首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 859 毫秒
1.
Tris(2,4,6-trimethoxyphenyl)phosphonium propylamine bromide (TMPP) has been used for the derivatisation of maleic, fumaric, sorbic and salicylic acids to facilitate determination using liquid chromatography/electrospray ionisation tandem mass spectrometry (LC/ESI-MS/MS) in positive ion mode. Detection limits, achieved using multiple reaction monitoring mode, were 2, 4, 0.4 and 540 fmol (5 muL injection) for derivatised fumaric, sorbic, maleic and salicylic acids, respectively. In comparison, detection limits achieved in negative ion mode for the underivatised acids were 24, 51, 2, and 117 fmol, respectively. The method was successfully used for the determination of sorbic acid in a sample of Panadol. The derivatisation of salicylic acid was not as successful, probably due to poor reaction efficiency.  相似文献   

2.
The identification, quantification and localisation of steroids in biological fluids and tissues are subjects of considerable importance. Not only do steroids have classical hormonal properties via binding to nuclear receptors, they can also elicit cellular responses via interactions with other proteins. For mass spectrometric analysis, neutral steroids are not readily ionised by either electrospray (ES) or matrix-assisted laser desorption/ionisation (MALDI). In this communication a derivatisation protocol is presented which allows for the rapid analysis of neutral oxosteroids by both ES and MALDI mass spectrometry. Neutral oxosteroids are derivatised to Girard P hydrazones. When analysed by tandem mass spectrometry the derivatised steroids fragment to give structurally informative spectra allowing subsequent steroid identification. The derivatisation method is simple, the reagents are commercially available, and reaction products are easily isolated from the reaction mixture. Analyte identification can be performed at the sub-pg level.  相似文献   

3.
Succinimidylferrocenyl propionate (SFP) is introduced as labelling agent for amino functions in peptides and proteins. The resulting derivatives are characterised by considerably lower polarity compared with the native analytes and can thus be well separated by means of reversed phase liquid chromatography (RP-LC). The reaction products are characterised by electrospray ionisation mass spectrometry (ESI-MS) and inductively coupled plasma mass spectrometry (ICP-MS). A further advantage of the method is a simple and straightforward derivatisation protocol. Different basic and acidic model proteins as lysozyme, ß-lactoglobulin A and insulin were derivatised using SFP. Furthermore, the first dual-labelling strategy of thiol and amino groups with ferrocene-based reagents is presented. Whereas the amino groups were derivatised with SFP, the thiol groups were functionalised by reaction with ferrocenecarboxylic acid(2-maleimidoyl)ethylamide. Again, LC/ESI-MS is a suitable tool to characterise the modified peptides and proteins.  相似文献   

4.
A sensitive and simple method based on ultrasonication extraction with a hexane/acetone (2:1, v/v) mixture, followed by clean up of the extract by solid-phase extraction (SPE) and gas chromatography/mass spectrometry (GC/MS) detection, has been developed and validated for the analysis of 20 estrogenic endocrine-disrupting chemicals (EEDCs) including phenolic xenoestrogens, synthetic and natural estrogens in river sediment. After extraction and purification, analytes are derivatised with a BSTFA/TMCS/pyridine (49:1:50, v/v/v) mixture and quantified by GC/MS. The GC/MS method involves switching between electron ionisation (EI) and chemical ionisation (CI); it also switches between selected ion storage and tandem mass spectrometry detection. The applicability of the method has been demonstrated by analysing extracts of French river sediments for which bioanalytical tests (in vitro) had already shown that they were impacted by estrogenic endocrine disrupters. The biological contribution of all the products detected in each sediment extract was compared to the estrogenic activity measured by bioassays.  相似文献   

5.
A simple, highly selective and sensitive method for the determination of 14 representative alkylphenols from phenol (C0) to nonylphenol (C9) in produced water is described. Solid-phase extraction (SPE) by anion-exchange sorbent is used to extract alkylphenols from produced water. The samples are then derivatised by pentafluorobenzoyl chloride and analysed on GC-MS (negative ion chemical ionisation, NCI). The derivatisation procedure has been validated by means of two-level factorial design (2(7-4)) experiments. Quantification is done with isotope dilution of five internal standards of different alkyl chain length. The detection limits were at low ng/l levels. A comparison with GC-MS analysis of non-derivatised alkylphenol samples revealed the advantage of derivatisation as described in the method.  相似文献   

6.
A single step derivatisation for the determination of putrescine and cadaverine by gas chromatography using trifluoroacetylacetone (TFAA) in methanol or ethanol was studied and optimised. The derivatives were analysed by an iontrap gas chromatograph-mass spectrometer (GC-MS) operating with electron impact ionisation with selective ion storage (EI-SIS) mode. The optimised mole ratios for TFAA/putrescine and TFAA/cadaverine reactions were 5/1 and 5.8/1 respectively with a reaction time of 15 minutes at 95oC. The retention times for the derivatised putrescine and cadaverine were 11.3 and 12.2 minutes respectively using the capillary column, CP-Sil 8CB; 30 m length x 0.25 mm i.d. x 0.25 mm film. The correlation coefficients (R2) of calibration curves for putrescine and cadaverine were 0.991 and 0.990 respectively over a concentration range of 100 ng cm−3 to 1500 ng cm−3. The method developed was found to be simple (single-stage derivatisation), rapid (15 minutes derivatisation & 14 minutes GC/MS run) and accurate (putrescine and cadaverine recoveries 94.8%–97.7%).   相似文献   

7.
The analysis of chemical warfare agents and their degradation products is an important component of verification of compliance with the Chemical Weapons Convention. Gas and liquid chromatography, particularly combined with mass spectrometry, are the major techniques used to detect and identify chemicals of concern to the Convention. The more polar analytes, and some of the more reactive or highly volatile agents, are usually derivatised to facilitate chromatography, and to impart properties beneficial for detection. This review focuses on derivatisation reactions used in the chromatographic analysis of chemical warfare agents, their degradation products and metabolites.  相似文献   

8.
The diagnosis of inherited disorders of amino acids (AA) metabolism is usually performed on automated analysers by ion-exchange chromatography and quantification after ninhydrin derivatisation of about 50 different AA. A single run liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for these molecules can be an alternative to this time-consuming technique. The first step of this development is the infusion study of the fragmentation of 79 molecules of biological interest in electrospray ionisation tandem mass spectrometry (ESI-MS/MS), in positive and in negative ionisation mode. Among them, three molecules can be detected only in negative ionisation mode, 38 only in positive mode and 38 in the two modes. All the most abundant fragmentations are presented, with optimisation of the MS/MS parameters. The positive ionisation mode was retained for the simultaneous analysis of 76 molecules. One sensitive and/or specific transition is proposed for the monitoring of each molecule. Improvement in sensitivity of detection was obtained with the use of an acidic mobile phase. Flow injection analysis studies led us to highlight a number of interferences-due to isobaric molecules, to in-source collision-induced dissociation, or to natural isotopic distribution of the elements-which are listed. For a reliable quantification method, these molecules have to be separated by LC before analysis in the tandem mass spectrometer. Ion-pairing reversed-phase liquid chromatography (RPLC) using perfluorinated carboxylic acids as ion-pairing agents has already been found suitable for analysis of AA in MS/MS positive ionisation mode and is under development.  相似文献   

9.
Chen L  Choo J 《Electrophoresis》2008,29(9):1815-1828
Microfluidic chip devices and their application to sensitive chemical and biological analyses have attracted significant attention over the past decade. The miniaturization of reaction systems offers practical advantages over conventional benchtop systems. In this case, however, a highly sensitive on-chip detection method is important for the monitoring of chemical reactions as well as for the detection of analytes inside the channel because the detection volume in a micrometer-size channel is extremely small. Recently, a surface-enhanced Raman scattering (SERS) technique is being regarded as a potential candidate for the highly sensitive detection of analytes in a microfluidic chip. This review provides a general survey and an in-depth look at recent developments in SERS techniques for the biological/environmental analysis of minute analytes in a microfluidic chip.  相似文献   

10.
A compound library consisting of 144 pyrazole carboxylic acids and six sublibraries consisting of 24 components was analysed using electrospray ionisation Fourier transform ion cyclotron resonance mass spectrometry (ESI-FTICR-MS). The library was synthesised by the split-mix method and investigated by direct infusion analysis by which 134 compounds were detected. FTICR-MS is predestined for the direct characterisation of complex compound libraries because of its outstanding mass resolution and mass accuracy. However, discrimination within the electrospray ionisation process sometimes leads to signal suppression and thus to misinterpretation of the synthetic results. Using micro-HPLC/MS we were able to assign all 144 compounds including all pairs of isobaric pyrazoles. We also show that, due to partial separation, FTICR-MS is indispensable for proper detection of co-eluting compounds.  相似文献   

11.
The application of voltage in micro-high performance liquid chromatography (micro-HPLC) creates a system where separation is governed by a hybrid differential migration process, which entails the features of both HPLC and capillary zone electrophoresis (CZE), i.e., chromatographic retention and electrophoretic migration. In this paper, we use our previously published approach to decouple these two mechanisms via analysis of the input data for estimation of electrokinetic parameters, such as conductivity, equivalent lengths, mobilities and velocities. Separation of weakly retained, charged analytes was performed via voltage-assisted micro-HPLC. Contrary to conclusions from data analysis using the conventional definitions of the retention factor, it is shown that our approach allows us to isolate the "chromatographic retention" component and thus, investigate the "modification" of the retention process upon application of voltage in micro-HPLC. It is shown that the traditional approaches of calculating retention factor would erroneously lead to conclusion that the retention behavior of these analytes changes upon application of voltage. However, the approach suggested here demonstrates that under the conditions investigated, most of the charged analytes do not show any significant retention on the columns and that all the changes in their retention times can be attributed to their electrophoretic migration.  相似文献   

12.
A simple method has been developed for the pre-column derivatisation of low molecular weight primary and secondary amines and carboxylic acids using quaternary nitrogen compounds to enhance their detection by liquid chromatography/electrospray ionisation mass spectrometry (LC/ESI-MS). The synthesis of seven novel quaternary nitrogen reagents is described. The derivatives are designed to be relatively small molecules to avoid some of the steric hindrance problems that may be associated with larger derivatisation reagents. The compounds have amine and carboxylic acid functional groups with which to derivatise carboxylic acids and amines, respectively. Two of the compounds contain a bromine atom in order to assess the advantages of a bromine isotope pattern in the mass spectra. This acts as a simple marker for derivatisation and enables data processing by cluster analysis.Activation of the carboxylic acid group was achieved by the use of either 1-chloro-4-methylpyridinium iodide (CMPI) or the more reactive 1-fluoro-4-methylpyridinium p-toluenesulphonate (FMP).1 Using both of these active reagents, the degree of nucleophilic substitution was investigated for the derivatisation of a variety of small molecules. Whilst giving some increase in the ESI-MS response for the derivatised compounds, the FMP itself acted as a derivatising reagent in a competing reaction. In the light of this finding, FMP was reacted with the test compounds separately and gave positive results as a derivatising reagent. Detection of the 'pre-charged' derivatives of amines and carboxylic acids by LC/ESI-MS was investigated with respect to their ESI response and chromatography.  相似文献   

13.
We developed a new method for the determination of the ethylene precursor 1-aminocyclopropane-1-carboxylic acid (ACC) using quantitative GC-negative chemical ionisation MS as a detection and quantification system, in combination with isotope dilution using [2H4]ACC and an off-line solid-phase extraction. By derivatisation with pentafluorobenzyl bromide, ACC could easily be detected with m/z 280 being the most abundant ion. Determination of this component resulted in a detection limit of 10 fmol and a linear fit in the 100 fmol-100 pmol range. The combination of a rapid, high yield purification method with a stable derivatisation procedure and a sensitive detection method allowed the detection of ACC in samples as low as 100 mg fresh mass.  相似文献   

14.
本文通过沉积在多孔硅表面的银纳米粒吸附对氨基苯硫酚和氨基的化学转化得到终端为Ni-Nα,Nα-二(羧甲基)-L-赖氨酸水合物-即 Ni-NTA体系的芯片。Ni-NTA修饰的芯片被用于从高浓度的盐和助溶剂的缓冲体系中亲和捕获组氨酸标记的融合蛋白:thioredoxin-urodilatin和SUMO-hu-aprotinin,并进行在线的MALDI-TOF质谱检测,克服了MALDI-TOF质谱中直接点样污染物妨碍样品与基质共结晶的问题,避免了繁琐的离线样品预处理。芯片在线分离、纯化和MALDI-TOF质谱分析体系有望在复杂或原始体液的溶液中分析目标分子。  相似文献   

15.
The potential of liquid chromatography combined with tandem mass spectrometry (LC/MS/MS) for the determination of pesticide metabolites in human urine at the sub-ppb level is explored. Metabolites from two organophosphorous pesticides, 4-nitrophenol (from parathion and parathion-methyl) and 3-methyl-4-nitrophenol (from fenitrothion), are taken as model analytes to conduct this study. After direct injection of the urine sample (10 microL), different approaches were evaluated in order to achieve correct quantitation of analytes using an electrospray ionisation (ESI) interface. Thus, the feasibility of using external calibration was checked versus the use of different isotope-labeled internal standards. The advantages of applying coupled-column liquid chromatography (LC/LC) as an efficient clean-up without any type of sample manipulation are also discussed. The combination of LC/LC with ESI-MS/MS allows the direct analysis of free metabolites in urine, as the automated clean-up performed by the coupled-column technique is sufficient for the removal of interferences that suppress the ionisation of analytes in the ESI source. Using this procedure with external calibration, good precision and recoveries, and detection limits below 1 ng/mL are reached with analysis run times of around 8 min. The hyphenated technique LC/LC/ESI-MS/MS is proved to be a powerful analytical tool, allowing the rapid, sensitive and selective determination of 4-nitrophenol and 3-methyl-4-nitrophenol in human urine without any sample treatment.  相似文献   

16.
Wang J  Ahmad H  Ma C  Shi Q  Vermesh O  Vermesh U  Heath J 《Lab on a chip》2010,10(22):3157-3162
We describe an automated, self-powered chip based on lateral flow immunoassay for rapid, quantitative, and multiplex protein detection from pinpricks of whole blood. The device incorporates on-chip purification of blood plasma by employing inertial forces to focus blood cells away from the assay surface, where plasma proteins are captured and detected on antibody "barcode" arrays. Power is supplied from the capillary action of a piece of adsorbent paper, and sequentially drives, over a 40 minute period, the four steps required to capture serum proteins and then develop a multiplex immunoassay. An 11 protein panel is assayed from whole blood, with high sensitivity and high reproducibility. This inexpensive, self-contained, and easy to operate chip provides a useful platform for point-of-care diagnoses, particularly in resource-limited settings.  相似文献   

17.
This work presents a new method to analyse simultaneously by GC–MS 31 pesticides from different chemical classes (2,4 D, 2,4 MCPA, alphacypermethrin, bifenthrin, bromoxynil, buprofezin, carbaryl, carbofuran, clopyralid, cyprodinil, deltamethrin dicamba, dichlobenil, dichlorprop, diflufenican, diuron, fenoxaprop, flazasulfuron, fluroxypyr, ioxynil, isoxaben, mecoprop-P, myclobutanil, oryzalin, oxadiazon, picloram, tau-fluvalinate tebuconazole, triclopyr, trifluralin and trinexapac-p-ethyl). This GC–MS method will be applied to the analysis of passive samplers (Tenax® tubes and SPME fiber) used for the evaluation of the indoor and outdoor atmospheric contamination by non-agricultural pesticides. The method involves a derivatisation step for thermo-labile or polar pesticides. Different agents were tested and MtBSTFA (N-(t-butyldimethylsilyl)-N-methyltrifluoroacetamide), a sylilation agent producing very specific fragments [M−57], was retained. However, diuron could not be derivatised and the isocyanate product was used for identification and quantification. Pesticides which did not need a derivatisation step were not affected by the presence of the derivatisation agent and they could easily be analysed in mixture with derivatised pesticides. The method can be coupled to a thermal-desorption unit or to SPME extraction for a multiresidue analysis of various pesticides in atmospheric samples.  相似文献   

18.
A new method for the analysis of alcohol ethoxylates (AEs) using electrospray ionisation liquid chromatography/mass spectrometry (ESI LC/MS) is described. The procedure incorporates a novel derivatisation step with phthalic anhydride for the analysis of EO0-20 ethoxylates in a single analysis. The derivatives obtained have proved to be very stable and the negative ion spectra show reduced background ions and competing adduct formation as compared to positive ion spectra. An automated solid phase extraction (SPE) step is used to allow both pre-concentration and clean-up of the environmental samples. The method provides more efficient recovery of AEs across the C12-C18 range than previously reported in the literature. Recoveries from final effluent spiked at 100 microg/L total AE, for the 126 species analysed, were found to be in the range 55-117%, with approximately 100 of the individual analytes having recoveries of 90-105%. An LOD of 0.02 microg/L for individual ethoxylate components is reported with the instrument operated in scan mode over the range m/z 300-1300. The method was applied to sewage effluent and influent samples, with AEs determined at approximately 7 and 5000 microg/L, respectively.  相似文献   

19.
A mass spectrometry based method for the simultaneous determination of an in vivo Greenford-Ware or 'GW cocktail' of CYP450 probe substrates and their metabolites in both human plasma and urine is described. The probe substrates, caffeine, diclofenac, mephenytoin, debrisoquine, chlorzoxazone and midazolam, together with their respective metabolites and stable isotope labelled internal standards, are simultaneously extracted from the biological matrix using solid phase extraction in 96-well microtitre plate format, automated by means of a custom built Zymark robotic system. The extracts are analysed by fast gradient high performance liquid chromatography (HPLC) with detection by tandem mass spectrometry (MS/MS) using thermally and pneumatically assisted electrospray ionisation in both positive and negative ion modes and selected reaction monitoring. The methods are specific, accurate and precise with intra- and inter-assay precision (%CV) of less than 15% for all analytes.  相似文献   

20.
The medical commission of the International Olympic Committee forbids the use of anabolic androgenic steroids to improve sporting performances. Nine anabolic steroids (androsterone (A), nandrolone, estradiol, testosterone propionate, nandrolone-17 propionate, dydrogesterone, testosterone, epitestosterone, boldenone) and alpha-cholestane as internal standard were studied by gas chromatography coupled with mass spectrometry (GC/MS). The derivatisation reagent employed for the derivatisation of anabolic steroids was a mixture of N-methyl-N-trimethylsilyltrifluoroacetamide (MSTFA), ammonium iodide and 2-mercaptoethanol (1000:2:6, v/w/v). Trimethylsilyl (TMS) derivatives were obtained. Anabolic steroids can be derivatised into one or two forms, mainly for androsterone into A-monoTMS and A-diTMS. The aim of this study was to research the optimization conditions of the derivatisation process (maximum yield of silylation reaction) of each anabolic steroid into only one form. A two-level factorial Doelhert design was used to determine the influence of different parameters and their interactions on each compound, thanks to response surface methodology. The parameters to be optimized were the reaction time and the temperature. The interaction "temperature-reaction time" is significant and has a positive effect on the improvement of the effectiveness of the derivatisation. Considering the large amount of information, often not convergent, a global desirability function was applied for multi-responses optimization. Thus, the optimized temperature and the reaction time of silylation were 85 degrees C and 24 min, respectively. Several GC/MS analytical parameters were also studied: linearity (regression coefficient upper than 0.99 for each compound, sensibility (range of concentration 0.05-0.30 microg/ml). Confirmatory experiments were applied to check the predicted values and to validate the model. The confirmatory assay responses are relatively close to the responses predicted. We observed satisfactory resolutions by GC/MS and a run lower than 12 min.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号