1.
In this work, open-tubular capillary electrochromatography (OT-CEC) method with bare gold nanoparticles (GNPs)-based stationary phase has been developed and applied for separation of tryptic peptide fragments of native and glycated proteins, bovine serum albumin (BSA), and human transferrin (HTF). The GNPs-based stationary phase was prepared by immobilization of bare GNPs, freshly reduced from tetrachloroaurate(III) ions by citrate reduction, on the sol-gel pretreated inner wall of the fused silica capillary. The separation efficiency, peak capacity, and peptide recovery of this open-tubular capillary column were investigated by varying the experimental parameters such as type and concentration of the buffering constituent and pH of the background electrolyte (BGE), temperature, and separation voltage. The best separations of the above tryptic peptides were achieved in the BGE composed of aqueous 100 mmol/L sodium phosphate buffer, pH 2.5, at separation voltage 10 kV per 47-cm long, 50 μm inside diameter capillary thermostated at 25°C. OT-CEC with bare GNPs stationary phase is shown to be a suitable technique for separation of complex peptide mixtures arising from tryptic digestion of native and glycated BSA and HTF, and for investigation of glycation (nonenzymatic glycosylation) of these proteins.  相似文献   

2.
An open tubular molecule imprinted polymer (OT‐MIP) capillary column has been prepared for chiral separation of ofloxacin enantiomers in CEC. The S‐ofloxacin imprinted OT column was fabricated by thermally initiated non‐covalent polymerization procedure inside a pretreated and silanized fused silica capillary. The template molecule was incorporated with methacrylic acid (MAA), ethylene glycol dimethacrylate (EDMA) and 4‐styrenesulfonic acid (4‐SSA) and dissolved in a porogen mixture of ACN/2‐propanol (9:1). The separation efficiency of the 4‐SSA MIP column was found quite better than that of the MIP column without 4‐SSA. It has been demonstrated that our OT‐MIP column can separate ofloxacin enantiomers with excellent chiral separation efficiency after tuning the various chromatographic conditions. The optimized chromatographic eluent was 85:15, v/v%, ACN/60 mM sodium acetate at pH 7. The separation efficiency and selectivity of chiral separation of this study were far better than those obtained by previous methods for chiral separation of R‐ and S‐ofloxacin.  相似文献   

3.
4.
A variety of strategies have been developed to adsorb and separate light hydrocarbons in metal–organic frameworks. Here, we present a new approach in which the pores of a framework are lined with four different C3 sidechains that feature various degrees of branching and saturation. These pendant groups, which essentially mimic a low‐density solvent with restricted degrees of freedom, offer tunable control of dispersive host–guest interactions. The performance of a series of frameworks of the type Zn2(fu‐bdc)2(dabco) (fu‐bdc2?=functionalized 1,4‐benzenedicarboxylate; dabco=1,4‐diazabicyclo[2.2.2]octane), which feature a pillared layer structure, were investigated for the adsorption and separation of methane, ethane, ethylene, and acetylene. The four frameworks exhibit low methane uptake, whereas C2 hydrocarbon uptake is substantially higher as a result of the enhanced interaction of these molecules with the ligand sidechains. Most significantly, the adsorption quantities and selectivity were found to depend strongly upon the type of sidechains attached to the framework scaffold.  相似文献   

5.
Zhu Y  Zhou C  Qin S  Ren Z  Zhang L  Fu H  Zhang W 《Electrophoresis》2012,33(2):340-347
A novel open‐tubular capillary electrochromatography (OT‐CEC) with modified core/shell magnetic nanoparticles coating as stationary phase was introduced using external magnetic force to fix magnetic nanoparticles. The magnetic nanoparticles coating inside the capillary columns could be easily regenerated by removing and re‐applying the external magnetic field. Magnetic field intensity, concentration and flow rate of nanoparticles suspension were investigated to achieve simple and stable preparation. Mixture of five organic acids was used as the marker sample to evaluate the OT‐CEC system, and the relative column efficiency of anthranilic acid reaches 220 000 plates/m. The excellent within‐column and between‐column repeatability has been testified with the RSDs of retention time of less than 1.51 and 5.29%, respectively. The aqueous extract of rhizoma gastrodiae was analyzed by the OT‐CEC system, and 23 peaks were eluted in 30 min. Compared with conventional open‐tubular capillary column, this new system shows faster separation speed and higher column efficiency from the larger surface area of nanoparticles. It has great potential in the method development for the analysis of complex samples, since magnetic coating can effectively prolong the column life by expediently replacing stationary phase to eliminate the pollution or irreversible adsorption.  相似文献   

6.
A very recent epidemiological study provided strong support for nobiletin (NOB) as a potential candidate chemopreventive agent against cancer. From the pharmacology point of view, drug–protein interactions are determining factors in therapeutic, pharmacodynamic and toxicological drug properties. In this work, for the first time, detection of NOB at near‐physiological conditions was accomplished by means of capillary electrophoresis–frontal analysis (CE‐FA), and then the binding constants of NOB with bovine serum albumin (BSA) at the same conditions were determined. Complexation of NOB–BSA led to a decrease of the height for free NOB with increasing concentration of BSA. These results revealed the presence of a single class of binding site on BSA, and provided the binding constant of 103/m , showing the strong affinity of NOB for BSA. Furthermore, circular dichroism spectra showed that, when the molar ratio of NOB to BSA was up to 2:1, NOB did not affect the overall protein conformation significantly and the protein thus retained a native‐like structure. These results may provide important information for preclinical studies of nobiletin in pharmaceutical research. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

7.
A new trimethylamine amination polychloromethyl styrene nanolatex (TMAPL) and TMAPL coated capillary column (ccc‐TMAPL) were successfully prepared. The TMAPL coating was characterized with reversed steady EOF values of ca. ?16.8 × 10?5 cm2 V?1 s?1. It was applied to establish open‐tubular (OT) CEC and field‐amplified sample stacking (FASS) OT‐CEC methods for the determination of bromate in tap water. Compared to OT‐CEC, the LOD with FASS‐OT‐CEC was improved from 80 to 8 ng/mL. The developed FASS‐OT‐CEC method was practically used for the analysis of bromate in tap water samples with recoveries ranging from 93.6 to 103.5%.  相似文献   

8.
《Electrophoresis》2018,39(8):1086-1095
The chiral organic‐inorganic hybrid materials can exhibit a high loading, and the chiral selector nanoparticles can create efficient stationary phases for open‐tubular capillary electrochromatography (OT‐CEC). Hence, a novel protocol for the preparation of an OT column coated with nano‐amylose‐2,3‐bis(3,5‐dimethylphenylcarbamate) (nano‐ABDMPC)‐silica hybrid sol through in situ layer‐by‐layer self‐assembly method was developed for CEC enantioseparation. By controlling the assembly cycle number of nano‐ABDMPC‐silica hybrid sol, a homogeneous, dense and stable coating was successfully prepared, which was confirmed by SEM and elemental analysis. As the main parameter influencing the chiral separating effect, the nano‐ABDMPC bearing 3‐(triethoxysilyl)propyl residues concentration was investigated. The experimental results showed that 10.0 mg/mL nano‐ABDMPC bearing 3‐(triethoxysilyl)propyl residues coated OT capillary column possessed chiral recognition ability toward the six enantiomers (phenylalanine, tyrosine, tryptophan, phenethyl alcohol, 1‐phenyl‐2‐propanol, and Tröger's base) at some of the different conditions tested. Additionally, the coated OT column revealed adequate repeatability concerning run‐to‐run, day‐to‐day and column‐to‐column. These results demonstrated the promising applicability of nano‐ABDMPC‐silica hybrid sol coated OT column in CEC enantioseparations.  相似文献   

9.
A new and simple open‐tubular CEC (OT‐CEC) method with a novel diblock copolymer poly(butyl methacrylate)71‐block‐poly(glycidyl methacrylate)9 as the coating based on its self‐assembled properties has been developed. Compared with the bare capillary, this coating could act as a surfactant and improve the separation efficiency of aromatic amines. Meanwhile, the effects of pH value, buffer concentration, and the copolymer block ratio on the separation efficiencies were investigated in detail. It has been found that the three tested aromatic amines could be baseline separated by the OT‐CEC method with the cooperation of SDS. The proposed OT‐CEC method showed good repeatability with RSDs <3.2% for testing the EOF. Moreover, it was also well validated by satisfactory linearity and favorable recovery, which ensured its successful application in the separation of aromatic amines in nail polish samples. The results revealed the potential applicability of the OT‐CEC method in cosmetic analysis.  相似文献   

10.
To detect the quality of medicinal human albumin by capillary electrophoresis, we produced a fused‐silica capillary coated with thermally cross‐linked poly(vinyl pyrrolidone) to prohibit protein adsorption. This type of capillary was easily obtained by injecting an aqueous poly(vinyl pyrrolidone) solution into a fused‐silica capillary and thermally annealing it at 200°C. Notably, stable and low electro‐osmotic flow was obtained in the poly(vinyl pyrrolidone)‐coated capillary at pH 2.20–9.00, and the separation of a mixture of four basic proteins indicated that the poly(vinyl pyrrolidone)‐coated capillary exhibits excellent repeatability and separation efficiency; moreover, the separation of these four basic proteins could even be achieved at pH 7.00. The protein recovery percentage of human serum albumin in a single‐protein solution and a mixed blood proteins solution was determined to be 97.03 and 95.40% in the poly(vinyl pyrrolidone)50–3 (representing the concentration of the capillary‐injected poly(vinyl pyrrolidone) aqueous solution, 50 mg/mL, and thermal annealing time, 3 h) capillary, respectively. Based on these results, we used the poly(vinyl pyrrolidone)50–3‐coated capillary to quantify the protein content of human albumin, and the results obtained from run to run, day to day and capillary to capillary demonstrated that the coated capillary could be used for quality testing commercially available human albumin.  相似文献   

11.
Parathyroid hormone (PTH) is a common clinical marker whose quantification relies on immunoassays, giving variable results as batch, brand, or target epitope changes. Sheathless CE‐ESI‐MS, combining CE resolution power and low‐flow ESI sensitivity, was applied to the analysis of PTH in its native conformation in the presence of related forms. Fused silica and neutral‐coated capillaries were investigated, as well as preconcentration methods such as transient isotachophoresis, field‐amplified sample injection (FASI), and electrokinetic supercharging (EKS). The method for the separation of PTH and its variants was first developed using fused‐silica capillary with UV detection. An acidic BGE was used to separate 1–84 PTH (full length), 7–84 PTH, and 1–34 PTH. Acetonitrile was added to the BGE to reduce peptide adsorption onto the capillary wall and transient isotachophoresis was used as analyte preconcentration method. The method was then transferred to a sheathless CE‐ESI‐MS instrument. When using a fused silica capillary, CE‐MS was limited to μg/mL levels. The use of a neutral coating combined with FASI or EKS allowed a significant increase in sensitivity. Under these conditions, 1–84 PTH, 7–84 PTH, and 1–34 PTH were detected at concentrations in the low ng/mL (FASI) or pg/mL (EKS) range.  相似文献   

12.
The temperature‐responsive poly (N, N‐diethylacrylamide) (pDEAAm) with narrower molecular weight distribution was prepared by the atom transfer radical polymerization and characterized by 1HNMR and gel permeation chromatography. The temperature‐responsive “tadpole‐shaped” BSA–pDEAAm hybrids were fabricated via a free Cys‐34 residue of bovine serum albumin (BSA) site specifically binding to the end group disulfide bonds of pDEAAm and characterized by native‐polyacrylamide gel electrophoresis (Native‐PAGE) and matrix‐assisted laser desorption/ionization time of flight mass spectrometry. Their temperature‐responsive behaviors were measured by ultraviolet‐visible spectra (UV‐Vis). The lower critical solution temperature (LCST) of the pDEAAm was identified as 28°C, and the LCST of BSA–pDEAAm hybrids was identified as 31°C. The morphologies of BSA–pDEAAm hybrids self‐assembled in the aqueous solutions with two different temperatures at 25 °C and 40°C were investigated by transmission electron microscopy. Below the LCST of BSA–pDEAAm hybrids, the separate spherical nanoparticles were observed. In contrast, bundles and clusters were observed above the LCST of BSA–pDEAAm hybrids. The results suggested that the self‐assembly morphology of BSA–pDEAAm hybrids depended upon the pDEAAm block in BSA–pDEAAm hybrids, and the morphology transitions were effected by the LCST of BSA–pDEAAm hybrids. It would be expected to be used in biomedicine and materials science. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

13.
This paper describes the preparation and optimization of packed capillary columns for reversed‐phase separation of steroids with CEC. The fabrication of on‐column frits is considered to be the most important step for obtaining a reproducible packed column for CEC separation. Porous silicate frits were generated in a fused‐silica capillary by heating the silica gel/sodium hydroxide solutions electrically. The optimized conditions involve silica gel (10.8%), sodium hydroxide (5.8%), and heating time (5 sec) with heating voltage (5V) for obtaining a 100‐μ end‐frit that can withstand pressure over 6000 psi. A HPLC pump was utilized to pack the 5‐μm ODS particle slurry into the capillary column. The ODS packed capillaries were then utilized for the separation of four anabolic cholesterols with a capillary electrophoresis system without pressurization of the column. The reproducibility of the packed columns was evaluated by measuring the relative standard deviations of four steroids. The relative standard deviations of migration time for column‐to‐column, day‐to‐day, and run‐to‐run are less than 7%, 2%, and 1% for four steroids, respectively.  相似文献   

14.
A laboratory‐made INSTCoated fused‐silica capillary has been newly used for CE separation of four mixtures of proteins in sodium phosphate BGEs at pH 3.0 and 2.5, respectively. The obtained separation efficiencies range from 145 000 theoretical plates per meter for myoglobin to 1 216 000 m?1 for lysozyme. A total of 49–89% of the number of theoretical plates was obtained in a commercial polyvinyl alcohol coated capillary compared to the INSTCoated capillary under the same experimental conditions, 0–86% was obtained in a laboratory polyacrylamide‐coated capillary, and only 0–6% was obtained in an uncoated fused‐silica capillary. The RSD values for the intraday repeatability for an INSTCoated capillary were 0.1–1.0% (migration time) and 0.3–2.4% (peak area); RSD values for the interday repeatability in the same capillary are 0.6–1.4% (migration time) and 2.4–5.5% (peak area); RSD values for interday repeatability between different capillaries equaled 1.7–2.1% (migration time) and 2.8–10.9% (peak area). The INSTCoated capillary has been further used for rapid determination of globin chains isolated from red blood cells. A separation of α and β chains prepared from adult blood has been completed in 3 min with a peak resolution of 1.3, and the separation of α and Gγ chains prepared from newborn blood took 3 min with a peak resolution of 3.6.  相似文献   

15.
The quantum mechanics (QM) method and grand canonical Monte Carlo (GCMC) simulations are used to study the effect of lithium cation doping on the adsorption and separation of CO2, CH4, and H2 on a twofold interwoven metal–organic framework (MOF), Zn2(NDC)2(diPyNI) (NDC=2,6‐naphthalenedicarboxylate; diPyNI=N,N′‐di‐(4‐pyridyl)‐1,4,5,8‐naphthalenetetracarboxydiimide). Second‐order Moller–Plesset (MP2) calculations on the (Li+–diPyNI) cluster model show that the energetically most favorable lithium binding site is above the pyridine ring side at a distance of 1.817 Å from the oxygen atom. The results reveal that the adsorption capacity of Zn2(NDC)2(diPyNI) for carbon dioxide is higher than those of hydrogen and methane at room temperature. Furthermore, GCMC simulations on the structures obtained from QM calculations predict that the Li+‐doped MOF has higher adsorption capacities than the nondoped MOF, especially at low pressures. In addition, the probability density distribution plots reveal that CO2, CH4, and H2 molecules accumulate close to the Li cation site. The selectivity results indicate that CO2/H2 selectivity values in Zn2(NDC)2(diPyNI) are higher than those of CO2/CH4. The selectivity of CO2 over CH4 on Li+‐doped Zn2(NDC)2(diPyNI) is improved relative to the nondoped MOF.  相似文献   

16.
Bound rubber in a filled rubber compound is formed by physical adsorption and chemisorption between the rubber and the filler. Styrene–butadiene rubber (SBR) is composed of four components of styrene, cis‐1,4‐, trans‐1,4‐, and 1,2‐units. Filler–polymer interactions in both silica and carbon black‐filled SBR compounds were studied by analyzing microstructures of the bound rubbers with pyrolysis‐gas chromatography. Differences in the filler–polymer interactions of the styrene, cis‐1,4‐, trans‐1,4‐, and 1,2‐units were investigated. The filler–polymer interactions of the butadiene units were found to be stronger than that of the styrene unit. The interactions of the cis‐1,4‐ and trans‐1,4‐units were stronger with carbon black than with silica, whereas the 1,2‐unit interacted more strongly with silica than with carbon black. © 2001 John Wiley & Sons, Inc. J Polym Sci B: Polym Phys 39: 439–445, 2001  相似文献   

17.
In this study, an open‐tubular capillary electrochromatography (OT‐CEC) column with a monolithic layer of molecularly imprinted polymer (MIP) based on methacrylic acid, ethylene glycol dimethacrylate, and 4‐styrenesulfonic acid was utilized for the simultaneous separation and characterization of phospholipid (PL) molecular structures by interfacing with electrospray ionization‐tandem mass spectrometry (ESI‐MS‐MS). Introducing an MIP‐based monolith along with charged species at the OT column made it possible to separate PL molecules based on differences in head groups and acyl chain lengths in CEC. For the interface of OT‐CEC with ESI‐MS‐MS, a simple nanospray interface utilizing a sheath flow was developed and the resulting OT‐CEC‐ESI‐MS‐MS was able to separate PL standards (phosphatidylserines, phosphatidylethanolamines, phosphatidylglycerols, phosphatidic acid, and lysophosphatidylglycerols). The developed method was applied to human urinary lipid extracts, and resulted in the separation and structural identification of 18 molecules by data‐dependent collision‐induced dissociation.  相似文献   

18.
The novel enantiomeric separation of acidic and neutral compounds by capillary electrochromatography with β‐cyclodextrin‐bonded positively charged polyacrylamide gels was examined. The columns used are capillaries filled with a positively charged polyacrylamide gel, a so‐called monolithic stationary phase, to which allyl carbamoylated β‐CD derivatives covalently bind. The capillary wall was activated first by bifunctional reagent to make the resulting gel bind covalently inside the fused‐silica tubing. Enantiomeric separations of sixteen acidic and two neutral compounds were achieved using the above‐mentioned columns and 200 mmol dm–3 Tris–300 mmol dm–3 boric acid buffer (pH 8.1) as a mobile phase. High efficiencies of up to 150 000 plates m–1 were obtained for dansyl‐DL‐amino acids. The within‐run and between‐run reproducibilities of retention time and separation factor were examined for three dansyl‐DL‐amino acids and warfarin. The relative standard deviations of the within‐run and between‐run reproducibilities of retention time were less than 1.2 and 1.3% over the six injections, respectively. Those of the separation factor were less than 0.3 and 0.2%, respectively. The gel‐filled capillaries were stable for at least four months with intermittent use.  相似文献   

19.
Phospholipid vesicles were covalently attached to iminoaldehyde‐coated fused silica capillaries and applied to the separation of model steroids by open‐tubular CEC (OT‐CEC). The effects of reducing the formed Schiff's base with sodium borohydride and of the liposome composition on the stability of the coating were investigated. In addition, the studies were focused on the optimization of running conditions (pH values and composition of BGE solution) when CEC, using capillaries covalently bound with liposome dispersions, was coupled to MS. The effect of cholesterol in the liposome dispersion on the binding of model analytes was studied, using liposome dispersions comprising 80:20 mol% zwitterionic 1‐palmitoyl‐2‐oleyl‐sn‐glycero‐3‐phosphocholine (POPC) and the negatively charged phospholipid 1 ‐ palmitoyl‐2‐oleoyl‐sn‐glycero‐3‐phospho‐l ‐serine (POPS) and 40:40:20 mol% POPC/POPS/cholesterol. Cholesterol in liposomes (greatly) enhanced the stability of the capillaries by making the coatings more rigid, resulting in lower retention factors for all the studied model steroids. Although most of the studies were carried out by open tubular CEC‐UV Vis, the applicability of the capillaries to on‐line CEC‐MS was demonstrated as well. On‐line CEC‐MS studies on model steroids proved the suitability of coated capillaries for analyte–lipid membrane interaction studies, and especially for such analytes that are difficult to detect by conventional on‐line UV Vis.  相似文献   

20.
Monolithic columns having long hydrocarbon chains were prepared by in-situ polymerization in capillary fused silica tubing. The capillary columns were coupled with a newly developed carbon fiber electrospray ionization (ESI) emitter for proteomic analysis using sheathless capillary HPLC-ESI mass spectrometry (MS). The sample loading capacity and chromatographic performance of the styrene-based monolithic column, which was prepared by photo-polymerization of octylstyrene (OS) and divinylbenzene (DVB) were compared with that of the methacrylate-based monolithic column composed of lauryl methacrylate (LMA) and ethylene dimethacrylate (EDMA). The sample loading ability of tryptic digested protein in poly-OS (POS)-DVB column was higher than that of poly-LMA (PLMA)-EDMA column, possibly due to the irregular and rugluous surface offering a greater surface area of POS-DVB stationary phase. The POS-DVB column also provided better separation efficiency in the separation of high concentration (10 microg) of tryptic digested albumin bovine serum (BSA). Due to the successful interface of a highly efficient monolithic column and a stable, durable carbon fiber emitter, low femtomole levels of peptides were successfully separated and identified in the presence of large amounts of tryptic digested protein.  相似文献   