1.
A novel mercaptotetrazole‐silica hybrid monolithic column was prepared for capillary liquid chromatography, in which the thiol‐end mercaptotetrazole was mixed with hydrolyzed γ‐methacryloxypropyltrimethoxysilane and tetramethyloxysilane for the co‐polycondensation and thiol‐ene click reaction in a one‐pot process. The effects of the molar ratio of silanes, the amount of mercaptotetrazole, and the volume of porogen on the morphology, permeability and pore properties of the as‐prepared mercaptotetrazole‐silica hybrid monoliths were investigated in detail. A series of test compounds including alkylbenzenes, amides and anilines were employed for evaluating the retention behaviors of the mercaptotetrazole‐silica hybrid monolithic columns. The results demonstrated that the mercaptotetrazole‐silica hybrid monoliths exhibited hydrophobic, hydrophilic as well as ion‐exchange interaction. The run‐to‐run, column‐to‐column and batch‐to‐batch reproducibilities of the mercaptotetrazole‐silica hybrid monoliths were satisfactory with the relative standard deviations less than 1.4 (= 5), 3.9 (= 3) and 4.0% (= 5), respectively. In addition, the mercaptotetrazole‐silica hybrid monolith was further applied to the separation of sulfonamides, nucleobases and protein tryptic digests. These successful applications confirmed the promising potential of the mercaptotetrazole‐silica hybrid monolith in the separation of complex samples.  相似文献   

2.
This article describes the synthesis, chromatographic characterization, and performance evaluation of analytical (100 x 4.6 mm id) and semipreparative (100 x 10 mm id) monolithic silica columns with mixed-mode RP/weak anion-exchange (RP/WAX) surface modification. The monolithic RP/WAX columns were obtained by immobilization of N-(10-undecenoyl)-3-aminoquinuclidine onto thiol-modified monolithic silica columns (Chromolith) by a radical addition reaction. Their chromatographic characterization by Engelhardt and Tanaka tests revealed slightly lower hydrophobic selectivities than C-8 phases, as well as higher polarity and also improved shape selectivity than RP-18e silica rods. The surface modification enabled separation by both RP and anion-exchange chromatography principles, and thus showed complementary selectivities to the RP-18e monoliths. The mixed-mode monoliths have been tested for the separation of peptides and turned out to be particularly useful for hydrophilic acidic peptides, which are usually insufficiently retained on RP-18e monolithic columns. Compared to a corresponding particulate RP/WAX column (5 microm, 10 nm pore diameter), the analytical RP/WAX monolith caused lower system pressure drops and showed, as expected, higher efficiency (e.g. by a factor of about 2.5 lower C-term for a tetrapeptide). The upscaling from the analytical to semipreparative column dimension was also successful.  相似文献   

3.
Reproducible fabrication of the hierarchically porous monolithic silica in a large volume exceeding 1000 mL has been established. By the hydrothermal enlargement of the fully accessible small pores to exceed 50 nm in diameter, the capillary force emerged on solvent evaporation was dramatically reduced, which allowed the preparation of crack‐free monoliths with evaporative solvent removal under an ambient pressure. The local temperature inhomogeneity within a reaction vessel in a large volume was precisely controlled to cancel the heat evolved by the hydrolysis reaction of tetramethoxysilane and that consumed to melt ice cubes dispersed in the solution, resulting in large monolithic silica pieces with improved structural homogeneity. Homogeneity of the pore structure was confirmed, both on macro‐ and mesoscales, using SEM, mercury intrusion, and nitrogen adsorption/desorption measurements. Furthermore, the deviations in chromatographic performance were examined by evaluating multiple smaller monolithic columns prepared from the monolithic silica pieces cut from different parts of a large monolith. All the daughter columns thus prepared exhibited comparable performances to each other to prove the overall homogeneity of the mother monolith. Preliminary results on high‐speed separation of peptides and proteins by the octadecylsilylated silica monolith of the above production have also been demonstrated.  相似文献   

4.
Various recent wide-pore reversed-phase stationary phases were studied for the analysis of intact monoclonal antibodies (mAbs) of 150 kDa and their fragments possessing sizes between 25 and 50 kDa. Different types of column technology were evaluated, namely, a prototype silica-based inorganic monolith containing mesopores of ~250 Å and macropores of ~?1.1 μm, a column packed with 3.6 μm wide-pore core-shell particles possessing a wide pore size distribution with an average around 200 Å and a column packed with fully porous 1.7 μm particles having pore size of ~300 Å. The performance of these wide-pore materials was compared with that of a poly(styrene–divinyl benzene) organic monolithic column, with a macropore size of approximately 1 μm but without mesopores (stagnant pores). A systematic investigation was carried out using model IgG1 and IgG2 mAbs, namely rituximab, panitumumab, and bevacizumab. Firstly, the recoveries of intact and reduced mAbs were compared on the two monolithic phases, and it appeared that adsorption was less pronounced on the organic monolith, probably due to the difference in chemistry (C18 versus phenyl) and the absence of mesopores (stagnant zones). Secondly, the kinetic performance was investigated in gradient elution mode for all columns. For this purpose, peak capacities per meter as well as peak capacities per time unit and per pressure unit (PPT) were calculated at various flow rates, to compare performance of columns with different dimensions. In terms of peak capacity per meter, the core-shell 3.6 μm and fully porous 1.7 μm columns outperformed the two monolithic phases, at a temperature of 60 °C. However, when considering the PPT values, the core-shell 3.6 μm column remained the best phase while the prototype silica-based monoliths became very interesting, mostly due to a very high permeability compared with the organic monolith. Therefore, these core-shell and silica-based monolith provided the fastest achievable separation. Finally, at the maximal working temperature of each column, the core-shell 3.6 μm column was far better than the other one, because it is the only one stable up to 90 °C. Lastly, the loading capacity was also measured on these four different phases. It appeared that the organic monolith was the less interesting and rapidly overloaded, due to the absence of mesopores. On the other hand, the loading capacity of prototype silica-based monolith was indeed reasonable.  相似文献   

5.
Two polar ligands, namely 3-hydroxypropionitrile and 1H-imidazole-4,5-dicarbonitrile (IDCN) were covalently attached to epoxy-activated silica-based monolithic capillary columns via an epoxide ring-opening reaction to yield CN-OH-Monolith and 2CN-OH-Monolith, respectively. The silica monolith was prepared by a sol-gel process, and the resulting "rod-like" stationary phase was subjected to pore tailoring with an alkaline solution to convert small pore domains to mesopore domains, thus yielding a monolith with bimodal pore structure consisting of flow through pores (i.e., flow channels for mobile-phase flow) and mesopores that provide most of the adsorption capacity of the monolith toward the separated solutes. The two polar monoliths, CN-OH-Monolith and 2CN-OH-Monolith, were evaluated in normal-phase CEC with organic-rich mobile phases less polar than the stationary phase. The 2CN-OH-Monolith bearing more polar functions than the CN-OH-Monolith exhibited more retention and improved selectivity toward model polar solutes.  相似文献   

6.
An affinity monolith based on silica and containing immobilized alpha(1)-acid glycoprotein (AGP) was developed and evaluated in terms of its binding, efficiency and selectivity in chiral separations. The results were compared with data obtained for the same protein when used as a chiral stationary phase with HPLC-grade silica particles or monoliths based on a copolymer of glycidyl methacrylate (GMA) and ethylene dimethacrylate (EDMA). The surface coverage of AGP in the silica monolith was 18% higher than that obtained with silica particles and 61% higher than that measured for a GMA/EDMA monolith. The higher surface area of the silica monolith gave materials that contained 1.5- to 3.6-times more immobilized protein per unit volume when compared to silica particles or a GMA/EDMA monolith. The retention, efficiency and resolving power of the AGP silica monolith were evaluated by injecting two chiral analytes onto this column (i.e., R/S-warfarin and R/S-propranolol). In each case, the AGP silica monolith gave higher retention plus better resolution and efficiency than AGP columns containing silica particles or a GMA/EDMA monolith. The AGP silica monolith also gave lower back pressures and separation impedances than these other materials. It was concluded that silica monoliths can be valuable alternatives to silica particles or GMA/EDMA monoliths when used with AGP as a chiral stationary phase.  相似文献   

7.
Silica monolithic columns suitable for implementation on microchips have been evaluated by ion-exchange capillary electrochromatography. Two different silica monoliths were created from the alkyl silane, tetramethyl orthosilicate (TMOS), by introducing a water-soluble organic polymer, poly(ethylene oxide) (PEO), with varying molecular weights into the prehydrolyzed sol. Silica monoliths created using 10 kDa PEO were found to have a much more closed gel structure with a smaller percentage of pores in the microm size range than gels created using 100 kDa PEO. Additionally, the size of the mesopores in the 100 kDa PEO monolith was 5 nm, while those in the 10 kDa PEO gel were only 3 nm. This resulted in a strong dependence of the electroosmotic flow (EOF) on the ionic strength of the background electrolyte, with substantial pore flow through the nm size pores observed in the 10 kDa PEO gel. The chromatographic performance of the monolithic columns was evaluated by ion-exchange electrochromatography, with ion-exchange sites introduced via dynamic coating with the cationic polymer, poly(diallyldimethylammonium chloride) (PDDAC). Separating a mixture of inorganic anions, the 10 kDa PEO monolithic columns showed a higher effective capacity than the 100 kDa PEO column.  相似文献   

8.
Commercially available silica‐based monolithic columns Chromolith RP‐8e, Chromolith RP‐18, and Chromolith HR RP‐18, and polymer‐based monolithic columns ProSwift RP‐1S, ProSwift RP‐2H, and ProSwift RP‐3U varying in pore size and bonded phase have been tested for the fast separation of selected sets of analytes. These mixtures of analytes included small molecules (uracil, caffeine, 1‐phenylethanol, butyl paraben, and anthracene), acylated insulins, and intact proteins (ribonuclease A, cytochrome C, transferrin, apomyoglobin, and thyroglobulin), and covered wide range of chemistries and sizes. Small molecules were well separated with a height equivalent to theoretical plate of 11–26 μm using silica‐based monolithic columns, while organic polymer‐based monoliths excelled in the fast sub 1 min baseline separations of large molecules. A peak capacity of 37 was found for separation of acylated insulins on Chromolith columns using a 3 min gradient at a flow rate of 3 ml/min. Poor recovery of proteins from Chromolith columns and significant peak tailing of small molecules using ProSwift columns were the major obstacles in using monolithic columns in those applications.  相似文献   

9.
《先进技术聚合物》2018,29(7):2110-2120
A reactive monolith based on the polymerization of 3‐chloro‐2‐hydroxypropyl methacrylate, (HPMA‐Cl), with a crosslinking agent, ethylene glycol dimethacrylate (EDMA), was synthesized and post‐functionalized with a macromolecular ligand polyethyleneimine. Monolithic columns with controlled permeability and pore structure were prepared by free radical polymerization in the presence of a binary porogenic mixture of isopropanol and decanol. The presence of chloropropyl functionality in the pristine monolith allowed the synthesis of a post‐fuctionalized monolith carrying cationic groups that was used to control the magnitude of electroosmotic flow (EOF) in electrochromatographic separation. In the synthesis of pristine monoliths, the feed concentration of functional monomer (ie, HPMA‐Cl) was changed between 30 and 60 v/v % for obtaining cationic monoliths providing satisfactory electrochromatographic separation. The best electrochromatographic performance was obtained with the polyethyleneimine functionalized monolith prepared by using the pristine monolith obtained by 60% (v/v) monomer concentration. This monolith was used in reversed phase and hydrophilic interaction capillary electrochromatography modes for the separation of alkylbenzenes, polycyclic aromatic hydrocarbons, phenols, and nucleosides, using mobile phases with low acetonitrile (ACN) contents ranging between 20% and 35% (v/v). This ACN range was remarkably lower than the content of ACN used on the hydrophilic polymethacrylate‐based monoliths reported previously (ie, >90%). The plate heights up to 5.3 μm were obtained for the separation of nucleosides with the environmental friendly mobile phases whose ACN contents were also remarkably lower than that of similar polymethacrylate‐based monoliths.  相似文献   

10.
Porous hybrid organo‐silica monoliths have been prepared inside pretreated 100 μm id UV transparent fused‐silica capillaries using simultaneous sol‐gel transition and polymerization of 3‐(methacryloyloxy)propyl trimethoxysilane in the presence of toluene as a porogen. The sol‐gel reaction was catalyzed by hydrochloric acid while various photoinitiators including azobisisobutyronitrile, 2,2‐dimethoxy‐2‐phenylacetophenone, and Irgacure 819 were used for the photopolymerization carried out under irradiation with UV light at a wavelength of 254 or 365 nm. The chromatographic performance of photopolymerized monolithic columns in RP liquid chromatographic mode was assessed with respect to the following metrics: column efficiency, methylene and steric selectivity, effect of silanol groups, van Deemter plot, permeability, and pore size distribution. Columns with an efficiency of up to 77 000 plates/m for benzene has been achieved at a flow velocity of 0.47 mm/s. The performance of photopolymerized hybrid monolithic column was compared to the performance of columns prepared via thermally initiated polymerization.  相似文献   

11.
Metal‐organic frameworks consisting of amino‐modified MIL‐101(M: Cr, Al, and Fe) crystals have been synthesized and subsequently incorporated to glycidyl methacrylate monoliths to develop novel stationary phases for nano‐liquid chromatography. Two incorporation approaches of these materials in monoliths were explored. The metal‐organic framework materials were firstly attached to the pore surface through reaction of epoxy groups present in the parent glycidyl methacrylate‐based monolith. Alternatively, NH2‐MIL‐101(M) were admixed in the polymerization mixture. Using short time UV‐initiated polymerization, monolithic beds with homogenously dispersed metal‐organic frameworks were obtained. The chromatographic performance of embedded UV‐initiated composites was demonstrated with separations of polycyclic aromatic hydrocarbons and non‐steroidal anti‐inflammatory drugs as test solutes. In particular, the incorporation of the NH2‐MIL‐101(Al) into the organic polymer monoliths led to an increase in the retention of all the analytes compared to the parent monolith. The hybrid monolithic columns also exhibited satisfactory run‐to‐run and column‐to‐column reproducibility.  相似文献   

12.
合成条件对硅胶整体柱中孔结构的影响   总被引:1,自引:0,他引:1  
硅胶整体柱是目前备受关注的液相色谱固定相。本文考察了合成条件对硅胶整体柱中孔结构的影响,包括反应体系的pH值、聚乙二醇(PEG)含量及分子量。实验表明,反应体系的pH值能有效地调控硅胶整体柱的中孔孔径及孔结构,当pH值为2或5时,整体柱中孔孔径较小;而当pH值为3或9时,孔径较大,孔结构趋于圆筒状。整体柱的中孔平均孔径随着PEG含量和分子量的增加而增加,其孔径分布也逐渐变宽。  相似文献   

13.
The surface modification of mesoporous silica monoliths through thiol–ene chemistry is reported. First, mesoporous silica monoliths with vinyl, allyl, and thiol groups were synthesized through a sol–gel hydrolysis–polycondensation reaction from tetramethyl orthosilicate (TMOS) and vinyltriethoxysilane, allyltriethoxysilane, and (3‐mercaptopropyl)trimethoxysilane, respectively. By variation of the molar ratio of the comonomers TMOS and functional silane, mesoporous silica objects containing different amounts of vinyl, allyl, and thiol groups were obtained. These intermediates can subsequently be derivatized through radical photoaddition reactions either with a thiol or an olefin, depending on the initial pore wall functionality, to yield silica monoliths with different pore‐wall chemistries. Nitrogen sorption, small‐angle X‐ray scattering, solid‐state NMR spectroscopy, elemental analysis, thermogravimetric analysis, and redox titration demonstrate that the synthetic pathway influences the morphology and pore characteristics of the resulting monoliths and also plays a significant role in the efficiency of functionalization. Moreover, the different reactivity of the vinyl and allyl groups on the pore wall affects the addition reaction, and hence, the degree of the pore‐wall functionalization. This report demonstrates that thiol–ene photoaddition reactions are a versatile platform for the generation of a large variety of organically modified silica monoliths with different pore surfaces.  相似文献   

14.
Poly(styrene‐co‐divinylbenzene) monolithic stationary phases with two different domain sizes were synthesized by a thermally initiated free‐radical copolymerization in capillary columns. The morphology was investigated at the meso‐ and macroscopic level using complementary physical characterization techniques aiming at better understanding the effect of column structure on separation performance. Varying the porogenic solvent ratio yielded materials with a mode pore size of 200 nm and 1.5 μm, respectively. Subsequently, nano‐liquid chromatography experiments were performed on 200 μm id × 200 mm columns using unretained markers, linking structure inhomogeneity to eddy dispersion. Although small‐domain‐size monoliths feature a relatively narrow macropore‐size distribution, their homogeneity is compromised by the presence of a small number of large macropores, which induces a significant eddy‐dispersion contribution to band broadening. The small‐domain size monolith also has a relatively steep mass‐transfer term, compared to a monolith containing larger globules and macropores. Structural inhomogeneity was also studied at the mesoscopic level using gas‐adsorption techniques combined with the non‐local‐density‐function‐theory. This model allows to accurately determine the mesopore properties in the dry state. The styrene‐based monolith with small domain size has a distinctive trimodal mesopore distribution with pores of 5, 15, and 25 nm, whereas the monolith with larger feature sizes only contains mesopores around 5 nm in size.  相似文献   

15.
A new thermally switchable molecularly imprinted monolith for the selective capture and release of proteins has been designed. First, a generic poly(glycidyl methacrylate‐co‐ethylene dimethacrylate) monolith reacted with ethylenediamine followed by functionalization with 2‐bromoisobutyryl bromide to introduce the initiator for atom transfer radical polymerization. Subsequently, a protein‐imprinted poly(N‐isopropylacrylamide) layer was grafted onto the surface of the monolithic matrix by atom transfer radical polymerization. Scanning electron microscopy and energy‐dispersive X‐ray spectroscopy of the cross‐sections of imprinted monoliths confirmed the formation of dense poly(N‐isopropylacrylamide) brushes on the pore surface. The imprinted monolith exhibited high specificity and selectivity toward its template protein myoglobin over competing proteins and a remarkably large maximum adsorption capacity of 1641 mg/g. Moreover, this “smart” imprinted monolith featured thermally responsive characteristics that enabled selective capture and easy release of proteins triggered only by change in temperature with water as the mobile phase and avoided use of stronger organic solvents or change in ionic strength and pH.  相似文献   

16.
The aim of this work is to join the advantages of two different kinds of stationary phases: monolithic columns and zirconia-based supports. On the one hand, silica monolithic columns allow a higher efficiency with a lower back-pressure than traditional packed columns. On the other hand, chromatographic stationary phases based on zirconia have a higher thermal and chemical stability and specific surface properties. Combining these advantages, a zirconia monolith with a macroporous framework could be a real improvement in separation sciences. Two main strategies can be used in order to obtain a zirconia surface on a monolithic skeleton: coating or direct synthesis. The coverage by a zirconia layer of the surface of a silica-based monolith can be performed using the chemical properties of the silanol surface groups. We realized this coverage using zirconium alkoxide and we further grafted n-dodecyl groups using phosphate derivatives. Any loss of efficiency was observed and fast separations have been achieved. The main advance reported in this paper is related to the preparation of zirconia monoliths by a sol-gel process starting from zirconium alkoxide. The synthesis parameters (hydrolysis ratio, porogen type, precursor concentration, drying step, etc.) were defined in order to produce a macroporous zirconia monoliths usable in separation techniques. We produced various homogeneous structures: zirconia rod 2 cm long with a diameter of 2.3 mm, and zirconia monolith inside fused silica capillaries with a 75 microm I.D. These monoliths have a skeleton size of 2 microm and have an average through pore size of 6 microm. Several separations have been reported.  相似文献   

17.
This study investigates the synthesis and chromatographic behaviour of an analytical size cyanopropyl “cyano” bonded silica monolith. Surface modification was undertaken by treating a neat silica monolith with chloro(3-cyanopropyl)dimethyl silane in dry heptane over a two day period. The resulting monolith showed stability over the duration of the testing program that involved flushing the column with more than 2000 column volumes of mobile phase. Efficiency measurements before and after sylation verified that the integrity of the silica monolith itself was not affected by the modification process, the highest number of theoretical plates (N/m) using anisole was 81,650. A brief selectivity test was then undertaken to assess methylene selectivity and phenyl selectivity. Elemental analysis was used to determine the homogeneity of the carbon load throughout the monolithic bed, and was compared to two commercial C18 and one ‘self’ modified C18 silica monoliths. The development of the in situ modification is also discussed.  相似文献   

18.
Derivatized β‐cyclodextrin (β‐CD) functionalized monolithic columns were prepared by a “one‐step” strategy using click chemistry. First, the intended derivatized β‐CD monomers were synthesized by a click reaction between propargyl methacrylate and mono‐6‐azido‐β‐CD and then sulfonation or methylation was carried out. Finally, monolithic columns were prepared through a one‐step in situ copolymerization of the derivatized β‐CD monomer and ethylene glycol dimethacrylate. The sulfated β‐CD‐based monolith was successfully applied to the hydrophilic interaction liquid chromatography separation of nucleosides and small peptides, while the methylated β‐CD‐functionalized monolith was useful for the separation of nonpolar compounds and drug enantiomers in capillary reversed‐phase liquid chromatography. The structures of the monomers were characterized by Fourier transform infrared spectroscopy and mass spectrometry. The physicochemical properties and column performance of monoliths were evaluated by scanning electron microscopy and micro high performance liquid chromatography. This strategy has considerable prospects for the preparation of other derivatized CD‐functionalized methacrylate monoliths.  相似文献   

19.
The search for a method to fabricate monolithic inorganic columns has attracted significant recent attention due to their unique ability in separation applications of various biomolecules. Silica and polymer based monolithic columns have been prepared, but titania and other metal oxide monoliths have been elusive, primarily due to their fragility. This article describes a new approach for preparing nanostructured titania based columns, which offer better performance over conventional particle packed columns for separating a wide variety of biomolecules including phosphopeptides. TiO2 monolithic aerogels were synthesized in separation columns using in situ sol‐gel reactions in supercritical carbon dioxide (scCO2) followed by calcination, and compared to those prepared in heptanes. The characterization results show that scCO2 is a better solvent for the sol‐gel reactions, providing lower shrinkage with the anatase TiO2 monolith composed of nanofibers with very high surface areas. The monolithic columns show the ability to isolate phosphopeptides with little flow resistance compared to conventional titania particle based microcolumns.  相似文献   

20.
The concept of biocompatibility with reference to chromatographic stationary phases for separation of biomolecules (including proteins and peptides) is introduced. Biocompatible is a characteristic that indicates resistance to nonspecific adsorption of biomolecules and preservation of their structures and biochemical functions. Two types of biocompatible polymeric monoliths [i. e., polyacrylamide‐ and poly(meth)acrylate‐based monoliths] used for protein and peptide separations are reviewed in detail, with emphasis on size exclusion, ion exchange, and hydrophobic interaction chromatographic modes. Biocompatible monoliths for enzyme reactors are also included. The two main synthetic approaches to produce biocompatible monoliths are summarized, i. e., surface modification of a monolith that is not inherently biocompatible and direct copolymerization of hydrophilic monomers to form a biocompatible monolith directly. Integration of polyethylene glycol into the poly(meth)acrylate monolith network is becoming popular for reduction of non‐specific protein interactions.  相似文献   