 共查询到20条相似文献,搜索用时 437 毫秒
1.
A new discrimination method, called hit quality index (HQI)-voting, that uses the HQI for discriminant analysis has been developed. HQI indicates the degree of spectral matching between two spectra as known. In this method, a library sample yielding the highest HQI value for an unknown sample was initially searched and a group containing this sample was chosen as the group for the unknown sample. When overall spectral features of two groups are quite close to each other, many library samples with similar HQI values could be available for an unknown sample. In this situation, the simultaneous consideration of multiple votes (several library samples with close HQI values) for final decision would be more robust. In order to evaluate the discrimination performance of HQI-voting, three different near-infrared (NIR) spectroscopic datasets composed of two sample groups were used: (1) domestic and imported sesame samples, (2) domestic and imported Angelica gigas samples, and (3) diesel and light gas oil (LGO) samples. For the purpose of comparison, principal component analysis–linear discriminant analysis (PCA–LDA), partial least squares–discriminant analysis (PLS–DA) as well as k-nearest neighbor (k-NN) were also performed using the same datasets and the resulting accuracies were compared. The discrimination performances improved with the use of HQI-voting in comparison with those resulted from PCA–LDA and PLS–DA. The overall results support that HQI-voting is a comparable discrimination method to that of existing factor-based multivariate methods.  相似文献   

2.
通过测定间二氯苯中的杂质含量得到间二氯苯的纯度。分别采用高效液相色谱法(HPLC–UVD)和气相色谱法(GC–FID)测定间二氯苯中主要杂质邻、对二氯苯的含量,结果表明两种方法所得杂质含量一致;用高效液相色谱法(HPLC)测定间二氯苯中杂质苯的含量,卡尔费休(Karl Fischer)法测定水分含量,热重法(TGA)进行灰分测定,电感耦合等离子体质谱(ICP–MS)法测定无机杂质含量。最终确定间二氯苯的纯度为99.60%,扩展不确定度为0.03%(k=2)。该方法测定结果准确可靠,具有可溯源性。  相似文献   

3.
In this work, a humidity independent mass spectrometric method was developed for rapid analysis of gas phase chemicals. This method is based upon ambient proton transfer reaction between gas phase chemicals and charged water droplets, in a reaction chamber with nearly saturate humidity under atmospheric pressure. The humidity independent nature enables direct and rapid analysis of raw gas phase samples, avoiding time- and sample-consuming sample pretreatments in conventional mass spectrometry methods to control sample humidity. Acetone, benzene, toluene, ethylbenzene and meta-xylene were used to evaluate the analytical performance of present method. The limits of detection for benzene, toluene, ethylbenzene and meta-xylene are in the range of ∼0.1 to ∼0.3 ppbV; that of benzene is well below the present European Union permissible exposure limit for benzene vapor (5 μg m−3, ∼1.44 ppbV), with linear ranges of approximately two orders of magnitude. The majority of the homemade device contains a stainless steel tube as reaction chamber and an ultrasonic humidifier as the source of charged water droplets, which makes this cheap device easy to assemble and facile to operate. In addition, potential application of this method was illustrated by the real time identification of raw gas phase chemicals released from plants at different physiological stages.  相似文献   

4.
An ion chromatographic (IC) method for the determination of oxalate in plasma was developed. The method exploits a rapid and simple sample preparation step that substantially reduces the plasma chloride level to facilitate the oxalate determination. The chloride is removed as silver chloride by using a cation-exchange resin in the silver cation form. The dependence on chloride concentration and pH was evaluated. The oxalate recovery in plasma samples was found to be 93 ± 18% (n=4 trials) according to a standard addition study. A comparison of the IC method with an enzymatic method indicated that both methods measure the same oxalate concentration over the range examined, 5–300 μM. Furthermore, the comparison involved a correlation study that allowed cross-validation of the two methods, suggesting that neither is adversely affected by interferences. The detection limit of the IC method was 0.5 μM or 4.4 ng oxalate.  相似文献   

5.
Aflatoxin analysis, with post-column derivatization using a photochemical reactor for enhanced detection (PHRED) system for derivatization, has been compared to the officially recognized iodine and Kobra cell derivatization systems. This photochemical system has been extensively used for screening peanuts by some U.S. Department of Agriculture laboratories for many years. From their periodic method checks, using standard spiked samples, an 80 sample series with each of the 3 derivatization methods was statistically analyzed. Paired comparisons, using the same sample extract, were also made between the PHRED and one of the other 2 methods, among laboratories in 4 different countries, on a variety of naturally contaminated commodity products. The differences between the techniques were not significant for peanuts, but for corn the photochemical system consistently gave slightly higher values for aflatoxins B1 and B2 than the Kobra cell method. However, a comparison of all sample results showed no significant differences between methods. The Pearson correlation coefficients for aflatoxin B1 in 102 test samples and aflatoxin B2 in 94 test samples were 0.9994 and 0.9874, respectively. The probability factor was P < 0.0001, and the t-tests were not significantly different except for the corn. These indicated that the PHRED system is equivalent to the iodine and Kobra cell methods for peanuts relative to the current official procedures, but the PHRED system has a slightly high bias for corn compared to the iodine and Kobra cell systems.  相似文献   

6.
A new method for the detection of trace elements in polar ice cores using laser ablation with subsequent inductively coupled plasma mass spectrometry analysis is described. To enable direct analysis of frozen ice samples a special laser ablation chamber was constructed. Direct analysis reduces the risk of contamination. The defined removal of material from the ice surface by means of a laser beam leads to higher spatial resolution (300– 1000 μm) in comparison to investigations with molten ice samples. This is helpful for the detection of element signatures in annual layers of ice cores. The method was applied to the successful determination of traces for the elements Mg, Al, Fe, Zn, Cd, Pb, some rare-earth elements (REE) and minor constituents such as Ca and Na in ice cores. These selected elements serve as tracer elements for certain sources and their element signatures detected in polar ice cores can give hints to climate changes in the past. We report results from measurements of frozen ice samples, the achievable signal intensities, standard deviations and calibration graphs as well as the first signal progression of 208Pb in an 8,000-year-old ice core sample from Greenland. In addition, the first picture of a crater on an ice surface burnt by an IR laser made by cryogenic scanning electron microscopy is presented.  相似文献   

7.
Developments in continuous‐flow isotope ratio mass spectrometry have made possible the rapid analysis of δ13C in CO2 of small‐volume gas samples with precisions of ≤0.1‰. Prior research has validated the integrity of septum‐capped vials for collection and short‐term storage of gas samples. However, there has been little investigation into the sources of contamination during the preparation and analysis of low‐concentration gas samples. In this study we determined (1) sources of contamination on a Gasbench II, (2) developed an analytical procedure to reduce contamination, and (3) identified an efficient, precise method for introducing sample gas into vials. We investigated three vial‐filling procedures: (1) automated flush‐fill (AFF), (2) vacuum back‐fill (VBF), and (3) hand‐fill (HF). Treatments were evaluated based on the time required for preparation, observed contamination, and multi‐vial precision. The worst‐case observed contamination was 4.5% of sample volume. Our empirical estimate showed that this level of contamination results in an error of 1.7‰ for samples with near‐ambient CO2 concentrations and isotopic values that followed a high‐concentration carbonate reference with an isotope ratio of ?47‰ (IAEA‐CO‐9). This carry‐over contamination on the Gasbench can be reduced by placing a helium‐filled vial between the standard and the succeeding sample or by ignoring the first two of five sample peaks generated by each analysis. High‐precision (SD ≤0.1‰) results with no detectable room‐air contamination were observed for AFF and VBF treatments. In contrast, the precision of HF treatments was lower (SD ≥0.2‰). VBF was optimal for the preparation of gas samples, as it yielded faster throughput at similar precision to AFF. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

8.
A rapid and automated method was developed for the determination of bacterial contamination and using Escherichia coli as a model microorganism. The method involves the use of a sensor connected to a flow injection (FI) system. The sample is introduced through a flow injection system into a piezoelectric quartz crystal (PQC) flow-cell. The resulting change of the resonance frequency is related to the bacterial contamination in the sample. The parameters associated with the flow system and the conditions for introducing the sample culture were optimized. Calibration curves are linear in the range from 3.2?×?107 to 3.2?×?109 cfu per mL-1, with a correlation coefficient of 0.997. The reproducibility was between 3.1 and 7.6%, and the detection limit is 1.1?×?107 cfu per mL-1. The method allowed the determination of bacterial contamination in residual water and in samples of milk and chicken stock within 5 h, while the conventional plate count method requires 24 to 48 h. The results obtained by these two methods are in good agreement.
Figure
A rapid and automated method for the determination of bacterial growth contamination is proposed and Escherichia coli was used as a model microorganism. The methodology involves the use of a piezoelectric quartz crystal (PQC) sensor connected to a flow injection (FI) system. The sample was introduced through the FI system and the resonant frequency change of PQC is related to the bacterial contamination in the sample. The method allows the successful determination of bacteria in residual water and several food samples  相似文献   

9.
The establishment of drug vapor pressure reference values provides valuable information in the development of vapor sensing devices for drug detection. The purpose of this work was to determine equilibrium headspace vapor pressures for commercial and illicit drug samples for use in such applications. Samples of cocaine, both free base and hydrochloride forms, and heroin hydrochloride were evaluated. The procedure used to measure the vapor pressures was a modification of a previously published method. Vapor pressure values at 20 degrees C previously reported for cocaine free base range from 0.37 x 10(-7) to 1.20 x 10(-7) Torr. The vapor pressure value determined in this study was 2.96 x 10(-7) Torr. It is likely that the discrepancies are due to differences in experimental conditions, varying sources of samples, and uncertainty in the methodologies. When the values were compared for commercial (99% purity) and illicit (unknown purity) sources of cocaine free base, there were no statistical differences in the projected room temperature (20 degrees C) vapor pressure values. However, the commercial and illicit samples of cocaine hydrochloride did show statistical differences. Although no comparison was made with the vapor pressure values for a pure, commercial sample, the vapor pressures of heroin hydrochloride (81% purity) at various temperatures were determined using the method developed for cocaine and are reported in this paper.  相似文献   

10.
The analytical performances of a manual and a partially automated chemiluminescent (CL) assay, of total antioxidant capacity (TAC) were assessed. In both cases the light emitting reaction involved luminol, horseradish peroxidase and hydrogen peroxyde, but the emission kinetics and the parameters taken into account to calculate TAC values were completely different. The major characteristics expressing the quality of the two analytical methods, i.e. inaccuracy, repeteability and reproducibility, sensitivity, time required for the analysis and detection limit, were estimated by using standard solutions of Trolox. The reliability of the automated method, in comparison with the more validated manual one, was demonstrated testing food samples such as honey, wine and dietary supplements and performing a statistical analysis of the results. The comparison of the two series of data by t-test resulted in p values in the range 0.1-0.01. The time required for the analysis of each sample was reduced to one third using the automated method.  相似文献   

11.
A new method for the detection of trace elements in polar ice cores using laser ablation with subsequent inductively coupled plasma mass spectrometry analysis is described. To enable direct analysis of frozen ice samples a special laser ablation chamber was constructed. Direct analysis reduces the risk of contamination. The defined removal of material from the ice surface by means of a laser beam leads to higher spatial resolution (300-1000 microm) in comparison to investigations with molten ice samples. This is helpful for the detection of element signatures in annual layers of ice cores. The method was applied to the successful determination of traces for the elements Mg, Al, Fe, Zn, Cd, Pb, some rare-earth elements (REE) and minor constituents such as Ca and Na in ice cores. These selected elements serve as tracer elements for certain sources and their element signatures detected in polar ice cores can give hints to climate changes in the past. We report results from measurements of frozen ice samples, the achievable signal intensities, standard deviations and calibration graphs as well as the first signal progression of 205Pb in an 8,000-year-old ice core sample from Greenland. In addition, the first picture of a crater on an ice surface burnt by an IR laser made by cryogenic scanning electron microscopy is presented.  相似文献   

12.
In the present study, we developed a novel digital coding combination analysis (DCCA) to analyze the gene mutation based on the sample combination principle. The principle is that any numerically named sample is divided into two groups, any two samples are not grouped in the same two groups, and any sample can be tested within the detection limit. Therefore, we proposed a specific combination that N samples were divided into M groups. Then N samples were analyzed, which could obtain the mutation results of M mixed groups. If only two groups showed positive (mutant type) signals, the same sample number from two positive signal groups would be the positive sample, and the remaining samples were negative (wild type). If three groups or more exhibited positive results, the same sample number from three positive signal groups would be the positive sample. If some samples remained uncertain, individual samples could be analyzed on a small scale. In the present study, we used the two genotypes of a mutation site (A5301G) to verify whether it was a useful and promising method. The results showed that we could quantitatively detect mutations and demonstrate 100% consistent results against a panel of defined mixtures with the detection limit using pyrosequencing. This method was suitable, sensitive, and reproducible for screening and analyzing low-frequency mutation samples, which could reduce reagent consumption and cost by approximately 70–80% compared with conventional clinical methods.  相似文献   

13.
The potential of a gas chromatographic method employing high-resolution time-of-flight (TOF) mass spectrometry was evaluated for detection of polybrominated diphenyl ethers (PBDEs) in the environmental matrices represented by fish and river sediment. Two ionisation techniques, viz. electron ionisation (EI) and negative ion chemical ionisation (NICI), the latter with methane as a reagent gas, were used in this study. While the instrumental lowest calibration levels (LCLs) obtained in El were in the range from 1 to 5 pg, their values ranged between 10 to 250 fg in NICI mode. This enhancement in detectability of target analytes enabled identification/quantification of even minor PBDE congeners, and consequently, improved characterisation of particular sample contamination patterns. In addition, this method allowed estimation of the PCB levels in examined samples. CB 153 was used as a contamination marker in this study.  相似文献   

14.
A marine reference material, IAEA-140, prepared with a macroalgae (Fucus sp.) was recently produced by the International Atomic Energy Agency and certified for trace and major elements and for methylmercury (MeHg). Certification of this material was achieved as an outcome of an international analytical intercomparison study which resulted in 116 independent sets of results reported by participants from 54 countries. The statistical evaluation of the collected data and the criteria used for assignment of the mean and uncertainty values are described. The analysis of data allowed to certify concentration values for 24 elements and MeHg, and to provide information values for another 10 elements. Regarding the elements which could be given certified values, between two and eight different instrumental methods were used to measure metal concentrations, and four independent analytical procedures were used to measure MeHg concentrations. In order to assess the results of the certification procedure, a comparison was made between the certified values obtained from the world-wide intercomparison results and the values obtained from a small subgroup of well-qualified laboratories. The means and 95% confidence intervals for reference values obtained by the two methods are similar for most elements showing that the usual method of certification used by the IAEA, based on large groups of participants, is indeed pertinent.  相似文献   

15.
This work reports on the development and validation of a small-scale and efficient SPE-HPLC-UV method for the simultaneous determination of the most used herbicides (diuron, hexazinone, and tebuthiuron) applied to soil and soil treated with sugar cane vinasse (soil-vinasse) in areas where sugar cane crops are grown in the state of São Paulo, Brazil. The analytical procedure was optimized for solvent extraction and HPLC-UV conditions. Extraction and clean-up were combined in a single step employing solid-phase extraction, avoiding sophisticated techniques, organic-solvent-water mixtures and consequently a longer concentration step. Recovery studies with soil and soil-vinasse samples spiked at two herbicides levels (around 0.25 and 2.0 mg kg−1) and sample stability (sample frozen for 20 days before analysis) were applied as parameters to control the efficiency of the method. Good accuracy and precision were achieved with average recoveries ranging from 78% to 120% and relative standard deviations less than 10% throughout the whole recovery test. The method's limit of detection ranged between 0.025 and 0.050 mg kg−1 for diuron, hexazinone, and tebuthiuron in soil and soil-vinasse. The feasibility of this method was applied to determine the herbicide half-lives (t1/2) in soil and soil-vinasse in a laboratory study. Sugar cane vinasse added to soil increased the degradation of diuron and tebuthiuron (p < 0.05), reducing the t1/2 from 80 to 7 days and 128 to 73 days, respectively. This method is presented as an alternative which could be applied to assess herbicide behavior in soil in order to prevent water contamination and to contribute to establish pesticide limits in soil.  相似文献   

16.
A relative method for the determination of oxygen in steel via the 16O(n,p)16N reaction by means of 14-MeV neutrons is described. A standard is irradiated immediately behind the sample and the induced activities are counted simultaneously with two separate but identical detector systems. The standard mixture (ca. 5 g of graphite plus iron oxide containing 80 mg of oxygen per g) is compressed into a steel capsule of the same external dimensions as the samples (26 mm diameter, 9 mm thick). Dimensional tolerances, choice and purity control of the oxygen compound and preparation of the standard mixture are discussed. Fast neutron shielding, absorption of fast neutrons, self-absorption of the 16N /gg-rays and the average neutron flux in sample and standards are considered and a total correction factor is established. Flux inhomogeneities and differences in counting geometry and discriminator setting can be determined by irradiation and counting of two identical standards. The accuracy of this method was checked by comparison of the results with those of the reducing fusion method; satisfactory agreement was observed, although the activation results tended to be slightly higher. The mean long-term standard deviation for analysis of a given sample over a period of 6 months was found to be ±3%.  相似文献   

17.
Based on dipole moment measurements, a study was made of the keto-enol equilibria of five alpha substituted benzoylacetanilide derivatives in two non-polar and one polar solvents at 30°C. The enol mole fractions of the compounds investigated were determined by analysis of their ultraviolet spectra. The same type of study was extended to salicylanilide for its resemblance to the enol tautomer of these compounds. A deduction of the most probable configurations of the keto and enol forms was tentatively made through a comparison between the dipole moments of some suggested configurations for these forms of benzoylacetanilide and those measured in benzene for the alpha methyl benzoylacetanilide and salicylanilide, respectively. These inferred configurations were used to calculate the dipole moments of both tautomers of the other compounds, and consequently, the dipole moment values of their tautomeric mixtures in dioxane and chloroform. A comparison between the dipole moment values of their tautomeric mixtures in dioxane and chloroform. A comparison between the dipole moment values calculated in this way and those measured indicated a solute-solvent interaction with dioxane, which chloroform behaved as a non-interacting solvent.  相似文献   

18.
Since recently Mid-Infrared Spectroscopy is being used in the petrol industry for determining important chemical-physical properties of gasoline. This technique enables to achieve results similar to those obtainable with standard methods at shorter times, lower costs and safer sample handling. This can be obtained by employing multivariate regression models in the framework of a chemometric analytical approach. In the present work some gasoline properties including density, Reid vapor pressure, Research Octane Number, aromatic hydrocarbons content and fraction recovered at 70 degrees C were determined with standard methods (ISO, CEN, ASTM) on 93 samples of unleaded gasoline produced in an oil refinery. The same samples were also analyzed by FT-IR spectrophotometry, recording absorptions of seven characteristic bands. The obtained values of chemical-physical and spectroscopic properties were used to develop and validate a multivariate regression model. This established an experimental correlation between these two sets of variables derived from the same gasoline samples. The model was able to correctly predict the chemical physical properties of a set of unknown gasoline samples produced in the same refinery starting from the spectroscopic ones.  相似文献   

19.
An analytical technique was developed to analyze light non-methane hydrocarbons (NMHC), including ethane, propane, iso-butane, n-butane, iso-pentane, n-pentane, n-hexane, isoprene, benzene and toluene from whole air samples collected in 2.5l-glass flasks used by the National Oceanic and Atmospheric Administration, Earth System Research Laboratory, Global Monitoring Division (NOAA ESRL GMD, Boulder, CO, USA) Cooperative Air Sampling Network. This method relies on utilizing the remaining air in these flasks (which is at below-ambient pressure at this stage) after the completion of all routine greenhouse gas measurements from these samples. NMHC in sample aliquots extracted from the flasks were preconcentrated with a custom-made, cryogen-free inlet system and analyzed by gas chromatography (GC) with flame ionization detection (FID). C2-C7 NMHC, depending on their ambient air mixing ratios, could be measured with accuracy and repeatability errors of generally < or =10-20%. Larger deviations were found for ethene and propene. Hexane was systematically overestimated due to a chromatographic co-elution problem. Saturated NMHC showed less than 5% changes in their mixing ratios in glass flask samples that were stored for up to 1 year. In the same experiment ethene and propene increased at approximately 30% yr(-1). A series of blank experiments showed negligible contamination from the sampling process and from storage (<10 pptv yr(-1)) of samples in these glass flasks. Results from flask NMHC analyses were compared to in-situ NMHC measurements at the Global Atmospheric Watch station in Hohenpeissenberg, Germany. This 9-months side-by-side comparison showed good agreement between both methods. More than 94% of all data comparisons for C2-C5 alkanes, isoprene, benzene and toluene fell within the combined accuracy and precision objectives of the World Meteorological Organization Global Atmosphere Watch (WMO-GAW) for NMHC measurements.  相似文献   

20.
The objective of this work was to compare the results obtained by the relative INAA and k 0-INAA methods for the same input parameters (sample mass, nuclear data, net peak area for the same gamma line and the same measurement and same cooling and measurement times). In total eight environmental soil and sediment reference materials (RM) or certified reference materials (CRM) from different producers were analysed. In this work only the recommended or certified values were considered, allowing comparison of the two methods for 30 elements. The results point out that k 0-INAA possesses superior qualities compared to relative INAA, being insensitive to flux gradients, and independent of recommended/certified values in RMs/CRMs, often used as standards in relative INAA.  相似文献   