首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A new method of SS-RTP for the determination of trace silver has been established. This method is based on the fact that Ag+, when activated by ,-bipyridyl (bipy) in a media of HAc–NaAc (pH=4.9), can catalyze the reaction of Rhodamine B (RhoB) oxidized by K2S2O8, thus causing the Solid Substrate Room-Temperature Phosphorescence (SS-RTP) of RhoB to be quenched. The activating efficiency of bipy is 6.7 times higher than that of o-phenanthroline (phen). The reduction of the phosphorescence intensity (Ip) of RhoB is directly proportional to the concentration of Ag+ ions in the range of 1.6016.0agspot–1 (0.40µLspot–1). The regression equation of the working curve can be expressed as Ip=18.78+5.100mAg+ (agspot–1) (r=0.9994, n=6), the detection limit is 0.28agspot–1. This rapid, accurate and sensitive method has been successfully applied to the determination of trace silver in tea and human hair samples, and the results agree well with the Atomic Absorption Spectroscopy (AAS) method. The mechanism of the catalyzing reaction is also discussed.  相似文献   

2.
A carbon black microelectrode modified by -MnO2 has been prepared. The electrocatalytical oxidation of ascorbic acid (AA) at this microelectrode was investigated. The 2nd-order linear scan voltammograms of AA are recorded from –0.5 to 0.5V (vs. SCE). The relationship between the oxidation peak current of AA and its concentration in the range of 1.0×10–64.0×10–3molL–1 is linear. The detection limit (3) was found to be 6.0×10–7molL–1. Also, the determination of AA in samples is evaluated, and the results are satisfactory.  相似文献   

3.
A simple and novel electrogenerated chemiluminescence (ECL) method for the determination of sulfite has been developed based on the energy transfer ECL process. It was found that a weak ECL signal of sulfite was electrochemically generated on a platinum electrode in neutral aqueous solution. The signal was strongly enhanced by rhodamine B as an energy receptor and further enhanced by the neutral surfactant Tween 80. In 0.10M phosphate buffer solution (pH=7.5) containing 2.0×10–6gmL–1 rhodamine B and 0.4% (v/v) Tween 80, the ECL response to the concentration of sulfite at a potential of 0.82V was linear over a range of 1.0×10–7gmL–1 to 8.0×10–6gmL–1, and the detection limit was 5×10–8gmL–1. The relative standard deviation (n=11, 1.0×10–6gmL–1) was 3.8%. The proposed method has been successfully applied to the determination of sulfite in pharmaceutical injections and white sugar samples.  相似文献   

4.
A sub-micrometer thin-layer DNA modified carbon fiber microcylinder electrode was prepared by electrodeposition of ct-DNA at 1.5V (vs. Ag/AgCl). The voltammetric behavior of dopamine (3-hydroxytyramine) was investigated at the modified electrode. It was found that the modified electrode exhibits a highly electrocatalytic activity toward dopamine oxidation. Differential pulse voltammetry was used for determination of dopamine in pH 7.4 phosphate buffer solution. A linear response of the peak current versus the concentration was found in the range of 4×10–6 to 10–4molL–1 at 10–4molL–1 AA (ascorbic acid) coexistence (R=0.9959) and the range of 6×10–5 to 10–3molL–1 at 10–3molL–1 AA (R=0.9960). The presence of a high concentration of ascorbic acid did not interfere with the determination. The proposed method exhibited good recovery and reproducibility. This method can be applied to the detection of DA in real samples.  相似文献   

5.
A simple commercial graphite pencil electrode (GPE) was utilized for monitoring caffeine using the square-wave anodic stripping voltammetry (SWASV) method. This method was applied to determine the caffeine levels in several tea samples, which yielded a relative error of 1% in the concentrations. Caffeine was deposited at 0.0V (vs. Ag/AgCl), then reduced at +1.40V to strip it on the GPE. Optimal experimental conditions for the analysis were found to be as follows: pH value of 9 for the medium; deposition potential of 0.0V; deposition time of 120s; SW frequency of 25Hz; SW amplitude of 45mV, and step potential of 6mV. Given these optimum conditions, a linear range was observed within the concentration of 0500mgL–1. At caffeine concentrations of 50.0, 250.0, and 500.0mgL–1, the relative standard deviations in measured concentrations (n=12) were 0.19, 0.09, and 0.11%, respectively. The detection limit was found to be 9.2mgL–1, which is comparable with the result obtained using a carbon paste electrode, equivalent to 8.2mgL–1.  相似文献   

6.
A new method for the simultaneous determination of heavy metal ions in Chinese herbal medicine by microwave digestion and reversed-phase high-performance liquid chromatography (RP-HPLC) has been developed. The Chinese herbal medicine samples were digested by microwave digestion. Lead, cadmium, mercury, nickel, copper, zinc, and tin ions in the digested samples were pre-column derivatized with tetra-(4-chlorophenyl)-porphyrin (T4-CPP) to form the colored chelates which were then enriched by solid phase extraction with C18 cartridge and eluted from the cartridge with tetrahydrofuran (THF). The chelates were separated on a Waters Xterra RP18 column by gradient elution with methanol (containing 0.05molL–1 pyrrolidine-acetic acid buffer salt, pH=10.0) and THF (containing 0.05molL–1 pyrrolidine-acetic acid buffer salt, pH=10.0) as mobile phase at a flow rate of 0.5mLmin–1 and detected with a photodiode array detector in the range of 350–600nm. In the original samples the detection limits of lead, cadmium, mercury, nickel, copper, zinc and tin are 4ngL–1, 3ngL–1, 6ngL–1, 5ngL–1, 2ngL–1, 6ngL–1, and 4ngL–1, respectively. This method was applied to the determination of lead, cadmium, mercury, nickel, copper, zinc and tin in Chinese herbal medicine samples with good results.  相似文献   

7.
A new approach, based on non-aqueous capillary electrophoresis separation and indirect photometric detection, was established for the determination of the transition metal ions Pb2+, Zn2+ and Cd2+. Under optimized conditions, the method produced baseline separation of these three metal ions. The linear range and detection limits were 1050µM, 1.9µM for Cd2+; 1050µM, 2.1µM for Zn2+; and 20100µM, 3.8µM for Pb2+, respectively.  相似文献   

8.
Thallium in natural water samples was determined by electrothermal atomic absorption spectrometry after 1000-fold enrichment by mini solid-phase extraction from a 100-mL sample solution. A Tl-pyrrolidine-1-carbodithioate complex formed in a sample solution of pH 1.6 was extracted on fine particles of a cellulose nitrate resin dispersed in the sample solution. The cellulose nitrate resin was then collected on a membrane filter (25mmø) by filtration under suction using a glass funnel with an effective filtration area of 0.64cm2. As a result, a circular thin layer of the resin phase with a diameter of 9mm was obtained. Then the resin phase was carved out by an acrylate resin puncher with a 10-mmø hole to put it into a sample cup containing 100µL of 10mM HNO3 containing 0.5mM NaCl. The resin phase was suspended in the solution by ultrasonication. 1000-fold enrichment was thus attained within 15min, and the suspension was delivered to electrothermal atomic absorption spectrometry. The linear calibration graph was obtained in the range of 0–4ng of Tl in 100mL of a sample solution. The detection limit obtained by 3 method was 0.19ng. The proposed method was applied to the determination of Tl in natural water samples. The results showed the concentration of Tl in seawater was 12.1±1.8pgmL–1 for the calibration graph method and 12.6±1.4pgmL–1 for the standard addition method. A snowmelt sample contained 20.7±1.0pgmL–1 of Tl.  相似文献   

9.
A microcolumn on-line preconcentration and separation system was developed for the flame atomic absorption spectrometric (FAAS) determination of trace levels of gold and palladium. The analytes were selectively adsorbed onto the microcolumn packed with 2-mercaptothiazole immobilized silica gel (MBTSG) in an acidity range of 0.1 to 6.0M HCl at a sampling flow rate of 4.0mLmin–1. The analytes adsorbed could be desorbed by a thiourea solution with a flow rate of 2.0mLmin–1. Most of the common coexisting metal ions at a concentration of 25.0mgmL–1 and anions at a concentration of 50.0mgmL–1 did not interfere with the preconcentration and determination of Au and Pd. The limits of detection (LOD), defined as three times the standard deviation of the blank (3), of Au and Pd are 10ngmL–1 and 26ngmL–1, respectively, with a preconcentration time of 60s. The relative standard deviation (RSD) is about 2.0% for 0.20µgmL–1 Au and 0.30µgmL–1 Pd. With a sample loading time of 30min, 6.7ngmL–1 Au and 10ngmL–1 Pd can be preconcentrated quantitatively. A geological sample, an anode slime and a secondary nickel alloy were successfully determined with the proposed method, and the results obtained showed good agreement with the certified values.Received December 23, 2002; accepted May 14, 2003 Published online August 8, 2003  相似文献   

10.
The fabrication and electrochemical characteristics of a penicillamine (PCA) self-assembled monolayer modified gold electrode were investigated. The self-assembled electrode shows obvious electrocatalytic activity for the oxidation of epinephrine (EP). In phosphate buffer (pH 7.73), a sensitive oxidation peak was observed at 0.190V with the PCA modified Au electrode. The peak current is proportional to the concentration of EP in the range of 2.0×10–56.0×10–4molL–1 and 5.0×10–6 2.0×10–4molL–1 for cyclic voltammetry (CV) and differential pulse voltammetry (DPV) with the detection limits of 1.8×10–7 and 1.3×10–7molL–1, respectively. The possible reaction mechanism is also discussed. The PCA self-assembled monolayer modified gold electrode is highly stable and can be applied to the determination of EP in practical injection samples. Application is simple, rapid and produces accurate results.  相似文献   

11.
A -mercaptopropionic acid (MPA) self-assembled monolayer modified electrode (MPA/SAM/Au) on a gold electrode has been fabricated. The characterization of the MPA/SAM/Au was investigated using attenuated total reflection-fourier transform infrared (ATR-FTIR) and A.C. impedance. The electrochemical behaviors of p-aminophenol (p-AP) were studied at the MPA/SAM/Au by cyclic voltammetry and semi-derivative voltammetry (SDV) in BR buffer solution. The modified electrode shows excellent electrocatalytic activity for the redox of p-AP and accelerates the electron transfer rate. The diffusion coefficient (D) is 4.55×10–6cm2s–1. The oxidative peak current increases linearly with the concentration of p-AP in the range of 4.0×10–88×10–6molL–1 and 1.0×10–52×10–4molL–1 by square wave voltammetry response, respectively. The detection limit (three times the signal blank/slope) is up to 1.2×10–8molL–1. The modified electrode is able to eliminate the interference of p-benzenediol, o-benzenediol and o-AP at a 40-, 90- or 70-fold concentration of p-AP, and it has been satisfactorily used for the determination of the real sample.  相似文献   

12.
A single-wall carbon nanotubes (SWNT) film coated glassy carbon electrode (GCE) was fabricated for the direct determination of 4-nitrophenol (4-NP). The electrochemical behaviors of 4-NP at the SWNT-film coated GCE were examined. In 0.1M phosphate buffer with a pH of 5.0, 4-NP yields a very sensitive and well-defined reduction peak at the SWNT-modified GCE. It is found that the SWNT film exhibits obvious electrocatalytic activity towards the reduction of 4-NP since it not only increases the reduction peak current but also lowers the reduction overpotential. Based on this, an electrochemical method was proposed for the direct determination of 4-NP. The reduction peak current varies linearly with the concentration of 4-NP ranging from 1×10–8 to 5×10–6M, and the detection limit is 2.5×10–9M after 3min of open-circuit accumulation. The relative standard deviation at 2×10–7M 4-NP was about 6% (n=10), suggesting excellent reproducibility. This new method was successfully employed to determine 4-NP in several lake water samples.  相似文献   

13.
This study aims to investigate the distribution of Na, K, Rb and Cs in human brains (5 individuals, 12 brain parts, mean age: 75 years). Distribution of the trace metals between lipid fraction and brain tissue was investigated in solvent extraction experiments. Determinations were carried out by instrumental neutron activation analysis. The present results show a rather non-homogeneous distribution for Na and a relatively uniform distribution for K, Rb and Cs. The mean concentrations found are 7440µgNag–1 dry weight, 12800µgKg–1, 14µgRbg–1 and 50ngCsg–1. A highly significant positive correlation was found between Rb and Cs. Solvent extraction experiments showed that 19% of Rb and 26% of Cs of the total content is located in lipid fraction.  相似文献   

14.
Nanometer-sized L-cysteine-capped ZnS particles were synthesized by a colloidal aqueous method. The functionalized nanoparticles are water-soluble and suitable for biological applications. In Tris-HCl buffer solution, nucleic acids combine with cysteine-capped nano-ZnS particles by intermolecular forces to form larger nanoparticles. There are two resonance light scattering peaks at 304.5nm and 373.8nm, respectively. The enhanced RLS is related to the concentration of nucleic acids in the range of 0.04 to 1.2µgmL–1 for calf thymus DNA and 0.2 to 1.0µgmL–1 for fish sperm DNA. The detection limits (3) are 19ngmL–1 for calf thymus DNA and 23ngmL–1 for fish sperm DNA, respectively. Four synthetic samples were analyzed satisfactorily.  相似文献   

15.
A novel electroanalytical method for the determination of physcion is described for the first time. Physcion yields an adsorption catalytic voltammetric peak at –0.74V (vs. SCE) in 0.4molL–1 NH4Cl–NH3·H2O buffer solution (pH 10.5) at a carbon paste electrode (CPE). The experimental results indicated that physcion is efficiently accumulated at a CPE by adsorption. In the subsequent potential scan, physcion was reduced to a homologous anthrahydroquinone compound. The compound was then immediately oxidized to physcion by the dissolved oxygen in the solution, and then physcion was again reduced at the CPE. As a result, a cyclic catalytic reaction was established. The second-order derivative peak current is proportional to the physcion concentration in the ranges of 2.0×10–104.0×10–9molL–1 (accumulation 90s) and 4.0×10–92.0×10–8molL–1 (accumulation 60s). The limit of detection is 8×10–11molL–1 (S/N=3) for a 120s accumulation time. The method was applied to the direct determination of physcion in the medicinal plant polygonum multiflorum Thumb with satisfactory results.  相似文献   

16.
A microbial sensor for rapid determination of the concentration of biodegradable pollutants in wastewater has been developed using the salt-tolerant yeast Arxula adeninivorans LS3 immobilized by gel entrapment with poly (carbamoyl) sulfonate hydrogel (PCS gel) on a Clark-type oxygen electrode. This sensor needs 5min for every measurement instead of 5 days for BOD5. The sensor has a linear response of up to 550mgL–1 BOD with a correlation of coefficient R2=0.9785. The detection limit was calculated to be 2.1mgL–1 BOD equivalents, and the determination limit was 6.0mgL–1 BOD equivalents. The high tolerance to salt of the Arxula adeninivorans LS3 strain prevents the inactivation of cells caused by the seawater from affecting the measurements. In a 24-hour comparative study using real wastewater samples from an international college situated in Hong Kong, the microbial sensor showed a very good correlation (R2=0.9134) with the standard BOD5 method and truly reflected the life cycle of the college people. The microbial sensor allows almost ideal real-time monitoring in water pollution and degradation.  相似文献   

17.
The kinetics of formation and dissociation reactions of [Ru(CN)5L]3– with a series of heterocyclic ligands were studied in aqueous media. In this presence of an excess of heterocycle, the observed second order rate constants were calculated from the kobs versus [ligand] plot at =0.100m NaClO4. Activation parameters for the formation reactions (H=28±7kJmol–1 and S=140±35JK–1mol–1) are comparable for all systems, indicating a common mechanism. The kinetics of exchange of coordinated heterocycles for 1,3,5-triazine yielded a rate saturation typical of a limiting dissociative mechanism. Activation parameters of the limiting first order specific rate of dissociation reactions were H=85±7kJmol–1 and S=18±4JK–1mol–1. Equilibrium constants were calculated from the second order rates of formation and pseudo-first order rates of dissociation reaction.  相似文献   

18.
This paper presents a new simple and rapid procedure for the preconcentration and determination of platinum. It is based on the adsorption of the metal ion and preconcentration on a micro-column (3cm×3mm) placed in the injection valve of a flow injection (FI) manifold and packed with 1,5-bis[(2-pyridyl)-3-sulphophenyl-methylene]thiocarbonohydrazide (PSTH) immobilised on an anion-exchange resin (Dowex 1X8-200). The metal was eluted from the column using a solution of 2M HNO3. Various parameters and chemical variables affecting the preconcentration and determination of this metal by ICP-AES were evaluated. Five variables (sample flow rate, eluent flow rate, nebulizer flow rate, buffer concentration and mixing coil length) were considered as factors in the optimisation process. Interactions between analytical factors, and their optimal levels were investigated using two level factorial and central matrix designs. The optimum conditions established were applied to the determination of platinum by flow injection inductively coupled plasma atomic emission spectrometry (FI-ICP-AES). The method has a linear calibration range of 25 to at least 200ngmL–1 with a detection limit of 7.4ngmL–1 (S/N=3) and a throughput of 10 samples h–1 using 5min. preconcentration time. The precision of the method (RSD) was 3.06% ngmL–1 at the 50ngmL–1 level of Pt(IV) and 2.93% at the 150ngmL–1 level. The accuracy of the method was examined by determining the analyte content in spiked waters and by analysing an automobile catalyst standard reference material. The results show good agreement with the certified value and sufficiently high recoveries.  相似文献   

19.
A photochemical chemiluminescence (CL) method for the determination of lomefloxacin (LFX) is proposed. LFX undergoes a photochemical reaction when irradiated with ultraviolet light, and a complex is formed when the photoproduct reacts with terbium(III), which can greatly enhance the CL of the Ce4+–Na2SO3 system. Under optimum experimental conditions, the linear range is between 9.0×10–10 and 1.0×10–5M, and the detection limit is 2.2×10–10M. The relative standard deviation for the determination of 5.0×10–8M LFX was 3.0% (n=11). The method has been successfully applied to the determination of LFX in dosage form, serum samples and urine samples. The recoveries were 97.9–102.3% for serum and urine samples. The possible mechanism is presented.  相似文献   

20.
A sensitive chemiluminescence method for the determination of acetylspiramycin is presented. It is based on the greatly enhancive effect of acetylspiramycin on the chemiluminescence reaction between luminol and hydrogen peroxide in the flow system. The increase in chemiluminescence intensity was linearly proportional to the acetylspiramycin concentration in the range from 10pg·mL–1 to 2.0ng·mL–1 (r2=0.9979). The detection limit was 3pg·mL–1 (3). At a flow rate of 2.0mL·min–1, the process of determination, including sampling and washing, could be performed in 0.5 min, and the relative standard deviations of seven replicates are less than 5.0%. The proposed method was applied successfully to the determination of acetylspiramycin in pharmaceutical preparations, human urine and serum without pre-treatment. It was found that the excretive ratio of acetylspiramycin reached its maximum 2.0 hours after having been administered orally, and the excretive ratio in 12.0 hours was 8.4.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号