首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Pitfalls in compound-specific isotope analysis of environmental samples   总被引:1,自引:0,他引:1  
In the last decade compound-specific stable isotope analysis (CSIA) has evolved as a valuable technique in the field of environmental science, especially in contaminated site assessment. Instrumentation and methods exist for highly precise measurements of the isotopic composition of organic contaminants even in a very low concentration range. Nevertheless, the determination of precise and accurate isotope data of environmental samples can be a challenge. Since CSIA is gaining more and more popularity in the assessment of in situ biodegradation of organic contaminants, an increasing number of authorities and environmental consulting offices are interested in the application of the method for contaminated site remediation. Because of this, it is important to demonstrate the problems and limitations associated with compound-specific isotope measurements of environmental samples. In this review, potential pitfalls of the analytical procedure are critically discussed and strategies to avoid possible sources of error are provided. In order to maintain the analytical quality and to ensure the basis for reliable stable isotope data, recommendations on groundwater sampling, and sample preservation and storage are given. Important aspects of sample preparation and preconcentration techniques to improve sensitivity are highlighted. Problems related to chromatographic resolution and matrix interference are discussed that have to be considered in order to achieve accurate gas chromatography/isotope ratio mass spectrometry measurements. As a result, the need for a thorough investigation of compound-specific isotope fractionation effects introduced by any step of the overall analytical method by standards with known isotopic composition is emphasized. Finally, we address some important points that have to be considered when interpreting data from field investigations. Figure CSIA Principal (Carbon)  相似文献   

2.
Compound-specific stable isotope analysis (CSIA) using gas chromatography-isotope ratio mass spectrometry (GC/IRMS) has developed into a mature analytical method in many application areas over the last decade. This is in particular true for carbon isotope analysis, whereas measurements of the other elements amenable to CSIA (hydrogen, nitrogen, oxygen) are much less routine. In environmental sciences, successful applications to date include (i) the allocation of contaminant sources on a local, regional, and global scale, (ii) the identification and quantification of (bio)transformation reactions on scales ranging from batch experiments to contaminated field sites, and (iii) the characterization of elementary reaction mechanisms that govern product formation. These three application areas are discussed in detail. The investigated spectrum of compounds comprises mainly n-alkanes, monoaromatics such as benzene and toluene, methyl tert-butyl ether (MTBE), polycyclic aromatic hydrocarbons (PAHs), and chlorinated hydrocarbons such as tetrachloromethane, trichloroethylene, and polychlorinated biphenyls (PCBs). Future research directions are primarily set by the state of the art in analytical instrumentation and method development. Approaches to utilize HPLC separation in CSIA, the enhancement of sensitivity of CSIA to allow field investigations in the µg L–1 range, and the development of methods for CSIA of other elements are reviewed. Furthermore, an alternative scheme to evaluate isotope data is outlined that would enable estimates of position-specific kinetic isotope effects and, thus, allow one to extract mechanistic chemical and biochemical information.Abbreviations BTEX benzene, toluene, ethylbenzene, xylenes - MTBE methyl tert-butyl ether - PAHs polycyclic aromatic hydrocarbons - VOCs volatile compounds - PCBs polychlorinated biphenyls - CSIA compound-specific (stable) isotope (ratio) analysis - GC-IRMS, GC/IRMS or GCIRMS gas chromatography-isotope ratio mass spectrometry - GC-C-IRMS, GC/C/IRMS or GCC-IRMS gas chromatography-combustion-isotope ratio mass spectrometry - irmGC/MS isotope ratio monitoring gas chromatograph-mass spectrometry - GC/P/IRMS gas chromatography-pyrolysis-isotope ratio mass spectrometry (used for D/H) - KIE kinetic isotope effect - PSIA position-specific isotope analysis (for intramolecular isotope distribution) - SNIF-NMR site-specific natural isotopic fractionation by nuclear magnetic resonance spectroscopy  相似文献   

3.
Unintended pesticide pollution in soil, crops, and adjacent environments has caused several issues for both pesticide users and consumers. For users, pesticides utilized should provide higher yield and lower persistence while considering both the environment and agricultural products. Most people are concerned that agricultural products expose humans to pesticides accumulating in vegetation. Thus, many countries have guidelines for assessing and managing pesticide pollution, for farming in diverse environments, as all life forms in soil are untargeted to these pesticides. The stable isotope approach has been a useful technique to find the source of organic matter in studies relating to aquatic ecology and environmental sciences since the 1980s. In this study, we discuss commonly used analytical methods using liquid and gas chromatography coupled with isotopic ratio mass spectrometry, as well as the advanced compound-specific isotope analysis (CSIA). CSIA applications are discussed for tracing organic pollutants and understanding chemical reactions (mechanisms) in natural environments. It shows great applicability for the issues on unintended pesticide pollution in several environments with the progress history of isotope application in agricultural and environmental studies. We also suggest future study directions based on the forensic applications of stable isotope analysis to trace pesticides in the environment and crops.  相似文献   

4.
Compound-specific isotope analysis (CSIA) has been established as a useful tool in the field of environmental science, in particular in the assessment of contaminated sites. What limits the use of gas chromatography/isotope ratio mass spectrometry (GC/IRMS) is the low sensitivity of the method compared with GC/MS analysis; however, the development of suitable extraction and enrichment techniques for important groundwater contaminants will extend the fields of application for GC/IRMS. So far, purge and trap (P&T) is the most effective, known preconcentration technique for on-line CSIA with the lowest reported method detection limits (MDLs in the low microg/L range). With the goal of improving the sensitivity of a fully automated GC/IRMS analysis method, a commercially available P&T system was modified. The method was evaluated for ten monoaromatic compounds (benzene, toluene, para-xylene, ethylbenzene, propylbenzene, isopropylbenzene, 1,2,3-trimethylbenzene, 1,2,4-trimethylbenzene, 1,3,5-trimethylbenzene, fluorobenzene) and ten halogenated volatile organic compounds (VOCs) (dichloromethane, cis-1,2-dichloroethene, trans-1,2-dichloroethene, carbon tetrachloride, chloroform, 1,2-dichloroethane, trichloroethene, tetrachlorethene, 1,2-dibromoethane, bromoform). The influence of method parameters, including purge gas flow rates and purge times, on delta13C values of target compounds was evaluated. The P&T method showed good reproducibility, high linearity and small isotopic fractionation. MDLs were determined by consecutive calculation of the delta13C mean values. The last concentration for which the delta13C value was within this iterative interval and for which the standard deviation was lower than +/-0.5 per thousand for triplicate measurements was defined as the MDL. MDLs for monoaromatic compounds between 0.07 and 0.35 microg/L are the lowest values reported so far for continuous-flow isotope ratio measurements using an automated system. MDLs for halogenated hydrocarbons were between 0.76 and 27 microg/L. The environmental applicability of the P&T-GC/IRMS method in the low-microg/L range was demonstrated in a case study on groundwater samples from a former military air field contaminated with VOCs.  相似文献   

5.
Applied gas chromatography coupled to isotope ratio mass spectrometry.   总被引:6,自引:0,他引:6  
Compound-specific isotope analysis (CSIA) by isotope ratio mass spectrometry (IRMS) following on-line combustion (C) of compounds separated by gas chromatography (GC) is a relatively young analytical method. Due to its ability to measure isotope distribution at natural abundance level with great accuracy and high precision, GC-C-IRMS has increasingly become the method of choice in authenticity control of foodstuffs and determination of origin in archaeology, geochemistry, and environmental chemistry. In combination with stable isotope labelled compounds, GC-C-IRMS is also used more and more in biochemical and biomedical application as it offers a reliable and risk-free alternative to the use of radioactive tracers. The literature on these topics is reviewed from the advent of commercial GC-C-IRMS systems in 1990 up to the beginning of 1998. Demands on sample preparation and quality of GC separation for GC-C-IRMS are discussed also.  相似文献   

6.
Carbon isotope analysis by bulk elemental analysis coupled with isotope ratio mass spectrometry has been the mainstay of δ13C analyses both at natural abundance and in tracer studies. More recently, compound‐specific isotope analysis (CSIA) has become established, whereby organic constituents are separated online by gas or liquid chromatography before oxidation and analysis of CO2 for constituent δ13C. Theoretically, there should be concordance between bulk δ13C measurements and carbon‐weighted δ13C measurements of carbon‐containing constituents. To test the concordance between the bulk and CSIA, fish oil was chosen because the majority of carbon in fish oil is in the triacylglycerol form and ~95% of this carbon is amenable to CSIA in the form of fatty acids. Bulk isotope analysis was carried out on aliquots of oil extracted from 55 fish samples and δ13C values were obtained. Free fatty acids (FFAs) were produced from the oil samples by saponification and derivatised to fatty acid methyl esters (FAMEs) for CSIA by gas chromatography/combustion/isotope ratio mass spectrometry. A known amount of an internal standard (C15:0 FAME) was added to allow analyte quantitation. This internal standard was also isotopically calibrated in both its FFA (δ13C = ?34.30‰) and FAME (δ13C = ?34.94‰) form. This allowed reporting of FFA δ13C from measured FAME δ13C values. The bulk δ13C was reconstructed from CSIA data based on each FFA δ13C and the relative amount of CO2 produced by each analyte. The measured bulk mean δ13C (SD) was ?23.75‰ (1.57‰) compared with the reconstructed bulk mean δ13C of ?23.76 (1.44‰) from CSIA and was not significantly different. Further analysis of the data by the Bland‐Altman method did not show particular bias in the data relative to the magnitude of the measurement. Good agreement between the methods was observed with the mean difference between methods (range) of 0.01‰ (?1.50 to 1.30). Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

7.
随着科学技术的飞速发展,质谱检测及其联用技术方法正以前所未有的速度、广度和深度全面渗透到环境分析化学中,其在环境监测中的使用已经或正在日常化.近年来,一些高分辨质谱及其与色谱等的联用技术在目标污染物和非目标污染物的同时甄别鉴定和分析中发挥了重要作用,其对于阐明污染物在环境的归趋具有重要意义.本文对质谱技术及其与气相色谱和液相色谱的联用技术在污染物尤其是新型污染物分析中的进展进行了总结,并对高分辨质谱技术的环境应用研究给于关注,对环境质谱技术的发展方向进行了展望.  相似文献   

8.
9.
Gas chromatography coupled with mass spectrometry (GC–MS) continues to play an important role in the identification and quantification of organic contaminants in environmental samples. GC–MS is one of the most attractive and powerful techniques for routine analysis of some ubiquitous organic pollutants due to its good sensitivity and high selectivity and versatility. This paper presents an overview of recent developments and applications of the GC–MS technique in relation to the analysis in environmental samples of known persistent pollutants and some emerging contaminants. The use of different mass analysers such as linear quadrupole, quadrupole ion-trap, double-focusing sectors and time-of-flight analysers is examined. The advantages and limitations of GC–MS methods for selected applications in the field of environmental analysis are discussed. Recent developments in field-portable GC–MS are also examined.  相似文献   

10.
The analysis of variations in stable isotope composition is becoming an essential approach for evaluating enzymatic and abiotic reactions of organic contaminants in soils and aquatic systems. Different, sometimes complementary analytical techniques are currently used and developed to determine stable isotope ratios in individual organic compounds. Anticipating an increasing demand for compound-specific isotope analysis, this survey compiles information for choosing the most promising analytical approach to an isotope-related problem. To this end, we review the principles of instrumentation for compound-specific isotope analysis and show how they can be exploited to assess contaminant transformation processes. Using chlorinated solvents and triazine herbicides as illustrative examples, we discuss how the isotope-sensitive techniques impact the investigation of stable isotope fractionation in environmental chemistry and microbiology.  相似文献   

11.
Environmental degradation of organic micropollutants is difficult to monitor due to their diffuse and ubiquitous input. Current approaches—concentration measurements over time, or daughter-to-parent compound ratios—may fall short, because they do not consider dilution, compound-specific sorption characteristics or alternative degradation pathways. Compound-specific isotope analysis (CSIA) offers an alternative approach based on evidence from isotope values. Until now, however, the relatively high limits for precise isotope analysis by gas chromatography—isotope ratio mass spectrometry (GC-IRMS) have impeded CSIA of sub-microgram-per-liter scale micropollutant concentrations in field samples. This study presents the first measurements of C and N isotope ratios of the herbicide atrazine and its metabolite desethylatrazine at concentrations of 100 to 1,000 ng/L in natural groundwater samples. Solid-phase extraction and preparative HPLC were tested and validated for preconcentration and cleanup of groundwater samples of up to 10 L without bias by isotope effects. Matrix interferences after solid-phase extraction could be greatly reduced by a preparative HPLC cleanup step prior to GC-IRMS analysis. Sensitivity was increased by a factor of 6 to 8 by changing the injection method from large-volume to cold-on-column injection on the GC-IRMS system. Carbon and nitrogen isotope values of field samples showed no obvious correlation with concentrations or desethylatrazine-to-atrazine ratios. Contrary to expectations, however, δ 13 C values of desethylatrazine were consistently less negative than those of atrazine from the same sites. Potentially, this line of evidence may contain information about further desethylatrazine degradation. In such a case, the common practice of using desethylatrazine-to-atrazine ratios would underestimate natural atrazine degradation.  相似文献   

12.
Summary A new marine sediment Standard Reference Material (SRM) has been prepared and analyzed for the determination of trace organic constituents. SRM 1941, Organics in Marine Sediment, has been certified for concentrations of 11 PAHs using results obtained from gas chromatography (GC) with flame ionization detection, gas chromatography-mass spectrometry, and liquid chromatography with fluorescence detection. Non-certified values for 24 additional PAHs are also reported. GC with electron capture detection was used to provide non-certified concentrations for 15 PCB congeners and 7 chlorinated pesticides. In addition to the organic contaminants, concentrations of 32 major and trace elements were determined using neutron activation analysis, and the sulfur content was also determined using isotope dilution thermal ionization mass spectrometry.  相似文献   

13.
Compound‐specific isotope analysis (CSIA) by liquid chromatography coupled to isotope ratio mass spectrometry (LC/IRMS) has until now been based on ion‐exchange separation. In this work, high‐temperature reversed‐phase liquid chromatography was coupled to, and for the first time carefully evaluated for, isotope ratio mass spectrometry (HT‐LC/IRMS) with four different stationary phases. Under isothermal and temperature gradient conditions, the column bleed of XBridge C18 (up to 180 °C), Acquity C18 (up to 200 °C), Triart C18 (up to 150 °C), and Zirchrom PBD (up to 150 °C) had no influence on the precision and accuracy of δ13C measurements, demonstrating the suitability of these columns for HT‐LC/IRMS analysis. Increasing the temperature during the LC/IRMS analysis of caffeine on two C18 columns was observed to result in shortened analysis time. The detection limit of HT‐RPLC/IRMS obtained for caffeine was 30 mg L–1 (corresponding to 12.4 nmol carbon on‐column). Temperature‐programmed LC/IRMS (i) accomplished complete separation of a mixture of caffeine derivatives and a mixture of phenols and (ii) did not affect the precision and accuracy of δ13C measurements compared with flow injection analysis without a column. With temperature‐programmed LC/IRMS, some compounds that coelute at room temperature could be baseline resolved and analyzed for their individual δ13C values, leading to an important extension of the application range of CSIA. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

14.
The use of isotope ratio infrared spectroscopy (IRIS) for the stable hydrogen and oxygen isotope analysis of water is increasing. While IRIS has many advantages over traditional isotope ratio mass spectrometry (IRMS), it may also be prone to errors that do not impact upon IRMS analyses. Of particular concern is the potential for contaminants in the water sample to interfere with the spectroscopy, thus leading to erroneous stable isotope data. Water extracted from plant and soil samples may often contain organic contaminants. The extent to which contaminants may interfere with IRIS and thus impact upon data quality is presently unknown. We tested the performance of IRIS relative to IRMS for water extracted from 11 plant species and one organic soil horizon. IRIS deviated considerably from IRMS for over half of the samples tested, with deviations as large as 46‰ (δ2H) and 15.4‰ (δ18O) being measured. This effect was reduced somewhat by using activated charcoal to remove organics from the water; however, deviations as large as 35‰ (δ2H) and 11.8‰ (δ18O) were still measured for these cleaned samples. Interestingly, the use of activated charcoal to clean water samples had less effect than previously thought for IRMS analyses. Our data show that extreme caution is required when using IRIS to analyse water samples that may contain organic contaminants. We suggest that the development of new cleaning techniques for removing organic contaminants together with instrument‐based software to flag potentially problematic samples are necessary to ensure accurate plant and soil water analyses using IRIS. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

15.
An overview of liquid chromatography–mass spectrometry methods used for the determination of trace organic contaminants in environmental samples is presented. Among the organic contaminants the focus is given on five groups of emerging contaminants that raised most concern as environmental contaminants and therefore attracted attention of a research community: pharmaceuticals, drugs of abuse, polar pesticides, perfluorinated compounds and nanoparticles. Various aspects of current LC–MS methodology, using tandem and hybrid MS instruments, including sample preparation, are discussed.  相似文献   

16.
Compound‐specific isotopic analysis (CSIA) can provide information about the origin of analysed compounds; for instance, polycyclic aromatic hydrocarbons (PAHs) in aerosols. This could be a valuable tool in source apportionment of particulate matter (PM) air pollution. Because gas chromatography–combustion–isotope ratio mass spectrometry (GC‐C‐IRMS) analysis requires an amount of at least 10 ng of an individual PAH, a high concentration of PAHs in the injected extract is needed. When the concentration is low a large volume injector creates the possibility of introducing a satisfactory amount of individual PAHs. In this study a temperature‐programmable injector was coupled to GC‐C‐IRMS and injection parameters (solvent level, transfer column flow, transfers time) were optimised using six solid aromatic compounds (anthracene, fluoranthene, pyrene, benzo[b]fluoranthene, benzo[k]fluoranthene, benzo[a]pyrene) dissolved in n‐pentane and EPA 610 reference mixture. CSIA results for solid PAHs were compared with results obtained for the single components analysed by elemental analysis–isotope ratio mass spectrometry. The injection method was validated for two sample injection volumes, 50 and 100 µL. This method was also compared with commonly used splitless injection. To be included in the study, measurements had to have an uncertainty lower than 0.5‰ for and a minimum peak height of 200 mV. The lower concentration limits at which these criteria were fulfilled for PAHs were 30 mg/L for 1 µL in splitless injection and 0.3 and 0.2 mg/L for 50 and 100 µL, respectively, in large volume injection. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

17.
An analysis method for aqueous samples by the direct combination of C18/SCX mixed mode thin-film microextraction (TFME) and desorption electrospray ionization mass spectrometry (DESI-MS) was developed. Both techniques make analytical workflow simpler and faster, hence the combination of the two techniques enables considerably shorter analysis time compared to the traditional liquid chromatography mass spectrometry (LC-MS) approach. The method was characterized using carbamazepine and triclosan as typical examples for pharmaceuticals and personal care product (PPCP) components which draw increasing attention as wastewater-derived environmental contaminants. Both model compounds were successfully detected in real wastewater samples and their concentrations determined using external calibration with isotope labeled standards. Effects of temperature, agitation, sample volume, and exposure time were investigated in the case of spiked aqueous samples. Results were compared to those of parallel HPLC-MS determinations and good agreement was found through a three orders of magnitude wide concentration range. Serious matrix effects were observed in treated wastewater, but lower limits of detection were still found to be in the low ng L(-1) range. Using an Orbitrap mass spectrometer, the technique was found to be ideal for screening purposes and led to the detection of various different PPCP components in wastewater treatment plant effluents, including beta-blockers, nonsteroidal anti-inflammatory drugs, and UV filters.  相似文献   

18.
One of the factors that may explain nowadays honeybees' colonies losses is the increasing presence of chemicals in the environment. The aim of this study is to obtain a global view of the presence of environmental contaminants in beehives and, develop a fast, cheap and sensitive tool to analyze environmental contaminants in apiarian matrices. A multi residue analysis was developed to quantify 80 environmental contaminants, pesticides and veterinary drugs, belonging to different chemical classes, in honeys, honeybees and pollens. It consists in a single extraction, based on a modified "QuEChERS method", followed by gas chromatography coupled with Time of Flight mass spectrometry (GC-ToF) and liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS). The "QuEChERS method" combines salting-out liquid-liquid extraction with acetonitrile and a dispersive-SPE clean up. It was adjusted to honey and especially to honeybee and pollen, by adding a small fraction of hexane in acetonitrile to eliminate lipids that interfere with mass spectrometry analysis. This method, combined with accurate and sensitive detection, allowed quantification and confirmation at levels as low as 10 ng/g, with recoveries between 60 and 120%. Application to more than 100 samples of each matrix was achieved for a global view of pesticide presence in the honeybee environment. Relatively high percentages of honeys, honeybees and pollens were found to be contaminated by pesticides used to combat varroa but also by fungicides like carbendazim and ubiquitous contaminants.  相似文献   

19.
Halogenated organic contaminants, including legislated and potential persistent organic pollutants and their precursors, represent a major environmental concern due to their hazardous effects in humans and wildlife as well as their ability to bioaccumulate through the food chain, their high resistance to environmental degradation, and their long-range atmospheric transport potential. The monitoring of these compounds in the environment at ultra-trace concentration levels requires highly selective and sensitive analytical methodologies. The lack of reference step-by-step methods led to a high number of reliable determinations depending on analytes, the complexity of the sample, and available instrumentation. Thus, this review article is mainly focused on the last advances in the analytical methodologies for the determination of halogenated organic contaminants. Methodologies regarding sample treatment, chromatographic separation, and mass spectrometry analysis have been reviewed to finally highlight the future perspectives for the improvement of the analytical determinations of these compounds and the throughput of environmental control laboratories in this field.  相似文献   

20.
In this study, we evaluate advantages and disadvantages of three hyphenated techniques for mercury speciation analysis in different sample matrices using gas chromatography (GC) with mass spectrometry (GC-MS), inductively coupled plasma mass spectrometry (GC-ICP-MS) and pyrolysis atomic fluorescence (GC-pyro-AFS) detection. Aqueous ethylation with NaBEt(4) was required in all cases. All systems were validated with respect to precision, with repeatability and reproducibility <5% RSD, confirmed by the Snedecor F-test. All methods proved to be robust according to a Plackett-Burnham design for 7 factors and 15 experiments, and calculations were carried out using the procedures described by Youden and Steiner. In order to evaluate accuracy, certified reference materials (DORM-2 and DOLT-3) were analyzed after closed-vessel microwave extraction with tetramethylammonium hydroxide (TMAH). No statistically significant differences were found to the certified values (p=0.05). The suitability for water samples analysis with different organic matter and chloride contents was evaluated by recovery experiments in synthetic spiked waters. Absolute detection and quantification limits were in the range of 2-6 pg for GC-pyro-AFS, 1-4 pg for GC-MS, with 0.05-0.21 pg for GC-ICP-MS showing the best limits of detection for the three systems employed. However, all systems are sufficiently sensitive for mercury speciation in environmental samples, with GC-MS and GC-ICP-MS offering isotope analysis capabilities for the use of species-specific isotope dilution analysis, and GC-pyro-AFS being the most cost effective alternative.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号