首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 105 毫秒
1.
Summary The determination of transuranic (TRU) content in nuclear wastes, reactor materials, process solutions, and various other matrices is required in support of material assessment, environmental restoration, and waste processing activities. We have found that direct measurement of TRU is possible using surface passivated ion implanted planar silicon diode detectors. The performance and durability of modern silicon diodes enables direct detection of alpha-particles, with retention of some spectral information, through small air gaps or under direct contact with liquid or solid samples. We will present results on the performance of silicon diode detectors for the determination of TRU in liquids.  相似文献   

2.
Although much progress was made by using high purity gemanium detectors for direct measurement of239Pu in man, the improvement of lung spectroscopy sensitivity remains a challenge. Previous work showed that passivated implanted planar silicon detectors could provide an alternative by combining high-energy resolution at room temperature and planar geometry with large detection arrays. This paper reports on the status of this research based on the characterisation of 3×3 cm2 and 6×3 cm2 strip silicon detectors. Furthemore, the possibility to apply such detectors towards other monitoring problems for accidental situations such as the direct measurement of small contaminated surfaces was investigated.  相似文献   

3.
Triply coupled high performance liquid chromatography using diode array detection and positive ion electrospray mass spectrometry of 2- and 3-hydroxypyridine is presented. Considerations of the physical method for coupling the two detectors, the influence of pH on retention times, the cone voltage of the mass spectrometer and the linear concentration ranges are described. Data from both detectors are aligned and interpolated. The analyte mass spectra are reduced to 20 significant masses. Principal components plots on the raw, normalised and standardised data, derivatives to determine composition 1 regions, deconvolution and procrustes analysis to compare data from both detectors are discussed. Common trends in both mass spectral and diode array chromatograms are interpreted. This paper represents a new approach to common processing of chromatographic data from two detectors.  相似文献   

4.
PC-controlled non-destructive method and the appropriate equipment for the determination of one- or two- dimensional distribution of more than one beta tracer in a single measurement are described as well as the silicon detectors developed for these measurements. The use of the method is illustrated by examples from life sciences and environmental protection.  相似文献   

5.
Fultz ML  Durst RA 《Talanta》1983,30(12):933-939
Two multichannel image detectors, a vidicon and a silicon photodiode array, were investigated for their performance as detectors in ultraviolet-visible absorption spectroelectrochemical experiments. Their spectral band-pass, dispersion, dynamic range, and precision of absorbance measurements were compared. o-Tolidine was used as a model compound to study their performance in a spectro-potentiostatic experiment using an optically transparent thin-layer electrode. Both detectors performed well, but the silicon photodiode array had twice the spectral resolution and dynamic absorbance range of the vidicon detector.  相似文献   

6.
The paper describes a research of possible application of UTEVA and TRU resins and anion exchanger AMBERLITE CG-400 in nitrate form for the isolation of uranium and thorium from natural samples. The results of determination of distribution coefficient have shown that uranium and thorium bind on TRU and UTEVA resins from the solutions of nitric and hydrochloric acids, and binding strength increases proportionally to increase the concentration of acids. Uranium and thorium bind rather strongly to TRU resin from the nitric acid in concentration ranging from 0.5 to 5 mol L−1, while large quantities of other ions present in the sample do not influence on the binding strength. Due to the difference in binding strength in HCl and HNO3 respectively, uranium and thorium can be easily separated from each other on the columns filled with TRU resin. Furthermore, thorium binds to anion exchanger in nitrate form from alcohol solutions of nitric acid very strongly, while uranium does not, so they can be easily separated. Based on these results, we have created the procedures of preconcentration and separation of uranium and thorium from the soil, drinking water and seawater samples by using TRU and UTEVA resins and strong base anion exchangers in nitrate form. In one of the procedures, uranium and thorium bind directly from the samples of drinking water and seawater on the column filled with TRU resin from 0.5 mol L−1 HNO3 in a water sample. After binding, thorium is separated from uranium with 0.5 mol L−1 HCl, and uranium is eluted with deionised water. By applying the described procedure, it is possible to achieve the concentration factor of over 1000 for the column filled with 1 g of resin and splashed with 2 L of the sample. Spectrophotometric determination with Arsenazo III, with this concentration factor results in detection limits below 1 μg L−1 for uranium and thorium. In the second procedure, uranium and thorium are isolated from the soil samples with TRU resin, while they are separated from each other on the column filled with anion exchanger in alcohol solutions. Anion exchanger combined with alcohol solutions enables isolation of thorium from soil samples and its separation from a wide range of elements, as well as spectrophotometric determination, ICP-MS determination, and other determination techniques.  相似文献   

7.
Summary Iron separation is described from liquid samples with a high concentration of ions that enables simple determination of 55Fe. One of the described methods consists of iron precipitation from a large volume seawater by sodium hydroxide and/or ammonium carbonate and separation from other elements (Ca, Sr, Cu, Mg, etc.) on a TRU column with 4M HCl or 8M HNO3. In the other procedure iron is separated directly from a mixture of seawater samples and HCl on a TRU column. In both methods, the iron recovery is almost 100%. After separation, 55Fe is determined by counting with a liquid scintillation counter. The binding of Fe and Zn on TEVA, U/TEVA and TRU resins from seawater solutions of HCl and HNO3depends on the type of the resin, concentration of acid and other ions. Iron and zinc can be separated from seawater on a U/TEVA column with 2M HCl.  相似文献   

8.
A simple, direct microanalytical method for quantitative determination of silicon in human whole blood, serum, urine, and milk by furnace atomic absorption technique has been developed. The method employs standard additions and combines the inherent specificity and simplicity of atomic absorption analysis with the greatly increased sensitivity possible with a heated graphite tube atomizer for the determination of silicon in microliter samples. The sensitivity of the method is 1.3 ng. The method is suitable for the direct analysis of silicon with no sample preparation other than dilution with deionized water, thereby minimizing contamination due to sample preparation. The relative standard deviation for 10 μl of blood (1:1), serum (1:1), urine (1:7), and milk (1:1) was 3.45% or less.  相似文献   

9.
A new analytical strategy was established to improve the determination and identification performance during analyses of microcystins and diarrhetic shellfish poisoning (DSP) toxins in different matrices. Automated high performance size exclusion chromatography (gel permeation chromatography, SEC) was applied for the clean-up of raw extracts from algae and mussel tissue containing either microcystins or DSP toxins. The cleaned raw extracts are well suited for the direct determination of microcystins and DSP toxins by HPLC/MS. The analyses of cleaned raw extracts containing microcystin by HPLC and UV/diode array detection (DAD) revealed chromatograms without interfering peaks. Additionally, methods for the identification of unknown microcystins and those not available as standards were developed and established. The proposed strategy is exemplarily demonstrated for the analyses of a natural algae community from a lake in Slowakia and a naturally contaminated mussel from Portugal.  相似文献   

10.
潘城  吴凌  谢勇  许文琪  白洋  黄永辉  胡朝阳 《色谱》2018,36(9):904-910
建立了高效液相色谱分离检测化妆品中12种直接染料的方法。采用XB-C18色谱柱分离,以乙腈-0.02 mol/L乙酸铵水溶液(pH 9.0)为流动相梯度洗脱,二极管阵列检测器检测。结果表明,12种直接染料在线性范围内具有良好的线性关系,相关系数均> 0.999;方法的检出限为0.017~1.7 μ g/g,回收率为85.6%~113.4%,相对标准偏差为1.0%~7.7%;日内和日间精密度分别为0.4%~6.5%和0.2%~7.5%。该法简单快速,灵敏度高,定量准确可靠,适用于化妆品中直接染料的日常检测。  相似文献   

11.
A fast, sensitive and reliable method for the indirect atomic absorption determination of SiO2 in copper composite coatings after extraction of silicomolybdic acid in a mixture of isobutyl methyl ketone and butanol (volume ratio 5?:?1) and measurement of the molybdenum absorbance in an air/acetylene flame is described. The experimental conditions are optimized for (i) prevention of the silicon polymerization during sample preparation and storage; (ii) for overcoming of the Cu(SiF6) – complex formation and (iii) for quantitative extraction of the yellow complex into the organic phase for a wide silicon concentration range. The method permits the determination of 0.5–10 mg/g Si in copper. The analytical performance of the proposed method is compared with direct Si determination using ICP-AES.  相似文献   

12.
This paper describes an extraction method using a polypropylene membrane supporting dihexyl ether (three-phase hollow fiber-based liquid phase microextraction (HF-LPME)) for the analysis of several pharmaceuticals (salicylic acid (SAC), ibuprofen (IBU) and diclofenac (DIC)) followed by a HPLC determination using a monolithic silica type HPLC column, that allows lower retention times than the usual packed columns with adequate resolution. Detection was realized by means of a coupled in series diode array (DAD) and fluorescence (FLD) detectors. HF-LPME is a relatively new technique employed in analytical chemistry for sample pretreatment which offers more selectivity and sensitivity than any traditional extraction technique. Detection limits by DAD are 12, 53 and 40 ng mL−1 for salicylic acid, diclofenac and ibuprofen, respectively and by FLD 7 and 2 ng mL−1 for salicylic acid, and ibuprofen. The method has been successfully applied to their direct determination in human urine and the results obtained demonstrated that could be also applied to the determination of the corresponding metabolites.  相似文献   

13.
A new rapid method for the determination of actinides in asphalt samples has been developed that can be used in emergency response situations or for routine analysis. If a radiological dispersive device, improvised nuclear device or a nuclear accident such as the accident at the Fukushima Nuclear Power Plant in March, 2011 occurs, there will be an urgent need for rapid analyses of many different environmental matrices, including asphalt materials, to support dose mitigation and environmental clean-up. The new method for the determination of actinides in asphalt utilizes a rapid furnace step to destroy bitumen and organics present in the asphalt and sodium hydroxide fusion to digest the remaining sample. Sample preconcentration steps are used to collect the actinides and a new stacked TRU Resin + DGA Resin column method is employed to separate the actinide isotopes in the asphalt samples. The TRU Resin plus DGA Resin separation approach, which allows sequential separation of plutonium, uranium, americium and curium isotopes in asphalt samples, can be applied to soil samples as well.  相似文献   

14.
Tadalafil is used for the treatment of erectile dysfunction. Its related patents expired in 2016, and so related generic drug production is predicted to be increased. This work is focused on developing a fast ultra‐high‐performance liquid chromatography with diode array detection and/or mass spectrometry detection for the separation and determination of tadalafil and its impurities in pharmaceutical samples. A modern reversed‐phase stationary phase with sub‐2 μm particle size, Zorbax StableBond Rapid Resolution High Definition with octylsilane chemically bonded phase to totally porous silica particles, was used for the solving this problem. Column temperature was set at 40 ± 0.1°C. A mobile phase consisting of acetonitrile and aqueous solution of 0.1% (v /v) trifluoroacetic acid for diode array detection detection and 0.05% (v /v) formic acid, both running at a flow rate of 0.62 mL/min, were used to achieve the required separation of all components within a 5 min run. The limit of detection was 3.5 μg/L and the limit of quantification was 10.0 μg/L for the method for both UV and MS detectors. Accurate mass spectra of tadalafil's related impurities are shown for advanced confirmation. The method is directly transferable to routine analysis of tadalafil in pharmaceutical and control laboratories.  相似文献   

15.
Battelle, Pacific Northwest Laboratories has recently developed, tested and field-demonstrated a technology for the direct assay of transuranic radionuclides (TRU), fission products, and activation products in a variety of radwaste packages generated at commercial nuclear power plants. This technology involves non-destructive passive neutron counting for determination of nanocurie/gram quantities of the TRU radionuclides. Direct gamma spectrometry combined with thermoluminescent dosimetry (TLD) and correlation analysis is also utilized to determine the concentrations of the fission and activation products present in the radwaste packages. Employing counting times of 10 to 20 minutes, a complete analysis of all radionuclides specified for assay by the U.S. Nuclear Regulatory Commission (in 10CFR61) prior to shallow-land disposal of commercial radwastes can be measured at concentrations at least tenfold below the least restrictive Class A waste catagory.  相似文献   

16.
A new analytical strategy was established to improve the determination and identification performance during analyses of microcystins and diarrhetic shellfish poisoning (DSP) toxins in different matrices. Automated high performance size exclusion chromatography (gel permeation chromatography, SEC) was applied for the clean-up of raw extracts from algae and mussel tissue containing either microcystins or DSP toxins. The cleaned raw extracts are well suited for the direct determination of microcystins and DSP toxins by HPLC/MS. The analyses of cleaned raw extracts containing microcystin by HPLC and UV/diode array detection (DAD) revealed chromatograms without interfering peaks. Additionally, methods for the identification of unknown microcystins and those not available as standards were developed and established. The proposed strategy is exemplarily demonstrated for the analyses of a natural algae community from a lake in Slowakia and a naturally contaminated mussel from Portugal. Received: 23 July 1999 / Revised: 9 September 1999 / Accepted: 16 September 1999  相似文献   

17.
The publications dedicated to the determination of individual sulfur-containing compounds in liquid hydrocarbon raw materials and their processing products by gas chromatography are summarized. In the analysis of petroleum raw materials, the preliminary separation of sulfur-containing compounds and a hydrocarbon matrix is usually performed. In the analysis of liquid oil refining products and gas condensate, the direct determination of individual sulfur-containing compounds can be frequently conducted. The use of currently available sulfur-selective chemiluminescence and atomic emission detectors in combination with nonpolar or slightly polar capillary columns and also two-dimensional chromatography is the most promising.  相似文献   

18.
X-射线荧光光谱法直接测定电工硅钢钢屑中的微量元素   总被引:2,自引:1,他引:1  
报道了X射线荧光光谱法直接测定电工硅钢钢屑样品微量元素的新方法,校正了样品中元素中间的基体效应影响和校正了钢屑样品的不同颗粒结构,不同几何形态及不同表面状态的影响,使钢屑样品可不经处理直接测定,操作简便。  相似文献   

19.
The sustained high release of catecholamines to circulation is a deleterious condition that may induce toxicity, which seems to be partially related to the products formed by oxidation of catecholamines that can be further conjugated with glutathione (GSH). The aim of the present study was to develop a method for the determination of GSH adducts of adrenaline in biological samples. Two position isomers of the glutathion-S-yl-adrenaline were synthesized and characterized by HPLC using diode array, coulometric and mass detectors. A method for the extraction of these adducts from human plasma was also developed, based on adsorption to activated alumina, which showed adequate recoveries and proved to be crucial in removing interferences from plasma. The selectivity, precision and linearity of the method were all within the accepted values for these parameters. Furthermore, the sensitivity of this method allows the detection of adduct amounts that are within the range of the expected concentrations for these adducts under certain pathophysiological conditions and/or drug treatments. In conclusion, the development of this method allows the direct analysis of GSH adducts of adrenaline in human plasma, providing a valuable tool for the study of the catecholamine oxidation process and its related toxicity.  相似文献   

20.
We constructed a simple fluorescence detector for both direct and indirect CE methods using a blue light-emitted diode (470 nm) as excitation source, a bifurcated optical fiber as a waveguide, and a CCD camera as a detector. The connection of all the components is fairly easy even for nonexperts and the use of a CCD camera improves the applicability of this detector compared to the others using PMTs because it permits the recording of 2-D electropherograms or phosphorescence measurements. This detector provides a compact, low cost, and rapid system for the determination of native fluorescence compounds which have high quantum yields by CE with direct fluorescence detection, showing an LOD of 2.6 x 10(-6) M for fluorescein; the determination of fluorescence derivative compounds by CE with direct fluorescence detection, showing an LOD of 1.6 x 10(-7) M for FITC-labeled 1,6-diaminohexane; and nonfluorescence compounds by CE with indirect fluorescence detection with an LOD of 2.7 x 10(-6) M for gallic acid.  相似文献   