首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The aim of this study was to investigate the genetic polymorphism of 20 short tandem repeat (STR) loci including D1S1656, D2S1338, D3S1358, D5S818, D6S1043, D7S820, D8S1179, D12S391, D13S317, D16S539, D18S51, D19S433, D21S11, CSF1PO, FGA, Penta D, Penta E, TH01, TPOX, and vWA in Han population of Henan, China and to assess its value in forensic science. Genomic DNA was extracted from 274 blood samples of unrelated healthy individuals in the Henan Han population. Alleles were amplified with PowerPlex® 21 system kit and PCR products were detected with ABI3130 genetic analyzer (Applied Biosystems) and the data were analyzed with modified PowerStats v1.2. A total of 229 alleles were observed in this Han population and the allelic frequencies ranged from 0.0020 to 0.5090 in the present study. Observed genotype distributions for each locus do not show deviations from Hardy–Weinberg equilibrium expectations (p < 0.05). The combined power of discrimination, combined power of exclusion, and combined matching probability of this 20 STR loci were 0.999999999, 0.999999994603, and 4.0433 × 10?24, respectively. The 20 STR loci are highly polymorphic in the Han population of Henan, China and they may be of great value in forensic science and human population genetics.  相似文献   

2.
Massively parallel sequencing of forensic STRs simultaneously provides length-based genotypes and core repeat sequences as well as flanking sequence variations. Here, we report primer sequences and concentrations of a next-generation sequencing (NGS)-based in-house panel covering 28 autosomal STR loci (CSF1PO, D1GATA113, D1S1627, D1S1656, D1S1677, D2S441, D2S1776, D3S3053, D5S818, D6S474, D6S1017, D6S1043, D8S1179, D9S2157, D10S1435, D11S4463, D13S317, D14S1434, D16S539, D18S51, D18S853, D20S482, D20S1082, D22S1045, FGA, TH01, TPOX, and vWA) and the sex determinant locus Amelogenin. Preliminary evaluation experiments showed that the panel yielded intralocus- and interlocus-balanced sequencing data with a sensitivity as low as 62.5 pg input DNA. A total of 203 individuals from Yunnan Bai population were sequenced with this panel. Comparative forensic genetic analyses showed that sequence-based matching probability of this 29-plex panel reached 2.37 × 10−29, which was 23 times lower than the length-based data. Compound stutter sequences of eight STRs were compared with parental alleles. For seven loci, repeat motif insertions or deletions occurred in the longest uninterrupted repeat sequences (LUS). However, LUS and non-LUS stutters co-existed in the locus D6S474 with different sequencing depth ratios. These results supplemented our current knowledge of forensic STR stutters, and provided a sound basis for DNA mixture deconvolution.  相似文献   

3.
Previous studies have demonstrated that a large sample size is needed to reliably estimate population‐ and locus‐specific microsatellite mutation rates. Therefore, we conducted a long‐term collaboration study and performed a comprehensive analysis on the mutation characteristics of 19 autosomal short tandem repeat (STR) loci. The STR loci located on 15 of 22 autosomal chromosomes were analyzed in a total of 21 106 samples (11 468 parent–child meioses) in a Chinese population. This provided 217 892 allele transfers at 19 STR loci. An overall mutation rate of 1.20 × 10?3 (95% CI, 1.06–1.36 × 10?3) was observed in the populations across 18 of 19 STR loci, except for the TH01 locus with no mutation found. Most STR mutations (97.7%) were single‐step mutations, and only a few mutations (2.30%) comprised two and multiple steps. Interestingly, approximately 93% of mutation events occur in the male germline. The mutation ratios increased with the paternal age at child birth (r = 0.99, p<0.05), but not maternal age. Last, with the combination analysis of the data from the southern Chinese population, we drew a picture of 19 STR mutations in China. In conclusion, the data from this study will provide useful information in parentage testing, kinship analysis, and population genetics.  相似文献   

4.
Shi Y 《Electrophoresis》2006,27(19):3703-3711
The ability of plastic microfluidic devices with separation channel lengths of 6, 10 or 18 cm to perform high-quality and high-performance ssDNA analysis was evaluated. Specifically, four-color DNA sequencing separation of a terminator sequencing standard using replaceable, urea-denaturing linear polyacrylamide (LPA) solution as a sieving matrix, yielded read lengths of 410 bases in 15 min with base calling accuracy of 99.2% on a 6-cm device, and 640 bases in 35 min with accuracy of 98.0% on a 18-cm device. A two-color sizing analysis of four-locus (CSF1PO, TPOX, TH01, vWA) short tandem repeats (STRs) allelic ladder on a 10-cm device indicated a mean SD of +/- 0.08 base pairs (bp) between runs, and single bp resolution of spiked TH01 allele 9.3 (198 bp) from TH01 allele 10 (199 bp) of the CTTv ladder with R = 0.81. A four-color multiplex sizing analysis of three different AmpFlSTR allelic ladders consisting of nine loci (D3S1358, vWA, FGA, D8S1179, D21S11, D18S51, D5S818, D13S317, D7S820) and gender alleles (Amelogenin) on a 10-cm device had a mean SD of +/- 0.15 bp between runs for sizing three loci, i.e., FGA, D18S51 and D3S818; alleles differing by 2 bp in size were resolved with resolutions close to baseline. This work demonstrates that plastic microfluidic devices are capable of quality sequencing and STR sizing comparable to that of glass devices of similar separation lengths.  相似文献   

5.
The Microreader? 20A ID system is designed for forensic applications such as personal identification, parentage testing, and research. It includes 13 combined DNA index system (CODIS) short tandem repeat (STR) loci (CSF1PO, FGA, TH01, TPOX, vWA, D3S1358, D5S818, D7S820, D8S1179, D13S317, D16S539, D18S51, and D21S11), three expanded CODIS STR loci (D12S391, D19S433, and D2S1338), three non‐CODIS STR loci (D6S1043, Penta D, and Penta E), and the amelogenin locus in one reaction with a six‐dye fluorescent (FAM, HEX, TAMAR, ROX, PUR, and QD550) analysis system. In this study, the Microreader? 20A ID system was validated according to the Scientific Working Group on DNA Analysis Methods validation guidelines for forensic DNA Analysis methods and Chinese national standard, including PCR‐based studies, sensitivity study, precision, and accuracy evaluation, stutter calculation, inhibitor tests, species specificity, and DNA mixture studies. Our results suggest that the Microreader? 20A ID system is a useful tool for personal identification and parentage testing.  相似文献   

6.
Human identification and paternity testing are usually based on the study of STRs depending on their particular characteristics in the forensic investigation. In this paper, we developed a sensitive genotyping system, SiFaSTR? 23‐plex, which is able to characterize 18 expanded Combined DNA Index System STRs (D3S1358, D5S818, D2S1338, TPOX, CSF1PO, TH01, vWA, D7S820, D21S11, D10S1248, D8S1179, D1S1656, D18S51, D12S391, D19S433, D16S539, D13S317, and FGA), three highly polymorphic STRs among Chinese people (Penta D, Penta E, and D6S1043), one Y‐chromosome Indel and amelogenin using a multiplex PCR; the PCR amplified products were analyzed using the Applied Biosystems 3500 Genetic Analyzer. Full genotyping profiles were obtained using only 31.25 pg of control DNA; various case‐type specimens, as well as ten‐year‐old samples were also successfully genotyped. Additionally, in the validation studies, this multiplex was demonstrated to be human‐specific and compatible with the interference of multiple PCR inhibitors. The system also enabled the detection of mixtures, and complete profiles could be obtained at the mixed ratios of 1:1, 1:3, and 3:1. The development and validation study here illustrated that the SiFaSTR? 23‐plex system is accurate, powerful, and more sensitive than many other systems. What's more, the population data in our study not only illustrated that this 23‐plex typing system was straightforward and efficient but also expanded the Chinese STR database, which could facilitate the appropriate application of the 23 genetic markers in forensic genetics, especially in the Chinese population.  相似文献   

7.
Recombination fractions between forensic STRs can be extrapolated from the International HapMap Project, but the concordance between recombination fractions predicated from genetic maps and derived from observation of STR transmissions in families is still ambiguous for autosomal STRs because of limited family studies. Therefore, the main goal of this study is to compare recombination fractions estimated by pedigree analysis with those derived from HapMap phase SNP data. Genotypes of nine autosomal STR pairs (TPOX‐D2S1772, D5S818‐CSF1PO, D7S3048‐D7S820, D8S1132‐D8S1179, TH01‐D11S2368, vWA‐D12S391, D13S325‐D13S317, D18S51‐D18S1364, and D21S11‐PentaD) from 207 two‐generation families with two to five children (the number of families with five, four, three, and two children was 2, 3, 20, and 182, respectively) were used to analyze the recombination. The linkage analysis showed that significant linkage was observed at six STR pairs (D5S818‐CSF1PO, D8S1132‐D8S1179, TH01‐D11S2368, vWA‐D12S391, D13S325‐D13S317, and D18S51‐D18S1364) with genetic distances <36.22 cM in HapMap. Their recombination fractions calculated from family data were very close to those derived from HapMap. However, three STR pairs of TPOX‐D2S1772, D7S3048‐D7S820, and D21S11‐PentaD showed no significant linkage with genetic distances from 43.38 to 91.49 cM. Our results indicate that recombination fractions extrapolated from HapMap can provide a substitute if empirical data are unavailable for the linkage STR pair with a genetic distance spanned <36.22 cM.  相似文献   

8.
This paper describes the development and validation of a novel 31-locus, six-dye STR multiplex system, which is designed to meet the needs of the rapidly growing Chinese forensic database. This new assay combines 20 extended-CODIS core loci (D3S1358, D5S818, TPOX, CSF1PO, TH01, vWA, D7S820, D21S11, D8S1179, D18S51, D16S539, D13S317, FGA, D1S1656, D2S441, D2S1338, D10S1248, D12S391, D19S433, and D22S1045), nine highly polymorphic loci in Chinese Han population (D3S3045, D6S1043, D6S477, D8S1132, D10S1435, D15S659, D19S253, Penta D, and Penta E), and two gender determining markers, amelogenin and Y-Indel, which could amplify DNA from extracts, as well as direct amplification from substrates. To demonstrate the suitability for forensic applications, this system was validated by precision and accuracy evaluation, concordance tests, case sample tests, sensitivity, species specificity, stability, stutter calculation, and DNA mixtures, according to the guidelines described by the Scientific Working Group on DNA Analysis Methods (SWGDAM) and regulations published by the China Ministry of Public Security. The validation results indicate the robustness and reliability of this new system, and it could be a potentially helpful tool for human identification and paternity testing in the Chinese population, as well as facilitating global forensic DNA data sharing.  相似文献   

9.
We used an infrared (IR) automated fluorescence monolaser sequencer for the analysis of 13 autosomal short tandem repeat (STR) systems (TPOX, D3S1358, FGA, CSF1PO, D5S818, D7S820, D8S1179, TH01, vWA, D13S317, D16S359, D18S51, D21S11) and the X-Y homologous gene amelogenin system. These two systems represent the core of the combined DNA index systems (CODIS). Four independent multiplex reactions, based on the polymerase chain reaction (PCR) technique and on the direct labeling of the forward primer of every primer pair, with a new molecule (IRDye800), were set up, permitting the exact characterization of the alleles by comparison with ladders of specific sequenced alleles. This is the first report of the whole analysis of the STRs of the CODIS core using an IR automated DNA sequencer. The protocol was used to solve paternity/maternity tests and for population studies. The electrophoretic system also proved useful for the correct typing of those loci differing in size by only 2 bp. A sensibility study demonstrated that the test can detect an average of 10 pg of undegraded human DNA. We also performed a preliminary study analyzing some forensic samples and mixed stains, which suggested the usefulness of using this analytical system for human identification as well as for forensic purposes.  相似文献   

10.
We used the variable number tandem repeat (VNTR) polymorphism and the ten short tandem repeat (STR) polymorphisms to study a number of disputed paternity cases in the Japanese population. For the determination of VNTR locus (D1S80) and the ten STR loci (vWA, F13B, TH01, TPOX, CSF1PO, F13A01, LPL, D3S1744, D12S1090, D18S849) we used polymerase chain reaction (PCR) amplification and the vertical polyacrylamide gel electrophoresis technique followed by SYBR green I staining. The irregular repeats were analyzed by sequencing from bands of vertical polyacrylamide gel electrophoresis using the latest gene analyzing equipment, the ABI PRISM 310 Genetic Analyzer. The probable genotypes of the deceased putative father were deduced by Komatu's method from the genotypes of the widow and the genotypes of their children. The calculation of paternity probability used the Essen-Moller formula and Bayes's theorem. Calculated in eleven loci, the distinguishing probabilities (DP) and the mean exclusion chance (MEC) were 0.9999 and 0.9989, respectively. Therefore, information obtained from eleven DNA polymorphisms is enough to determine paternity plausibility.  相似文献   

11.
The Microreader 28A ID System is a new 28-plex genotyping system with 6-dye multiplex amplification, which allows the simultaneous amplification of all 20 Combined DNA Index System (CODIS) core loci (CSF1PO, D3S1358, D5S818, D7S820, D8S1179, D13S317, D16S539, D18S51, D21S11, FGA, TH01, TPOX, vWA, D1S1656, D2S441, D2S1338, D10S1248, D12S391, D19S433, D22S1045), plus five extended STRs loci (D6S1043, Penta D, Penta E, DYS391, SE33), 2 Y-Indels (Rs2032678, Rs771783753), and the amelogenin loci. This system can be used for forensic analyses, such as personal identification, kinship testing, scientific research, database applications, and other aspects of human genetic identification. The validation of the Microreader 28A ID System followed the “Validation Guidelines for DNA Analysis Methods (2016)” described by the Scientific Working Group on DNA Analysis Methods and the regulations published by the China Ministry of Public Security. Our tests included PCR-based studies, sensitivity study, precision and accuracy evaluation, stutter percentage and heterozygous peak height ratio, inhibitor tests, species specificity, and population studies. The validation results suggest that the Microreader 28A ID system is a robust and reliable amplification kit for personal identification, kinship testing, and forensic database applications.  相似文献   

12.
The goal of the study was to develop a STR multiplex ("Paterniplex") that is--as supplement to commercially available multiplex kits like the Identifiler kit (Applied Biosystems, Foster City, CA)--suitable for solving complex paternity cases such as deficiency cases or cases with mutations. The Paterniplex comprises the nine highly polymorphic STRs D8S1132, D7S1517, D10S2325, D12S391, Se33, D17S976, Penta E, Penta D and FGA in addition to Amelogenin as sex determination marker. The loci were selected because of their high degree of polymorphism (higher than that of the widely used TH01 marker). Only one locus, FGA, is shared with the Identifiler kit to avoid sample mix up. The study further gives details on the population genetics of the loci in a German Caucasian population (allelic distribution, Hardy-Weinberg Equilibrium and forensic efficiency markers such as the Discriminating Power) and three examples for cases that could not be solved using commercially available kits alone, but using the Paterniplex in addition to a commercial kit.  相似文献   

13.
We have developed a novel STR 25‐plex florescence multiplex‐STR kit (DNATyper25) to genotype 23 autosomal and two sex‐linked loci for forensic applications and paternity analysis. Of the 23 autosomal loci, 20 are non‐CODIS. The sex‐linked markers include a Y‐STR locus (DYS391) and the Amelogenin gene. We present developmental validation studies to show that the DNATyper25 kit is reproducible, accurate, sensitive, and robust. Sensitivity testing showed that full profiles were achieved with as low as 125 pg of human DNA. Specificity testing demonstrated a lack of cross reactivity with a variety of commonly encountered non‐human DNA contaminants. Stability testing showed that full profiles were obtained with humic acid concentration ≤60 ng/μL and hematin concentration <400 μM. For forensic evaluation, the 23 autosomal STRs followed the Hardy–Weinberg equilibrium. In an analysis of 509 Chinese (CN) Hans, we detected a combined total of 181 alleles at the 23 autosomal STR loci. Since these autosomal STRs are independent from one another, PM was 8.4528 × 10?22, TDP was 0.999 999 999 999 999 999 999, CEP was 0.999 999 8395. The forensic efficiency parameters demonstrated that these autosomal STRs are highly polymorphic and informative in the Han population of China. We performed population comparisons and showed that the Northern CN Han has a close genetic relationship with the Luzhou Han, Tujia, and Bai populations. We propose that the DNATyper25 kit will be useful for cases where paternity analysis is difficult and for situations where DNA samples are limited in quantity and low in quality.  相似文献   

14.
In this work, the electro-catalytic oxidation of phenol was studied using the aluminum oxide supported onto activated carbon (Al2O3/AC). The later was successfully prepared by impregnating aluminum particles in the activated carbon (AC) using heat treatment. Al2O3/AC was characterized by X-ray diffraction (XRD) and infrared spectroscopy (IR). The electro-catalytic performance of the Al2O3/AC for phenol oxidation was studied using cyclic voltammetry (CV), chronoamperometry, linear sweep voltammetry polarization, electrochemical impedance spectroscopy and differential pulse voltammetry (DPV) in 0.1 mol L?1 Na2SO4. It has been shown that the proposed catalyst exhibits remarkably an electro-catalytic performance toward phenol oxidation. Moreover, the oxidation peak currents are linearly dependent on the concentration of phenol in the wide ranges from 1.0 × 10?3 mol L?1 to 1.0 × 10?4 mol L?1 and 8.0 × 10?5 mol L?1 to 1.0 × 10?6 mol L?1 with a detection limit of 1.51 × 10?7 mol L?1 (signal (S) to noise (N) ratio, S/N = 3) and response time of 3 min. The possible interferences were evaluated in 1.0 × 10?5 mol L?1 of phenol. The proposed catalyst also indicated suitable repeatability and stability. Moreover, the proposed Al2O3/AC–CPE has been successfully applied for the phenol analysis in natural waters and olive oil samples with good recoveries.  相似文献   

15.
The aim of this study was to investigate a 13 non‐CODIS STR loci database using three national populations from China. A new multiplex PCR system that simultaneously amplified 13 loci in the same PCR reaction was developed. This multiplex system included the 13 STR markers (D3S2402, D3S2452, D3S1766, D3S4554, D3S2388, D3S3051, D3S3053, D4S2364, D4S2404, AC001348A, AC001348B, D17S975, and D17S1294), which were successfully analyzed by using 441 DNA samples from three national populations in China (154 Mongol, 177 Kazakh, and 110 Uigur). Allele frequencies and mutation rates of the 13 non‐CODIS STR loci were investigated. A total of 4–10 alleles at each locus were observed and altogether 84, 88, and 87 alleles for the all selected loci were found in the Mongol, Kazakh, and Uigur, respectively. Eight mutations were detected from the 13 selected loci in 9880 meioses in kinship cases. These results indicate that this multiplex system may provide significant polymorphic information for kinship testing and relationship investigations.  相似文献   

16.
A label‐free DNA biosensor based on three‐dimensional reduced graphene oxide (3D‐rGO) and polyaniline (PANI) nanofibers modified glassy carbon electrode (GCE) was successfully developed for supersensitive detection of breast cancer BRCA1. The results demonstrated that 3D‐rGO and PANI nanofibers had synergic effects for reducing the charge transfer resistance (Rct), meaning a huge enhancement in electrochemical activity of 3D‐rGO‐PANI/GCE. Probe DNA could be immobilized on 3D‐rGO‐PANI/GCE for special and sensitive recognition of target DNA (1.0×10?15–1.0×10?7 M) with a theoretical LOD of 3.01×10?16 M (3S/m). Furthermore, this proposed nano‐biosensor could directly detect BRCA1 in real blood samples.  相似文献   

17.
Electrochemical methods represent an important class of widely used techniques for the detection of metal ions. The unique chemical and physical properties of nanoparticles make them extremely suitable for designing new and improved sensing devices, especially electrochemical sensors and biosensors. This study focused on the synthesis of a nano‐Fe(III)–Sud complex and its characterization using various spectroscopic and analytical tools, optimized using the density functional theory method, screened for antibacterial activity and evaluated for possible binding to DNA using molecular docking study. Proceeding from the collected information, nano‐Fe(III)–Sud was used further for constructing carbon paste and screen‐printed ion‐selective electrodes. The proposed sensors were successfully applied for the determination of Fe(III) ions in various real and environmental water samples. Some texture analyses of the electrode surface were conducted using atomic force microscopy. At optimum values of various conditions, the proposed electrodes responded towards Fe(III) ions linearly in the range 2.5 × 10?9–1 × 10?2 and 1.0 × 10?8–1 × 10?2 M with slope of 19.73 ± 0.82 and 18.57 ± 0.32 mV decade?1 of Fe(III) ion concentration and detection limit of 2.5 × 10?9 and 1.0 × 10?8 M for Fe(III)–Sud‐SPE (electrode I) and Fe(III)–Sud‐CPE (electrode II), respectively. The electrode response is independent of pH in the range 2.0–7.0 and 2.5–7.0, with a fast response time (4 and 7 s) at 25°C for electrode I and electrode II, respectively. Moreover, the electrodes also showed high selectivity and long lifetime (more than 6 and 3 months for electrode I and electrode II, respectively). The electrodes showed good selectivity for Fe(III) ions among a wide variety of metal ions. The results obtained compared well with those obtained using atomic absorption spectrometry.  相似文献   

18.
This study describes the development of an analytical methodology based on the use of microchip electrophoresis (ME) devices integrated with capacitively coupled contactless conductivity detection (C4D) for the separation and detection of inorganic anions in post‐blast explosive residues. The best separation condition was achieved using a running buffer composed of 35 mmol/L lactic acid, 10 mmol/L histidine and 0.070 mmol/L cetyl(trimethyl ammonium) bromide. For C4D measurements, the highest sensitivity was obtained applying a 700 kHz sinusoidal wave with excitation voltage of 20 Vpp. The separation of Cl?, NO3?, NO2?, SO42?, ClO4? and ClO3? was performed within ca. 150 s with baseline resolution and efficiencies between 4.4 × 104 and 1.7 × 105 plates/m. The found limits of detection ranged between 2.5 and 9.5 μmol/L. Last, real samples of post‐blast explosive residues were analyzed on the ME‐C4D devices obtaining successfully the determination of Cl?, NO3? and SO42?. The achieved concentration values varied between 12.8–72.5 mg/L for Cl?, 1.7–293.1 mg/L for NO3? and 1.3–201.3 mg/L for SO42?. The data obtained using ME‐C4D devices were in good agreement with the concentrations found by ion chromatography. The approach reported herein has provided short analysis time, instrumental simplicity, good analytical performance and low cost. Furthermore, the ME‐C4D devices emerge as a powerful and portable analytical platform for on‐site analysis demonstrating to be a promising tool for the crime scene investigation.  相似文献   

19.
Shi Y  Anderson RC 《Electrophoresis》2003,24(19-20):3371-3377
Plastic microchannels (4.5 cm long) fabricated from an etched glass master were tested for high-resolution single-stranded DNA analysis. Using replaceable denaturing linear polyacrylamide as sieving matrix, one-color separation of a fragment sizing standard with single-base resolution (R > 0.5) was achieved up to 275 bases. Two-color sizing analysis of four loci short tandem repeat (STR) allelic ladder (CSF1PO, TPOX, TH01, vWA) with single-base resolution (R = 0.62) on TH01 alleles 9.3 (198 bp) and 10 (199 bp) was demonstrated. An average standard deviation of +/- 0.06 bp and +/-0.11 bp in sizing 32 alleles of the CTTv ladder was attained between runs and between channels, respectively. Four-color sequencing separation of a terminator sequencing standard showed a base-calling accuracy of 99.1% out to 320 bases in 13 min.  相似文献   

20.
Selenocysteine (Sec) is a crucial component of mammalian thioredoxin reductase (TrxR) where it serves as a nucleophile for disulfide bond rupture in thioredoxin (Trx). Generation of the reduced state of Sec in TrxR requires consecutive two electron transfer steps, namely: (i) from NADPH to flavin adenine dinucleotide, (ii) from reduced flavin to the disulfide bond Cys59‐S‐S‐Cys64, and finally (iii) from Cys59 and Cys64 to the selenosulfide bond Cys497‐S‐Se‐Sec498. In this work, we studied the reaction between reduced riboflavin (RibH2) and selenocystine (Sec‐Sec), an oxidized form of Sec. The interaction between RibH2 and Sec‐Sec proceeded relatively slowly in comparison with its reverse reaction, that is, reduction of riboflavin (Rib) by Sec. The rate constant for the reaction between RibH2 and Sec‐Sec was (7.9 ± 0.1) × 10?2 M?1 s?1 (pH 7.0, 25.0°C). The reaction between Rib and Sec proceeded via two steps, namely, a rapid reversible binding of Rib to Sec having a protonated selenol group to form a Sec‐Rib complex, followed by nucleophilic attack of Sec‐Rib by a second Sec molecule harboring a deprotonated selenol group. The equilibrium constant for the overall reduction process of Rib by Sec is (1.2 ± 0.1) × 106 M?1 (25.0°C). The finding that the interaction of RibH2 with oxidized selenol is reversible with its equilibrium favored toward the reverse reaction provides an additional explanation for the exceptional mechanism of the mammalian Trx/TrxR system involving transient reduction of a disulfide bond.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号