首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Kamoda S  Kakehi K 《Electrophoresis》2008,29(17):3595-3604
The development of monoclonal antibody (mAb) pharmaceuticals has rapidly generated in this decade, and there are currently 23 FDA-approved mAb pharmaceuticals. Carbohydrate chains in mAb pharmaceuticals play important roles for the expression of their biological activities such as antibody-dependent cellular cytotoxicity, whereas the oligosaccharide profile is easily changed depending on the manufacturing conditions. Therefore, the evaluation of carbohydrate chains in detail is quite important for quality control in the development of mAb from early phases, but oligosaccharides in mAb have high heterogeneity and full characterization of oligosaccharide moiety in mAb has been a challenging target. Capillary electrophoresis (CE) is a powerful tool for the evaluation of glycan occupancy and oligosaccharide profile. This review focuses mainly on the application of CE to the analytical studies on glycosylation in mAb pharmaceuticals developed in our laboratory. The related techniques including the full-image microchip isoelectric focusing and the newly developed mass spectrometry technologies are also shown. The combination of the techniques described in this review will be a good guide for the evaluation of glycosylation for quality assurance of antibody pharmaceuticals by CE from the early stage of the development to the marketing stage.  相似文献   

2.
Zero-valent iron (Fe0) has recently been proposed as a potential candidate for the degradation of pharmaceuticals, because Fe0 can release dissolved iron species, activate molecular oxygen, and react with oxidant species. Additionally, due to its small particle size and large surface area, this catalyst can provide better degradation results, compared to traditional processes. This work focuses on the elimination of pharmaceuticals present in different water matrices, considering the potential harm that these substances can cause in the environment. The mechanisms of pharmaceutical removal using Fe0 particles include reduction, adsorption, precipitation, and oxidation processes. Most studies have focused on oxidation processes in the presence of Fe0 and radicals derived from oxidants such as hydrogen peroxide (H2O2), ozone (O3), peroxysulfate (SO52−), peroxodisulfate (S2O82−), and oxygen (O2). Most of the results have shown that high percentages of pharmaceuticals can be removed, degraded, and mineralized. The mechanisms of oxidation and the parameters that influence the degradation of pharmaceuticals, as well as the possible degradation pathways, are discussed here. This review provides information on trends of different processes that use Fe0, considering aspects such as particle size, type of matrix, the pharmaceuticals studied, and the results obtained that can improve understanding of new advances in the field of advanced oxidation processes (AOPs) for the degradation and elimination of pharmaceuticals.  相似文献   

3.
Target-specific biomolecules, monoclonal antibodies (mAb), proteins, and protein fragments are known to have high specificity and affinity for receptors associated with tumors and other pathological conditions. However, the large biomolecules have relatively intermediate to long circulation half-lives (>day) and tumor localization times. Combining superior target specificity of mAbs and high sensitivity and resolution of the PET (Positron Emission Tomography) imaging technique has created a paradigm-shifting imaging modality, ImmunoPET. In addition to metallic PET radionuclides, 124I is an attractive radionuclide for radiolabeling of mAbs as potential immunoPET imaging pharmaceuticals due to its physical properties (decay characteristics and half-life), easy and routine production by cyclotrons, and well-established methodologies for radioiodination. The objective of this report is to provide a comprehensive review of the physical properties of iodine and iodine radionuclides, production processes of 124I, various 124I-labeling methodologies for large biomolecules, mAbs, and the development of 124I-labeled immunoPET imaging pharmaceuticals for various cancer targets in preclinical and clinical environments. A summary of several production processes, including 123Te(d,n)124I, 124Te(d,2n)124I, 121Sb(α,n)124I, 123Sb(α,3n)124I, 123Sb(3He,2n)124I, natSb(α, xn)124I, natSb(3He,n)124I reactions, a detailed overview of the 124Te(p,n)124I reaction (including target selection, preparation, processing, and recovery of 124I), and a fully automated process that can be scaled up for GMP (Good Manufacturing Practices) production of large quantities of 124I is provided. Direct, using inorganic and organic oxidizing agents and enzyme catalysis, and indirect, using prosthetic groups, 124I-labeling techniques have been discussed. Significant research has been conducted, in more than the last two decades, in the development of 124I-labeled immunoPET imaging pharmaceuticals for target-specific cancer detection. Details of preclinical and clinical evaluations of the potential 124I-labeled immunoPET imaging pharmaceuticals are described here.  相似文献   

4.
The ever-growing number of emerging micropollutants such as pharmaceuticals requests rapid and sensitive full-spectrum analytical techniques. Time-of-flight high-resolution mass spectrometry (TOF-HRMS) is a promising alternative for the state-of-the-art tandem mass spectrometry instruments because of its ability to simultaneously screen for a virtually unlimited number of suspect analytes and to perform target quantification. The challenge for such suspect screening is to develop a strategy, which minimizes the false-negative rate without restraining numerous false-positives. At the same time, omitting laborious sample enrichment through large-volume injection ultra-performance liquid chromatography (LVI-UPLC) avoids selective preconcentration. A suspect screening strategy was developed using LVI-UPLC-TOF-MS aiming the detection of 69 multi-class pharmaceuticals in surface water without the a priori availability of analytical standards. As a novel approach, the screening takes into account the signal-intensity-dependent accurate mass error of TOF-MS, hereby restraining 95 % of the measured suspect pharmaceuticals present in surface water. Application on five Belgian river water samples showed the potential of the suspect screening approach, as exemplified by a false-positive rate not higher than 15 % and given that 30 out of 37 restrained suspect compounds were confirmed by the retention time of analytical standards. Subsequently, this paper discusses the validation and applicability of the LVI-UPLC full-spectrum HRMS method for target quantification of the 69 pharmaceuticals in surface water. Analysis of five Belgian river water samples revealed the occurrence of 17 pharmaceuticals in a concentration range of 17 ng L?1 up to 3.1 μg L?1.
Figure
The variability of the mass error decreases inversely with the log-transformed signal intensity. The signal-intensity-dependent accurate mass error was taken into account in a new suspect screening assuring that 95 % of the measured compounds are restrained  相似文献   

5.
An improved analytical method for determination of human pharmaceuticals in natural and wastewaters with ng L−1 sensitivity is presented. The method is applicable to pharmaceuticals from a wide range of therapeutic classes including antibiotics, analgesics, anti-inflammatories and anti-cancer compounds. Pharmaceuticals were extracted from waters using solid-phase extraction, and after concentration, analysed by high performance liquid chromatography with tandem mass spectrometric detection (HPLC-MS/MS). Identification of each compound was secured using retention time and by the selected reaction monitoring of two transitions, one of which was additionally used for quantification. Limits of detection ranged from 0.03 to 0.96 ng L−1 and were up to two orders of magnitude lower than those of previously published methods. The method was validated using spiked samples prepared from tap, river and sea water as well as wastewater effluents, collected from the North of Scotland. Analysis of wastewater effluents revealed the presence of mefenamic acid, ibuprofen, erythromycin, diclofenac and trimethoprim. None of the selected pharmaceuticals were detected in river, tap or sea water samples.  相似文献   

6.
The presence of pharmaceuticals in the aquatic environment is an ever-increasing issue of concern as they are specifically designed to target specific metabolic and molecular pathways in organisms, and they may have the potential for unintended effects on nontarget species. Information on the presence of pharmaceuticals in biota is still scarce, but the scientific literature on the subject has established the possibility of bioaccumulation in exposed aquatic organisms through other environmental compartments. However, few studies have correlated both bioaccumulation of pharmaceutical compounds and the consequent effects. Analytical methodology to detect pharmaceuticals at trace quantities in biota has advanced significantly in the last few years. Nonetheless, there are still unresolved analytical challenges associated with the complexity of biological matrices, which require exhaustive extraction and purification steps, and highly sensitive and selective detection techniques. This review presents the trends in the analysis of pharmaceuticals in aquatic organisms in the last decade, recent data about the occurrence of these compounds in natural biota, and the environmental implications that chronic exposure could have on aquatic wildlife.  相似文献   

7.
Laboratory experimentation is essential for our understanding of the fate and behaviour of pollutants. Many analytical techniques exist, but they all have disadvantages either in terms of sensitivity or of selectivity. The number of samples that can be analysed, the low volume of samples available during the experiment and the need to identify different degradates are all obstacles that new techniques are able to overcome. The work presented here summarizes progress in the field of metrology as concerns online solid phase extraction technology coupled with liquid chromatography followed by tandem mass spectrometry detection. Recently developed analytical techniques were validated for both 18 pesticides and their degradates and 17 pharmaceuticals and their degradates. Limits of quantification from 20 to 70 ng L?1 for pharmaceuticals and from 15 to 25 ng L?1 for pesticides and metabolites have been obtained, with linearity range up to 1 μg L?1. The limits of quantification of a few nanograms per litre, the possibility of working on less than 1 mL of sample and the simultaneous quantification of the target products and their transformation products are all advantages that are demonstrated by two environmental applications. The first application concerns the evaluation of ecotoxicological effects of pesticides on aquatic organisms exposed in mesocosms. The second application aims to determine the adsorption constants of pharmaceutical molecules on soils and river sediments. For both applications, the robustness, range of linearity and limit of quantification of the developed analytical methods satisfy the requirements for laboratory experiments conducted under controlled conditions. Specific constraints generated by this type of experiment (adding CaCl2 for the adsorption study and filtration of the water coming from the mesocosms) were not found to limit the use of online SPE. These two preliminary studies show that new experimental fields are possible thanks to online solid phase extraction coupled with liquid chromatography.  相似文献   

8.
The occurrence and seasonal distribution of 14 pharmaceutical substances of different classes were investigated in two drinking water treatment plants (DWTPs) supplied by the two main Italian rivers, the Po and the Adige (Northern Italy). The therapeutic categories of the selected pharmaceuticals included anti-inflammatory drugs, β-blockers, lipid regulators, diuretics, anti-epileptics, antibiotics and a steroidal hormone. The named compounds were assessed in samples collected from the river water inlet and after each purification stage (sand filtration, ozone treatment, granular active carbon (GAC)). Six of the 14 selected pharmaceuticals were found in all analysed samples, with concentration levels ranging from 1?ng?l?1 for atorvastatin to 69?ng?l?1 for atenolol in the drinking water produced. The granular active carbon stage resulted the most efficient in eliminating the examined chemicals from the water (removal range: 12–95%, average: 68%), while the sand filtration stage resulted the least effective treatment (removal range: 4–37%, average: 13%). The observed differences between winter and summer conditions, in terms of residual concentrations and number of detected analytes, seemed to depend mainly on the quality of the river water supplies. To the best of our knowledge, these are the first reported data on the presence of pharmaceuticals in drinking water obtained from the water treatment of these two rivers.  相似文献   

9.
Duloxetine (DLX) is a widely used antidepressant drug belonging to the class of selective serotonin and norepinephrine reuptake inhibitors (SNRIs); its efficacy has been demonstrated in the treatment of not only major depressive disorders but also diabetic neuropathic pain, generalized anxiety disorder, fibromyalgia or stress urinary incontinence. It is a chiral substance and is used in therapy in the form of the enantiopure S‐DLX, which is twice as active as R‐DLX. Several methods have been published for the achiral and chiral determination of DLX in pharmaceuticals, biological materials and environmental samples, the majority using liquid chromatography and capillary electrophoresis coupled with different detection techniques (UV detection, fluorescence, mass spectrometry). The aim of the current review is to provide a systematic survey of the analytical techniques used for the determination of DLX from different matrices.  相似文献   

10.
Traditional methods for protein kinase (PK) assay are mainly based on use of 32P-labeled adenosine triphosphate (ATP); applications of such methods are, however, hampered by radioactive waste and short half-life of 32P-labeled ATP. Therefore non-radioactive methods, such as fluorescence detection techniques are good alternative. In this review, we describe the principles of four fluorescence techniques (fluorescence intensity endpoint measurement, fluorescence resonance energy transfer (FRET), fluorescence polarization (FP), and fluorescence lifetime imaging) and provide an overview of applications of these fluorescence detection techniques in protein kinase assay, underlining their relative advantages and limitations. Research trends in this field are also highlighted. Figure Schematic representation of kinase assay based on direct fluorescence polarization measurements. The fluorescent peptide, on phosphorylation by kinase, binds to a phosphospecific antibody, which leads to a high FP value  相似文献   

11.
This review with 60 references describes a unique path to miniaturisation, that is, the use of acoustic levitation in analytical and bioanalytical chemistry applications. Levitation of small volumes of sample by means of a levitation technique can be used as a way to avoid solid walls around the sample, thus circumventing the main problem of miniaturisation, the unfavourable surface-to-volume ratio. Different techniques for sample levitation have been developed and improved. Of the levitation techniques described, acoustic or ultrasonic levitation fulfils all requirements for analytical chemistry applications. This technique has previously been used to study properties of molten materials and the equilibrium shape and stability of liquid drops. Temperature and mass transfer in levitated drops have also been described, as have crystallisation and microgravity applications.The airborne analytical system described here is equipped with different and exchangeable remote detection systems. The levitated drops are normally in the 100 nL–2 L volume range and additions to the levitated drop can be made in the pL-volume range.The use of levitated drops in analytical and bioanalytical chemistry offers several benefits. Several remote detection systems are compatible with acoustic levitation, including fluorescence imaging detection, right angle light scattering, Raman spectroscopy, and X-ray diffraction. Applications include liquid/liquid extractions, solvent exchange, analyte enrichment, single-cell analysis, cell–cell communication studies, precipitation screening of proteins to establish nucleation conditions, and crystallisation of proteins and pharmaceuticals.  相似文献   

12.
Capillary electrophoresis is a powerful technique for the analysis of polar chiral compounds and has been widely accepted for analytical enantioseparations of drug compounds in pharmaceuticals and biological media. In addition, many mechanistic studies have been conducted in an attempt to rationalize enantioseparations in combination with spectroscopic and computational techniques. The present review will focus on recent examples of mechanistic aspects and summarize recent applications of stereoselective pharmaceutical and biomedical analysis published between January 2017 and November 2020. Various separation modes including electrokinetic chromatography in combination with several detection modes including laser-induced fluorescence, mass spectrometry and contactless conductivity detection will be discussed. A general trend also observed in other analytical techniques is the application of quality by design principles in method development and optimization.  相似文献   

13.
Ambient ionization mass spectrometry: a tutorial   总被引:4,自引:0,他引:4  
Ambient ionization is a set of mass spectrometric ionization techniques performed under ambient conditions that allows the direct analysis of sample surfaces with little or no sample pretreatment. Using combinations of different types of sample introduction systems and ionization methods, several novel techniques have been developed over the last few years with many applications (e.g., food safety screening; detection of pharmaceuticals and drug abuse; monitoring of environmental pollutants; detection of explosives for antiterrorism and forensics; characterization of biological compounds for proteomics and metabolomics; molecular imaging analysis; and monitoring chemical and biochemical reactions). Electrospray ionization and atmospheric pressure chemical ionization are the two main ionization principles most commonly used in ambient ionization mass spectrometry. This tutorial paper provides a review of the publications related to ambient ionization techniques. We describe and compare the underlying principles of operation, ionization processes, detecting mass ranges, sensitivity, and representative applications of these techniques.  相似文献   

14.
Wang A  Fang Y 《Electrophoresis》2000,21(7):1281-1290
As a high efficiency separation technique, capillary electrophoresis has been widely used in various fields of analytical science. This review discusses the applications of electrochemical detection systems combined with capillary electrophoresis in pharmaceutical and biomedical analysis. These detection methods mainly involve amperometric detection but also include conductivity detection and potentiometric detection. Its applications in the field are divided into six parts, including catechol compounds, thiols, amino acids and peptides, carbohydrates, general pharmaceuticals, and other related compounds. A relatively detailed discussion is described for each compound under the current studied. On this basis, we have suggested several conceivable directions for capillary electrophoresis with electrochemical detection in the future.  相似文献   

15.
Recent developments in desorption/ionisation mass spectrometry techniques have made their application to biological analysis a realistic and successful proposition. Developments in primary ion source technology, mainly through the advent of polyatomic ion beams, have meant that the technique of secondary ion mass spectrometry (SIMS) can now access the depths of information required to allow biological imaging to be a viable option.Here the role of the primary ion C60+ is assessed with regard to molecular imaging of lipids and pharmaceuticals within tissue sections. High secondary ion yields and low surface damage accumulation are demonstrated on both model and real biological samples, indicating the high secondary ion efficiency afforded to the analyst by this primary ion when compared to other cluster ion beams used in imaging. The newly developed 40 keV C60+ ion source allows the beam to be focused such that high resolution imaging is demonstrated on a tissue sample, and the greater yields allow the molecular signal from the drug raclopride to be imaged within tissue section following in vivo dosing.The localisation shown for this drug alludes to issues regarding the chemical environment affecting the ionisation probability of the molecule; the importance of this effect is demonstrated with model systems and the possibility of using laser post-ionisation as a method for reducing this consequence of bio-sample complexity is demonstrated and discussed.  相似文献   

16.
Three new hypercrosslinked polymers with hydrophilic character arising from hydroxyl moieties in their skeletons have been prepared in microsphere format and applied to the off-line solid-phase extraction (SPE) of polar compounds from water samples. For sample volumes of 1000 ml, the recoveries of various polar pesticides, such as oxamyl, methomyl, selected phenolic compounds, as well as some pharmaceuticals, were close to 90%. The HXLPP-polar polymer with the best performance characteristics was applied to real samples. Its performance was also compared to commercially available sorbents, such as LiChrolut EN (hydrophobic, hypercrosslinked), Oasis HLB (hydrophilic, macroporous) and Isolute ENV+ (hydrophilic, hypercrosslinked); the new sorbent out-performed the commercially available sorbents. The polymer was applied successfully in off-line SPE of river water samples followed by liquid chromatography and ultraviolet detection, providing a good linear range and detection limits of 0.2 μg l−1 for the majority of the compounds, with the exception of oxamyl, methomyl, guaiacol and salicylic acid where the detection limit was 0.5 μg l−1.  相似文献   

17.
Method development and applications of hyphenated techniques as tools for speciation analysis of metal-based pharmaceuticals are summarized within this review. Advantages and limitations of the separation modes-high-performance liquid chromatography (HPLC), capillary electrophoresis (CE), and gas chromatography (GC)-as well as the detection modes-inductively coupled plasma-mass spectrometry (ICP-MS) and electrospray ionization-mass spectrometry (ESI-MS)-are discussed. ICP-MS detection is found to be advantageous for the quantification of drugs containing metals and other heteroatoms. The species-independent sensitivity and multielement capabilities of ICP-MS allow it to be used for quantification even when species-specific standards are not available, as well as to determine the stoichiometry in metallodrug-biomolecule interactions. Molecular information that is totally destroyed when ICP is applied as ionization source and is therefore not obtainable via ICP-MS detection can be accessed by the complementary technique of ESI-MS. Speciation analysis combining both elemental and molecular information is therefore a powerful tool for the analysis of metal-based pharmaceuticals and their metabolites in body fluids and other relevant matrices.  相似文献   

18.
The interactions of compounds with DNA have been studied since the recognition of the role of nucleic acid in organisms. The design of molecules which specifically interact with DNA sequences allows for the control of the gene expression. Determining the type and strength of such interaction is an indispensable element of pharmaceutical studies. Cognition of the therapeutic action mechanisms is particularly important for designing new drugs. Owing to their sensitivity, simplicity, and low costs, electrochemical methods are increasingly used for this type of research. Compared to other techniques, they require a small number of samples and are characterized by a high reliability. These methods can provide information about the type of interaction and the binding strength, as well as the damage caused by biologically active molecules targeting the cellular DNA. This review paper summarizes the various electrochemical approaches used for the study of the interactions between pharmaceuticals and DNA. The main focus is on the papers from the last decade, with particular attention on the voltammetric techniques. The most preferred experimental approaches, the electrode materials and the new methods of modification are presented. The data on the detection ranges, the binding modes and the binding constant values of pharmaceuticals are summarized. Both the importance of the presented research and the importance of future prospects are discussed.  相似文献   

19.
A semi-automatic flow-based method for the simultaneous determination of 9 pharmaceuticals and 3 hormones in water samples in a single analytical run is proposed. The analytes were retained on a solid-phase extraction sorbent column and 1 μL of the eluate analysed by gas chromatography in combination with electron impact ionization mass spectrometry in the SIM mode. The sorbent used, Oasis-HLB, provided near-quantitative recovery of all analytes. The proposed method was validated with quite good analytical results including low limits of detection (0.01–0.06 ng L−1 for 100 mL of water) and good linearity (r2 > 0.993) throughout the studied concentration ranges. The method provided good accuracy (recoveries of 85–103%) and precision (between- and within-day RSD values less than 7%) in the determination of the pharmaceuticals and hormones in tap, river, pond, well, swimming pool and wastewater.  相似文献   

20.
Ammonium (NH4+) and ammonia (NH3) in aquatic ecosystems are of great interest to environmental scientists because they can be used to study the nitrogen cycle and as water quality indicators. Analytical separation methods developed in recent decades have been used widely to determine NH4+ and NH3 in aqueous solutions. This review presents an overview of state-of-the-art separation methods and analytical techniques for determining NH3/NH4+ in natural water, including chromatographic methods, electrophoretic methods, extraction methods, membrane-based gas diffusion methods, membraneless gas diffusion methods, passive sampling methods, and paper-based analytical methods. Common detection techniques that can be used in conjunction with particular separation methods are described, phase-transfer strategies (liquid-liquid, liquid-solid, liquid-membrane-liquid, and liquid-gas-liquid methods) are highlighted, and the strengths and weaknesses of the separation methods are discussed. The outlook, challenges, and expected future developments in the field of separation methods for determining NH4+ and NH3 in natural water are presented.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号