首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 781 毫秒
1.
A second‐derivative spectrophotometric method based on zero‐crossing over technique is developed in simultaneous determination of copper(II) and nickel(II) ions. Methylthymol blue (MTB) as a chromogenic reagent and cetyltrimethylammonium bromide as a surfactant were used, and measurements were carried out in buffered solution at pH 6 and at a temperature of 25 °C. The amplitude of derivative spectra was measured at wavelengths of 631.9 and 587.7 nm for the simultaneous determination of Ni2+ and Cu2+, respectively. Linearity was obtained in the range of 0.5–5.0 μg mL?1 for both ions in the presence of 0.0–5.0 μg mL?1 of the other ion as an interfering ion. IUPAC detection limits for Cu2+ and Ni2+ ions were obtained at 0.48 and 0.43 μg mL?1, respectively. The proposed procedure has been applied successfully for the simultaneous determination of copper and nickel in synthetic binary mixtures and real samples.  相似文献   

2.
A novel generic reverse phase high performance liquid chromatography (RP‐HPLC) method is developed and validated for simultaneous determination of seven pharmaceutically active ingredients, namely, acetaminophen, dextromethorphan, doxylamine, phenylephrine, guaifenesin, caffeine and aspirin. All seven ingredients were quantified in soft gel, syrup and tablet formulations of the over‐the‐counter US‐marketed products, as per the guidelines of the International Conference on Harmonization. The separation was achieved in a 16 min run time on an Agilent Zorbax Phenyl column using a gradient method with two mobile phases. Mobile phase A was 0.15% trifluoro acetic acid in purified water and while mobile phase B was a mixture of acetonitrile and methanol (750:250 v/v) with 0.02% trifluoro acetic acid. The flow rate was 1.0 mL min?1 and injection volume was 10 μL. Detection was performed at 280 nm using a photodiode array detector. As part of the method validation, specificity, linearity, precision and recovery parameters were verified. The concentration and area relationships were linear (R2 > 0.999), over the concentration ranges 20–120 μg mL?1 for acetaminophen, 75–450 μg mL?1 for dextromethorphan, 31.25–187.5 μg mL?1 for doxylamine, 25–150 μg mL?1 for phenylephrine, 25–150 μg mL?1 for aspirin, 6.5–39 μg mL?1 for caffeine and 12–72 μg mL?1 for guaifenesin. The relative standard deviations for precision and intermediate precision were <1.5%. The proposed RP‐HPLC generic method is applicable for routine analysis of cold and cough over‐the‐counter products.  相似文献   

3.
Simultaneous determination of hydrazine (HZ) and thiosemicarbazide (TSC) by partial least squares (PLS) and principle component regression (PCR) was carried out based on kinetic data of novel potentiometry. The rate of chloride ion production in reaction of HZ and TSC with N‐chlorosuccinimide (NCS) was monitored by a chloride ion‐selective electrode. The experimental dada shows not only the good ability of ion‐selective electrodes (ISEs) as detectors for the direct determination of chloride ions but also for simultaneous kinetic‐potentiometric analysis using chemometrics methods. The methods are based on the difference observed in the production rate of chloride ions. The results show that simultaneous determination of HZ and TSC can be performed in their concentration ranges of 0.7‐20.0 and 0.5‐20.0 μg mL?1, respectively. The total relative standard error for applying PLS and PCR methods to 9 synthetic samples in the concentration ranges of 0.8‐10 μg mL?1 of TSC and 1.0‐12.0 μg mL?1 of HZ was 4.62 and 4.98, respectively. The effects of certain foreign ions upon the reaction rate were determined for the assessment of the selectivity of the method. Both methods (PLS and PCR) were validated using a set of synthetic sample mixtures and then applied for simultaneous determination of HZ and TSC in water samples.  相似文献   

4.
A very simple spectrophotometric method for simultaneous determination of aluminum(III) and iron(III) based on formation of their complexes with pyrocatechol violet (PCV) in micellar media, using the H‐point standard addition method (HPSAM), is described. In micellar media, the metal complexes of Al‐PCV and Fe‐PCV are formed very fast. Formation of both of the complexes was complete within 5 min at pH 8.5. The linear ranges for aluminum and iron were 0.05‐2.50 and 0.10‐4.00 μg mL?1, respectively. The relative standard deviation (R.S.D.) for the simultaneous determination 0.40 μg mL?1 of Al(III) and 0.20 μg mL?1 of Fe(III) were 3.24% and 4.22%, respectively. Interference effects of common anions and cations were studied. The method was applied to simultaneous determination of Al(III) and Fe(III) in standard reference material and alloy samples.  相似文献   

5.
《Electroanalysis》2017,29(7):1691-1699
The simultaneous voltammetric determination of melatonin (MT) and pyridoxine (PY) has been carried out at a cathodically pretreated boron‐doped diamond electrode. By using cyclic voltammetry, a separation of the oxidation peak potentials of both compounds present in mixture was about 0.47 V in Britton‐Robinson buffer, pH 2. The results obtained by square‐wave voltammetry allowed a method to be developed for determination of MT and PY simultaneously in the ranges 1–100 μg mL−1 (4.3×10−6–4.3×10−4 mol L−1) and 10–175 μg mL−1 (4.9×10−5–8.5×10−4 mol L−1), with detection limits of 0.14 μg mL−1 (6.0×10−7 mol L−1) and 1.35 μg mL−1 (6.6×10−6 mol L−1), respectively. The proposed method was successfully to the dietary supplements samples containing these compounds for health‐caring purposes.  相似文献   

6.
A new validated potentiometric method is described for batch and continuous quality control monitoring of the drug oseltamivir phosphate (Taminil) (OST). The method involves the development of a potentiometric sensor responsive to the drug based on the use of the ion‐association complex of (OST+) cation with phosphomolybdate anion (PMA?) as an electroactive material in a poly(vinyl chloride) matrix membrane plasticized with o‐nitrophenyloctyl ether (o‐NPOE). Optimization of the performance characteristics of the sensor is described. A membrane incorporating the OST‐PMA‐NPOE complex in a tubular flow through detector is used in a two channel flow injection set up for continuous monitoring of the drug at a frequency of ~30 samples h?1. The sensor shows fast near‐Nernstian response for OST over the concentration range 5.2×10?5–0.8×10?2 M (21.34 µg mL?1–3.23 mg mL?1) with a detection limit of 9.1×10?6 M (3.73 µg mL?1) over the pH range 4.6–6.1. The sensor displays good selectivity for OST drug over some basic drugs, inorganic cations, excipients and diluents commonly used in the drug formulations. Validation of the assay method is tested by measuring the lower detection limit, range, linearity, bias, trueness, accuracy, precision, and between‐day‐variability, within day reproducibility, selectivity and ruggedness (robustness). The results reveal good potentiometric performance of the proposed sensor for determination of OST in pharmaceutical capsules and in biological fluid matrices as well as for testing the dissolution profile of the drug and drug homogeneity.  相似文献   

7.
A simple, sensitive, and rapid microextraction method, namely, ultrasound‐assisted surfactant‐enhanced emulsification microextraction based on the solidification of floating organic droplet method coupled with high‐performance liquid chromatography was developed for the simultaneous preconcentration and determination of nitrazepam and midazolam. The significant parameters affecting the extraction efficiency were considered using Plackett–Burman design as a screening method. To obtain the optimum conditions with consideration of the selected significant variables, a Box–Behnken design was used. The microextraction procedure was performed using 29.1 μL of 1‐undecanol, 1.36% (w/v) of NaCl, 10.0 μL of sodium dodecyl sulfate (25.0 μg mL?1), and 1.0 μL of Tween80 (25.0 μg mL?1) as an emulsifier in an extraction time of 20.0 min at pH 7.88. In order to investigate the validation of the developed method, some validation parameters including the linear dynamic range, repeatability, limit of detection, and recoveries were studied under the optimum conditions. The detection limits of the method were 0.017 and 0.086 ng mL?1 for nitrazepam and midazolam, respectively. The extraction recovery percentages for the drugs studied were above 91.0 with acceptable relative standard deviation. The proposed methodology was successfully applied for the determination of these drugs in a number of human serum samples.  相似文献   

8.
A validated spectrophotometric method has been developed for the determination of uranyl ion in soil samples. The method is based on the complexation reaction between uranyl ion and rifampicin in methanol‐water medium at room temperature. The method is followed spectrophotometrically by measuring the absorbance at 375 nm. Under the optimized experimental conditions, Beer's law is obeyed in the concentration range of 1.35–20.25 μg mL‐1 with apparent molar absorptivity and Sandell's sensitivity of 8.0 × 103 L mol‐1cm‐1 and 0.042 μg/cm2/0.001 absorbance unit, respectively. The interference of a large number of anions and cations has been investigated and the optimized conditions developed have been utilized for the determination of uranium(VI) in soil samples. The three sigma detection limit (n = 9) for uranyl ion was found to be 0.20 μg mL‐1. The proposed method was successfully applied to the determination of uranyl ion in soil samples.  相似文献   

9.
A sequential online extraction, clean‐up and separation system for the determination of betaine, l ‐carnitine and choline in human urine using column‐switching ion chromatography with nonsuppressed conductivity detection was developed in this work. A self‐packed pretreatment column (50 × 4.6 mm, i.d.) was used for the extraction and clean‐up of betaine, l ‐carnitine and choline. The separation was achieved using self‐packed cationic exchange column (150 × 4.6 mm, i.d.), followed by nonsuppressed conductivity detection. Under optimized experimental conditions, the developed method presented good analytical performance, with excellent linearity in the range of 0.60–100 μg mL−1 for betaine, 0.75–100 μg mL−1 for l ‐carnitine and 0.50–100 μg mL−1 for choline, with all correlation coefficients (R2) >0.99 in urine. The limits of detection were 0.15 μg mL−1 for betaine, 0.20 μg mL−1 for l ‐carnitine and 0.09 μg mL−1 for choline. The intra‐ and inter‐day accuracy and precision for all quality controls were within ±10.32 and ±9.05%, respectively. Satisfactory recovery was observed between 92.8 and 102.0%. The validated method was successfully applied to the detection of urinary samples from 10 healthy people. The values detected in human urine using the proposed method showed good agreement with the measurement reported previously.  相似文献   

10.
《Electroanalysis》2017,29(11):2423-2436
Herein, a facile procedure was developed for designing an electrochemical sensor based on pencil graphite electrode modified with electrochemically synthesized silver and copper nanoparticles (AgNP and CuNP) supported on functionalized multiwalled carbon nanotubes (f MWCNTs). The electrochemical and morphological characterization was carried out by cyclic voltammetry, Electrochemical Impedance Spectroscopy, Powder X‐ray diffraction, Field Emission Scanning Electron Microscopy, Transmission electron microscopy and Atomic Force Microscopy. The designed sensor exhibited electrocatalytic behavior towards the reduction of Imazethapyr. Results indicates the combination of AgNPs, CuNPs and f MWCNTs on PGE produced remarkable enhancement in electrocatalytic and sensing properties. Various electro‐kinetic parameters like Rct, kapp, n, α, E0, k0, Γ, D and k have been evaluated by CV, impedance and Chronoamperometric studies. The electrochemical performance was improved by optimizing the effect of pH, scan rate, amount of f MWCNTs and deposition parameters of AgNP and CuNP. The sensor was efficaciously applied for determination of Imazethapyr and exhibited a linear correlation in the concentration range of 0.01–5.0 μg mL−1 with low detection limits, 0.159 ng mL−1 using AdSWV. The fabricated sensor exhibited good accuracy, acceptable stability and high efficacy for quantitative determination of Imazethapyr in real samples with notable recoveries ranging from 98 % to 100.2 %.  相似文献   

11.
《Electroanalysis》2002,14(24):1699-1706
An application of a partial least squares calibration method for the simultaneous voltammetric determination of indomethacin, acemethacin, piroxicam and tenoxicam is suggested. It was shown that it is possible to resolve complex mixtures of analytes even when they have strongly overlapped signals. In order to check the proposed method, statistical analysis of the results was performed by mean of hypothesis tests. The method developed was applied to the electrochemical reduction region of four anti‐inflammatory drugs and allowed the drugs to be quantified at concentrations between 0.52 and 4.09 μg mL?1 for acemethacin, 0.44 and 3.50 μg mL?1 for indomethacin, 0.43 and 3.40 μg mL?1 for piroxicam, and 0.42 and 3.30 μg mL?1 for tenoxicam with good results. The average absolute value of relative errors was 2.25%, 4.31%, 1.68% and 2.49%, respectively.  相似文献   

12.
An electrochemical sensor based on raffia derived porous carbon (RPC) and polyaniline (PANI) composite functional glass carbon electrode (GCE) was constructed for imidacloprid (IMI) determination. PANI nanowire arrays were deposited on RPC surface uniformly without aggregations. The electrochemical response of IMI at RPC@PANI/GCE is about four times than that at bare GCE, indicating high electrocatalytic activity of RPC@PANI towards IMI reduction. The prepared sensor also offers a wide linear range of 0.1–70 μg mL−1 for IMI determination with a limit of detection (LOD) of 0.03 μg mL−1. In addition, it offers high recoveries with testing real samples.  相似文献   

13.
A novel kinetic method for the determination of trace amounts of Co(II) has been developed. The proposed method based on the catalytic effect of Co(II) on the oxidation of xylenol orange tetra sodium salt by H2O2 in the presence of cationic surfactant (N‐dodecylpyridinium chloride). Co(II) at μg.mL?1 was determined spectrophotometrically by measuring the decrease in the absorbance of xylenol orange at 577 nm by the differential method. The method is precise, selective, and sensitive. The detection limit of the procedure was 0.058 μg.mL?1. The relative standard deviation for the replicate determination (n = 6) of 0.7 μg.mL?1 was 1.285%. The results compared satisfactorily with those of atomic absorption spectrometry. The method was successful for the analysis of Co(II) in veterinary and synthetic samples.  相似文献   

14.
A quick and inexpensive validated method, based on sample treatment by liquid–liquid microextraction followed by liquid chromatography (LC) coupled with ultraviolet tandem fluorescence detection is proposed for the determination of 15 multiclass pollutants both in serum and in saliva, as a simple and easy to draw matrix. The method was set up and validated according to European guidelines. The compounds of interest include some endocrine‐disrupting chemicals (i.e. bisphenol A, bisphenol B, bisphenol E, bisphenol F, bisphenol AF, bisphenol A diglycidyl ether, bisphenol M, diethylhexyl phthalate, monoethylhexyl phthalate, triclosan and 4‐nonylphenol), as well as other pollutants belonging to the class of volatile organic compounds (2‐chlorophenol, 1,2 dichlorobenzene, 1,2,4,5‐tetrachlorobenzene). The limits of quantifications ranged from 2.28 × 10?3 μg mL?1 (bisphenol A diglycidyl ether) to 6.29 μg mL?1 (diethylhexyl phthalate), while those of detection ranged from 0.068 × 10?3 μg mL?1 (bisphenol A diglycidyl ether) to 1.031 μg mL?1 (diethylhexyl phthalate). To test method suitability, it was applied to real saliva and serum samples of healthy human volunteers and was found to meet the demands of the laboratories handling simple and relatively inexpensive equipment for screening oriented at rapid and reliable contamination assessment of a population.  相似文献   

15.
In this work, a fast, easy, and efficient dispersive liquid–liquid microextraction method based on solidification of floating organic drop followed by high‐performance liquid chromatography with UV detection was developed for the separation/preconcentration and determination of the drug valsartan. Experimental design was applied for the optimization of the effective variables (such as volume of extracting and dispersing solvents, ionic strength, and pH) on the extraction efficiency of valsartan from urine samples. The optimized values were 250.0 μL ethanol, 65.0 μL 1‐dodecanol, 4.0% w/v NaCl, pH 3.8, 1.0 min extraction time, and 4.0 min centrifugation at 4000 rpm min?1. The linear response (r2 = 0.997) was obtained in the range of 0.013–10.0 μg mL?1 with a limit of detection of 4.0 ng mL?1 and relative standard deviations of less than 5.0 % (n = 6).  相似文献   

16.
A sensitive reagent system is proposed for the determination of cyanide and hydrogen cyanide in various environmental samples. The method is based on the conversion of cyanide into cyanogen bromide followed by its reaction with pyridine to form glutaconic aldehyde. The glutaconic aldehyde so formed is coupled with p‐aminoacetophenone forming yellow‐orange polymethine dye measured at 445 nm. The colour system obeys Beer's law in the range of 0.01–0.16 ppm of cyanide inaqeous phase and 0.002–0.03 ppm in extracting system. The molar absorptivity and Sandell's sensitivity were found to be 6.51 × 105 l mol?1 cm?1 and 0.0001 μg cm?2, respectively. The method has been successfully applied for the determination of cyanide in air, industrial effluent, biological samples, and in the pesticide acrylonitrile.  相似文献   

17.
The objective of this work is to develop and validate spectrophotometric method for the determination of piroxicam in commercial dosage forms. The method is based on the chelation of the drug with Fe(III) to form pink coloured metal chelate at room temperature which absorbs maximally at 504 nm. Beer's law is obeyed over the concentration range of 8–160 μg mL?1 (A = 1.07 × 10?3 + 7.75 × 10?3 C). Under the optimized experimental conditions, proposed method is validated as per the International Conference on Harmonisation guidelines. The limits of detection and quantitation for the proposed method are 0.775 and 2.348 μg mL?1, respectively. The proposed method has been successfully applied to the determination of piroxicam in commercial dosage forms. The results are compared with the reference El‐Ries et al. spectrophotometric method.  相似文献   

18.
A new method for the determination of isoniazid by using 1,2‐naphthoquinone‐4‐sulfonic sodium as the chemical derivative chromogenic reagent is established. The method is based on a condensation reaction to measure the pink compound produced by the reaction of isoniazid with 1,2‐naphthoquinone‐4‐sulfonic sodium in pH 13.00 buffer solution. The stoichiometric ratio of the compound is 1:1, and its maximum absorption wavelength is at 460 nm, ? = 1.18 × 104 L·mol?1 cm?1. Beer's law is perfectly obeyed in the range of 0.50?30 μg.mL?1 of isoniazid. The linear regression equation is A = 0.0185 + 0.11056C (mol.L?1), with 0.9994 of a linear regression correlation. The detection limit is 0.40 μg.mL?1, RSD is 0.48%, and average recovery is over 99.3%. This paper further optimizes the determination of isoniazid compared to the previous methods, and the kinetic property and reaction mechanism are studied intensively. This proposed method has been successfully applied to the determination of isoniazid in tablets of isoniazid with satisfactory results.  相似文献   

19.
A new optical chemical sensor is established for sensitive and selective spectrophotometric detection of copper based on the immobilization of 3‐(2‐methyl‐2,3‐dihydro‐1,3‐benzothiezol‐2‐yl)‐2H‐chromen‐2‐one on a triacetylcellulose membrane. Copper ions react with the immobilized ligand and cause an increase in the absorption of the membrane at 550 nm in universal buffer solution at pH = 6. The effects of pH, indicator concentration and reaction time on the immobilization of the ligand were studied. This optode exhibits a linear range of 7.0 × 10?7 to 1 × 10?4 mol l?1 of copper ion concentration with a limit of detection of 3.0 × 10?7 mol l?1. The response time of the newly designed optode is within 3 min. The effect of different possible interfering species was investigated and it was found that the sensor has very good selectivity. The proposed sensor benefits from advantages such as low cost, high stability, low detection limit, fast response time, reproducibility, relatively long lifetime, and good selectivity for Cu2+ ion determination among a large number of alkali, alkaline earth, transition and heavy metal ions. The sensor can readily be regenerated with thiourea solution and its response is reversible and reproducible (relative standard deviation < 1.4%). The proposed optode was applied successfully for the determination of Cu(II) in various samples.  相似文献   

20.
A novel method for the indirect determination of sodium cefotaxime by the extraction‐flotation of cuprous thiocyanate is described in this paper. The experiment indicated that the degradation of sodium cefotaxime took place in the presence of 0.20 M sodium hydroxide in a boiling water bath for 40 min. At pH 4.0, the thiol group (‐SH) of the degradation product of sodium cefotaxime could reduce Cu(II) to Cu(I) for the formation of the emulsion CuSCN precipitation in the presence of ammonium thiocyanate. By determining the residual amount of Cu(II) in the solution and calculating the flotation yield of CuSCN, the indirect determination of sodium cefotaxime can be achieved. When the concentration of Cu(II) was 5.0 μg mL?1, a good linear relationship was obtained between the flotation yield of CuSCN and the amount of sodium cefotaxime in the range of 0.50~20 μg mL?1. The linear equation is E = 1.329 + 2.654C with a correlation coefficient r = 0.9988. The detection limit of sodium cefotaxime of this proposed method evaluated by calibration curve (3σ/k) was found to be 0.39 μg mL?1. Every parameter has been optimized and the reaction mechanism has been studied. This method has been successfully applied to the determination of sodium cefotaxime in pharmaceutical formulations, human serum, and urine samples, respectively. Analytical results obtained with this novel method are satisfactory.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号