首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A sensitive method is described for the measurement of remoxipride in human plasma and urine. Remoxipride and its internal standard are extracted from plasma or urine at pH 12 with a mixture of hexane and methyl tert.-butyl ether. After washing the organic phase with base, the compounds are extracted into acid and analyzed on a C18 column with ultraviolet detection at 214 nm. The mobile phase is composed of acetonitrile and aqueous buffer (sodium perchlorate and phosphoric acid, pH 1.7). The limits of reliable quantitation for remoxipride are 12.5 and 50 ng/ml for plasma and urine, respectively. The run times are 6 min for plasma and 3 min for urine. The method has been successfully used to assay remoxipride clinical study samples. This mobile phase has also been successfully applied to the analysis of other basic drugs such as cimetidine, codeine, diltiazem and quinidine with minor modifications.  相似文献   

2.
A reversed-phase high-performance liquid chromatographic assay with ultraviolet detection at 243 nm has been developed for the quantitative determination of methylprednisolone (MP) and methylprednisolone 21-[8-[methyl-(2-sulfoethyl)amino]-8-oxooctanoate] sodium salt (MPSO) in human urine following therapeutic doses in humans. The assay procedure involves stabilization of urine samples by addition of disodium ethylenediaminetetraacetic acid (Na2EDTA) and ion-pair extractions of MPSO using tetraethylammonium chloride (TEACl) as the counter ion. After extracting both drugs and internal standard into chloroform, the extract was evaporated to dryness under nitrogen. The resulting residue was reconstituted in 200-500 microliters of mobile phase and chromatographed on an IBM C18 reversed-phase column (5 microns). The mobile phase was a mixture of water-acetonitrile-isopropanol (71.2:18.8:10.0, v/v) containing 75 microliters of 0.1 M hydrochloric acid and 0.450 g of TEACl per liter. Propyl p-hydroxybenzoate was used as an internal standard. The extraction efficiencies of MP and MPSO were greater than 90% using the ion-pairing agent TEACl. The chromatographic responses were linear up to about 200 micrograms/ml for MP and 80 micrograms/ml for MPSO and had sufficient precision and accuracy to provide quantitative data from human urine. The assay detection limit was about 8 ng/ml for MP and 25 ng/ml for MPSO in human urine. Stability studies in urine indicated that without Na2EDTA stabilization and at room temperature, rapid degradation of MPSO occurred in urine. Addition of EDTA to the urine specimen and storage at -70 degrees C increased the stability of MPSO, and little or no degradation was observed in urine stored for more than 60 days. The method has been used in the simultaneous determination of MP and MPSO in urine specimens obtained from a single-dose tolerance study of MPSO in normal male volunteers.  相似文献   

3.
A sensitive and selective high-performance liquid chromatography method has been developed for the determination of the new monocyclic beta-lactam antibiotic carumonam in plasma and urine. The method for plasma involves protein precipitation with acetonitrile and removal of lipids with dichloromethane; urine is diluted with buffer. Separation and quantification are achieved using a mobile phase based on either ion-suppression or ion-pair chromatography on a reversed-phase column with UV detection. The limit of determination is 0.5 micrograms/ml plasma, using a 0.5-ml specimen, and 25 micrograms/ml urine, using a 50-microliter specimen. The inter-assay reproducibility is generally better than 4% when an internal standard is used. Since beta-lactam antibiotics may degrade on storage, close attention must be paid to the stability of these drugs in biological fluids; novel measures to prevent degradation on storage are described. The assay has been successfully applied to the analysis of several thousand samples from pharmacokinetic studies, including a study involving patients with impaired renal function.  相似文献   

4.
A high-performance liquid chromatographic method with column switching has been developed for the simultaneous determination of cefamandole and cefamandole nafate in plasma and urine. The plasma and urine samples were injected onto a precolumn packed with Corasil RP C18 (37-50 microns) after simple dilution with an internal standard solution in 0.05 M phosphoric acid. Polar plasma and urine components were washed out using 0.05 M phosphoric acid. After valve switching, the concentrated drugs were desorbed in back-flush mode and separated by a reversed-phase C8 column with methanol-5 mM tetrabutylammonium bromide (45:55, v/v) as the mobile phase. The method showed excellent precision with good sensitivity and speed, and a detection limit of 0.5 microgram/ml. The total analysis time per sample was less than 30 min, and the mean coefficients of variation for intra- and inter-assay were both less than 4.9%. The method has been successfully applied to plasma and urine samples for human volunteers after intravenous injection of cefamandole nafate.  相似文献   

5.
The development of a method for the determination of the antineoplastic vinca alkaloids vinblastine and vindesine in biological samples is described. The selectivity of the assay is high owing to the use of solid-phase extraction on a cyanopropyl extraction column prior to isocratic chromatography on unmodified silica gel with fluorescence detection. The influence of acetonitrile concentration and mobile phase pH on the capacity factors of the drugs was studied in order to optimize the separation between the drugs and endogenous components. The effect of varying the type and concentration of competing cations in the mobile phase was also examined. The limit of determination (signal-to-noise ratio = 3) for vinblastine is 0.5 ng/ml in plasma and urine and for vindesine 2.5 ng/ml. The assay is suitable for determining the concentrations of both compounds in plasma and urine samples from patients.  相似文献   

6.
A sensitive and selective high-performance liquid chromatographic method for determination of intact glipizide in human plasma or urine has been developed. The plasma and urine samples were acid-buffered, before tolbutamide was added as internal standard. The samples were extracted with benzene, and the organic layer was evaporated to dryness. The residue was dissolved in equilibrated mobile phase (acetonitrile-0.01 M phosphate buffer pH 3.5, 35:65), and an aliquot of 20 microliters was chromatographed on a Spherisorb ODS reversed-phase column. Quantitation was achieved by monitoring the ultraviolet absorbance at 275 nm. The response was linear (0-1000 ng/ml) and the detection limit was 5-10 ng/ml in plasma or urine. The within-assay variation was less than or equal to 10%. No interferences from metabolites or endogenous constituents were observed. The utility of the assay was demonstrated by determining glipizide in samples from a diabetic subject receiving a therapeutic dose of 5 mg of the drug.  相似文献   

7.
A high‐performance liquid chromatography tandem–mass spectrometry (HPLC‐MS/MS) method has been developed to analyze anthocyanins in urine and plasma to further understand their absorption, distribution, metabolism and excretion. The method employed a Synergi RP‐Max column (250 × 4.6 mm, 4 μm) and an API 4000 mass spectrometer. A gradient elution system consisted of mobile phase A (water–1% formic acid) and mobile phase B (acetonitrile) with a flow rate of 0.60 mL/min. The gradient was initiated at 5% B, increased to 21% B at 20 min, and then increased to 40% B at 35 min. The analysis of anthocyanins presents a challenge because of the poor stability of anthocyanins during sample preparation, especially during solvent evaporation. In this method, the degradation of anthocyanins was minimized using protein precipitation and dilute‐and‐shoot and sample preparation methods for plasma and urine, respectively. No interferences were observed from endogenous compounds. The method has been used to analyze anthocyanin concentrations in urine and plasma samples from volunteers administered saskatoon berries. Cyanidin‐3‐galactoside, cyanidin‐3‐glucoside, cyanidin‐3‐arabinoside, cyanidin‐3‐xyloside and quercetin‐3‐galactoside, the five major flavonoid components in saskatoon berries, were identified in plasma and urine samples.  相似文献   

8.
An assay for the selective quantification of pseudoephedrine in human plasma and urine was developed using high-performance liquid chromatography with UV detection at 205 nm. Analyte and internal standard were extracted from alkaline plasma or urine into a mixture of n-hexane and diethyl ether, and the organic phase was back-extracted into dilute acid. The chromatographic system comprises microparticulate cyanopropyl-silica as stationary phase and a ternary solvent mixture with ion-pair reagents as mobile phase. Using 0.25 ml plasma, the lower limit of quantification was 25 ng/ml with excellent linearity up to 1000 ng/ml. In urine, the calibration ranged from 2.5 to 100 micrograms/ml. The selectivity of the method was demonstrated for several pharmaceuticals with similar structures. The validated method was applied to a pharmacokinetic study with a single oral dose of 100 mg of pseudoephedrine in two galenic formulations. Precision and accuracy data of the assay and calculated pharmacokinetic parameters are presented.  相似文献   

9.
A simple and sensitive high-performance liquid chromatographic method for the simultaneous assay of amiodarone and desethylamiodarone in plasma, urine and tissues has been developed. The method for plasma samples and tissue samples after homogenizing with 50% ethanol, involves deproteinization with acetonitrile containing the internal standard followed by centrifugation and direct injection of the supernatant into the liquid chromatograph. The method for urine specimens includes extraction with a diisopropyl ether-acetonitrile (95:5, v/v) mixture at pH 7.0 using disposable Clin-Elut 1003 columns, followed by evaporation of the eluate, reconstitution of the residue in methanol-acetonitrile (1:2, v/v) mixture and injection into the chromatograph. Separation was obtained using a Radial-Pak C18 column operating in combination with a radial compression separation unit and a methanol-25% ammonia (99.3:0.7, v/v) mobile phase. A wavelength of 242 nm was used to monitor amiodarone, desethylamiodarone and the internal standard. The influence of the ammonia concentration in the mobile phase on the capacity factors of amiodarone, desethylamiodarone and two other potential metabolites, monoiodoamiodarone (L6355) and desiodoamiodarone (L3937) were investigated. Endogenous substances or a variety of drugs concomitantly used in amiodarone therapy did not interfere with the assay. The limit of sensitivity of the assay was 0.025 micrograms/ml with a precision of +/- 17%. The inter- and intra-day coefficient of variation for replicate analyses of spiked plasma samples was less than 6%. This method has been demonstrated to be suitable for pharmacokinetic and metabolism studies of amiodarone in man.  相似文献   

10.
High-performance liquid chromatographic (HPLC) methods using ultraviolet (UV) detection have been developed for the assay of the antibiotic imipenem (N-formimidoyl thienamycin) in human plasma and urine. A reversed-phase analytical column is employed in the plasma assay method and a cation-exchange column is used in the urine assay method. Both methods use borate buffer in the mobile phase. The method of preparation of human fluid samples for HPLC injection has been optimized with respect to the stability of imipenem in aqueous buffers, in morpholine buffer--ethylene glycol stabilizer, and in urine and plasma. Preparation of the samples before injection into the HPLC systems involves deproteination/filtration of the plasma/urine samples. The open lactam metabolite and the coadministered dehydropeptidase inhibitor, cilastatin sodium, do not interfere with the 313-nm detection of imipenem in either the plasma or the urine assay. Thienamycin, the precursor of imipenem and an impurity in imipenem formulations, is separated from the drug using both of these methods. Concentrations generated from the HPLC analysis of plasma and urine samples from two healthy volunteers compare favorably with results using a microbiological assay method. Correlation of the two methods gives r greater than or equal to 0.990 for both fluids.  相似文献   

11.
A high-performance liquid chromatographic (HPLC) method with electrochemical detection for the determination of oxilofrine [1-(4-hydroxyphenyl)-2-methylaminopropanol] in human plasma and urine (before and after cleavage of the metabolic conjugates) is described. Isolation from biological fluids is performed batchwise by weak acid cation exchange. Separation of plasma and urine components is achieved on a reversed-phase C18 column as an ion pair with heptanesulphonic acid. For amperometric detection the potential of the electrode was set at 0.95 V versus an Ag/AgCl reference electrode. The detection limit for oxilofrine in plasma is 1 ng/ml and in urine 12.5 ng/ml at a signal-to-noise ratio of 2.0 using 1.0 ml of plasma and 0.02 ml of urine. The method was compared with a gas chromatographic-mass spectrometric method and showed a good concordance for plasma (r = 0.996) and urine (r = 0.994). With the HPLC method it is also possible to determine related sympathomimetic drugs, e.g., etilefrine, norefenefrine or octopamine, after a slight modification of the mobile phase.  相似文献   

12.
A high-performance liquid chromatographic method is described for the analysis of the anti-bacterial agent cefotaxime and desacetylcefotaxime in physiological fluids. Plasma or serum samples were mixed with chloroform--acetone to remove proteins and most lipid material. The aqueous phase was then freeze-dried, reconstituted in mobile phase and chromatographed on a reversed-phase column using UV detection at 262 nm. Urine was analysed directly after centrifugation to remove particulate matter. The detection limit was 0.5--1.0 micrograms/ml for serum and 5 micrograms/ml for urine. The method has been applied to the analyses of cefotaxime and desacetylcefotaxime in plasma, serum, urine, cerebrospinal fluid, saliva, and pus from infected wound secretions. Two additional metabolites, which are lactones in which the beta-lactam ring has been opened, could be separated by this method.  相似文献   

13.
A sensitive reversed-phase high-performance liquid chromatographic (HPLC) technique with ultraviolet detection has been developed to determine the concentration of BRB-I-28 (I), a novel antiarrhythmic agent, in dog plasma and urine. The mobile phase was acetonitrile-methanol-37.5 mM phosphate buffer, pH 6.8-triethylamine (50:50:75:0.1, v/v). The compound was extracted from dog plasma and urine with chloroform after alkalinization with sodium hydroxide. The extraction recovery was 83% from plasma and 84% from urine. Good linearity (r > 0.996) was observed throughout the ranges 0.1-12.0 micrograms/ml (plasma) and 0.1-8.0 micrograms/ml (urine). Intra- and inter-assay variabilities were less than 4%. The lower limit of quantitation was 0.08 microgram/ml in either plasma or urine. HPLC analysis of plasma and urine samples from a dog treated with I has demonstrated that the method was accurate and reproducible.  相似文献   

14.
The feasibility of directly assaying drugs in physiological fluids using on-line preconcentration and microbore high-performance liquid chromatography has been demonstrated. The untreated sample is injected onto a hydrophobic pre-column, using micellar sodium dodecyl sulfate (SDS) in the case of serum or phosphate buffer in the case of urine, as the load mobile phase. This traps the components of interest which are then backflushed onto a microbore analytical column using a stronger mobile phase. This procedure was then applied to diazepam in serum and phenobarbital in urine. Recovery was linear and quantitative over the range 30-3000 ng/ml for diazepam in serum and 2-200 micrograms/ml for phenobarbital in urine. The diazepam method was specific against caffeine and the three major metabolites of diazepam: oxazepam, temazepam, and nordiazepam. The effects of varying pre-column dimensions, pre-column loading time, and SDS concentration volume were evaluated.  相似文献   

15.
A highly sensitive, rapid assay method has been developed and validated for the estimation of JI-101 in human plasma and urine using LC-MS/MS-ESI in the positive-ion mode. The assay procedure involves extraction of JI-101 and alfuzosin (internal standard, IS) from human plasma/urine with a solid-phase extraction process. Chromatographic resolution was achieved on two Zorbax SB-C(18) columns connected in series with a PEEK coupler using an isocratic mobile phase comprising acetonitrile-0.1% formic acid in water (70:30, v/v). The total run time was 2.0 min. The MS/MS ion transitions monitored were 466.20 → 265.10 for JI-101 and 390.40 → 156.10 for IS. The method was subjected to rigorous validation procedures to cover the following: selectivity, sensitivity, matrix effect, recovery, precision, accuracy, stability and dilution effect. In both matrices the lower limit of quantitation was 10.0 ng/mL and the linearity range extended from ~10.0 to 1508 ng/mL in plasma or urine. The intra- and inter-day precisions were in the ranges 1.57-14.5 and 6.02-12.4% in plasma and 0.97-15.7 and 8.66-10.2% in urine. This method has been successfully applied for the characterization of JI-101 pharmacokinetics in cancer patients.  相似文献   

16.
A selective and sensitive high-performance liquid chromatographic method for determination of intact glibenclamide in human plasma or urine has been developed. With glibornuride as internal standard, acid-buffered plasma or urine was extracted with benzene. The organic layer was evaporated and the residue was dissolved in equilibrated mobile phase (acetonitrile-phosphate buffer 0.01 M pH 3.5, 50:50). An aliquot of 20 microliters was chromatographed on a Spherisorb ODS reversed-phase column, and quantitation was achieved by monitoring the ultraviolet absorbance at 225 nm. The response was linear (0-1000 ng/ml) and the detection limit was 5-10 ng/ml in plasma or urine. The within-assay variation was less than or equal to 10%. No interferences from metabolites or endogenous constituents could be noted. The utility of the method was demonstrated by analysing glibenclamide in samples from diabetic subjects on therapeutic doses of the drug.  相似文献   

17.
A liquid chromatographic method is described for separating and determining vinblastine, vincristine and vindesine in plasma and urine. The drugs are extracted from the biological material using an ion-pair extraction, with sodium octylsulphate as counter-ion at pH 3. The extracts are injected on a reversed-phase system with a cyano column as stationary phase and a mobile phase composed of acetonitrile-phosphate buffer, pH 3 (65:35, vol. %). Stability studies are carried out for stock solutions of the drugs in water at different temperatures and pH values. The stability of these compounds in plasma is also investigated in the presence of an antioxidant. The method is applied to determine drug levels of vindesine and vinblastine in preliminary pharmacokinetic studies, using vincristine as the internal standard.  相似文献   

18.
A high-performance liquid chromatographic method with electrochemical detection is described for quantification of pamaquine, primaquine and carboxy primaquine in calf plasma. After the proteins had been precipitated with acetonitrile, the drugs were separated on a 5-microns C18-modified polymer gel column with an isocratic mobile phase. The detection limit was 0.01 microgram/ml in plasma for all three compounds. The applicability of the method in pharmacokinetic studies was demonstrated by determining the plasma concentrations of the three substances in calves administered a single dose of pamaquine or primaquine.  相似文献   

19.
A reversed-phase high-performance liquid chromatographic (HPLC) method has been developed for the determination of neomycin in plasma and urine. The plasma was deproteinated with trichloroacetic acid and centrifuged. The supernatant was mixed with ion-pair concentrate and centrifuged again. The resultant supernatant was analyzed by HPLC. Urine was centrifuged to remove debris, if any, mixed with ion-pair concentrate and analyzed directly by HPLC. The HPLC conditions consisted of an ion-pairing mobile phase, a reversed-phase column, post-column derivatization with o-phthalaldehyde (OPA) reagent and fluorescence detection. The overall average recovery of neomycin was 97 and 113% from plasma spiked at 0.25-1.0 micrograms/ml, using standard curves prepared in plasma extract and in water, respectively, and 94% for urine spiked at 1-10 micrograms/ml using a standard curve prepared in water. The method was used to detect neomycin in plasma and urine obtained from animals injected intramuscularly with neomycin. Various pharmacokinetic parameters of neomycin were also determined from its profile of plasma concentration versus time.  相似文献   

20.
Abstract

A high pressure Liquid chromatographic analysis of phenylpropano Lamine in plasma and urine by post-column derivatzaition with o-phthalaldehyde is described. Plasma samples are extracted with methylene chloride under alkaline conditions. Urine is diluted with mobile phase without extraction. Using fluorescence detection, the method is sufficiently sensitive (2 ng/ml in 0.5 ml of plasma and 0.5 mcg/ml in 0.2 ml of urine) so that phenylpropano lamine concentrations in plasma or urine may be measured for up to 24 hours following a 75 mg oral dose. Coefficients of variation for inter-day and intra-day precision are less than 10%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号