Bo T  Wiedmer SK  Riekkola ML 《Electrophoresis》2004,25(12):1784-1791
A phospholipid coating with lysozyme as chiral recognition reagent permeated into the phospholipid membrane was developed for the chiral capillary electrophoretic (CE) separation of D- and L-tryptophan. As a kind of carriers, coated as phospholipid membranes onto the inner wall of a fused-silica capillary, liposomes are able to interact with basic proteins such as lysozyme, which may reside on the surface of the phospholipid membrane or permeate into the middle of the membrane. The interaction results in strong immobilization of lysozyme in the capillary. Coatings prepared with liposomes alone did not allow stable immobilization of lysozyme into the phospholipid membranes, as seen from the poor repeatability of the chiral separation. When 1-(4-iodobutyl)-1,4-dimethylpiperazin-1-ium iodide (M1C4) was applied as a first coating layer in the capillary, the electroosmotic flow (EOF) was effectively suppressed, the phospholipid coating was stabilized, and the lysozyme immobilization was much improved. The liposome composition, the running buffer, and the capillary inner diameter all affected the chiral separation of D- and L-tryptophan. Coating with 4 mM M1C4 and then 1 mM phosphatidylcholine (PC)/phosphatidylserine (PS) (80:20 mol%), with 20 mM (ionic strength) Tris at pH 7.4 as the running buffer, resulted in optimal chiral separation with good separation efficiency and resolution. Since lysozyme was strongly permeated into the membrane of the phospholipids on the capillary surface, the chiral separation of D- and L-tryptophan was achieved without lysozyme in the running buffer. The effects of different coating procedures and separation conditions on separation were evaluated, and the M1C4-liposome and liposome-lysozyme interactions were elucidated. The usefulness of protein immobilized into phospholipid membranes as a chiral selector in CE is demonstrated for the first time.  相似文献   

2.
A novel positively charged polymer of quaternary ammonium substituted agarose (Q-agarose) has been synthesized and explored for use as a coating in capillary electrophoresis. The fast and simple coating procedure is based on a multi-site electrostatic interaction between the polycationic agarose polymer and the negatively charged fused-silica surface. By simply flushing fused-silica capillaries with hot polymer solution a positively charged, hydrophilic deactivation layer is achieved. The polymer surface provides an intermediate electroosmotic flow of reversed direction, over a range of pH 2-11, compared to unmodified fused-silica. The coating procedure was highly reproducible with an RSD of 4%, evaluated as the electroosmotic flow mobility for 30 capillaries prepared at 10 different occasions. The application of Q-agarose coated capillaries in separation science was investigated using a set of basic drugs and model proteins and peptides. Due to the intermediate electroosmotic flow generated, the resolution of basic drugs could be increased, compared to using bare fused-silica capillaries. Moreover, the coating enabled separation of proteins and peptides with efficiencies up to 300.000 plates m(-1).  相似文献   

3.
Piperazine-based derivatives, including 1-(2-pyridyl)piperazine (2-PP), 1-(2-pyrimidyl)piperazine (2-PMP), 1-(4-pyridyl)piperazine (4-PP), and 1-(1-methyl-4-piperidinyl)piperazine (M-PP), were used for the derivatization of carboxyl groups on peptides with 1-(3-dimethylaminopropyl)-3-ethylcarbodiimide hydrochloride (EDC) and 1-hydroxy-7-azabenzotriazole (HOAt) as coupling reagents, and trifluoroacetic acid (TFA) as activator. Taking synthetic peptides RVYVHPI (RI-7) and APGDRIYVHPF (AF-11) as samples, the yields of derivatized peptides by 2-PP, 2-PMP and 4-PP were higher than 94%. The effect of piperazine derivatives on the signals of tryptic digests of α-transferrin and bovine serum albumin (BSA) was investigated, and it was found that peptides derivatized by 2-PP and 2-PMP exhibited obviously improved ionization efficiency. Furthermore, comparison of identified peptides before and after derivatization showed that peptides with low molecular weight (MW) and high pI value were preferably detected after derivatization. In addition, after derivatization with 2-PP and 2-PMP, protein myelin basic protein S, 20 kDa protein, and histone H were confidently identified from the tryptic digests of two fractions of rat brain protein separated by reversed-phase high-performance liquid chromatography (HPLC), indicating the potential application of 2-PP and 2-PMP for the highly sensitive determination of peptides in comprehensive proteome analysis.  相似文献   

4.
A method for coating capillaries for capillary electrophoresis with chemically bonded polydimethylacrylamide has been developed, and the properties of the capillaries have been evaluated. The coated capillaries provided high separation efficiency, 12 x 10(5) theoretical plates/m was obtained for cytochrome c. The electroosmotic flow at pH 8.0 was 10 x 10(-10) to 6 x 10(-10) m2 V(-1) s(-1). The coated capillaries were quite stable at high pH. At least 150 runs could be done at pH 10 without appreciable performance deterioration. The excellent performance of the coated capillaries was illustrated by separation of basic proteins, acidic proteins, 9-fluorenylmethyl chloroformate-derivatized neurotransmitter amino acids, peptide reference mixtures and peptides digested from a bacteria protein.  相似文献   

5.
A new type of capillary column for open-tubular electrochromatography   总被引:1,自引:0,他引:1  
Zhao Y  Zhao R  Shangguan D  Liu G 《Electrophoresis》2002,23(17):2990-2995
A new type of open-tubular C(18) ester-bonded electrochromatographic column was prepared with sol-gel technology, followed by an on-column octadecyl silylation reaction. Glycidoxypropyltrimethoxysilane, a widely used and important silane agent, was used as the sol-gel precursor to form a thin coating layer on the wall of the fused-silica capillary. The C(18) groups were introduced into the coating layer by on-column esterification reaction with stearic acid. The electrochromatography behavior of the column was evaluated in terms of the separation of peptides. A high efficiency of 4.8x10(5) plates/m was achieved for a basic pentapeptide using the C(18 )ester-bonded column. In comparison with bare capillaries and glycidoxypropyltrimethoxysilane sol-gel-coated capillaries, the C(18) ester-bonded column showed the best separation of a mixture of seven pentapeptides under identical conditions of buffer, pH, and applied voltage.  相似文献   

6.
Two compounds, derivatives of 1,4-diazobicyclo[2,2,2]octane (DABCO), have been evaluated as potential quenchers of silanol interactions with peptides and proteins during their capillary zone electrophoresis (CZE) separations. They are: 1-(4-iodobutyl)4-aza-1-azoniabicyclo[2,2,2]octane iodide (M7C4I) and 1,4-didecyl-1,4-diazoniabicyclo [2,2,2]octane dibromide (C10M7C10). The first compound is known to react with the wall, by forming a covalent bond via alkylation of silanols. On the contrary, the second one (C10M7C10) can only loosely interact with silica due to lack of reactive iodine and to a much too short distance (a C(2)) between the two quaternary nitrogens. Very good peptide maps of protein digests can be obtained in isoelectric glutamic acid (Glu) buffer, at pH 3.52 by utilizing the M7C4I. However, in the case of total tissue extracts, excellent resolution is obtained only with the first eluting part of the analyte spectrum (i.e., peptides and smaller proteins). With larger proteins, interaction with the wall and loss of resolution is experienced. When using the C10M7C10, good resolution of di- and tripeptides is obtained, while a loss of resolution is observed with entire protein digest. M7C4I does not seem to interact with the peptide/protein analytes, and simply repels them from the wall via its positive charges; it is believed that disalt (C10M7C10) acts by interacting with the same compounds, possibly by forming micelles in solution.  相似文献   

7.
This investigation describes the separation of tryptic peptides by capillary reversed-phase high-performance liquid chromatography (RP-HPLC) with eluents in the intermediate pH range, followed by in-line electrospray ionisation tandem mass spectrometry (ESI-MS/MS) analysis. For these purposes, gradient elution procedures with an aqueous eluent containing 20 mM ammonium formate, and an increasing content of acetonitrile or methanol, were employed. Compared to the analysis of the same tryptic peptides under low-pH conditions with an ion-pairing reagent, the increase in the pH with the 20 mM ammonium formate mobile phase led to significant changes in both peptide retention to the reversed-phase column and the collision-induced dissociation at the MS/MS stage as a consequence of the changes in the physico-chemical properties of these peptides, such as their overall charge, polarity and relative hydrophobicity. Thus, improved selectivity for the peptide separation and favourable tandem mass spectrometry analysis could be obtained with eluents in this intermediate pH range. The number of tryptic peptides identified by the new approach for the proteins investigated were significantly higher than that obtained by the conventional low-pH methods. Moreover, analysis of protein digests at very low concentrations was also performed under both acidic and intermediate pH conditions and similar improvements in selectivity and MS/MS detection limits were observed, i.e. identification of more distinct peptides and higher sequence coverage of the protein was obtained when eluents of intermediate pH were employed. This study therefore highlights the potential of conducting peptide mapping in the intermediate pH range to achieve more reliable and sensitive protein identifications with capillary RP-HPLC–ESI-MS/MS.  相似文献   

8.
A bottom-up proteomic approach, based on capillary electrophoresis (CE) in combination with matrix- assisted laser desorption/ionization tandem time-of-flight mass spectrometry (MALDI-ToF/ToF MS), was used to analyze immunoaffinity depleted human cerebrospinal fluid (CSF) and compare it with a non-depleted sample. After enzymatic digestion and desalting, the tryptic peptides were separated by CE using PolyE-323 modified capillaries and fractionated off-line onto MALDI target plates for further analysis by MALDI-MS and MS/MS. The protein profile of the depleted sample was compared with non depleted CSF. Overall, 85 proteins were identified with 95% significance in both samples. The significance scores for proposed biomarkers, such as amyloid-like protein 1 precursor, could be increased up to 12 times after the depletion. Other proteins, often suggested to be related to neurodegenerative diseases, like amyloid beta A4 protein precursor, superoxide dismutase and apolipoprotein E precursor could only be found in the depleted CSF samples. The effect of a derivatization of tryptic peptides with 2- methoxy-4,5-dihydro-1H-imidazole reagent for protein identification with MS was also employed to increase the number of identified proteins and the sequence coverages. The results presented in this study illustrate the benefit of combining a sample pre-fractionation step and a label's ability to enhance the ionization efficiency with the potential of CE using PolyE-323 modified capillaries in the analysis of complex samples. The straight-forward approach that provides speed and simplicity resulting in high-resolution separations and low sample consumption represents an easily applicable separation technique that can serve as a complement to other currently existing analytical approaches needed in modern proteomic analysis of clinically relevant samples.  相似文献   

9.
Six amino acids with pIs that ranged from 3.2 to 9.7 were used as ampholytes to establish a pH gradient in capillary isoelectric focusing. This amino acid-based capillary isoelectric focusing (cIEF) was coupled with ESI-MS/MS using an electrokinetically pumped sheath-flow interface for peptide analysis. Amino acid-based isoelectric focusing generates a two-order of magnitude lower background signal than commercial ampholytes in the important m/z range of 300–1800. Good focusing was achieved for insulin receptor, which produced ∼10 s peak width. For 0.1 mg mL−1 bovine serum albumin (BSA) digests, 24 ± 1 peptides (sequence coverage 47 ± 4%) were identified in triplicate analysis. As expected, the BSA peptides were separated according to their pI. The concentration detection limit for the BSA digests is 7 nM and the mass detection limit is 7 fmole. A solution of six bovine protein tryptic digests spanning 5 orders of magnitude in concentration was analyzed by amino acid based cIEF-ESI-MS/MS. Five proteins with a concentration range spanning 4 orders of magnitude were identified in triplicate runs. Using amino acid based cIEF-ESI-MS/MS, 112 protein groups and 303 unique peptides were identified in triplicate runs of a RAW 264.7 cell homogenate protein digest. In comparison with ampholyte based cIEF-ESI-MS/MS, amino acid based cIEF-ESI-MS/MS produces higher resolution of five acidic peptides, much cleaner mass spectra, and higher protein spectral counts.  相似文献   

10.
利用羟丙基纤维素溶液动态涂层技术修饰毛细管管壁,改善了分离效率.在不影响质谱检测的条件下,将动态涂层毛细管电泳与质谱检测联用,有效地提高了对蛋白质的鉴定能力.将该技术应用于对复杂蛋白质样品的酶解产物的分析鉴定,结果令人满意.  相似文献   

11.
Wu X  Wei W  Su Q  Xu L  Chen G 《Electrophoresis》2008,29(11):2356-2362
1-Butyl-3-methylimidazolium tetrafluoroborate ionic liquids (1B-3MI-TFB ILs) were employed as a coating material and BGE in CE for simultaneous separation of basic and acidic proteins such as lysozyme, cytochrome C, ribonuclease A, albumin, and alpha-lactalbumin. 1B-3MI-TFB ILs effectively reversed the surface charges on the capillary inner surface, preventing the adsorption of positively charged proteins onto the silica surface, as well as associated with proteins, thus benefiting the separation efficiencies and reproducibility. Consequently, simultaneous baseline separation of five proteins was achieved within 14 min by using 10 mM of 1B-3MI-TFB ILs as dynamic coating and the only running electrolyte at the voltage of +20 kV. The proposed coating technique is simple, less time-consuming, reproducible, and also stable enough for proteins separation without the need of additives. Symmetrical peaks with efficiencies up to 670,000 plates/m were obtained. Recoveries of proteins with RSD (for migration times) of 0.23-0.42% (run-to-run) and 2.5-3.8% (day-to-day) were achieved, respectively. The applicability of the proposed method in proteins separation was evaluated by the separation of egg white samples.  相似文献   

12.
To simplify capillary electrophoresis-mass spectrometry (CE-MS) operation, a background electrolyte (BGE) containing a polymer additive is introduced that allows the analysis of peptides and protein mixtures in underivatized fused-silica capillaries without any pretreatment, thereby increasing throughput. The most important characteristic of these polymer additives is that they do not significantly suppress the signals of the proteins and peptides under electrospray ionization, thereby allowing them to be used as an additive to common BGEs that are used for CE-MS analysis of peptide and protein mixtures. In addition, because the fused-silica capillary inner wall is continuously coated with the polymer additive, migration irreproducibility, due to the degradation of the capillary inner wall coating, under CE-MS is minimized. High sensitivity of detection, migration reproducibility, and ease of fabrication allow CE-MS analyses that require long analysis time, such as (CE-MS/MS)n, to be performed with ease. The utility of this background electrolyte has been demonstrated for the analysis of complex protein digests and intact proteins.  相似文献   

13.
High-efficiency peptide analysis using multimode pressure-assisted capillary electrochromatography/capillary electrophoresis (pCEC/pCE) monolithic polymeric columns and the separation of model peptide mixtures and protein digests by isocratic and gradient elution under an applied electric field with UV and electrospray ionization-mass spectrometry (ESI-MS) detection is demonstrated. Capillary multipurpose columns were prepared in silanized fused-silica capillaries of 50, 75, and 100 microm inner diameters by thermally induced in situ copolymerization of methacrylic monomers in the presence of n-propanol and formamide as porogens and azobisisobutyronitrile as initiator. N-Ethylbutylamine was used to modify the chromatographic surface of the monolith from neutral to cationic. Monolithic columns were termed as multipurpose or multimode columns because they showed mixed modes of separation mechanisms under different conditions. Anion-exchange separation ability in the liquid chromatography (LC) mode can be determined by the cationic chromatographic surface of the monolith. At acidic pH and high voltage across the column, the monolithic stationary phase provided conditions for predominantly capillary electrophoretic migration of peptides. At basic pH and electric field across the column, enhanced chromatographic retention of peptides on monolithic capillary column made CEC mechanisms of migration responsible for separation. The role of pressure, ionic strength, pH, and organic content of the mobile phase on chromatographic performance was investigated. High efficiencies (exceeding 300 000 plates/m) of the monolithic columns for peptide separations are shown using volatile and nonvolatile, acidic and basic buffers. Good reproducibility and robustness of isocratic and gradient elution pressure-assisted CEC/CE separations were achieved for both UV and ESI-MS detection. Manipulation of the electric field and gradient conditions allowed high-throughput analysis of complex peptide mixtures. A simple design of sheathless electrospray emitter provided effective and robust low dead volume interfacing of monolithic multimode columns with ESI-MS. Gradient elution pressure-assisted mixed-mode separation CE/CEC-ESI-MS mass fingerprinting and data-dependent pCE/pCEC-ESI-MS/MS analysis of a bovine serum albumin (BSA) tryptic digest in less than 5 min yielding high sequence coverage (73%) demonstrated the potential of the method.  相似文献   

14.
We report the use of a sheath flow reactor for post-column fluorescence derivatization of proteins. The derivatization reaction employed naphthalene-2,3-dicarboxaldehyde (NDA) and beta-mercaptoethanol, which were added in the sheath buffer. The labeled proteins were detected by laser-induced fluorescence with an argon-ion laser beam at 488 nm. The performance of this detection scheme was evaluated by separation of some protein standards. A column efficiency of 450,000 plates/m was obtained without stacking. The limits of detection for those standard proteins were determined to be from 8 to 32 nM. Excellent linear relationship was obtained with correlation coefficient of 0.9998 for alpha-lactalbumin concentration ranging from 3.91 x 10(-7) to 1.25 x 10(-5) M. Separation of protein standards at low pH was also demonstrated by reversing the electroosmotic flow (EOF) with addition of cetyltrimethylammonium bromide (CTAB) to the running buffer. Different separation selectivity was achieved, but the sensitivity is poorer than that at high pH. This post-column derivatization detection system was applied successfully to analyze the protein extract from HT29 human colon cancer cells as well as tryptic peptides.  相似文献   

15.
Yoo C  Pal M  Miller FR  Barder TJ  Huber C  Lubman DM 《Electrophoresis》2006,27(11):2126-2138
A method is developed toward high sequence coverage of proteins isolated from human breast cancer MCF10 cell lines using a 2-D liquid separations. Monolithic-capillary columns prepared by copolymerizing styrene with divinylbenzene are used to achieve high-resolution separation of peptides from protein digests. This separation is performed with minimal sample preparation directly from the 2-D liquid fractionation of the cell lysate. The monolithic column separation is directly interfaced to ESI-TOF MS to obtain a peptide map. The protein digests were also analyzed by MALDI-TOF MS and an accurate M(r) of the intact protein was obtained using an HPLC-ESI-TOF MS. The result is that these techniques provide complementary information where nearly complete sequence coverage of the protein is obtained and can be compared to the experimental M(r) value. The high sequence coverage provides information on isoforms and other post-translational modifications that would not be available from methods that result in low sequence coverage. The results from the use of monolithic columns are compared to that obtained by CE-MS. The monolithic column separations provide a rugged and highly reproducible method for separating protein digests prior to MS analysis and is suited to confidently identify biomarkers associated with cancer progression.  相似文献   

16.
A procedure for enhanced capillary electrophoresis-electrospray ionization-mass spectrometry (CE-ESI-MS) of proteins is presented. The use of a newly presented capillary coating, PolyE-323, provided fast separations of typically a few minutes with high efficiency, good deactivation, and no bleeding into the mass spectrometer. Capillaries coated with PolyE-323 showed high stability over a range of pH 2-10, and tolerance towards methanol and acetonitrile, two modifiers commonly used in CE-ESI-MS. Due to the speed and simplicity of the coating procedure, the polymeric surface could, if necessary, easily be regenerated. This capability is especially valuable when working with samples of complex matrix, where a capillary surface cleaning step might be desired in order to eliminate possible memory effects. The potential of PolyE-323-coated capillaries in bioanalysis using CE-ESI-MS was demonstrated by analyzing peptides and proteins up to 66 kDa using time of flight (TOF)-MS. Due to the stable, anodal electroosmotic flow generated by the coating, the use of a sheathless ESI interface was enabled, demonstrated in peptide analysis with attomole sensitivity. The fast on-line CE-ESI-TOF system using PolyE-323-coated capillaries provided efficient separation and detection of a large number of peaks in a short time, exemplified by the analysis of a tryptic digest of bovine serum albumin (BSA). The capability of the developed capillary surface coating was demonstrated by the separation of human plasma and cerebrospinal fluid (CSF).  相似文献   

17.
A two-dimensional capillary electrophoresis platform, combining isoelectric focusing (IEF) and capillary zone electrophoresis (CZE), was established on a microchip with the channel width and depth as 100 mum and 40 mum, respectively. With polyacrylamide as permanent coating, EOF in the microchannel, which could impair the separation, was decreased to 3.4x10(-9)m(2).V(-1).s(-1), about 1/10 of that obtained in the uncoated set-up. During the separation, peptides were first focused by IEF in the first dimensional channel, and then directly driven into the perpendicular channel by controlling the applied voltages, and separated by CZE. Effects of various experimental parameters, including the electric field strength, channel length, and injection frequency from the first to the second dimensional separation channel, were studied. Under optimized condition, the digests of BSA and proteins extracted from E. coli were separated, and a peak capacity of 540 was obtained, which was far greater than that obtained by each single dimensional separation. All these results showed the promise of multidimensional separation on a microchip for the high-throughput and high-resolution analysis of complex samples.  相似文献   

18.
In this study, positively charged alkylaminosilyl monomers were used to modify the inner surface of fused silica capillaries, which subsequently were employed in capillary electrophoresis (CE) and capillary electrochromatography (CEC). The obtained surfaces yield a reversed electroosmotic flow (EOF) and have varying carbon chain lengths, that interact with the analytes and give chromatographic retention. The coating procedure is very simple and fast. The performance of the modified capillaries was evaluated regarding pH influence on EOF and chromatographic interactions. The experiments were conducted with UV and mass spectrometry (MS) and applied to the separation of various neuropeptides. The derivatized surfaces showed a linear (R(2) approximately 0.99) pH dependence with isoelectric points (pI) at 8.6-8.8. Rapid separations of peptide standards and a protein digest with efficiencies as high as 5 x 10(5) plates/m were performed.  相似文献   

19.
Bioactive peptides and tryptic digests of various proteins were separated under acidic and alkaline conditions by ion-pair-reversed-phase high-performance liquid chromatography (RP-HPIPC) in 200 microm I.D. monolithic, poly(styrene-divinylbenzene)-based capillary columns using gradients of acetonitrile in 0.050% aqueous trifluoroacetic acid, pH 2.1, or 1.0% triethylamine-acetic acid, pH 10.6. Chromatographic performances with mobile phases of low and high-pH were practically equivalent and facilitated the separation of more than 50 tryptic peptides of bovine serum albumin within 15-20 min with peak widths at half height between 4 and 10 s. Neither a significant change in retentivity nor efficiency of the monolithic column was observed during 17-day operation at pH 10.6 and 50 degrees C. Upon separation by RP-HPIPC at high-pH, peptide detectabilities in full-scan negative-ion electrospray ionization mass spectrometry (negESI-MS) were about two to three times lower as compared to RP-HPIPC at low-pH with posESI-MS detection. Tandem mass spectra obtained by fragmentation of deprotonated peptide ions in negative ion mode yielded interpretable sequence information only in a few cases of relatively short peptides. However, in order to obtain sequence information for peptides separated with alkaline mobile phases, tandem mass spectrometry (MS/MS) could be performed in positive ion mode. The chromatographic selectivities were significantly different in separations performed with acidic and alkaline eluents, which facilitated the fractionation of a complex peptide mixture obtained by the tryptic digestion of 10 proteins utilizing off-line, two-dimensional RP-HPIPC at high pH x RP-HPIPC at low pH and subsequent on-line identification by posESI-MS/MS.  相似文献   

20.
Cycloaliphatic epoxy resin coating for capillary electrophoresis   总被引:3,自引:0,他引:3  
Coating the interior surface of a fused-silica capillary with a polymeric material has long been used in capillary electrophoresis (CE) to reduce or eliminate electroosmotic flow and suppress adsorption. A cycloaliphatic epoxide-based resin was bonded to silane treated capillaries and crosslinked with a curing agent. The epoxy resin coating significantly reduced electroosmotic flow over a pH range of 3-10. This coating was sufficiently hydrophilic to suppress protein adsorption. The epoxy resin coated capillary was used to separate several acidic and basic proteins and peptides. Separation efficiencies greater than 400,000 theoretical plates were achieved. The relative standard deviations in migration times for proteins were <0.8%. Speed and simplicity are important advantages of the coating procedure compared to other published coating methods.  相似文献   