首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Chu  Chengchao  Li  Long  Li  Shuai  Li  Meng  Ge  Shenguang  Yu  Jinghua  Yan  Mei  Song  Xianrang 《Mikrochimica acta》2013,180(15):1509-1516

We report on an ultrasensitive fluorescence immunoassay for human chorionic gonadotrophin antigen (hCG). It is based on the use of silica nanoparticles coated with a copolymer (prepared from a fluorene, a phenylenediamine, and divinylbenzene; PF@SiO2) that acts as a fluorescent label for the secondary monoclonal antibody to β-hCG antigen. In parallel, Fe3O4 nanoparticles were coated with polyaniline, and these magnetic particles (Fe3O4@PANI) served as a solid support for the primary monoclonal antibody to β-hCG antigen. The PF@SiO2 exhibited strong fluorescence and good dispersibility in water. A fluorescence sandwich immunoassay was developed that enables hCG concentrations to be determined in the 0.01–100 ng·mL−1 concentration range, with a detection limit of 3 pg·mL−1.

Fluorescence detection of prepared immune reagent nano-composites using the fluorescence cell

  相似文献   

2.
We describe here the preparation of carbon-coated Fe3O4 magnetic nanoparticles that were further fabricated into multifunctional core/shell nanoparticles (Fe3O4@C@CNCs) through a layer-by-layer self-assembly process of carbon nanocrystals (CNCs). The nanoparticles were applied in a photoluminescence (PL) immunosensor to detect the carcinoembryonic antigen (CEA), and CEA primary antibody was immobilized onto the surface of the nanoparticles. In addition, CEA secondary antibody and glucose oxidase were covalently bonded to silica nanoparticles. After stepwise immunoreactions, the immunoreagent was injected into the PL cell using a flow-injection PL system. When glucose was injected, hydrogen peroxide was obtained because of glucose oxidase catalysis and quenched the PL of the Fe3O4@C@CNC nanoparticles. The here proposed PL immunosensor allowed us to determine CEA concentrations in the 0.005–50 ng?·?mL-1 concentration range, with a detection limit of 1.8 pg?·?mL-1.
Figure
The Fe3O4@C@CNC was prepared and applied in a CEA immunosensor with the help of a flow-injection photoluminescence system.  相似文献   

3.
Multi-walled carbon nanotubes (MWCNTs) were decorated with magnetite (Fe3O4) nanoparticles and then used to modify a stainless steel electrode. The Fe3O4/MWCNTs composite was characterized by scanning electron microscopy, transmission electron microscopy, Raman spectroscopy and X-ray diffraction patterns. Electrochemical properties of the modified electrode revealed a substantial catalytic activity for the reduction of hydrogen peroxide. The relationship between peak current and the concentration of hydrogen peroxide was linear in the range from 0.06?mmol?L?1 to 0.36?mmol?L?1, and the lowest detectable concentration is 0.01?mmol·L?1 (S/N?=?3). The modified stainless steel electrode displays excellent stability.
Graphical abstract
TEM image of Fe3O4/MWCNTs nanocomposites (left) and SEM image of stainless steel after loading Fe3O4/MWCNTs nanocomposites (right).  相似文献   

4.
We report on a lateral flow immunoassay (LFIA) for influenza A antigen using fluorescently-doped silica nanoparticles as reporters. The method is taking advantage of the high brightness and photostability of silica nanoparticles (doped with the dye Cy5) and the simplicity and rapidity of LFIA. The nucleoprotein of influenza A virion (one of its most abundant structural proteins) was used as a model to demonstrate a performance of the LFIA. Under optimized conditions and by using a portable strip reader, the fluorescence-based LFIA is capable of detecting a recombinant nucleoprotein as low as 250 ng?·?mL-1 using a sample volume of 100 μL, within 30 min, and without interference by other proteins. The successful detection of the nucleoprotein in infected allantoic fluid demonstrated the functionality of the method. By comparison with a commercial influenza A test based on gold nanoparticles as reporters, the system provides an 8-fold better sensitivity.
Figure
A rapid and sensitive lateral flow immunoassay for influenza A antigen was developed using fluorescently-doped silica nanoparticles. A sample containing nucleoprotein as a target analyte induced an accumulation of the fluorescent conjugates at the test spot. The signal was then measured quantitatively using a portable strip reader.  相似文献   

5.
We describe a simple method for the synthesis of highly magnetic and fluorescent bifunctional chitosan nanoparticles (MF-CSNPs). Water-soluble and magnetic Fe3O4-chitosan nanoparticles and CdSe quantum dots capped with thioglycolic acid were incorporated into a chitosan matrix via electrostatic interaction. The optical, magnetic, crystallographic and morphological properties of the new nanoparticles were studied by UV-visible, fluorescence, X-ray diffraction and transmission electron microscopy. In addition, MF-CSNPs are found to be a useful probe for the determination of copper ion which acts as a quencher of fluorescence. The relative fluorescence intensity of MF-CSNPs is linearly related to the concentration of copper ion in the 0.125 to 25 ng·mL-1 concentration range. The MF-CSNPs also are found to adsorb copper ion which therefore can be separated and enriched by manipulating them with an external magnetic field. Before enrichment, the limit of detection (LOD) for copper ion is 120 pg·mL-1, but after enrichment, the LOD is 46 pg·mL-1.
Figure
High magnetic and fluorescent bifunctional chitosan nanoparticles (MF-CSNPs) have been successfully synthesized via electrostatic interaction. MF-CSNPs are shown to represent a quenchable fluorescent probe for the detection of copper ion in water solution.  相似文献   

6.
Homogeneous immunoassays using (red) gold nanoparticles represent an attractive detection scheme because of the option of photometric readout. We have applied oriented immobilization of hen egg immunoglobulin Y (IgY) on gold nanoparticles when developing a homogeneous immunoassay for human IgG. In oriented immobilization, as opposed to random immobilization, the antigen binding capabilities of the antibodies are retained. It is shown that such immunoassay has significantly better sensitivity in comparison with methods based on conventional immobilization of affinity-purified antibodies. It is also shown that hen egg IgY is better suited than rabbit antibodies, because much more antibody can be immobilized on gold nanoparticles without any destabilization, probably because of the more acidic nature of these antibodies. In addition, hen egg IgY can be supplied in higher quantity and can be prepared more easily than IgG from rabbits. Bleeding and slaughtering of animals is not needed. The assay presented here has a wide detection range (30–500?ng?.mL?1) and a limit of detection as low as 30?ng.mL?1 of human IgG.
Figure
Nanoparticles are treated by thiol for formation of monolayer with exposed NH2 groups. IgY molecule is oxidized by periodate for formation of aldehyde group in Fc fragment. Consequent addition of such antibodies to gold nanoparticles results in binding of IgY molecules to gold nanoparticles via Fc fragment providing oriented immobilization.  相似文献   

7.
We report on a novel electrochemical signal amplification strategy for use in immunoassays. The highly responsive immunoelectrode was constructed in the following way: (1) The surface of a gold electrode was covered with a layer single-walled carbon nanotubes dispersed in chitosane functionalized with L-cysteine; (2) Gold nanoparticles containing protein A and anti-alpha-fetoprotein (anti-AFP) were then covalently attached to the surface via the thiol groups of the chitosane. The electrode is then exposed to the analyte (AFP) which then is bound by the antibody. In the next step, a gold-conjugated secondary antibody is added that was prepared in the following way: (1) Horseradish peroxidase was crosslinked and the resulting spheres were coated with hollow gold nanoparticles (hollow Au-NPs) to give nanospheres of ~100 nm in diameter. (2) These were the coated with thionine and, in a last step, with secondary antibody. The use of these materials has several attractive features: The HRP-NPs functionalized with hollow Au-NPs possess a large surface area that can load the large amount of secondary antibody. Thionine (Thi) is highly redox active and improves the intensity of the signal. Carbon nanotubes were used because they possess an excellent electron transfer rate and large surface area. Following incubation of the modified electrode (a) with a sample containing AFP, (b) then with the secondary antibody, and (c) with washing buffer, the electrode is placed in a solution containing H2O2. The HRP in the smart secondary antibody causes the catalytic decomposition of H2O2 and the results in an electrical current that is linearly related to the concentration of AFP in the 0.025 to 5.0 ng mL?1 concentration range. The detection limit for AFP is as low as 8.3 pg mL?1. We believe that this novel kind of immunoassay represents a promising tool for use in sensitive clinical assays.
Graphical Abstract
A novel signal amplification strategy was presented, which is based on the attachment of hollow gold nanoparticles on the surface of immobilized horseradish peroxidase nanospheres. Its application to immunoassay displayed a wide linear response range with low detection limit.  相似文献   

8.
We report on a combination of magnetic solid-phase extraction and spectrophotometric determination of bromate. Cetyltrimethylammonium ion was adsorbed on the surface of phenyl-functionalized silica-coated Fe3O4 nanoparticles (Ph-SiO2@Fe3O4), and these materials served as the sorbent. The effects of surfactant and amount of sorbent, the composition of the desorption solution, the extraction time and temperature were optimized. Under optimized conditions, an enrichment factor of 12 was achieved, and the relative standard deviation is 2.9 % (for n?=?5). The calibration plot covers the 1–50 ng mL?1 range with reasonable linearity (r 2?>?0.998); and the limit of detection is 0.5 ng mL?1. The method is not interfered by ionic compounds commonly found in environmental water samples. It was successfully applied to the determination of bromate in spiked water samples.
Figure
Extraction of bromate ions using surfactant-coated phenyl functionalized Fe3O4 magnetic nanoparticles followed by spectrophotometric detection.  相似文献   

9.
Chenyu Li  Ligang Chen  Wei Li 《Mikrochimica acta》2013,180(11-12):1109-1116
We report on a method for the extraction of organophosphorus pesticides (OPPs) from water samples using mixed hemimicelles and magnetic titanium dioxide nanoparticles (Fe3O4@TiO2) modified by cetyltrimethylammonium. Fe3O4@TiO2 nanoparticles were synthesized by a hydrothermal process and then characterized by scanning electron microscopy and Fourier transform IR spectrometry. The effects of the quantity of surfactant, extraction time, desorption solvent, pH value, extraction volume and reuse of the sorbent were optimized with respect to the extraction of OPPs including chlorpyrifos, dimethoate, and trichlorfon. The extraction method was applied to analyze OPPs in environmental water using HPLC along with UV detection. The method has a wide linear range (100–15,000 ng L?1), good linearity (r?>?0.999), and low detection limits (26–30 ng L?1). The enrichment factor is ~1,000. The recoveries (at spiked levels of 100, 1,000 and 10,000 ng L?1) are in the range of 88.5–96.7 %, and the relative standard deviations range from 2.4 % to 8.7 %.
Figure
Schematic illustration of the preparation of CTAB coated Fe3O4@TiO2 and its application as SPE sorbent for enriching OPPs  相似文献   

10.
We report on the construction of a label-free electrochemical immunosensor for detecting the core antigen of the hepatitis C virus (HCV core antigen). A glassy carbon electrode (GCE) was modified with a nanocomposite made from gold nanoparticles, zirconia nanoparticles and chitosan, and prepared by in situ reduction. The zirconia nanoparticles were first dispersed in chitosan solution, and then AuNPs were prepared in situ on the ZrO2-chitosan composite. In parallel, a nanocomposite was synthesized from AuNPs, silica nanoparticles and chitosan, and conjugated to a secondary antibody. The properties of the resulting nanocomposites were investigated by UV-visible photometry and transmission electron microscopy, and the stepwise assembly process was characterized by means of cyclic voltammetry and electrochemical impedance spectroscopy. An sandwich type of immunosensor was developed which displays high sensitivity to the HCV core antigen in the concentration range between 2 and 512?ng?mL?1, with a detection limit of 0.17?ng?mL?1 (at S/N?=?3). This immunosensor provides an alternative approach towards the diagnosis of HCV.
Fig
A sandwich-type immunosensor was constructed for the detection of HCV core Ag. AuNPs/ZrO2-Chits nanocomposites were prepared by in situ reduction method. AuNPs/SiO2-Chits nanocomposite integrated with secondary antibody (Ab2) without labeled HRP. The immunosensor displayed high sensitivity to HCV core antigen with a detection limit of 0.17?ng?mL?1 (S/N?=?3).  相似文献   

11.
We have prepared and characterized Fe3O4 nanoparticles and their binary mixtures (IL-Fe3O4) with 1-hexyl-3-methylimidazolium bromide as ionic liquid for use in the adsorption of lysozyme (LYS), bovine serum albumin (BSA), and myoglobin (MYO). The optimum operational conditions for the adsorption of proteins (at 0.05–2.0 mg?mL?1) were 4.0 mg?mL?1 of nanoparticles and a contact time of 10 min. The maximum adsorption capacities are 455, 182 and 143 mg for LYS, BSA, and MYO per gram of adsorbent, respectively. The Langmuir model better fits the adsorption isotherms, with adsorption constants of 0.003, 0.015 and 0.008 L?mg?1, in order, for LYS, BSA, MYO. The applicability of two kinetic models including pseudo-first order and pseudo-second order model was estimated on the basis of comparative analysis of the corresponding rate parameters, equilibrium adsorption capacity and correlation coefficients. The adsorption processes are endothermic. The proteins can be desorbed from the nanoparticles by using NaCl solution at pH 9.5, and the nanoparticles thus can be recycled.
Figure
Nanoparticles of Fe3O4 as well as its binary mixtures with ionic liquids (IL-Fe3O4) were prepared and used for adsorption of lysozyme, bovine serum albumin and myoglobin. The mean size and the surface morphology of both nanoparticles were characterized by TEM, DLS, XRD, FTIR and TGA techniques. The applicability of two kinetic models including pseudo-first order and pseudo-second order model was estimated on the basis of comparative analysis of the corresponding rate parameters, equilibrium adsorption capacity and correlation coefficients  相似文献   

12.
We have modified a glassy carbon electrode (GCE) with a film of poly(3-thiophene boronic acid), gold nanoparticles and graphene, and an antibody (Ab) was immobilized on its surface through the covalent bond formed between the boronic acid group and the glycosyl groups of the Ab. Subgroup J of avian leukosis viruses (ALV-J) were electrochemically determined with the help of this electrode. There is a linear relationship between the electron transfer resistance (R et) and the concentration of ALV-J in the range from 527 to 3,162 TCID50?mL?1 (where TCID50 is the 50?% tissue culture infective dose). The detection limit is 210 TCID50?mL?1 (at an S/N of 3), and the correlation coefficient (R) is 0.9964. The electrochemical immunoassay showed good selectivity, stability and reproducibility.
Figure
Schematic illustration of the stepwise immunosensor fabrication process  相似文献   

13.
We report on an electrochemical sensor for the determination of methyl parathion. It is based on an electrode modified with multi-walled carbon nanotubes that were covered with gold nanoparticles (Au-NPs). The vertically aligned array of MWCNTs on a tantalum substrate was coated with Au-NPs by overhead magnetron sputtering deposition. Scanning and transmission electron microscopy and XRD were used to characterize the Au-NP-MWCNTs composite. Cyclic voltammetry and differential pulse voltammetry were employed to evaluate the suitability of the new electrode for the determination of methyl parathion. Under the optimal conditions, the current response of the electrode to methyl parathion is linear in the range from 0.50 to 16.0 mg mL-1, with a detection limit of 50 ??g mL-1 (signal/noise = 3), and the sensitivity is 4.5 times better than that of the plain MWCNTs electrode. We conclude that this method represents a simple, rapid, effective and sensitive approach for the detection of methyl parathion.
Figure
Gold nanoparticles were coated onto vertically aligned carbon nanotubes by over head magnetron sputtering deposition. The Au/MWCNTs electrode exhibits high performance and long term storage stability for eletroanalysis of methyl parathion, showing a linear dependence in methyl parathion concentration from 0.50 to 16.0 ??g·mL-1 and detection limit of 0.050 ??g·mL-1.  相似文献   

14.
We have prepared a glassy carbon electrode modified with poly-2,6-pyridinedicarboxylic acid and with magnetic Fe3O4 nanoparticles. This modification enhances the effective surface area and the electrocatalytic oxidation of nicotinamide adenine dinucleotide (NADH) in addition to providing positively charged groups for electrostatic assembly of the phosphate group of NADH. The modified electrode responds linearly to NADH in the range from 5?×?10?8 to 2.5?×?10?5?M and gives a lower detection limit of 1?×?10?8?M. It displays satisfactory selectivity and reproducibility. The sensor was applied to rapid screening of plant extracts for their antioxidant properties.
Figure
Poly-2,6-pyridinedicarboxylic acid (PDC) was fabricated by electropolymerizing 2,6-pyridinedicarboxylic acid with cyclic voltammetry (CV) on the glassy carbon electrode (GCE) surface. The magnetic Fe3O4 nanoparticles treated with aminopropyltriethoxysilane (APTS) modified on the PDC/GCE to form APTS-Fe3O4/PDC composite film. The APTS-Fe3O4/PDC film had enhanced the effective electrode surface area and provided positively charged groups for electrostatic assembly of phosphate group of NADH.  相似文献   

15.
Graphene-based magnetic nanoparticles (G-Fe3O4) were prepared and used as an effective adsorbent for the solid-phase extraction of trace quantities of cadmium from water and vegetable samples. The method avoids some of the time-consuming steps associated with traditional solid phase extraction. The excellent sorption property of the G-Fe3O4 system is attributed to π - π stacking interaction and hydrophobic interactions between graphene and the Cd-PAN complex. The effects of pH, the amount of G–Fe3O4, extraction time, type and volume of eluent, desorption time and interfering ions on the extraction efficiency were optimized. The preconcentration factor is 200. Cd(II) was then quantified by flame atomic absorption spectrometry with a detection limit of 0.32 ng mL?1. The relative standard deviation (at 50 ng mL?1; for n?=?10) is 2.45 %. The method has a linear analytical range from 1.1 to 150 ng mL?1, and the recoveries in case of real samples are in the range between 93.1 % and 102.3 %.
Figure
General procedure for magnetic preconcentration of cadmium ions from aqueous solution using graphene-based magnetic nanoparticles  相似文献   

16.
We report on a novel electrochemiluminescent (ECL) immunoassay for the ultrasensitive determination of morphine by making use of a gold electrode which was modified with a nanocomposite film containing self-assembled polyamidoamine (PAMAM) CdS quantum dots and electrodeposited gold nanoparticles (Au-NPs). The highly uniform and well-dispersed quantum dots were capped with PAMAM dendrimers. Due to the synergistic effect of the modified quantum dots and the electrodeposited Au-NPs, the ECL response is dramatically enhanced. Under optimal experimental conditions, the immunoreaction between morphine and anti-morphine antibody resulted in a decrease of the ECL signal because of steric hindrance. The calibration plot is linear in the morphine concentration range from 0.2 to 180 ng?mL?1, with a detection limit as low as 67 pg?mL?1. The sensor was successfully applied to the determination of morphine in blood plasma. This kind of assay is expected to pave new avenues in label-free drug assays.
Figure
?  相似文献   

17.
We have investigated the adsorption of herring sperm DNA on Fe3O4 magnetic nanoparticles (NPs) before and after modification with the ionic liquid 1-hexyl-3-methylimidazolium bromide. Experiments were performed in a batch mode, and the effects of DNA concentration, pH of the sample solution, ionic strength, temperature, and contact time between reagents were optimized. An evaluation of the adsorption isotherm revealed that the Langmuir model better fits the equilibrium data than the Freundlich model. The maximum adsorption capacities of the unmodified and modified NPs, respectively, were found to be 11.8 and 19.8 mg DNA per gram of adsorbent. The adsorption of DNA onto the modified NPs was endothermic, while it was exothermic in the case of the unmodified NPs. The DNA can be desorbed from the modified surfaces of the NPs by using EDTA as the eluent. The NPs were able to adsorb about 90?±?1.5 % of DNA after being recycled for three times. The method is simple, fast, robust, and does not require organic solvents or sophisticated equipment.
Figure
Fe3O4 nanoparticles as well as 1-hexyl-3-methylimidazolium bromidecoated Fe3O4 nanoparticles were prepared and used for adsorption of DNA. The mean size and the surface morphology of both nanoparticles were characterized by TEM, DLS, XRD, FTIR and TGA techniques. The correlation coefficient of the Langmuir model suggests a better fit for the experimental equilibrium adsorption data.  相似文献   

18.
We report on a new enzyme-free electrochemical immunoassay for the sensitive detection of the p53 protein (p53; a model analyte) by using a screen-printed carbon electrode modified with monoclonal mouse anti-human p53 antibody tagged with gold nanoparticles. First, nanogold microspheres doped with Prussian Blue were synthesized by a reverse micelle method. The resulting microspheres were used to label polyclonal anti-p53 antibody which then was applied in a sandwich immunoassay in pH 6.5 buffer solution using the Prussian Blue in the particles as the redox-active reporter. The electrochemical signal of the immunosensor is shown to increase with the concentration of the analyte (p53 protein) in the range from 0.5 to 80 U mL?1, with a detection limit of 0.1 U mL?1. No non-specific adsorption was observed. Coefficients of variation for intra-assay and inter-assay were below 8.5 % and 11.5 %, respectively. In addition, the method was applied to the analysis of 15 human serum samples, and a good relationship was found between the new immunoassay and the referenced electro-chemiluminescence method.
Figure
?  相似文献   

19.
We report on a carbon nanotube (CNT) fiber microelectrode coated with palladium nanoparticles (PdNPs) and enabling electrochemical sensing of hydrogen peroxide (H2O2). The synergistic effects of the CNT fibers (good mechanical strength and large surface area) and of the PdNPs (high electrocatalytic activity) result in a microelectrode for H2O2 that exhibits a 2-s response time, a detection limit as low as 2 μM, a sensitivity of 2.75 A cm?2 M?1, and a linear response range from 2 μM to 1.3 mM (R?=?0.9994). The sensor is also selective and not interfered by potentially competing species in biological fluids, thus representing an inexpensive but highly sensitive and selective microsensor for H2O2.
Figure
Images ofthe palladium nanoparticle-coated carbon nanotube (PdNP/CNT) fiber microelectrode (left) and its amperometric response to hydrogen peroxide (H2O2) with different concentrations (right)  相似文献   

20.
An ion imprinted polymer coated onto magnetite (Fe3O4) nanoparticles is shown to be a useful magnetic sorbent for the fairly selective preconcentration of vanadium. The sorbent was prepared by radical copolymerization of 3-(triethoxysilyl)propyl methacrylate (the monomer), ethylene glycol dimethacrylate (the cross-linker), and the vanadium(IV) complex of 1-(2-pyridylazo-2-naphthol) in the presence of magnetite nanoparticles. The material was characterized by IR spectroscopy, scanning electron microscopy, and thermal analysis. The vanadium(IV) ions were removed from the imprint by a solution containing thiourea and HCl, and the eluent was submitted to AAS. The analytical efficiency and relative standard deviation are 99.4 and ±2.3 %, respectively, under optimum conditions, and the limit of detection is 20 ng mL?1. The method was successfully applied to the preconcentration and determination of vanadium(IV) ions in crude oil. Figure
An ion imprinted polymer is coated on to magnetite nanoparticles as a useful magnetic sorbent for the fairly selective preconcentration of vanadium which can be used for vanadium determination in crude oil.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号