首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Aminosilanized magnetic carbon microspheres as a novel adsorbent were designed and fabricated. The adsorbent was used for the magnetic solid‐phase extraction of bisphenols at trace levels from environmental water samples before liquid chromatography with tandem mass spectrometry analysis. The structure, surface, and magnetic behavior of the as‐prepared aminosilanized magnetic carbon microspheres were characterized by elemental analysis, scanning electron microscopy, transmission electron microscopy, Fourier transform infrared spectroscopy, powder X‐ray diffraction, and vibrating sample magnetometry. The effects of the experimental parameters were investigated by the Plackett–Burman design, and then the parameters that were significant to the extraction efficiencies were optimized through a response surface methodology. The aminosilanized magnetic carbon microspheres exhibited high adsorption efficiency and selectivity for bisphenols. Under optimal conditions, low limits of detection (0.011–2.22 ng/L), and a wide linear range (2–3 orders of magnitude), good repeatability (4.7–7.8%, n = 5), and reproducibility (6.0–8.3%, n = 3) were achieved. The results demonstrate that the novel adsorbent possesses great potentials in the determination of trace levels of bisphenols in environmental water samples.  相似文献   

2.
Saxitoxin, which is one of the most typical paralytic shellfish poisoning toxins, ranks the highest intoxication rate of marine biological poisoning cases globally. Efficient clean‐up and extraction of saxitoxin from complex biological matrices are imperative for the analysis and concentration monitoring of the toxin when correlative poisoning cases happen. Herein, l ‐cysteine‐modified magnetic microspheres based on metal‐organic coordination were synthesized by a facile approach and applied for magnetic solid‐phase extraction of saxitoxin from rat plasma samples before liquid chromatography–tandem mass spectrometry detection. Parameters, including adsorbent amount, extraction time, desorption solution, and desorption time that could affect the extraction efficiency, were respectively investigated. The developed method demonstrated good linearity in the range of 5–300 ng/mL (R= 0.9985) with a limit of quantification of 5 ng/mL and a limit of detection of 0.5 ng/mL, acceptable accuracy. and precision of within‐run and between‐run.  相似文献   

3.
An adsorbent of carbon dot@poly(glycidyl methacrylate)@Fe3O4 nanoparticles has been developed for the microwave‐assisted magnetic solid‐phase extraction of polycyclic aromatic hydrocarbons in environmental aqueous samples prior to high‐performance liquid chromatography with UV/visible spectroscopy detection. Poly(glycidyl methacrylate) was synthesized by atom transfer radical polymerization. The chain length and amount of carbon dots attached on them can be easily controlled through changing polymerization conditions, which contributes to tunable extraction performance. The successful fabrication of the nano‐adsorbent was confirmed by transmission electronic microscopy, Fourier transform infrared spectroscopy, Raman spectroscopy and vibrating sample magnetometry. The extraction performance of the adsorbent was evaluated by using polycyclic aromatic hydrocarbons as model analytes. The key factors influencing the extraction, such as microwave power, adsorption time, desorption time and desorption solvents were investigated in detail. Under the optimal conditions, the microwave‐assisted method afforded magnetic solid‐phase extraction with short extraction time, wide dynamic linear range (0.02–200 μg/L), good linearity (R2 ≥ 98.57%) and low detection limits (20–90 ng/L) for model analytes. The adsorbent was successfully applied for analyzing polycyclic aromatic hydrocarbons in environmental aqueous samples and the recoveries were in the range of 86.0–124.2%. Thus, the proposed method is a promising candidate for fast and reliable preconcentration of trace polycyclic aromatic hydrocarbons in real water samples.  相似文献   

4.
Here in, magnetic nanoparticles combined with graphene oxide adsorbent were fabricated via a microwave‐assisted synthesis method, and used in the solid‐phase extraction of three phenolic compounds (phenol, 4‐nitrophenol, and m‐methylphenol) in environmental water samples. Various instrumental methods were employed to characterize the magnetic nanoparticles modified with graphene oxide. The influence of experimental parameters, such as desorption conditions, amount of adsorbent, extraction time, and pH, on the extraction efficiency was investigated. Owing to the high surface area and excellent adsorption capacity of the prepared material, satisfactory extraction was achieved. Under optimum conditions, a linear response was observed in the concentration range of 1.000–100.0 μg/L for phenol, 0.996–99.6 μg/L for 4‐nitrophenol, and 0.975–97.5 μg/L for m‐methylphenol, with correlation coefficients in the range of 0.9995–0.9997. The limit of detection (signal‐to‐noise ratio of 3) of the method varied between 0.5 and 0.8 μg/L. The relative standard deviations were <5.2%. The recovery percentages of the method were in the range of 89.1–104.3%. The results indicate that the graphene oxide‐modified magnetic nanoparticles possess high adsorptive abilities toward phenolic compounds in environmental water samples.  相似文献   

5.
In this study, magnetized MOF‐74 (Ni) was prepared using an ultrasound‐assisted synthesis method. This novel functional magnetic adsorbent was characterized using various techniques. Using the prepared material as adsorbents, a magnetic solid‐phase extraction method coupled with high‐performance liquid chromatography was proposed for determining four phthalate esters in Chinese liquor samples. The extraction parameters, including solution pH, adsorbent amount, extraction time, and eluent type and volume, were optimized. Under the optimized conditions, proposed method showed good linearity within the range of 1.53–200 μg/L for diphenyl phthalate, 2.03–200 μg/L for butyl benzyl phthalate, 7.02–200 μg/L for diamyl phthalate, and 6.03–200 μg/L for dicyclohexyl phthalate, with correlation coefficients > 0.9944, low limits of detection (0.46–2.10 μg/L, S/N = 3), and good extraction repeatability (relative standard deviations of 3.7%, n = 6). This method was successfully used to analyze phthalate esters in Chinese liquor samples with recoveries of 74.4–104.8%. Two phthalate esters were detected in two samples, both at concentrations that satisfied the Chinese national standard, indicating this method has practical application prospects. The extraction efficiency of this method was also compared with conventional solid‐phase extraction using commercial C18 cartridges. The results demonstrated that the proposed magnetic solid‐phase extraction is a simple, time‐saving, efficient, and low‐cost method.  相似文献   

6.
A new method named graphene‐coated magnetic‐sheet solid‐phase extraction based on a magnetic three‐dimensional graphene sorbent was developed for the extraction of aflatoxins prior to high‐performance liquid chromatography with fluorescence detection. The use of a perforated magnetic‐sheet for fixing the magnetic nanoparticles is a new feature of the method. Hence, the adsorbent particles can be separated from sample solution without using an external magnetic field. This made the procedure very simple and easy to operate so that all steps of the extraction process (sample loading, washing, and desorption) were carried out continuously using two lab‐made syringe pumps. The factors affecting the performance of extraction procedure such as the extraction solvent, adsorbent dose, sample loading flow rate, ionic strength, pH, and desorption parameters were investigated and optimized. Under the optimal conditions, the obtained enrichment factors and limits of detection were in the range of 205–236 and 0.09–0.15 μg/kg, respectively. The relative standard deviations were <3.4 and 7.5% for the intraday (= 6) and interday (= 4) precisions, respectively. The developed method was successfully applied to determine aflatoxins B1, B2, G1, and G2 in different soy‐based food samples.  相似文献   

7.
A magnetic solid‐phase extraction adsorbent that consisted of citrus peel‐derived nanoporous carbon and silica‐coated Fe3O4 microspheres (C/SiO2@Fe3O4) was successfully fabricated by co‐precipitation. As a modifier for magnetic microspheres, citrus peel‐derived nanoporous carbon was not only economical and renewable for its raw material, but exerted enormous nanosized pore structure, which could directly influence the type of adsorbed analytes. The C/SiO2@Fe3O4 also possessed the advantages of Fe3O4 microspheres like superparamagnetism, which could be easily separated magnetically after adsorption. Integrating the superior of biomass‐derived nanoporous carbon and Fe3O4 microspheres, the as‐prepared C/SiO2@Fe3O4 showed high extraction efficiency for target analytes. The obtained material was characterized by scanning electron microscopy, Fourier transform infrared spectroscopy, X‐ray photoelectron spectroscopy, and the Brunauer–Emmett–Teller method, which demonstrated that C/SiO2@Fe3O4 was successfully synthesized. Under the optimal conditions, the adsorbent was selected for the selective adsorption of seven insecticides before gas chromatography with mass spectrometry detection, and good linearity was obtained in the concentration range of 2–200 μg/kg with the correlation coefficient ranging from 0.9952 to 0.9997. The limits of detection were in the range of 0.03–0.39 μg/kg. The proposed method has been successfully applied to the enrichment and detection of seven insecticides in real vegetable samples.  相似文献   

8.
A novel adsorbent made of polydopamine‐functionalized magnetic graphene and carbon nanotubes hybrid nanocomposite was synthesized and applied to determine 16 priority polycyclic aromatic hydrocarbons by magnetic solid phase extraction in water samples. FTIR spectroscopy, transmission electron microscopy, scanning electron microscopy, and Raman spectroscopy consistently indicate that the synthesized adsorbents are made of core–shell nanoparticles well dispersed on the surface of graphene and carbon nanotubes. The major factors affecting the extraction efficiency, including the pH value of samples, the amount of adsorbent, adsorption time and desorption time, type and volume of desorption solvent, were systematically optimized. Under the optimum extraction conditions, a linear response was obtained for polycyclic aromatic hydrocarbons between concentrations of 10 and 500 ng/L with the correlation coefficients ranging from 0.9958 to 0.9989, and the limits of detection (S/N = 3) were between 0.1 and 3.0 ng/L. Satisfactory results were also obtained when applying these magnetic graphene/carbon nanotubes/polydopamine hybrid nanocomposites to detect polycyclic aromatic hydrocarbons in several environmental aqueous samples.  相似文献   

9.
The dummy molecularly imprinted polymers were prepared by Pickering emulsion polymerization. 4,4′‐(1‐Phenylethylidene) bisphenol was selected as the dummy template to avoid the leakage of the target bisphenols. The microsphere particles were characterized by scanning electron microscopy and nitrogen adsorption–desorption measurements, demonstrating that the regular‐shaped and medium‐sized particles (40–70 μm) were obtained with a specific surface area of 355.759 m2/g and a total pore volume of 0.561 cm3/g. The molecular imprinting properties of the particles were evaluated by static adsorption and chromatographic evaluation experiments. The association constant and maximum adsorption amount of bisphenol A were 0.115 mmol/L and 3.327 μmol/g using Scatchard analysis. The microsphere particles were then used as a solid‐phase extraction sorbent for selective extraction of seven bisphenols. The method of dummy molecularly imprinted solid‐phase extraction coupled with high‐performance liquid chromatography and diode array detection was successfully established for the extraction and determination of seven bisphenols from environmental sediment samples with method detection limits of 0.6–1.1 ng/g. Good recoveries (75.5–105.2%) for sediment samples at two spiking levels (500 and 250 ng/g) and reproducibility (RSDs < 7.7%, n = 3) were obtained.  相似文献   

10.
In this work, a simple, facile, and sensitive magnetic solid‐phase extraction method was developed for the extraction and enrichment of three representative steroid hormones before high‐performance liquid chromatography analysis. Gold‐modified Fe3O4 nanoparticles, as novel magnetic adsorbents, were prepared by a rapid and environmentally friendly procedure in which polydopamine served as the reductant as well as the stabilizer for the gold nanoparticles, thus successfully avoiding the use of some toxic reagents. To obtain maximum extraction efficiency, several significant factors affecting the preconcentration steps, including the amount of adsorbent, extraction time, pH of the sample solution, and the desorption conditions, were optimized, and the enrichment factors for three steroids were all higher than 90. The validity of the established method was evaluated and good analytical characteristics were obtained. A wide linearity range (0.8–500 μg/L for all the analytes) was attained with good correlation (R2 ≥ 0.991). The low limits of detection were 0.20–0.25 μg/L, and the relative standard deviations ranged from 0.83 to 4.63%, demonstrating a good precision. The proposed method was also successfully applied to the extraction and analysis of steroids in urine, milk, and water samples with satisfactory results, which showed its reliability and feasibility in real sample analysis.  相似文献   

11.
Core–shell magnetic carbon microspheres were synthesized by a simple hydrothermal method and used as a novel magnetic solid‐phase extraction adsorbent for the sensitive determination of polybrominated diphenyl ethers in environmental water samples. Gas chromatography with negative chemical ionization mass spectrometry was adopted for the detection. Box–Behnken design was used to investigate and optimize important magnetic solid‐phase extraction parameters through response surface methodology. Under the optimal conditions, low limits of detection (0.07–0.17 ng·L?1), a wide linear range (1–1000 ng·L?1), and good repeatability (0.80–4.58%) were achieved. The developed method was validated with several real water samples, and satisfactory results were obtained in the range of 72.8–97.9%. These results indicated that core–shell magnetic carbon microspheres have great potential as an adsorbent for the magnetic solid‐phase extraction of polybrominated diphenyl ethers at trace levels from environmental water samples.  相似文献   

12.
A new facile, rapid, inexpensive, and sensitive method for the analysis of six trace trichlorophenols in seawater samples was developed by magnetic micro‐solid‐phase extraction coupled to liquid chromatography with tandem mass spectrometry. Core–shell covalently functionalized ferroferric oxide coated with aminated silicon dioxide and decorated with multiwalled carbon nanotubes was applied as an adsorbent to perform the extraction process. The effect of factors including solution pH, contact time, adsorbent amount, and ionic strength were investigated in detail. The obtained results revealed that the proposed adsorbent was a highly effective and low‐cost magnetic micro‐solid‐phase extraction material for the enrichment of 2,3,4‐trichlorophenol, 2,3,5‐trichlorophenol, 2,3,6‐trichlorophenol, 2,4,5‐trichlorophenol, 2,4,6‐trichlorophenol, and 3,4,5‐trichlorophenol from seawater. Under the optimized conditions, the recoveries ranged from 88.0 to 99.5% at the three spiking levels, the limits of detection and the limits of quantification were 0.002 and 0.007 μg/L for the six trichlorophenols, respectively. The intra‐ and interday relative standard deviations were 2.0–6.7 and 4.5–8.9%, respectively. The calibration curves showed a good linearity in the range of 0.02–5.0 μg/L. The routine run analyses showed that the developed method was fast, simple, accurate, solvent‐saving and high resolution, and it was suitable for the determination of trace trichlorophenols in seawater.  相似文献   

13.
A new type of adsorbent composed of magnetic three‐dimensional graphene coated with silver nanoparticles was synthesized by an electroless technique and used in the magnetic solid‐phase extraction of selected pesticides (fenitrothion, chlorpyrifos, and hexaconazole) before gas chromatography with a micro‐electron capture detector. The adsorbent was characterized using Fourier‐transform infrared spectroscopy, X‐ray diffraction, vibrating sample magnetometry, and field‐emission scanning electron microscopy. The important extraction parameters such as pH, adsorbent dose, extraction time, and desorption conditions were investigated. Under the optimal conditions, the analytical figures of merit were obtained as: linear dynamic range of 0.1–5 ng/g with determination coefficients of 0.991–0.996; limit of detection of 0.07–0.13 ng/g; limit of quantification of 0.242–0.448 ng/g; and the intraday and interday relative standard deviations (= 5 ng/g, = 3) were 3.8–8.7 and 6.6–8.9%, respectively. The developed method was successfully applied for analysis of the selected pesticides in tomato and grape with extraction recoveries in the range of 72.8–109.6%.  相似文献   

14.
A novel magnetic adsorbent Fe3O4/reduced graphene oxide‐carbon nanotubes, was prepared by one‐pot solvothermal synthesis method. It was characterized by scanning electron microscopy, X‐ray powder diffraction and vibrating sample magnetometry. The diameter of Fe3O4 microparticles was about 350 nm, which were covered by carbon nanotubes and reduced graphene oxide sheets, while carbon nanotubes inserted between the reduced graphene oxide sheets effectively prevented their aggregation. The composite had large surface area and good magnetic property, suiting for magnetic solid‐phase extraction and the determination of sulfonamides, by coupling with high‐performance liquid chromatography. Under the optimized conditions (including extraction time, amount of adsorbent, solution pH, ionic strength and desorption conditions), a good linear was achieved in the concentration range of 5–500 μg/L and the low limits of detection and low limits of quantification were 0.35–1.32 and 1.16–4.40 μg/L, respectively. The enrichment factors were estimated to be 24.72 to 30.15 fold. The proposed method was applied for the detection of sulfonamides in milk sample and the recoveries were 88.4–105.9%, with relative standard deviations of 0.74–5.38%.  相似文献   

15.
We present a simple method for the fabrication of a magnetic amino‐functionalized zinc metal‐organic framework based on a magnetic graphene oxide composite. The resultant framework exhibited a porous 3D structure, high surface area and good adsorption properties for nitrogen‐containing heterocyclic fungicides. The adsorption process and capacity indicated that the primary adsorption mechanism might be hydrogen bonding and π‐π conjugation. In addition, an optimized protocol for magnetic solid phase extraction was developed (such as adsorbent content, pH, and desorption solvent), and utilized for the extraction of nitrogen‐containing heterocyclic fungicides from vegetable samples. Quantitation by high performance liquid chromatography coupled with tandem mass spectrometry offered a detection limit of 0.21–1.0 μg/L (S/N = 3) with correlation coefficients larger than 0.9975. These results demonstrate that magnetic amino‐functionalized zinc metal‐organic framewor is a promising adsorbent for the extraction and quantitation of nitrogen‐containing heterocyclic fungicides.  相似文献   

16.
The simultaneous determination of amphetamine and methadone was carried out by magnetic graphene oxide nanoparticles, a magnetic solid‐phase extraction adsorbent, as a new sample treatment technique. The main factors (the amounts of sample volume, amount of adsorbent, type and amount of extraction organic solvent, time of extraction and desorption, pH, the ionic strength of extraction medium, and agitation rate) influencing the extraction efficiency were investigated and optimized. Under the optimized conditions, good linearity was observed in the range of 100–1500 ng/mL for amphetamine and 100–1000 ng/mL for methadone. The method was evaluated for determination of AM and methadone in positive urine samples, satisfactory results were obtained, therefore magnetic solid‐phase extraction can be applied as a novel method for the determination of drugs of abuse in forensic laboratories.  相似文献   

17.
In this work, core‐shell structured magnetic mesoporous carbon nanospheres were fabricated from the carbonization of metal‐polyphenol coordination polymer‐coated Fe3O4 nanoparticles. The preparation method is simple, fast, versatile, and easy to scale up. Magnetic mesoporous carbon nanospheres exhibit a high specific surface area, high superparamagnetism, and high adsorption efficiencies for phthalates. Four phthalates were extracted from aqueous solutions by using magnetic mesoporous carbon nanospheres via magnetic solid phase extraction. Subsequent analysis was performed by using high‐performance liquid chromatography with ultraviolet detection. The analytical method has good linearity in the concentration range of 1–200 ng/mL for diethyl phthalate, diisobutyl phthalate, and dicyclohexyl phthalate, and 3–200 ng/mL for dipropyl phthalate. The limits of detection were in the range of 0.10–0.62 ng/mL. Compared with previous methods, this method has a lower detection limit, wider linearity range, and faster adsorption and desorption rates. The results indicate that magnetic mesoporous carbon nanospheres are suitable for the enrichment of hydrophobic substances from aqueous solutions.  相似文献   

18.
Core–shell metal–organic framework materials have attracted considerable attention mainly due to their enhanced or new physicochemical properties compared with their single‐component counterparts. In this work, a core–shell heterostructure of CoFe2O4‐Zeolitic Imidazolate Framework‐8 (ZIF‐8@CoFe2O4) is successfully fabricated and used as an solid‐phase extraction adsorbent to efficiently extract Congo Red and Basic Red 2 dyes from contaminated aqueous solution. Vibrating sample magnetometry indicates that the saturated magnetization of ZIF‐8@CoFe2O4 is 3.3 emu/g, which is large enough for magnetic separation. The obtained hybrid magnetic metal‐organic framework based material ZIF‐8@CoFe2O4 can remove the investigated dyes very fast within 1 min of the contact time. The adsorbent ZIF‐8@CoFe2O4 also shows a good reusability. After regeneration, the adsorbent can still exhibit high removal efficiency (~97%) toward Congo Red for five cycles of desorption–adsorption. This work reveals the great potential of core–shell ZIF‐8@CoFe2O4 sorbents for the fast separation and preconcentration of organic pollutants in aqueous solution before high‐performance liquid chromatography analysis.  相似文献   

19.
A facile and highly efficient magnetic solid‐phase extraction method has been developed for Z‐ligustilide, the major therapeutic agent in Angelica sinensis. The solid‐phase adsorbent material used was prepared by conjugating carbon nanotubes with magnetic Fe3O4 nanoparticles via a hydrothermal reaction. The magnetic material showed a high affinity toward Z‐ligustilide due to the π–π stacking interaction between the carbon nanotubes and Z‐ligustilide, allowing a quick and selective exaction of Z‐ligustilide from complex sample matrices. Factors influencing the magnetic solid‐phase extraction such as the amount of the added adsorbent, adsorption and desorption time, and desorption solvent, were investigated. Due to its high extraction efficiency, this method was proved highly useful for sample cleanup/enrichment in quantitative high‐performance liquid chromatography analysis. The proposed method had a linear calibration curve (R2 = 0.9983) over the concentration between 4 ng/mL and 200 μg/mL Z‐ligustilide. The accuracy of the method was determined by the recovery, which was from 92.07 to 104.02%, with the relative standard deviations >4.51%.  相似文献   

20.
A new, rapid, green, and cost‐effective magnetic solid‐phase extraction of ochratoxin A from red wine samples was developed using polydopamine‐coated magnetic multi‐walled carbon nanotubes as the absorbent. The polydopamine‐coated magnetic multi‐walled carbon nanotubes were fabricated with magnetic multi‐walled carbon nanotubes and dopamine by an in situ oxidative self‐polymerization approach. Transmission electron microscopy, dynamic light scattering, X‐ray photoelectron spectroscopy and vibrating sample magnetometry were used to characterize the absorbents. Ochratoxin A was quantified with high‐performance liquid chromatography coupled with fluorescence detection, with excitation and emission wavelengths of 338 and 455 nm, respectively. The conditions affecting the magnetic solid‐phase extraction procedure, such as pH, extraction solution, extraction time, absorbent amount, desorption solution and desorption time were investigated to obtain the optimal extraction conditions. Under the optimized conditions, the extraction recovery was 91.8–104.5% for ochratoxin A. A linear calibration curve was obtained in the range of 0.1–2.0 ng/mL. The limit of detection was 0.07 ng/mL, and the limit of quantitation was 0.21 ng/mL. The recoveries of ochratoxin A for spiked red wine sample ranged from 95.65 to 100.65% with relative standard deviation less than 8%. The polydopamine‐coated magnetic multi‐walled carbon nanotubes showed a high affinity toward ochratoxin A, allowing selective extraction and quantification of ochratoxin A from complex sample matrixes.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号