首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 546 毫秒
1.
We report a new fast method for the simultaneous determination of amoxicillin, clavulanate, and potassium by capillary electrophoresis with capacitively coupled contactless conductivity detection. Samples containing potassium as the cation, and both amoxicillin and clavulanate as anions were determined simultaneously in a single run (in less than 45 s) using 10 mmol/L of both 2‐amino‐2‐hydroxymethyl‐propane‐1,3‐diol and 3‐{[2‐hydroxy‐1,1‐bis(hydroxymethyl)ethyl]amino}‐1‐propanesulfonic acid (pH 8.4) as the background electrolyte. Limits of detection were 25.0, 5.0, and 4.0 μmol/L for amoxicillin, clavulanate, and potassium, respectively. The proposed method is inexpensive, simple, fast (75 injections h−1), environment friendly (minimal waste generation), and accurate (recovery values between 98 and 103%). The results obtained with the proposed method were statistically similar (95% confidence level) to those obtained by using high‐performance liquid chromatography (amoxicillin and clavulanate) and flame photometry (potassium).  相似文献   

2.
A flow system exploiting the multicommutation approach is proposed for spectrophotometric determination of tannin in beverages. The procedure is based on the reduction of Cu(II) in the presence of 4,4′-dicarboxy-2,2′-biquinoline, yielding a complex with maximum absorption at 558 nm. Calibration graph was linear (r = 0.999) for tannic acid concentrations up to 5.00 μmol L− 1. The detection limit and coefficient of variation were estimated as 10 nmol L− 1 (99.7% confidence level) and 1% (1.78 μmol L− 1 tannic acid, n = 10), respectively. The sampling rate was 50 determinations per hour. The proposed procedure is more sensitive and selective than the official Folin-Denis method, also minimizing drastically waste generation. Recoveries within 91.8 and 115% were estimated for total tannin determination in tea and wine samples.  相似文献   

3.
《Electrophoresis》2017,38(13-14):1800-1805
Fast, simple, and accurate CE method enabling determination of lipoic acid (LA) in human urine has been developed and validated. LA is a disulfide‐containing natural compound absorbed from the organism's diet. Due to powerful antioxidant activity, LA has been used for prevention and treatment of various diseases and disorders, e.g. cardiovascular diseases, neurodegenerative disorders, and cancer. The proposed analytical procedure consists of liquid–liquid sample extraction, reduction of LA with tris(2‐carboxyethyl)phosphine, derivatization with 1‐benzyl‐2‐chloropyridinium bromide (BCPB) followed by field amplified sample injection stacking, capillary zone electrophoresis separation, and ultraviolet‐absorbance detection of LA‐BCPB derivative at 322 nm. Effective baseline electrophoretic separation was achieved within 6 min under the separation voltage of 20 kV (∼80 μA) using a standard fused‐silica capillary (effective length 51.5 cm, 75 μm id) and BGE consisted of 0.05 mol/L borate buffer adjusted to pH 9. The experimentally determined limit of detection for LA in urine was 1.2 μmol/L. The calibration curve obtained for LA in urine showed linearity in the range 2.5–80 μmol/L, with R 2 0.9998. The relative standard deviation of the points of the calibration curve was lower than 10%. The analytical procedure was successfully applied to analysis of real urine samples from seven healthy volunteers who received single 100 mg dose of LA.  相似文献   

4.
A new luminescent europium probe is presented for the determination of phosphate (P) in microtiter plate format. The assay is based on the quenching of the luminescence of the europium-tetracycline (EuTc) 1:1 complex by phosphate using a reagent concentration of 20.8 μmol/L. The probe is excited at 400 nm and displays a large Stokes’ shift of 210 nm. The emission maximum is located at 616 nm. The system works best at neutral pH 7 and is therefore suitable for phosphate determination in biological and biochemical systems. The linear range of the calibration plot is from 5 × 10−6 mol/L to 7.5 × 10−4 mol/L of phosphate, and the limit of detection is 3 μmol/L.  相似文献   

5.
A modified dispersive liquid phase microextraction based on sequential injection solidified floating organic drop was developed for simultaneous separation/preconcentration of trace amounts of phenobarbital and phenytoin. The important factors affecting on the extraction recovery including pH, the volume of extraction solvent, ionic strength, and the number of injections were investigated and optimized by Box–Behnken design and desirability function. Under the optimum experimental conditions, the calibration graph was linear in the concentration range of 1.0–300.0 μg/L (r= 0.997) for phenobarbital and 2.0–400.0 μg/L (r= 0.996) for phenytoin. The limit of detection and limit of quantification were 0.35 and 1.2 μg/L for phenobarbital and 0.65 and 2.2 μg/L for phenytoin, respectively. The relative standard deviation for six replicate determinations at 10 μg/L was 3.3 and 4.1% for phenobarbital and phenytoin, respectively. The developed method was successfully applied to the determination of phenobarbital and phenytoin in urine and plasma samples.  相似文献   

6.
This study aims at developing a novel, sensitive, fast, simple and convenient method for separation and preconcentration of trace amounts of fluoxetine before its spectrophotometric determination. The method is based on combination of magnetic mixed hemimicelles solid phase extraction and dispersive micro solid phase extraction using 1-hexadecyl-3-methylimidazolium bromide coated magnetic graphene as a sorbent. The magnetic graphene was synthesized by a simple coprecipitation method and characterized by X-ray diffraction (XRD), Fourier transform infrared (FT-IR) spectroscopy and scanning electron microscopy (SEM). The retained analyte was eluted using a 100 μL mixture of methanol/acetic acid (9:1) and converted into fluoxetine-β-cyclodextrin inclusion complex. The analyte was then quantified by fiber optic linear array spectrophotometry as well as mode-mismatched thermal lens spectroscopy (TLS). The factors affecting the separation, preconcentration and determination of fluoxetine were investigated and optimized. With a 50 mL sample and under optimized conditions using the spectrophotometry technique, the method exhibited a linear dynamic range of 0.4–60.0 μg L−1, a detection limit of 0.21 μg L−1, an enrichment factor of 167, and a relative standard deviation of 2.1% and 3.8% (n = 6) at 60 μg L−1 level of fluoxetine for intra- and inter-day analyses, respectively. However, with thermal lens spectrometry and a sample volume of 10 mL, the method exhibited a linear dynamic range of 0.05–300 μg L−1, a detection limit of 0.016 μg L−1 and a relative standard deviation of 3.8% and 5.6% (n = 6) at 60 μg L−1 level of fluoxetine for intra- and inter-day analyses, respectively. The method was successfully applied to determine fluoxetine in pharmaceutical formulation, human urine and environmental water samples.  相似文献   

7.
An approach involving ion‐pair switchable‐hydrophilicity solvent‐based homogeneous liquid–liquid microextraction coupled to high‐performance liquid chromatography has been applied for the preconcentration and separation of paraquat in a real sample. A mixture of triethylamine and water was used as the switchable‐hydrophilicity solvent. The pH was regulated using carbon dioxide; hence the ratio of the ionized and non‐ionized form of triethylamine could control the optimum conditions. Sodium dodecyl sulfate was utilized as an ion‐pairing agent. The ion‐associate complex formed between the cationic paraquat and sodium dodecyl sulfate was extracted into triethylamine. The separation of the two phases was carried out by the addition of sodium hydroxide, which changed the ionization state of triethylamine. The effects of some important parameters on the extraction recovery were investigated. Under the optimum conditions (500 μL of the extraction solvent, 1 mg sodium dodecyl sulfate, 2.0 mL of 10 mol/L sodium hydroxide, and pH 4), the limit of detection and the limit of quantification were 0.2 and 0.5 μg/L, respectively, with preconcentration factor of 74. The precision (RSD, n  = 10) was  <5%. The recovery of the analyte in environmental and biological samples was in the range of 90.0–92.3%.  相似文献   

8.
Wenhua Huang  Ning Xu 《合成通讯》2016,46(14):1182-1186
1-Substituted 2,6,7-trioxa-4-phospha-1-borabicyclo[2.2.2]octan-1-uides were obtained in 31–71% yields by the reaction of tetrakis(hydroxymethyl)phosphonium sulfate with alkyl- or arylboronic acids in the presence of tetrabutylammonium hydroxide.  相似文献   

9.
A new method involving headspace single-drop microextraction (SDME) and capillary electrophoresis (CE) is developed for the preconcentration and determination of ammonia (as dissolved NH3 and ammonium ion). An aqueous microdrop (5 μL) containing 1 mmol/L H3PO4 and 0.5 mmol/L KH2PO4 (as internal standard) was used as the acceptor phase. Common experimental parameters (sample and acceptor phase pH, extraction temperature, extraction time) affecting the extraction efficiency were investigated. Proposed SDME-CE method provided about 14-fold enrichment in about 20 min. The calibration curve was linear for concentrations of NH4+ in the range from 5 to 100 μmol/L (R2 = 0.996). The LOD (S / N = 3) was estimated to be 1.5 μmol/L of NH4+. Such detection sensitivity is high enough for ammonia determination in common environmental and biological samples. Finally, headspace SDME was applied to determine ammonia in human blood, seawater and milk samples with spiked recoveries in the range of 96-107%.  相似文献   

10.
A rapid analytical method was developed for the determination of 4‐methylimidazole from red ginseng products containing caramel colors by using dispersive liquid–liquid microextraction with in situ derivatization followed by gas chromatography with mass spectrometry. Chloroform and acetonitrile were selected as the extraction and dispersive solvents, and based on the extraction efficiency, their optimum volumes were 200 and 100 μL, respectively. The optimum volumes of the derivatizing agent (isobutyl chloroformate) and catalyst (pyridine), pH, and concentration of NaCl in the sample solution were determined to be 25 and 100 μL, pH 7.6, and 0% w/v, respectively. Validation of the optimized method showed good linearity (R2 > 0.999), accuracy (≥89.86%), intra‐ (≤6.70%) and interday (≤4.17%) repeatability, limit of detection (0.96 μg/L), and limit of quantification (5.79 μg/L). The validated method was applied to quantify 4‐methylimidazole in red ginseng juices and concentrates, 4‐methylimidazole was only found in red ginseng juices containing caramel colorant (42.91–2863.4 μg/L) and detected in red ginseng concentrates containing >1% caramel colorant.  相似文献   

11.
Gold nanoparticles/carbon nanotubes (Au-NPs/CNTs) composites were rapidly synthesized by microwave radiation, and firstly applied for the determination of trace mercury(II) by anodic stripping voltammetry (ASV). The structure and composition of the synthesized Au-NPs/CNTs nanocomposites were characterized by transmission electron microscopy (TEM), energy dispersive X-ray spectroscopy (EDX), UV–vis absorption spectroscopy and cyclic voltammetry. Au-NPs/CNTs nanocomposites modified glassy carbon electrode (Au-NPs/CNTs/GCE) exhibited excellent performance for Hg(II) analysis. A wide linear range (5 × 10−10–1.25 × 10−6 mol/L) and good repeatability (relative standard deviation of 1.84%) were obtained for Hg(II) detection. The limit of detection was found to be 3 × 10−10 mol/L (0.06 μg/L) at 2 min accumulation, while the World Health Organization’s guideline value of mercury for drinking water is 1 μg/L, suggesting the proposed method may have practical utility.  相似文献   

12.
Liang AH  Zhou SM  Jiang ZL 《Talanta》2006,70(2):444-448
Based on resonance scattering (RS) effect of rhodamine dye association particles, a new resonance scattering method for the determination of hydroxyl free radical from Fenton reaction was developed. In HCl-NaAc buffer solution, the OH of Fenton reaction oxidized the excess I to I3. The I3 combined, respectively, with rhodamine B (RhB), butyl rhodamine B (b-RhB), rhodamine 6G (RhG) and rhodamine S (RhS) to form association particles that exhibit stronger resonance scattering effect at 420 nm and 610 nm. However, the RS peak at about 610 nm was interfered with its synchronous fluorescence peak at 580 nm for RhB, 580 nm for b-RhB, 560 nm for RhG and 560 nm for RhS, respectively. The concentration of H2O2 in the range of 0.648-21.6 μmol/L, 0.423-13.0 μmol/L, 0.216-13.0 μmol/L and 0.092-13.0 μmol/L was linear to its resonance scattering intensity at 420 nm. Its detection limit was 0.15 μmol/L, 0.10 μmol/L, 0.092 μmol/L and 0.044 μmol/L, H2O2, respectively. This RhS RS method was applied to selection of the antioxidant, with satisfactory results.  相似文献   

13.
This paper presents a method for fast and simultaneous determination of diclofenac (DCF) and its common counter‐ions (potassium, sodium, and diethylammonium) using CE with capacitively coupled contactless conductivity detection (CE‐C4D). On the basis of a single electropherogram (about 50 s), the proposed method allows the determination of the stoichiometry, absolute quantification and evaluation of the degradation degree of the active pharmaceutical ingredient (DCF). A linear working range from 100 to 500 μmol/L was obtained for all analytes in an equimolar TRIS/TAPS (10 mmol/L) solution as the background electrolyte as well as adequate LOD (7, 6, 7, and 10 μmol/L for K+, Na+, diethylammonium, and DCF, respectively). The proposed method was applied to the analysis of pharmaceutical formulations (tablets and spray form) with similar results to those achieved by HPLC (DCF) or flame photometry (K and Na) at a 95% confidence level.  相似文献   

14.
A novel, highly sensitive, simple, and rapid strategy was designed and developed for simultaneous determination of cabozantinib (CBZ) as an anticancer agent and its main metabolites including monohydroxy sulfate (EXEL-1646), N-oxide (EXEL-5162(, amide cleavage product (EXEL-5366), and 6-desmethyl amide cleavage product sulfate) EXEL-1644). Measurements were done through a micellar liquid chromatography (MLC) method coupled with fluorescence detection. The high-performance liquid chromatography (HPLC) was performed using a Kinetex C18 100 Å column as well as acetonitrile, cetyltrimethylammonium bromide (CTAB; 0.2 mol.L?1), and tris buffer (pH 8.5) solutions as the mobile phase at a 40:50:10 (v/v) ratio. The method’s linearity (20 to 700 ng.mL?1), limit of detection (LOD; 2.11 to 3.69 ng.mL?1), limit of quantification (LOQ; 20 to 30 ng.mL?1), intra- and inter-day precisions (RSD < 4.00%), selectivity, recovery, and robustness were fully evaluated. According to the obtained results, the developed method can be used for simple and rapid (~35 min) quantification of CBZ as an anticancer drug and its major metabolites in human serum samples with high sensitivity and low cost.  相似文献   

15.
A method based on ultrasound‐assisted liquid–liquid extraction and high‐performance liquid chromatography has been optimized for the determination of six polybrominated diphenyl ether congeners. The optimal condition relevant to the extraction was first investigated, more than 98.7 ± 0.7% recovery was achieved with dichloromethane as extractant, 5 min extraction time, and three cycles of ultrasound‐assisted liquid–liquid extraction. Then multiple function was employed to optimize polybrominated diphenyl ether detection conditions with overall resolution and chromatography signal area as the responses. The condition chosen in this experiment was methanol/water 93:7 v/v, flow rate 0.80 mL/min, column temperature 30.0°C. The optimized technique revealed good linearity (R2 > 0.9962 over a concentration range of 1–100 μg/L) and repeatability (relative standard deviation < 6.3%). Furthermore, the detection limit (S/N = 3) of the method were ranged from 0.02 to 0.13 μg/L and the quantification limit (S/N = 10) ranged from 0.07 to 0.35 μg/L. Finally, the proposed method was applied to spiked samples and satisfactory results were achieved. These results indicate that ultrasound‐assisted liquid–liquid extraction coupled with high‐performance liquid chromatography was effective to identify and quantify the complex polybrominated diphenyl ethers in effluent samples.  相似文献   

16.
A simple, rapid, sensitive and accurate spectrophotometric method for the determination of captopril in pure form and pharmaceutical formulations is developed. The procedure is based on the reaction of copper(II) with captopril in the presence of neocuproine (NC) (2,9-dimethyl-1,10-phenanthroline) reagent in acetate buffer at pH 5.0. Copper(II) is reduced easily by captopril to Cu(I)–neocuproine complex, which shows an absorption maximum at 448 nm. Beer’s law was obeyed in the concentration range 0.3–3.0 μg mL?1 with a minimum detection limit (LOD) of 0.039 μg mL?1 and a quantification limit (LOQ) of 0.129 μg mL?1. For more accurate results, Ringbom optimum concentration ranges was 0.5–2.7 μg mL?1. The apparent molar absorbtivity and Sandell sensitivity were calculated. The validity of the proposed method was tested by analyzing the pure and pharmaceutical formulations and compared well with those obtained by the official method and demonstrated good accuracy and precision.  相似文献   

17.
The determination of uric acid in urine shows clinical importance, once it can be related to human organism dysfunctions, such as gout. An analytical procedure employing a multicommuted flow system was developed for the determination of uric acid in urine samples. Cu(II) ions are reduced by uric acid to Cu(I) that can be quantified by spectrophotometry in the presence of 2,2′-biquinoline 4,4′-dicarboxylic acid (BCA). The analytical response was linear between 10 and 100 μmol L− 1 uric acid with a detection limit of 3.0 μmol L− 1 (99.7% confidence level). Coefficient of variation of 1.2% and sampling rate of 150 determinations per hour were achieved. Per determination, 32 μg of CuSO4 and 200 μg of BCA were consumed, generating 2.0 mL of waste. Recoveries from 91 to 112% were estimated and the results for 7 urine samples agreed with those obtained by the commercially available enzymatic kit for determination of uric acid. The procedure required 100-fold dilution of urine samples, minimizing sample consumption and interfering effects. In order to avoid the manual dilution step, on-line sample dilution was achieved by a simple system reconfiguration attaining a sampling rate of 95 h− 1.  相似文献   

18.
A highly efficient single-drop microextraction (SDME) procedure using a low-cost room temperature ionic liquid (RTIL), i.e., tetradecyl(trihexyl)phosphonium chloride (CYPHOS® IL 101), for Pb determination at trace levels in real water samples was developed. Lead was chelated with 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP) reagent and extracted into a 4 μL microdrop of CYPHOS® IL 101. The RTIL drop was directly injected into the graphite furnace of the electrothermal atomic absorption spectrometer (ETAAS). Under optimal microextraction conditions, a preconcentration factor of 32 was achieved with only 1.5 mL of sample resulting in a phase-volume ratio of 375. The limit of detection (LOD) obtained was 3.2 ng L−1 and the relative standard deviation (RSD) for 10 replicates at 0.5 μg L−1 Pb2+ concentration level was 4.9%, calculated at peak heights. The calibration graph was linear from concentration levels near the detection limits up to at least 4.5 μg L−1 with a correlation coefficient of 0.9996. The accuracy of the methodology was evaluated by analysis of a certified reference material (CRM). The method was successfully applied to the determination of Pb in tap, mineral, well and river water samples.  相似文献   

19.
This paper describes the synthesis of a molecularly imprinted polymer by chemical oxidation of pyrrole as the functional monomer, and at the presence of guaifenesin as the template. The prepared polymer was used as adsorbent in molecularly imprinted solid‐phase extraction followed by spectrophotometric determination. Different parameters in the solid‐phase extraction including sample pH, adsorbent weight, washing solution, and elution solvent were studied to determine optimum conditions for isolation and enrichment of guaifenesin. The results showed guaifenesin was quantitatively adsorbed on the molecularly imprinted polymer at pH 6.0 and completely eluted with an ethanol–water solution (50% v/v). An enrichment factor of four with satisfactory recoveries (87.0–95.0%) was obtained. The solid‐phase extraction columns could be used for up to six consecutive elution‐loading cycles without significant decreases in the analyte recoveries. The method had a dynamic range of 3.0 × 10?6–1.5 × 10?4 mol/L with a limit of detection and limit of quantification of 1.4×10?6 and 4.5×10?6 mol/L, respectively. The proposed procedure was used for the extraction and determination of guaifenesin in different pharmaceutical formulations, with satisfying results being achieved.  相似文献   

20.
 A potentiometric flow injection method for the determination of anionic polyelectrolytes utilizing a flow-through type surfactant-selective electrode detector is described. The method is based on the detection of the concentration increase of anionic surfactant liberated from a reagent stream containing an ion associate between cationic polyelectrolyte, poly(diallyldimethylammonium chloride) and anionic surfactant, dodecylbenzenesulfonate, which is caused by the formation of a polyion complex between cationic and anionic polyelectrolytes. The response of the electrode detector as a peak-shaped signal was obtained for injected anionic polyelectrolyte samples. A linear relationship was found to exist between peak height and the logarithmic concentration of potassium poly (vinyl sulfate) (PVSK) with a slope of 30 mV decade-1 in a concentration range of 1.0×10-4 to 1.0×10-3 mol/L. Identical relationships were obtained for sodium alginate and carageenan (also anionic polyelectrolytes) as for PVSK but with a lower sensitivity. The detection limit for PVSK was 2.5×10-5 mol/L. The relative standard deviation for 5 injections of a 2.5×10-4 mol/L PVSK solution was 1.3% and the sampling rate was ca. 10 samples h-1. Received: 9 April 1996/Revised: 8 July 1996/Accepted: 14 July 1996  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏