1.
Prostanoids are potent mediators of many physiological and pathophysiological processes. Of the many analytical methodologies used for their qualitative and quantitative analysis, electrospray tandem mass spectrometry coupled to liquid chromatography (LC/ESI-MS/MS) offers a rapid, sensitive and versatile system applicable to lipidomic analyses. We have developed an LC/ESI-MS/MS assay for twenty-seven mediators including prostaglandins, prostacyclines, thromboxanes, dihydroprostaglandins and isoprostanes. The assay was liner over the concentration range 1-100 pg/microL. The limits of detection and quantitation were 0.5-50 and 2-100 pg, respectively, whilst recoveries were from 83-116% depending on the metabolite. The assay can be applied to the profiling of prostanoids produced by a variety of biological fluids and extracts including brain, liver, plasma and urine, thus facilitating our understanding of the role of these lipid mediators in health and disease, as well as assisting in drug development.  相似文献   

2.
Lipases and esterases are important catalysts with wide varieties of industrial applications. Although many methods have been established for detecting their activities, a simple and sensitive approach for picogram detection of lipolytic enzyme quantity is still highly desirable. Here we report a lipase detection assay which is 1000-fold more sensitive than previously reported methods. Our assay enables the detection of as low as 5 pg and 180 pg of lipolytic activity by direct spotting and zymography, respectively. Furthermore, we demonstrated that the detection sensitivity was adjustable by varying the buffering capacity, which allows for screening of both high and low abundance lipolytic enzymes. Coupled with liquid chromatography-mass spectrometry, our method provides a useful tool for sensitive detection and identification of lipolytic enzymes.  相似文献   

3.
A radioimmunoassay procedure to measure estradiol levels in human serum was developed using125I labeled estradiol and antiestradiol antibody raised in-house using the estradiol-6-CMO-BSA as the immunogen. Controlled process serum was used to maintain the serum matrix and sample-standard identity. The assay was validated by analysing several (n=40) samples and comparing with established commercial assays. The assay had a sensitivity of 35 pg/mL and a range of 50 pg/mL to 5 ng/mL. The interassay C.V. were between 2 to 10% while the intraassay C.V. were between 2 and 8%. This assay is sensitive enough for monitoring ovulation and hypersecretions in ovarian tumours and was primarily developed to be used as an in-house assay in the local hospitals.  相似文献   

4.
A simple, selective and very sensitive assay is described for the quantification of physostigmine in blood, plasma and urine. The most appropriate solid phase column was selected after a systematic investigation of nine types of phase. The conditions for solid phase extraction were optimized using [3H]physostigmine so that the overall recoveries were greater than 90%. Physostigmine was retained on alkaline treated cyanopropyl columns and eluted into the minimum volume of methanol, obviating the need for an evaporation step. Extracted samples were quantified by HPLC with a three electrode coulometric detection system. The limit of detection was 50 pg/mL for a 0.5 mL plasma sample. The precision (CV) for 0.5 mL plasma samples containing 50 pg was 8.1%. Application of the method to plasma, blood and urine samples is presented.  相似文献   

5.
A rapid and sensitive LC/MS/MS assay was developed and validated for the determination of clopidogrel in human plasma. Clopidogrel was extracted by single liquid-liquid extraction with pentane, and chromatographic separations were achieved on a C(18) column. The method was validated to demonstrate the specificity, linearity, recovery, lower limit of quantification (LLOQ), stability, accuracy and precision. The multiple reaction monitoring was based on m/z transition of 322.2 --> 211.9 for clopidogrel and 264.1 --> 125.1 for ticlopidine (internal standard). The total analytical run time was relatively short (3 min), and the LLOQ was 10 pg/mL using 0.5 mL of human plasma. The assay was linear over a concentration range from 10 to 10,000 pg/mL (r > 0.999). The intra- and inter-day accuracies were 101.3-108.8 and 98.4-103.5%, respectively, and the intra- and inter-day assay precisions were 1.9-5.5 and 4.4-8.1%, respectively. The developed assay method was applied to a pharmacokinetic study in human volunteers after oral administration of clopidogrel at a dose of 150 mg.  相似文献   

6.
A highly sensitive assay for tyrosine hydroxylase (TH) activity by high-performance liquid chromatography (HPLC) with amperometric detection was devised based on the rapid isolation of enzymatically formed DOPA by a double-column procedure, the columns fitted together sequentially (the top column of Amberlite CG-50 and the bottom column of aluminium oxide). DOPA was adsorbed on the second aluminium oxide column, then eluted with 0.5 M hydrochloric acid, and assayed by HPLC with amperometric detection. D-Tyrosine was used for the control. alpha-Methyldopa was added to the incubation mixture as an internal standard after incubation. This assay was more sensitive than radioassays and 5 pmol of DOPA formed enzymatically could be measured in the presence of saturating concentrations of tyrosine and 6-methyltetrahydropterin. The TH activity in 2 mg of human putamen could be easily measured, and this method was found to be particularly suitable for the assay of TH activity in a small number of nuclei from animal and human brain.  相似文献   

7.
A sensitive electrochemical enzyme-linked immunosorbent assay (ELISA) has been used for the detection of 17beta-estradiol in waste waters. The activity of the label enzyme (horseradish peroxidase) was measured electrochemically using 3,3',5,5'-tetramethylbenzidine as electrochemical substrate. The detection limit was estimated to be 5 pg mL(-1), interday and intraday precision (RSD), ranged from 1 to 3% and from 3 to 6%, respectively. Analysis of waste waters from three different treatment plants demonstrated no matrix effect both for samples diluted 1:1 in buffer and diethyl ether extracted. Data on 36 samples analysed by an LC-ESI-MS-MS procedure and by the electrochemical ELISA assay were compared. Results correlated well. The electrochemical enzyme immunoassay appears suitable as a screening tool for analysis of estradiol in waste waters.  相似文献   

8.
A selective and sensitive assay of substrates (hypoxanthine, xanthine and allopurinol) of xanthine oxidase by reversed-phase liquid chromatography coupled with the use of immobilized enzyme reactors is described. These compounds were oxidized by immobilized xanthine oxidase and produced hydrogen peroxide, which was determined fluorometrically using immobilized peroxidase and p-hydroxyphenylacetic acid. The detection limits of hypoxanthine, xanthine and allopurinol were approximately 50, 120 and 130 pg per injection, respectively. Immobilized xanthine oxidase inhibited by oxipurinol during the assay was reactivated by 2,6-dichlorophenolindophenol and could be used for a long period without a significant activity loss. These methods were applied to plasma and urine samples.  相似文献   

9.
In this study, we described a pH ELISA using synthetic melanin nanoparticles (SMNPs) for the co-immobilization of glucose oxidase and second antibody as signal labels, portable pH meter as signal readout device for detecting biomarker of myocardial injury. This assay is easy-to-use, portable, sensitive and able to realize point-of-care testing (POCT), which was demonstrated the signifi cant promising in the early diagnosis and screening of acute myocardial infarction.  相似文献   

10.
A sensitive (50 pg/ml) method for the determination of heptylphysostigmine in human plasma is described. The procedure is based on liquid-liquid extraction of the drug from buffered plasma, and analysis of the concentrated organic extract using high-performance liquid chromatography on a silica column, under normal-phase chromatographic conditions, with fluorescence detection. Physostigmine was used as an internal standard. The assay has been fully validated in the concentration range 50-2000 pg/ml and utilized for the analysis of clinical samples from subjects dosed with heptylphysostigmine.  相似文献   

11.
Thin-layer chromatography (TLC) was used to screen for acetylcholinesterase inhibitors from Amaryllidaceae extracts. The TLC plate was developed and then stained using Ellman's reagent, 5,5'-dithiobis-(2-nitrobenzoic acid), to detect acetylcholinesterase activity. The advantages of this TLC assay method were that we could dereplicate the known inhibitor galanthamine, widely occurring in Amaryllidaceae, at an early stage of the isolation procedure. Moreover, there is no disturbance from sample dissolving solvents as in the microplate assay, and it is a very simple method. The detection limits were 10-200 ng for several known acetylcholinesterase inhibitors tested, and it is thus more sensitive than UV or Dragendorff's reagent detection. Also the minimal detectable amount for an acetylcholinesterase inhibitor tested was much less than that needed for the microplate assay. We screened 15 Amaryllidaceae extracts using this TLC method, and chose candidates for acetylcholinesterase inhibitor isolation.  相似文献   

12.
Grastim is bacterially produced recombinant counterpart of human granulocyte colony stimulating factor (G-CSF). It has biological activity similar to that of endogenous G-CSF. In the present work a sensitive, accurate, precise and enzyme-linked immunosorbent assay (ELISA) for the quantitation of G-CSF in rat plasma was developed and validated. The ELISA method employed a technique in which anti-human-G-CSF was adsorbed onto 96-well maxisorp plates and used to capture the G-CSF in rat plasma samples. The captured G-CSF was then detected using streptavidin-HRP amplification system. Absolute recovery was >90% from rat plasma. The validation includes assessments of method accuracy and precision, range of reliable response, lower limit of quantitation (LLOQ), storage stability (30 days) in rat plasma and assay specificity. The standard curve for G-CSF was linear (R2 > 0.996) in the concentration range 4.88-625 pg/mL. The LLOQ was established at 4.88 pg/mL. The inter- and intra-day precisions in the measurement of quality control (QC) samples, 15, 250 and 500 pg/mL, were in the range 3.00-8.66% relative standard deviation (RSD) and 1.03-4.69% RSD, respectively. Accuracy in the measurement of QC samples was in the range 87.28-110.79% of the nominal values. The assay shows dilutional linearity and specificity. Stability of G-CSF was established for 30 days at -80 degrees C and through three freeze-thaw cycles. The validated assay was successfully employed for the assessment of pharmacokinetic disposition of G-CSF in rats.  相似文献   

13.
A sensitive radioenzymaticc--thin-layer chromatographic assay for the quantitative analysis of the tetrahydroisoquinoline alkaloid, salsolinol, in plasma and neonatal rat tissue is described. The assay involves the enzymatic O-methylation of salsolinol by catechol-O-methyltransferase in presence of [3H]S-adenosylmethionine, and subsequent separation by thin-layer chromatography of the resultant [3H]O-methyl-salsolinol from the O-methylated derivatives of dopamine, epinephrine and norepinephrine. The method allows the detection of as little as 100 pg salsolinol per g tissue, and the accurate quantitation of as little as 100 pg/ml plasma and 500 pg/g tissue. This assay permitted the detection of trace amounts of endogenous salsolinol in neonatal rat tissue (less than 500 pg/g tissue).  相似文献   

14.
We developed and validated an on-line reverse-phase two-dimensional LC/MS/MS (2D-LC/MS/MS) system for simultaneous determination of the levels of prostaglandin (PG) E(2) as well as PGF(2alpha) and its metabolite 13,14-dihydro-15-keto PGF(2alpha) (F(2alpha)-M) in human plasma. Analytes were extracted by a three-step solid-phase extraction. Samples were then analyzed by on-line 2D-LC/MS/MS with electrospray ionization in negative mode. The 2D-LC system is composed of two reverse-phase analytical columns with a trapping column linking the two analytical columns. While an acidic buffer was used for both separation dimensions, differing organic solvents were employed for each dimension: methanol for the first and acetonitrile for the second to increase resolving power. The 2D-LC/MS/MS method was highly selective and sensitive with a significantly lower limit of quantitation (0.5 pg/mL for PGE(2) and 2.5 pg/mL for PGF(2alpha) and F(2alpha)-M, respectively). Linearity of the 2D-LC/MS/MS system was demonstrated for the calibration ranges of 0.5-50 pg/mL for PGE(2) and 2.5-500 pg/mL for PGF(2alpha) and F(2alpha)-M, respectively. Acceptable precision and accuracy were obtained throughout the calibration curve ranges. This highly selective and sensitive method was successfully utilized to determine the endogenous levels of PGE(2), PGF(2alpha), and F(2alpha)-M in plasma samples from six (four male and two female) normal volunteers. The mean concentrations for each analyte were 0.755 pg/mL for PGE(2), 5.70 pg/mL for PGF(2alpha) and 9.48 pg/mL for F(2alpha)-M.  相似文献   

15.
A sensitive and selective gas chromatographic assay method employing splitless injection, fused-silica capillary columns and electron-capture detection is reported for the quantitation of the tocolytic drug, ritodrine, in a variety of biological fluids obtained from the pregnant ewe and fetus. This method has improved sensitivity and selectivity over previously published assay procedures. A 25 m x 0.31 mm I.D., cross-linked 5% phenylmethylsilicone, fused-silica capillary column was employed for all analyses. Linearity of response was observed over the range 2.5-75 ng of ritodrine base per 0.05-0.5 ml of biological fluid, representing approximately 1-75 pg at the detector. The coefficient of variation was less than 10% over the range 2.5-75 ng of added ritodrine. The minimum quantifiable amount is approximately 2.5 ng from a 0.5-ml biological fluid sample. Applicability of this method to biological fluids, obtained from ovine subjects, is demonstrated by the analysis of samples obtained during the course of ritodrine placental transfer studies.  相似文献   

16.
A specific in vitro assay was developed for the protein carboxyl methyltransferase that is involved in the chemotactic behavior of Salmonella typhimurium. This cytosolic enzyme catalyzes an S-adenosyl-L-methionine-dependent methyl esterification of glutamyl residues on a class of 60,000-dalton inner-membrane proteins. The activity was found to display a pH optimum of 6.5 and be sensitive to the concentration of salts in the assay medium. No detectable activity was found towards a variety of other proteins which serve as substrates for mammalian and other bacterial carboxyl methyltransferases. This assay was used to quantitate the methylation of the 60,000-dalton methyl-accepting proteins in response to chemoeffectors. Small but reproducible concentration-dependent changes in the initial rates of in vitro methylation were observed with chemotactic attractants and repellents. The specific methyltransferase activity was found to be absent in several mutants in flagellar synthesis (fla-), suggesting that the synthesis of this enzyme is coordinately regulated with that of flagellin and basal bodies. The hydrodynamic properties of the enzyme in crude extracts were determined by gel filtration and sucrose velocity gradient centrifugation, and a native molecular weight of 41,000 was calculated from these data.  相似文献   

17.
Complete separation of the TMS derivatives of histamine, 1-methyl histamine and 3-methyl histamine was achieved in two minutes in a 7 m × 0.25 mm column coated with SP 2250. Using NPD, histamine was detectable at levels as low as 20 pg. This offers a rapid, sensitive procedure with potential for clinical diagnosis and food analysis.  相似文献   

18.
A high-performance liquid chromatography assay for activity of 1-deoxy-D-xylulose 5-phosphate synthase, an early enzyme in the recently discovered 2-C-methyl-D-erythritol-4-phosphate pathway, was developed. In this assay, the enzymatic product 1-deoxy-D-xylulose was first derivatized with a fluorescent reagent 2-anthranilic acid, followed by separation using HPLC on a Nova-Pak phenyl column with a mobile phase containing CH3CN-water-1-butylamine-tetrahydrofuran-H3PO4 (2:97:0.125:0.5:0.25, v/v). The eluate was monitored by fluorescence detection at an excitation wavelength of 320 nm and an emission wavelength of 425 nm for quantitation of the fluorescent derivative. A linear response was obtained between 5 and 200 ng of 1-deoxy-D-xylulose. This assay was successfully applied to measure the 1-deoxy-D-xylulose 5-phosphate synthase activity in a recombinant E. coli overexpressing dxs gene. It demonstrated that this assay is simple, sensitive and selective compared to the methods used at present.  相似文献   

19.
MutS, a protein involved in DNA mismatch repair, recognizes mispaired and unpaired bases in duplex DNA. We have previously used MutS in an electrochemical double-surface technique (DST) for in-vitro detection of point mutations in DNA. The DST involved binding of unlabeled MutS to DNA heteroduplexes at the surface of magnetic beads followed by a highly sensitive electrochemical determination of the protein by measurement of a catalytic protein signal (peak H) at mercury electrodes. Detection of MutS using a peak resulting from oxidation of tyrosine and tryptophan residues of the protein at a carbon-paste electrode (CPE) was also possible but was approximately three orders of magnitude less sensitive. In this work we present an optimized technique for ex-situ voltammetric determination of MutS at a CPE. Choice of optimum experimental conditions (pH of supporting electrolyte, square-wave voltammetry settings, etc.) resulted in substantial improvement of the sensitivity of the assay, enabling detection of approximately 140 pg (1.6 fmol protein monomer) MutS in a 5-μL sample. The sensitivity was increased further by acid hydrolysis of the protein before measurement. The hydrolyzed protein was detectable down to 5 pg (approx. 56 amol) MutS in 5 μL solution. By using the DST combined with determination of the bound unlabeled MutS at the CPE we demonstrated selective interactions of the protein with single-base mismatches and discrimination among different base mispairs in 30-mer or 95-mer DNA duplexes. In agreement with previous studies, binding of the protein to the 30-mer substrates followed the trend G:T>>C:A>A:A>C:T>homoduplex. The electrochemical data were confirmed by use of an independent technique—a quartz-crystal microbalance for real-time monitoring of MutS interactions with DNA duplexes containing different base mispairs. By using the electrochemical DST a G:T mismatch was detectable in up to 1000-fold excess of homoduplex DNA.  相似文献   

20.
Reactive nitrogen species such as peroxynitrite can nitrate specific amino acids, whether free or protein bound, and 3-nitrotyrosine is believed to be one marker of this reaction. To examine the significance of this pathway in biological systems we have developed an accurate, sensitive, and specific assay for 3-nitrotyrosine based on combined liquid chromatography tandem mass spectrometry. Our approach allowed simultaneous analysis of both tyrosine and 3-nitrotyrosine and employs isotopomer standards (i.e., [15N1, 13C9]-tyrosine and [13C6]-3nitrotyrosine). Calibration curves were linear (r2 = 0.999) across the range 0.5-100 pg/microL (i.e., 2.2-442 fmol/microL), and the detection limit for standard samples was 0.5 pg/microL (2.2 fmol/microL, or 10 fmol on column; S/N = 5) or 1 pg/microL (4.4 fmol/microL) for extracted (biological) samples. As a component of this study we have undertaken an extensive investigation of artifactual formation of 3-nitrotyrosine under conditions that exist during sample extraction and derivatization. Our studies show that under appropriate conditions (low pH, elevated temperatures, and in the presence of a vast excess of the two substrates, tyrosine and the nitrate anion), 3-nitrotyrosine can readily be formed as an artifact.  相似文献   