首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 765 毫秒
1.
《Electroanalysis》2004,16(12):1009-1013
A novel ion‐selective polymeric membrane sensor based on pyrylium‐4,4‐(1,4‐phenylen) bis[2,6‐bis(2‐naphthyl)]‐bis[tetrafluoroborate] (PBGNB) as an excellent sensing material is successfully developed. The electrode possesses the advantages of a very low detection limit (5.0×10?8 M), a wide working concentration range (1.0×10?8?1.0×10?1 M) and specially, a high sulfate selectivity over most common organic and inorganic anions. The sensor displays Nernstian behavior (slope of 29.5±0.5 mV per decade) in a wide pH range (3.0–8.5). It shows a short response time in the whole concentration range (ca. 10 s). The electrode was used as an indicator electrode in the potentiometric titration of sulfate ions with barium ions. The proposed sensor was successfully applied to the direct determination of salbutamol sulfate and paromomycin sulfate.  相似文献   

2.
A highly selective PVC‐membrane electrode based on 2,6‐diphenylpyrylium fluoroborate is presented. The electrode reveals a Nernstian potentiometric response for sulfate ion over a wide concentration range (5.0 × 10?6‐1.0 × 10?1 M). The electrode has a response time of about 10 s and can be used for at least 2 months without any divergence. The proposed sensor revealed very good selectivities for sulfate over a wide variety of common organic and inorganic anions and could be used over a wide pH range (2.5–9.5). The detection limit of the sensor is 3.0 × 10?6 M. It was successfully applied to the direct determination of salbutamol, paramomycin tablets, and as an indicator electrode for potentiometric titration of sulfate ions with barium ions.  相似文献   

3.
A composite multiwalled carbon nanotube polyvinyl chloride electrode based on 7,16‐dibenzyl‐1,4,10,13‐tetraoxa‐7,16‐diazacyclooctadecane (DBDA18C6) as Sm3+ ionophore is reported. This potentiometric sensor showed a wide linear working range, 1×10?2–1×10?8 M, Nernstian slope, 20.2±0.48 mV per decade and a limit of detection, 6.3±0.36×10?9 M. It works in the pH range 2.5–8.5 and shows a good selectivity over a number of metal ions. It has been found suitable for the analysis of ores and industrial effluents. The electrode surface is characterized by FRA and AFM.  相似文献   

4.
A polyvinyl chloride (PVC) membrane based Pr(III) selective electrode was constructed using 1,6,7,12‐tetramine‐2,5,8,11‐tetraoxo‐1(12),6(7)‐di(biphenyl)dodecane (TATODBDD) as a neutral carrier. The sensor exhibits a Nernstian response for Pr(III) ions, a wide concentration range of 3.9×10?7?1.0×10?1 mol/L with a detection limit of 5.0×10?8 mol/L and slope of 19.5 mV/decade. The developed sensor revealed relatively good selectivity and high sensitivity for Pr(III) ions over the other lanthanide ions. The potentiometric response of the sensor is independent in the pH range 2.9–9.5. The advantages of sensor are low resistance, very fast response time (<10 s) with good selectivity. This sensor can be used up to 6 weeks without any divergences in potential response.  相似文献   

5.
《Electroanalysis》2006,18(16):1620-1626
A polyvinylchloride membrane sensor based on N,N′‐bis(salecylidene)‐1,2‐phenylenediamine (salophen) as membrane carrier was prepared and investigated as a Al3+‐selective electrode. The sensor exhibits a Nernstian response toward Al(III) over a wide concentration range (8.0×10?7–3.0×10?2 M), with a detection limit of 6.0×10?7 M. The potentiometric response of the sensor is independent of the pH of the test solution in the pH range 3.2–4.5. The electrode possesses advantages of very fast response and high selectivity for Al3+ in comparison with alkali, alkaline earth and some heavy metal ions. The sensor was used as an indicator electrode, in the potentiometric titration of aluminum ion and in determination of Al3+ contents in drug, water and waste water samples.  相似文献   

6.
A potentiometric sensor for lead(II) ions based on the use of 1,4,8,11‐tetrathiacyclotetradecane (TTCTD) as a neutral ionophore and potassium tetrakis‐(p‐chlorophenyl)borate as a lipophilic additive in plasticized PVC membranes is developed. The sensor exhibits linear potentiometric response towards lead(II) ions over the concentration range of 1.0×10?5–1.0×10?2 mol L?1 with a Nernstian slope of 29.9 mV decade?1 and a lower limit of detection of 2.2×10?6 mol L?1 Pb(II) ions over the pH range of 3–6.5. Sensor membrane without a lipophilic additive displays poor response. The sensor shows high selectivity for Pb(II) over a wide variety of alkali, alkaline earth and transition metal ions. The sensor shows long life span, high reproducibility, fast response and long term stability. Validation of the method by measuring the lower limit of detection, lower limit of linear range, accuracy, precision and sensitivity reveals good performance characteristics of the proposed sensor. The developed sensor is successfully applied to direct determination of lead(II) in real samples. The sensor is also used as an indicator electrode for the potentiometric titration of Pb(II) with EDTA and potassium chromate. The results obtained agree fairly well with data obtained by AAS.  相似文献   

7.
《Electroanalysis》2004,16(12):1002-1008
Preliminary theoretical studies revealed the selective complexation of bis (2‐mercaptoanil) diacetyl (BMDA) with La3+ over several alkali, alkaline earth and heavy metal ions. Thus, novel PVC‐based membrane (PBM) and coated graphite membrane (CGM) sensors for La(III) based on BMDA were prepared. The electrodes display Nernstian behavior over wide concentration ranges (i.e., 1.0×10?5–1.0×10?1 M for PBM and 1.0×10?6–1.0×10?1 M for CGM). The potential response of sensors was pH independent in the range of 4.0–8.0. The sensors possess satisfactory reproducibility, fast response time (<15 s), and specially excellent discriminating ability for La3+ ions with respect to most of the cations. The membrane sensor was used as an indicator electrode in potentiometric titration of lanthanum ions with EDTA. The coated graphite membrane electrode was applied in determination of fluoride ions in mouth wash preparations.  相似文献   

8.
《Electroanalysis》2005,17(24):2260-2265
A new Cu(II) ion‐selective PVC membrane sensor based on 6‐methyl‐4‐(1‐phenylmethylidene)amino‐3‐thioxo‐1,2,4‐triazin‐5‐one (MATTO) as an excellent sensing material was developed. The electrode exhibits a Nernstian slope of 29.2±0.4 mV per decade over a very wide concentration range between 1.0×10?1 and 1.0×10?6 M, with a detection limit of 4.8×10?7 M (30.5 ng/mL). The sensor possesses the advantages of short conditioning time, fast response time (<10 s), and especially, very good selectivity towards transition and heavy metal, and some mono, di and trivalent cations. The proposed electrode was successfully applied to the determination of copper in wastewater of copper electroplating samples and as an indicator electrode in potentiometric titration of Cu(II) ions with EDTA.  相似文献   

9.
In this work, a highly selective membrane triiodide sensor based on a new charge‐transfer complex of bis(2,4‐dimethoxybenzaldehyde)butane‐2,3‐dihydrazone with iodine (Iodide Charge Transfer complex: ICT) as membrane carrier is introduced. The influences of five different solvent mediators on sensitivity and selectivity of the proposed sensor were considered. The best performance was obtained with the membrane composition containing 30% poly (vinyl chloride), 63% DBP, 5% ICT and 2% HTAB. The electrode shows a Nernstian behavior over a very wide triiodide ion concentration range (1.0 × 10?7‐1.0 × 10?2 M), and a detection limit value of 8.0 × 10?8 M. The effect of pH on the potentiometric response of the sensor was also studied, and it was found that the response of the electrode is independent of the pH of the solution in the pH range of 4.0–10. The proposed sensor has a very fast response time (< 12 s), and good selectivities relative to a wide variety of common inorganic and organic anions, including iodide, acetate, bromide, chloride, fluoride, nitrite, nitrate, sulfite, sulfate, cyanide and thiocyanate. In fact the selectivity behavior of the proposed triiodide ion‐selective electrode shows great improvements compared to the previously reported electrodes for triiodide ion. The proposed membrane sensor can be used for at least 6 months without any divergence in the potentials. The electrode was successfully applied as an indicator electrode in the titration of triiodide with thiosulfate ion.  相似文献   

10.
《Electroanalysis》2004,16(21):1771-1776
In this work a dysprosium [Dy(III)]‐selective solvent polymeric membrane sensor based on N,N‐bis(pyrrolidene) benzne‐1,2‐diamine, poly(vinyl chloride)(PVC), the plasticizer benzylacetate (BA), and anionic site is described. This sensor responds to Dy(III) activity in a linear range from 1.0×10?5 to 1.0×10?1 M, with a slope of 20.6±0.2 mV per decade and a detection limit of 6.0×10?6 M at the pH range of 3.5–8.0. It has a fast response time of<20 s in the entire concentration range, and can be used for at least 2 months without any considerable divergence in the electrode potentials. The proposed sensor revealed comparatively good selectivity with respect to common alkali, alkaline earth, transition and heavy metal ions. It was used as an indicator electrode in the potentiometric titration of fluoride ions and in determination of concentration of F ions in some mouth washing solutions.  相似文献   

11.
A new modified carbon paste electrode (CPE) based on a recently synthesized ligand [2‐mercapto‐5‐(3‐nitrophenyl)‐1,3,4‐thiadiazole] (MNT), self‐assembled to gold nanoparticles (GNP) as suitable carrier for Cd(II) ion with potentiometric method are described. The proposed electrode exhibits a Nernstian slope of 29.4±1.0 mV per decade for Cd(II) ion over a wide concentration range from 3.1×10?8 to 3.1×10?4 mol L?1. The detection limit of electrode was 2.0×10?8 mol L?1 of cadmium ion. The potentiometric responses of electrode based on MNT is independent of the pH of test solution in the pH range 2.0–4.0. It has quick response with response time of about 6 s. The proposed electrode show fairly good selectivity over some alkali, alkaline earth, transition and heavy metal ions. Finally, the proposed electrode was successfully employed to detect Cd(II) ion in hair and water samples.  相似文献   

12.
A novel membrane sensor for selective monitoring of iodide, consisting of a triiodide‐ketoconazole ion pair complex dispersed in a PVC matrix, plasticized with a mixture of 2‐nitrophenyl octyl ether and dioctylphtalate with unique selectivity toward iodide ions, is described. The influence of membrane composition, pH of test solution and foreign ions on the electrode performance were investigated. The optimized membrane demonstrates a near‐Nernstian response for iodide ions over a wide linear range from 1.0 × 10?2 to 1.0 × 10?5 M, at 25 ± 1 °C. The electrode could be used over a wide pH range 3–10 and has the advantages of high selectivity, fast response time and good lifetime (over 4 months). It was successfully used as indicator electrode in potentiometric titrations and direct potentiometric assay of iodide ions.  相似文献   

13.
《Electroanalysis》2002,14(23):1621-1628
Copper phthalocyanine was used as ion carrier for preparing polymeric membrane selective sensor for detection of iodide. The electrode was prepared by incorporating the ionophore into plasticized poly(vinyl chloride) (PVC) membrane, coated on the surface of graphite electrode. This novel electrode shows high selectivity for iodide with respect to many common inorganic and organic anions. The effects of membrane composition, pH and the influence of lipophilic cationic and anionic additives and also nature of plasticizer on the response characteristics of the electrode were investigated. A calibration plot with near‐Nernestian slope for iodide was observed over a wide linear range of five decades of concentration (5×10?6?1×10?1 M). The electrode has a fast response time, and micro‐molar detection limit (ca. 1×10?6 M iodide) and could be used over a wide pH range of 3.0–8.0. Application of the electrode to the potentiometric titration of iodide ion with silver nitrate is reported. This sensor is used for determination of the minute amounts of iodide in lake water samples.  相似文献   

14.
《Electroanalysis》2006,18(10):1019-1027
A new PVC membrane potentiometric sensor for Ag(I) ion based on a recently synthesized calix[4]arene compound of 5,11,17,23‐tetra‐tert‐butyl‐25,27‐dihydroxy‐calix[4]arene‐thiacrown‐4 is developed. The electrode exhibits a Nernstian response for Ag(I) ions over a wide concentration range (1.0×10?2?1.0×10?6 M) with a slope of 53.8±1.6 mV per decade. It has a relatively fast response time (5–10 s) and can be used for at least 2 months without any considerable divergence in potentials. The proposed electrode shows high selectivity towards Ag+ ions over Pb2+, Cd2+, Co2+, Zn2+, Cu2+, Ni2+, Sr2+, Mg2+, Ca2+, Li+, K+, Na+, NH4+ ions and can be used in a pH range of 2–6. Only interference of Hg2+ is found. It is successfully used as an indicator electrode in potentiometric titration of a mixture of chloride, bromide and iodide ions.  相似文献   

15.
《Electroanalysis》2005,17(22):2032-2036
We found that bis(thiophenal) pyridine‐2,6‐diamine (BPD) can be used as an excellent ion carrier to prepare a gadolinium‐selective PVC‐based membrane sensor. The use of oleic acid (OA) and potassium tetrakis(p‐chlorophenyl borate)(KTKpClPB), as anionic additives, and dibutyl phthalate (DBP), acetophenone (AP) and nitrobenzene (NB), as plasticizing solvent mediators was investigated. The best performance was observed with a membrane having the composition of 30% PVC; 62% BA; 5% BPD; and 3% KTKpClPB. The resulting sensor works well over a relatively wide concentration range (1.0×10?6–1.0×10?1 M) with a Nernstian slope of 19.4±0.4 mV per decade of gadolinium activity over a wide pH range (3.5–8.0). The limit of detection of the sensor is 7.0×10?7 M (ca. 110 ng mL?1). The proposed electrode shows excellent discriminating ability toward gadolinium ions with regard to common alkali, alkaline earth, transition, heavy metal ions, and specially, lanthanide ions. The proposed sensor was applied as an indicator electrode for titration of gadolinium ions with EDTA.  相似文献   

16.
《Electroanalysis》2003,15(19):1561-1565
A highly selective membrane electrode for the determination of ultratrace amounts of lead was prepared. The PVC membrane electrode based on 2‐(2‐ethanoloxymethyl)‐1‐hydroxy‐9,10‐anthraquinone (AQ), directly coated on graphite, exhibits a good Nernstian response for Pb(II) ions over a very wide concentration range (1.0×10?7–1.0×10?2 M) with a limit of detection of 8.0×10?8 M. It has a fast response time of ca. 10 s and can be used over a period 2 months with good reproducibility (SD=±0.2 mV). The electrode revealed a very good selectivity respect to common alkali, alkaline earth, transition and heavy metal ions and could be used in the pH range of 3.5–6.8. It was used as an indicator electrode in potentiometric titration of lead ions with chromate and oxalate, and in indirect determination of lead in spring water samples.  相似文献   

17.
The potentiometric characteristics of a new Cu2+‐selective electrode based on 2‐(benzyliminomethyl)‐6‐methoxy‐4‐(4‐methoxyphenyl‐azo) phenol as an efficient ionophore has been evaluated. The effects of influential parameters on the potentiometric responses such as the amount of plasticizer, the amount of ionophore, pH of the sample solution, and the effect of coexisting ions on the electrode signal were subsequently investigated . The selectivity of the electrode was assessed by calculating the selectivity coefficients using the matched potential method. The optimum ratio of the amount of materials required for the preparation of the electrode was found to be 1.7: 32.1: 64.2: 2.0 corresponding to carboxylated PVC, dimethyl sebacate as solvent mediators, potassium tetrakis (p‐chlorophenyl) borate as the anion localizing agent, and ionophore, respectively. The electrode had a fast response (7s) as well as a satisfactory Nernstian slope (29.26±0.91 mV/decade) to Cu2+ over a wide concentration range of 2.0×10?6‐ 5.0×10?2 M with a low detection limit of 5.9×10?7 M. The developed sensor was successfully used for the potentiometric titration of Cu2+ ion with EDTA and subsequently, efficient determination of this metal ion in a mineral water sample was performed.  相似文献   

18.
A new chromium(III) PVC membrane sensor incorporating ptertiary‐butyl calix[4]arene as ionophore, potassium tetrakis as additive and dibutyl phthalate (DBP) as plasticizer was constructed. The electrode exhibited an excellent potentiometric response over a wide concentration range of 1.0×10?7–1.0×10?1 M with a Nernstian slope of 20±0.5 mV per decade. The detection limit was 5.0×10?8 M. The electrode showed a better performance over a pH range of 3.0–8.0, and had a short response time of about <15 s.The electrode was successfully applied to potentiometric titration of Cr (III) with EDTA and for direct determination of chromium(III) in waste water.  相似文献   

19.
《Electroanalysis》2005,17(20):1828-1834
A recently synthesized azao‐containing Schiff's base N,N′‐adipylbis(5‐phenylazo salicylaldehyde hydrazone) was used as a suitable neutral ion carrier in construction of a highly selective La3+‐PVC membrane electrode. The electrode exhibits a Nernstian response with a slope of 19.4 mV decade?1 over a wide concentration range (1.0×10?6–1.0×10?2 M) and a limit of detection of 4.0×10?7 M (0.05 ppm). The electrode possesses a fast response time of ca. 10 s and can be used for at least 3 months without observing any deviation. The proposed electrode revealed excellent selectivity for La3+ over a wide variety of alkali, alkaline earth, transition and heavy metal ions and could be used in a pH range of 4.0–8.0. The practical utility of the electrode has been demonstrated by its use as an indicator electrode in the potentiometric titration of La3+ ions with EDTA and in determination of F? ion in some pharmaceutical preparations.  相似文献   

20.
《Electroanalysis》2005,17(17):1534-1539
The construction, performance, and applications of a novel ytterbium(III) sensor based on N‐(2‐pyridyl)‐N′‐(2‐methoxyphenyl)‐thiourea (PMT), as an excellent carrier, in plasticized poly(vinyl chloride) PVC matrix, is described. The influences of membrane composition and pH on the potentiometric response of the sensor were investigated. The sensor exhibits a nice Nernstian response for Yb(III) ion over a wide concentration range of 4 decades of concentration (1.0×10?6–1.0×10?2 M), and a detection limit of 5.0×10?7 M. The response time of the electrodes is between 8 and 10 s, depending on the concentration of ytterbium(III) ions. The proposed sensor can be used for about 8 weeks without any considerable divergence in potential. The sensor revealed very good selectivity for Yb(III) in the presence of several metal ions. The best performance was observed for the membrane containing; 30% PVC, 59% o‐nitrophenyloctyl ether (NPOE) as solvent mediator, 7% PMT, and 4% sodium tetraphenyl borate (NaTPB). It was successfully applied as indicator electrodes in the potentiometric titration of Yb(III) with EDTA and for the determination of fluoride ion in two mouth wash formulations. The proposed La(III) sensor was found to work well under laboratory conditions. It was also used as an indicator electrode in titration of a 1.0×10?4 M of Yb(III) with a standard EDTA solution (1.0×10?2 M). It was also used for determination of Yb(III) ion in Xenotime .  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号