首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
《Analytical letters》2012,45(8-9):539-543
Abstract

Silicone rubber membranes containing potassium zinc ferrocyanide have been assessed as ion-selective electrode sensors for the determination of alkali metal ions. The slope of the calibration graph for potassium ion is 59 mV per decade change in concentration within the concentration range 5 × 10?4 to 10?1 M at 25°C. Selectivity constants (KK + /M+)are 9. 5, Cs+; 3. 3, Rb+; 0. 025, Na+; 0. 003, Li+; and 1.8, NH4 +, calculated from potential data obtained at 10?1 M concentrations of each ion separately. Similar membranes prepared from PVC responded similarly with a slight improvement in selectivity.  相似文献   

2.
A potentiometric sensor based on the Schiff base 2,2′-(1E,1′E)-(1,1′-binaphthyl-2,2′-diylbis(azan-1-yl-1-ylidene))bis(methan-1-yl-1-ylidene)diphenol was synthesized and tested as an ionophore PVC-based membrane sensor selective towards silver ions (Ag+). Potentiometric testing demonstrated the high affinity of this receptor to silver ions. Seven membranes were fabricated with different compositions, with best performance shown by that with an ionophore composition (w/w) of 1.0?mg, PVC 33.0?mg, 2-nitrophenyl octyl ether 66?mg, and potassium tetrakis(p-chlorophenyl)borate 50?mol% in 1.0?mL tetrahydrofuran. The sensor worked well over a wide range of concentrations (1.0?×?10?2 to 1.0?×?10?6?M Ag+) at pH?6, showing a slope of 60.99?mV/dec with rapid response times of less than 3?s. The sensor also showed good selectivity towards Ag+ in the presence of interfering cations, with the highest selectivity coefficient observed for Hg2+ (2.7). A low detection limit of 3.4?×?10?7?M Ag+ was established.  相似文献   

3.
《Electroanalysis》2006,18(10):1019-1027
A new PVC membrane potentiometric sensor for Ag(I) ion based on a recently synthesized calix[4]arene compound of 5,11,17,23‐tetra‐tert‐butyl‐25,27‐dihydroxy‐calix[4]arene‐thiacrown‐4 is developed. The electrode exhibits a Nernstian response for Ag(I) ions over a wide concentration range (1.0×10?2?1.0×10?6 M) with a slope of 53.8±1.6 mV per decade. It has a relatively fast response time (5–10 s) and can be used for at least 2 months without any considerable divergence in potentials. The proposed electrode shows high selectivity towards Ag+ ions over Pb2+, Cd2+, Co2+, Zn2+, Cu2+, Ni2+, Sr2+, Mg2+, Ca2+, Li+, K+, Na+, NH4+ ions and can be used in a pH range of 2–6. Only interference of Hg2+ is found. It is successfully used as an indicator electrode in potentiometric titration of a mixture of chloride, bromide and iodide ions.  相似文献   

4.
Na-montmorillonites were exchanged with Li+, K+, Rb+, Cs+, Mg2+, Ca2+, Sr2+, and Ba2+, while Ca-montmorillonites were treated with alkaline and alkaline earth ions except for Ra2+ and Ca2+. Montmorillonites with interlayer cations Li+ or Na+ have remarkable swelling capacity and keep excellent stability. It is shown that metal ions represent different exchange ability as follows: Cs+?>?Rb+?>?K+?>?Na+?>?Li+ and Ba2+?>?Sr2+?>?Ca2+?>?Mg2+. The cation exchange capacity with single ion exchange capacity illustrates that Mg2+ and Ca2+ do not only take part in cation exchange but also produce physical adsorption on the montmorillonite. Although interlayer spacing d 001 depends on both radius and hydration radius of interlayer cations, the latter one plays a decisive role in changing d 001 value. Three stages of temperature intervals of dehydration are observed from the TG/DSC curves: the release of surface water adsorbed (36?C84?°C), the dehydration of interlayer water and the chemical-adsorption water (47?C189?°C) and dehydration of bound water of interlayer metal cation (108?C268?°C). Data show that the quantity and hydration energy of ions adsorbed on montmorillonite influence the water content in montmorillonite. Mg2+-modified Na-montmorillonite which absorbs the most quantity of ions with the highest hydration energy has the maximum water content up to 8.84%.  相似文献   

5.
A new PVC-membrane electrode for Co2+ ions based on N,N′-di(thiazol-2-yl)formimidamide (TF) as membrane carrier has been developed. The electrode resulted in Nernstian response (29.5?±?0.4?mV decade?1) for Co2+ ion over a wide concentration range (2.5?×?10?7 ?1.0?×?10?1?M) with a detection limit of 6.1?×?10?8?M. The sensor has a response time of about 10?s, and can be used for at least 2 months without observing any deviation from the Nernstain response. The electrode revealed good selectivity towards cobalt(II) ion over a wide variety of alkali, alkaline earth, transition, and heavy metal ions and could be used in the pH range 2.0–7.0. The electrode was used for determination of Co2+ in real samples.  相似文献   

6.
Guanidinium-selective membrane electrodes were constructed with dibenzo-24-crown-8, dibenzo-27-crown-9, tribenzo-27-crown-9 or dibenzo-30-crown-10. The detection limits and selectivity coefficients towards different interfering ions, such as Li+, Na+, K+, NH+4, Mg2+ and Ca2+ were determined. The electrode with dibenzo-27-crown-9 shows linear response over the range 10?1–10?4 M, with selectivity coefficients about 10?2 for most alkali and alkaline earth metal ions.  相似文献   

7.
5,11,17,23‐Tetra‐tert‐butyl‐25,26,27,28‐tetrakis(diphenylphosphinoylmethoxy)calix[4]arene ( 1 )has been used for the preparation of a graphite coated thorium ion‐selective electrode (Th4+‐ISE). The plasticized PVC membrane containing 30% PVC, 58% ortho‐nitrophenyloctylether (NPOE), 4% sodium tetraphenylborate (NaTPB) and 8% ionophore was directly coated on a graphite rod. This sensor gave good Nernstian responses with a slope of 15.5 ± 0.1 mV/decade over a concentration range of 1 × 10?5 ?1 × 10?3 M of thorium ions with a limit of detection of 7.9 × 10?6 M. The dynamic response time of the electrode to achieve a steady potential was found to be about 15 seconds. The potential of the prepared sensor was independent of the pH variation in the range 2.3–4.0. The selectivity relative to several mono‐, di‐ and tri‐valent metal ions, i.e. Li+, Na+, K+, Ag+, NH4+, Sr2+, Mn2+, Fe2+, Co2+, Ni2+, Cu2+, Zn2+, Cd2+, La3+, Sm3+, Dy3+, Er3+ and Y3+ was examined. This electrode can be used for 6 months without any considerable divergences in the potential response. The sensor was successfully used as an indicator electrode for the potentiometric titration of a thorium solution using a standard solution of EDTA.  相似文献   

8.
A density functional theory based on interaction of alkali metal cations (Li+, Na+, K+, Rb+ and Cs+) with cyclic peptides constructed from 3 or 4 alanine molecule (CyAla3 and CyAla4), has been investigated using mixed basis set (C, H, O, Li+, Na+ and K+ using 6-31+G(d), and the heavier cations: Rb+ and Cs+ using LANL2DZ). The minimum energy structures, binding energies, and various thermodynamic parameters of free ligands and their metal cations complexes have been determined with B3LYP and CAM-B3LYP functionals. The order of interaction energies were found to be Li> K> Na> Rb> Cs+ and Li> Na> K? Rb> Cs+, calculated at CAM-B3LYP level for the M/CyAla3 and M/CyAla4 complexes, respectively. Their selectivity trend shows that the highest cation selectivity for Li+ over other alkali metal ions has been achieved on the basis of thermodynamic analysis. The main types of driving force host–guest interactions are investigated, the electron-donating O offers lone pair electrons to the contacting LP* of alkali metal cations.  相似文献   

9.
A PVC membrane electrode for Hg(II) ions, based on a new cone shaped calix[4]arene (L) as a suitable ionophore was constructed. The sensor exhibits a linear dynamic in the range of 1.0 × 10?6–1.0 × 10?1 M, with a Nernstian slope of 29.4 ± 0.4 mV decade?1, and a detection limit of 4.0 × 10?7 M. The response time is quick (less than 10 s), it can be used in the pH range of 1.5–4, and the electrode response and selectivity remained almost unchanged for about 2 months. The sensor revealed comparatively good selectivity with respect to most alkali, alkaline earth, and some transition and heavy metal ions. It was successfully employed as an indicator electrode in the potentiometric titration of Hg2+ ions with potassium iodide, and the direct determination of mercury content of amalgam alloy and water samples.  相似文献   

10.
A novel potentiometric sensor based on screen‐printed carbon electrode covered with electropolymerized polyaniline (PANI) and unsubstituted pillar[5]arene as ionophore has been developed and tested in potentiometric measurements of pH and metal ions. The introduction of pillar[5]arene improved the reversibility of the pH response in the range from 2.0 to 9.0 with the slope of 45 mV/pH. Among metal cations, the response to Fe3+ and Ag+ ions was referred to PANI redox conversion whereas the signal toward Cu2+ in the range from 1.0×10?6 to 1.0×10?2 M (limit of detection (LOD) 3.0×10?7 M) to specific interaction with the macrocycle.  相似文献   

11.
《Analytical letters》2012,45(2):298-311
Abstract

A polyvinyl chloride (PVC) based membrane sensor for terbium ions was prepared by employing Hematoporphyrin (HP) as an ionophore. The sensor revealed a very good selectivity (expect for the Fe3+ion) with respect to common alkali, alkaline earth and heavy metal ions. The plasticized membrane electrode exhibits a Nernstian response for Tb3+ ions over a wide concentration range (1.0 × 10?6 ? 1.0 × 10?2 M) with a slope of 19.8±0.3 mV per decade and low detection limit of 7.4 × 10?7 M. The developed sensor was used in determination of F? in mouth wash preparation sample.  相似文献   

12.
Studies on complex formation of tris(3‐(2‐hydroxybenzophenone)propyl)amine (THPA) with a number of metal ions in acetonitrile solution revealed the occurrence of a selective 1 : 1 complexation of the proposed ligand with Sn2+ ion. Consequently, THPA was used as a suitable neutral ionophore for the preparation of a polymeric membrane‐selective electrode. The electrode exhibits a Nernstian behavior with a slope of 29.4±0.3 mV per decade and a detection limit of 2.0×10?7 M. It also showed a good selectivity for Sn2+ ions in comparison with some of group A and B metal ions over a wide concentration range of 5.0×10?7–1.0×10?1 M. Improved selectivity was achieved compared to the best selectivity recently reported by other authors for tin(II). The electrode was successfully applied to the determination of Sn2+ ion in waste water and various canned products.  相似文献   

13.
《Analytical letters》2012,45(14):2727-2742
Abstract

This report describes an attempt to develop potentiometric Mg2+ sensors based on a liquid polymeric membrane. Membrane incorporating 4,5-Bis(benzoylthio)-1,3- dithiole-2-thione (Bz2dmit) as ionophore, with composition Bz2 dmit:NaTPB:NB:PVC in the ratio 2.5:2.5:65:30 (w/w), exhibits the best result for potentiometric sensing of Mg2+ ions. The proposed electrode, based on Bz2 dmitwith nitrobenzene (NB) as a solvent mediator in a polyvinyl chloride (PVC) membrane matrix, exhibited a near-Nernstian response to Mg2+ in the concentration range of 1.0 × 10?5 to 1.0 × 10?1 M, with a slope of 29.2 mV per decade of activity of Mg2+. The lower limit of detection was 1.0 × 10?5 M. This sensor showed high selectivity with respect to alkaline, alkaline earth, transition, and heavy metal ions, except for Sr2+, and could be used over a pH range of 3.5–9.0. It can be used for at least 2 mo without considerable divergence in potentials and has a relatively fast response of <10 s. It was applied successfully as an indicator electrode in potentiometric titration of Mg2+ ions with EDTA.  相似文献   

14.
Extraction of lithium ions from salt‐lake brines is very important to produce lithium compounds. Herein, we report a new approach to construct polystyrene sulfonate (PSS) threaded HKUST‐1 metal–organic framework (MOF) membranes through an in situ confinement conversion process. The resulting membrane PSS@HKUST‐1‐6.7, with unique anchored three‐dimensional sulfonate networks, shows a very high Li+ conductivity of 5.53×10?4 S cm?1 at 25 °C, 1.89×10?3 S cm?1 at 70 °C, and Li+ flux of 6.75 mol m?2 h?1, which are five orders higher than that of the pristine HKUST‐1 membrane. Attributed to the different size sieving effects and the affinity differences of the Li+, Na+, K+, and Mg2+ ions to the sulfonate groups, the PSS@HKUST‐1‐6.7 membrane exhibits ideal selectivities of 78, 99, and 10296 for Li+/Na+, Li+/K+, Li+/Mg2+ and real binary ion selectivities of 35, 67, and 1815, respectively, the highest ever reported among ionic conductors and Li+ extraction membranes.  相似文献   

15.
《Electroanalysis》2004,16(12):1002-1008
Preliminary theoretical studies revealed the selective complexation of bis (2‐mercaptoanil) diacetyl (BMDA) with La3+ over several alkali, alkaline earth and heavy metal ions. Thus, novel PVC‐based membrane (PBM) and coated graphite membrane (CGM) sensors for La(III) based on BMDA were prepared. The electrodes display Nernstian behavior over wide concentration ranges (i.e., 1.0×10?5–1.0×10?1 M for PBM and 1.0×10?6–1.0×10?1 M for CGM). The potential response of sensors was pH independent in the range of 4.0–8.0. The sensors possess satisfactory reproducibility, fast response time (<15 s), and specially excellent discriminating ability for La3+ ions with respect to most of the cations. The membrane sensor was used as an indicator electrode in potentiometric titration of lanthanum ions with EDTA. The coated graphite membrane electrode was applied in determination of fluoride ions in mouth wash preparations.  相似文献   

16.
《Analytical letters》2012,45(17-18):1371-1380
Abstract

1,4,7,10-Tetraoxacyclododecane (12-crown-4) (I) and its lithium complex (II) are used as neutral carriers for lithium ion in polyvinylchloride membrane ion selective electrodes. The lithium response varies with concentration, being near Mernstian at low (10?5-10?4 M) concentrations and sub-Nernstian (24-28 aV) at higher concentrations (10?3 M). The selectivity coefficients KLi Pot M for II are: Na+ (0.12), K+ (0.66), Cs+ (0.15), Mg2+ (1.6 × 10?4), Ca2+ (3.1 × 10?4), Ba2+ (9.5 × 10?7), NH+ 4 (9.0 × 10?2), H+ (2.2).  相似文献   

17.
2,5-Dioxo-4-imidazolidinyl was used as an excellent sensing material in the preparation of a PVC membrane for a Ce(III)-selective sensor. The electrode shows a good selectivity for the Ce(III) ion with respect to most common cations including alkali, alkaline earth, transition, and heavy metal ions. The developed sensor exhibits a wide linear response with a slope of 19.6?±?0.3 mV per decade over the concentration range of 1.0?×?10?6 to 1.0?×?10?1 M, while the illustrated detection limit is 5.7?×?10?7 M of Ce(III) ions. Moreover, it is concluded that the sensor response is pH-independent in the range of 3.1–9.8. The applications of the recommended electrode include the determination of concentration of Ce(III) ions in soil and sediment samples, validation with CRM's, and the Ce(III) ion potentiometric titration with EDTA as an indicator electrode.  相似文献   

18.
《Analytical letters》2012,45(15):2444-2459
Abstract

Polymeric membrane electrodes (PMEs) and coated graphite electrodes (CGEs) containing 1,3,4-trisubstituted-2-azetidinone derivatives as ion carriers are reported here for bismuth(III) ion selectivity. These electrodes exhibited Nernstian response for Bi3+ ions over a wide concentration range (5.0 × 10?7 M to 1.0 × 10?1 M for CGE) with a lower detection limit of 3.98 × 10?7 M (for CGE) and wide pH range (1.3–5.0). Compared to polymeric membrane electrode, the coated graphite electrode has shown better selectivity for Bi3+ ions with respect to common metal ions. Proposed electrodes have been used for the estimation of Bi3+ ions in pharmaceutical and glass samples.  相似文献   

19.
Introduction  Ionchromatography (IC)hasbeenrecognizedasausefulmethodfortheseparationofinorganicanionsandcationssinceitsintroductionbySmalletal .in 1975 .1AsignificanttrendinthedevelopmentofICmethodissearchforsensitiveanduniversaldetectionmethods .Themaindet…  相似文献   

20.
A new PVC membrane coated graphite electrode for cesium ion based on 4′,4″(5′)di–tert-butyl di-benzo-18-crown-6 (DTBDB18C6) as ionophore was prepared. The electrode shows a near Nernstian response of 57.0 ± 1.8 mV decade?1 over a wide activity range of 6.0 × 10?6–1.0 × 10?1 mol L?1 with a limit of detection 4.0 × 10?6 mol L?1. The proposed electrode is suitable for use in aqueous solution in the pH range of 3.0–9.5. It has a fast response time of 10 s and can be used for at least 1 month without any considerable divergence in potential. The selectivity coefficients for Cs+ ion with respect to ammonium, alkali, alkaline earth and some selected transition metal ions were determined and showed a superior selectivity over Li+, Na+ and alkaline earth metal ions. The new electrode was applied for determination of Cs+ in spiked tap water. The electrode was also used as indicator electrode in potentiometric titration of Cs+ with sodium tetraphenyl borate.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号