首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 871 毫秒
1.
We have developed a highly sensitive and positively charged precolumn derivatization reagent, (5‐N‐succinimidoxy‐5‐oxopentyl)triphenylphosphonium bromide (SPTPP), for amines and amino acids in liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI‐MS/MS). The handling of the derivatization reaction is quite simple and the reagent reacts with the analytes rapidly and with high efficiency. The derivatized analytes were observed to form regular and intense product ions upon MS/MS analysis; thus, highly sensitive and selective detection was possible in the selected reaction monitoring (SRM) mode. The limits of detection of the SPTPP‐derivatized analytes were less than sub‐femtomole levels. The sensitivities of the derivatized analytes increased about 500‐fold compared to those of underivatized analytes. Since the hydrophobicities of the samples increased after their derivatization, the resolution of the analytes improved dramatically when a reversed‐phase system was used. The relative standard deviations of intra‐day and inter‐day variations were below 10.6% and 13.3%, respectively. The accuracy ranged between 86.6–113% and 83.4–113%, respectively. Furthermore, the developed reagent was used for the analysis of the neurotransmitter 4‐aminobutanoic acid (GABA) and oxidative stress markers such as oxidized, nitrated, and halogenated tyrosines in rat serum. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

2.
An automated method for high‐throughput amino acid analysis, using precolumn derivatization high‐performance liquid chromatography/electrospray mass spectrometry (HPLC/ESI‐MS), was developed and evaluated. The precolumn derivatization step was performed in the reaction port of a home‐built auto‐sampler system. Amino acids were derivatized with 3‐aminopyridyl‐N‐hydroxysuccinimidyl carbamate, and a 3 μm Wakosil‐II 3C8‐100HG column (100 × 2.1 mm i.d.) was used for separation. To achieve a 13 min cycle for each sample, the derivatization and separation steps were performed in parallel. The results of the method evaluation, including the linearity, and the intra‐ and inter‐precision, were sufficient to measure physiological amino acids in human plasma samples. The relative standard deviations of typical amino acids in actual human plasma samples were below 10%. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

3.
A new, specific and sensitive GC‐MS method with electron impact ionization technique was developed for quantitative analysis of ezetimibe (EZE) in human plasma. Prior to GC analysis, EZE was derivatized with N‐methyl‐N‐trimethylsilyl‐trifluoroacetamide (MSTFA), which is a trimethyl silylating reagent. The derivatization reaction was optimized and parameters such as catalyst, derivatization time, temperature, solvent and the volume of silylating reagent were investigated. Trimethylsilyl ether derivative of EZE was determined in selected ion monitoring (SIM, mass‐to‐charge ratio (m/z): 326) mode. The method was validated with respect to LOD and LOQ, precision, accuracy, linearity, specificity, stability, and recovery. The LOQ and LOD were found as 15 and 10 ng/mL, respectively. The linearity of the method ranged from 15 to 250 ng/mL. The correlation coefficient of the calibration curve was 0.9977 ± 0.0004 (± S.E.M.). The intra‐ and inter‐day precisions (RSD) were less than 6% and accuracies (bias) for intra‐ and inter‐day accuracy were found between –4.04 and 9.71% at four different concentration levels (15, 40, 100, 250 ng/mL). The proposed method was successfully applied to real human plasma samples for determination of total EZE.  相似文献   

4.
We developed a simple, rapid and reliable method for determination of 20 common amino acids based on derivatization with 9‐fluorenylmethyl chloroformate (FMOC‐Cl) and RP‐LC/UV, this method was first introduced into quantitative analysis of amino acids. The amino groups of amino acids were trapped with FMOC‐Cl to form amino acid‐FMOC‐Cl adducts which can be suitable for LC‐UV. Chromatographic separation was performed on a C18 column with a mobile phase gradient consisting of acetonitrile and sodium acetate solution. This method was shown to be sensitive for 20 common amino acids. In the intra‐day precisions assay, the range of RSDs was 3.21‐7.67% with accuracies of 92.34‐102.51%; for the inter‐day precisions assay, the range of RSDs was 5.82‐9.19% with accuracies of 90.25‐100.63%. The results also indicated that solutions of amino acids‐FMOC‐Cl can be kept at room temperature for at least 24 h without showing significant losses in the quantified values. The validated method was successfully applied to the determination of major four kinds of amino acids in R. isatidis samples (Arg, Pro, Met and Val). The total content of amino acids in different origin R. isatidis was 13.32‐19.16 mg/g. The differences between R. isatidis samples were large using HCA.  相似文献   

5.
A direct injection liquid chromatography–electrospray ionization–tandem mass spectrometric method (LC‐ESI‐MS/MS) was developed and validated for the rapid and simple determination of 13 phenylalkylamine derivatives. Eight deuterium‐labeled compounds were prepared for use as internal standards (ISs) to quantify the analytes. Urine samples mixed with ISs were centrifuged, filtered through 0.22 µm filters and then injected directly into the LC‐ESI‐MS/MS system. The mobile phase was composed of 0.2% formic acid and 2 mM ammonium formate in distilled water and 0.2% formic acid and 2 mM ammonium formate in acetonitrile. The analytical column was a Capcell Pak MG‐II C18 (150 × 2.0 mm i.d., 5 µm, Shiseido). Separation and detection of the analytes were accomplished within 10 min. The linear ranges were 5–750 ng/mL (ephedrine and fenfluramine), 10–750 ng/mL (3,4‐methylenedioxyamphetamine, phendimetrazine, methamphetamine, 3,4‐methylenedioxyethylamphetamine and benzphetamine), 20–750 ng/mL (norephedrine, amphetamine, phentermine and ketamine) and 30–1000 ng/mL (3,4‐methylenedioxymethamphetamine and norketamine), with determination coefficients, R2, ≥ 0.9967. The intra‐day and inter‐day precisions were within 19.1%. The intra‐day and inter‐day accuracies ranged from ?16.0 to 18.7%. The lower limits of quantification for all the analytes were lower than 26.5 ng/mL. The applicability of the method was examined by analyzing urine samples from drug abusers (n = 30). Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

6.
Isoflavones containing foods and dietary supplements are widely consumed for putative health benefits (e.g. cancer chemoprevention, beneficial effects on serum lipids associated with cardiovascular health, reduction of osteoporosis, relief of menopausal symptoms). This paper describes the development and validation of a sensitive high throughput LC‐ESI‐MS/MS method for quantifying biochanin A (BCA) and genistein (GEN), and their conjugates in rat plasma. The analytes were separated on a Supelco Discovery C18 (4.6×50 mm, 5.0 μm) column under isocratic condition using acetonitrile/methanol (50:50, v/v) and 0.1% acetic acid in the ratio of 90:10 v/v as a mobile phase. The intra‐ and inter‐day assay precision ranged from 2.66 to 8.34% and 4.40 to 8.10% (RSD %), respectively, and intra‐ and inter‐day assay accuracy was between 90.67–109.25% and 95.86–106.32%, respectively, for both the analytes. The lowest quantitation limit for BCA and GEN was 0.5 ng/mL in 0.1 mL of rat plasma. The method was successfully applied to the estimation of BCA, GEN and their conjugates in rat plasma following oral administration of BCA. Circulating conjugates (glucuronides/sulfates) of BCA and GEN were quantified using enzymatic hydrolysis of plasma samples. The levels of isoflavones glucuronides/sulfates were found to be much greater than the corresponding aglycones.  相似文献   

7.
Determination of amino acids in biofluids is a challenging task because of difficulties deriving from their high polarity and matrix interference. A simple, reliable and high‐throughput hydrophilic interaction UHPLC–MS/MS method was developed and validated for the rapid simultaneous determination of 19 free amino acids in rat plasma and urine samples in this paper. Hydrophilic method with a Waters Acquity UPLC BEH Amide column (100 × 2.1 mm,1.7 μm) was used with a gradient mobile phase system of acetonitrile and water both containing 0.2% formic acid. The analysis was performed on a positive electrospray ionization mass spectrometer via multiple reaction monitoring. Samples of 10 μL plasma and 50 μL urine were spiked with three deuterated internal standards, pretreated with 250 μL acetonitrile for one‐step protein precipitation and a final dilution of urine samples. Good linearities (r > 0.99) were obtained for all of the analytes with the lower limit of quantification from 0.1 to 1.2 μg/mL. The relative standard deviation of the intra‐day and inter‐day precisions were within 15.0% and the accuracy ranged from ?12.8 to 12.7%. The hydrophilic interaction UHPLC–MS/MS method was rapid, accurate and high‐throughput and exhibited better chromatography behaviors than the regular RPLC methods. It was further successfully applied to detect 19 free amino acids in biological matrix.  相似文献   

8.
Ionization efficiency (IE) in mass spectrometry (MS) has been studied for many different compounds, and different IE scales have been constructed in order to quantitatively characterize IE. In the case of MS, derivatization has been used to increase the sensitivity of the method and to lower the limits of detection. However, the influence of derivatization on IE across different compounds and different derivatization reagents has not been thoroughly researched, so that practitioners do not have information on the IE‐enhancing abilities of different derivatization reagents. Moreover, measuring IE via direct infusion of compounds cannot be considered fully adequate. Since derivatized compounds are in complex mixtures, a chromatographic method is needed to separate these compounds to minimize potential matrix effects. In this work, an IE measurement system with a chromatographic column was developed for mainly amino acids and some biogenic amines. IE measurements with liquid chromatography electrospray ionization mass spectrometry (LC/ESI/MS) were carried out, and IE scales were constructed with a calibration curve for compounds with and without derivatization reagent diethyl ethoxymethylenemalonate. Additionally, eluent composition effects on ionization were investigated. Results showed that derivatization increases IE for most of the compounds (by average 0.9 and up to 2‐2.5 logIE units) and derivatized compounds have more similar logIE values than without derivatization. Mobile phase composition effects on ionization efficiencies were negligible. It was also noted that the use of chromatographic separation instead of flow injection mode slightly increases IE. In this work, for the first time, IE enhancement of derivatization reagents was quantified under real LC/ESI/MS conditions and obtained logIE values of derivatized compounds were linked with the existing scale.  相似文献   

9.
D Zhao  M Lu  Z Cai 《Electrophoresis》2012,33(15):2424-2432
An efficient and sensitive method for the separation and determination of three essential amino acids and three B vitamins by CE-LIF with a simultaneous derivatization procedure was developed. The conditions for derivatization and separation of these micronutrients were investigated. FITC was used as the reagent for fluorescence tagging of arginine (Arg), valine (Val), tryptophan (Trp), folic acid (FA), and niacinamide (NA). Riboflavin (RF) was detected without derivatization. Derivatization of analytes dissolved in borate solution was performed by successive introduction of fluorescence reagent and analytes followed by water bathing at 43°C. The molar ratio of sample/reagent (S/R), derivatization temperature, and incubation time significantly influenced the efficiency of derivatization. To maximize the fluorescence yield, a high S/R (≥20) was required. The nonderivatized RF and five derivatized analytes were separated in the optimized CE-LIF system with the application of 22 kV voltage and 25 mM borate buffer at pH 9.85. Validation of the method showed good linearity for the corrected peak areas versus standard concentrations for the six analytes. The RSDs (n = 3) of the migration time and the peak area obtained for the analytes ranged from 0.4 to 1.1% and from 1.9 to 4.4%, respectively. The developed method, with the lowest LOD of 0.5 nM, was successfully applied for the efficient derivatization and determination of B vitamins in four health drink samples.  相似文献   

10.
A novel method of amino acid analysis using derivatization of multiple functional groups (amino, carboxyl, and phenolic hydroxyl groups) was applied to measure glycated amino acids in order to quantify glycated peptides and evaluate the degree of glycation of peptide. Amino and carboxyl groups of amino acids were derivatized with 1‐bromobutane so that the hydrophobicities and basicities of the amino acids, including glycated amino acids, were improved. These derivatized amino acids could be detected with high sensitivity using LC‐MS/MS. In this study, 1‐deoxyfructosyl‐VHLTPE and VHLTPE, which are N‐terminal peptides of the β‐chains of hemoglobin, were selected as target compounds. After reducing the peptide sample solution with sodium borohydride, the obtained peptides were hydrolyzed with hydrochloric acid. The released amino acids were then derivatized with 1‐bromobutane and analyzed with LC‐MS/MS. The derivatized amino acids, including glycated amino acids, could be separated using an octadecyl silylated silica column and good sharp peaks were detected. We show a confirmatory experiment that the proposed method can be applied to evaluate the degree of glycation of peptides, using mixtures of glycated and non‐glycated peptide. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

11.
This study aimed to develop a specific UHPLC‐ESI‐MS/MS method for simultaneous determination and pharmacokinetics of pinoresinol glucoside and chlorogenic acid in rat plasma after oral administration of Eucommia ulmoides . The chromatographic separation was achieved on a Hypersil GOLD column with gradient elution by using a mixture of 0.1% formic acid aqueous solution and acetonitrile as the mobile phase at a flow rate of 200 μL/min. A tandem mass spectrometric detection was conducted using multiple‐reaction monitoring via an electrospray ionization source in negative ionization mode. Samples were pre‐treated by a single‐step protein precipitation with acetonitrile, and bergenin was used as internal standard. After oral administration of 3 mL/kg E. ulmoides extract in rats, the maximum plasma concentrations of pinoresinol glucoside and chlorogenic acid were 57.44 and 61.04 ng/mL, respectively. The times to reach the maximum plasma concentration were 40.00 and 23.33 min for pinoresinol glucoside and chlorogenic acid, respectively. The intra‐ and inter‐day precision (RSD) values for the two analytes were <2.46 and 5.15%, respectively, and the accuracy (RE) values ranged from −12.76 to 0.00. This is the first study on pharmacokinetics of bioactive compounds in rat plasma after oral administration of E. ulmoides extract.  相似文献   

12.
A sensitive and specific method based on liquid chromatography‐tandem mass spectrometry using electrospray ionization (LC‐ESI‐MS/MS) has been developed for the determination of Schisandrin and Schisandrin B in rat plasma. A 100 μL plasma sample was extracted by methyl tert‐butyl ether after spiking the samples with nimodipine (internal standard) and performed on an XTerra®MS‐C18 column (150 mm × 2.1 mm, 3.5 μm) with the mobile phase of acetonitrile–water–formic acid (80:20:0.2, v/v) at a flow rate of 0.2 mL/min in a run time of 8.5 min. The lower limit of quantification of the method was 40 ng/mL for Schisandrin and 20 ng/mL for Schisandrin B. The method showed reproducibility with intra‐day and inter‐day precision of less than 13.8% RSD, as well as accuracy, with inter‐ and intra‐assay accuracies between 93.5 and 107.2%. Finally, the LC‐ESI‐MS/MS method was successfully applied to study the pharmacokinetics of Schisandrin and Schisandrin B in rats after administration of Wurenchun commercial formulations to rats. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

13.
To explore whether alcohol has an effect on the pharmacokinetic behavior of phenolic acids, the main bioactive constituents in red wine, a highly sensitive and simple ultra‐fast liquid chromatography coupled with triple quadrupole mass spectrometry (UFLC–MS/MS) method was developed for simultaneous quantitation of eight phenolic acids in plasma samples. Plasma samples were extracted by liquid–liquid extraction and the chromatographic separation was achieved on a Zorbax SB‐C18 column within 7.0 min. Results of the validated method revealed that all of the calibration curves displayed good linear regression (r > 0.99). The intra‐ and inter‐day precisions of the analytes were <14.0% and accuracies ranged from ?8.5 to 7.3%. The extraction recoveries of the analytes were from 71.2 to 110.2% and the matrix effects ranged from 86.2 to 105.5%. The stability of these compounds under various conditions satisfied the requirements of biological sample measurement. The method was successfully applied to a comparative pharmacokinetic study of phenolic acids in rat plasma. For gallic acid and gentisic acid, the parameters AUC0–t and AUC0– increased remarkably (p < 0.05) after oral administration of red wine, which suggested that alcohol might enhance their absorption. This is the first report to compare the pharmacokinetic behavior of phenolic acids in red wine and dealcoholized red wine.  相似文献   

14.
The rapid determination of three benzophenone‐type UV filters: 2‐hydroxy‐4‐methoxy‐benzophenone (BP‐3), 2,4‐dihydroxybenzophenone (BP‐1) and 2,2′‐dihydroxy‐4‐methoxy‐benzophenone (BP‐8), in aqueous samples is described. The method involved the extraction of an aqueous sample using an Oasis HLB solid‐phase extraction (SPE) cartridge, followed by on‐line derivatization gas chromatography ‐ tandem mass spectrometry (GC‐MS/MS) with a trimethylsilylating (TMS) reagent. This eco‐friendly, injection‐port derivatization method, is sensitive, rapid, and provides reproducible results for these hydroxylated benzophenones in aqueous samples. The limits of quantitation (LOQs) were determined to be 1.0 to 2.5 ng/L for samples in 100 mL of water. The precision for these analytes, as indicated by relative standard deviations (RSDs), proved to be less than 11% for both intra‐ and inter‐day analysis. Accuracy, expressed as the mean extraction yield, was between 80 and 106%. The method was then applied to some environmental water samples, river water and samples of effluents from a wastewater treatment plant (WWTP), having the potential to contain BP‐3 and BP‐1.  相似文献   

15.
S‐methylcysteine (SMC) is a minor amino acid naturally excreted in human urine, a protective agent against oxidative stress and a biotransformation product of the fumigant biocide methyl bromide and of nicotine. A metabolic source of SMC is catabolism of the repair catalytic protein MGMT (EC 2.1.1.37), which specifically removes the methyl group from the modified DNA nucleotide O‐6‐methyl‐guanine to revert the normal GC base pairing. To assess the value of SMC and of S‐methylmercapturic acid (SMMA) as candidate biomarkers of proliferative phenomena, a sensitive analytical method by GC‐MS was applied in a pilot study of healthy subjects to assess their urinary elimination and the intra‐ and inter‐individual variability. Extractive alkylation with butylchloroformate‐n‐butanol‐pyridine (Husek technique) was employed for sample derivatization and isotope dilution GC‐MS with S‐[CD3]‐SMC and ‐SMMA was applied for specific and sensitive detection. To resolve the target analytes from the main coeluting interferents in the derivatized urine extract a medium‐polarity stationary phase was employed. SMMA was not detected in the morning urine of three healthy fertile‐age women followed for one month above the minimum detectable level of approx. 500 µg/L while SMC concentrations were in the 0.02–0.7 µg/mL range (n = 61) with large inter‐day and inter‐individual variations. In a young healthy male urine samples taken throughout a few days yielded concentrations in the same 90–810 µg/L range (n = 11). These preliminary results points at SMC as a candidate biomarker for the study of methylation turnover in several biochemical processes. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

16.
A simple and practical derivatization procedure for increasing the detectability and enantiomeric separation of chiral carboxylic acids in LC/ESI‐MS/MS has been developed. (S)‐Anabasine (ANA) was used as the derivatization reagent and rapidly reacted with carboxylic acids [3‐hydroxypalmitic acid (3‐OH‐PA), 2‐(β‐carboxyethyl)‐6‐hydroxy‐2,7,8‐trimethylchroman (γ‐CEHC), and etodolac] in the presence of 4‐(4,6‐dimethoxy‐1,3,5‐triazin‐2‐yl)‐4‐methylmorpholium chloride. The resulting ANA‐derivatives were highly responsive in ESI‐MS operating in the positive‐ion mode and gave characteristic product ions during MS/MS, which enabled sensitive detection using selected reaction monitoring; the detection responses of the ANA‐derivatives were increased by 20–160‐fold over those of the intact carboxylic acids and the limits of detection were in the low femtomole range (1.8–11 fmol on the column). The ANA‐derivatization was also effective for the enatiomeric separation of the chiral carboxylic acids; the resolution was 1.92, 1.75, and 2.03 for 3‐OH‐PA, γ‐CHEC, and etodolac, respectively. The derivatization procedure was successfully applied to a biological sample analysis; the derivatization followed by LC/ESI‐MS/MS enabled the separation and detection of trace amounts of 3‐OH‐PA in neonatal dried blood spot and γ‐CEHC in human saliva with a simple pretreatment and small sample volume.  相似文献   

17.
A sensitive, versatile, and reproducible automatic analyzer for highly polar carboxylic acids based on a fluorescence derivatization–liquid chromatography (LC) method was developed. In this method, carboxylic acids were automatically and fluorescently derivatized with 4‐(N,N‐dimethylaminosulfonyl)‐7‐piperazino‐2,1,3‐benzoxadiazole (DBD‐PZ) in the presence of 4‐(4,6‐dimethoxy‐1,3,5‐triazin‐2‐yl)‐4‐methylmorpholinium chloride by adopting a pretreatment program installed in an LC autosampler. All of the DBD‐PZ‐carboxylic acid derivatives were separated on the ODS column within 30 min by gradient elution. The peak of DBD‐PZ did not interfere with the separation and the quantification of all the acids with the exception of lactic acid. From the LC‐MS/MS analysis, we confirmed that lactic acid was converted to an oxytriazinyl derivative, which was further modified with a dimethoxy triazine group of 4‐(4,6‐dimethoxy‐1,3,5‐triazin‐2‐yl)‐4‐methylmorpholinium chloride (DMT‐MM). We detected this oxytriazinyl derivative to quantify lactic acid. The detection limits (signal‐to‐noise ratio = 3) for the examined acids ranged from 0.19 to 1.1 µm , which correspond to 95–550 fmol per injection. The intra‐ and inter‐day precisions of typical, highly polar carboxylic acids were all <9.0%. The developed method was successfully applied to the comprehensive analysis of carboxylic acids in various samples, which included fruit juices, red wine and media from cultured tumor cells. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

18.
Oleuropein (OE) is the cardinal bioactive compound derived from Olea europaea and possesses numerous beneficial properties for human health. However, despite the plethora of analytical methods that have studied the biological fate of olive oil‐derived bioactive compounds, no validated methodology has been published to date for the simultaneous determination of OE, along with all its major metabolites. In this study, a liquid chromatography‐electrospray ionization‐tandem mass spectrometry (LC‐ESI MS/MS) method has been developed and validated for the quantification of OE, simultaneously with its main metabolites hydroxytyrosol, 2‐(3,4‐dihydroxyphenyl)acetic acid, 4‐(2‐hydroxyethyl)‐2‐methoxy‐phenol or homovanillyl alcohol, 2‐(4‐hydroxy‐3‐methoxyphenyl)acetic acid or homovanillic acid, and elenolic acid in rat plasma matrix. Samples were analyzed by LC‐ESI MS/MS prior to and after enzymatic treatment. A solid‐phase extraction step with high mean recovery for all compounds was performed as sample pretreatment. Calibration curves were linear for all bioactive compounds over the range studied, while the method exhibited good accuracy, intra‐ and inter‐day precision. The limit of detection was in the picogram range (per milliliterof plasma) for HT and OE and in the nanogram range (per milliliter of plasma) for the other analytes, and the method was simple and rapid. The developed methodology was successfully applied for the simultaneous quantification of OE and its aforementioned metabolites in rat plasma samples, thus demonstrating its suitability for pharmacokinetics, as well as bioavailability and metabolism studies. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

19.
Luteoloside is a potential anticarcinogenic component isolated from Lonicera japonica, a traditional Chinese medicine (TCM). This study details the development and validation of a sensitive and accurate HPLC‐ESI‐MS/MS method for the quantification of luteoloside in dog plasma. Sample pretreatment includes simple protein precipitation using methanol–acetonitrile (1:1, v/v). A Phenomenex Gemini C18 column (2.0 × 50 mm, i.d., 3.5 µm) was used to separate luteoloside and internal standard by gradient mode with mobile phase consisting of water containing 0.1% formic acid and methanol containing 0.1% formic acid at a flow rate of 0.40 mL/min with a column temperature of 25°C. The detection was performed by positive ion electrospray ionization (ESI) in multiple reaction monitoring mode. The calibration curves were linear (R > 0.995) over the concentration range 1.0–2000 ng/mL and the lower limit of quantification was 1.0 ng/mL. The intra‐day and inter‐day precisions (RSD) were all <15%, accuracies (RE) were within the range of ±15%, and recoveries were between 85.0 and 115%. The validated HPLC‐ESI‐MS/MS method was successfully applied to determine plasma concentrations of luteoloside after intravenous administration of luteoloside at a dose level of 20 mg/kg. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

20.
Derivatization at the injection port following hollow‐fiber‐based liquid–liquid–liquid microextraction with tetramethylammonium acetate as a dual‐function reagent, i.e. an acceptor and derivatization reagent, for the determination of benzoic acid (BA) and sorbic acid (SA) in real samples by GC was developed. BA and SA were extracted from aqueous samples to an organic phase impregnated into the pores of the hollow fiber wall, and then back‐extracted to the acceptor solution located inside the lumen of the hollow fiber. Upon injection, the extracted analytes were quantitatively derivatized to their methyl esters with tetramethylammonium acetate in the GC injection port. Several parameters related to the derivatization and extraction efficiency were optimized. The linearity was satisfactory over a concentration range of 0.1–50 mg/L with r > 0.993 for both analytes. The LODs were 2.0 μg/L for SA and 20 μg/L for BA. The recoveries (83–116%) and precisions (RSDs of 1.2–11.4% (n = 3)) were examined by analyzing real spiked samples. The enrichment factors of BA and SA were 300 and 425. The results demonstrated that this is a simple, rapid, accurate, and sensitive method for the determination of BA and SA in various samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号