献   

8.
A hemoglobin‐titanate composite based biosensor was chosen for determination of H2O2 in an acidic medium. CV results of the Hb‐titanate modified pyrolytic graphite electrode showed a pair of well‐defined, quasi‐reversible redox peaks centered at ?246 mV (vs. Ag/AgCl) in a pH 5.0 HAc‐NaAc buffer solution. The modified electrode exhibited good electrocatalytic response for monitoring H2O2 and had a large linear detection range from 20 μM to 3.2 mM with a detection limit of 8 μM (S/N=3) and a sensitivity of 29.7 mA M?1 cm?2 in the pH 5.0 solution. The biosensor also possessed good long term storage stability.  相似文献   

9.
A simple layer‐by‐layer (LBL) assembly strategy was established for constructing a novel reagentless biosensor based on a nanocomposite of methylene blue multiwalled carbon nanotubes (MB‐MWNTs). A nanocomposite of MB‐MWNTs was obtained by direct premixing and possessed good dispersion in barbital‐HCl buffer. Through electrostatic interactions, the nanocomposite of MB‐MWNTs could alternately be assembled with horseradish peroxidase (HRP) on the Au electrode modified with precursor films. UV/Vis spectra and scanning electron microscopy (SEM) were applied to reveal the formation of the nanocomposite of MB‐MWNTs. The LBL assembly process was also verified by electrochemical impedance spectroscopy (EIS). The MB is a well‐established mediator and efficiently facilitated the electron shuttle between the HRP and the electrode, as demonstrated by the cyclic voltammetry (CV) measurements. The as‐prepared reagentless biosensor exhibited a fast response for the determination of hydrogen peroxide (H2O2) and reached 95% of the steady‐state current within 3 s. It was found that the linear response range of the reagentless biosensor for H2O2 was from 4.0 μM to 3.78 mM with a detection limit of 1.0 μM and a sensitivity of 22.5 μA mM−1. The biosensor exhibited a high reproducibility and stability.  相似文献   

10.
Studies on the immobilization of acetylcholinesterase onto a SAM gold electrode and the use of the fabricated biosensor for the determination of carbaryl and parathion are presented. The influence of pH, ionic strength, enzyme loading and concentration of glutaraldehyde on the response of the biosensor was investigated . The amperometric biosensor developed in this study provided linearity to parathion and carbaryl in the 2.0 a 30.0×10?6 mol L?1 concentration range. The detection limits under the optimum working conditions were found to be 9.3 μg L?1 for parathion and 9.0 μg L?1 for carbaryl. The enzyme electrode was found to be stable for 7 days.  相似文献   

11.
An amperometric tyramine biosensor based on poly‐L‐lysine (PLL) and Fe3O4 nanoparticles (Fe3O4NP) modified screen printed carbon electrode (SPCE) was developed. PLL was formed on the SPCE by the electropolymerization of L‐lysine. Subsequently, Fe3O4NP suspension prepared in chitosan (CH) solution was casted onto the PLL/SPCE. Tyrosinase (Ty) enzyme was immobilized onto the modified Fe3O4?CH/PLL/SPCE and the electrode was coated with Nafion to fabricate the Ty/Fe3O4?CH/PLL/SPCE. Different techniques including scanning electron microscopy, chronoamperometry (i–t curve), cyclic voltammetry and electrochemical impedance spectroscopy were utilized to study the fabrication processes, electrochemical characteristics and performance parameters of the biosensor. The analytical performance of the tyramine biosensor was evaluated with respect to linear range, sensitivity, limit of detection, repeatability and reproducibility. The response of the biosensor to tyramine was linear between 4.9×10?7–6.3×10?5 M with a detection limit of 7.5×10?8 M and sensitivity of 71.36 μA mM?1 (595 μA mM?1 cm?2). The application of the developed biosensor for the determination of tyramine was successfully tested in cheese sample and mean analytical recovery of added tyramine in cheese extract was calculated as 101.2±2.1 %. The presented tyramine biosensor is a promising approach for tyramine analysis in real samples due to its high sensitivity, rapid response and easy fabrication.  相似文献   

12.
《Electroanalysis》2006,18(3):259-266
In this paper, a new strategy for constructing a mediator‐type amperometric hydrogen peroxide (H2O2) microbiosensor was described. An electropolymerized thionine film (PTH) was deposited directly onto a gold electrode surface. The resulting redox film was extremely thin, adhered well onto a substrate (electrode), and had a highly cross‐linked network structure. Consequently, horseradish peroxidase (HRP) was successfully immobilized on nanometer‐sized Au colloids, which were supported by thiol‐tailed groups of 11‐mercaptoundecanoic acid (11‐MUA) monolayer covalently bound onto PTH film. With the aid of the PTH mediator, HRP‐labeled Au colloids microbiosensor displayed excellent electrocatalytical response to the reduction of H2O2. This matrix showed a biocompatible microenvironment for retaining the native activity of the covalent HRP and a very low mass transport barrier to the substrate, which provided a fast amperometric response to H2O2. The proposed H2O2 microbiosensor exhibited linear range of 3.5 μM–0.7 mM with a detection limit of 0.05 μM (S/N=3). The response showed a Michaelis‐Menten behavior at larger H2O2 concentrations. The KMapp value for the biosensors based on 24 nm Au colloids was found to be 47 μM, which demonstrated that HRP immobilized on Au colloids exhibited a high affinity to H2O2 with no loss of enzymatic activity. This microbiosensor possessed good analytical performance and storage stability.  相似文献   

13.
《Electroanalysis》2004,16(4):268-274
An amperometric method for the determination of the neurotoxic amino acid β‐N‐oxalyl‐L ‐α,β‐diaminopropionic acid (β‐ODAP) using a screen printed carbon electrode (SPCE) is reported. The electrode material was bulk‐modified with manganese dioxide and used as a detector in flow injection analysis (FIA). The enzyme glutamate oxidase (GlOx) was immobilized in a Nafion‐film on the electrode surface. The performance of the biosensor was optimized using glutamate as an analyte. Optimum parameters were found as: operational potential 440 mV (vs. Ag/AgCl), flow rate 0.2 mL min?1, and carrier composition 0.1 mol L?1 phosphate buffer (pH 7.75). The same conditions were used for the determination of β‐ODAP. The signal was linear within the concentration range 53–855 μmol L?1 glutamate and 195–1950 μmol L?1 β‐ODAP. Detection limits (as 3σ value) for both analytes were 9.12 and 111.0 μmol L?1, respectively, with corresponding relative standard deviations of 3.3 and 4.5%. The biosensor retained more than 73% of its activity after 40 days of on‐line use.  相似文献   

14.
A mediator‐free choline biosensor was developed using the electrochemically assisted sol‐gel deposition on gold screen‐printed electrodes. The addition of 12 mM of cationic surfactant CTAB in silica sol allowed enhancing the stability of the sensor. The modified electrode demonstrated catalytic activity and stable amperometric response to choline for over 3 weeks of exploitation with the sensitivity of 6 µA mM?1 and LOD of 6 µM. The interference of ascorbic acid was reduced by pretreating the analyzed solution with MnO2 powder. The application of the sensor with the purpose of identifying choline in the baby milk demonstrated satisfactory metrological characteristics.  相似文献   

15.
《Electroanalysis》2017,29(11):2507-2515
In the present study, a novel enzymatic glucose biosensor using glucose oxidase (GOx) immobilized into (3‐aminopropyl) triethoxysilane (APTES) functionalized reduced graphene oxide (rGO‐APTES) and hydrogen peroxide sensor based on rGO‐APTES modified glassy carbon (GC) electrode were fabricated. Nafion (Nf) was used as a protective membrane. For the characterization of the composites, Fourier transform infrared spectroscopy (FTIR), X‐ray powder diffractometer (XRD), and transmission electron microscopy (TEM) were used. The electrochemical properties of the modified electrodes were investigated using electrochemical impedance spectroscopy, cyclic voltammetry, and amperometry. The resulting Nf/rGO‐APTES/GOx/GC and Nf/rGO‐APTES/GC composites showed good electrocatalytical activity toward glucose and H2O2, respectively. The Nf/rGO‐APTES/GC electrode exhibited a linear range of H2O2 concentration from 0.05 to 15.25 mM with a detection limit (LOD) of 0.017 mM and sensitivity of 124.87 μA mM−1 cm−2. The Nf/rGO‐APTES/GOx/GC electrode showed a linear range of glucose from 0.02 to 4.340 mM with a LOD of 9 μM and sensitivity of 75.26 μA mM−1 cm−2. Also, the sensor and biosensor had notable selectivity, repeatability, reproducibility, and storage stability.  相似文献   

16.
The redox mediator Meldola blue (MB) was entrapped into two polymers, poly‐1,2‐diaminobenzene (p‐DAB) and poly‐3,4‐ethylenedioxythiophene (p‐EDOT) by potential cycling and films were applied to NADH oxidation with subsequent glutamate detection using immobilized glutamate dehydrogenase. Both polymer films were tested for electrocatalysis of NADH using amperometry at Eapp=0.1 V vs. Ag/AgCl and similar response characteristics were obtained with sensitivity values of 6.1 nA μM?1, linear range up to 0.5 mM (R2=0.9972) and LOD of 50 μM. Subsequent amperometric determination of glutamate resulted in sensitivity 0.7 nA μM?1, linearity 0–100 μM and detection limit of 2 μM glutamate.  相似文献   

17.
A new convenient strategy to fabricate a third‐generation hydrogen peroxide biosensor was described. The screen‐printed carbon electrode (SPCE) was first modified with a layer of 4‐nitrophenyl assembled from the 4‐nitroaniline diazonium salt synthesized in situ in acidic aqueous solution. Next, the nitro groups were converted to amines followed by crosslinking to the horseradish peroxidase (HRP) by glutaraldehyde. The redox chemistry of the active center of the HRP was observed and the HRP‐modified electrode displayed electrocatalytic activity towards the reduction of hydrogen peroxide (H2O2) without any mediators. H2O2 was determined in a linear range from 5.0 μM to 50.0 μM, with a detection limit of 1.0 μM. Furthermore, the biosensor exhibited fast amperometric response, good reproducibility and long‐term stability.  相似文献   

18.
In this study, a new glucose biosensor was fabricated by immobilizing glucose oxidase (GOx) on platinum nanoparticles (Pt NPs) decorated reduced graphene oxide (rGO)/Zn‐MOF‐74 hybrid nanomaterial. Herein, the biosensor fused the advantages of rGO with those of porous Zn‐MOF and conductive Pt NPs. This has not only enlarged the surface area and porosity for the efficient GOx immobilization and faster mass transport, but also provided favorable electrochemical features such as high current density, remarkable electron mobility through metal nanoparticles, and improved electron transfer between the components. The GOx‐rGO/Pt NPs@Zn‐MOF‐74 coated electrode displayed a linear measurement range for glucose from 0.006 to 6 mM, with a detection limit of 1.8 μM (S/N: 3) and sensitivity of 64.51 μA mM?1 cm?2. The amperometric response of the enzyme biosensor demonstrated the typical behavior of Michaelis‐Menten kinetics. The obtained satisfying sensitivity and measurement range enabled fast and accurate glucose measurement in cherry juice using the fabricated biosensor. The water‐stable Zn‐MOF‐74 demonstrated higher enzyme loading capacity and can be potent supporting material for biosensor construction.  相似文献   

19.
Here we report the first mediated pain free microneedle‐based biosensor array for the continuous and simultaneous monitoring of lactate and glucose in artificial interstitial fluid (ISF). The gold surface of the microneedles has been modified by electrodeposition of Au‐multiwalled carbon nanotubes (MWCNTs) and successively by electropolymerization of the redox mediator, methylene blue (MB). Functionalization of the Au‐MWCNTs/polyMB platform with the lactate oxidase (LOX) enzyme (working electrode 1) and with the FAD‐Glucose dehydrogenase (FADGDH) enzyme (working electrode 2) enabled the continuous monitoring of lactate and glucose in the artificial ISF. The lactate biosensor exhibited a high sensitivity (797.4±38.1 μA cm?2 mM?1), a good linear range (10–100 μM) with a detection limit of 3 μM. The performance of the glucose biosensor were also good with a sensitivity of 405.2±24.1 μA cm?2 mM?1, a linear range between 0.05 and 5 mM and a detection limit of 7 μM. The biosensor array was tested to detect the amount of lactate generated after 100 minutes of cycling exercise (12 mM) and of glucose after a normal meal for a healthy patient (10 mM). The results reveal that the new microneedles‐based biosensor array seems to be a promising tool for the development of real‐time wearable devices with a variety of sport medicine and clinical care applications.  相似文献   

20.
唐明宇袁若  柴雅琴 《中国化学》2006,24(11):1575-1580
The third generation amperometric biosensor for the determination of hydrogen peroxide (H2O2) has been described. For the fabrication of biosensor, o-aminobenzoic acid (oABA) was first electropolymerized on the surface of platinum (Pt) electrode as an electrostatic repulsion layer to reject interferences. Horseradish peroxidase (HRP) absorbed by nano-scaled particulate gold (nano-Au) was immobilized on the electrode modified with polymerized o-aminobenzoic acid (poABA) with L-cysteine as a linker to prepare a biosensor for the detection of H2O2. Amperometric detection of H2O2 was realized at a potential of +20 mV versus SCE. The resulting biosensor exhibited fast response, excellent reproducibility and sensibility, expanded linear range and low interferences. Temperature and pH dependence and stability of the sensor were investigated. The optimal sensor gave a linear response in the range of 2.99×10^-6 to 3.55×10^-3 mol·L^-1 to H2O2 with a sensibility of 0.0177 A·L^-1·mol^-1 and a detection limit (S/N = 3) of 4.3×10^-7 mol·L^-1. The biosensor demonstrated a 95% response within less than 10 s.  相似文献   