首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A new Fourier transform ion cyclotron resonance (FTICR) cell based on completely new principles of formation of the effective electric potential distribution in Penning type traps, Boldin and Nikolaev (Proceedings of the 58th ASMS Conference, 2010), Boldin and Nikolaev (Rapid Commun Mass Spectrom 25:122–126, 2011) is constructed and tested experimentally. Its operation is based on the concept of electric potential space-averaging via charged particle cyclotron motion. Such an averaging process permits an effective electric force distribution in the entire volume of a cylindrical Penning trap to be equal to its distribution in the field created by hyperbolic electrodes in an ideal Penning trap. The excitation and detection electrodes of this new cell are shaped for generating a quadratic dependence on axial coordinates of an averaged (along cyclotron motion orbit) electric potential at any radius of the cyclotron motion. These electrodes together with the trapping segments form a cylindrical surface like in a conventional cylindrical cell. In excitation mode this cell being elongated behaves almost like an open cylindrical cell of the same length. It is more effective in ion motion harmonization at larger cyclotron radii than a Gabrielse et al.-type (Int J Mass Spectrom Ion Processes 88:319–332, 1989) cylindrical cell with four compensation sections. A mass resolving power of more than twenty millions of reserpine (m/z 609) and more than one million of highly charged BSA molecular ions (m/z 1357) has been obtained in a 7T magnetic field.  相似文献   

2.
A recently described ion charge coupled device detector IonCCD (Sinha and Wadsworth, Rev. Sci. Instrum. 76(2), 2005; Hadjar, J. Am. Soc. Mass Spectrom. 22(4), 612–624, 2011) is implemented in a miniature mass spectrometer of sector-field instrument type and Mattauch-Herzog (MH)-geometry (Rev. Sci. Instrum. 62(11), 2618–2620, 1991; Burgoyne, Hieftje and Hites J. Am. Soc. Mass Spectrom. 8(4), 307–318, 1997; Nishiguchi, Eur. J. Mass Spectrom. 14(1), 7–15, 2008) for simultaneous ion detection. In this article, we present first experimental evidence for the signature of energy loss the detected ion experiences in the detector material. The two energy loss processes involved at keV ion kinetic energies are electronic and nuclear stopping. Nuclear stopping is related to surface modification and thus damage of the IonCCD detector material. By application of the surface characterization techniques atomic force microscopy (AFM) and X-ray photoelectrons spectroscopy (XPS), we could show that the detector performance remains unaffected by ion impact for the parameter range observed in this study. Secondary electron emission from the (detector) surface is a feature typically related to electronic stopping. We show experimentally that the properties of the MH-mass spectrometer used in the experiments, in combination with the IonCCD, are ideally suited for observation of these stopping related secondary electrons, which manifest in reproducible artifacts in the mass spectra. The magnitude of the artifacts is found to increase linearly as a function of detected ion velocity. The experimental findings are in agreement with detailed modeling of the ion trajectories in the mass spectrometer. By comparison of experiment and simulation, we show that a detector bias retarding the ions or an increase of the B-field of the IonCCD can efficiently suppress the artifact, which is necessary for quantitative mass spectrometry.  相似文献   

3.
In this paper, we first recall some known architectures of polyhedral links (Qiu and Zhai in J Mol Struct (THEOCHEM) 756:163–166, 2005; Yang and Qiu in MATCH Commun Math Comput Chem 58:635–646, 2007; Qiu et al. in Sci China Ser B Chem 51:13–18, 2008; Hu et al. in J Math Chem 46:592–603, 2009; Cheng et al. in MATCH Commun Math Comput Chem 62:115–130, 2009; Cheng et al. in MATCH Commun Math Comput Chem 63:115–130, 2010; Liu et al. in J Math Chem 48:439–456 2010). Motivated by these architectures we introduce the notions of polyhedral links based on edge covering, vertex covering, and mixed edge and vertex covering, which include all polyhedral links in Qiu and Zhai (J Mol Struct (THEOCHEM) 756:163–166, 2005), Yang and Qiu (MATCH Commun Math Comput Chem 58:635–646, 2007), Qiu et al. (Sci China Ser B Chem 51:13–18, 2008), Hu et al. (J Math Chem 46:592–603, 2009), Cheng et al. (MATCH Commun Math Comput Chem 62:115–130, 2009), Cheng et al. (MATCH Commun Math Comput Chem 63:115–130, 2010), Liu et al. (J Math Chem 48:439–456, 2010) as special cases. The analysis of chirality of polyhedral links is very important in stereochemistry and the Jones polynomial is powerful in differentiating the chirality (Flapan in When topology meets chemistry. Cambridge Univ. Press, Cambridge, 2000). Then we give a detailed account of a result on the computation of the Jones polynomial of polyhedral links based on edge covering developed by Jin, Zhang, Dong and Tay (Electron. J. Comb. 17(1): R94, 2010) and, at the same time, by using this method we obtain some new computational results on polyhedral links of rational type and uniform polyhedral links with small edge covering units. These new computational results are helpful to judge the chirality of polyhedral links based on edge covering. Finally, we give some remarks and pose some problems for further study.  相似文献   

4.
A radio frequency-free electromagnetostatic (EMS) cell devised for electron-capture dissociation (ECD) of ions has been retrofitted into the collision-induced dissociation (CID) section of a triple quadrupole mass spectrometer to enable recording of ECD product-ion mass spectra and simultaneous recording of ECD-CID product-ion mass spectra. This modified instrument can be used to produce easily interpretable ECD and ECD-CID product-ion mass spectra of tyrosine-phosphorylated peptides that cover over 50% of their respective amino-acid sequences and readily identify their respective sites of phosphorylation. ECD fragmentation of doubly protonated, tyrosine-phosphorylated peptides, which was difficult to observe with FT-ICR instruments, occurs efficiently in the EMS cell. Figure
?  相似文献   

5.
A Fourier-transform ion cyclotron resonance (FT-ICR) top-down mass spectrometry strategy for determining the adenosine triphosphate (ATP)-binding site on chicken adenylate kinase is described. Noncovalent protein-ligand complexes are readily detected by electrospray ionization mass spectrometry (ESI-MS), but the ability to detect protein-ligand complexes depends on their stability in the gas phase. Previously, we showed that collisionally activated dissociation (CAD) of protein-nucleotide triphosphate complexes yield products from the dissociation of a covalent phosphate bond of the nucleotide with subsequent release of the nucleotide monophosphate (Yin, S. et al., J. Am. Soc. Mass Spectrom. 2008, 19, 1199–1208). The intrinsic stability of electrostatic interactions in the gas phase allows the diphosphate group to remain noncovalently bound to the protein. This feature is exploited to yield positional information on the site of ATP-binding on adenylate kinase. CAD and electron capture dissociation (ECD) of the adenylate kinase-ATP complex generate product ions bearing monoand diphosphate groups from regions previously suggested as the ATP-binding pocket by NMR and crystallographic techniques. Top-down MS may be a viable tool to determine the ATP-binding sites on protein kinases and identify previously unknown protein kinases in a functional proteomics study.  相似文献   

6.
7.
Previously, we have indicated (Cooper, H.J., et al. Int. J. Mass Spectrom., 2003, 228, 723-728) that electron capture dissociation (ECD) of the doubly protonated peptides, Leu(4)-Sar-Leu(3)-Lys-OH, Leu(4)-Ala-Leu(3)-Lys-OH, Gly(4)-Sar-Gly(3)-Lys-NH(2), and Gly(3)-Pro-Sar-Gly(3)-Lys-NH(2), results in abundant b ions, which derive from fragmentation of backbone amide bonds, a nonstandard fragmentation channel in ECD. The instrumental conditions were such that the possibility that collision-induced dissociation processes were contributing to the observed spectra was eliminated. In a separate study (Fung, Y.M.E., et al. Eur. J. Mass Spectrom., 2004, 10, 449-457. ECD of peptides Arg-(Gly)(n)-Xxx-(Gly)(n)-Arg, where Xxx is the amino acid of interest, did not result in b ions. The variation in ECD observed for strikingly similar peptides suggests that the nature of the charge carrier (Arg or Lys) is instrumental in governing the fragmentation channels. Here, we describe the ECD behavior of a suite of model peptides designed such that the nature and position of the charge carrier could be probed. The results suggest that the presence of b ions in ECD spectra is a consequence of both charge carrier and peptide structure. Possible mechanisms for the formation of b ions following electron capture are discussed.  相似文献   

8.
The effective use of pencil as a matrix for matrix-assisted laser desorption/ionisation (MALDI) for the study of actinides has previously been demonstrated (Black et al., Rapid Commun. Mass Spectrom. 2006; 20: 1053). Here, the scope of the types of molecules amenable to analysis by this method has been extended, establishing that approximately 90% of a library containing 50 diverse small molecules can be successfully analysed by this technique. Further, the role played by the bulk materials present in the different pencil leads has been investigated and a simple one-step deposition of matrix and calibration materials has been achieved through the fabrication of different calibration pencils (Cali-Pens).  相似文献   

9.
The fragmentation reactions of the protonated dipeptides Gly-Arg and Arg-Gly have been studied using collision-induced dissociation (CID) in a quadrupole ion trap, by in-source CID in a single-quadrupole mass spectrometer and by CID in the quadrupole cell of a QqTOF mass spectrometer. In agreement with earlier quadrupole ion trap studies (Farrugia, J. M.; O'Hair, R. A. J., Int. J. Mass Spectrom., 2003, 222, 229), the CID mass spectra obtained with the ion trap for the MH(+) ions and major fragment ions are very similar for the two isomers indicating rearrangement to a common structure before fragmentation. In contrast, in-source CID of the MH(+) ions and QqTOF CID of the MH(+), [MH - NH(3)](+) and [MH <23 HN = C(NH(2))(2)](+) ions provide distinctly different spectra for the isomeric dipeptides, indicating that rearrangement to a common structure has not occurred to a significant extent under these conditions even near the threshold for fragmentation in the QqTOF instrument. Clearly, under normal operating conditions significantly different fragmentation behavior is observed in the ion trap and beam-type experiments. This different behavior probably can be attributed to the shorter observation times and concomitant higher excitation energies in the in-source and QqTOF experiments compared to the long observation times and lower excitation energies relevant to the ion trap experiments. Based largely on elemental compositions derived from accurate mass measurements in QqTOF studies fragmentation schemes are proposed for the MH(+), [MH - NH(3)](+), and [MH - (HN = C(NH(2))(2))](+) ions.  相似文献   

10.
We report on the preliminary testing of a new position-sensitive detector (PSD) by combining a microchannel plate (MCP) and a charge-sensitive pixilated anode with a direct readout based on charge-coupled detector (CCD) technology, which will be referred to as IonCCD (Hadjar et al. J Am Soc Mass Spectrom 22(4):612–623, 2011; Johnson et al. J Am Soc Mass Spectrom 22(8):1388–1394, 2011; Hadjar et al. J Am Soc Mass Spectrom 22(10):1872–1884, 2011). This work exploits the recently discovered electron detection capability of the IonCCD (Hadjar et al. J Am Soc Mass Spectrom 22(4):612–623, 2011), allowing it to be used directly behind an MC. This MCP-IonCCD configuration potentially obviates the need for electro-optical ion detector systems (EOIDs), which typically feature a relatively difficult-to-implement 5-kV power source as well as a phosphorus screen behind the MCP for conversion of electrons to photons prior to signal generation in a photosensitive CCD. Thus, the new system (MCP-IonCCD) has the potential to be smaller, simpler, more robust, and more cost efficient than EOID-based technologies in many applications. The use of the IonCCD as direct MCP readout anode, as opposed to its direct use as an ion detector, will benefit from the instant three-to-four-order-of-magnitude gain of the MCP with virtually no additional noise. The signal/noise gain can be used for either sensitivity or speed enhancement of the detector. The speed enhancement may motivate the development of faster IonCCD readout speeds (currently at 2.7 ms) to achieve the 2 kHz frame rate for which the IonCCD chip was designed, a must for transient signal applications. The presented detector exhibits clear potential not only as a trace analysis detector in scan-free mass spectrometry and electron spectroscopy but also as a compact detector for photon and particle imaging applications.  相似文献   

11.
Several stable and storable anticoagulant rodenticides involving both merits of acute and chronic rodenticides have been synthesized (Holbrook et al. in Arch Intern Med 165:1095–1106, 2005; Baglin et al. in Br J Haematol 132:277–285, 2006). The structures of synthesized compounds were confirmed by IR, 1H NMR. The compounds were also evaluated for their anticoagulant and acute biologic activity (Lipton et al., JAMA 252:3004–3005, 3).  相似文献   

12.
Product ion spectra produced by collision-induced dissociation (CID) in tandem mass spectrometry experiments can differ markedly between instruments. There have been a number of attempts to standardise the production of product ion spectra; however, a consensus on the most appropriate approach to the reproducible production of spectra has yet to be reached. We have previously reported the comparison of product ion spectra on a number of different types of instruments - a triple quadrupole, two ion traps and a Fourier transform ion cyclotron resonance mass spectrometer (Bristow AWT, Webb KS, Lubben AT, Halket JM. Rapid Commun. Mass Spectrom. 2004; 18: 1). The study showed that a high degree of reproducibility was achievable. The goal of this study was to improve the comparability and reproducibility of CID product ion mass spectra produced in different laboratories and using different instruments. This was carried out experimentally by defining a spectral calibration point on each mass spectrometer for product ion formation. The long-term goal is the development of a universal (instrument independent) product ion mass spectral library for the identification of unknowns.The spectra of 48 compounds have been recorded on eleven mass spectrometers: six ion traps, two triple quadrupoles, a hybrid triple quadrupole, and two quadrupole time-of-flight instruments. Initially, 4371 spectral comparisons were carried out using the data from eleven instruments and the degree of reproducibility was evaluated. A blind trial has also been carried out to assess the reproducibility of spectra obtained during LC/MS/MS.The results suggest a degree of reproducibility across all instrument types using the tuning point technique. The reproducibility of the product ion spectra is increased when comparing the tandem in time type instruments and the tandem in space instruments as two separate groups. This may allow the production of a more limited, yet useful, screening library for LC/MS/MS identification using instruments of the same type from different manufacturers.  相似文献   

13.
The new method of analysis of relative isotopologue abundances (ARIA) applied here is based on the evaluation of total isotope patterns of tryptic protein fragments measured by matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOFMS) to calculate the mixing ratios of composites consisting of stable isotope labelled and isotopically natural (unlabelled) proteins, as described in an accompanying paper in this issue. Recently, Sechi (Rapid Commun. Mass Spectrom. 2002; 16: 1416-1424) and Gehanne et al. (Rapid Commun. Mass Spectrom. 2002; 16: 1692-1698) introduced the use of differential quantitative mass analysis by MALDI-TOFMS using mixtures of standard proteins alkylated prior to two-dimensional polyacrylamide gel electrophoresis (2D-PAGE) with either acrylamide (AA) or deuterium-labelled [2,3,3'-D(3)]-acrylamide (D3AA). In the present study we validate the AA/D3AA system, firstly by measuring the yield of proteins alkylated with AA, and secondly by using differential radioactive labels ((125)I and (131)I) to quantitatively establish that non-comigration in 2D-PAGE is negligible. ARIA is then applied to quantitatively estimate the relative proportions of peptides labelled with AA or D3AA in the validated system, using typical silver-stained 2D-PAGE protein spots from 2D gels loaded with 150 microg of total liver protein. The precision and limitations of ARIA quantification of peptides differentially alkylated with isotopomeric reagents are discussed.  相似文献   

14.
The structure of the a 4 ion from protonated YGGFL was studied in a quadrupole ion trap mass spectrometer by ‘action’ infrared spectroscopy in the 1000–2000 cm–1 (‘fingerprint’) range using the CLIO Free Electron Laser. The potential energy surface (PES) of this ion was characterized by detailed molecular dynamics scans and density functional theory calculations exploring a large number of isomers and protonation sites. IR and theory indicate the a 4 ion population is primarily populated by the rearranged, linear structure proposed recently (Bythell et al., J. Am. Chem. Soc. 2010, 132, 14766). This structure contains an imine group at the N- terminus and an amide group –CO–NH2 at the C-terminus. Our data also indicate that the originally proposed N-terminally protonated linear structure and macrocyclic structures (Polfer et al., J. Am. Chem. Soc. 2007, 129, 5887) are also present as minor populations. The clear differences between the present and previous IR spectra are discussed in detail. This mixture of gas-phase structures is also in agreement with the ion mobility spectrum published by Clemmer and co-workers recently (J. Phys. Chem. A 2008, 112, 1286). Additionally, the calculated cross-sections for the rearranged structures indicate these correspond to the most abundant (and previously unassigned) feature in Clemmer’s work.  相似文献   

15.
We report the use of paper-based microfluidic devices fabricated from a novel polymer blend for the monitoring of urinary ketones, glucose, and salivary nitrite. Paper-based devices were fabricated via photolithography in less than 3 min and were immediately ready for use for these diagnostically relevant assays. Patterned channels on filter paper as small as 90 μm wide with barriers as narrow as 250 μm could be reliably patterned to permit and block fluid wicking, respectively. Colorimetric assays for ketones and nitrite were adapted from the dipstick format to this paper microfluidic chip for the quantification of acetoacetate in artificial urine, as well as nitrite in artificial saliva. Glucose assays were based on those previously demonstrated (Martinez et al., Angew Chem Int Ed 8:1318–1320, 1; Martinez et al., Anal Chem 10:3699–3707, 2; Martinez et al., Proc Nat Acad Sci USA 50:19606–19611, 3; Lu et al., Electrophoresis 9:1497–1500, 4; Abe et al., Anal Chem 18:6928–6934, 5). Reagents were spotted on the detection pad of the paper device and allowed to dry prior to spotting of samples. The ketone test was a two-step reaction requiring a derivitization step between the sample spotting pad and the detection pad, thus for the first time, confirming the ability of these paper devices to perform online multi-step chemical reactions. Following the spotting of the reagents and sample solution onto the paper device and subsequent drying, color images of the paper chips were recorded using a flatbed scanner, and images were converted to CMYK format in Adobe Photoshop CS4 where the intensity of the color change was quantified using the same software. The limit of detection (LOD) for acetoacetate in artificial urine was 0.5 mM, while the LOD for salivary nitrite was 5 μM, placing both of these analytes within the clinically relevant range for these assays. Calibration curves for urinary ketone (5 to 16 mM) and salivary nitrite (5 to 2,000 μM) were generated. The time of device fabrication to the time of test results was about 25 min.  相似文献   

16.
Oxidized nucleosides are biochemical markers for tumors, aging, and neurodegenerative diseases. However, during the last decade, the analytical methods for nucleosides by gas chromatography/mass spectrometry (GC/MS) and high-performance liquid chromatography (HPLC) with single-parameter detectors like electron-capture detection (ECD) have not been sufficiently rapid or reliable to detect nucleosides in urine and to analyze clinical samples. It has been reported (Dudley et al., Rapid Commun Mass Spectrom. 2000; 14: 1200) that liquid chromatography with electrospray mass spectrometry (LC/ESI-MS) is more specific and sensitive for analysis of nucleosides than HPLC with conventional detectors; however, this method required complex extraction steps. In the present work a direct LC/ESI-MS method for nucleosides without extraction of urine samples has been developed. Analysis of nucleosides using positive-ion mode with selected reaction monitoring effectively eliminated potential interferences from endogenous constituents of the urine. This highly selective and sensitive method made it possible to analyze urinary nucleosides with a lower limit of quantitation of 0.2 nmol/mL. The method has been validated, with both excellent linearity and reproducibility, in the calibration range from 0.2-400 nmol/mL. The correlation coefficients of the calibration curves were higher than 0.987. The coefficients of variation were in the range 0.03-14.92% (inter-day) and 0.54-14.39% (intra-day), respectively.  相似文献   

17.
An improved method to interpret triple quadrupole MS/MS experiments of complexes of large ions is presented and applied to a study of the complex formed by the proteins cytochrome c and cytochrome b5. Modeling of the activation and dissociation process shows that most of the reaction occurs near the collision cell exit where ions have the highest internal energies. Experiments at different collision cell pressures or with different collision gases (Ne, Ar, Kr) are interpreted with a previously proposed collision model (Chen et al., Rapid Commun. Mass Spectrom. 1998, 12, 1003-1010) to calculate the internal energy added to ions to cause dissociation. Small but systematic differences under different experimental conditions are attributed to different times available for reaction. A method to correct for this is presented. Ne, Ar, and Kr are found to have similar energy transfer efficiencies. Complexes of cytochrome c and cytochrome b5 are detected in ESI mass spectra but with abundances less than expected from the solution equilibrium. Dissociation of the cytochrome c-cytochrome b5 complexes with charge k gives as the most abundant fragments, cytochrome b5(+3) and cytochrome c+(k-3). Adding charges to the complex destabilizes it. A series of cytochrome c variants with Lys residues thought to be involved in solution binding replaced by Ala showed no differences in the energy required to induce dissociation of the gas phase complex. The implications for the binding of the gas phase ions are inconclusive.  相似文献   

18.
Normal-phase high-performance liquid chromatography (NP-HPLC) coupled to atmospheric pressure ionization mass spectrometry (APCI-MS) allows quantitative analysis of endogenous ceramide and dihydroceramide species from crude lipid extracts. Qualitative information for the species comes from observation of differences in chromatographic and mass spectrometric behavior between species (Pettus et al. Rapid Commun. Mass Spectrom. 2003; 17: 1017-1026). Quantitative analysis is achieved by (1) use of a synthetic internal standard as an extraction and injection control, (2) lack of salt adduction, ion suppression, or other matrix effects in APCI mode, and (3) consistent fragmentation and ionization of external standards across the physiologically relevant concentration range found in endogenous lipid samples. Application to the analysis and quantitation of ceramide and dihydroceramide from various cell lines is demonstrated. The results from APCI-MS analysis corroborate and enhance information acquired from use of the diacylglycerol kinase assay for total ceramide measurement. This technique readily allows simultaneous quantitation of ceramide and dihydroceramide species.  相似文献   

19.
The dissociation behavior of phosphorylated and sulfonated peptide anions was explored using metastable atom-activated dissociation mass spectrometry (MAD-MS) and collision-induced dissociation (CID). A beam of high kinetic energy helium (He) metastable atoms was exposed to isolated phosphorylated and sulfonated peptides in the 3– and 2– charge states. Unlike CID, where phosphate losses are dominant, the major dissociation channels observed using MAD were Cα – C peptide backbone cleavages and neutral losses of CO2, H2O, and [CO2 + H2O] from the charge reduced (oxidized) product ion, consistent with an electron detachment dissociation (EDD) mechanism such as Penning ionization. Regardless of charge state or modification, MAD provides ample backbone cleavages with little modification loss, which allows for unambiguous PTM site determination. The relative abundance of certain fragment ions in MAD is also demonstrated to be somewhat sensitive to the number and location of deprotonation sites, with backbone cleavage somewhat favored adjacent to deprotonated sites like aspartic acid residues. MAD provides a complementary dissociation technique to CID, ECD, ETD, and EDD for peptide sequencing and modification identification. MAD offers the unique ability to analyze highly acidic peptides that contain few to no basic amino acids in either negative or positive ion mode.  相似文献   

20.
The electron capture dissociation (ECD) of metallo-supramolecular dinuclear triple-stranded helicate Fe2L34+ ions was determined by Fourier transform ion cyclotron resonance mass spectrometry. Initial electron capture by the di-iron(II) triple helicate ions produces dinuclear double-stranded complexes analogous to those seen in solution with the monocationic metal centers CuI or AgI. The gas-phase fragmentation behavior [ECD, collision-induced dissociation (CID), and infrared multiphoton dissociation (IRMPD)] of the di-iron double-stranded complexes, (i.e., MS3 of the ECD product) was compared with the ECD, CID, and IRMPD of the CuI and AgI complexes generated from solution. The results suggest that iron-bound dimers may be of the form Fe2IL22+ and that ECD by metallo-complexes allows access, in the gas phase, to oxidation states and coordination chemistry that cannot be accessed in solution.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号