首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
A new method of SS-RTP for the determination of trace silver has been established. This method is based on the fact that Ag+, when activated by ,-bipyridyl (bipy) in a media of HAc–NaAc (pH=4.9), can catalyze the reaction of Rhodamine B (RhoB) oxidized by K2S2O8, thus causing the Solid Substrate Room-Temperature Phosphorescence (SS-RTP) of RhoB to be quenched. The activating efficiency of bipy is 6.7 times higher than that of o-phenanthroline (phen). The reduction of the phosphorescence intensity (Ip) of RhoB is directly proportional to the concentration of Ag+ ions in the range of 1.6016.0agspot–1 (0.40µLspot–1). The regression equation of the working curve can be expressed as Ip=18.78+5.100mAg+ (agspot–1) (r=0.9994, n=6), the detection limit is 0.28agspot–1. This rapid, accurate and sensitive method has been successfully applied to the determination of trace silver in tea and human hair samples, and the results agree well with the Atomic Absorption Spectroscopy (AAS) method. The mechanism of the catalyzing reaction is also discussed.  相似文献   

2.
Two procedures for wet decomposition of human hair samples were compared for selenium determination by hydride generation atomic absorption spectrometry (HGAAS). These procedures involve treatment with HNO3/H2O2 and H2SO4/HNO3, respectively, using small disposable polypropylene (PP) vials. Analytical steps from weighing to dilution were performed in the same individual PP vial. After sample weighing (10±3mg) and reagent addition, decomposition was performed in a conventional oven (20h, 100°C). Addition of sulfamic acid prior to HGAAS measurements was necessary to minimize interference due to residual nitrogen oxides from the decomposition step. The accuracy was estimated using certified hair reference analysis which yielded an agreement higher than 97% (recovery tests). The absolute limit of detection was 1.2ng (3 s; n=10), corresponding to 0.12µgg–1 in the dry sample.  相似文献   

3.
A novel method for the determination of proteins in aqueous solutions has been developed based on the enhancement of resonance light scattering (RLS) of Ag nanoparticles in the presence of proteins. Factors including acidity of the media, concentration of Ag hydrosol, reaction time, temperature, and interference of non-protein substances were investigated. Under the optimal conditions, with the enhanced RLS signals at 452nm, the linear ranges of calibration curves were 0–0.8µgmL–1 for bovine serum albumin (BSA), 0–1.2µgmL–1 for human serum albumin (HSA), and 0–2.5µgmL–1 for human -IgG (-IgG), respectively. The detection limits were 1.3ngmL–1 for BSA, 10ngmL–1 for HAS, and 5.7ngmL–1 for -IgG.This method has been applied to the analysis of synthetic samples and real human serum samples, and the results were in good agreement with those reported by the hospital, indicating that the method presented here is not only sensitive and simple, but also reliable and suitable for practical applications.  相似文献   

4.
A simple and novel electrogenerated chemiluminescence (ECL) method for the determination of sulfite has been developed based on the energy transfer ECL process. It was found that a weak ECL signal of sulfite was electrochemically generated on a platinum electrode in neutral aqueous solution. The signal was strongly enhanced by rhodamine B as an energy receptor and further enhanced by the neutral surfactant Tween 80. In 0.10M phosphate buffer solution (pH=7.5) containing 2.0×10–6gmL–1 rhodamine B and 0.4% (v/v) Tween 80, the ECL response to the concentration of sulfite at a potential of 0.82V was linear over a range of 1.0×10–7gmL–1 to 8.0×10–6gmL–1, and the detection limit was 5×10–8gmL–1. The relative standard deviation (n=11, 1.0×10–6gmL–1) was 3.8%. The proposed method has been successfully applied to the determination of sulfite in pharmaceutical injections and white sugar samples.  相似文献   

5.
A method for the determination of trace amounts of arsenic in food samples using flow injection analysis and atomic absorption spectrometry with hydride generation (FI-HG AAS) was developed. The parameters of the flow injection system and the hydride generation were optimized with respect to reagent concentrations, atomization temperature, injection volume, reaction coil length and carrier flow rate. The limits of detection and quantification were 0.34µgL–1 and 1.2µgL–:1, respectively, and the analytical curve is linear up to 30.0µgL–1 arsenic. The relative standard deviation for 12 replicates varies between 5% for 4.0µgL–1 As and 1.8% for 30.0µgL–1 As, with an injection frequency of up to 135h–1. Interferences from Ni(II), Cu(II), Fe(III), Cr(III), Mo(II), Bi(III), Se(IV), Se(VI), Sb(III) and Sb(V) could be masked with a mixture of ascorbic acid-KI in a 5.0molL–1 HCl solution. The accuracy of the proposed method was evaluated by using certified reference materials of biological samples, and the method was used to determine the content of arsenic in fish and coffee beans.  相似文献   

6.
Brightness reversion of softwood (SW) and hardwood (HW) bleached chemithermomechanical pulps (BCTMP) with a 300–400nm light source under argon, oxygen, and air were studied in the absence and presence of UV-screens using UV–Vis reflectance difference spectroscopy. The UV-Vis difference absorption spectra of control SW and HW BCTMP testsheets indicate that as the concentration of atmospheric oxygen is increased, the absorption at max 360nm increases and a blue shift occurs. In all of the cases studied, brightness reversion was observed to occur under an argon atmosphere. The addition of benzophenone and benzotriazole additives to BCTMP testsheets resulted in a significant decrease in formation of chromophores absorbed at 400nm and 360nm. The possible mechanisms contributing to these effects are discussed in terms of the photoformation of lignin chromophoric structures.  相似文献   

7.
A sensitive and selective solid phase spectrophotometric method for the determination of trace amounts of inorganic mercury is described. Hg2+ was sorbed on a silica gel-packed column as an Hg2+N,N-bis(2-mercaptophenyl)ethanediamide (H2L) complex. The Hg2+ complex was eluted from the column using 7mL of acetone. Various parameters including pH, column flow rate, and ligand concentration were optimized. The complex was found to obey Beers law from 2.3 to 73.7µgmL–1 within the optimum range when the preconcentration factor was two. The effective molar absorption coefficient at 523nm was 1.17×103Lmol–1cm–1 at 523nm. The concentration limits in Beers law dropped from 0.09 to 2.95µgmL–1 within the optimum range when the preconcentration factor was 50. The relative standard deviation at a concentration level of 5µgmL–1 Hg2+ (9 repetitive determinations) was 1.6%. The detection limits are 0.34µgmL–1 and 0.015µgmL–1 when the preconcentration factors are 2 and 50, respectively. The method has been used for routine determination of trace levels of Hg2+ in natural waters. The potential application of this method for the removal of Hg2+ from natural samples (sea water and lake water) spiked with 100ngmL–1 of Hg2+ was studied. In order to validate the proposed method, LGC 6156 (harbour sediment – extractable metals) was analysed by this method. The results proved that excellent extraction of Hg2+ from both natural water samples was obtained by solid phase extraction using N,N-bis(2-mercaptophenyl) ethanediamide.  相似文献   

8.
A spectrophotometric method for the selective determination of Al(III) in the presence of Be and Ln (lanthanide) cations is proposed. It is based on the selective reaction of SXO (Semi-Xylenol Orange) with Al(III) at pH 2.6. The presence of 8%v/v of 1,2-ethanediol serves to stabilize the chelate formed by heating at 100°C for 5min. 0.5mg each of Be(II), Ce(III), La(III), 4mg of Mn(II), 1.2mg of Pb(II), 1mg of Tl(I), 40mg each of Ca(II) and Mg(II) and 1.9mg of sodium dihydrogen phosphate are tolerable. A ligand buffer of HEDTA-Pb is incorporated to further enhance the selectivity of the color reaction. Under the specified conditions SXO reacts with Al(III) to form a 1:1 chelate. Its molar absorptivity at 526nm was found to be 3.3×104Lmol–1cm–1. The linear regression equation for 2–20µg of Al(III) is A=0.04458C+0.0112 (where C stands for the concentration of Al(III), µg per 25mL) and correlation coefficient =0.9988. The RSD at the level of 10µg (n=10) and LOQ were found to be 3.5% and 2µg, respectively.  相似文献   

9.
A novel functionalized polyvinyl alcohol keto-derivative nanoparticle (PVAK) has been prepared in a one-step method using oxidation and degradation under ultrasonic irradiation. The nanoparticle is water-soluble, chemically stable, non-toxic and biocompatible. The surface of the nanoparticle is covered with abundant hydroxyl, carbonyl and carboxyl. At pH 3.0, the interactions of PVAK with different proteins can result in obviously enhanced RLS signals at 380nm. Under optimal conditions, the calibration graphs are linear over the range of 0.024.0µgmL–1 for human serum albumin (HSA), 0.023.5µgmL–1 for bovine serum albumin (BSA), and 0.053.5µgmL–1 for human -globulin (-G), respectively. Detection limits were 6.4ngmL–1 for HSA, 9.2ngmL–1 for BSA, and 12.5ngmL–1 for -G, respectively. The method was employed for the determination of total proteins in human serum with satisfactory results.  相似文献   

10.
Thallium in natural water samples was determined by electrothermal atomic absorption spectrometry after 1000-fold enrichment by mini solid-phase extraction from a 100-mL sample solution. A Tl-pyrrolidine-1-carbodithioate complex formed in a sample solution of pH 1.6 was extracted on fine particles of a cellulose nitrate resin dispersed in the sample solution. The cellulose nitrate resin was then collected on a membrane filter (25mmø) by filtration under suction using a glass funnel with an effective filtration area of 0.64cm2. As a result, a circular thin layer of the resin phase with a diameter of 9mm was obtained. Then the resin phase was carved out by an acrylate resin puncher with a 10-mmø hole to put it into a sample cup containing 100µL of 10mM HNO3 containing 0.5mM NaCl. The resin phase was suspended in the solution by ultrasonication. 1000-fold enrichment was thus attained within 15min, and the suspension was delivered to electrothermal atomic absorption spectrometry. The linear calibration graph was obtained in the range of 0–4ng of Tl in 100mL of a sample solution. The detection limit obtained by 3 method was 0.19ng. The proposed method was applied to the determination of Tl in natural water samples. The results showed the concentration of Tl in seawater was 12.1±1.8pgmL–1 for the calibration graph method and 12.6±1.4pgmL–1 for the standard addition method. A snowmelt sample contained 20.7±1.0pgmL–1 of Tl.  相似文献   

11.
The fabrication and electrochemical characteristics of a penicillamine (PCA) self-assembled monolayer modified gold electrode were investigated. The self-assembled electrode shows obvious electrocatalytic activity for the oxidation of epinephrine (EP). In phosphate buffer (pH 7.73), a sensitive oxidation peak was observed at 0.190V with the PCA modified Au electrode. The peak current is proportional to the concentration of EP in the range of 2.0×10–56.0×10–4molL–1 and 5.0×10–6 2.0×10–4molL–1 for cyclic voltammetry (CV) and differential pulse voltammetry (DPV) with the detection limits of 1.8×10–7 and 1.3×10–7molL–1, respectively. The possible reaction mechanism is also discussed. The PCA self-assembled monolayer modified gold electrode is highly stable and can be applied to the determination of EP in practical injection samples. Application is simple, rapid and produces accurate results.  相似文献   

12.
A simple commercial graphite pencil electrode (GPE) was utilized for monitoring caffeine using the square-wave anodic stripping voltammetry (SWASV) method. This method was applied to determine the caffeine levels in several tea samples, which yielded a relative error of 1% in the concentrations. Caffeine was deposited at 0.0V (vs. Ag/AgCl), then reduced at +1.40V to strip it on the GPE. Optimal experimental conditions for the analysis were found to be as follows: pH value of 9 for the medium; deposition potential of 0.0V; deposition time of 120s; SW frequency of 25Hz; SW amplitude of 45mV, and step potential of 6mV. Given these optimum conditions, a linear range was observed within the concentration of 0500mgL–1. At caffeine concentrations of 50.0, 250.0, and 500.0mgL–1, the relative standard deviations in measured concentrations (n=12) were 0.19, 0.09, and 0.11%, respectively. The detection limit was found to be 9.2mgL–1, which is comparable with the result obtained using a carbon paste electrode, equivalent to 8.2mgL–1.  相似文献   

13.
A microcolumn on-line preconcentration and separation system was developed for the flame atomic absorption spectrometric (FAAS) determination of trace levels of gold and palladium. The analytes were selectively adsorbed onto the microcolumn packed with 2-mercaptothiazole immobilized silica gel (MBTSG) in an acidity range of 0.1 to 6.0M HCl at a sampling flow rate of 4.0mLmin–1. The analytes adsorbed could be desorbed by a thiourea solution with a flow rate of 2.0mLmin–1. Most of the common coexisting metal ions at a concentration of 25.0mgmL–1 and anions at a concentration of 50.0mgmL–1 did not interfere with the preconcentration and determination of Au and Pd. The limits of detection (LOD), defined as three times the standard deviation of the blank (3), of Au and Pd are 10ngmL–1 and 26ngmL–1, respectively, with a preconcentration time of 60s. The relative standard deviation (RSD) is about 2.0% for 0.20µgmL–1 Au and 0.30µgmL–1 Pd. With a sample loading time of 30min, 6.7ngmL–1 Au and 10ngmL–1 Pd can be preconcentrated quantitatively. A geological sample, an anode slime and a secondary nickel alloy were successfully determined with the proposed method, and the results obtained showed good agreement with the certified values.Received December 23, 2002; accepted May 14, 2003 Published online August 8, 2003  相似文献   

14.
A new method for the simultaneous determination of heavy metal ions in Chinese herbal medicine by microwave digestion and reversed-phase high-performance liquid chromatography (RP-HPLC) has been developed. The Chinese herbal medicine samples were digested by microwave digestion. Lead, cadmium, mercury, nickel, copper, zinc, and tin ions in the digested samples were pre-column derivatized with tetra-(4-chlorophenyl)-porphyrin (T4-CPP) to form the colored chelates which were then enriched by solid phase extraction with C18 cartridge and eluted from the cartridge with tetrahydrofuran (THF). The chelates were separated on a Waters Xterra RP18 column by gradient elution with methanol (containing 0.05molL–1 pyrrolidine-acetic acid buffer salt, pH=10.0) and THF (containing 0.05molL–1 pyrrolidine-acetic acid buffer salt, pH=10.0) as mobile phase at a flow rate of 0.5mLmin–1 and detected with a photodiode array detector in the range of 350–600nm. In the original samples the detection limits of lead, cadmium, mercury, nickel, copper, zinc and tin are 4ngL–1, 3ngL–1, 6ngL–1, 5ngL–1, 2ngL–1, 6ngL–1, and 4ngL–1, respectively. This method was applied to the determination of lead, cadmium, mercury, nickel, copper, zinc and tin in Chinese herbal medicine samples with good results.  相似文献   

15.
Osmocene (and decamethylosmocene) is characterized by a lowest-energy ligand field triplet which occurs at max=372nm (374nm) in absorption and 567nm (572nm) in emission. This orange–yellow phosphorescence is rather intense at 77K but is also visible at r.t.  相似文献   

16.
This study aims to investigate the distribution of Na, K, Rb and Cs in human brains (5 individuals, 12 brain parts, mean age: 75 years). Distribution of the trace metals between lipid fraction and brain tissue was investigated in solvent extraction experiments. Determinations were carried out by instrumental neutron activation analysis. The present results show a rather non-homogeneous distribution for Na and a relatively uniform distribution for K, Rb and Cs. The mean concentrations found are 7440µgNag–1 dry weight, 12800µgKg–1, 14µgRbg–1 and 50ngCsg–1. A highly significant positive correlation was found between Rb and Cs. Solvent extraction experiments showed that 19% of Rb and 26% of Cs of the total content is located in lipid fraction.  相似文献   

17.
A single-wall carbon nanotubes (SWNT) film coated glassy carbon electrode (GCE) was fabricated for the direct determination of 4-nitrophenol (4-NP). The electrochemical behaviors of 4-NP at the SWNT-film coated GCE were examined. In 0.1M phosphate buffer with a pH of 5.0, 4-NP yields a very sensitive and well-defined reduction peak at the SWNT-modified GCE. It is found that the SWNT film exhibits obvious electrocatalytic activity towards the reduction of 4-NP since it not only increases the reduction peak current but also lowers the reduction overpotential. Based on this, an electrochemical method was proposed for the direct determination of 4-NP. The reduction peak current varies linearly with the concentration of 4-NP ranging from 1×10–8 to 5×10–6M, and the detection limit is 2.5×10–9M after 3min of open-circuit accumulation. The relative standard deviation at 2×10–7M 4-NP was about 6% (n=10), suggesting excellent reproducibility. This new method was successfully employed to determine 4-NP in several lake water samples.  相似文献   

18.
A carbon black microelectrode modified by -MnO2 has been prepared. The electrocatalytical oxidation of ascorbic acid (AA) at this microelectrode was investigated. The 2nd-order linear scan voltammograms of AA are recorded from –0.5 to 0.5V (vs. SCE). The relationship between the oxidation peak current of AA and its concentration in the range of 1.0×10–64.0×10–3molL–1 is linear. The detection limit (3) was found to be 6.0×10–7molL–1. Also, the determination of AA in samples is evaluated, and the results are satisfactory.  相似文献   

19.
A new approach, based on non-aqueous capillary electrophoresis separation and indirect photometric detection, was established for the determination of the transition metal ions Pb2+, Zn2+ and Cd2+. Under optimized conditions, the method produced baseline separation of these three metal ions. The linear range and detection limits were 1050µM, 1.9µM for Cd2+; 1050µM, 2.1µM for Zn2+; and 20100µM, 3.8µM for Pb2+, respectively.  相似文献   

20.
Speciation of arsenic in environmental samples gains increasingly importance, as the toxic effects of arsenic are related to its oxidation state. A method was developed for the determination of trace amounts of arsenic(III) and total arsenic by flow injection hydride generation coupled with an in-house made non-dispersive AAS device. The total arsenic is determined after prereduction of arsenic(V) to arsenic(III) with L-cysteine in a low concentration of hydrochloric, acetic or nitric acid. The conditions for the prereduction, hydride generation and atomization were systematically investigated. A quartz tube temperature of 800°C was found to be optimum in view of peak shape and baseline stability. Pb(II), Ni(II), Fe(III), Cu(II), Ag(I), Al(III), Ga(II), Se(IV), Bi(III) were checked for interfering with the 2g/L As(V) signal. A serious signal depression was only observed for Se(IV) and Bi(III) at a 150-fold excess. With the above system, arsenic was determined at a sampling frequency of about 1/min with a detection limit (3) of 0.01g/L using a 0.5mL sample. The reagent blank was 0.001±0.0003 absorbance units and the standard deviation of 10 measurements of the 2 g/l As signal was found to be 1.2%. Results obtained for standard reference materials and water samples are in good agreement with the certified values and those obtained by ICP-MS  相似文献   