首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Flow boiling heat transfer in a vertical spirally internally ribbed tube   总被引:3,自引:0,他引:3  
 Experiments of flow boiling heat transfer and two-phase flow frictional pressure drop in a spirally internally ribbed tube (φ22×5.5 mm) and a smooth tube (φ19×2 mm) were conducted, respectively, under the condition of 6×105 Pa (absolute atmosphere pressure). The available heated length of the test sections was 2500 mm. The mass fluxes were selected, respectively, at 410, 610 and 810 kg/m2 s. The maximum heat flux was controlled according to exit quality, which was no more than 0.3 in each test run. The experimental results in the spirally internally ribbed tube were compared with that in the smooth tube. It shows that flow boiling heat transfer coefficients in the spirally internally ribbed tube are 1.4–2 times that in the smooth tube, and the flow boiling heat transfer under the condition of smaller temperature differences can be achieved in the spirally internally ribbed tube. Also, the two-phase flow frictional pressure drop in the spirally internally ribbed tube increases a factor of 1.6–2 as compared with that in the smooth tube. The effects of mass flux and pressure on the flow boiling heat transfer were presented. The effect of diameters on flow boiling heat transfer in smooth tubes was analyzed. Based on the fits of the experimental data, correlations of flow boiling heat transfer coefficient and two-phase flow frictional factor were proposed, respectively. The mechanisms of enhanced flow boiling heat transfer in the spirally internally ribbed tube were analyzed. Received on 1 December 1999  相似文献   

2.
Performance of horizontal copper heaters with a transverse fin structure was investigated for pool boiling heat transfer and critical heat flux limits. Data were obtained for 5.1 and 7.6 cm diameter structured cooper and brass heaters in saturated R-113 boiling at pressures ranging between 0.037 and 1 atm. The fin structure consisted of 0.16 cm×0.16 cm×0.32 cm high square fins with an interfin spacing of 0.16 cm. Following a similar methodology to Haley and Westwater1, a numerical analysis of the heat transfer phenomenon was performed by solving the one-dimensional fin conduction equation with a non-linear heat transfer boundary condition obtained from the previously reported data for R-113 boiling on plain surfaces. The predictions agreed with the data at the 1 atm pressure levels but showed deviations at the low pressure levels. The results showed that, compared with plain surface heaters of the same diameters the finned structured surfaces investigated: (a) decreased the wall temperature differences for a given heat flux and saturated pool boiling conditions, thus improving the nucleate boiling heat transfer coefficients, and (b) increased the critical heat flux limits, calculated as the power input divided by the heater projected area, by a factor of 2–2.5.  相似文献   

3.
A systematic comparison was made between the forced convection heat transfer characteristics of the supercritical pressure water and that of the subcritical pressure water in vertically-upward tubes. It was found that, severe heat transfer deterioration did not occur in the vertically-upward internally-ribbed tube at supercritical pressures, and the variations in the inside wall temperature with the bulk fluid enthalpy experienced three stages, namely, the continuously increasing stage, the smoothly changing stage and another continuously increasing stage at the supercritical pressures; however, at subcritical pressures, there existed at least four stages for the variation of the inside tube wall temperature, i.e., the continuously increasing stage, the basically unchanging stage, the sharply rising stage and another continuously increasing stage. The heat transfer coefficients in the subcritical two-phase region, in which the heat transfer deterioration did not occur, were much greater than those in the heat transfer enhancement region of supercritical pressure water. In the large specific heat region of supercritical pressure water, the enhanced heat transfer was impaired by increasing the heat flux; however, in the subcritical two-phase region, the higher the heat flux, the greater the heat transfer coefficient would be. It was also found that the heat transfer deterioration of supercritical pressure water was similar in mechanism to the DNB (departure from nucleate boiling) at subcritical pressures.  相似文献   

4.
Subcooled flow boiling heat transfer for refrigerant R-134a in vertical cylindrical tubes with 0.83, 1.22 and 1.70 mm internal diameter was experimentally investigated. The effects of the heat flux, q″ = 1–26 kW/m2, mass flux, G = 300–700 kg/m2 s, inlet subcooling, ΔTsub,i = 5–15 °C, system pressure, P = 7.70–10.17 bar, and channel diameter, D, on the subcooled boiling heat transfer were explored in detail. The results are presented in the form of boiling curves and heat transfer coefficients. The boiling curves evidenced the existence of hysteresis when increasing the heat flux until the onset of nucleate boiling, ONB. The wall superheat at ONB was found to be essentially higher than that predicted with correlations for larger tubes. An increase of the mass flux leads, for early subcooled boiling, to an increase in the heat transfer coefficient. However, for fully developed subcooled boiling, increases of the mass flux only result in a slight improvement of the heat transfer. Higher inlet subcooling, higher system pressure and smaller channel diameter lead to better boiling heat transfer. Experimental heat transfer coefficients are compared to predictions from classical correlations available in the literature. None of them predicts the experimental data for all tested conditions.  相似文献   

5.
The influence of oil on nucleate pool boiling heat transfer   总被引:1,自引:0,他引:1  
The influence of various oil contents in R134a is investigated for nucleate pool boiling on copper tubes either sandblasted or with enhanced heating surfaces (GEWA-B tube). Polyolester oils (POE) (Reniso Triton) with medium viscosity 55 cSt (SE55) and high viscosity 170 cSt (SE170) were used. Heat transfer coefficients were obtained for boiling temperatures between −28.6 and +20.1°C. The oil content varied from 0 to 5% mass fraction. For the sandblasted tube and the SE55 oil the heat transfer coefficients for the refrigerant/oil-mixture can be higher or lower than those for the pure refrigerant, depending on oil mass fraction, boiling temperature and heat flux. In some cases the highest heat transfer coefficients were obtained at a mass fraction of 3%. For the 170 cSt oil there is a clear decrease in heat transfer for all variations except for a heat flux 4,000 W/m2 and −10.1°C at 0.5% oil content. The heat transfer coefficients are compared to those in the literature for a smooth stainless steel tube and a platinum wire. For the enhanced tube and 55 cSt oil the heat transfer coefficients are clearly below those for pure refrigerant in all cases. The experimental results for the sandblasted tube are compared with the correlation by Jensen and Jackman. The calculated values are within +20 and −40% for the medium viscosity oil and between +50% and −40% for the high viscosity oil. A correlation for predicting oil-degradation effects on enhanced surfaces does not exist.  相似文献   

6.
An experimental study was carried out to understand the nucleate boiling characteristics and the critical heat flux (CHF) of water, the water based nanofluids and the water based nanoparticle-suspensions in vertical small heated tubes with a closed bottom. Here, the nanofluids consisted of the base liquid, the CuO nanoparticles and the surfactant. The nanoparticle-suspensions consisted of the base liquid and CuO nanoparticles. The surfactant was sodium dodecyl benzene sulfate. The study focused on the influence of the nanoparticles and surfactant on the nucleate boiling characteristics and the CHF. The experimental results indicated that the nanoparticle concentrations of the nanofluids and nanoparticle-suspensions in the tubes do not change during the boiling processes; the nanoparticles in the evaporated liquid are totally carried away by the steam. The boiling heat transfer rates of nanofluids are poorer than that of the base liquid. However, the boiling heat transfer rates of nanoparticle-suspensions are better than that of the base liquid. Comparing with the base liquid, the CHF of the nanofluids and the nanoparticle-suspensions is higher. The CHF is only related to nanoparticle mass concentration when the tube length and the tube diameter are fixed. The experiment confirm that there is a thin nanoparticle coating layer on the heated surface after the nanofluids boiling test but there is no coating layer on the heated surface after the nanoparticle-suspensions boiling test. This coating layer is the main reason that deteriorates the boiling heat transfer rates of nanofluids. An empirical correlation was proposed for predicting the CHF of nanofluids boiling in the vertical tubes with closed bottom.  相似文献   

7.
The paper presents experimental data on pool boiling heat transfer of tandem tubes, arranged one above the other in the same vertical plane. The outer surface of the tubes is provided with the novel microstructures. The structure elements are micropins created by electrolytic deposition of copper upon the tube, using a specially treated polycarbonate foil. By this technique the pins diameter can be varied from 0.1 μm up to 25 μm, the pins height goes up to 100 μm at densities up to 1 × 109 pins/cm2 and pins inclination almost up to 180° regarding the base surface. Micropins with several different inclinations can be created simultaneously on the same surface.Experiments were conducted with two different microstructures using the refrigerant R134a and the highly wetting Fluorinert liquid FC-3284 at pressures of 5-9 bar and 0.5-1.5 bar, respectively. The advantages of the novel microstructure regarding the boiling heat transfer for tandem tubes turned out to be practically the same as for a single tube arrangement. Microstructured tubes have the superheat independent on the heat flux, they show a very low boiling inception superheats (below 2 K), are highly effective in comparison with a technically smooth tubes, and operate stable over the long periods of time.  相似文献   

8.
The heat transfer and bubble formation is investigated in pool boiling of propane. Size distributions of active nucleation sites on single horizontal copper and steel tubes with different diameter and surface finishes have been calculated from heat transfer measurements over wide ranges of heat flux and selected pressure. The model assumptions of Luke and Gorenflo for the heat transfer near growing and departing bubbles, which were applied in the calculations, have been slightly modified and the calculated results have been compared to experimental investigations by high speed video techniques. The calculated number of active sites shows a good coincidence for the tube with smaller diameter, while the results for the tube with larger diameter describe the same relative increase of the active sites. The comparison of the cumulative size distribution of the active and potential nucleation sites demonstrates the same slope of the curve and that the critical radius of a stable bubble nuclei is smaller than the average cavity size.  相似文献   

9.
Comparative numerical study of laminar heat transfer characteristics of annular tubes with sinusoidal wavy fins has been conducted both experimentally and numerically with Re = 299–1,475. The uniform heat flux is imposed on the tube outside wall surface. Two tube materials (copper and stainless steel) are considered. It is found that the fluid temperature profile is not linear but convex along the flow direction due to the axial heat conduction in tube wall, and the effects of axial heat conduction on the heat transfer decreases with an increase in Reynolds number or decrease in tube wall thermal conductivity. The axial distributions of local Nusselt number could reach periodically fully developed after 3–5 cycles. The convectional data reduction method based on the traditional method should be improved for tube with high thermal conductivity or low Reynolds numbers, Otherwise, the heat transfer performance of internally finned tube may be underestimated.  相似文献   

10.
利用格子Boltzmann方法模拟二维水平通道内水的流动沸腾过程,获得不同壁面过热度下流型特点和不同因素对换热过程的影响规律。结果表明,随着壁面过热度升高,流道内流型依次经历从泡状流、弹状流到反环流的转变,平均热流密度和平均换热系数先增大后减小。入口流速降低会使流道内出现受限气泡流,核态沸腾受到抑制。提高入口流速能够有效促进气泡脱离,壁面平均换热系数随入口流速增大而增大,但增长速率有所减小。减小通道宽度有利于汽化现象发生,核态沸腾得到强化,壁面平均换热系数有所提高。  相似文献   

11.
This paper presents the experimental result of a study on the effects of heat transfer enhancement on two-phase flow instabilities in a horizontal in-tube flow boiling system. Five different heat transfer surface configurations and five different inlet temperatures are used to observe the effect of heat transfer enhancement and inlet subcooling. All experiments are carried out at constant heat input, system pressure and exit restriction. Dynamic instabilities, namely pressure-drop type, density-wave type and thermal oscillations are found to occur for all the investigated temperatures and enhancement configurations, and the boundaries for the appearance of these oscillations are found. The effect of the enhancement configurations on the characteristics of the boiling flow dynamic instabilities is studied in detail. The comparison between the bare tube and the enhanced tube configurations are made on the basis of boiling flow instabilities. Differences among the enhanced configurations are also determined to observe which of them is the most stable and unstable one. The amplitudes and periods of pressure-drop type oscillations and density-wave type oscillations for tubes with enhanced surfaces are found to be higher than those of the bare tube. The bare tube is found to be the most stable configuration, while tube with internal springs having bigger pitch is found to be the most unstable one among the tested tubes. It is found that system stability increases with decreasing equivalent diameter for the same type heater tube configurations; however, on the basis of effective diameter there is no single result such as stability increase/decrease with increasing/decreasing effective diameter.  相似文献   

12.
The heat transfer characteristics of supercritical fluids in tubes have been considered indispensable for the design and optimization of the heat exchanger and the energy conversion system. Specifically the cooling heat transfer of supercritical R1234ze(E) in horizontal tubes is a promising heat-power conversion technology; however, there is a scarcity of conducted research in available literature. The present work, the first-ever study in this direction, aims to thoroughly investigate the heat transfer characteristics of supercritical R1234ze(E) which is cooled in horizontal tubes. Experimental work was performed to thoroughly explore and inspect the heat transfer characteristics of supercritical R1234ze(E) passing through the tube of 4.12 mm diameter at 4–5 MPa pressure and 240–400 kg/m2 s mass flux. Furthermore, the simulation study, supporting the experimental investigation under the same conditions of pressure and mass flux, extended the range of tube diameter up to 9.44 mm. The effects of pressure, mass flux and tube diameter on the heat transfer coefficient were carefully analyzed in the present research work. Based on the simulation results and experimental results, heat transfer correlations were newly developed by separating the region above and below the pseudo-critical temperature. The average absolute deviation between the calculated Nusselt numbers by the numerical correlation and the simulation results was found 2.87%; the average absolute deviation between the calculated Nusselt numbers by the experimental correlation and the experimental results was found 5.3%.  相似文献   

13.
The flow boiling heat transfer coefficients of R-134a/R-290/R-600a (91%:4.068%:4.932% by mass) refrigerant mixture are experimentally arrived in two tubes of diameter 9.52 and 12.7 mm. The tests are conducted to target the varied heat flux condition and stratified flow pattern found in evaporators of refrigerators and deep freezers. The varied heat flux condition is imposed on the refrigerant using a coaxial counter-current heat exchanger test section. The experiments are performed for mass flow rates of the refrigerant mixture between 3 and 5 g s−1 and entry temperature between −8.59 and 5.33°C which are bubble temperatures corresponding to a pressure of 3.2 and 5 bar. The influences of heat flux, mass flow rate, pressure, flow pattern, tube diameter on the heat transfer coefficient are discussed. The profound effects of nucleate boiling prevailing even at higher vapor qualities in evaporators are highlighted. The heat transfer coefficient of the refrigerant mixture is also compared with that of R-134a.  相似文献   

14.
对管道内充分发展对流传热过程的有效能损失进行了分析.根据定型流状态下定热流与定壁温换热条件的特点,经代数推演,得到了这两种条件下的表征换热状态、流动功耗以及黏性变化的无量纲形式的有效能损失关系式,适用于不同截面形状的管道内的层流与湍流工况下的有效能分析.  相似文献   

15.
A semi-analytical model is developed for the prediction of flow boiling heat transfer inside vertical porous coated tubes. The model assumes that the forced convection and nucleate boiling coexist together in the annular flow regime. Conservations of mass, momentum, and energy are used to solve for the liquid film thickness and temperature. The heat flux due to nucleate boiling consists of those inside and outside micro-tunnels. To close the equations, a detailed analysis of various forces acting on the bubble is presented to predict its mean departure diameter. The active nucleation site density of porous layer is determined from the pool boiling correlation by introducing suppression factor. The flow boiling heat transfer coefficients of organic fluid (cumene) with high saturation temperature in a vertical flame-spraying porous coated tube are studied numerically. It is shown that the present model can predict most of the experimental values within ±20%. The numerical results also indicate that the nucleate boiling contribution to the overall heat transfer coefficient decreases from 50% to 15% with vapor quality increasing from 0.1 to 0.5.  相似文献   

16.
In this paper, we study the interaction of peristalsis with heat transfer for the flow of a viscous fluid in a vertical porous annular region between two concentric tubes. Long wavelength approximation (that is, the wavelength of the peristaltic wave is large in comparison with the radius of the tube) is used to linearise the governing equations. Using the perturbation method, the solutions are obtained for the velocity and the temperature fields. Also, the closed form expressions are derived for the pressure-flow relationship and the heat transfer at the wall. The effect of pressure drop on flux is observed to be almost negligible for peristaltic waves of large amplitude; however, the mean flux is found to increase by 10-12% as the free convection parameter increases from 1 to 2. Also, the heat transfer at the wall is affected significantly by the amplitude of the peristaltic wave. This warrants further study on the effects of peristalsis on the flow and heat transfer characteristics.  相似文献   

17.
An analytical solution is developed for conjugate heat transfer in a flat-plate heat exchanger with circular embedded channels. The analysis was carried out for fully-developed conditions in the circular tube and uniform heat flux at the plate boundary. The results are applicable to cooling channels that are 50 μm or more in diameter with a large length–diameter ratio. The thermal characteristics of the heat exchanger have been examined for a wide range of the relevant independent parameters and optimum designs for three different sets of constraints have been presented. It was found that the overall thermal resistance increases with the depth of the tube from the heated surface, as well as the spacing between the tubes. For a given combination of tubes’ depth and spacing, there is a certain tube diameter at which the thermal resistance attains a minimum value.  相似文献   

18.
An experiment is carried out to investigate the characteristics of the augmentation of heat transfer and pressure drop by different strip-type inserts in small tube having an inside diameter of 2.0 mm. The effects of the imposed wall heat flux, mass flux, strip inserts with various configurations (heights, widths, pitches) on the measured augmentative heat transfer and pressure drop are examined in detail. In order to obtain insight into the fluid flow phenomena, flow visualization was also made to observe the detailed fluid flow characteristics of the present tubes inserted with strip-type inserts. In addition, comparisons are made with a plain tube having the same length, heat transfer area and experimental conditions. The measured heat transfer coefficients and pressure drops for this small pipe are also emphasized to compare with those for larger pipes. Furthermore, in order to compare results from the different configurations of strip-type inserts, several enhancement factors and performance ratios are defined to account for the effects of augmentation. Moreover, correlation equations for the heat transfer coefficient and pressure drop of the present study are proposed.The financial support extended by the National Science Council of the Republic of China through grant No. NSC-89-2212-E-230-004.  相似文献   

19.
This article reports an experimental investigation on flow boiling heat transfer and pressure drop of refrigerant R-134a in a smooth horizontal and two microfinned tubes from different manufacturers with the same geometric characteristics. Experiments have been carried out in an experimental facility developed for change of phase studies with a test section made with 9.52 mm external diameter, 1.5 m long copper tubes, electrically heated by tape resistors wrapped on the external surface. Tests have been performed under the following conditions: inlet saturation temperature of 5 °C, vapor qualities from 5% to 90%, mass velocity from 100 to 500 kg/s m2, and a heat flux of 5 kW/m2. Experimental results indicated that the heat transfer performance was basically the same for both microfin tubes. The pressure drop is higher in the microfinned tubes in comparison to the smooth tube over the whole range of mass velocities and vapor qualities. The enhancement factor, used to evaluate the combination of heat transfer and pressure drop, is higher than one for both tubes for mass velocities lower than 300 kg/s m2. Values lower than one have been obtained for both tubes in the mass velocity upper range as a result of a significant pressure drop increment not followed by a correspondent increment in the heat transfer coefficient. Some images, illustrating the flow patterns, were obtained from the visualization section, located in the exit of the test section with the same internal diameter of the tested tube.  相似文献   

20.
Convective boiling of HCFC123 and FC72 in 0.19, 0.3 and 0.51 mm ID tubes is investigated. The experimental setup as well as the data reduction procedure has carefully been designed, so that the relative uncertainty interval of the measured heat transfer coefficient in microtubes is kept within ±10%. Up to 70 K liquid superheat over the saturation temperature is observed at low heat and mass fluxes. The onset of the superheat is found to be dependent on the mass flux and the boiling number of the refrigerant examined. In the saturated boiling regime, the heat transfer characteristics are much different from those in conventional-size tubes. The heat transfer coefficient is monotonically decreased with increasing the vapor quality, and becomes independent of the mass flux. Most empirical formulas are not in accordance with the present experimental data. Since the prediction using the nucleate boiling term of Kandlikar’s empirical correlations coincides with the present results, the convection effect should be minor in microtubes. On the other hand, the pressure loss characteristics are qualitatively in accordance with the conventional correlation formula while quantitatively much lower. These phenomena can be explained by the fact that the annular flow prevails in microtubes.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏