首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 390 毫秒
1.
This paper describes the fabrication and sensing characteristics of a self-assembled monolayer (SAM)-based surface plasmon resonance (SPR) immunosensor for detection of benzaldehyde (BZ). The functional sensing surface was fabricated by the immobilization of a benzaldehyde–ovalbumin conjugate (BZ–OVA) on Au-thiolate SAMs containing carboxyl end groups. Covalent binding of BZ–OVA on SAM was found to be dependent on the composition of the base SAM, and it is improved very much with the use of a mixed monolayer strategy. Based on SPR angle measurements, the functional sensor surface is established as a compact monolayer of BZ–OVA bound on the mixed SAM. The BZ–OVA-bound sensor surface undergoes immunoaffinity binding with anti-benzaldehyde antibody (BZ-Ab) selectively. An indirect inhibition immunoassay principle has been applied, in which analyte benzaldehyde solution was incubated with an optimal concentration of BZ-Ab for 5 min and injected over the sensor chip. Analyte benzaldehyde undergoes immunoreaction with BZ-Ab and makes it inactive for binding to BZ–OVA on the sensor chip. As a result, the SPR angle response decreases with an increase in the concentration of benzaldehyde. The fabricated immunosensor demonstrates a low detection limit (LDL) of 50 ppt (pg mL−1) with a response time of 5 min. Antibodies bound to the sensor chip during an immunoassay could be detached by a brief exposure to acidic pepsin. With this surface regeneration, reusability of the same sensor chip for as many as 30 determination cycles has been established. Sensitivity has been enhanced further with the application of an additional single-step multi-sandwich immunoassay step, in which the BZ-Ab bound to the sensor chip was treated with a mixture of biotin-labeled secondary antibody, streptavidin and biotin–bovine serum albumin (Bio–BSA) conjugate. With this approach, the SPR sensor signal increased by ca. 12 times and the low detection limit improved to 5 ppt with a total response time of no more than ca. 10 min. Figure A single-step multi-sandwich immunoassay step increases SPR sensor signal by ca. 12 times affording a low detection limit for benzaldehyde of 5 ppt  相似文献   

2.
Surface plasmon resonance (SPR) spectroscopy is used as a scaled-down, analytical, pseudo-chromatography tool for analyzing protein binding and elution over an ion-exchange surface under cyclic sorption conditions. A micrometric-scale adsorption surface was produced by immobilizing a typical ion exchange ligand – diethylaminoethyl (DEAE) – onto commercially available planar gold sensor chip surfaces pre-derivatized with a self-assembled monolayer of 11-mercaptoundecanoic acid with known density. An explicit mathematical formulation is provided for the deconvolution and interpretation of the SPR sensorgrams. An adsorption rate model is proposed to describe the SPR sensorgrams for bovine serum albumin, used here as model protein, when the DEAE surface is subjected to a cyclic series of binding and elution steps. Overall, we demonstrate that the adsorption rate model is capable of quantitatively describing BSA binding and elution for protein titers from dilute conditions up to overloaded conditions and a broad range of salt concentrations.  相似文献   

3.
A novel method to prepare surface plasmon resonance(SPR) sensor chips based on grafted imprinted polymer is explored. Benzophenone photografting system is used to grow molecularly imprinted polymer(MIP) films from the modified surface of gold substrate.The surface morphology and thickness of MIP films were investigated by scanning electronic microscope(SEM).The adsorption properties of sensor chip were studied by SPR spectroscopy.The results demonstrate that nano-MIP films can be constructed on the surface of gold substrate with the good adsorption of template molecules.  相似文献   

4.
A surface plasmon resonance (SPR) based biosensor was developed for monitoring 2,4-dichlorophenol, a known dioxin precursor, using an indirect competitive immunoassay. The SPR sensor was fabricated by immobilizing a gold-thin layer on the surface of an SPR sensor chip with an anti-(2,4-dichlorophenol) antibody using a gold binding polypeptide (GBP) and protein G. The SPR response based on the antigen-antibody reaction in a flow system was measured by injecting a 2,4-dichlorophenol sample solution into the flow system in which the SPR sensor was located. In a direct immunoassay system using the modified sensor chip, no significant SPR angle shift less than 0.001° was observed when a 25 ppm of 2,4-dichlorophenol solution was injected. In order to improve the sensitivity of the SPR sensor, an indirect competitive immunoassay method was used in conjunction with the SPR sensor system using 2,4-dichlorophenol conjugated with bovine serum albumin (BSA). In the competitive assay, a 350 ppm 2,4-dichlorophenol-BSA conjugate solution containing 2,4-dichlorophenol at various concentrations (10-250 ppb) were injected into the SPR sensor system. The sensitivity of this indirect immunoassay was found to be extremely sensitive, compared to the direct one, and a detection limit of 20 ppb was estimated. Verification that the use of GBP for immobilizing the antibody on the sensor chip enhanced the sensitivity to 2,4-dichlorophenol was obtained by comparing the procedure with another modification, in which BSA was used instead of GBP for immobilizing the antibody on the sensor chip. The affinity constant of 2,4-dichlorophenol and its conjugate to the antibody were estimated form the SPR response.  相似文献   

5.
Dissociation of biotin from streptavidin is very difficult due to their high binding affinity. The re-use of streptavidin-modified surfaces is therefore almost impossible, making devices containing them (e.g. surface plasmon resonance (SPR) sensor chips) expensive. This paper describes a new protocol for reversible and site-directed immobilization of proteins with streptavidin affinity tags on the streptavidin-coated SPR biosensor chip (SA chip). Two streptavidin affinity tags, nano-tag and streptavidin-binding peptide (SBP tag), were applied. They both can specifically interact with streptavidin but have weaker binding force compared to the biotin–streptavidin system, thus allowing association and dissociation under controlled conditions. The SA chip surface could be regenerated repeatedly without loss of activity by injection of 50 mM NaOH solution. The fusion construct of a SBP tag and a single-chain antibody to mature bovine prion protein (scFv-Z186-SBP) interacts with the SA chip, resulting in a single-chain-antibody-modified surface. The chip showed kinetic response to the prion antigen with equilibrium dissociation constant K D≈4.01×10−7. All results indicated that the capture activity of the SA chip has no irreversible loss after repeated immobilization and regeneration cycles. The method should be of great benefit to various biosensors, biochips and immunoassay applications based on the streptavidin capture surface.  相似文献   

6.
We report the multiplexed, simultaneous analysis of antigen–antibody interactions that involve human immunoglobulin G (IgG) on a gold substrate by the surface plasmon resonance imaging method. A multichannel, microfluidic chip was fabricated from poly(dimethylsiloxane) (PDMS) to selectively functionalize the surface and deliver the analyte solutions. The sensing interface was constructed using avidin as a linker layer between the surface-bound biotinylated bovine serum albumin and biotinylated anti-human IgG antibodies. Four mouse anti-human IgG antibodies were selected for evaluation and the screening was achieved by simultaneously monitoring protein–protein interactions under identical conditions. Antibody–antigen binding affinities towards human immunoglobulin were quantitatively compared by employing Langmuir adsorption isotherms for the analysis of SPRi responses obtained under equilibrium conditions. We were able to identify two IgG samples with higher affinities towards the target, and the determined binding kinetics falls within the typical range of values reported in the literature. Direct measurement of proteins in serum samples by SPR imaging was achieved by developing methods to minimize nonspecific adsorption onto the avidin-functionalized surface, and a limit of detection (LOD) of 6.7 nM IgG was obtained for the treated serum samples. The combination of SPR imaging and multichannel PDMS chips offers convenience and flexibility for sensitive and label-free measurement of protein–protein interactions in complex conditions and enables high-throughput screening of pharmaceutically significant molecules. Figure Microchannel SPR imaging for protein–protein interactions  相似文献   

7.
A surface plasmon resonance (SPR) immunosensor based on a competitive immunoreaction for the determination of trinitrophenol (TNP) is described. A goat anti-mouse IgG (1st antibody), which recognizes an Fc moiety of an antibody, was immobilized on a gold film of an SPR sensor chip by physical adsorption. A TNP solution containing a fixed concentration of a mouse anti-TNP monoclonal antibody (2nd antibody) and a TNP-keyhole limpet hemocyanin (KLH) conjugate was incubated in one-pot and introduced into the sensor chip. The TNP-KLH conjugate competes with TNP for binding with the 2nd antibody. The resulting complex of the 2nd antibody with the TNP-KLH conjugate was bound to the 1st antibody, which is immobilized on the sensor chip. The SPR sensor signal based on resonance angle shift is dependent on the concentration of TNP in the incubation solution in the range from 25 ppt to 25 ppb, and the coefficient of variation of the SPR signals for the 25 ppb TNP solution was determined to be 13% (n = 4). The experimental results for the adsorption constant of the 1st antibody on the sensor chip and the binding constant of the 1st antibody complex with the 2nd antibody are discussed, together with theoretical considerations.  相似文献   

8.
Monolayers of metal complexes were covalently attached to the surface of lamellar SPR interfaces (Ti/Ag/a-Si(0.63)C(0.37)) for binding histidine-tagged peptides with a controlled molecular orientation. The method is based on the activation of surface acid groups with N-hydroxysuccinimide (NHS), followed by an amidation reaction with (S)-N-(5-amino-1-carboxypentyl)iminodiacetic acid (NTA). FTIR and X-ray photoelectron spectroscopy (XPS) were used to characterize each surface modification step. The NTA modified SPR interface effectively chelated Cu(2+) ions. Once loaded with metal ions, the modified SPR interface was able to bind specifically to histidine-tagged peptides. The binding process was followed by surface plasmon resonance (SPR) in a droplet based configuration. The Cu(2+)-NTA modified interface showed protein loading comparable to commercially available NTA chips based on dextran chemistry and can thus be regarded as an interesting alternative. The sensor interface can be reused several times due to the easy regeneration step using ethylenediaminetetraacetic acid (EDTA) treatment.  相似文献   

9.
《Analytical letters》2012,45(3):499-507
Regeneration of the sensor chip surface is difficult in many surface plasmon resonance (SPR) biosensor assays. Improper regeneration will reduce life span of the sensor chip and decrease the quality of the data. Considering the advantages of reducing the regeneration frequency, a theoretically feasible continuous SPR biosensor immunoassay for sulfamethazine (SMT) was developed. In the continuous inhibitive immunoassay, the sensor chip surface is regenerated only once after a definite number of tests instead of every test. The SMT-bovine serum albumin (BSA) conjugate was covalently immobilized to a carboxymethyldextran modified gold film. The immobilization conditions of the antigen were studied and the working dilution of the antibody was optimized. The antibody was mixed with SMT of different concentrations prepared with PBS buffer to construct the calibration curve. The limit of detection was 0.5 ng mL?1. The continuous SPR biosensor assay was proved to be simpler and more practical than a normal one.  相似文献   

10.
We show that the antigen CFP-10 (found in tissue fluids of tuberculosis patients) can be used as a marker protein in a surface-plasmon resonance (SPR) based method for early and simplified diagnosis of tuberculosis. A sandwich SPR immunosensor was constructed by immobilizing the CFP-10 antibody on a self-assembled monolayer on a gold surface, this followed by blocking it with bovine serum albumin. Following exposure of the sensor surface to a sample containing CFP-10, secondary antibody immobilized on nickel oxide nanoparticles are injected which causes a large SPR signal change. The method has a dynamic range from 0.1 to around 150 ng per mL of CFP-10, and a detection limit as low as 0.1 ng per mL. This is assumed to be due to the high amplification power of the NiO nanoparticles.
Figure
Schematic diagram of sensor chip configuration (left) and SPR study based on amplification strategy with NiO nanoparticles (right).  相似文献   

11.
A novel low-cost platform to assess biomolecular interactions was investigated using surface plasmon resonance and an aptamer-based assay for thrombin detection. Gold SPR surface functionalized with a carboxylated cross-linked BSA film (cBSA) and commercially available carboxymethylated dextran chip (CM5) were used as immobilization platforms for the thrombin binding aptamer. The high end commercial instrument Biacore 3000 and a custom made FIA set-up involving TI Spreeta sensor (TSPR2K23) were used to assess different concentrations of thrombin within the range 0.1-150 nM both in buffer and in a complex matrix (plasma) using the obtained aptasensors. Based on data derived from both CM5 and cBSA platforms, the cBSA aptasensor exhibited good selectivity, stability and regeneration ability, both in buffer and in complex matrices (plasma), comparable with CM5.  相似文献   

12.
A surface plasmon resonance (SPR) biosensor for the detection of microcystins (MCs) in drinking water has been developed. Several assay formats have been evaluated. The selected format is based on a competitive inhibition assay, in which microcystin-LR (MCLR) has been covalently immobilized onto the surface of an SPR chip functionalized with a self-assembled monolayer. The influence of several factors affecting sensor performance, such as the nature and concentration of the antibody, the composition of the carrier buffer, and the blocking and regeneration solutions, has been evaluated. The optimized SPR biosensor provides an IC50 0.67 ± 0.09 μg L−1, a detection limit of 73 ± 8 ng L−1, and a dynamic range from 0.2 to 2.0 μg L−1 for MCLR. Cross-reactivity to other related MCs, such as microcystin-RR (88%) and microcystin-YR (94%), has also been measured. The SPR biosensor can perform four simultaneous determinations in 60 min, and each SPR chip can be reused for at least 40 assay–regeneration cycles without significant binding capacity loss. The biosensor has been successfully applied to the direct analysis of MCLR in drinking water samples, below the provisional guideline value of 1 μg L−1 established by the World Health Organization for drinking water.  相似文献   

13.
A surface plasmon resonance (SPR)-immunosensor for detection of the low molecular weight compound 2,4-dinitorophenol (DNP) at ultra-low concentration has been developed. The sensor strategy is based on a competitive immunoreaction between DNP and a DNP-protein conjugate, namely DNP-bovine serum albumin conjugate (DNP-BSA). Anti-DNP monoclonal antibody was immobilized on a gold thin-film coated SPR-sensor chip by means of a chemical coupling process. DNP-BSA, on contact with the anti-DNP antibody immobilized SPR-immunosensor chip causes an increase in the resonance angle of the sensor chip. The optimum concentration of immobilized antibody on the SPR-sensor chip is 100 μg mL−1. The SPR-immunosensor response for free DNP determination using the competitive immunoreaction had a response time of ca. 15 min. Using this method, DNP could be determined in the concentration range 1 ppt to 1 ppb. The SPR signal for ppt levels of DNP was enhanced by a factor of three by subsequently treating immuno-bound DNP-BSA with a secondary anti-DNP antibody.  相似文献   

14.
Sensors able to provide ‘yes’/‘no’ answers have become of interest in recent years, especially in the fields of environmental research and healthcare. We describe a procedure based on surface plasmon resonance imaging (SPRI) to investigate the interaction between mucin and anti-mucin antibody, and we outline the development of an alarm sensor for the protein mucin, whose high concentration in saliva, blood or tissue is related to illnesses such as gingivitis, peridontitis or even cancer. Anti-mucin gastric antibodies are immobilised onto a gold surface. The immobilisation is evaluated for neat gold chips and for polymer-modified gold surfaces. We found that two different pHs are required, one for the immobilisation of the antibodies on gold (pH 5.5) and a different one for optimal interaction between the sample and the antibody layer (pH 7.0). Finally, we briefly demonstrate the application of the sensor to real saliva samples, both mucin-less and mucin-containing, evaluating the potential of the sensor to discriminate between healthy and ill.  相似文献   

15.
In this paper, we report surface-initiated d(A-T) polymerization by Taq DNA polymerase as a method for constructing DNA-tethered surfaces using an enzyme. The enzymatic polymerization was conducted successfully via two steps: tethering of oligo d(A-T)s onto the surface presenting carboxylic acids by amide coupling and surface-initiated polymerization using Taq DNA polymerase. In this enzymatic polymerization process, the design and construction of carboxylic acid-presenting surfaces were found to be an important factor: DNA growth did not occur on the gold surface coated only with the self-assembled monolayer (SAM) of 16-mercaptohexadecanoic acid (MHDA), but effectively proceeded on the surfaces presenting mixed SAMs of MHDA and 1-pentadecanethiol. The coupling of oligo d(A-T)s and the subsequent DNA polymerization reaction were characterized by polarized infrared external reflectance spectroscopy, ellipsometry, X-ray photoelectron spectroscopy, and atomic force microscopy.  相似文献   

16.
A new immunoassay for continuously monitoring atrazine in water has been developed. It uses a portable biosensor platform based on surface plasmon resonance (SPR) technology. This immunoassay is based on the binding inhibition format with purified polyclonal antibodies, with the analyte derivative covalently immobilized on a gold sensor surface. An alkanethiol self-assembled monolayer (SAM) was formed on the gold-coated sensor surface in order to obtain a reusable sensing surface. The low detection limit for the optimized assay, calculated as the concentration that produces a 10% decrease in the blank signal, is 20 ng/L. A complete assay cycle, including regeneration, is accomplished in 25 min. Additionally, a study of the matrix effects of different types of wastewater was performed. All measurements were carried out with the SPR sensor system (β-SPR) commercialised by the company Sensia, S.L. (Spain). The small size and low response time of the β-SPR platform would allow it to be used in real contaminated locations. The immunosensor was evaluated and validated by measuring the atrazine content of 26 natural samples collected from Ebro River. Solid-phase extraction followed by gas chromatography coupled to mass spectrometric detection (SPE–GC–MS) was used to validate the new immunoassay.  相似文献   

17.
《Analytical letters》2012,45(4):640-648
Abstract

A highly sensitive surface plasmon resonance immunosensor for the determination of linear alkylbenzene sulfonate (LAS) was fabricated. The method is based on an indirect competitive reaction of an anti‐LAS antibody in a sample solution with LAS immobilized on a sensor chip and with LAS in the sample solution. A sensor chip immobilized with LAS was prepared by utilizing an electrostatic interaction between an LAS conjugate, LAS–horseradish peroxidase (LAS‐HRP), and a self‐assembled monolayer of 11‐amino‐1‐undecanethiol hydrochloride, which was preliminary prepared on a gold thin film of the sensor chip. The quantitative determination of LAS in the concentration range 10–1000 ppb was achieved by using the proposed immunosensor.  相似文献   

18.
This paper describes the formation of a self-assembled monolayer of 11-mercaptoundecanoic acid (MUA) under different concentrations on a gold sensor disk, monitoring in situ and in real time using surface plasmon resonance spectroscopy (SPR). The film thickness and dielectric constant were determined for a fully formed monolayer using one-color approach SPR. The kinetic studies of the film formation in ethanol solution indicated that the self-assembled monolayer is formed in a two-step adsorption process. In this sense, this unpublished route was applied on the basis of a model where many molecules are adsorbed at an initial step and then can be desorbed and/or rearranged to form a perfect monolayer.  相似文献   

19.
A monoclonal antibody for the carcinoembryonic antigen (CEA) was immobilized on a gold chip surface covered by a self-assembled monolayer of 11-mercaptoundecanoic acid. Upon the addition of CEA, a Fourier transform infrared reflection-absorption spectroscopy (FT-IR RAS) measurement showed an increased absorption at around 1500 - 1700 cm(-1), corresponding to its amide structures. Another addition of CEA polyclonal antibody on this chip caused a further increase of the absorption in this region only after a treatment with CEA. This result shows that an antibody-fixed gold surface coupled with an FT-IR RAS measurement provides a new tool for detecting the antibody-antigen interaction.  相似文献   

20.
Wang J  Wang F  Xu Z  Wang Y  Dong S 《Talanta》2007,74(1):104-109
Through electrostatic layer-by-layer (LbL) assembly, negatively charged calf thymus double stranded DNA (CTds-DNA), and positively charged Zr4+ ions were alternately deposited on gold substrate modified with chemisorbed cysteamine. Thus-prepared three-dimensional DNA networks were characterized by surface plasmon resonance (SPR) spectroscopy, X-ray photoelectron spectroscopy (XPS) and infrared reflection-absorption spectroscopy (IR-RAS). SPR spectroscopy indicates that the effective thickness of DNA monolayer in the (DNA/Zr4+)1 bilayer was 1.5 ± 0.1 nm, which corresponds to the surface coverage of 79% of its full packed monolayer. At the same time, a linear increase of film thickness with increasing number of layers was also confirmed by SPR characterizations. The data of XPS and IR-RAS show that Zr4+ ions interact with both the phosphate groups and nitrogenous bases of DNA and load into the framework of DNA. Furthermore, the interactions between this composite film and heme protein cytochrome c (Cyt c) were investigated by SPR spectroscopy and electrochemistry. Compared with the adsorption of Cyt c on DNA monolayer, this composite multilayer film can obviously enhance the amount of immobilized Cyt c confirmed by SPR reflectivity-incident angle (R-θ) curves. Cyclic voltammetry (CV) indicates the Cyt c adsorbed on the composite film is electroactive, and the enhancement of peak current in CV indirectly verifies the increase of the amount of immobilized Cyt c.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号