首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Cat's claw is a large woody vine with hook‐like thorns, and has been traditionally used to treat inflammatory disorders in South and Central America. In this study, a rapid, validated high‐performance liquid chromatographic (HPLC) method using a silica monolithic column was developed for the simultaneous determination of oxindole alkaloids, namely rhynchophylline, pteropodine, isomitraphylline and isopteropodine, in cat's claw. The ionic liquid‐based microwave‐assisted extraction (ILMAE), considered as an environmentally friendly and powerful tool, was first applied in the extraction of oxindole alkaloids. To optimize the HPLC method, the stationary phases, pH values of mobile phase and flow rates were investigated. The validated HPLC method using a Monolithic RP18e column (100 × 4.6 mm) enables these analytes to be separated almost twice as fast as with a conventional particulate column (~16 vs ~30 min) with limits of quantification and detection of 0.5 and 0.15 μg/mL, respectively. The ILMAE conditions were optimized by the Taguchi orthogonal array design. In comparison with conventional water boiling extraction, ILMAE offers almost four times higher yields within an extremely short extraction time. The developed HPLC coupled with ILMAE method could be efficient and practical for rapid determination of oxindole alkaloids in cat's claw.  相似文献   

2.
A stationary phase (named QA C10) with quaternary ammonium embedded between a propyl and a decyl chain was synthesized by immobilization of N,N‐dimethyldecylamine on chloropropyl–silica surface. A set of representative neutral, basic, and acidic compounds was employed to evaluate its chromatographic properties. The results illustrated that QA C10 was a mixed‐mode stationary phase possessing both hydrophobic and ionic characteristics. The QA C10 stationary phase was further used for selective separation of alkaloids from Cortex phellodendri. Under acidic condition, alkaloids could be eluted in first 8 min, while other neutral and acidic fractions were retained better on QA C10 column. Then, obtained alkaloid fraction was analyzed by LC‐MS/MS and 22 alkaloids were identified. Our study confirmed the advantages and application potential of the QA C10 stationary phase for alkaloids separation.  相似文献   

3.
Via the ring‐opening reaction of epoxy groups with epinephrine, a novel epinephrine functionalized polymethacrylate monolith with fumed silica nanoparticles has been fabricated for pressurized capillary electrochromatography. The preparation of epinephrine‐modified monoliths has been optimized. In addition, morphology, electroosmotic flow, separation mechanism and column performance have been studied. The internal structure of the monolithic stationary phase was more uniform and the column efficiency increased after the incorporation of nanoparticles. With this column, satisfactory separation capability of aromatic compounds and alkaloids has been achieved and the column efficiency for naphthalene reached 138 696 plates/m. As for the real sample, 3 alkaloids were separated in Huanglian Shangqing capsules, a Chinese traditional medicine.  相似文献   

4.
In this paper, the temperature and pH stability of silica‐based RP stationary phases were investigated. Furthermore, nonsiliceous phases like a polymeric column based on polystyrene divinylbenzene and a polybutadiene coated zirconium dioxide column were also included. The columns were heated up to 150°C at dynamic conditions, which means that the eluent consisting of water and methanol (90:10, v/v) was continuously purged through the packed bed. After every 5 h, the columns were cooled down to room temperature and the efficiency was measured by injecting a test sample based on the Neue test. It could be shown that some stationary phases exhibited a very good temperature stability at the test conditions specified above.  相似文献   

5.
A porous zwitterionic monolith was prepared by in situ covalent attachment of lysine to a γ‐glycidoxypropyltrimethosysilane‐modified silica monolith. The prepared column was used to perform neutral and ionized solutes separations by pressurized (pCEC). Due to the zwitterionic nature of the resulting stationary phase, the monolithic column provided both electrostatic attraction and repulsion sites for electrochromatographic retention for ionized solutes. Separation of several nucleotides was investigated on the monolithic column. It was shown that the nucleotides could be separated based on hydrophilic and electrostatic interactions between the stationary phase and analyte. Besides, the separation property of the zwitterionic silica monolith was compared with the use of diamine‐bonded silica monolith as stationary phase. As expected, the lysine monolith exhibited a lower retention for the five nucleotides, which was due to the dissociation of the external carboxylic acid groups, leading to electrostatic repulsion with negatively charged solutes. Under the same experimental conditions, separation of the five nucleotides on the zwitterionic column was in less than 8 min, while that on the diamine column was in approximately 60 min.  相似文献   

6.
This paper describes the synthesis and chromatographic evaluation of a new polar‐embedded stationary phase, which utilized 2,4,6‐trichloro‐1,3,5‐triazine as the spacer. The resulting materials were characterized by elemental analysis, IR, and solid‐state 13C NMR. Empirical test mixtures were utilized to evaluate the column, and showed that it had good performance for basic compounds and high selectivity for polyaromatic hydrocarbons. Moreover, the novel stationary phase has unique property, especially in the separation of “homologous alkaloids” from natural products.  相似文献   

7.
A novel carboxyl‐bonded silica stationary phase was prepared by “thiol‐ene” click chemistry. The resultant Thiol‐Click‐COOH phase was evaluated under hydrophilic interaction liquid chromatography (HILIC) mobile phase conditions. A comparison of the chromatographic performance of Thiol‐Click‐COOH and pure silica columns was performed according to the retention behaviors of analytes and the charged state of the stationary phases. The results indicated that the newly developed Thiol‐Click‐COOH column has a higher surface charge and stronger hydrophilicity than the pure silica column. Furthermore, the chromatographic behaviors of five nucleosides on the Thiol‐Click‐COOH phase were investigated in detail. Finally, a good separation of 13 nucleosides and bases, and four water‐soluble vitamins was achieved.  相似文献   

8.
A novel imidazolium‐embedded iodoacetamide‐functionalized silica‐based stationary phase has been prepared by surface radical chain‐transfer polymerization. The stationary phase was characterized by Fourier transform infrared spectrometry, thermogravimetric analysis, and element analysis. Fast and efficient separations of polar analytes, such as nucleosides and nucleic acid bases, water‐soluble vitamins and saponins, were well achieved in hydrophilic interaction chromatography mode. Additionally, a mixed mode of hydrophilic interaction and reversed‐phase could be also obtained in the analysis of polar and nonpolar compounds, including weak acidic phenols, basic anilines and positional isomers, with high resolution and molecular‐planarity selectivity, outperforming the commercially available amino column. Moreover, simultaneous separation of polar and nonpolar compounds was also achieved. In conclusion, the multimodal retention capabilities of the imidazolium‐embedded iodoacetamide‐functionalized silica‐based column could offer a wide range of retention behavior and flexible selectivity toward hydrophilic and hydrophobic compounds.  相似文献   

9.
A new water‐soluble tetra‐proline‐modified calix[4]arene‐bonded silica stationary phase was prepared straightforwardly by an indirect method and characterized by elemental analysis, energy dispersive Spectrometry, solid‐state 13C NMR spectroscopy, Fourier‐transform infrared spectroscopy, and thermogravimetric analysis. Due to the simultaneous introduction of polar tetra‐proline and nonpolar calix[4]arene, the developed column possessing a double retention mode of reverse‐phase liquid chromatography and hydrophilic interaction liquid chromatography. A series of hydrophobic and hydrophilic test samples, including nucleosides and nucleotides, amines, monosubstituted benzenes, chiral compounds, and phenols, were used to evaluate the developed stationary phase. A rapid separation capability, high separation efficiency, and selectivity were achieved based on the multiple interactions between solutes and tetra‐proline‐modified calix[4]arene‐bonded silica stationary phase. Moreover, the developed stationary phase was further used to detect and separate hexamethylenetetramine in rice flour. All the results indicated the potential merits of the developed stationary phase for simultaneous separation of complex hydrophobic and hydrophilic samples with high selectivity.  相似文献   

10.
The amphiphilic polymer‐grafted silica was newly prepared as a stationary phase in high‐performance liquid chromatography. Poly(4‐vinylpyridine) with a trimethoxysilyl group at one end was grafted onto porous silica particles and the pyridyl side chains were quaternized with 1‐bromooctadecane. The obtained poly(octadecylpyridinium)‐grafted silica was characterized by elemental analysis, diffuse reflectance infrared Fourier transform spectroscopy and Brunauer–Emmett–Teller analysis. The degree of quaternization of the pyridyl groups on the obtained stationary phase was estimated to be 70%. The selective retention behaviors of polycyclic aromatic hydrocarbons including some positional isomers were investigated using poly(octadecylpyridinium)‐grafted silica as an amphiphilic polymer stationary phase in high‐performance liquid chromatography and results were compared with commercially available polymeric octadecylated silica and phenyl‐bonded silica columns. The results indicate that the selectivity toward polycyclic aromatic hydrocarbons exhibited by the amphiphilic polymer stationary phase is higher than the corresponding selectivity exhibited by a conventional phenyl‐bonded silica column. However, compared with the polymeric octadecylated silica phase, the new stationary phase presents similar retention behavior for polycyclic aromatic hydrocarbons but different retention behavior particularly for positional isomers of disubstituted benzenes as the aggregation structure of amphiphilic polymers on the surface of silica substrate has been altered during mobile phase variation.  相似文献   

11.
《Electrophoresis》2018,39(8):1086-1095
The chiral organic‐inorganic hybrid materials can exhibit a high loading, and the chiral selector nanoparticles can create efficient stationary phases for open‐tubular capillary electrochromatography (OT‐CEC). Hence, a novel protocol for the preparation of an OT column coated with nano‐amylose‐2,3‐bis(3,5‐dimethylphenylcarbamate) (nano‐ABDMPC)‐silica hybrid sol through in situ layer‐by‐layer self‐assembly method was developed for CEC enantioseparation. By controlling the assembly cycle number of nano‐ABDMPC‐silica hybrid sol, a homogeneous, dense and stable coating was successfully prepared, which was confirmed by SEM and elemental analysis. As the main parameter influencing the chiral separating effect, the nano‐ABDMPC bearing 3‐(triethoxysilyl)propyl residues concentration was investigated. The experimental results showed that 10.0 mg/mL nano‐ABDMPC bearing 3‐(triethoxysilyl)propyl residues coated OT capillary column possessed chiral recognition ability toward the six enantiomers (phenylalanine, tyrosine, tryptophan, phenethyl alcohol, 1‐phenyl‐2‐propanol, and Tröger's base) at some of the different conditions tested. Additionally, the coated OT column revealed adequate repeatability concerning run‐to‐run, day‐to‐day and column‐to‐column. These results demonstrated the promising applicability of nano‐ABDMPC‐silica hybrid sol coated OT column in CEC enantioseparations.  相似文献   

12.
A relatively new stationary phase containing a polar group embedded in a hydrophobic backbone (i.e., ACE ® C18‐amide) was evaluated for use in supercritical fluid chromatography. The amide‐based column was compared with columns packed with bare silica, C18 silica, and a terminal‐amide silica phase. The system was held at supercritical pressure and temperature with a mobile phase composition of CO2 and methanol as cosolvent. The linear solvation energy relationship model was used to evaluate the behavior of these stationary phases, relating the retention factor of selected probes to specific chromatographic interactions. A five‐component test mixture, consisting of a group of drug‐like molecules was separated isocratically. The results show that the C18‐amide stationary phase provided a combination of interactions contributing to the retention of the probe compounds. The hydrophobic interactions are favorable; however, the electron donating ability of the embedded amide group shows a large positive interaction. Under the chromatographic conditions used, the C18‐amide column was able to provide baseline resolution of all the drug‐like probe compounds in a text mixture, while the other columns tested did not.  相似文献   

13.
A dicationic imidazolium ionic liquid modified silica stationary phase was prepared and evaluated by reversed‐phase/anion‐exchange mixed‐mode chromatography. Model compounds (polycyclic aromatic hydrocarbons and anilines) were separated well on the column by reversed‐phase chromatography; inorganic anions (bromate, bromide, nitrate, iodide, and thiocyanate), and organic anions (p‐aminobenzoic acid, p‐anilinesulfonic acid, sodium benzoate, pathalic acid, and salicylic acid) were also separated individually by anion‐exchange chromatography. Based on the multiple sites of the stationary phase, the column could separate 14 solutes containing the above series of analytes in one run. The dicationic imidazolium ionic liquid modified silica can interact with hydrophobic analytes by the hydrophobic C6 chain; it can enhance selectivity to aromatic compounds by imidazolium groups; and it also provided anion‐exchange and electrostatic interactions with ionic solutes. Compared with a monocationic ionic liquid functionalized stationary phase, the new stationary phase represented enhanced selectivity owing to more interaction sites.  相似文献   

14.
A novel sulfonic‐azobenzene‐functionalized amphiphilic silica material was synthesized through the preparation of a new sulfonic azobenzene monomer and its grafting on mercaptopropyl‐modified silica by a surface‐initiated radical chain‐transfer reaction. The synthesis was confirmed by infrared spectra, elemental analysis, and thermogravimetric analysis. This new material was successfully applied as a new kind of mixed‐mode stationary phase in liquid chromatography. This allows an exceptionally flexible adjustment of retention and selectivity by tuning the experimental conditions. The distinct separation mechanisms were outlined by selected examples of chromatographic separations in the different modes. In reversed‐phase liquid chromatography, this new stationary phase presented specific chromatographic performance when evaluated using a Tanaka test mixture. Seven dinitro aromatic isomers, four steroids, and seven flavonoids were separated successfully in simple reversed‐phase mode. This stationary phase can also be used in hydrophilic interaction chromatography because of the existing polar functional groups; for this, nucleosides and their bases were used as a test mixture. Interestingly, the same nucleosides and bases can also be separated in per aqueous liquid chromatography using the same stationary phase. Three ginsenosides including Rg1, Re, and Rb1 were successfully separated in hydrophilic mode. There is the potential for more applications to benefit from this useful column.  相似文献   

15.
A novel amphiphilic silica‐based monolithic column having surface‐bound octanoyl‐aminopropyl moieties was successfully prepared by a one‐step in situ derivatization process. As expected, the amphiphilic monolithic column exhibited RP chromatographic behavior toward non‐polar solutes (e.g., alkyl benzenes) with high column performance. As the pH of the buffer inside the column increases, the EOF changed from −2.65×10−8m2 V−1s−1 at pH 3.0 to 1.20×10−8 m2 V−1s−1 at pH 8.0 with the reversion of EOF at about pH 6.4. Using acidic mobile phase, five aromatic acids can be efficiently separated in less than 6 min under co‐EOF conditions. For basic compounds, symmetrical peaks were obtained due to the existence of hydrophilic acyl amide group, which can effectively minimize the adsorption of the positively charged basic analyte to the silica‐based surface of the capillary column.  相似文献   

16.
A novel organic‐silica hybrid monolith was prepared through the binding of histidine onto the surface of monolithic matrix for mixed‐mode per aqueous and ion‐exchange capillary electrochromatography. The imidazolium and amino groups on the surface of the monolithic stationary phase were used to generate an anodic electro‐osmotic flow as well as to provide electrostatic interaction sites for the charged compounds at low pH. Typical per aqueous chromatographic behavior was observed in water‐rich mobile phases. Various polar and hydrophilic analytes were selected to evaluate the characteristics and chromatographic performance of the obtained monolith. Under per aqueous conditions, the mixed‐mode mechanism of hydrophobic and ion‐exchange interactions was observed and the resultant monolithic column proved to be very versatile for the efficient separations of these polar and hydrophilic compounds (including amides, nucleosides and nucleotide bases, benzoic acid derivatives, and amino acids) in highly aqueous mobile phases. The successful applications suggested that the histidine‐modified organic‐silica hybrid monolithic column could offer a wide range of retention behaviors and flexible selectivities toward polar and hydrophilic compounds.  相似文献   

17.
Submicron, non‐porous, chiral silica stationary phase has been prepared by the immobilization of functionalized β‐CD derivatives to isocyanate‐modified silica via chemical reaction and applied to the pressurized capillary electrochromatography (pCEC) enantio‐separation of various chiral compounds. The submicron, non‐porous, cyclodextrin‐based chiral stationary phases (sub_μm‐CSP2) exhibited excellent chiral recognition of a wide range of analytes including clenbuterol hydrochloride, mexiletine hydrochloride, chlorpheniramine maleate, esmolol hydrochloride, and metoprolol tartrate. The synthesized submicron particles were regularly spherical and uniformly non‐porous with an average diameter of around 800 nm and a mean pore size of less than 2 nm. The synthesized chiral stationary phase was packed into 10 cm × 100 μm id capillary columns. The sub_μm‐CSP2 column used in the pCEC system showed better separation of the racemates and at a higher rate compared to those used in the capillary liquid chromatography mode (cLC) system. The sub_μm‐CSP2 possessed high mechanical strength, high stereoselectivity, and long lifespan, demonstrating rapid enantio‐separation and good resolution of samples. The column provided an efficiency of up to 170 000 plates/m for n‐propylbenzene.  相似文献   

18.
Unbonded silicon oxynitride and silica high‐performance liquid chromatography stationary phases have been evaluated and compared for the separation of basic compounds of differing molecular weight, pKa, and log D using aqueous/organic mobile phases. The influences of percentage of organic modifier, buffer pH, and concentration in the mobile phase on base retention were investigated on unbonded silicon oxynitride and silica phases. The results confirmed that unbonded silicon oxynitride and silica phases demonstrated excellent separation performance for model basic compounds and both the unbonded phases examined possessed a hydrophobic/adsorption and ion‐exchange character. The silicon oxynitride stationary phase exhibited high hydrophilicity compared with silica with a reversed‐phase mobile phase. An ion‐exclusion‐type mechanism becomes predominant for the separation of three aimed bases on the silicon oxynitride column at pH 2.8. Different from silicon oxynitride stationary phase, no obvious change for the retention time of three model bases on silica stationary phase at pH 2.8 can be observed.  相似文献   

19.
Poly(l ‐lactic acid) is a linear aliphatic thermoplastic polyester that can be produced from renewable resources. A poly(l ‐lactic acid)‐modified silica stationary phase was newly prepared by amide bond reaction between amino groups on aminopropyl silica and carboxylic acid groups at the end of the poly(l ‐lactic acid) chain. The poly(l ‐lactic acid)‐silica column was characterized in reversed‐phase liquid chromatography and hydrophilic interaction liquid chromatography with the use of different mobile phase compositions. The poly(l ‐lactic acid)‐silica column was found to work in both modes, and the retention of test compounds depending on acetonitrile content exhibited “U‐shaped” curves, which was an indicator of reversed‐phase liquid chromatography/hydrophilic interaction liquid chromatography mixed‐mode retention behavior. In addition, carbonyl groups included into the poly(l ‐lactic acid) backbone work as an electron‐accepting group toward a polycyclic aromatic hydrocarbon and provide π–π interactions.  相似文献   

20.
The effectiveness of several basic compounds for testing silica‐based stationary phases was reviewed by applying them to recent columns for reversed‐phase HPLC. Most octadecylsilylated (C18) stationary phases, prepared as a base‐deactivated material from high‐purity silica gel with endcapping, provided excellent peak shape and column efficiency for the bases including benzylamine and amitriptyline that once caused problems and were subsequently employed for testing silanol activities. However, a cyclic tertiary amine, dextrometorphan, was eluted as an acceptable peak from only a few columns at neutral pH. Such a more sensitive probe is expected to contribute to further improvement of the stationary phase for reversed‐phase HPLC.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号