首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 726 毫秒
1.
A minicolumn packed with poly(aminophosphonic acid) chelating resin incorporated in an on-line preconcentration system for flame atomic-absorption spectrometry was used to determine ultratrace amounts of lead in mussel samples at microg L(-1) level. The preconcentrated lead was eluted with hydrochloric acid and injected directly into the nebulizer for atomization in an air-acetylene flame for measurement. The performance characteristics of the determination of lead were: preconcentration factor 26.8 for 1 min preconcentration time, detection limit (3sigma) in the sample digest was 0.25 microg g(-1) (dry weight) for a sample volume of 3.5 mL and 0.2 g sample (preconcentration time 1 min), precision (RSD) 2.3% for 25 microg L(-1) and 2.0% for 50 microg L(-1). The sampling frequency was 45 h(-1). The method was highly tolerant of interferences, and the results obtained for the determination of lead in a reference material testify to the applicability of the proposed procedure to the determination of lead at ultratrace level in biological materials such as mussel samples.  相似文献   

2.
A system for on-line preconcentration and determination of lead by flame atomic absorption spectrometry (FAAS) was proposed. It was based on the sorption of lead(II) ions on a minicolumn of polyurethane foam loaded with 2-(2-thiazolylazo)-5-dimethylaminophenol (TAM). The optimisation step was carried out using two-level full factorial and Doehlert designs for the determination of the optimum conditions for lead preconcentration. The proposed procedure allowed the determination of lead with a detection limit of 2.2 microg L(-1), and a precision, calculated as relative standard deviation (RSD), of 2.4 and 6.8 for a lead concentration of 50.0 and 10.0 microg L(-1), respectively. A preconcentration factor of 45 and a sampling frequency of 27 samples per hour were obtained. The recovery achieved for lead determination in the presence of several cations demonstrated that this procedure has enough selectivity for analysis of environmental samples. The validation was carried out by analysis of certified reference material. This procedure was applied to lead determination in natural food.  相似文献   

3.
A new, automatic method for the clean-up, preconcentration, separation, and quantitation of nonsteroidal anti-inflammatory drugs (NSAIDs) in biological samples (human urine and serum) using solid-phase extraction coupled on-line to capillary electrophoresis is proposed. Automatic pretreatment is carried out by using a continuous flow system operating simultaneously with the capillary electrophoresis equipment, to which it is linked via a laboratory-made mechanical arm. This integrated system is controlled by an electronic interface governed via a program developed in GWBasic. Capillary electrophoresis is conducted by using a separation buffer consisting of 20 mM NaHPO4, 20 mM beta-cyclodextrin and 50 mM SDS at pH 9.0, an applied potential of 20 kV and a temperature of 20 degrees C. The analysis time is 10 min and the detection limits were between 0.88 and 1.71 microg mL(-1). Automatic clean-up and preconcentration is accomplished by using a C-18 minicolumn and 75% methanol as eluent. The limit of detection of NSAIDs can be up to 400-fold improved when using sample clean-up. The extraction efficiency for these compounds is between 71.1 and 109.7 microg mL(-1) (RSD 2.0-7.7%) for urine samples and from 77.2 to 107.1 microg mL(-1) (RSD 3.5-7.1%) for serum samples.  相似文献   

4.
A new simple and reliable method has been developed to separate and preconcentrate trace copper ion in drinking water and tea samples for subsequent measurement by flame atomic absorption spectrometry (FAAS). The copper ions are adsorbed quantitatively during passage of aqueous solutions through Amberlyst 36 cation exchange resin. After the separation and preconcentration stage, the analyte was eluted with a potassium cyanide solution and determined by FAAS. Different factors including pH of sample solution, sample volume, amount of resin, flow rate of aqueous solution, volume and concentration of eluent, and matrix effects for preconcentration were examined. The analytical figures of merit for the determination of copper are as follows: analytical detection limit (3 sigma), 0.26 microg/L; precision (RSD), 3.1% for 100 microg/L; enrichment factor, 200 (using 1000 mL of sample solution and 5 mL of eluent); time of analysis, 3.5 h (for obtaining enrichment factor of 200); capacity of resin, 125 mg/g. The method was applied for copper determination by FAAS in tap water, commercial natural spring water, commercial treated drinking water, and commercial tea bag sample. The accuracy of the method is confirmed by analyzing tea leaves (GBW 07605). The results demonstrated good agreement with the certified values.  相似文献   

5.
A flow injection analysis-flame atomic absorption spectrometric method for the determination of cadmium in seawater was developed with the aim of yielding a sensitive assay with a low detection limit. The method employs a field flow preconcentration technique involving a minicolumn containing Amberlite XAD-4 impregnated with the complexing agent 4-(2-pyridylazo) resorcinol. A Plackett-Burman 2(7)x3/32 design for seven factors (sample pH, sample flow rate, eluent volume, eluent concentration, eluent flow rate, ethanol percentage in the eluent and minicolumn diameter) was carried out in order to find the significant variables affecting the field continuous preconcentration system (FCPS) and the flow injection elution manifold for cadmium determination in seawater samples by flame atomic absorption spectrometry. Cadmium can be preconcentrated with an enrichment factor of 1053 for a sample volume of 200 mL and a preconcentration time of 57 min. In these experimental conditions, the method provides a linear relationship between absorbance and cadmium concentration in the range from 22-1900 ng L(-1), with a detection limit (3SD) of 6 ng L(-1). The precision (expressed as relative standard deviation) for eleven independent determinations reached values of 8.9-0.8% in cadmium solutions of 50-700 ng L(-1). Analysis of certified reference materials (SLEW-3 and NASS-5) showed good agreement with the certified value. This procedure was applied to the determination of cadmium in seawater from Galicia (Spain).  相似文献   

6.
The 1,3-diaminepropane-3-propyl-anchored silica gel (DAPPS) was successfully employed as a sorbent in a spectrophotometric flow system for the preconcentration of Cu(2+) in digests of biological materials (maize powder, soybean, citrus leaves, corn stalks) as well as water samples (river, stream, streamlet, springwater and well). The system presented a minicolumn packed with DAPPS, where the sample solution was passed through it for a period of time, and subsequently, an eluent solution, stripped-out the retained analyte which was further determined with DDTC at 460 nm. The better preconcentration conditions utilized were: 120s loading, 60s elution, 30s regeneration of the column, loading flow rate 6.5 ml min(-1), buffer solution for the preconcentration and regeneration of the column-borate buffer pH 8.5, elution flow rate 2.3 ml min(-1), time of elution 60s, eluent composition, 0.4 mol l(-1) HNO(3). Under these conditions, the preconcentration factor obtained was 36, and the detection limit achieved was 8.4 ng ml(-1) in water samples and 0.84 microg g(-1) in biological material. The maximum adsorption capacity of DAPPS to Cu(2+) was 0.49 mmol g(-1) (31.1 mg g(-1)) obtained in a batch system. The recovery of copper in the water samples ranged from 96.9 to 102.4% and in the biological materials ranged from 97.0 to 102.6%.  相似文献   

7.
This paper reports the development of a new strategy for low-level determination of copper in water samples by using a flow-injection system coupled to solid-phase extraction (SPE) using flame atomic absorption spectrometry (F AAS) as detector. In order to preconcentrate copper from samples, a minicolumn packed with a styrene-divinylbenzene resin functionalized with (S)-2-[hydroxy-bis-(4-vinyl-phenyl)-methyl]-pyrrolidine-1-carboxylic acid ethyl ester was used and the synthesis procedure is described. System operation is based on the on-line retention of Cu(II) ions at pH 9.0 ± 0.2 in a such minicolumn with posterior analyte elution with 2 mol l−1 HCl directly to the F AAS nebulizer. The influence of several chemical (sample pH, buffer concentration, HCl eluent concentration and effect of the ionic strength) and flow (sample and eluent flow rates and preconcentration time) variables that could affect the performance of this system were investigated as well as the possible interferents. At optimized conditions, for 2 min of preconcentration time (13.2 ml of sample volume), the system achieved a detection limit of 1.1 μg l−1, a R.S.D. 1% at 20 μg g l−1 and an analytical throughput of 25 h−1, whereas for 4 min of preconcentration time (26.4 ml of sample volume), a detection limit of 0.93 μg l−1, a R.S.D. 5.3% at 5 μg l−1 and a sampling frequency of 13 h−1 were reported.  相似文献   

8.
A flow-injection system with a Chelite-S(R) cationic resin packed minicolumn is proposed for the determination of trace levels of mercury in agroindustrial samples by cold vapor atomic absorption spectrometry. Improved sensitivity and selectivity are attained since mercuric ions are on-line concentrated whereas other potential interferents are discarded. With on-line reductive elution procedure, concentrated hydrochloric acid could be replaced by 10% w/v SnCl(2), in 6 M HCl as eluent. The reversed-intermittent stream either carries the atomic mercury to the flow cell in the forward direction or removes the residue from reactor/gas-liquid separator to a discarding flask in the opposite direction. Concentration and volume of reagent, acidity, flow rates, commutation times and potential interfering species were investigated. For 120 s preconcentration time, the proposed system handles about 25 samples h(-1) (50.0-500 ng l(-1)), consuming about 10 ml sample and 5 mg SnCl(2) per determination. The detection limit is 0.8 ng l(-1) and the relative standard deviation (RSD) (n=12) of a 76.7 ng l(-1) sample is about 5%. Results are in agreement with certified value of standard materials at 95% confidence level and good recoveries (97-128%) of spiked samples were found.  相似文献   

9.
A rapid separation and preconcentration method was developed for the determination of trace metals Cu, Zn, Cd, and Pb in seawater using a minicolumn packed with thiol cotton fiber (TCF) coupled with inductively coupled plasma mass spectrometry (ICP-MS). Preconcentration parameters, such as seawater sample volume and flow rate and eluent hydrochloric acid concentration, volume and flow rate, were optimized. Under the optimized conditions, trace metals Cu, Zn, Cd, and Pb in seawater can be determined with no interference from saline matrices. When a sample volume of 1500 ml and a sample flow rate of 15 ml min(-1) were used, the preconcentration factor of 1500 and RSD value of <7% at ng ml(-1) were achieved. The accuracy of the recommended method was verified by the analysis of certified reference materials.  相似文献   

10.
Lima R  Leandro KC  Santelli RE 《Talanta》1996,43(6):977-983
A procedure for the preconcentration and determination of lead in vegetable and biological samples was developed in the continuous mode coupled to a flame atomic absorption spectrometer. Lead is quantitatively preconcentrated in acetic buffer as its diethyldithiocarbamate chelate onto a C-18 minicolumn, placed in the loop of a proportional injector, eluted by a stream of methyl isobutyl ketone and introduced directly into the nebuliser. A detection limit of 3 microg 1(-1) is obtained using a time-based technique for 2 min preconcentration and an RSD of 3.8% was readily achieved for three measurements of 25 microg Pb 1(-1). The sample throughput is 24 h(-1). Using preconcentration times of 10 min an enrichment factor of 189 can be obtained. The continuous flow system was used for some reference sample analysis and the obtained results reveal that the methodology can be easily applied for vegetable and biological sample analysis.  相似文献   

11.
A simple field sampling-preconcentration method for zinc determination in seawater is described. Seawater was collected in situ by pumping it through a minicolumn packed with a chelating resin (Chelite P) connected to a field flow preconcentration system (FFPS). These packed minicolumns retain the dissolved zinc, and once are loaded with the analyte, they are returned to the laboratory where they are sequentially inserted into a flow injection system for on-line zinc elution with diluted hydrochloric acid and flame atomic absorption spectrometric detection. A factorial design has been used to optimize the FFPS and the flow injection elution process. The proposed method has a linear calibration range from 0.07 to at least 9.4 microg L(-1) of zinc, with a detection limit of 0.02 microg L(-1) and a throughput of 26 samples h(-1). Validation was carried out against certified reference water samples. This procedure has been successfully applied to the determination of Zn in seawater samples from Galicia (Spain).  相似文献   

12.
An on-line system for preconcentration and determination of copper at μg l−1 level by flame atomic absorption spectrometry (FAAS) is proposed. Amberlite XAD-2 functionalized with 3,4-dihydroxybenzoic acid packed in a minicolumn was used as sorbent. Copper(II) ions were sorbed in the minicolumn, from which it could be eluted by hydrochloric acid solution directly to the nebulizer-burner system of the FAAS. Eluent solution was carried by water at a flow rate of 5.00 ml min−1. Signals were measured as peak height by using an instrument software. Achieved sampling rate was 27 samples per hour. Analytical parameters were evaluated and the results demonstrated that copper can be determined, with acetate buffer to adjust the sample pH at 6.0, preconcentration time of 120 s and a sample flow rate of 6.50 ml min−1. The desorption was carried out with 30 μl of a 1.0 mol l−1 hydrochloric acid solution. An enrichment factor of 33 in 13.00 ml of sample (120 s preconcentration time) was achieved by using the time-based technique. The detection limit (DL) (3 s) was 0.27 μg l−1 and the precision (assessed as the relative standard deviation) reached values of 5.7-1.1% in copper solutions of 5.00 to 50.00 μg l−1 concentration, respectively. The accuracy of procedure was confirmed by copper determination in certified reference materials. Recoveries of spike additions (1.0 or 2.0 μg g−1) to food samples were quantitative (90.0-110.0%). These results proved also that the procedure is not affected by matrix interference and can be applied satisfactorily for copper determination in rice flour and starch samples.  相似文献   

13.
Iglesias M  Anticó E  Salvadó V 《Talanta》2003,59(4):651-657
A preconcentration method is developed for the on-line determination of palladium in complex matrices with flame atomic absorption spectrometry (FAAS). The flow system comprised of a minicolumn filled with polyamine Metalfix-Chelamine resin which is highly selective for Pt(IV), Au(III) and Pd(II). Best preconcentration conditions are established by testing different resin quantities, sample and eluent solution volumes, and adsorption and elution steps flow rates. Sample volumes of 4.7 ml of palladium solutions resulted in an enrichment factor of twenty at the optimum hydrodynamic conditions. This value can be increased by injecting larger volumes of sample solution. The method is sensitive, easy to operate and permitted the determination of sub-mg l−1 levels of palladium with a detection limit of 0.009 mg l−1. The resin was used up to 60 times in consecutive retention-elution cycles without any appreciable deterioration in its performance. The applicability of this method was tested by determining the palladium content in synthetic geological samples as well as in the pellet-type used car catalyst reference material.  相似文献   

14.
An on-line zinc preconcentration and determination system implemented with inductively coupled plasma atomic emission spectrometry (ICP-AES) associated with flow injection (FI) was studied. The zinc was retained as zinc-2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (Zn-(5-Br-PADAP)) complex at pH 9.2. The zinc complex was removed from the knotted reactor (KR) with 30% v/v nitric acid. An enrichment factor of 42 was obtained for the KR system with respect to ICP-AES using pneumatic nebulization. The detection limit for the preconcentration of 10 mL of aqueous solution was 0.09 microg/L. The precision for 10 replicate determinations at the 5 microg/L Zn level was 2.3% relative standard deviation (RSD), calculated with the peak heights obtained. The calibration graph using the preconcentration system for zinc was linear with a correlation coefficient of 0.9997 at levels near the detection limits up to at least 100 microg/L. The method was succesfully applied to the determination of zinc in river water samples.  相似文献   

15.
An on-line zinc preconcentration and determination system implemented with inductively coupled plasma optical emission spectrometry (ICP-OES) was developed. The zinc was precipitated and retained on a minicolumn filled with ethyl vinyl acetate (EVA) at pH 9.0, without using any complexing reagent. The zinc ions were eluted from the minicolumn with 10% (v/v) hydrochloric acid. Experimental conditions including pH and sample loading and eluting variables were evaluated and established.An enrichment factor (EF) of 44 was obtained for Zn2+ with a preconcentration time of 120 s. Under the optimal conditions, the value of the limit of detection (3σ) for the preconcentration of 10 mL of sample was 0.08 μg L− 1. The sampling frequency was about 24 h− 1. The precision for six replicate determinations (repeatability conditions) at 50 μg L− 1 Zn level was 3.94% relative deviation standard (RSD), calculated from the peak heights obtained. The methodology was successfully applied to the determination of zinc in tap water samples and in a certified VKI reference material QC Metal LL1 DHI (Water & Environment) Denmark.  相似文献   

16.
An on-line preconcentration procedure for the determination of bismuth by flame atomic absorption spectrometry (FAAS) has been described. Lewatit TP-207 chelating resin, including iminodiacetate group, packed in a minicolumn was used as adsorbent material. Bi(III) was sorbed on the chelating resin, from which it could be eluted with 3 mol L−1 HNO3 and then introduced directly to the nebulizer-burner system of FAAS. Best preconcentration conditions were established by testing different resin quantities, acidity of sample, types of eluent, sample and eluent solution volumes, adsorption and elution flow rates, and effect of interfering ions. The detection limit of the method was 2.75 μg L−1 while the relative standard deviation was 3.0% for 0.4 μg mL−1 Bi(III) concentration. The developed method has been applied successfully to the determination of bismuth in pharmaceutical cream, standard reference materials and various natural water samples with satisfactory results.  相似文献   

17.
The use of ram horn powder (RHP) as a new sorbent for the preconcentration of copper(II) was proposed. The procedure is based on the adsorption of copper(II) ions as 1-nitroso-2-naphthol-3,6-disulfonic acid chelate onto the minicolumn packed with RHP followed by the elution with 5 mL 1 M HCl and determination by flame atomic absorption spectrometry (FAAS). Analytical variables such as pH, eluent type, flow rate, and sample volume were optimized, and analytical parameters such as accuracy and limit of detection were studied. The optimum pH of the sample solution was found to be in a range of 4–8. The enrichment factor when using a sample volume of 500 mL was 100. The capacity of the sorbent was found to be 1.7 mg/g. The limit of detection for copper(II) was 0.42 μg/L. The accuracy of the method was confirmed by analyzing the lead base alloy and aluminum base alloy (NBS SRM 53e, NBS SRM 85b). The results demonstrated good agreement with the certified values. The procedure was applied to the determination of copper in aluminum foil and different waters, such as tap water, lake water, dam water, and synthetic seawater samples. The text was submitted by the authors in English.  相似文献   

18.
《Analytica chimica acta》2003,481(2):283-290
In the present paper, an on-line system for preconcentration and determination of zinc by Flame Atomic Absorption Spectrometry (FAAS) is proposed. It is based in the sorption of zinc(II) ions on a minicolumn packed with polyurethane foam loaded with 2-[2′-(6-methyl-benzothiazolylazo)]-4-bromophenol (Me-BTABr) reagent. Chemical and flow variables as pH effect, sample flow rate and eluent concentration were optimized using univariate methodology. The results demonstrated that zinc can determinate using the sample pH in the range of 6.5-9.2, sample flow rate of 6.0 ml min−1, and the elution step using 0.10 mol l−1 hydrochloric acid solution at flow rate of 5.5 ml min−1. In these conditions, an enrichment factor of 23 and a sampling rate of 48 samples per hour were achieved. The detection limit (DL, 3σ) as IUPAC recommendation was 0.37 μg l−1 and the precision (assessed as the relative standard deviation, R.S.D.) reached values of 5.9-1.8% in zinc solutions of 1.0-10.0 μg l−1 concentration, respectively. The method was successfully applied to the determination of trace amounts of zinc in natural water samples from Salvador (Brazil).  相似文献   

19.
1-(2-pryidylazo)-2-naphthol (PAN) immobilized on sodium dodecyl sulfate-coated nano alumina was developed for the preconcentration and determination of metal cations Co (II) from environmental and food samples. The research results displayed that adsorbent has the highest adsorption capacity for Co (II) in this system. Desorption by elution of the adsorbent with 2.0?ml of a mixture of nitric acid and ethanol was carried out. After phase separation, the enriched analyte in the final solution is determined by flame atomic absorption spectrometry (FAAS) by using a micro sample introduction system. Analytical influencing parameters including pH value, amount of sorbent, equilibrium time, sample volume, volume and concentration of eluent were examined. The effect of common matrix ions has also been investigated and it was found that they had no influence on cobalt preconcentration. Under the optimum experimental conditions, the maximum capacity of sorbent was obtained as 20?mg?g?1. The preconcentration factor and limit of detection were found to be 250 and 0.15?µg?L?1, respectively. This method showed good precision with the relative standard deviation (RSD) of 2.4% and 2.1% in concentrations of 20 and 50?µg?L?1, respectively. The accuracy of the method was evaluated by comparison of results with those obtained by electrothermal atomic absorption spectrometry. This method was successfully applied for preconcentration and determination of Co (II) in environmental and food samples.  相似文献   

20.
A simple and sensitive flow-injection on-line separation and preconcentration system coupled to hydride generation atomic fluorescence spectrometry (HG-AFS) was developed for ultra-trace lead determination in water, wine, and rice samples, with the salient advantages of its minimization of transition-metal interferences and tolerance to an ethanol matrix. A lead hydroxide precipitate was achieved by the on-line merging of a sample and an ammonium buffer solution and collected onto the inner walls of a knotted reactor (KR). Removal of the residual solution from KR was achieved by air flow, and dissolution of the precipitate was carried out by using 0.2 mol l(-1) HCl. With a sample consumption of 11.7 ml, an enhancement factor of 16 was obtained at a sample throughput of 30 h(-1). The limit of detection (3s) was 16 ng l(-1) and the precision (RSD) for 1.0 microg l(-1) Pb was 3.4%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号