首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In this work, the reduced graphene oxide functionalized with poly dimethyl diallyl ammonium chloride (PDDA) modified palladium nanoparticles (PDDA‐rGO/Pd) had been facile synthesized and used as the sensing layer for sensitive determination of capsaicin. The prepared composite was characterized by transmission electron microscopy, UV‐visible absorption spectroscopy. The image demonstrated that Pd nanoparticles were uniformly distributed on the graphene surface. The electrochemical properties of the prepared sensor were investigated by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The results showed that the nanocomposite exhibits attractive electrocatalytic activity towards the oxidation of capsaicin. This attributed to the synergistic action of the excellent properties of Pd nanoparticles and graphene nanosheets. Under optimized conditions, the electrochemical sensor possessed a dynamic linear range from 0.32 μM to 64 μM with a detection limit of 0.10 μM (S/N=3) for capsaicin detection. Moreover, the cost‐effective and simple fabrication procedure, good reproducibility and stability as well as acceptable accuracy for capsaicin determination in actual samples are also the main advantages of this method, which might have broad application in other amide alkaloid detection.  相似文献   

2.
This work presents a simple method to fabricate an octahedral cuprous oxide (Cu2O) decorated two-dimensional (2D) flexible rGOP electrode with filtration and electrodeposition strategies. The characteristic of the Cu2O/rGOP electrodes was recorded by SEM, EDX, XPS, XRD, and Raman spectroscopy. The results clearly showed that Cu2O was successfully electrodeposited on the surface of rGOP by controlling the electrodeposition potential without the introduction of any template or surfactant. The electrochemical characterizations of the Cu2O/rGOP exhibited high electrocatalytic activity toward the reduction of H2O2. The linear detection range for the Cu2O/rGOP flexible sensor was 5.0 μM to 5.5 mM, with a limit of detection of 1.27 μΜ. Subsequently, the developed flexible rGOP sensor was extended for H2O2 detection in milk samples for avoiding milk spoilage. Such judicial preparation of rGOP as a sensing device will certainly pave the way for various other sensing applications including environmental and biomedical applications.  相似文献   

3.
《Analytical letters》2012,45(17):2786-2798
Prussian blue has significant application for the construction of electrochemical biosensors. In this work, Prussian blue-reduced graphene oxide modified glass carbon electrodes were successfully fabricated using electrochemical deposition. The high surface area of graphene oxide enhanced the deposition of Prussian blue and the resulting electrocatalytic activity. Infrared spectroscopy and scanning electron microscopy showed that the relatively porous Prussian blue was on the surface of reduced graphene oxide. Cyclic voltammetry showed that Prussian blue-coated reduced graphene oxide composite films improved electron transfer compared to Prussian blue films. The Prussian blue-reduced graphene oxide composite film provided higher response for the reduction of hydrogen peroxide and the oxidation of dopamine compared with the Prussian blue film due to synergistic effects between the reduced graphene oxide and Prussian blue particles. The sensitivity of the electrode was 0.1617 µA µM?1 cm?2. The linear dynamic range extended from 0.5 µM to 0.7 mM dopamine with a limit of detection equal to 125 nM. This work provided a versatile strategy for the design and construction of sensitive amperometric sensors with robust electrocatalytic behavior.  相似文献   

4.
In the present study, we report the simultaneous electrochemical determination of hydroquinone (HQ), catechol (CC) and resorcinol (RC) at gold nanoparticles (Au‐NPs) decorated reduced graphene oxide (RGO) modified electrode. An enhanced and well defined peak current response with a better peak separation of HQ, CC and RC is observed at RGO/Au‐NPs composite than that of RGO and Au‐NPs modified electrodes. The fabricated modified electrode shows a wide linear response in the concentration range of 3–90 µM, 3–300 µM and 15–150 µM for HQ, CC and RC, respectively. The detection limit of HQ, CC and RC is found as 0.15 µM, 0.12 µM and 0.78 µM, respectively.  相似文献   

5.
A novel nonenzymatic glucose sensor was developed based on well‐dispersed gold nanoparticles, which were in situ grown under direction of protein on a reduced graphene oxide modified electrode. This electrode exhibited high electrocatalytic activity towards glucose oxidation without use of any enzyme or mediator. In application for the amperometric detection of glucose, a wide linear range of 0.02–16.6 mM, low detection limit of 5 µM and good selectivity were obtained. The attractive analytical performances of the proposed glucose sensor, coupled with the facile preparation method, provide a promising electrochemical platform for the development of effective nonenzymatic sensors.  相似文献   

6.
In this study, magnetite nanorods stabilized on polyaniline/reduced graphene oxide (Fe3O4@PANI/rGO) was synthesized via a wet‐reflux strategy. The possible formation of Fe3O4@PANI/rGO was morphologically and structurally verified by field emission scanning electron microscopy (FE‐SEM), Fourier transform infrared (FT‐IR) spectroscopy, Raman spectroscopy, X‐ray diffraction (XRD) and X‐ray photoelectron spectroscopy (XPS). Furthermore, the thermal stability of Fe3O4@PANI/rGO was measured by a thermogravimetric analyzer (TGA); the composite had good thermal stability owing to the ceramic nature of Fe3O4. The Fe3O4@PANI/rGO has been applied as a potential sensing platform for electrochemical detection of hydrogen peroxide (H2O2). By the combined efforts of extended active surface area, active carbon support, more catalytic active sites and high electrical conductivity, the Fe3O4@PANI/rGO exhibited an improved performance toward the non‐enzymatic detection of H2O2 in 0.5 M KOH with a fast response time (5 s), high sensitivity (223.7 μA mM?1 cm?2), low limit of detection (4.45 μM) and wide linear range (100 μM–1.5 mM). Furthermore, the fabricated sensor exhibited excellent recovery rates (94.2–104.0 %) during real sample analysis.  相似文献   

7.
《Electroanalysis》2017,29(2):345-351
A glassy carbon electrode modified with reduced graphene oxide and platinum nanocomposite film was developed simply by electrochemical method for the sensitive and selective detection of nitrite in water. The electrochemical reduction of graphene oxide (GO) efficiently eliminates oxygen‐containing functional groups. Pt nanoparticles were electrochemically and homogeneously deposited on the ErGO surface. Field emission scanning electron microscopy (FE‐SEM), Raman spectroscopy, attenuated total reflectance‐fourier transform infrared spectroscopy (ATR‐FTIR), electrochemical impedance spectroscopy (EIS), and cyclic voltammetry (CV) were used to examine the surface morphology and electrocatalytic properties of the Pt‐ErGO nanocomposite film‐modified electrode surface. The fabricated nitrite sensor showed good electrochemical performance with two linear ranges; one from 5 to 100 µM (R2=0.9995) and the other from 100 to 1000 µM (R2=0.9972) and a detection limit of 0.22 µM. The proposed sensor was successfully applied for the detection of nitrite in tap water samples which proves performance of the Pt‐ErGO nanocomposite films.  相似文献   

8.
A very sensitive electrochemical sensor based on a reduced graphene oxide film impregnated with antimony nanoparticles was prepared and applied to the electroanalysis of platinum group metal ions of Pd(II), Pt(II) and Rh(III). The electrochemical behavior of platinum group metals at the modified electrode was studied by adsorptive differential pulse cathodic stripping voltammetry in the presence of dimethylglyoxime as chelating agent. Several operational parameters were optimised to enhance the electroanalytical performance of the modified glassy carbon electrode sensor. The results showed sharp stripping peaks and a relatively constant peak potential with a good linear behaviour in the examined concentration range from 40 to 400 pg L?1 for all metal ions investigated. The detection limit was found to be 0.45, 0.49 and 0.49 pg L?1 (S/N=3) for Pd(II), Pt(II) and Rh(III), respectively. The developed electrochemical sensor also exhibited good precision with a relative standard deviation of 4.2 %, 2.55 % and 2.67 % for 5 successive measurements for Pd(II), Pt(II) and Rh(III), respectively. The proposed nanostructure showed good sensitivity and stability, which has promising potential applications in electrochemical sensors.  相似文献   

9.
《Electroanalysis》2018,30(1):194-203
Glassy carbon electrode (GCE) modified with L‐cysteine and gold nanoparticles‐reduced graphene oxide (AuNPs‐RGO) composite was fabricated as a novel electrochemical sensor for the determination of Cu2+. The AuNPs‐RGO composite was formed on GCE surface by electrodeposition. The L‐cysteine was decorated on AuNPs by self‐assembly. Physicochemical and electrochemical properties of L‐cysteine/AuNPs‐RGO/GCE were characterized by scanning electron microscopy, atomic force microscopy, energy dispersive spectroscopy, Raman spectroscopy, X‐ray diffraction, cyclic voltammetry and adsorptive stripping voltammetry. The results validated that the prepared electrode had many attractive features, such as large electroactive area, good electrical conductivity and high sensitivity. Experimental conditions, including electrodeposition cycle, self‐assembly time, electrolyte pH and preconcentration time were studied and optimized. Stripping signals obtained from L‐cysteine/AuNPs‐RGO/GCE exhibited good linear relationship with Cu2+ concentrations in the range from 2 to 60 μg L−1, with a detection limit of 0.037 μg L−1. Finally, the prepared electrode was applied for the determination of Cu2+ in soil samples, and the results were in agreement with those obtained by inductively coupled plasma mass spectrometry.  相似文献   

10.
制备了一种二氧化锆/还原氧化石墨烯(ZrO2NPs/rGO)复合材料修饰电极的亚硝酸盐电化学传感器,并成功用于亚硝酸盐的检测.采用循环伏安法和电流-时间曲线考察了修饰电极的电化学行为.实验结果表明,ZrO2NPs/rGO复合材料修饰电极对亚硝酸盐具有良好的电流响应.在最优实验条件下,电流-时间曲线中的电流响应信号与亚硝酸盐浓度在3.0×10Symbolm@@_7~1.0×10Symbolm@@_6 mol/L和1.0×10Symbolm@@_6~6.0×10Symbolm@@_6 mol/L的范围内呈良好的线性关系,检测限为1.0×10Symbolm@@_7 mol/L(S/N 3).该传感器灵敏性高、稳定性和重现性好.使用此传感器检测实际样品香肠中的亚硝酸盐的回收率为93.7%~110.4%,相对标准偏差为1.6%~2.1%.  相似文献   

11.
王丽  马俊红 《物理化学学报》2001,30(7):1267-1273
采用高温热解聚苯胺修饰的氧化石墨烯(PANI-GO),得到了氮掺杂的还原氧化石墨烯碳材料(N-RGO),以其负载Pt 制备了Pt/N-RGO纳米结构电催化剂. 采用透射电镜(TEM)、X射线光电子能谱(XPS)、X 射线衍射(XRD)谱及拉曼光谱等技术对N-RGO和Pt/N-RGO的形貌及结构进行了表征,用循环伏安、计时电流等电化学技术研究了Pt/N-RGO电极催化剂对CO溶出反应和甲醇电氧化反应的催化性能. 结果表明:高温热解PANIGO可同时实现GO的还原及其氮掺杂的过程,氮掺杂引起还原氧化石墨烯碳材料表面缺陷结构和导电性的增加;与相应的未掺杂氮样品Pt/RGO相比较,Pt/N-RGO样品上Pt 颗粒的分散更均匀,显示出更强的抗CO毒化能力和更高的甲醇电氧化催化活性及稳定性.  相似文献   

12.
Zenghong Xu  Chun He  Tao Sun  Li Wang 《Electroanalysis》2013,25(10):2339-2344
A highly sensitive thrombin electrochemical aptasensor with Pt nanoparticles, blocking reagent‐horseradish peroxidase (HRP) and inert graphene oxide (GO) as enhancers was successfully fabricated. Firstly, Pt nanoparticles with high surface to volume ratio could increase the amount of the immobilized redox probe hexacyanoferrate nanoparticles (NiHCFNPs) and effectively enhance the electron transfer. Secondly, HRP and Pt nanoparticles with high catalytic activity extremely amplify the electrochemical signal of NiHCFNPs toward H2O2. Lastly, inert graphene oxide (GO) labeled TBA could be used for enlarging the steric hindrance of thrombin. As a result, the aptasensor showed a high sensitivity with a detection limit of 500 fM.  相似文献   

13.
Peng Qi  Yi Wan  Dun Zhang  Jiajia Wu 《Electroanalysis》2011,23(12):2796-2801
This paper describes a new electrochemical sensor based on reduced graphene sheets (RGSs) modified glassy carbon electrodes for rapid detection of sulfide. The morphology and electrochemical properties of the RGSs are characterized by atomic force microscopy and cyclic voltammetry. The effects of the scan rates and pH are investigated to evaluate the oxidation processes. Analytical performances of RGSs modified electrodes for direct determination of sulfide in phosphate buffer solutions (PBSs) are also assessed. The RGSs are shown to be viable potential material for sulfide detection as shown by their electrochemical performance.  相似文献   

14.
A sensitive hydrogen peroxide (H2O2) biosensor was developed based on a reduced graphene oxide|carbon ceramic electrode (RGO|CCE) modified with cadmium sulfide‐hemoglobin (CdS‐Hb). The electron transfer kinetics of Hb were promoted due to the synergetic function of RGO and CdS nanoparticles. The transfer coefficient (α) and the heterogeneous electron transfer rate constant (ks) were calculated to be 0.54 and 2.6 s?1, respectively, indicating a great facilitation achieved in the electron transfer between Hb and the electrode surface. The biosensor showed a good linear response to the reduction of H2O2 over the concentration range of 2–240 µM with a detection limit of 0.24 µM (S/N=3) and a sensitivity of 1.056 µA µM?1 cm?2. The high surface coverage of the CdS‐Hb modified RGO|CCE (1.04×10?8 mol cm?2) and a smaller value of the apparent Michaelis? Menten constant (0.24 mM) confirmed excellent loading of Hb and high affinity of the biosensor for hydrogen peroxide.  相似文献   

15.
采用高温热解聚苯胺修饰的氧化石墨烯(PANI-GO),得到了氮掺杂的还原氧化石墨烯碳材料(N-RGO),以其负载Pt制备了Pt/N-RGO纳米结构电催化剂.采用透射电镜(TEM)、X射线光电子能谱(XPS)、X射线衍射(XRD)谱及拉曼光谱等技术对N-RGO和Pt/N-RGO的形貌及结构进行了表征,用循环伏安、计时电流等电化学技术研究了Pt/N-RGO电极催化剂对CO溶出反应和甲醇电氧化反应的催化性能.结果表明:高温热解PANIGO可同时实现GO的还原及其氮掺杂的过程,氮掺杂引起还原氧化石墨烯碳材料表面缺陷结构和导电性的增加;与相应的未掺杂氮样品Pt/RGO相比较,Pt/N-RGO样品上Pt颗粒的分散更均匀,显示出更强的抗CO毒化能力和更高的甲醇电氧化催化活性及稳定性.  相似文献   

16.
《Electroanalysis》2017,29(5):1278-1285
The composite material of reduced graphene and Ru nanoparticles (rGO/RuNP) was obtained by electrochemical oxidation of ruthenium nanoparticles immobilised on the glassy carbon electrode (GCE) surface and used for simultaneous electroanalysis of drugs. There are many discussions in the scientific community about the decrease in therapeutic efficacy of contraceptives when associated with antibiotics. The antibiotic effect of the antagonist can increase the contraceptive excretion levels in urine, indicating a reduction in the body and thus a decrease in the desired effect. Using the DPV technique, it was possible to quantify ethinylestradiol (EE2) and amoxicillin (AMX) with a linear response range, 5.50x10−8 – 1.20x10−6 mol L−1, and LOD, 2.04 nmol L−1 and 1.63 nmol L−1, respectively. The results for the electrochemical behaviour of EE2 and AMX using GCE/rGO/RuNP were compared with GCE/rGO and GCE. The GCE/rGO/RuNP showed greater stability and separation anodic peak currents, suitable for the quantification of organic molecules in samples of environmental interest, as well as clinical and food samples.  相似文献   

17.
In this paper, electromembrane extraction coupled with differential pulse voltammetry (DPV) on a reduced graphene oxide modified screen‐printed carbon electrode (RGO‐SPCE) for the determination of dextromethorphan (DXM) in urine and plasma has been described. DXM migrated from 4 mL of a donor phase across a thin layer of 2‐nitrophenyl octyl ether (NPOE) immobilized in the pores of a porous hollow fiber, into a 20 µL acceptor phase (HCl) present inside the lumen of the fiber. Then, 15 µL of a 0.1 M NaOH solution was added to the acceptor phase and the mixture was analyzed using DPV.  相似文献   

18.
组装高能量密度的非对称超级电容器需要使用比电容大、 体积变化小且循环稳定性好的电极材料. 过渡金属硫化物(TMSs)与纳米碳材料的复合物是此类电极材料之一. 采用水热法合成了由Cu-Mo硫化物在微波剥离的还原氧化石墨烯表面生长的复合材料(CuS-MoS2/MErGO). 此复合材料在电流密度为2 A/g时具有高达861.5 F/g的比电容和良好的循环稳定性. 将1.6 V的电池电压施加在由NiS/MErGO为正极, CuS-MoS2/MErGO为负极组装成的不对称超级电容器上时, 该电容器的功率密度为1.28 kW/kg, 且能量密度保持为54.2 W·h·kg-1. 结果表明, TMS复合材料是一种很有前途的高性能电化学储能材料, 尤其是用于非对称超级电容器的组装.  相似文献   

19.
A highly sensitive and selective chemical sensor was prepared based on metallic copper‐copper oxides and zinc oxide decorated graphene oxide modified glassy carbon electrode (Cu?Zn/GO/GCE) through an easily electrochemical method for the quantification of bisphenol A (BPA). The composite electrode was characterized via scanning electron microscopy (SEM), X‐Ray photoelectron spectroscopy (XPS) and electrochemical impedance spectroscopy (EIS). The electrochemical behavior of BPA in Britton‐Robinson (BR) buffer solution (pH 7.1) was examined using cyclic voltammetry (CV). Under optimized conditions, the square wave voltammetry (SWV) response of Cu?Zn/GO/GCE towards BPA indicates two linear relationships within concentrations (3.0 nmol L?1?0.1 μmol L?1 and 0.35 μmol L?1?20.0 μmol L?) and has a low detection limit (0.88 nmol L?1). The proposed electrochemical sensor based on Cu?Zn/GO/GCE is both time and cost effective, has good reproducibility, high selectivity as well as stability for BPA determination. The developed composite electrode was used to detect BPA in various samples including baby feeding bottle, pacifier, water bottle and food storage container and satisfactory results were obtained with high recoveries.  相似文献   

20.
Enhanced methods of drug monitoring are required to support the individualization of therapeutic drug dosing. Clozapine is one of the most important medications for managing schizophrenia, and timely measurement of serum clozapine levels has been identified as a barrier to the broader use of clozapine. For the first time, reduced graphene oxide nanocomposites were used to construct an electrochemical clozapine (Clz) sensor. The Reduced graphene oxide (Rego) nanocomposites were synthesized and characterized by using X-Ray Diffraction (XRD), Fourier-Transform Infrared Spectroscopy (FTIR), Scanning Electron Microscopy (SEM), and Transmission Electron Microscopy (TEM) techniques. The Clz sensing electrode was fabricated by drop coating of Rego nanocomposites suspension and Nafion solution on the pencil graphite electrode, respectively. The electrochemical behavior and influence of various physicochemical parameters of sensing electrodes were investigated by using cyclic voltammetry (CV) and differential voltammetry (DPV) techniques. The designed sensor displayed decent linear range, detection limit, reproducibility, and reusability results. Under optimum experimental parameters a linear dynamic range of 0.05–10 μM clozapine was observed with actual detection limit of 50 nM. Furthermore, the designed sensing electrode was used to measure the amount of Clz in real samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号