首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 796 毫秒
1.
A sensitive and specific LC/MS/MS method was developed for the simultaneous analysis of 35 compounds used for treating hypertension as adulterants in dietary supplements. The method was validated for specificity, linearity, accuracy, precision, limit of detection, limit of quantitation, stability and recovery. The limit of detection and limit of quantitation ranged from 0.20 to 20.0 and 0.50 to 60.0 ng/g, respectively. The linearity was good (r 2 > 0.999), with intra‐ and interday precision levels of 0.43–7.87% and 0.65–9.95% and the intra‐ and interday accuracies of 84.36–115.82% and 83.78–118.69%, respectively. The stability (relative standard deviation) was <14.75%. The mean recovery was 80.81–117.86% (relative standard deviation <10.00%). Ninety‐seven commercial dietary supplements available in South Korea were analyzed. While none contained detectable amounts of the 35 antihypertensive compounds, the developed LC/MS/MS procedure can be used for routine analysis to monitor illegal adulteration in various forms of dietary supplements.  相似文献   

2.
Complete resolution of hydroxyeicosatetraenoic acid (HETE) enantiomers was achieved using hydroxypropyl‐γ‐cyclodextrin (HP‐γ‐CD)‐modified MEKC. The optimum running conditions were determined to be utilizing a 30 mM phosphate–15 mM borate buffer (pH 9.0) containing 30 mM HP‐γ‐CD and 75 mM SDS as the BGE, application of +30 kV as the effective voltage, and carrying out the experiment at 15°C. The eluents were detected at 235 nm. The method was used successfully for the simultaneous separations of (S)‐ and (R)‐enantiomers of regioisomeric 8‐, 11‐, 12‐, and 15‐HETEs. Subsequently, the optimized method was applied to evaluate the stereochemistry of 8‐ and 12‐HETEs from the marine red algae, Gracilaria vermiculophylla and Gracilaria arcuata, respectively. The 8‐HETE was found to be a mixture of 98% (R)‐enantiomer and 2% (S)‐enantiomer, while the 12‐HETE was a mixture of 98% (S)‐enantiomer and 2% (R)‐enantiomer. The present study demonstrates that the HP‐γ‐CD‐modified MEKC method is simple and sensitive and provides unambiguous information on the configuration of natural and synthetic HETEs.  相似文献   

3.
A simple, rapid and sensitive method has been developed and validated for the determination of pramipexole in rat plasma by using gas chromatography mass spectrometry. The lower limit of quantification (LLOQ) is superior to the other reported LC‐MS/MS methods. After being made alkaline with NaOH, plasma samples (0.1 mL) were subjected to liquid–liquid exteraction using methyl‐t‐butyl ether. Analytes were determined using electron impact ionization in a single quadrupole mass spectrometer. GC/MS was performed in the selected ion monitoring mode using target ions at m/z 211, 212 and 152 for pramipexole and m/z 194 and 165 for caffeine as internal standard. A linear calibration curve was plotted over the range of 20–1000 pg/mL for pramipexole (r2 > 0.996). The LLOQ was 20.0 pg/mL, respectively, which offered high sensitivity and selectivity enough for bioanalytical investigation. Inter‐ and intraday precisions ranged from 0.3 to 8.8% and from 0.9 to 11.33%, respectively. The recovery of pramipexole from plasma ranged from 82.4 ± 7.1 to 87.8 ± 5.7%. The method fulfills all standards required for bioanalytical methods and can be successfully applied to a pharmacokinetic study of pramipexole in rats. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

4.
A simple sample treatment procedure and sensitive liquid chromatography–tandem mass spectrometry method were developed for the simultaneous quantification of the concentrations of human immunodeficiency virus‐1 integrase strand transfer inhibitors – raltegravir, dolutegravir and elvitegravir – in human plasma and cerebrospinal fluid (CSF). Plasma and CSF samples (20 μL each) were deproteinized with acetonitrile. Raltegravir‐d3 was used as the internal standard. Chromatographic separation was achieved on an XBridge C18 column (50 × 2.1 mm i.d., particle size 3.5 μm) using acetonitrile–water (7:3, v/v) containing 0.1% formic acid as the mobile phase at a flow rate of 0.2 mL/min. The run time was 5 min. Calibration curves for all three drugs were linear in the range 5–1500 ng/mL for plasma and 1–200 ng/mL for CSF. The intra‐ and inter‐day precision and accuracy of all three drugs in plasma were coefficient of variation (CV) <12.9% and 100.0 ± 12.2%, respectively, while those in CSF were CV <12.3% and 100.0 ± 7.9%, respectively. Successful validation under the same LC–MS/MS conditions for both plasma and CSF indicates this analytical method is useful for monitoring the levels of these integrase strand transfer inhibitors in the management of treatment of HIV‐1 carriers.  相似文献   

5.
The aim of the present study was to develop a method based on gas chromatography–tandem mass spectrometry (GC–MS/MS) to determine and quantify the d ‐limonene in mouse plasma and tissue samples. This new method was validated for the quantification of d ‐limonene with the linearity ranges 1.0–1000.0 ng/mL (r2 > 0.9952) for plasma samples and 5.0–5000.0 ng/g (r2 > 0.9940) for tissue samples. The intra‐ and inter‐day assay of precisions in plasma and tissues were <13.4% and the accuracies were within 91.1–105.8%. In the oral/inhalation administration pharmacokinetics and tissue distribution studies, the main pharmacokinetic parameters were the peak concentration = (97.150 ± 34.450)/(4336.415 ± 1142.418) ng/mL, the area under the curve = (162.828± 27.447)/(2085.721 ± 547.787) h ng/mL and the half‐life = (3.196 ± 0.825)/(0.989 ± 0.095) h. The tissue distribution of d ‐limonene in mice after oral/inhalation administration demonstrated a decreasing tendency in different tissues (liver > kidney > heart > lung > spleen).  相似文献   

6.
A sensitive and specific ultra‐performance liquid chromatography–tandem mass spectrometry (UPLC‐MS‐MS) method for quantification of a newly developed anticancer agent NPD‐103 has been established. An aliquot of human plasma sample (200 µL) was spiked with 13C‐labeled paclitaxel (internal standard) and extracted with 1.3 mL of tert‐butyl methyl ether. NPD‐103 was quantitated on a C18 column with methanol–0.1% formic acid (75:25, v/v) as mobile phase using UPLC‐MS‐MS operating in positive electrospray ionization mode with a total run time of 3.0 min. For NPD‐103 at the concentrations of 1.0, 5.0 and 10.0 µg/mL in human plasma, the absolute extraction recoveries were 95.58, 102.43 and 97.77%, respectively. The linear quantification range of the method was 0.1–20.0 µg/mL in human plasma with linear correlation coefficients greater than 0.999. The intra‐ and inter‐day accuracy for NPD‐103 at 1.0, 5.0 and 10.0 µg/mL levels in human plasma fell into the ranges of 95.29–100.00% and 91.04–94.21%, and the intra‐ and inter‐day precisions were in the ranges of 8.96–11.79% and 7.25–10.63%, respectively. This assay is applied to determination of half‐life of NPD‐103 in human plasma. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

7.
Complex formation between N‐butylboronic acid and D ‐(+)‐glucose, D ‐(+)‐mannose, methyl‐α‐D ‐glucopyranoside, methyl‐β‐D ‐galactopyranoside and methyl α‐D ‐mannopyranoside under neutral conditions was investigated by 1H, 13C and 11B NMR spectroscopy and gas chromatography–mass spectrometry (GC–MS) D ‐(+)‐Glucose and D ‐(+)‐mannose formed complexes where the boronates are attached to the 1,2:4,6‐ and 2,3:5,6‐positions of the furanose forms, respectively. On the other hand, the boronic acid binds to the 4,6‐positions of the two methyl derivatives of glucose and galactose. Methyl α‐D ‐mannopyranoside binds two boronates at the 2,3:4,6‐positions. 11B NMR was used to show the ring size of the complexed sugars and the boronate. GC–MS confirmed the assignments. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

8.
A liquid chromatographic–tandem mass spectrometric (LC‐MS/MS) method was developed and validated for the determination of GDC‐0834 and its amide hydrolysis metabolite (M1) in human plasma to support clinical development. The method consisted of semi‐automated 96‐well protein precipitation extraction for sample preparation and LC‐MS/MS analysis in positive ion mode using TurboIonSpray® for analysis. D6‐GDC‐0834 and D6‐M1 metabolite were used as internal standards. A linear regression (weighted 1/concentration2) was used to fit calibration curves over the concentration range of 1 – 500 ng/mL for both GDC‐0834 and M1 metabolite. The accuracy (percentage bias) at the lower limit of quantitation (LLOQ) was 5.20 and 0.100% for GDC‐0834 and M1 metabolite, respectively. The precision (CV) for samples at the LLOQ was 3.13–8.84 and 5.20–8.93% for GDC‐0834 and M1 metabolite, respectively. For quality control samples at 3, 200 and 400 ng/mL, the between‐run CV was ≤7.38% for GDC‐0834 and ≤8.20% for M1 metabolite. Between run percentage bias ranged from ?2.76 to 6.98% for GDC‐0834 and from ?6.73 to 2.21% for M1 metabolite. GDC‐0834 and M1 metabolite were stable in human plasma for 31 days at ?20 and ?70°C. This method was successfully applied to support a GDC‐0834 human pharmacokinetic‐based study. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

9.
The purpose of this study was to develop and validate an LC–MS/MS method for simultaneous determination of idelalisib and GS‐563117 in dog plasma. The analytes were extracted using ethyl acetate and then separated on a Waters Acquity UPLC BEH C18 column (50 × 2.1 mm, i. d., 1.7 μm) using 0.1% formic acid in water and acetonitrile as mobile phase at a flow rate of 0.3 mL/min in gradient elution mode. The analytes were quantified using selected reaction monitoring with precursor‐to‐product transitions at m/z 416.2 → 176.1, m/z 432.2 → 192.1 and m/z 421.2 → 176.1 for idelalisib, GS‐563117 and [2H5]‐idelalisib (internal standard). The assay showed good linearity (r > 0.9992) over the tested concentration range of 0.1–600 ng/mL for idelalisib and 0.1–300 ng/mL for GS‐563117. The intra‐ and inter‐day RSD values for idelalisib and GS‐563117 were <8.84 and 12.41%, respectively. The intra‐ and inter‐day RE values were within the range of ?7.21–8.52%, and ?6.44–14.23%, respectively. The extraction recovery was found to be >84.59% and no matrix effects were observed. The validated LC–MS/MS method has been successfully applied for the simultaneous determination of idelalisib and GS‐563117 in a pharmacokinetic study in dogs. Our results suggested that idelalisib was rapidly metabolized into its metabolite GS‐563117 in dog and the in vivo exposure of GS‐563117 was 17.59% of that of idelalisib.  相似文献   

10.
Paralytic shellfish toxins (PSTs) are produced by marine and freshwater microalgae and accumulate in shellfish including mussels, oysters, and scallops, causing possible fatalities when inadvertently consumed. Monitoring of PST content of shellfish is therefore important for food safety, with currently approved methods based on HPLC, using pre‐ or postcolumn oxidation for fluorescence detection (HPLC‐FLD). CE is an attractive alternative for screening and detection of PSTs as it is compatible with miniaturization and could be implemented in portable instrumentation for on‐site monitoring. In this study, CE methods were developed for C4D, FLD, UV absorption detection, and MS—making this first report of C4D and FLD for PSTs detection. Because most oxidized toxins are neutral, MEKC was used in combination with FLD. The developed CZE‐UV and CZE‐C4D methods provide better resolution, selectivity, and separation efficiency compared to CZE‐MS and MEKC‐FLD. The sensitivity of the CZE‐C4D and MEKC‐FLD methods was superior to UV and MS, with LOD values ranging from 140 to 715 ng/mL for CZE‐C4D and 60.9 to 104 ng/mL for MEKC‐FLD. With the regulatory limit for shellfish samples of 800 ng/mL, the CZE‐C4D and MEKC‐FLD methods were evaluated for the screening and detection of PSTs in shellfish samples. While the CZE‐C4D method suffered from significant interferences from the shellfish matrix, MEKC‐FLD was successfully used for PST screening of a periodate‐oxidized mussel sample, with results confirmed by HPLC‐FLD. This confirms the potential of MEKC‐FLD for screening of PSTs in shellfish samples.  相似文献   

11.
A selective, sensitive and rapid liquid chromatography–tandem mass spectrometry (LC–MS/MS) method was developed and validated for the determination of tigecycline (TGC) in human plasma, using tigecycline‐d9 as an internal standard (IS). Analytical samples were prepared using a protein precipitation method coupled with a concentration process. The analyte and IS were separated on a reversed‐phase Waters Acquity UPLC® BEH‐C18 column (2.1 × 50 mm i.d., 1.7 μm) with a flow rate of 0.25 mL/min. The mobile phase consisted of water, containing 0.2% formic acid (v/v) with 10 mm ammonium formate (A) and acetonitrile (B). The mass spectrometer was operated in selected reaction monitoring mode through electrospray ionization ion mode using the transitions of m/z 586.2 → 513.1 and m/z 595.1 → 514.0 for TGC and IS, respectively. The linearity of the method was in the range of 10–5000 ng/mL. Intra‐ and inter‐batch precision (CV) for TGC was <9.27%, and the accuracy ranged from 90.06 to 107.13%. This method was successfully applied to the analysis of samples from hospital‐acquired pneumonia patients treated with TGC, and a validated population pharmacokinetic model was established. This developed method could be useful to predict pharmacokinetics parameters and valuable for further pharmacokinetics/pharmacodynamics studies.  相似文献   

12.
《Electrophoresis》2017,38(7):1075-1082
In this study, novel, fast, and simple methods based on RP‐HPLC and MEKC with DAD are developed and validated for the qualitative and quantitative determination of five cyclic sulfur mustard (HD) degradation products (1,4‐thioxane, 1,3‐dithiolane, 1,4‐dithiane, 1,2,5‐trithiepane, and 1,4,5‐oxadithiepane) in water samples. The HPLC method employs a C18 column and an isocratic water‐ACN (55:45, v/v) mobile phase. This method enables separation of all five cyclic compounds within 8 min. With the CE method, the baseline separation of five compounds was achieved in less than 11 min by applying a simple BGE composed of a 10 mM borate buffer and 90 mM SDS (pH 9.15). Both methods showed good linear correlation (R 2 > 0.9904). The detection limits were in the range of 0.08–0.1 μM for the HPLC method and 10–20 μM for MEKC. The precision tests resulted in RSDs for migration times and peak areas less than 0.9 and 5.5%, respectively, for the HPLC method, and less than 1.1 and 7.7% for the MEKC method, respectively. The developed methods were successfully applied to the analysis of five cyclic HD degradation products in water samples. With the HPLC method, the LODs were lowered using the SPE for sample purification and concentration.  相似文献   

13.
A rapid, specific and high‐throughput stable isotope‐dilution LC–MS/MS method was developed and validated with high sensitivity for the quantification of R‐ phencynonate (a eutomer of phencynonate racemate) in rat and dog plasma. Plasma samples were deproteinized using acetonitrile and then separated on a C8 column with an isocratic mobile phase containing acetonitrile–water–formic acid mixture (60:40:0.1, v /v/v) at a flow rate of 0.2 mL/min. Each sample had a total run time of 3 min. Quantification was performed using triple quadrupole mass spectrometry in selected reaction monitoring mode with positive electrospray ionization. The method was shown to be highly linear (r 2 > 0.99) and to have a wide dynamic range (0.1–100 ng/mL) with favourable accuracy and precision. No matrix effects were observed. The detailed pharmacokinetic profiles of R‐ phencynonate at therapeutic doses in rats and dogs were characterized by rapid oral absorption, quick clearance, high volume of distribution and poor absolute bioavailability. R‐ Phencynonate lacked dose proportionality over the oral dose range, based on the power model. However, the area under concentration–time curve and the maximum plasma concentration increased linearly in a dose‐dependent manner in both animal models. The absolute bioavailability of R‐ phencynonate was 16.6 ± 2.75 and 4.78 ± 1.26% in dogs and rats, respectively.  相似文献   

14.
15.
α‐Cedrene is a pharmacologically active ingredient isolated from the essential oil of cedar. A selective and sensitive GC–MS/MS method was developed for the quantification of α‐cedrene in rat plasma for the first time. α‐Cedrene was extracted from rat plasma using ethyl acetate at neutral pH. The analytes were determined in selective reaction monitoring mode using MS/MS: m/z 204.3→119.0 for α‐cedrene and m/z 146.0→111.0 for 1,4‐dichlorobenzene (internal standard). The standard curve was linear (r2 ≥ 0.995) over the concentration ranges of 5–800 ng/mL. The lower limit of quantification was 5 ng/mL using 50 μL of rat plasma. The coefficient of variation and relative error for intra‐ and interassays at four quality control levels were 3.1–13.9% and ?4.0–2.6%, respectively. The stability of processing (freeze–thaw, long‐term storage at ?80°C, and short‐term storage at room temperature) and chromatography (reinjection) was shown to be of insignificant effect. The present method was applied successfully to the pharmacokinetic study of α‐cedrene after its intravenous (10 mg/kg) and oral (25 mg/kg) administration in male Sprague‐Dawley rats.  相似文献   

16.
GC and HPLC with selective detectors were compared for simultaneous determination of triazine herbicides simazine, atrazine, propazine, terbuthylazine, cyanazine, ametryn, prometryn, and atraton, and of their dealkylated degradation products in soil. The compounds were ultrasonically extracted from spiked agricultural soil samples (organic matter content < 5%) with a 2:1 acetone:n‐hexane mixture. High efficiency of GC capillary column and high selectivity of the thermionic sensitive detector (TSD) and ion trap detector (ITD) made it possible to directly analyse uncleaned soil extracts and determine all 12 compounds in one run. In reversed‐phase HPLC with diode‐array detector (DAD), the co‐elution of soil matrix components interfered with the determination of methylthiotriazines and terbuthylazine. The recovery of triazine compounds, determined by GC‐TSD, from a silty sand soil (organic matter content 1.82%, pH 6.22) spiked at levels of 15–600 ng g–1, were 70–90% (RSD 9–19%), except for deisopropylatraton (38%). GC‐TSD analysis with detection limits of 5–15 ng g–1 for chloro‐ and methylthiotriazines and 30 ng g–1 for methoxytriazines was more sensitive than GC‐MS(ITD). GC analysis with electron capture detection was sensitive for some chlorotriazines, but a reliable compound quantification in complex chromatograms of uncleaned soil of extracts was not possible. For all compounds save didealkylatrazine, HPLC‐DAD was at least two times less sensitive than GC‐TSD. Soil/sediment organic matter, clay and silt content, and pH were identified as matrix characteristics which might affect ultrasonic extraction recovery of a particular compound.  相似文献   

17.
Precise measurement of low enrichment of stable isotope labeled amino‐acid tracers in tissue samples is a prerequisite in measuring tissue protein synthesis rates. The challenge of this analysis is augmented when small sample size is a critical factor. Muscle samples from human participants following an 8 h intravenous infusion of L‐[ring‐13C6]phenylalanine and a bolus dose of L‐[ring‐13C6]phenylalanine in a mouse were utilized. Liquid chromatography tandem mass spectrometry (LC/MS/MS), gas chromatography (GC) MS/MS and GC/MS were compared to the GC‐combustion‐isotope ratio MS (GC/C/IRMS), to measure mixed muscle protein enrichment of [ring‐13C6]phenylalanine enrichment. The sample isotope enrichment ranged from 0.0091 to 0.1312 molar percent excess. As compared with GC/C/IRMS, LC/MS/MS, GC/MS/MS and GC/MS showed coefficients of determination of R2 = 0.9962 and R2 = 0.9942, and 0.9217 respectively. However, the precision of measurements (coefficients of variation) for intra‐assay are 13.0%, 1.7%, 6.3% and 13.5% and for inter‐assay are 9.2%, 3.2%, 10.2% and 25% for GC/C/IRMS, LC/MS/MS, GC/MS/MS and GC/MS, respectively. The muscle sample sizes required to obtain these results were 8 µg, 0.8 µg, 3 µg and 3 µg for GC/C/IRMS, LC/MS/MS, GC/MS/MS and GC/MS, respectively. We conclude that LC/MS/MS is optimally suited for precise measurements of L‐[ring‐13C6]phenylalanine tracer enrichment in low abundance and in small quantity samples. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

18.
A rapid method for the selective determination of four kinds of tobacco‐specific nitrosamines, N‐nitrosonornicotine, N‐nitrosoanatabine, N‐nitrosoanabasine and 4‐(methylnitrosamino)‐1‐(3‐pyridyl)‐1‐butanone, in mainstream cigarette smoke was developed by GC coupled to positive chemical ionization triple‐quadrupole MS. After mainstream cigarette smoke was collected on a cambridge filter pad, the particulate matter was extracted with 0.1 M HCL aqueous solution, cleaned by positive cation‐exchange solid extraction, and finally injected into GC–MS/MS using isotopically labeled analogues as internal standards. Excellent linearity was obtained over the concentration range of 0.5–200.0 ng mL?1 for all tobacco‐specific nitrosamines with values for correlation coefficient between 0.9996–0.9999. Limits of detection of each tobacco specific nitrosamine varied from 0.023–0.028 ng cig?1, and lower limits of quantification varied from 0.077–0.093 ng cig?1. The recovery of each tobacco specific nitrosamine was from 90.0–109.0%. The relative standard deviations of the intra‐day and inter‐day precisions were 3.1–5.8 and 3.9–6.6, respectively. This method was applied to reference and domestic cigarettes. The result showed that the method was consistent with traditional methods and can be used as an effective approach for the routine analysis of tobacco‐specific nitrosamines.  相似文献   

19.
A simple, rapid and sensitive method for quantification of atomoxetine by liquid chromatography–tandem mass spectrometry (LC‐MS/MS) was developed. This assay represents the first LC‐MS/MS quantification method for atomoxetine utilizing electrospray ionization. Deuterated atomoxetine (d3‐atomoxetine) was adopted as the internal standard. Direct protein precipitation was utilized for sample preparation. This method was validated for both human plasma and in vitro cellular samples. The lower limit of quantification was 3 ng/mL and 10 nm for human plasma and cellular samples, respectively. The calibration curves were linear within the ranges of 3–900 ng/mL and 10 nm to 10 µm for human plasma and cellular samples, respectively (r2 > 0.999). The intra‐ and inter‐day assay accuracy and precision were evaluated using quality control samples at three different concentrations in both human plasma and cellular lysate. Sample run stability, assay selectivity, matrix effect and recovery were also successfully demonstrated. The present assay is superior to previously published LC‐MS and LC‐MS/MS methods in terms of sensitivity or the simplicity of sample preparation. This assay is applicable to the analysis of atomoxetine in both human plasma and in vitro cellular samples. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号